FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: GEMINI IMPACT BuilderName: WYNNE BUILDING CORP.
Street: Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE,FL, PermitNumber:
Owner: Jurisdiction:
Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 10. Wall Types(1763.8 sqft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1507.80 ft2
g y p y b.Frame-Wood,Adjacent R=11.0 256.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 2 d.N/A R= ft2
11.Ceiling Types (1839.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.UnderAttic(Vented) R=30.0 1839.00 ft2
6.Conditioned floor area above grade(ft2) 1839 b.N/A R= ft2
2
Conditioned floor area below grade(ft2) 0 c.N/A R=
ft
12
7. Windows(155.3 sqft.) Description Area .Ducts R ft2
a.Sup:Attic,Ret:Attic,AH:Attic 6 125
a. U-Factor: Sgl,U=1.02 115.28 ft2
SHGC: SHGC=0.27
b. U-Factor: Sgl,U=1.11 40.00 ft2 13.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.27 a.Central Unit 34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC: 14.Heating systems kBtu/hr Efficiency
Area Weighted Average Overhang Depth: 3.318 ft. a.Electric Heat Pump 34.8 HSPF:8.50
Area Weighted Average SHGC: 0.270
8. Skylights Area
c. U-Factor:(AVG) N/A ft2 15.Hot water systems
SHGC(AVG): N/A a.Electric Cap:40 gallons
9. Floor Types (1839.0 sqft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1839.00ft2 b.Conservation features
b.N/A R= ft' None
c.N/A R= ft2 16.Credits None
Glass/Floor Area: 0.084 Total Proposed Modified Loads: 51.52 PASS
Total Baseline Loads: 52.96
I hereby certify that the plans and specifications covered by Review of the plans and p1. ETAp$
this calculation are in compliance with the Florida Energy specifications covered by this y� I Z
Code calculation indicates compliance � �,�, � _Too
with the Florida Energy Code.
PREPARED BY:
Before construction is completed n�.
DATE: 1-1 -2021 this building will be inspected for
compliance with Section 553.908 ,r
I hereby certify that this building, as designed, is in compliance Florida Statutes. ,
With the Florida Energy Code.
OWNER/A T:
„ ' = BUILDING OFFICIAL:
DATE: \ DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2).
1/13/2021 7:44 AM 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: GEMINI IMPACT Bedrooms: 2 Address Type: Street Address
Building Type: User ConditionedArea: 1839 Lot#
OwnerName: Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
BuilderName: WYNNE BUILDING CORP. RotateAngle: 270 Street:
Permit Office: ST.LUCIE COUNTY CrossVentilation: No County: St.Lucie
Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE,
FamilyType: Detached FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design DailyTemp
DesignLocation TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 1839 14712
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes
2 WIC 63 504 No 0 1 No Yes Yes
3 M.BATH 56 448 No 0 1 Yes Yes Yes
4 KITCHEN 172 1376 Yes 0 1 No Yes Yes
5 MASTER BEDROO 256 2048 No 0 1 1 Yes Yes Yes
6 ENTRY 83 664 No 0 1 Yes Yes Yes
7 LAUNDRY 42 336 No 0 1 Yes Yes Yes
8 GREAT/DINING 568 4544 No 0 1 Yes Yes Yes
9 CLOSET 2 56 448 No 0 1 No Yes Yes
10 BATH 2 48 384 No 0 1 Yes Yes Yes
11 POWDER 42 336 No 0 1 No Yes Yes
12 SITTING ROOM 110 880 No 0 1 Yes Yes Yes
FLOORS
# FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet
1Slab-On-Grade Edge Insulation BEDROOM 43ft 0 343 ft2 ---- 0 1 0
2Slab-On-Grade Edge Insulation WIC 1 ft 0 63ft2 ---- 0 1 0
3 Slab-On-Grade Edge Insulation M.BATH 8 ft 0 56 ft2 ---- 0 1 0
4Slab-On-Grade Edge Insulation KITCHEN 1 ft 0 172ft2 ---- 0 1 0
5Slab-On-Grade Edge Insulation MASTER BEDRO 51 ft 0 256 ft2 ---- 0 1 0
1/13/2021 7:44 AM 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet
6 Slab-On-Grade Edge Insulation ENTRY 7 ft 0 83 ft2 ---- 0 1 0
7 Slab-On-Grade Edge Insulation LAUNDRY 6 ft 0 42 ft2 .--- 0 1 0
8Slab-On-Grade Edge Insulation GREAT/DINING 39ft 0 568ft2 ---- 0 1 0
9 Slab-On-Grade Edge Insulation CLOSET 2 1 ft 0 56 ft2 _--- 0 1 0
10SIab-On-Grade Edge Insulation BATH 2 8 ft 0 48 ft2 ---- 0 1 0
11Slab-On-Grade Edge Insulation POWDER 1 ft 0 42ft2 ---- 0 1 0
12SIab-On-Grade Edge Insulation SITTING ROOM 22ft 0 110ft2 ---- 0 1 0
ROOF
/ Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Hip Metal 1938 ft2 0 ft2 Light N 0.6 No 0.7 No 0 18.43
ATTIC
v # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1839 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood
2 Under Attic(Vented) WIC 30 Blown 63ft2 0.1 Wood
3 Under Attic(Vented) M.BATH 30 Blown 56ft2 0.1 Wood
4 Under Attic(Vented) KITCHEN 30 Blown 172ft2 0.1 Wood
5 Under Attic(Vented) MASTER BEDRO 30 Blown 256 ft2 0.1 Wood
6 Under Attic(Vented) ENTRY 30 Blown 83ft2 0.1 Wood
7 Under Attic(Vented) LAUNDRY 30 Blown 42ft2 0.1 Wood
8 Under Attic(Vented) GREAT/DINING 30 Blown 568ft2 0.1 Wood
9 Under Attic(Vented) CLOSET 30 Blown 56ft2 0.1 Wood
10 Under Attic(Vented) BATH 2 30 Blown 48ft2 0.1 Wood
11 Under Attic(Vented) POWDER 30 Blown 42ft2 0.1 Wood
12 Under Attic(Vented) SITTING ROOM 30 Blown 110ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below# Ornt To Wall Type
_ 1 S=>E Exterior Concrete Block-Int Insul BEDROOM 4.1 29 0 8 0 232.0 ft2 0 0 0.4 0
2 W=>S Exterior Concrete Block-Int Insul BEDROOM 4.1 14 0 8 0 112.0ft2 0 0 0.4 0
3 S=>E Exterior Concrete Block-Int Insul M.BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0
'4 N=>W Exterior Concrete Block-Int InsuMASTER BE 4.1 24 0 8 0 192.0 ft2 0 0 0.4 0
1/13/2021 7:44 AM 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 3 of 6
FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent SArea 'rads
F To Wall Typ" pace Cav1.ity Width Height Sheathing Framing Solar Below
0
_ Et In Et In R-41phle Erection Absor G
5 E=>N Exterior Concrete Block-Int InsuMASTER BE 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0
6 S=>E Exterior Concrete Block-Int InsuMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0
7 E=>N Exterior Concrete Block-Int insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0
8 S=>E Exterior Concrete Block-Int Insul ENTRY 4.1 1 0 8 0 8.0 ftZ 0 0 0.4 0
_9 S=>E Exterior Concrete Block-Int Insul LAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0
_10 N=>W Exterior Concrete Block-Int lnsuIGREAT/DINI 4.1 30 0 8 11 267.5 ft2 0 0 0.4 0
_11 W=>S Exterior Concrete Block-Int InsulGREAT/DINI 4.1 9 0 8 11 80.3 ft2 0 0 0.4 0
_12 N=>W Exterior Concrete Block-Int Insul BATH 2 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0
_13 N=>W Exterior Concrete Block-Int lnsuSITTING RO 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0
14 S=>E Exterior Concrete Block-Int Insu6ITTiNG RO 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0
15 W=>S Exterior Concrete Block-Int InsuSiTTING RO 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0
16 N=>W Garage Frame-Wood KITCHEN 11 32 8 256.0ft2 0.23 0.4 0
DOORS
# Ornt DoorType Space Storms U-Value Fl Width
ln FHeigh'n Area
1 E=>N Insulated ENTRY None .32 3 6 8 20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening
1 W=>S 2 Metal Low-ESingle Yes 1.02 0.27 Y 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior5
2 S=>E 3 Metal Low-ESingle Yes 1.02 0.27 Y 6.9 ft2 1 ft 0 in 1 ft 4 in None None
3 E=>N 5 Metal Low-ESingle Yes 1.02 0.27 Y 32.4 ft2 1 ft 0 in 1 ft 4 in None None
4 N=>W 10 Metal Low-ESingle Yes 1.02 0.27 Y 18.4 ft2 1 ft 0 in 1 ft 4 in None None
5 W=>S 11 Metal Low-ESingle Yes 1.11 0.27 Y 40.0 ft2 10 ft 0 in 1 ft 4 in None None
6 N=>W 12 Metal Low-ESingle Yes 1.02 0.27 Y 6.9 ft2 1 ft 0 in 1 ft 4 in None None
7 W=>S 15 Metal Low-ESingle Yes 1.02 0.27 Y 18A ft2 1 ft 0 in 1 ft 4 in None None
GARAGE
# FloorArea CeilingArea Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 320 ft2 320 ft2 32 ft 8 ft 11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50) .000254 1226 67.26 126.28 .0902 5
1/13/2021 7:44 AM 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Single SEER:15 34.8 kBtu/hr cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # CompanyName System Model# CollectorModel# Area Volume FEF
None None ft2
DUCTS
/ ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
�/ # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool
1 Attic 6 125 ft2 Attic 40 ft2 DefaultLeakage Attic (Default)c(Default)c 1 1
TEMPERATURES
ProgramableThermostat: N Ceiling Fans
CoolingJan Feb Mar Apr May Jun Jul Auge Oct Nov Dec
Heatin H
Jan H
Feb HX
Mar Apr I
i May ��Jun n Jul n Au [�j Sep Oct X)j Nov H
Dec
Ventin Jan Feb Mar [Xj Apr May Jun Jul Aug [ ]Se [X]Oct [X]Nov Dec
ThermostatSchedule: HERS 2006 Reference Hours
ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8lbs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM
Default(8lbs/sq.ft. ft2 ft 0.3 WIC
Default(8lbs/sq.ft. ft2 ft 0.3 M.BATH
Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN
Default(8lbs/sq.ft. ft2 ft 0.3 MASTER BEDROO
Default(8 Ibs/sq.ft. ft2 ft 0.3 ENTRY
Default(8lbs/sq.ft. ft2 ft 0.3 LAUNDRY
Default(8lbs/sq.ft. ft2 ft 0.3 GREAT/DINING
1/13/2021 7:44 AM 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(81bs/sq.ft. ft2 ft 0.3 CLOSET 2
Default(8lbs/sq.ft. ft2 ft 0.3 BATH 2
Default(81bs/sq.ft. ft2 ft 0.3 POWDER
Default 8lbs/s .ft. ft2 ft 0.3 SITTING ROOM
1/13/2021 7:44 AM 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 6 of 6
2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
a
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: GEMINI IMPACT Builder Name: WYNNE BUILDING CORP.
Street: Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE,FL, Permit Number: Y
U
Owner: Jurisdiction: _
Design Location: FL,Fort Pierce U
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceilinglsoffit shall be aligned with The insulation in any dropped ceiling/soffit
Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a thermal resistance of R-3
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/door jambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall .
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
cavities shall be filled by insulation that on
Narrow cavities installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac Ds.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
Pxtend behind piping and wiring
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor,wall covering or
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire
Wla in
a.In addition,inspection of log walls shall be in accordance with the provisions of ICC 400.
111312021 7:45 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index,the more efficient the home.
, FT. PIERCE, FL,
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1507.80 ft2
b.Frame-Wood,Adjacent R=11.0 256.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 2 d.N/A R= ft2
11.Ceiling Type and insulation level Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1839.00 ft2
6. Conditioned floor area(ft2) 1839 b.N/A R= ft2
c.N/A R= ft2
7. Windows- Description Area 12.Ducts,location&insulation level R ft2
a. U-Factor: Sgl,U=1.02 115.28 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 125
SHGC: SHGC=0.27
b. U-Factor: Sgl,U=1.11 40.00 ft2
SHGC: SHGC=0.27 13.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 34.8 SEERA5.00
SHGC:
d. U-Factor: N/A ft2 14.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 34.8 HSPF'.8.50
Area Weighted Average Overhang Depth: 3.318 ft.
Area Weighted Average SHGC: 0.270
8. Skylights Description Area 15.Hot water systems
a.Electric Cap:40 gallons
a. U-Factor(AVG): N/A ft2EF:0.95
SHGC(AVG): N/A b. Conservation features
9. Floor Types Insulation Area None
a.Slab-On-Grade Edge Insulation R=0.0 1839.00 ft2 Credits(Performance method) None
b.N/A R= ft2
c.N/A R= ft2
1 certify that this home has complied with the Florida Energy Efficiency Code for Building 4 , S
Construction through the above energy saving features which will be installed(or exceeded) o
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date: , `
i /FL Zi
Address of New Home: ��C\-� �;�a+►,+��� ty P �- � 'oo
5 � �Z .
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage(EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/13/2021 7:45 AM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
Project SummaryJab:
wrightsoft® Entire House Da
QUICK CALCS, INC.
317 ST.LUCIE LN.,Fr..PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@ AOL.COM
Project • •
For: THE GEMINI
WYNNE DEV.,FT.PIERCE,FL
Notes:
Design Information
Weather: Fort Pierce,FL,US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 grAb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 21011 Btuh Structure 19448 Btuh
Ducts 6289 Btuh Ducts 9502 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
none
(none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 27300 Btuh Use manufacturers data n
Rate/swingg multipplier 0.95
Infiltration Equipmentsensibleload 27502 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2170 Btuh
Ducts Ehuh
Central vent(0 cfm) 2590 Btuh
Heating cooling (none)
Area(ft2) 1839 1839 Equipment latent load 4768 Btuh
Volume(fv) 15562 15582
Air changes/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 32271 Btuh
Equiv AVF(cfm) 99 52 Req.total capacity at 0.70 SHR 3.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING
Model 25HBC536A*030 Cond 25HBC536A O30
AHRI ref 7914585 Coil FX4DN(B,F)037
AHRI ref 7914585
Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER
Heating input Sensible cooling 24360 Btuh
Heating output 34600 Btuh @47°F Latentcooling 10440 Btuh
Temperature rise 27 OF Total cooling 34800 Btuh
Actual airflow 1160 cfm Actual airflow 1160 cfm
Airflowfactor 0.042 cfm/Btuh Airflowfactor 0.040 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.86
Capacity balance point=36 OF
Backup:
Input=7 kW, Output=23009 Btuh,100 AFUE
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-F- wrightsoft® 2021-JarO307:44:09
�� ^^•°�•>�� Rigk-SuteBUriversa1201919.021 RSU08101 Page 1
UICK1Docunerts\WhgftmftHVAC1WYNNE-GEMINI.np Calc=MJ8 FrortDoorfaces:N
-9-wrightsoft Right-J®Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By,.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM
1 Room name Entire House MASTER BEDROOM
`III 212.0 It
43.0 It
3 Room height 8.5 It d 8.0 ft heat/cool
4 Room dimensions 1.0 x 343.0 it
5 Room area 1839.0 ft' 343.0 ft2
Ty Construction U-value Or HTM Area Load
W) Load number (Btuhr--°F) (Btuh/ft2) or perimeter (ft) (Btuh ors perimei)er (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 628 602 2412 1533 0 0 0 0
1A-clom 1270 n 35.56 34.77 7 0 247 241 0 0 0 0
4A5-2om 0.770 n 21.56 19.31 19 0 407 365 0 0 0 0
13A-4ocs 0.143 e 4.00 2.55 152 98 394 250 0 0 0 0
11 G 1A-clom 1270 e 35.56 8729 33 2 1162 2853 0 0 0 0
D 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0
13A-4ocs 0.143 s 4.00 2.55 473 466 1868 1187 232 232 929 591
Y-G 1A-clom 1270 s 35.56 34.77 7 7 247 241 0 0 0 0
TE� 13A4ocs 0.143 w 4.00 2.55 295 203 813 517 112 79 318 202
1A-clom 1270 w 35.56 5525 33 2 1162 1806 33 2 1162 1806
4A5-2om 0.770 w 21.56 44.72 19 2 407 845 0 0 0 0
4A5-2ovd 0.470 w 13.16 35.61 41 2 537 1453 0 0 0 0
P 12C-Osw 0.091 2.55 128 224 224 571 287 0 0 0 0
C 16A-30md 0.032 0.90 2.32 1839 1839 1648 4266 343 343 307 796
F 22A-tpl 0.989 27.69 0.00 1839 212 5871 0 343 43 1191 0
6 c)AED excursion 508
618
Envelopeloss/gain 17975 16592 3907 4012
12 a) Infiltration 3037 856 674 190
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants@ 230 0 0 0 O
Applianoes/other 2000 0
Subtotal(lines6 to 13) 21011 19448 4581 4202
Less exemal load 0 0 0 0
Less transfer 0 0
0 0
Redistribution 0 0 0 0
14 Subtotal 21011 19448 4581 4202
15 Duct loads 30% 49% 6289 9502 30% 49% 1371 2053
Total room load 27300 28950 5952 6255
Air required(cim) 1160 1160 253 251
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
2021-Jan•1307:44:09
Ac-�ffA R gh!-Sate®Uriversal 201919.021 RSU08101 Page 1
UICK\Doaxmris\WngttsoftHVAC\WYNNE-GEMINI.rtp CaIc=MJ8 FrontDoorfaces:N
-9-wrightsoft Right-J®Worksheet Date:
Entire House Date:
QUICK CALCS, INC. By.
317 ST.LUCIE LN.,Fr..PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM
1 Room name WIC M BATH
2 E)posed wall 0 It 8D ft
3 Room height 8.0 ft heat/000l 8.0 It heat/cool
4 Room dimensions 7.0 x 9.0 it 7.0 x 8.0 It
5 Room area 63.0 IF 56.0 fP
Ty Construction U-value Or HTM Area Load number (Bluhlftk-F) (BbJhll�) or perimeter s
r (ft) (BWh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A11as 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0
!A-c1om 1270 n 35.56 34.77 0 0 0 0 0 p p p
4A5 tom 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0
13A4ocs 0.143 e 4.00 2.55 0 0 0 0 0 0 0 0
11 G 1Ac1om 1270 a 35.56 8729 0 0 0 0 0 0 0 0
D 11 DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
13A4o s 0.143 s 4.00 2,55 0 0 0 0 64 57 228 145
t-G IA-c1om 1270 s 35.56 34.77 0 0 0 0 7 7 247 241
TEG
13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
O 1Ac1om 1270 w 35.56 5525 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 44.72 0 0 0 0 0 0 0 0
4A5-2ovd 0.470 w 13.16 35.61 0 0 0 0 0 0 0 0
P 12C-09w 0.091 2.55 128 0 0 0 0 0 0 0 0
C 16A-30md 0.032 0.90 2.32 63 63 56 146 56 56 50 130
F 22A tpI 0.989 27.69 0.00 63 0 0 0 56 .8 222 0
61 c)AED excursion -12 -47
Envelope loss(gain 56 134 747 469
12 a) Infiltration 0 0 125 35
b) Room ventilation 0 0 0 0
13 Internal gains: Oocupants@ 230 0 0 0 p
Appliances/other 0 0
Subtotal(lines 6 to 13) 56 134 872 505
Less exdemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 56 134 872 505
15 Duct loads 130% 49%1 17 65 30% 49% 261 247
Total room load 73 199 1133 751
Air required(dm) 3 8 48 30
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-;`�- wr�gFftsofia
.4 Right-SdW Universal 201919.021 RSU08101 2021-Jan•13 07.4 UICK1DommriMWdghtmftWAC1WYNNE-GEMINI.rup Calc=MJ8 FrontDoorfaoes:N Page 2
- wriightsoft° Right-J®Worksheet Date:
Entire House By.
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466.6796 Email:QUICKCALCS c(��AOL.COM
1 Room name KrrCHEN MASTER BEDROOM2
2 Exposed wall 8.0 ft 51 D ft
3 Room height 8.0 ft heaftol 8.0 ft heallocol
4 Room dimensions 1.0 x 172.0 ft 1.0 x 256.0 ft
5 Room area 172.0 ft2 256.0 ftz
Load
Load
Ty I
Construumber�on (BtuhAV--F) Or HTIVI(BtuhAl2) orsperimeter (ft) (Btuh) or�perim�r (ft) (fth)
Heat I Cool Gross NIPS Heat Cool Gross I NIPlS Heat I Cool
6 V+/ 13A14o s 0.143 n 4.00 2.55 0 0 0 0 192 192 769 489.
II----GG 1A-clom 1270 n 35.56 34.77 0 0 0 0 0 0 0 0
4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0
V� 13A-flocs 0.143 a 4.00 2.55 0 0 0 0 104 71 286 182
11 �--G 'IA-clam 1270 e 35.56 8729 0 0 0 0 33 2 1162 2853
L-D 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
1/I/ 13A-flocs 0.143 s 4.00 2.55 0 0 0 0 112 112 448 285
L-G 1A-clom 1270 s 35.56 34.77 0 0 0 0 0 0 0 0
JE13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
G 1A-clom 1270 w 35.56 5525 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 44.72 0 0 0 0 0 0 0 0
4A5-2ovd 0.470 w 13.16 35.61 0 0 0 0 0 0 0 0
P 12C-Osv 0.091 2.55 128 64 64 163 82 0 0 0 0
C 16A30md 0.032 0.90 2.32 172 172 154 399 256 256 229 594
F 22A tpl 0.989 27.69 0.00 172 8 222 0 256 51 1412 0
6 c)AED excursion -211 -176
Envelope loss(gain 539 270 4307 4227
12 a) Infiltration 0 0 800 226
b) Room ventilation 0 0 0 0
13 Intemalgains: Occupants@ 230 0 0 0 0
Applianoes/other 2000 11 0
Subtotal(lines 6 to 13) 539 2270 5106 4452
Less external load 0 0 0 0
Lesstransfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 539 2270 5106 4452
15 Dud loads 30% 49% 161 1109 30% 49% 1528 2175
Total room load 700 3380 6635 6627
Air required(dm) 30 135 282 266
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wr�ghtsolR^ 2021-Jan-13 07:44:09
A. & Right-Sute@Uriversal20l9l9.021 RSU08101 Page
...UICK1Doaxmrts\WrightmftHVAC\WYNNE-GEMINI.np Calc=MJ8 FrontDoorlaces:N
- wrightsoft` Right-J®Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS ,AOL.COM
1 Room name ENTRY LAUNDRY
2 F)posedwall 20.0 It 13.0 ft
3 Room height 8.0 It heat/000l 8.0 ft heaU000l
4 Room dimensions 1.0 x 83.0 It 7.0 x 6.0 ft
5 Room area 83.0 fe 42.0 fe
Ty Construction U-value Or HTM Area Load number (Btuh/fj2-°F) (Btuh/IF) or perimeter �
r (ft) (Btuh) or perimeter Load
eter (ft) (BWh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 VL13A4o s 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0
1A-c1om 1270 n 35.56 34.77 0 0 0 0 0 0 0 0
4A5-2om 0.770 n 21.56 19.31 -0 0 0 0 0 0 0 0
13A4as 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0
11 IA-c1om 1270 a 35.56 8729 0 0 0 0 0 0 0 0
D 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0
�/ 13A-4o s 0.143 s 4.00 2.55 8 8 32 20 48 48 192 122
I G 1A-c1om 1270 s 35.56 34.77 0 0 0 0 0 0 0 0
13A4os 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
1A-c1om 1270 w 35.56 5525 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 44.72 0 0 0 0 0 0 0 0
4A5-2oA 0.470 w 13.16 35.61 0 0 0 0 0 0 0 0
P 12C-0sw 0.091 2.55 128 104 104 265 133 56 56 143 72
C 16A-30md 0.032 0.90 2.32 83 83 74 193 42 42 38 97
F 22A-tpl 0.989 27.69 0.00 83 20 554 0 42 13 360 0
6 c)AED excursion -58 -27
Envelope loss(gain 1263 595 733 264
12 a) Infiltration 110 31 94 27
b) Room ventilation 0 0 0 0
13 Internal gains'. Occupants@ 230 0 0 0 0
Appliances(other 0 0
Subtotal(lines 6 to 13) 1372 625 827 291
Less e)(temalload 0 0 0 0
Lesstransfer 0 0 0 0
Redishibution 0 0 0 0
14 Subtotal 1372 625 827 291
15 Dud loads 30% 49% 411 306 30% 49% 247 142
Total room load 1783 931 1074 433
Air required(clm) 76 37 46 17
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed.
-�- wrightsolt� 2021-Jan-1307:44:09
.4 A Right-Suite@ Universal 201919.021 RSU08101 Page
UICK1Docurnerts\WdgtUoftHVADWYNNE-GEMINI.n¢) Calc=MJ8 FrontDoorfaces:N
-9-wrightsoft Right-J®Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST.LUCIE LN.,Fr..PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name GREAT/DINING CLOSET 2
3 Room he height 8.9 it wall 39.0 ft heat/oDol 9.4 ft Oft heat/000l
4 Room dimensions 1.0 x 568.0 ft 7.0 x 8.0 it
5 Room area 568.0 ft2 56.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (BtuhtF--°F) (Btirh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 VLG13AAocs 0.143 n 4.00 2.55 267 248 993 632 0 0 0 0
1A-clom 1270 n 35.56 34.77 0 0 0 0 0 0 0 0
G 4A5-2om 0.770 n 21.56 19.31 19 0 407 365 0 0 0 0
13AAocs 0.143 e 4.00 2.55 0 0 0 0 0 0 0 0
11 G 1A-clom 1270 e 35.56 8729 0 0 0 0 0 0 0 0
D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
13AAocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0
T-G 1A-clom 1270 s 35.56 34.77 0 0 0 0 0 0 0 0
13A-4ocs 0.143 w 4.00 2.55 80 39 157 100 0 0 0 0
TEG
IA-clom 1270 w 35.56 5525 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 44.72 0 0 0 0 0 0 0 0
4A5-2ovd 0.470 w 13.16 35.61 41 2 537 1453 0 0 0 0
P 12C-09w 0.091 2.55 128 0 0 0 0 0 0 0 0
C 16A-30md 0.032 0.90 2.32 568 568 509 1318 56 56 50 130
F 22A-tpl 0.989 27.69 0.00 568 39 1080 0 56 0 0 0
6 c)AED excursion 256 11
Envelope loss/gain 3684 4123 50 119
12 a) Infiltration 680 192 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants@ 230 0 0 0 0
Applianoescother 0 0
Subtotal(lines 6 to 13) 4364 4315 50 119
Less extemalload 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 4364 4315 50 119
15 Ductloads 30% 49% 1306 2108 30% 49% 15 58
Total room load 5671 6423 65 177
Air required(cfm) 241 257 3 7
Calculations approved bVACCAto meet all requirements of Manual J 8th Ed
-�- wrigF�tsofta�� tZght-Sute® 2021-Jan•1307:44:09
Uriversa1201919.021 RSU08101 Pages
..UICK\Doamerts\WnghtsoftHVAC\WYNNE-GEMINI.rLp Calc=MJ8 Front Door faces:N
-lf-wrightsoft° Right-J®Worksheet Date:
Entire House By.
QUICK CALCS, INC.
317 ST.LUCIE LN.,Fr.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS AOL.COM
1 Room name BATH 2 POWDER
2 Exposed wall 8.0 It 0 ft
3 Room height 9A It heaVcool 9.4 It heaVcool
4 Room dimensions 6.0 x 8.0 ft 7.0 x 6.0 ft
5 Room area 48.0 f€ 42.0 tt�
Ty Construction U-value Or HTM Area (fts) Load Area (ft) Load
number (BtuhhV--°F) (BtuhtP) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross NIPS Heat Cool Gross N/P/S Heat I Cool
6 yJ 13A-0ocs 0.143 n 4.00 2.55 75 68 273 174 0 0 0 0
IL-_G 1Ac1om 1270 n 35.56 34.77 7 0 247 241 0 0 0 0
G 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0
V�/ 13A-4ocs 0.143 e 4.00 2.55 0 0 0 0 0 0 0 0
11 �--G 1A-c1om 1270 e 35.56 8729 0 0 0 0 0 0 0 0
L--D 11DO 0.390 e 10.92 11.31 0 0 0 0 0 0 0 0
V�1 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0
G' 1A-c1om 1270 s 35.56 34.77 0 0 0 0 0 0 0 0
13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
JEG
G 1A-clom 1270 w 35.56 5525 0 0 0 0 0 0 0 0
4A5-2om 0,770 w 21.56 44,72 0 0 0 0 0 0 0 0
4A5-2oKi 0.470 w 13.16 35.61 0 0 0 0 0 0 0 0
P 12C-Osw 0.091 2.55 128 0 0 0 0 0 0 0 0
C 16A-30md 0.032 0.90 2.32 48 48 43 111 42 42 38 97
F 22A-tpl 0.989 27.69 0.00 48 8 222 0 42 0 0 0
6 c)AED excursion -48 -8
Envelope loss/gain 784 478 38 89
12 a) Infiltration 147 42 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants@ 230 0 0 0 0
Applianceslother 0 0
Subtotal(lines 6 to 13) 932 520 38 89
Less extemalload 0 0 0 0
Lesstransfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 932 520 38 89
15 Duct loads 30% 49%1 2791 254 30% 49% 11 44
Total room load 1211 773 49 133
Air required(dm) 51 31 2 5
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-F� wrightso?r^ 2021-Jan-1 3 07:44:09
A&A Riga-Suite®Universal 2019 19.021 RSU08101 Page
UICK1Docunerts\WrighfsoftHVAC\WYNNE-GEMINI.ryp Calc=MJ8 FrontDoorfaces:N
-F�wrightsoft° Right-J®Worksheet p :
Entire House By.
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772.466-6799 Fax.772-466-6796 Email:QUICKCALCS@,AOL.COM
1 Room name DEN
2 Exposed wall 22.0 It
3 Room height 9.4 It heaUcool
4 Room dimensions 11.0 x 10.0 ft
5 Room area 110.0 ft
Ty Construction U-value Or HTM Area (ft') Load Area Load
number (BtuhHtz-°F) (BtuW) or perimeter (ft) (Bluh) or perimeter
Heat I Cool Gross N/P/S Heat I Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 94 94 376 239
I-C 1A-c1om 1270 n 35.56 34.77 0 0 0 0
_G 4A5-2om 0.770 n 21.56 19.31 0 0 0 0
13A-4ocs 0.143 e 4.00 2.55 0 0 0 0
11 G 1A-c1om 1270 e 35.56 8729 0 0 0 0
D 11DO 0.390 a 10.92 11.31 0 0 0 0
13A-4ocs 0.143 s 4.00 2.55 9 9 38 24
I-G 1Aclom 1270 s 35.56 34.77 0 0 0 0
13A-4ocs 0.143 w 4.00 2.55 103 84 338 215
1A-clom 1270 w 35.56 5525 0 0 0 0
4A5-2om 0.770 w 21.56 44.72 19 2 407 845
T� 4A5-2ovd 0.470 w 13.16 35.61 0 0 0 0
P 12C-Ow 0.091 2.55 128 0 0 0 0
C 16A-30md 0.032 0.90 2.32 110 110 99 255
F 22A-tpI 0.989 27.69 0.00 110 22 609 0
6 c)AED excursion 233
Envelope losstgain 1868 1811
12 a) Infiltration 405 114
b) Roomventilation 0 0
13 Internal gains: Occupants @ 230 0 0
Applianceother 0
Subtotal(lines 6to 13) 2273 1926
Less extemai load 0 0
Lesstransfer 0 0
Redistribution 0 0
14 Subtotal 2273 1926
15 Dudtoads 30% 4901. 680 941
Total room load 2953 2867
Air required(dm) 125 115
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
_ wr10kvtts4nol't- 2021-Jan•1307:44:09
A&k Right-Sute®Uriversal201919.021 RSU08101 Page
UICK\Doamerts\WdghtsoftHVAC\WYNNE-GEMINI.nip Calc=MJ8 FrontDoorfaces:N
- wrightsoft® Duct System Summary o :
Entire House By.
QUICK CALCS, INC.
317 ST.LUCIE UN.,FT.PIERCE,FL 34946 Phore:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS AOL.COM
Project • •
For: THE GEMINI
WYNNE DEV.,FT.PIERCE,FL
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.50 in H2O 0.50 in H2O
Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O
Lowest friction rate 0.286 in/100ft 0.286 in/100ft
Actual airflow 1160 cfrn 1160 cfm
Total effective length(TEL) 175 it
SupplyBranch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (in) (in) Mat Ln(ft) Ln(ft) Trunk
BATH 2 h 1211 51 31 0.368 4.0 Ox 0 M Fx 21.0 115.0 st1
CLOSET2 C 177 3 7 0.363 4.0 Ox0 VIFx 22.6 115.0 st1
DEN h 2953 125 115 0.289 7.0 Ox0 VIFx 38.1 135.0 st2
ENTRY h 1783 76 37 0.485 4.0 Ox0 VIFx 8.1 95.0
GREAT/DINING-A c 3211 120 129 0.300 6.0 Ox0 VIFx 31.7 135.0 st2
GREAT/DINING-B c 3211 120 129 0.308 6.0 Ox 0 VIFx 27.3 135.0 st2
KITCHEN c 3380 30 135 0.376 7.0 Ox0 MFx 18.1 115.0 st1
LAUNDRY h 1074 46 17 0.369 6.0 Ox0 VIFx 20.4 115.0 st1
M.BATH h 1133 48 30 0.366 4.0 Ox 0 VI Fx 21.6 115.0 st1
MASTERBEDROOM h 2976 126 125 0.286 6.0 Ox0 VIFx 40.1 135.0 st2
MASTER BEDROOM 2 h 6635 282 266 0.352 7.0 Ox 0 VIFx 27.2 115.0 st1
MASTERBEDROOWA h 2976 126 125 0.297 6.0 Ox0 VIFx 33.1 135.0 st2
POWDER c 133 2 5 0.379 4.0 Ox0 VIFx 17.1 115.0 st1
wlc c 199 3 8 0.309 4.0 Ox0 VIFx 26.6 135.0 st2
SupplyDetail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st2 PeakAVF 622 631 0.286 803 12.0 0 x 0 VinIFIX st1
st1 PeakAVF 1084 1123 0.286 804 16.0 0 x 0 VinlFlx
41- wrightsoft® 2021-Jarr1307:44:09
o� Awe �w aim Rgtt-SLite@Uriversal20l9l9.021 RSU08101
ACM Page 1
..UICK1Doamerts\WrigftwftWAC\WYNNE-GEMINI.n{p Calc=MJ8 FrontDoorfaces:N
TableReturn Branch Detail
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) MM) 00 FR (fpm) (in) (in) Opening(in) Mail Trunk
rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 MFx
41- wrightsoft® 2021-Jan-1307:44:09
Mgft-Sute®Uriversal201919.021 RSU08101 Page
A+CK ...UICKVDocunerds\WrightsoftHVAC\WYNNE-GEMINI.np Calc=MJ8 Frorft Door faces:N