Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
ro ect Summary Job: -�- wrightsoft PS � � By: Aug 16, 2oz1 Entire House y QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOLCOM 'Project I• • For. BILLIS RESIDENCE 6113 BALSAM DRIVE, FORT PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 27493 Btuh Structure 21140 Btuh Ducts 6983 Btuh Ducts 9848 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 34476 Btuh Use manufacturer's data n Rate/swing multiplier Equipment load 0.95 29438 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4342 Btuh Ducts 2721 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ftz) 2198 2198 Equipment latent load 7063 Btuh Volume (ft3) 21025 21025 Air changes/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 36502 Btuh Equiv. AVF (cfm) 112 56 Req. total capacity at 0. 70 S H R 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make American Standard Trade Trade AMERICAN STANDARD Model Cond 4A7A6042J1 AHRI ref Coil TEM4AOC42S41++TDR AHRI ref 8703698 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 9.4 kW Sensible cooling 28700 Btuh Heating output 32096 Btuh Latent cooling 12300 Btuh Temperature rise 21 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.040 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Pk- wrlght>softw 2021•Aug-16 10:48:03 r^^� <w�.�•i�.w. •°••�-� Right•Sulte® Universal 2021 21.0.02 RSU08101 Page 1 -4-. K E:1DocumnetslWrightsoft NVAMBILLS RESIDENCE.rup Cato = MJ8 Front Door faces: E -�+ wrrightsoft° Right-J® Worksheet Job: EntireHouse Date: Aug 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Fax 772A66-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House M BATH 2 3 Exposed wall Room height 219.0 ft 9.6 ft 27.0 ft 9.3 ft heat/cool 4 Room dimensions 1.0 x 179.0 ft 5 Room area 2198.0 ft2 179.0 ft2 Ty Construction number U-value (13tuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A4acs 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 13A-0ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, cir low-e 11DO 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazinq, cir low-e 16X19-0md 22 Aph 0.143 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.390 0.143 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.408 1.358 n n n n a a a a a _ e s s s s s w w w w _ - _ 4.00 18.20 18.20 18.20 4.00 18.20 18.20 18.20 18.20 10.92 4.00 18.20 18.20 18.20 18.20 4.00 18.20 18.20 18.20 1.59 38.02 2.19 14.99 14.99 14.99 2.19 30.39 32.08 32.42 32.81 10.34 2.19 16.03 14.99 14.99 14.99 2.19 31.84 32.08 32.81 1.37 0.00 502 8 12 16 443 4 8 30 14 21 530 8 16 24 21 619 18 40 42 _ 2198 2198 " 466 0 0 0 366 1 1 2 1 21 461 0 16 24 21 520 2 4 2. 2198 219 1867 146 218 . 291 1466 73 146 546 255 229 1847 146 291 437 . 382 2081 318 728 764 3485 8327 1020 120 180 . 240 801 122 257 973 459 217 1009 128 240 360 315 1137 557 1283 _ 1378 3007 0 149 0 0 16 0 0 0 0 0 0 0 0 0 0 0 102 0 8 0 179 179 133 0 0 0 0 0 0 0 0 0 0 0 0 '0 0 94 0 1 0 179 27 532 0 0 291 0 0 0 0 0 0 0 0 0 0 0, 378 0 146 0 284 1027 291 0 0 240 0 0 0 0 0 0 0 0 0 0 0 206 0 257 0 245 0 V C F 6 c)AED excursion 463 35 Envelope loss/gain 24043 14266 2657 1274 12 a) Infiltration 3451 924 414 111 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 5950 0 Subtotal (lines 6 to 13) 27493 21140 3070 1384 Less extemal load 0 0 0 0 14 15 Less transfer Redistribution Subtotal Duct loads 25% 470 0 0 27493 6983 0 0 21140 9848 25% 47% 0 0 3070 780 0 0 1384 645 Total room load Air required (cfm) 34476 1367 30988 1367 3850 153 2029 90 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed., ii.F- wrlghtsoft- 2021-Aug-16 10:48:03 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 1 i4C�A E:\Documnets\Wrightsoft HVAC\BILLS RESIDENCE.rup Celc = MJ8 Front Door faces: E -�- wrightsoft Right-M) Worksheet Job: Entire House Date: Aug 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOLCOM 1 2 3 4 5 Room name E)q)osed wall Room height Room dimensions Room area MASTER BEDROOM 28.0 ft 10.3 ft heat/cool 1.0 x 280.0 ft 280.0 ft2 M W Ic 10.0 ft 9.3 ft heat/cool 1.0 x 131.0 ft 131.0 ft2 Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat I Cool 6 11 13A4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 13A4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 11DO 13A4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 13A4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 16X19-0md 22A-tph 0.143 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.390 0.143 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.408 1.358 n n n n a a a a a a s s s s s w w w w - - 4.00 18.20' 18.20 18.20 4.00 18.20 18.20 18.20 18.20 10.92 4.00 18.20 18.20 18.20 18.20 4.00 18.20 18.20 18.20 1.59 38.02 2.19 14.99 14.99 14.99 2.19 30.39 32.08 32.42 32.81 10.34 2.19 16.03 14.99 14.99 14.99 2.19 31.84 32.08 32.81 1.37 '0.00 6 0 0 0 0 0 0 0 0 0 124 0 0 0 21 165 0 16 0 280 280 1 0 0 0 0 0 0 0 0 0 0 109 0 0 0 21 149 0 1 0 280 28 0 0 0 0 0 0 0 0 0 0 411 0 0 0 382 596 0 291 0 444 1065 0 0 0 0 0 0 0 0 0 0 224 0 0 0 315 326 0 513 0 383 0 93 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 131 131 93 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 131 10 372 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 208 380 263 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 179 0 V�I I--G C F 6 c)AED excursion 107 -15 Envelope loss/gain 3189 1868 960 36B 12 a) Infiltration 475 127 153 41 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 400 0 Subtotal (lines 6 to 13) 1 3664 2395 11141 409 14 15 Less e)demal load Less transfer Redistribution Subtotal Duct loads 25% 47% 0 0 15 3679 934 0 0 12 2408 1122 25% 47% 0 0 41 1155 293 0 0 34 443 206 Total room load Air required (cfm) 4613 183 3530 1561 1448 57 649 29 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -P}F- wrlghtgoft- 2021-Aug-16 10:48:03 & Right-Sulte® Universal 2021 21.0.02 RSU08101 Page 2 E:%Documnets\Wrightsoft WAC%BILLS RESIDENCE.rup Celc = MJ8 Front Door faces: E -f - wrightsoft Right-M Worksheet Job: Entire House Date: Aug 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 7724166-6796 Email: OUICKCALCS a(7 OLCOM 1 Room name PANTRY HALLWAY 2 3 Eposed wall Room height O ft 9.3 ft heaUcool O ft 9.3 ft heat/cool 4 5 Room dimensions Room area 7.0 x 9.0 ft 63.0 ft2 1.0 x 144.0 ft 144.0 ft2 Ty / Construction number U-value (Btuh/ft22F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1/IJ 2 glazing, cir lower 2 glazing, 2 glazing, clr low-e 0.143 0.650 0.650 n n n 4.20 18.20, 18.20 2.19 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D 0 0 0 0 11 2 glazing, clr low-e 13A-4ocs 2 glazing, cir low a 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 11DO 13A4ocs 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing; cir low-e 2 glazing, cir low-e 13A4acs 2 glazing, dr low-e 2 glazing, cir low-e 2 glazinq, dr low-e 16X19-0md 0.650. 0.143 0.650 0.650 0.650 0.650 0.390 0.143 0.650 0.650 0.650 0.650 0.143 0.650 650 0.650 0.650 0.408 n. a a a a a a s s s s s w w w w - 18.20 4.00 18.20 18.20 18.20 18.20 10.92 4.00 18.20 18.20 18.20 18.20 4. 18.2020 18.20 18.20 1.59 14.99 2.19 30.39 32.08 32.42 32.81 10.34 2.19 16.03 14.99 14.99 14.99 2.84 31.84 32.08 3281 1.37 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 63 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 63 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 86 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 144 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 144 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 22B 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 197 vt/ 4L�---EGG C F 22A-tph 1.358 _ - 38.02 0.00 63 0 0 0 144 0 0 0 6 c)AED excursion -14 -7 Envelope loss/gain 100 72 228 190 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 300 0 Subtotal (lines 6 to 13) 100 372 228 190 Less external load 0 0 0 0 14 15 Less transfer Redistribution Subtotal Ductloads 25% 47% 0 52 152 39 0 44 416 194 25% 47% 0 -228 0 0 0 -190 0 0 Total room load Air required (cfm) 1 191 1 8 610 27 0 1 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrlo"Tt Sc _Yt- 2021-Aug-16 10:48:03 Right-SulteO Universal 2021 21.0.02 RSU08101 Page 3 A E:\Documnets\Wrightsoft HVAC\BILLS RESIDENCE.rup Cale = MJ8 Front Door faces: E - +- wrightsoft Right-M Worksheet Job: Entire House Date- Aug 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS @[7 OL.COM 1 Room name LAUNDRY MUD RM 2 3 Exposed wall Room height 9.0 ft 9.3 ft heaticool 7.0 ft 9.3 ft heat/cool 4 5 Room dimensions Room area 1.0 x 84.0 ft 84.0 ft' 1.0 x 64.0 ft 64.0 ft2 Ty Construction number U-value (Btuh/ftz-°F) Or HTM (Btuh/ftz) Area (ftz) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat I Cool 6 11 VI! ILA--GG 13A4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 13A,4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 11DO 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 13A4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazinq, cir low-e 16X19-0md 22A-tph 0.143 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.390 0.143 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 OA08 1.358 in n n n a a a a a a s s s s s w w w _ w _ - - 4.00 18.20 18.20 18.20 4.00 18.20 18.20 18.20 18.20 10.92 4.00 18.20 18.20 18.20 18.20 4.00 18.20 18.20 18.20 1.59 38.02 2.19 14.99 14.99 14.99 2.19 30.39 32.08 32.42 32.81 10.34 2.19 16.03 14.99 14.99 14.99 2.19 31.84 32.08 32.81 1.37 0.00 84 0 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 84 84 72 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 84 9 287 0 218 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 133 342 157 0 180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 115 0 65 _ 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 64 64 57 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ 64 7 229 146 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 101 266 125. 120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 88 0 I- -G II-GG C F 6 c)AED excursion -25 -20 Envelope loss/gain 981 427 742 312 12 a) Infiltration 138 37 107 29 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 200 200 Subtotal (lines 6 to 13) 1119 664 849 541 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 36 1154 0 30 694 0 28 877 0 23 565 15 Duct loads 25% 47% 293 323 25% 47%o 223 263 Total room load Air required (cfm) 1 1448 1 57 1017 45 1100 441 828 37 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -PFi- wrightsoft- 2021-Aug-1610:48:03 " Right -Suite® Universal 2021 21.0.02 RSU08101 Page 4 E:\Documnets\Wrightsoft WAC\BILLS RESIDENCE.rup Cale = MJ8 Front Door faces: E -�- wrightsoft Right-J@ Worksheet Job: Enure House Date: Aug 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name AHU CLST CLST 2 2 3 Exposed wall Room height 0 ft 9.3 ft heat/cool 0 ft 9.3 ft heat/cool 4 5 Room dimensions Room area 4.0 x 3.0 ft 12.0 ft2 2.0 x 5.0 ft 10.0 ft2 Ty Construction number U--value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 11 2glazing, dr low-e 2 glazing, cir low-e 2 glazing, cir low-e 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 11 DO 13A4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 13A4ocs 2 glazing, dr low-e 2 glazing, dr low-e 2 olazinq, cir low-e 16X19Ond 22A4ph 0.143 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.390 0.143 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.408 1.358 n n n n a a a a a a s s s s s w w w w _ - - 4.00 18.20 18.20 18.20 4.00 18.20 18.20 18.20 18.20 10.92 4.00 18.20 18.20 18.20 18.20 4.00 18.20 18.20 18.20 1.59 38.02 2.19 14.99 14.99 14.99 2.19 30.39 32.08 32.42 32.81 10.34 2.19 16.03 14.99 14.99 14.99 2.19 31.84 3208 3281 1.37 0.00 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 12 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 19 0 000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 14 0 N13A-4ocs G ;LAG C F 6 c)AED excursion -1 0 Envelope loss/gain 19 16 16 13 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1 0 Subtotal (lines 6 to 13) 19 16 16 13 Less external load 0 0 0 0 14 15 Less transfer Redistribution Subtotal Duct loads 25% 471/6 0 -19 0 0 0 -16 0 0 25% 47% 0 -16 0 0 0 -13 0 0 Total room load Air required (cfm) 0 0 0 0 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -rF'Id- wrig_hts_oft^ 2021-Aug-16 10:48:03 Right-Sulte® Universal 2021 21.0.02 RSU08101 Page 5 C.4�A E;\DocumnetslWrightsoft WACIBILLS RESIDENCE.rup Cale = MJ8 Front Door faces: E -,' wrightsoft• Right-M Worksheet Joe: Entire House Date: Aug 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 BATH 2 2 3 E)qosed wall Room height 10.0 ft 9.3 ft heat/cool 5.0 ft 9.3 ft heat/cool 4 5 Room dimensions Room area 1.0 x 160.0 ft 160.0 ft' 14.0 x 5.0 it 70.0 ft2 Ty Construction number U-value (Btuh/ftz °F) Or HTM (Btuh/ft') Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A4ocs 2glazing, clrlow-e 2 glazing, cir low-e 2 glazing, cir low-e 13AAocs 2 glazing, or low-e 2 glazing, clr low-e 2 glazing, or low-e 2 glazing, cir low-e 11DO 13A-4ocs 2 glazing, cIr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 13A40cs 2 glazing, clrlow-e 2 glazing, clr low-e 2 glazing, cir low -a 16X19-Omd 22Adph 0. 0.650650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.390 0.143 0.650 0.650 0.650 0.650 0.13 0.6550 0.650 0.650 0.408 1.358 n n n n 'e a a a a a s s s s s w w w w _ - - 4.0 18.220. 18.20 18.20 4.00 18.20 18.20 18.20 18.20 10.92 4.00 18.20 18.20 18.20 18.20 4. 18.2020 18.20 18.20 1.59 38.02 2.19 14.99 14.99 14.99 2.19 30.39 32.08 32.42 32.81 10.34 2.19 16.03 14.99 14.99 14.99 2. 31.8484 32.08 3281 1.37 0.00 0 0 0 0 93 0 0 15 0 0 0 0 0 0 0 0 0 0 _ 0 160 160 0 0 0 0 78 0 0 1 0 0 0 0 0 0 0 0 0 0 0 160 10 0 0 0 0 312 0 0 273 0 0 0 0 0 0 0 0 0 0 0 254 380 0 0 0 0 171 0 0 486 0 0 0 0 0 0 0 0 0 0 0 219 0 0 0 0 0 47 4 0 0 0 0 0 0 0 0 0 0 0 0 0 70 70 0 0 0 0 43 1 0 0 0 0 0 0 0 0 0 0 0 0 0 70 5 0 0 0 0 170 73 0 0 0 0 0 0 0 0 0 0 0 0 0 111 190 0 0 0 0 93 122 0 0 0 0 0 0 0 0 0 0 0 0 0 96 0 ILA-G E C V�! C F 6 c)AED excursion 49 -26 Envelope loss/gain 1219 826 544 284 12 a) Infiltration 153 41 77 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 700 400 Subtotal (lines 6 to 13) 1372 1568 621 705 Less extemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 89 1461 0 74 1842 0 14 635 0 12 717 15 Duct loads 25% 47% 371 765 25% 47% 161 334 Total room load 1833 2406 796 1051 Air required (cfm) 1 1 73 106 32 46 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wrlghtsoft- 2021-Aug-1610:48:03 RlghtSuite® Universal 2021 21.0.02 RSU08101 Page 6 A E:\Documnets\WrightsoftWACXBILLSRESIDENCE.rup Calc = MJ8 Front Door faces: E -+- wrightsoft Right-JO Worksheet Job: Entire House Date. Aug 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name HALL CLST3 2 Exposed wall O ft O ft 3 Room height 9.3 ft heat/cool 9.3 ft heaticool 4 5 Room dimensions Room area 3.0 x 4.0 ft 12.0 ft' 7.0 x 2.0 ft 14.0 ft' Ty Construction number U-value (Btuh/ft2°F) Or HTM (Btuh/ft') Area (ft') or perimeter (ft) Load (Btuh) Area (W) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 Vh13A4ocs 2 glazing, cir low-e 2 glazing, dr low-e 2 glazing, cir low-e 13AAocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 11DO 13A-4ocs 2 glazing, cir low-e 2 glazing, dr low-e 2 glazing, clr low-e 2 glazing, dr low-e 13A4ocs 2 glazing, cir low-e 2 glazing, dr low-e 2 glazing, clr low-e 16X19Qmd 22A-tph 0.143 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.390 0.143 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.408 1.358 n n n n a a a a a a s s s s s w w w w _ - - 4.00 18.20 18.20 18.20 4.00 18.20 18.20 18.20 18.20 10.92 4.00 18.20 18.20 18.20 18.20 4.00 18.20 18.20 18.20 _ 1.59 38.02 2.19 14.99 14.99 14.99 2.19 30.39 32.08 32.42 32.81 10.34 2.19 16.03 14.99 14.99 14.99 2.19 31-84 32.08 32.81 1.37 0.00 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ 19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 14 14 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 14 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 22 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 19 0 yyJJ {--G C F 6 c)AED excursion -1 -1 Envelope loss/gain 19 16 22 18 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 19 16 22 18 Less external load 0 0 0 0 14 15 Less transfer Redistribution Subtotal Duct loads 1 25% 47% 0 -19 0 0 0 -16 0 0 25% 47% 0 -22 0 0 0 -18 0 0 Total room load Air required (cfm) 0 0 0 0 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrlghtsoft_^' 2021-Aug-1610:48:03 - - Rlght-Sulte@) Universal 2021 21.0.02 RSLI08101 Page 7 .4A E:\Documnets\Wdghtsoft HVAC\BILLS RESIDENCE.rup Cale = MJ8 Front Door faces: E -�- wrightsoft• Right-J@ Worksheet Job. Entire House Date: Aug 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 3 FOYER 2 Exposed wall 19.0 ft 18.0 ft 3 Room height 9.3 ft heat/cool 9.3 ft heat/cool 4 Room dimensions 1.0 x 182.0 ft 9.0 x 9.0 ft 5 Room area 182.0 ftz 81.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ftz °F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1h 13A4ocs 2 glazing, cir low-e 2 glazing, cir low-e 0.143 0-650 0.650 n n n 4.00 18.20 18.20 2.19 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 "0 0 0 0 0 0 0 0 0 11 2 glazing, cir low-e 1M-4ocs 0.650 0.143 n a 18.20 4.00 14.99 2.19 0 130 0 115 0 461 0 252 0 84 0 49 0 195 0 107 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 0.650 a a a 18.20 18.20 18.20 30.39 32.08 32-42 0 0 15 0 0 1 0 0 273 0 0 486 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 11100 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cIr low-e 2 glazing, clr low-e 0.650 0.390 0.143 0.650 0.650 0.650 0.650 a a s s s s s 18.20 10.92 4.00 18.20 18.20 18.20 18.20 32.81 10.34 2.19 16.03 14.99 14.99 14.99 0 0 47 8 0 0 0 0 0 39 0 0 0 0 0 0 164 146 0 0 0 0 0 84 128 0 0 0 14 21 84 0 0 0 0 1 21 84 0 0 0 0 255 229 335 0 0 0 0 459 217 183 0 0 0 0 13AAccs 2 glazing, cir low-e 2 glazing, cir low-e 0.143 0.650 0.650 w w w 4.00 18.20 18.20 2.19 31.84 32.08 0 0 0 0 0 0 0 0 D 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -G IL�C 2 dazing, cir low-e 16X19-0md 0.650 0.408 w - 18.20 1.59 32-81 1.37 0 182 0 182 0 289 0 249 0 81 0 81 0 128 0 111 C F 22Atph 1.358 - 38.02 0.00 182 19 722 0 81 18 684 0 6 c)AED excursion -60 -41 Envelope loss/gain 2045 1140 1827 1036 12 a) Infiltration 291 78 276 74 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 400 350 Subtotal (lines 6 to 13) 2336 1618 2103 1460 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 11 9 0 0 14 Subtotal 2347 1627 2103 1460'i 15 Duct loads 25% 47% 596 751 25% 471. 534 680i Total room load 1 2943 1 2385 1 2637 2140 Air required (cfm) 117 105 1 105 94 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. _ - k- wrlgF�isoft� 2021-Aug-16 10:48:03 RlghtSulte® Universal 2021 21.0.02 RSU08101 Page 8 P. E:\Documnets\Wrightsoft HVACIBILLS RESIDENCE.rup Cale = MJ8 Front Door faces: E - wrightsoft° Right-l® Worksheet Job: Entire House Date: Aug 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name IdTCHEN LIVING RM 2 3 Exposed wall Room height 15.0 ft 9.3 ft heat/cool 30.0 ft 10.3 ft heat/cool 4 5 Room dimensions Room area 16.0 x 15.0 ft 240.0 ftz 16.0 x 19.0 ft 304.0 ftz Ty Construction number U-value (Btuhff? °F) Or HTM (Btuh/ftz) Area (ft') or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat I Cool 6 11 2 glazing, dr lower 2 glazin , 2 glazing, cir low-e 2 glazing, cir low-e 13AAocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, dr low-e 11DO 13AAocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, dr low-e 2 glazing, cir low-e 13AAocs 2 glazing, dr low-e 2 glazing, dr low-e 2 olazirtm cir low-e 16X19-0md 22A-tph 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.650 0.390 0,143 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.408 1.358 n n n n a a a a a a s s s s s w w w w - - 4.20 18.20 18.20 18.20 4.00 18.20 18.20 18.20 18.20 10.92 4.00 18.20 18.20 18.20 18.20 4.00 18.20 18.20 18.20 1.59 38.02 4.19 14.99 14.99 14M 2.19 30.39 32.08 32.42 32.81 10.34 2.19 16.03 14.99 14.99 14.99 2.19 31.84 MOB 32.81 1.37 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 140 18 0 0 240 240 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 122 2 0 0 240 15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 488 318 0 0 381 570 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 267 557 0 0 328 0 0 0 0 0 62 0 8 0 0 0 165 0 0 24 0 82 0 0 42 304 304 0 0 0 0 54 0 1 0 0 0 141 0 0 24 0 40 0 0 2 304 30 0 0 0 0 215 0 146 0 0 0 564 0 0 437 0 162 0 0 764 482 1141 0 0 0 0 118 0 257 0 0 0 308 0 0 360 0 88 0 0 1378 416 0 I;L�GG -G it -GG C F 6 c)AED excursion 1 176 281 Envelope loss/gain 1758 1328 3910 3206 12 a) Infiltration 230 62 509 136 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1200 1500 Subtotal (lines 6 to 13) 1988 2590 4419 4842 Less extemal load 0 0 0 0 14 15 Less transfer Redistribution Subtotal Duct loads 25% 47% 0 17 2005 509 0 15 2604 1213 25% 47% 0 0 4419 1122 0 0 4842 2255 Total room load Air required (cfm) 2514 100 3617 168 5542 220 7097 313 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. "P'" wrightso_ft- 2021-Aug-1610:48:03 �' Right-Sulte® Universal 2021 21.0.02 RSU08101 Page 9 CAA E:IDocumnsts\Wrightsoft HVACIBILLS RESIDENCE.rup Calc = MJ8 Front Door faces: E - wrightsoft Right-J@ Worksheet Job. Entire House Date: Aug 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name DINING RM 2 3 Exposed wall Room height 41.0 ft 9.3 ft heat/cool 4 Room dimensions 12.0 x 14.0 ft 5 Room area 168.0 ft' Ty Construction number 1-1-value (Btuh/ftz T) Or HTM (Btuwft2) Area (ftz) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 2glazing, cir low-e 2 glazing, cir low-e 0.143 0.650 0.650 n n n 4.00 18.20 18.20 2.19 14.99 14.99 112 0 0 112 0 0 447 0 0 244 0 0 11 2 glazi-ng, clr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, cir low-e 11100 13A4ocs 2 glazing, clr low-e 2 glazing, dr low-e 2 glazing, dr low-e 2 glazing, cir low-e 13A4ocs 2 glazing, dr low-e 2 glazing, dr low-e 2 Alazinq, clr low-e _ 22A4ph 0.650 0.143 0.650 0.650 0.650 0.650 0.390 0.143 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 0.408 1.358 n a a a a a a s s s s s w w w w - 18.20 4.00 18.20 18.20 18.20 18.20 10.92 4.00 18.20 18.20 18.20 18.20 4.00 18.20 18.20 18.20 1.55 38.02 14.99 2.19 30.39 32.08 32-42 3281 10.34 2.19 16.03 14.99 14.99 14.99'. 2.19 31.84 3208 3281 1.37 0.00 0 28 0 0 0 0 0 112 0 16 0 0 130 0 16 0 168 168 0 28 0 0 0 0 0 96 0 16 0 0, 114 0 1 0 168 41 0 112 0 0 0 0 0 383 0 291 0 0 457 0 291 0 266 1559 0 61 0 0 0 0 0 209 0 240 0 0 250 0 513 0 230 0 Cr16X19-0md F 6 c)AED excursion 123 Envelope loss/gain 3806 1870 12 a) Infiltration 628 168 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 300 Subtotal (lines 6 to 13) 4434 2338 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 4434 2338 15 Duct loads 25% 47% 1126 1089 Total room load 5561 3428 Air required (cfm) 220 151 Calculations approved byACCA to meet all requirements of Manual J Sth Ed. -pk- 2021-Aug-1610:41b """"" Rlght-Suite© Universal 2021 21.0.02 RSU08101 Page 10 E:1DocumnetsMightsoft HUACIBILLS RESIDENCE.rup Cale = MJ8 Front Door faces: E -�- wrightsoft° Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax T72-466-6796 Email: QUICKCALCS@AOLCOM Froject intormation For. BILLIS RESIDENCE 6113 BALSAM DRIVE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0,500 / 0.500 in H2O 1.000 in/100ft 1367 cfm Job: Date: Aug 16, 2021 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1367 cfm 190 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 c 1051 32 46 1.000 6.0 Ox 0 VIFx 22.6 115.0 st1 BEDROOM 2 c 2406 73 106 1.000 7.0 Ox 0 VIFx 21.2 115.0 st1 BEDROOM 3 h 2943 117 105 1.000 7.0 Ox 0 VIFx 42.1 135.0 st3 DININGRM h 5561 220 151 1.000 8.0 Ox0 VIFx 55.5 135.0 st3 FOYER h 2637 105 94 1.000 7.0 Ox 0 VIFx 43.5 135.0 st3 KITCHEN c 3817 100 168 1.000 8.0 Ox0 VIFx 25.6 115.0 st1 LAUNDRY h 1448 57 45 1.000 6.0 Ox0 VIFx 4.0 95.0 LIVINGRM c 3549 110 157 1.000 8.0 Ox0 VIFx 42.6 135.0. st3 LIVING RM-A c 3549 110 157 1.000 8.0 OxO VIFx 44.3 135.0 st3 M BATH h 3850 153 90 1.000 7.0 Ox0 VIFx 23.6 115.0 st2 M WIG h 1448 57 29 1.000 5.0 Ox0 VIFx 21.4 115.0 st2 MASTER BEDROOM h 4613 183 156 1.000 8.0 Ox0 VIFx 23.6 115.0 st2 MUD RM h 1100 44 37 1.000 5.0 Ox0 VIFx 4.0 95.0 PANTRY c 6101 8 27 1 1.000 5.0 Ox 0 VIFx 23.2 115.0 1 st1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 661 664 1.000 621 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 873 1012 1.000 725 16.0 0 x 0 VinlFlx st2 Peak AVF 393 274 1.000 890 9.0 0 x 0 VinlFlx wrightsoftw 2021-Aug-16 10:48:09 �� <µ�• Rlght-Sulte® Universal 2021 21.0.02 RSU08101 Page 1 �A E:1DocumnetslWrightsoft HVAC\BILLS RESIDENCE.rup Calc = MJ8 Front Door faces: E Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1367 1367 0 0 0 0 Ox 0 VIFx wrightsoft" 2021-Aug-16 10:48:09 'R- �M<<� +-�-- mow- •-. Right Suite® Universal 2021 21.0.02 RSU08107 Peg: 2 E:1DocumnetslWrightsok WACIBILLS RESIDENCE.rup Calc = MJ8 Front Door faces: E