HomeMy WebLinkAboutPool Construction Design15, Foom 1r x 1r K 2 #5 15'OF +18" RAISED WALL TILE FINISH ALL SIDES W! 1- 36" SHEER DESCENT 53, -------------: ( M BABY FENCE MIN OF 2W FROM WATERS EDGE 6 48" HIGH • • , FBC 7^H EDITION 2020 R4501.17A • 8' I : � N I I DP 18"x12'SWIMOLIT I SEE PIPING SCHEMATIC h FOR DETAILS AND SIZES , I PAGE P-1 0 aml 0 0 0 9 GFI LOCATION MIN 6' 3 MAX OF 2a To WATERS EDGE AUTOFILL TO BE THROUGH A BACKFLOW PROTECTION DEVICE F.B.C. AS PER 7TM EDITION (2020) FBC R4501 A POOL EQUIQMENT SHALL BE SCREENED IF REWIRED BY LOCAL CODE RESIDENCE NOTE: TOP OF POOL ELEVATION IS 6" LOWER THAN F.F.E. OF HOUSE CLEANING LINE WITH VAC'LOC FITTING SHALL BE LOCATED NO GREATER THAN 12" BELOW WATER LEVEL APSP 7 SEC 4.6 NOTE: POOL CONTRACTOR TO VERIFY ALL PROPERTY LINE LOCATIONS AND POOL ELEVATION PRIOR TO CONSTRUCTION. POOL LAYOUT AND DIMENSIONS TO BE VERIFIED W/ OWNER PRIOR TO CONSTRUCTION 10F 5 DRAFTED BY: G.S.M. I SCALE: 1/8" =1' 22,0-t'o6Zs REVIEWED FOR CODE COMPLIANCE ST. LUCIEC��OUNTY BOCC --------.------------- i I 8' I I I I I • io • DANIEL DUVERTON & VERONICA 2990 JOHNSTON ROAD FT PIERCE, FL 34951 DRAIN SPECIFICATI( POOL SIZE: I 18' X 35' POOL DEPTH; 3'6" - 7' DCODIIIAC=D• 106' VOLUME: (GALLONS) 19,667 TURNOVER RATE: POOL AREA SQ. FT. 594 POOL PUMP: I DANDY FLO PRO 1.65 HP VSP I SPA SIZE: POOL FILTER: 340 SF CARTRIDGE SPA POOL S.FJL.F. /GAl POOL INLETS: 1 4 1 SPA JETS: SKIMMER: 1 1 SPA LIGHT: POOL LIGHT: 3 — LED NICHELESS RAISED SPA: POOL HEATER TYPE: N/A SPA COPING: POOL HEATER SIZE: N/A SPA EXTERIOR: CLEANING LINE: VAC SPA SPILLWAY SIZE: CLEANING SYSTEM: N/A AUTOMATED SYSTEM: CHLORINATOR: IN LINE BLOWER: BOOSTER PUMP: A N/A N/A N/A NIA NIA NIA NIA NIA NIA POOL FINISH ITEMS COPING: TRAVERTINE INTERIOR FINISH: FL GEM TILE: 6" X 6" DECK S.F.: 936 SWIMOUT: 18" X 12' DECK TYPE: TRAVERTINE CAP TILE 28' CAPPING S.F.: N/A HANDHOLDS: I N/A FOOTERS: 1111, HANDRAIL: I N/A DOD: 53' UMBRELLA SLEEVE: I NIA PILING POOL: N/A SPECIAL NOTES 6' RAISED BEAM: I NIA ACTUATORS: NIA 12" RAISED BEAM: N/A ALARMS: NIA 18" RAISED BEAM: 15' ELECTRIC: YES 24' RAISED BEAM: N/A 36" RAISED BEAM: NIA OVERFLOW LINE: POOL ENCLOSURE: I YES 360 DEGREE BABY FENCE RAISED BEAM FINISH TILE BEAM FINISH SIDES TILE GATES: NIA BEAM FINISH REAR TILE BABY FENCE: 122 LF WATER FEATURES DECK JETS: NIA SHEER DESCENT: 1-36- BUBBLERS: N/A LYONS HEADS: NIA AUTO FILL: YES WATERFAW ROCK NIA THERAPY JETS: N/A OTHER: I NIA FILE COPY�• A' NAYNE MARKHAM BENNETT PE #57216 11ARKHAM SERVICES, INC. (CA 33018) a • • ` 1820 NE JENSEN BEACH BLVD #685 IENSEN BEACH, FL 34957-7212 2/11 /2022 dj £%,' (954) 81"251 wayne@wmbpa.=n *r • . S) a 1 a!� ff,•� ..pp� IF THERE IS A DIGITAL SIGNATURE ON THE FRONTIFIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL GNATURE ON THIS SHEET I�sl!a FISIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMBJT ARE NOT CONSIDERED #3@8'OCEW _ THROUGH RAISED BEAM e' SHEER DESCENT WATER LEVEL 6-MIN8' MIN. GUNITEISHOTCRETE WALL8 6 GIORWITH#3BARS@9' O.C.E.W.CENTERED SEE TYPICAL WALL SECTION FOR DETAILS RAISED WALL SECTION IMPORTANT NOTE: NO DIVING BOARD AND NO DIVING IS ALLOWED ON ANY POOL LESS THAN n" DEEP AND SPECIFICALLY DESIGNED FOR DIVING. THIS POOL IS NOT DESIGNED FOR DIVING. 1. 35' 1. r r r r r 5 1:7 NU DaMUM SLOPE WATER LINE ;o m G'i m MAIN DRAIN LONGITUDINAL POOL SECTION N.T.S. 2 OF 5 I DRAFTED BY: G.S.M. lull 6" X 6" BEAM 2 #3 CONTINUOUS to LE • (TYP • SWIMOUT DETAIL N.T.S. DANIEL DUVERTON & VERONICA 2990 JOHNSTON ROAD FT PIERCE, FL 34951 BULLNOSEI STRAIGHT EDGE PAVER/TRAVERTINE TYP OR CONCRETE CANTILEVER CAP POURED IN PLACE. WATER LIN TILE INTERLOCKING TRAVERTINE /PAVER SET IN SAND ON COMPACTED FILL SLOB 12" X 12" CONC. FTG. W/ 2 # 5 CONT. APPROVED FIN H .� io TYPICAL WALL SECTION N.T.S. •.�6" X 6" BEAM W/2• #3 CONT. 6" MIN. GUNITEISHOTCRETE WALLS & FLOOR WITH #3 BARS @ 9" "O.C.E.W. CENTERED FOR DEPTHS TO 5' AFTER 5' #3 @ 6" OCEW STEELTEX FORM, KRAFTBOARD OR EQUIV. W TER LEVEL 12" 12" 18" COPING 8 X 8 BEAM 2 #3 CONTINUOUS 12'MAX WATER LEVEL TILE 12'MAX i 91 -07 12" MAX !i 1rMAX r NO MIN T EARTH 2- POOL STEP DETAIL `NTH STEPS TO HAVE A 10" MINIMUM TREAD AND A 12" MAXIMUM RISER FILE COP WAYNE MARKHAM BENNETT P.E. #57216 MWMAM SERVICES, INC. (CA 33018) 1820 HE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 2/7/2022 (954) 818-38251 wayne@wmbpe.00m IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET IF SIGNED DIGITALLYABOVE, PRINTED COPES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES C MIN. FROM WATER I LEVEL TO TOP OF LEN I LOW VOTLAGE N LIGHT POOL LIGHT NICHE DETAIL N.T.S. POOL LIGHT U.L. APPROVED 1 %"" PVC CONDUIT FROM 12V TRANSFORMER ELECTRICAL CONTRACTOR SHALL VERIFY THAT THE EXISTING SERVICE AND PANEL HAS ENOUGH CAPACITY TO ACCOMMODATE THE ADDED POOL EQUIPMENT LOAD PER NEC 220.82" NOTE. BASED ON INFORMATION PROVIDED TO THIS OFFICA THE EXISTING SERVICE EXISTING PANEL 2P IS ADEQUATE FOR THE PROPOSED ADDITIONAL POOL EQUIPMENT LOAD REAKER NG POOL '/.' PVC CONDUIT W/ 2 #6 HOT, 1 #10 GRND.1 #10 NEUTRAL o POOL PUMP (1) - 2 P-20A GFCI EXISTING PANEL LIGHT -CHLORINATOR (1)-lP-15A METER064 L�,J cFcls• ro za TRANSFORMER 120-12V 300 Wl TRANSF FROMWATER F.P ffi� .L (L1ID PUMP 3 #12,1 #12 GRND. GFCI PROTECTED W PVC 2#12, SALT CHLORINATOR 2 #12,1 #12 GRND. ',V PVC 1#12 GRND. 48' MIN. POOL DECK LEVEL 1) JUNCTION BOX 1. W POOL AREA GROUND ALL BOXES, RAILS, LIGHT, MOTOR ECT WITH 30 1' NON -CORROSIVE #B BARE COPPER WIRE CONDUIT 2. ALL ELECTRICLA TO COMPLY WITH 2O17 NATIONAL ELECTRICAL m CODE ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION 3. #12 THHN CU W MIN. CONDUIT FOR POOL LIGHT(S), (3)12V 24W LE D. NICHELESS LIGHTS (POOL) 4. ALL POOL PUMPS To BE GFCI PROTECTED PER NEC 680.22(B). 5. LOAD CALCULATIONS FOR EXISTING SERVICE AND PANEL -BY OTHERS 6. PROVIDE G.F.C.L OUTLET V MIN - 20' MAX FROM WATERS EDGE. ELECTRICAL RISER DIAGRAM N.T.S. DRAFTED BY: G.S.M. I AGE 3 OF 5 #8 BARE COPPER WIRE FOR 360° WITH 4 JUMPERS TO BE Is- TO 24' WATEIkLINE FROM WATERS EDGE EQUIPO ENTIAL PER FLORIDA BUILDING CODE ADAPTION OF N.E.C. 2017 SEC 680.26 POOL BOND SCHEMATIC N.T.S. DANIEL DUVERTON & VERONICA 2990 JOHNSTON ROAD FT PIERCE, FL 34951 NOTE PROVIDE CONTINOUS I ELECTRICAL CODE and NOTES: SINGLE 0 COOPER BONDED IN FOUR POINTS (366 )AROUND National Electrical Code (NEC), NFPA 70 .2017 shall specifically govem, including Article 680 POOL 6 SPAAS PER N.E.C. 2017 ART. 68026 (B)a(c) Swimming Pools, Fountains, and Similar Installations Article 430.32 Continuous -Duty Motors. Each motor used in continues duty application shall be protected against overload Article 680.6 Grounding. Electrical equipment shall be grounded in accordance with Parts V, VI and VII of Article 250 and connected by wiring methods of Chapter 3, except as modified by this Article. The following equipment shall be grounded: (1) Through -wall lighting assemblies and underwater luminaires, other than those low -voltage lighting products listed for the application without a grounding conductor (2) All electrical equipment located within 1.5 m (5 ft) of the inside wall of the specified body of water (3) All electrical equipment associated with the recirculating system of the specified body of water (4) Junction boxes (5) Transformer and power supply enclosures (6) Ground -fault circuit interrupters (7) Panelboards that are not part of the service equipment and that supply any electrical equipment associated with the body of water Article 680.9 Overhead Conductor Clearances. Overhead conductors shall meet the NOTE BOND WIRE TO BE SECURED clearance requirements in this section. Where a minimum clearance from the water level is given, TO BEEEL ENCASED IN DECK S CLAMP, the measurement shall be taken from the maximum water level of the specified body of water. A TO BE ENCASED IN DECK SLAB OR CONCRETE I� Y ( ) BOX PROVIDING MIN. Power. With respect to service -drop conductors, overhead service conductors, and open r OF COVER AROUND CLAMP overhead wiring, swimming pool and similar installations shall comply with the minimum clearances given in Table 680.9(A) and illustrated in Figure 680.9(A). (B) Communications Systems. Communications, radio, and television coaxial cables within the scope of Articles 800 to 820 shall be permitted at a height of not less than 3.0 m (10 ft) above swimming and wading pools, diving structures, and observation stands, towers, or plafforms. (C) Network -Powered Broadband Communications Systems. The minimum clearances for overhead network -powered broadband communications systems conductors from pools or fountains shall comply with the provisions in Table 680.9(A) for conductors operating at 0 to 750 volts to ground. Article 680.10 Electric Pool Water Heaters. All electric pool water heaters shall have the heating elements subdivided into loads not exceeding 48 amperes and protected at not over 60 amperes. The ampacity of the branch -circuit conductors and the rating or setting of overcurrent protective devices shall not be less than 125 percent of the total nameplate -rated load. Article 680.11 Underground Wiring Location. Underground wiring shall be permitted where installed in rigid metal conduit, intermediate metal conduit, rigid polyvinyl chloride conduit, reinforced thermosetting resin conduit, or Type MC cable, suitable for the conditions subject to that location. Underground wiring shag not be permitted under the pool unless this wiring is necessary to supply pool equipment permitted by this article. Minimum cover depths shall be as given in Table 300.5. Article 680.22 Lighting, Receptacles, and Equipment. (A) Receptacles. (1) Required Receptacle, Location. Where a permanently installed pool is installed, no fewer than one 125- volt,15- or 20-ampere receptacle on a general-purpose branch circuit shall be located not less than 1.83 In (6 ft) from, and not more than 6.0 m (20 ft) from, the inside wall of the pool. This receptacle shall be located not more than 2.0 m (6 ft 6 in.) above the floor, platform, or grade level serving the pool. (2) Circulation and Sanitation System, Location. Receptacles that provide power for water -pump motors or for other loads directly related to the circulation and sanitation system shall be located at least 1.83 m (6 ft) from the inside walls of the pool. These receptacles shall have GFCI protection and be of the grounding type. (3) Other Receptacles, Location. Other receptacles shall be not less than 1.83 m (6 ft) from the inside walls of a pool. (4) GFCI Protection. All 15- and 20-ampere, single-phase,125-volt receptacles located within 6.0 m (20 ft) of the inside walls of a pool shall be protected by a ground fault circuit interrupter. FILE COPY WAYNE MARKHAM BENNEIT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD M85 JENSEN BEACH, FL 34W7-7212 2/11 /2022 (954) 818-3825 / wayna@wmbpe.com IF THERE IS A DIGITAL SIGNATURE ON THE FRONTIFIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET � IF SIGNED DIGITALLYABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED — i SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES Y POOL WASTE RETuiL VALVVEE W/ 32 PRESSURE GAUGE 6 I 11 I AIRRELI VALVE 331321 AQUASTAR 32" CDFL CHANNEL DRAIN (316 GPM ® 3.9 FTISEC THRU GRATE. PUMP W1 HAIR FINIS R SINGLE UNBLOCKABLE OR EQUAL LINTSTRAINER LOOR 3-WAY H DRAIN SUCTON LINE TIED OGETHER AS SHOWN ABOVE- 2 WAY PIPE SIZE PER PLAN r. 11 3-WAY 3-WAY IIII o = C 70 I I 1/2° ROCK BED CLOTH (RECOMMENDED) a m N NOTE: 252 SQ IN OPEN AREA, 9 HYDROSTATIC n 318 GPM = 3J! FEET PER SECOND a= w CHANNEL MAIN DRAIN DETAIL m 25 ALL POOL 6 SPA SUCTION INLETS SHALL BE PROVIDED WITH A COVER THAT HAS BEEN TESTED d ACCEPTED BY rP A RECOGNIZED TESTING FACILITY 6 COMPLY WITH ANSUASME A '112.19AM. ' SUCTION FIRINGS FOR USE IN 3 o� i z m m WATER BONDING FITTING o SWMING POOLS, SPAS, HOT TUBS 6 WHIRLPOOL BATHTUB APPLIANCES IN LINE CHLORINATOR 9 z z PB 20081" UL LISTED IOYZ NI D z : PERMACASTCOMPANY Pa z N W OD Q O Vac TOP OF AUTOMATIC FILLER BUCKET SHOUD BE FLUSH TO I" AUTOMATIC FlLLTER BUCKET PIPING SCHEMATIC ABOVE BOND BEAM MAXIMUM OWNWITHOUTCOVERRING BOND BEAM Y.° OVERFLOW PIPE N.T.S. PROPOSED AVERAGE POOL WATER TDH CALLS. (MIDDLE OF HE y * POOLTILE) PIPING & FITTINGS: 10 TDH 11P' FRESHWATER SUPPLY SUCTION CLEANER LINE FILTER:10 TDH ; CHLOR: 5 TDH vacUUM Flrnxc DETAIL TOTAL: 25 TDH WITH SELF CLOSING .4 ` III SAFETYOYER l��� VACUUM FITTING t 1 1 %," EQUALIZER PIPE GASKET AND SCREEN WITH SELF•CLOSING i�'• ;=: APSP/ANSI-1S FLOW CALCULATIONS PER STANDARD: POOL WATER VOLUME 8,556 /360= 36GPM CALCULATED FLOW RATE. NOTE POOLS UNDER 13,000 GALLONS, THE CALCULATED FLOW RATE OR 36 GPM WHICHEVER IS GREATER =THE FILTRATION FLOW RATE IS THERE AND AUXILIARY LOAD ON THE FILTRATION PUMP? NO IF SO, WHAT ISTHE CALCULATION AUXILIARY FLOW RATE: WA GPM MINIMUM FLOW RATE WA GPM (GREATER OF THE FILTRATION FLOW RATE OR THE AUX FLOW RATE IF THE AUX FLOW RATE IS POWERED BY THE FILTRATION PUMP) ALL LISTED BELOW PIPING IS FOR FILTRATION PUMP ONLY MINIMUM SUCTION PIPING SIZE @ 6 FPS 3 MINIMUM SUCTION BRANCH PIPE @ 8 FPS 3 MINIMUM RETURN PIPING SIZE @ 8 FPS 2.5MINIMUM RETURN BRANCH PIPE @ 8 FPS 2 FILTER TYPE AND SIZE: CARTRIDGE 340 SF MINIMUM FILTER AREA PER FILTER FACTOR IN STANDARD 340 X.375=128GPM (MAXIMUM FLOW THROUGH FILTER FACTOR: FILTER AREA X .375 (CART), X 2 (DE) OR X 1.5 (SAND) HEATER MAKE AND MODEL#: WA GAS HEATER EFFICIENCY RATING: WA (NO PILOT LIGHT) HEAT PUMP EFFICIENCY C.O.P.: WA PUMP SELECTION AS LISTED ON CURVE (A= <THAN 17,000 GAL OR C=> THAN 17,001 GAL) PUMP MAKE AND MODEL#: JANDYVSFHP165JEP 1.65THP FLOPRO VARIABLE SPEED PUMP FLOW RATE 33 GPM1,000 RPM (FLOW RATE MUST BE < OR = MAX FILTER FLOW RATE) PUMP CONTROLS= FILTRATION PUMP HAS NO AUX LOAD- STANDARD TIME CLOCK FILTRATION PUMP WITH AUXILIARY LOAD- CONTROL MODEL FOR LOW SPEED DEFAULT WITH 24HR BACKWASH VALVE: YES (IF YES, MUST BE 2" MINIMUM) APSP/ANSI-7 THIS DATA IS FOR THE: POOL SINGLE UNBLOCKABLE? YTWO OR MORE? N (IF SINGLE UNBLOCKABLE INDICATE MAKE AND MODEL NUMBER) DRAIN MAKE AND MODEL#: AQUASTAR 32" CHANNEL LISTED COVER FLOW RATE: 316 GPM SYSTEM FLOW RATE: 119 GPM METHOD DETERMINING FLOW RATE: MAX FLOW FROM PUMP CURVE PUMP MAKE AND MODEL#: JANDY VSFHP165JEP 1.65 THP FLOPRO VARIABLE SPEED PUMP SUCTION PIPING: BRANCH PIPING SIZE 3 INCH @ 6 FPS OR LOWERTRUNK PIPING SIZE 3 INCH @ 8 FPS OR LOWER AUTO FILL -BUCKET DETAIL T-40 N.T.S. (TO FILTER WEIR I','ISL:Tl;a4' SKIMMER DETAIL N.T.S. 119 PUMP FRAME FILTER TANK MOUNT / 13/1'X3118'TAPCON. Hum PUMP FIL ER FIBERMESH MAYBE USED IN LIEU OF WWF •� POOL PUMP, FILTER IIII ®I@ ANCHOR. POINTS (TYP.) FILE COPY POOL EQUIPMENT ANCHORING B SLAB DETAIL SEE NOTES PAGE N.T.S. DANIEL DUVERTON & VERONICA WAYNE MARKHAM BENNETT P.E. #57216 2990 JOHNSTON ROAD MARKHAM SERVICES, INC. (CA 33018) 182D NE JENSEN BEACH BLVD #685 FT PIERCE, FL 3051 ;� a �25 FL , 7 .— 2/7/2022 IF THERE IS A DIGITAL SIGNATURE ON THE FRONTIFIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET DRAFTED BY: G.S.M. AGE 4 OF 5 ESIGNER P'� IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENTARE NOTCONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES RESIDENTIAL POOL NOTES: GOVERNING CODES and GENERAL NOTES: 2020 Florida Building Code (FBC), 7t" Edition and all other codes, rules, regulations, and restrictions having jurisdiction on the project shall govern including FBC Th Edition Building, Residential, Fuel Gas and Energy Conservation FBC 7th Edition Energy Conservation C404.2, Service Water Heating Equipment Performance Efficiency: Gas Pool Heaters 82%, Heat Pump 4.0 COP, shall be met for this project FBC 70, Edition Residential Chapter 45: Swimming Pools and Building Chapter 4, Section 454 Swimming Pools and Bathing Places (Public and Private) shall specifically govern FBC 7th Edition 114501.6.1 Conformance Standard: Design, construction and workmanship shall be in conformity with the requirements of ANSIIAPSP/ICC 3; ANSUAPSP/ICC 4; ANSUAPSPIICC 5; ANSUAPSPI ICC 6; ANSUAPSPIICC 7 FBC 7th Edition Building Chapter 4, Section 454.1.6.5.10.4 If the area is subject to high ground water, the pool shall be designed to withstand hydraulic uplift or shall be provided with hydrostatic relief devices. FBC 7th Edition Section 454.2.21.4 and 1145011.211.4 Hydrostatic Relief Device. In areas of anticipated water table an approved hydrostatic relief device shall be installed FBC 7th Edition R4501.6.3 Water Velocity. Pool piping is designed so the water velocity will not exceed 10 feet per second for pressure piping and 8 feet per second for suction piping. Main suction outlet velocity must comply with ANSUAPSPIICC 7. Exception: Jet inlet fittings shall not be deemed subject to this requiremet Concrete shall conform to the latest edition of ACI 301 and ACI 318, with minimum 28-day compressive strength of 3,500 psi. Pool concrete can be applied pneumatically and shall conform to the latest edition of ACI 506.2 Reinforcing Steel shall conform to the latest edition of ASTM A615, Grade 40 (#3, #4), Grade 60 (#5) and have a minimum lap distance of 18' for #3, 24' for #4 and 30" for #5 to meet the requirements of the latest edition of ACI 318. Discontinuous reinforcement bars shall terminate in standard ACI hooks. All hooks are standard unless otherwise noted FBC 7th Edition Building 1903.3 Glass Fiber Reinforced Concrete GFRC and the materials used in such concrete shall be in accordance with the PC[ MNL 128 Standard, if shown on the drawings Pool Piping shall be N.S.F approved and minimum Schedule 40 NDPES: A silt fence and any other item, such as a construction entrance, with tire wash station shall be installed and inspected, if required, prior to construction surrounding the work area meeting the requirements of -the AHJ =OSHA 1926: Safety and Health Regulations for Construction shall be followed especially during open excavation and trenching Contractor shall be responsible to secure and protect all material brought on site, shall restore all areas impacted by the construction work to the preexisting condition or better and shall not impact drainagefiake, right of way or any other easements without consent Existing conditions, dimensions and quantities shall be field verged by Contractor prior to construction, as the Engineer has not been to the location. Typical field conditions are assumed in the design. Should anything differ from that specified herein or standard field conditions, additional engineering may be required and the Engineer shall be contacted to provide direction. Care shall be taken by Contractor in all applications of these drawings. The equipment and piping physical location may differ in the field due to unforeseen conditions or other factors. These drawings shall not be scaled, written dimensions shall take precedence. Contractor shall be responsible to locate and install items in a location that meets local codes These drawings are the property of Wayne Markham Bennett, P.E. Use of these drawings without permission from the Engineer is prohibited. The Engineer does not review the drawings for compliance with the agreement between Contractor and Homeowner. The Engineer is not responsible for any encroachment into easements or setbacks, even if approved by the AHJ. The Contractor shall verify compliance with setbacks and easements. The Engineer reviews the plans for code compliance to the best of his knowledge. Use of these drawings by the Contractor and Homeowner indemnifies and holds. harmless the Engineer for all costs and damages including legal fees resulting from material fabrication, system erection and construction practices beyond which is called for Local, State and Federal Codes and from deviations of these plans except as expressly provided herein. The Engineer is not responsible for and has no liability for construction in setbacks or easements, and Contractor and/or Homeowner requirements and/or agreements related to the Pool and/or Spa. Regardless of cause, the Engineer's Liability in relation to these plans is limited to the lesser of $500 or the fee charged by the Engineer for these plans. WARNING: To empty pool of water after construction for any reason, the hydrostatic uplift pressures beneath the pool must be eliminated to prevent the pool from floating upward. Owner must consult a pool contractor experienced in eliminating uplift pressure POOL EQUIPMENT and ANCHORING: Pool Equipment Elevation shall be at a minimum of the Design Flood Elevation (FBC 7th Edition Residential 11322.1.4) plus 1 foot or according to the Authority Having Jurisdiction FBC 7th Edition Building 1620 HVHZ Wind Loads and 1621 HVHZ Overturning Moment and Uplift Pool Equipment shall be designed, constructed and installed to meet the requirements of ASCE 7. Equipment tie down shall be as follows, Heaters 4 total (1 per side or 2 per opposite sides); Others 2 total: 3-1 Z minimum thick, 3000 psi concrete slab, 3° larger than on each side than the equipment; %a diameter Tapcon® Concrete Screws (1600# tension, 1290# shear, /-1/2" embedment in 2000 psi concrete) or equal with stainless steel fender washer into factory provided hold downs or 1° wide, 14 gauge galvanized straps with 2 stainless steel, #10 x Y47 Pan Head Phillips SS screws each strap into metal frame of equipment FBC 7th Edition Building 1907.1 General The thickness of concrete equipment slab supported directly on the ground shall not be less than 3-1/2 inches thick and shall not require a vapor barrier. Equipment Location and Screening: The equipment and piping physical location may differ in the field due to unforeseen conditions or other factors. Contractor shall be responsible to locate and install items in a location that meets local zoning code and to provide code compliant landscape or fence screening FBC 7w Edition Residential R4501.17 Residential Swimming Barrier Requirement Residential swimming pools shall comply with Sections R4501.17.1 through R4501.17.3. Exception: A swimming pool with an approved safety pool cover complying with ASTM F1346 FBC Ph Edition Residential 1146011.117.1 Outdoor Swimming Pools Outdoor swimming pools shall be provided with a barrier complying with R4501.17.1.1 through R4501.17.1.14 A Swimming Barrier around the pool area that meets the above code is required prior to final pool structural inspection and filling of the pool FLOOD ZONE: FBC Ph Edition Residential R322 Flood -Resistant Construction structures constructed in whole or part in flood hazard areas shall be designed and constructed in accordance with the provisions of this section, especially R322.1.2 Structural Systems, 322.1.3 Flood -Resistant Construction and R322.2.5 Pools in Flood Hazard Areas. If structures constructed in whole or part in floodways shall be designed and constructed in accordance with ASCE 24 and the construction of this pool will not increase the design flood elevation SOIL BEARING and FOUNDATION NOTES: No Piles and without Soil Report: FBC 7t^ Edition Building 1803 Geotechnical Investigations: The Building Official shall be permitted to waive the requirement. Allowable Bearing Capacity: Based on rational analysis through knowledge of other projects in the vicinity and a visual examination of the surface soil, finding sand and rock, the pool foundation has been designed assuming 2,000 psf soil bearing capacity per Table R401.4.1. If during excavation deleterious material (such as sift, peat, muck, clay, etc.) is found that cannot provide 2,000 psf, the Engineer shall be contacted to provide direction FILE COPY DANIEL DUVERTON & VERONICA WAYNEMARKHAMBENNETTP.E.N57218 2990 JOHNSTON ROAD MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 °;�25/ FL tit 1/2022 FT PIERCE, FL U951 (� .�, IF THERE IS A DIGITAL SIGNATURE ON THE FRONTIFIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET DRAFTED BY. G.S.M. AGE 5 OF 5 I ESIGNER OTES I IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES