HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BILLIS RESIDENCE Builder Name: Street: 6113 BALSAM DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Types(2260.7 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 2102.00 ftz b. Frame - Wood, Adjacent R=11.0 158.67 ftz 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ftz 5. Is this a worst case? No 11. Ceiling Types (2198.0 sgft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2198.00 ftz 6. Conditioned floor area above grade (ftz) 2198 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 7. Windows(260.5 sgft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: AHU CLST R ftz 6 175 a. U-Factor: Sgl, U=0.65 260.50 ftz SHGC: SHGC=0.25 b. U-Factor: N/A ftz 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 41.0 SEER:16.00 c. U-Factor: N/A ftz SHGC: Area Weighted Average Overhang Depth: 4.741 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ftz 15. Hot water systems SHGC(AVG): N/A a. Natural Gas Tankless Cap: 1 gallons 9. Floor Types (2198.0 sqft.) Insulation Area EF: 0.800 a. Slab -On -Grade Edge Insulation R=0.0 2198.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 16. Credits None Glass/Floor Area: 0.119 Total Proposed Modified Loads: 66.96 PASS Total Baseline Loads: 68.85 1 hereby certify that the plans and specifications covered by Review of the plans and T14E S A this calculation are in compliance with the Florida Energy specifications covered by this 4V = �0�, Code. calculation indicates compliance Florida Energy Code. !+ =';•'°. O with the nr�r,'w. • PREPARED BY: Before construction is completed DATE. this building will be inspected for compliance with Section 553.908" I hereby certify that this building, as designed, is in compliance Florida Statutes. GOb with the Florida Energy Code. OWNER/AGENT' BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). F f•'i�, � � Iry"" i�f 8/16/2021 10:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: BILLIS RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2198 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 6113 BALSAM DRIVE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI,- 39 90 70 75 299 62 Low BLOCKS Number Name . Area Volume 1 Entire House 2198 21025.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M BATH 179 1664.7 No 0 1 Yes Yes Yes 2 MASTER•BEDROO 280 2884 No 0 1 1 Yes Yes Yes 3 M WIC 131 1218.3 No 0 1 Yes Yes Yes 4 PANTRY 63 588.9 No 0 1 No Yes Yes 5 HALLWAY 144 1339.2 No 0 1 No Yes Yes 6 LAUNDRY 84 781.2 No 0 1 Yes Yes Yes 7 MUD RM 64 595.2 No 0 1 Yes Yes Yes 8 AHU CLST 12 111.6 No 0 1 No Yes Yes 9 CLST 2 10 93 No 0 1 No Yes Yes 10 BEDROOM 2 160 1488 No 0 1 1 Yes Yes Yes 11 BATH 2 70 651 No 0 1 Yes Yes Yes 12 HALL 12 111.6 No 0 1 No Yes Yes 13 CLST3 14 130.2 No 0 1 No Yes Yes 14 BEDROOM 3 182 1692.6 No 0 1 1 Yes Yes Yes 15 FOYER 81 753.3 No 0 1 Yes Yes Yes 16 KITCHEN 240 2232 Yes 0 1 Yes Yes Yes 17 LIVING RM 304 3131.2 No 0 1 Yes Yes Yes 18 DINING RM 168 1562.4 No 0 1 Yes Yes Yes 8/16/2021 10:53 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type F- Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation M BATH 27 ft 179 ft2 ____ 1 0 0 2 Slab -On -Grade Edge Insulation MASTER BEDRO 28 ft 280 ft2 _-__ 1 0 0 3 Slab -On -Grade Edge Insulation M W IC loft 131 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation PANTRY 1 ft 63 ft2 -__- 1 0 0 5 Slab -On -Grade Edge Insulation HALLWAY 1 ft 144 ft2 ____ 1 0 0 6 Slab-O n-Grade Edge Insulation LAUNDRY 9 ft 84 ft2 ___ 1 0 0 7 Slab -On -Grade Edge Insulation MUD RM 7 ft 64 ft2 -__- 1 0 0 8 Slab -On -Grade Edge Insulation AHU CLST 1 ft 12 ft2 ___ 1 0 0 9 Slab -On -Grade Edge Insulation CLST 2 1 ft 10 ft2 __-_ 1 0 0 10SIab-On-Grade Edge Insulation BEDROOM 2 10 ft 160 ft2 __ 1 0 0 11Slab-On-Grade Edge Insulation BATH 2 5 ft 70 ft2 ___- 1 0 0 12SIab-On-Grade Edge Insulation HALL 1 ft 12 ft2 __ 1 0 0 13SIab-On-Grade Edge Insulation CLST3 1 ft 14 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation BEDROOM 3 19 ft 182 ft2 __ 1 0 0 15SIab-On-Grade Edge Insulation FOYER 18 ft 81 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation KITCHEN 15 ft 240 ft2 ___- 1 0 0 17SIab-On-Grade Edge Insulation LIVING RM 30 ft 304 ft2 ___ 1 0 0 18SIab-On-Grade Edge Insulation DINING RM 41 ft 168 ft2 ____ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2458 ft2 0 ft2 Light N 0.3 No 0.9 No 20 26.57 ATTIC IRCC V # Type Ventilation Vent Ratio (1 in) Area RBS 1 Full attic Unvented 0 2198 ft2 N N 8/16/2021 10:53 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (U nvented) MBATH 0 Blown 179ft2 0.1 Wood 2 Under Attic (Unvented) MASTER BEDRO 0 Blown 280 ftz 0.1 Wood 3 Under Attic (Unvented) M WIC 0 Blown 131 ftz 0.1 Wood 4 Under Attic (Unvented) PANTRY 0 Blown 63 ftz 0.1 Wood 5 Under Attic (Unvented) HALLWAY 0 Blown 144 ftz 0.1 Wood 6 Under Attic (U nvented) LAUNDRY 0 Blown 84ft2 0.1 Wood 7 Under Attic (Unvented) MUD RM 0 Blown 64ft2 0.1 Wood 8 Under Attic (Unvented) AHU CLST 0 Blown 12ftz 0.1 Wood 9 Under Attic (Unvented) CLST 2 0 Blown 10 ftz 0.1 Wood 10 Under Attic (Unvented) BEDROOM 2 0 Blown 160 ftz 0.1 Wood 11 Under Attic (Unvented) BATH 2 0 Blown 70 ftz 0.1 Wood 12 Under Attic (Unvented) HALL 0 Blown 12 ftz 0.1 Wood 13 Under Attic (Unvented) CLST3 0 Blown 14 ftz 0.1 Wood 14 Under Attic (Unvented) BEDROOM 3 0 Blown 182 ftz 0.1 Wood 15 Under Attic (Unvented) FOYER 0 Blown 81 ftz 0.1 Wood 16 Under Attic (U nvented) KITCHEN 0 Blown 240ft2 0.1 Wood 17 Under Attic (Unvented) LIVING RM 0 Blown 304 ftz 0.1 Wood 18 Under Attic (Unvented) DINING RM 0 Blown 168 ftz 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 N Exterior Concrete Block- Int Insul M BATH 4.1 16 0 9 4 149.3 ftz 0 0 0.3 0 2 W Exterior Concrete Block- Int Insul M BATH 4.1 11 0 9 4 102.7 ftz 0 0 0.3 0 3 S Exterior Concrete Block - Int InsuMASTER BE 4.1 12 0 10 4 124.0 ftz 0 0 0.3 0 4 W Exterior Concrete Block - Int InsuMASTER BE 4.1 16 0 10 4 165.3 ftz 0 0 0.3 0 5 N Exterior Concrete Block- Int Insul M W IC 4.1 10 0 9 4 93.3 ftz 0 0 0.3 0 _ 6 E Garage Frame - Wood HALLWAY 11 4 0 9 4 37.3 ftz 0 0.1 0.3 0 7 N Exterior Concrete Block - Int Insul LAUNDRY 4.1 9 0 9 4 84.0 ftz 0 0 0.3 0 8 N Exterior Concrete Block - Int Insul MUD RM 4.1 7 0 9 4 65.3 ftz 0 0 0.3 0 9 E Garage Frame - Wood MUD RM 11 10 0 9 4 93.3 ftz 0 0.1 0.3 0 10 E Exterior Concrete Block- Int InsuBEDROOM 2 4.1 10 0 9 4 93.3 ftz 0 0 0.3 0 11 E Garage Frame - Wood BEDROOM 2 11 3 0 9 4 28.0 ftz 0 0.1 0.3 0 12 E Exterior Concrete Block - Int Insul BATH 2 4.1 5 0 9 4 46.7 ftz 0 0 0.3 0 13 E Exterior Concrete Block - Int InsuBEDROOM 3 4.1 14 0 9 4 130.7 ftz 0 0 0.3 0 14 S Exterior Concrete Block - Int InsuBEDROOM 3 4.1 5 0 9 4 46.7 ftz 0 0 0.3 0 15 E Exterior Concrete Block- Int Insul FOYER 4.1 9 0 9 4 84.0 ftz 0 0 0.3 0 16 S Exterior Concrete Block- Int Insul FOYER 4.1 9 0 9 4 84.0 ftz 0 0 0.3 0 17 W Exterior Concrete Block- Int Insul KITCHEN 4.1 15 0 9 4 140.0 ftz 0 0 0.3 0 18 E Exterior Concrete Block- Int Insul LIVING RM 4.1 6 0 10 4 62.0 ftz 0 0 0.3 0 19 S Exterior Concrete Block - Int Insul LIVING RM 4.1 16 0 10 4 165.3 ftz 0 0 0.3 0 20 W Exterior Concrete Block - Int Insul LIVING RM 4.1 8 0 10 4 82.7 ftz 0 0 0.3 0 21 N Exterior Concrete Block - Int InsulDINING RM 4.1 12 0 9 4 112.0 ftz 0 0 0.3 0 22 E Exterior Concrete Block - Int InsulDINING RM 4.1 3 0 9 4 28.0 ftz 0 0 0.3 0 8/16/2021 10:53 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY GNEGKL.I5T REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below iornt 10 Wall Type SpaceR,-Va'11e Et In Pt in Are-o 23 S Exterior Concrete Block - Int InsulDINING RM 4.1 12 0 9 4 112.0 ft2 0 0 0.3 0 _24 W Exterior Concrete Block- Int InsulDINING RM 4.1 14 0 9 4 130.7 ft2 0 0 0.3 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated FOYER None .23 3 7 21 ft2 WINDOWS V Wall # Ornt ID Frame Panes _ 1 N 1 Metal Low-E Single 2 W 2 Metal Low-E Single _ 3 S 3 Metal Low-E Single 4 W 4 Metal Low-E Single _ 5 N 7 Metal Low-E Single _ 6 N 8 Metal Low-E Single _ 7 E 10 Metal Low-E Single _ 8 E 12 Metal Low-E Single 9 E 13 Metal Low-E Single 10 S 14 Metal Low-E Single 11 E 15 Metal Low-E Single _ 12 W 17 Metal Low-E Single 13 E 18 Metal Low-E Single 14 S 19 Metal Low-E Single _ 15 W 20 Metal Low-E Single 16 S 23 Metal Low-E Single 17 W 24 Metal Low-E Single # Floor Area 1 832 ft2 Ceiling A 832 ft2 NFRC U-Factor SHGC Yes rea_ 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 GARAGE Exposed Wall Perimeter 17 ft INFILTRATION Overhang :np Area Depth Separatic Y 16.0 ft2 2 ft 0 in 1 ft 4 in Y 8.0 ft2 2 ft 0 in 1 ft 4 in Y 21.0ft2 2ft0in 1ft4in Y 16.0 ft2 2 ft 0 in 1 ft 4 in Y 12.0 ft2 2 ft 0 in 1 ft 4 in Y 8.0 ft2 2 ft 0 in 1 ft 4 in Y 15.0 ft2 2 ft 0 in 1 ft 4 in Y 4.0 ft2 2 ft 0 in 1 ft 4 in Y 15.0 ft2 2 ft 0 in 1 ft 4 in Y 8.0 ft2 2 ft 0 in 1 ft 4 in Y 14.0 ft2 2 ft 0 in 1 ft 4 in Y 17.5ft2 14ft0in 1ft4in Y 8.0 ft2 2 ft 0 in 1 ft 4 in Y 24.0 ft2 2 ft 0 in 1 ft 4 in Y 42.0 ft2 14 ft 0 in 1 ft 4 in Y 16.0 ft2 2 ft 0 in 1 ft 4 in Y 16.0 ft2 2 ft 0 in 1 ft 4 in Wall 9 ft Int Shade None None None None None None None None None None None None None None None None None Wall Insulation 11 # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000304 1752.1 96.13 180.47 .0969 5 None None None None None None None None None None None None None None None None None 8/16/2021 10:53 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 41 kBtu/hr 1230 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Garage 0.8 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply-- - --- Return --- Air CFM 25 CFM25 HVAC # v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 18 ft2 Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb Mar HeatinJan Feb MarAPr A r Ma Jun [X Jul Ma� Jun [ Jul Au�Xj rj Au Se SeP Oct Nov Oct Nov HX Dec Dec H Ventin Jan Feb X Mar A r [ Ma [ Jun [ Jul l l Aug Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (W EH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 - M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 MUD RM Default(8lbs/sq.ft. ft2 ft 0.3 AHU CLST 8/16/2021 10:53 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST3 Default(8 Ibs/sq.ft. f? ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING RM Default(8 Ibs/s .ft. f? ft 0.3 DINING RM 8/16/2021 10:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 97 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Windows- Description a. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: NIA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 6113 BALSAM DRIVE, FORT PIERCE, FL, New (From Plans) Detached 1 3 No 2198 Area 260.50 ftz ftz ftz ftz 4.741 ft. 0.250 Area ftz 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2198.00 ftz b. N/A R= ftz c. NIA R= ftz 10. Wall Type and Insulation a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Adjacent c. N/A d. NIA 11. Ceiling Type and insulation level a. Roof Deck (Unvented) b. N/A c. N/A 12. Ducts, location & insulation level a. Sup: Attic, Ret: Attic, AH: AHU CLST 13. Cooling systems a. Central Unit 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Natural Gas b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Q ^ /L Date: /7���L/ ` 8 ^ 2Q z-f Address of New Home: ��3��� �- City/FL Zip: �. F /, eec� ,3 �(� 8 Insulation Area R=4.1 2102.00 ftz R=11.0 158.67 ftz R= ftz R= ftz Insulation Area R=20.0 2198.00 ftz R= ftz R= ftz R ftz 6 175 kBtu/hr Efficiency 41.0 SEER:16.00 kBtu/hr Efficiency 27.0 COP:1.00 Cap: 1 gallons EF: 0.8 None �yoI-T1AE srAT�o�� DDWE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/16/2021 10:54 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: BILLIS RESIDENCE Builder Name: Street: 6113 BALSAM DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner: Jurisdiction: ST LUCIE COUNTY W Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind plOna and wiring. Showerltub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 8/16/2021 10:54 AM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1