HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: BILLIS RESIDENCE
Builder Name:
Street: 6113 BALSAM DRIVE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County. St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Types(2260.7 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 2102.00 ftz
b. Frame - Wood, Adjacent
R=11.0 158.67 ftz
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ftz
5. Is this a worst case?
No
11. Ceiling Types (2198.0 sgft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2198.00 ftz
6. Conditioned floor area above grade (ftz)
2198
b. N/A
R= ftz
Conditioned floor area below grade (ftz)
0
c. N/A
R= ftz
7. Windows(260.5 sgft.) Description
Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: AHU CLST
R ftz
6 175
a. U-Factor: Sgl, U=0.65
260.50 ftz
SHGC: SHGC=0.25
b. U-Factor: N/A
ftz
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
41.0 SEER:16.00
c. U-Factor: N/A
ftz
SHGC:
Area Weighted Average Overhang Depth:
4.741 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.250
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights
Area
c. U-Factor:(AVG) N/A
ftz
15. Hot water systems
SHGC(AVG): N/A
a. Natural Gas Tankless
Cap: 1 gallons
9. Floor Types (2198.0 sqft.)
Insulation Area
EF: 0.800
a. Slab -On -Grade Edge Insulation
R=0.0 2198.00 ftz
b. Conservation features
b. N/A
R= ftz
None
c. N/A
R= ftz
16. Credits
None
Glass/Floor Area: 0.119
Total Proposed Modified Loads: 66.96
PASS
Total Baseline Loads: 68.85
1 hereby certify that the plans and specifications covered by
Review of the plans and
T14E S A
this calculation are in compliance with the Florida Energy
specifications covered by this
4V = �0�,
Code.
calculation indicates compliance
Florida Energy Code.
!+ =';•'°. O
with the
nr�r,'w. •
PREPARED BY:
Before construction is completed
DATE.
this building will be inspected for
compliance with Section 553.908"
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
GOb
with the Florida Energy Code.
OWNER/AGENT'
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
F f•'i�, � � Iry"" i�f
8/16/2021 10:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
BILLIS RESIDENCE
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2198
Lot #
Owner Name:
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
6113 BALSAM DRIVE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Detached
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI,-
39
90
70
75
299
62
Low
BLOCKS
Number
Name .
Area
Volume
1
Entire House
2198
21025.4
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
M BATH
179
1664.7 No
0
1
Yes
Yes
Yes
2
MASTER•BEDROO
280
2884 No
0
1
1
Yes
Yes
Yes
3
M WIC
131
1218.3 No
0
1
Yes
Yes
Yes
4
PANTRY
63
588.9 No
0
1
No
Yes
Yes
5
HALLWAY
144
1339.2 No
0
1
No
Yes
Yes
6
LAUNDRY
84
781.2 No
0
1
Yes
Yes
Yes
7
MUD RM
64
595.2 No
0
1
Yes
Yes
Yes
8
AHU CLST
12
111.6 No
0
1
No
Yes
Yes
9
CLST 2
10
93 No
0
1
No
Yes
Yes
10
BEDROOM 2
160
1488 No
0
1
1
Yes
Yes
Yes
11
BATH 2
70
651 No
0
1
Yes
Yes
Yes
12
HALL
12
111.6 No
0
1
No
Yes
Yes
13
CLST3
14
130.2 No
0
1
No
Yes
Yes
14
BEDROOM 3
182
1692.6 No
0
1
1
Yes
Yes
Yes
15
FOYER
81
753.3 No
0
1
Yes
Yes
Yes
16
KITCHEN
240
2232 Yes
0
1
Yes
Yes
Yes
17
LIVING RM
304
3131.2 No
0
1
Yes
Yes
Yes
18
DINING RM
168
1562.4 No
0
1
Yes
Yes
Yes
8/16/2021 10:53 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
F-
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
M BATH
27 ft
179 ft2
____
1
0
0
2 Slab -On -Grade Edge Insulation
MASTER BEDRO 28 ft
280 ft2
_-__
1
0
0
3 Slab -On -Grade Edge Insulation
M W IC
loft
131 ft2
____
1
0
0
4 Slab -On -Grade Edge Insulation
PANTRY
1 ft
63 ft2
-__-
1
0
0
5 Slab -On -Grade Edge Insulation
HALLWAY
1 ft
144 ft2
____
1
0
0
6 Slab-O n-Grade Edge Insulation
LAUNDRY
9 ft
84 ft2
___
1
0
0
7 Slab -On -Grade Edge Insulation
MUD RM
7 ft
64 ft2
-__-
1
0
0
8 Slab -On -Grade Edge Insulation
AHU CLST
1 ft
12 ft2
___
1
0
0
9 Slab -On -Grade Edge Insulation
CLST 2
1 ft
10 ft2
__-_
1
0
0
10SIab-On-Grade Edge Insulation
BEDROOM 2
10 ft
160 ft2
__
1
0
0
11Slab-On-Grade Edge Insulation
BATH 2
5 ft
70 ft2
___-
1
0
0
12SIab-On-Grade Edge Insulation
HALL
1 ft
12 ft2
__
1
0
0
13SIab-On-Grade Edge Insulation
CLST3
1 ft
14 ft2
____
1
0
0
14SIab-On-Grade Edge Insulation
BEDROOM 3
19 ft
182 ft2
__
1
0
0
15SIab-On-Grade Edge Insulation
FOYER
18 ft
81 ft2
____
1
0
0
16SIab-On-Grade Edge Insulation
KITCHEN
15 ft
240 ft2
___-
1
0
0
17SIab-On-Grade Edge Insulation
LIVING RM
30 ft
304 ft2
___
1
0
0
18SIab-On-Grade Edge Insulation
DINING RM
41 ft
168 ft2
____
1
0
0
ROOF
/
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
v # Type Materials
Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 2458 ft2
0 ft2 Light
N
0.3 No 0.9
No
20
26.57
ATTIC
IRCC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS
1 Full attic
Unvented
0
2198 ft2
N N
8/16/2021 10:53 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (U nvented) MBATH
0
Blown
179ft2
0.1
Wood
2
Under Attic (Unvented) MASTER BEDRO 0
Blown
280 ftz
0.1
Wood
3
Under Attic (Unvented) M WIC
0
Blown
131 ftz
0.1
Wood
4
Under Attic (Unvented) PANTRY
0
Blown
63 ftz
0.1
Wood
5
Under Attic (Unvented) HALLWAY
0
Blown
144 ftz
0.1
Wood
6
Under Attic (U nvented) LAUNDRY
0
Blown
84ft2
0.1
Wood
7
Under Attic (Unvented) MUD RM
0
Blown
64ft2
0.1
Wood
8
Under Attic (Unvented) AHU CLST
0
Blown
12ftz
0.1
Wood
9
Under Attic (Unvented) CLST 2
0
Blown
10 ftz
0.1
Wood
10
Under Attic (Unvented) BEDROOM 2
0
Blown
160 ftz
0.1
Wood
11
Under Attic (Unvented) BATH 2
0
Blown
70 ftz
0.1
Wood
12
Under Attic (Unvented) HALL
0
Blown
12 ftz
0.1
Wood
13
Under Attic (Unvented) CLST3
0
Blown
14 ftz
0.1
Wood
14
Under Attic (Unvented) BEDROOM 3
0
Blown
182 ftz
0.1
Wood
15
Under Attic (Unvented) FOYER
0
Blown
81 ftz
0.1
Wood
16
Under Attic (U nvented) KITCHEN
0
Blown
240ft2
0.1
Wood
17
Under Attic (Unvented) LIVING RM
0
Blown
304 ftz
0.1
Wood
18
Under Attic (Unvented) DINING RM
0
Blown
168 ftz
0.1
Wood
WALLS
Adjacent Space
Cavity
Width
Height
Sheathing Framing Solar
Below
_ 1
N
Exterior Concrete Block- Int Insul M BATH
4.1
16
0 9
4
149.3 ftz
0
0
0.3
0
2
W
Exterior Concrete Block- Int Insul M BATH
4.1
11
0 9
4
102.7 ftz
0
0
0.3
0
3
S
Exterior Concrete Block - Int InsuMASTER BE
4.1
12
0 10
4
124.0 ftz
0
0
0.3
0
4
W
Exterior Concrete Block - Int InsuMASTER BE
4.1
16
0 10
4
165.3 ftz
0
0
0.3
0
5
N
Exterior Concrete Block- Int Insul M W IC
4.1
10
0 9
4
93.3 ftz
0
0
0.3
0
_ 6
E
Garage Frame - Wood HALLWAY
11
4
0 9
4
37.3 ftz
0
0.1
0.3
0
7
N
Exterior Concrete Block - Int Insul LAUNDRY
4.1
9
0 9
4
84.0 ftz
0
0
0.3
0
8
N
Exterior Concrete Block - Int Insul MUD RM
4.1
7
0 9
4
65.3 ftz
0
0
0.3
0
9
E
Garage Frame - Wood MUD RM
11
10
0 9
4
93.3 ftz
0
0.1
0.3
0
10
E
Exterior Concrete Block- Int InsuBEDROOM 2
4.1
10
0 9
4
93.3 ftz
0
0
0.3
0
11
E
Garage Frame - Wood BEDROOM 2
11
3
0 9
4
28.0 ftz
0
0.1
0.3
0
12
E
Exterior Concrete Block - Int Insul BATH 2
4.1
5
0 9
4
46.7 ftz
0
0
0.3
0
13
E
Exterior Concrete Block - Int InsuBEDROOM 3
4.1
14
0 9
4
130.7 ftz
0
0
0.3
0
14
S
Exterior Concrete Block - Int InsuBEDROOM 3
4.1
5
0 9
4
46.7 ftz
0
0
0.3
0
15
E
Exterior Concrete Block- Int Insul FOYER
4.1
9
0 9
4
84.0 ftz
0
0
0.3
0
16
S
Exterior Concrete Block- Int Insul FOYER
4.1
9
0 9
4
84.0 ftz
0
0
0.3
0
17
W
Exterior Concrete Block- Int Insul KITCHEN
4.1
15
0 9
4
140.0 ftz
0
0
0.3
0
18
E
Exterior Concrete Block- Int Insul LIVING RM
4.1
6
0 10
4
62.0 ftz
0
0
0.3
0
19
S
Exterior Concrete Block - Int Insul LIVING RM
4.1
16
0 10
4
165.3 ftz
0
0
0.3
0
20
W
Exterior Concrete Block - Int Insul LIVING RM
4.1
8
0 10
4
82.7 ftz
0
0
0.3
0
21
N
Exterior Concrete Block - Int InsulDINING RM
4.1
12
0 9
4
112.0 ftz
0
0
0.3
0
22
E
Exterior Concrete Block - Int InsulDINING RM
4.1
3
0 9
4
28.0 ftz
0
0
0.3
0
8/16/2021 10:53 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY GNEGKL.I5T REPORT
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Below
iornt 10 Wall Type SpaceR,-Va'11e Et In Pt in Are-o
23 S Exterior Concrete Block - Int InsulDINING RM 4.1 12 0 9 4 112.0 ft2 0 0 0.3 0
_24 W Exterior Concrete Block- Int InsulDINING RM 4.1 14 0 9 4 130.7 ft2 0 0 0.3 0
DOORS
V # Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E Insulated FOYER None .23 3 7 21 ft2
WINDOWS
V
Wall
#
Ornt
ID
Frame
Panes
_ 1
N
1
Metal
Low-E Single
2
W
2
Metal
Low-E Single
_ 3
S
3
Metal
Low-E Single
4
W
4
Metal
Low-E Single
_ 5
N
7
Metal
Low-E Single
_ 6
N
8
Metal
Low-E Single
_ 7
E
10
Metal
Low-E Single
_ 8
E
12
Metal
Low-E Single
9
E
13
Metal
Low-E Single
10
S
14
Metal
Low-E Single
11
E
15
Metal
Low-E Single
_ 12
W
17
Metal
Low-E Single
13
E
18
Metal
Low-E Single
14
S
19
Metal
Low-E Single
_ 15
W
20
Metal
Low-E Single
16
S
23
Metal
Low-E Single
17
W
24
Metal
Low-E Single
# Floor Area
1 832 ft2
Ceiling A
832 ft2
NFRC U-Factor SHGC
Yes
rea_
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
GARAGE
Exposed Wall Perimeter
17 ft
INFILTRATION
Overhang
:np
Area
Depth
Separatic
Y
16.0 ft2
2 ft 0 in
1 ft 4 in
Y
8.0 ft2
2 ft 0 in
1 ft 4 in
Y
21.0ft2
2ft0in
1ft4in
Y
16.0 ft2
2 ft 0 in
1 ft 4 in
Y
12.0 ft2
2 ft 0 in
1 ft 4 in
Y
8.0 ft2
2 ft 0 in
1 ft 4 in
Y
15.0 ft2
2 ft 0 in
1 ft 4 in
Y
4.0 ft2
2 ft 0 in
1 ft 4 in
Y
15.0 ft2
2 ft 0 in
1 ft 4 in
Y
8.0 ft2
2 ft 0 in
1 ft 4 in
Y
14.0 ft2
2 ft 0 in
1 ft 4 in
Y
17.5ft2
14ft0in
1ft4in
Y
8.0 ft2
2 ft 0 in
1 ft 4 in
Y
24.0 ft2
2 ft 0 in
1 ft 4 in
Y
42.0 ft2
14 ft 0 in
1 ft 4 in
Y
16.0 ft2
2 ft 0 in
1 ft 4 in
Y
16.0 ft2
2 ft 0 in
1 ft 4 in
Wall
9 ft
Int Shade
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
Wall Insulation
11
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50) .000304 1752.1 96.13 180.47 .0969 5
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
8/16/2021 10:53 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat/
None
COP:1
27 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 16
41 kBtu/hr
1230 cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Natural Gas Tankless
Garage
0.8 1 gal 55.1 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
-- Supply-- -
--- Return ---
Air
CFM 25
CFM25
HVAC #
v # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic 6 175 ft2
Attic
18 ft2 Default Leakage
AHU CLST
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan Feb Mar
HeatinJan Feb MarAPr
A r
Ma Jun [X Jul
Ma� Jun [ Jul
Au�Xj
rj Au
Se
SeP
Oct Nov
Oct Nov
HX
Dec
Dec
H
Ventin Jan Feb X Mar
A r
[ Ma [ Jun [ Jul
l l
Aug
Se
Oct Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8
9
10 11
12
Cooling (WD) AM 78
78 78
78 78 78
78
78
80
80 80
80
PM 80
80 80
80 78 78
78
78
78
78 78
78
Cooling (W EH) AM 78
78 78
78 78 78
78
78
80
80 80
80
PM 80
80 80
80 78 78
78
78
78
78 78
78
Heating (WD) AM 65
65 65
65 65 65
65
68
68
68 68
68
PM 68
68 68
68 68 68
68
68
68
68 68
68
Heating (W EH) AM 65
65 65
65 65 65
65
68
68
68 68
68
PM 68
68 68
68 68 68
68
68
68
68 68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
-
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MUD RM
Default(8lbs/sq.ft.
ft2
ft
0.3
AHU CLST
8/16/2021 10:53 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST3
Default(8 Ibs/sq.ft.
f?
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVING RM
Default(8 Ibs/s .ft.
f?
ft
0.3
DINING RM
8/16/2021 10:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX' = 97
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows-
Description
a. U-Factor:
Sgl, U=0.65
SHGC:
SHGC=0.25
b. U-Factor:
N/A
SHGC:
c. U-Factor:
N/A
SHGC:
d. U-Factor:
NIA
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights
Description
a. U-Factor(AVG):
N/A
SHGC(AVG):
N/A
6113 BALSAM DRIVE, FORT PIERCE, FL,
New (From Plans)
Detached
1
3
No
2198
Area
260.50 ftz
ftz
ftz
ftz
4.741 ft.
0.250
Area
ftz
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 2198.00 ftz
b. N/A R= ftz
c. NIA R= ftz
10. Wall Type and Insulation
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
c. N/A
d. NIA
11. Ceiling Type and insulation level
a. Roof Deck (Unvented)
b. N/A
c. N/A
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Attic, AH: AHU CLST
13. Cooling systems
a. Central Unit
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Natural Gas
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Q ^ /L Date:
/7���L/ ` 8 ^ 2Q z-f
Address of New Home: ��3��� �- City/FL Zip: �. F /, eec� ,3 �(� 8
Insulation Area
R=4.1 2102.00 ftz
R=11.0 158.67 ftz
R=
ftz
R=
ftz
Insulation
Area
R=20.0
2198.00 ftz
R=
ftz
R=
ftz
R ftz
6 175
kBtu/hr
Efficiency
41.0
SEER:16.00
kBtu/hr Efficiency
27.0 COP:1.00
Cap: 1 gallons
EF: 0.8
None
�yoI-T1AE srAT�o��
DDWE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8/16/2021 10:54 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: BILLIS RESIDENCE Builder Name:
Street: 6113 BALSAM DRIVE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
U
Owner: Jurisdiction: ST LUCIE COUNTY
W
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind plOna and wiring.
Showerltub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub -floor, wall covering or ceiling
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
8/16/2021 10:54 AM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1