HomeMy WebLinkAboutProject Information-�-'wrightsoft° Project Summary Job: : Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772466.6799 Emall: QUICKCALCS@AOL.COM For. ROTHADDITION 1817 HAZELWOOD DRIVE, FT. PIERCE, FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 7831 Btuh Structure 7413 Btuh Ducts 1056 Btuh Duds 1354 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping qu pment load 8888 �h Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 8328 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 884 Btuh 410 Central vent (0 cfm) Btuhth Heating Cooling (none) Area (fib 496 496 Equipment latent load 1295 Btuh Volume (it3) 3968 3968 Air changes/hour 0.61 0.32 Equipment Total Load (Sen+Lat) 9624 Btuh Equiv. AVF (crm) 40 21 Req. total capacity at 0.70 SHR 1.0 ton Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MUZ-HMI2NAH*** Cond MUZ-HM12NAH*** AHRI ref 202680605 Coil MSZ-HM12NA*** AHRI ref 202680605 Efficiency 9 HSPF Efficiency 9.9 EER,18 SEER Heating input Sensible cooling 8400 Btuh Heating output 12200 Btuh @ 47°F Latent cooling 3600 Btuh Temperature rise 28 OF Total cooling 12000 Btuh Actual airflow 400 din Actual airflow 400 cam Airflowfactor 0.045 cfm/Btuh Airflowfactor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Capaci thermostat Load sensible heat ratio 0.87 lace point = 34 °F Backup: ~ Input = 3 kW, Output = 8889 Btuh, 100AFUE COPY Calculations approved byACCA to meet all requirements of Manual J 8th Ed. C -O &- =19htsc ft- r R1grt•SLdte9Uriversa12021 21.0.08 RSU08101 2022-Jan14 09:5537 Page 1 C:1Users\QUICK1DovioadslROTHAODR10N.np Calc-MJ8 FrontDoorfaoes: E -�- wrightsofte Right-JO Worksheet Job; Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone:772-466.6799 Email; QUICKCALCS@AOL.COM 1 Room name Entire House GARAGE 2 Exposed vvall 85.0 It 85.0 it 3 Room height 8.0 It 8.0 It heatkod 4 Room dimensions 1.0 x 496.0 ft 5 Room area 496.0 ft 496.0 fe Ty Construction U-value or HTM Area (ft) Load Area (� Load number (BtuhW-TF) (Btu hlR� or perimeter M (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross NIPIS Heat Cod Gross N/P/S Heat Cool 6 Upl 13A-7.5ocs 0,095 n 2.66 126 256 144 383 182 256 144 383 182 �—D 11J0. 0.600 n 16.80 15.90 112 112 1862 1781 112 112 1882 1781 w 13A-7.5ocs 0.095 a 2.66 126 168 168 447 212 168 168 447 212 w 13A•7.5om 0.095 s 2.66 126 88 88 234 111 88 Be 234 111 11 w 13A-7.5ocs 0.095 w 2.66 126 168 138 367 174 168 138 367 174 " 1 D-c2ow 0.570 w 16.96 59.33 30 2 479 1780 30 2 479 1780 C 166.30ad 0.032 - Oleo 1.60 496 496 444 794 496 496 444 794 F 22A•tpl 0.989 - 27.69 0.00 496 85 2364 0 496 85 2354 0 6 c) AED excursion 1030 1030 Envelope loss(gain 6590 6064 6590 6064 12 a) Infiltration 1241 349 1241 349 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 ApplianoWother 1000 1 1000 Subtotal Qines6 to 13) 7831 7413 7831 7413 LesseMemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 7831 7413 7831 7413 15 DUdloads 13% 18%1 1056 1354 130/0 18% 1056 1354 Total room load 8888 8767 1 8888 8767 Air required (c m) 400 400 400 400 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ -R� wrigFftsott� 2022-Jarr1409:55:37 f2igft-Suite® Universal 2021 21.0.08 RSU08101 Page 1 C:\Users\OUICK\DovMoads\ROTHADDRIONxW Calc-MJ8 FrortDoorfaces: E Job M Performed for. ROTH ADDITION 1817 HAZELWOOD DRIVE FT. PIERCE, FL Sheet1 QUICK CALCS, INC. 317 ST. LUCE LANE FL PIERCE, FL34946 Phone: 772466-6799 QUICKCALCS@AOLCOM Scale: 1 :118 Page 1 Right-SufteS Universal2021 21.0.08 RSU08101 2022-Jan-14 09:55:64 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ROTH ADDITION Builder Name: EMIL IYVOLA Street: 1817 HAZELWOOD DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: CHARLIE & LORI Jurisdiction: 661000 Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing Addition 10. Wall Types(680.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, ExterioR=9.0 680.00 fe b. N/A R= ftz 3. Number of units, if multiple family 1 c. N/A R= it 4. Number of Bedrooms 0 d. N/A R= ftz 5. Is this a worst case? No 11. Ceiling Types(496.0 sgft.) Insulation Area 6. Conditioned floor area above grade (ftz) 496 a. Under Attic (Vented) R=30.0 496.00 ftzb. R= Conditioned floor area below grade (W) 0 N/A c. N/A ftz R= ftz 7. Windows(30.0 sgft.) Description Area 12. Ducts, location & insulation level R ftz a. U-Factor: Sgl, U=0.65 30.00 ftz a. SHGC: SHGC=0.25 b. b. U-Factor: N/A ftz C. SHGC: 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: N/A ftz a. Central Unit 12.0 SEER:18.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft Area Weighted Average SHGC: 0.250 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Heat Pump 12.0 HSPF:9.00 U-Factor:(AVG) N/A N/A ftz SHGC(AVG): N/A 9. Floor Types Insulation Area 15. Hot Water Systems -None required a. Slab -On -Grade Edge Insulation R= 0.0 496.00 ftz a°e Cap: N/A p z ftz b. Conservation features c. N/A R= 16. Credits None Glass/Floor Area:0.060 Total Proposed Modified Loads: 11.32 PASS Total Baseline Loads: 15.43 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this piC�K� SrArA Code. calculation indicates compliance with the Florida Energy Code. fill,i' PREPARED BY: Before construction is completed this building will be inspected for %94 DATE: 1-14-2022 compliance with Section 553.908 Florida Statutes. I hereby certify that this building, as designed, is in compliance'c000`'S with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factorysealed in accordance with R403.3.2.1. - Proposed Qn of NAN exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405.2.3 - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 1/14/2022 9:48:27 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: ROTH ADDITION Building Type: User Owner: CHARLIE & LORI BuilderName: EMIL IYVOLA Permit Office: ST. LUCIE COUNTY Jurisdiction: 661000 FamilyType: Detached New/Existing: Addition YearConstruct: Comment: Bedrooms: 0 ConditionedArea: 496 Total Stories: 1 Worst Case: No RotateAngle: 0 CrossVentilation: No Whole House Fan: No Terrain: Suburban Shielding: Suburban Addresstype: StreetAddress Lot#: -- Block/SubDivislon: -- PlatBook: --- Street: 1817 HAZELWOOD DRIVE County: St. Lucie City, State, Zip: FT. PIERCE, FL, CLIMATE Design Location TmySite Design Temp Int Design Temp Heating Design Daiiytemp 97.5% 2.5% Winter Summer Degree Days Moisture Range _ FL, Fort Pierce FL VERO_BEACH MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume _1 Entire House 496 3968 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated 1 GAR 496 3968 No 0 Yes Yes Yes FLOORS (Total Exposed Area = 496 sq.ft.) # FloorType Space Exposed Perim PerimeterR-Value Area U-Factor JoistR-Value Tile Wood Carpet —1 Slab -On -Grade Edge Ins GAR 85 0 496 ft 0.473 --- 0.00 1.00 0.00 ROOF ` / V # Type Materials Roof Gable Roof Area Area Color Red Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) _ 1 Hip Compositionshingles 523 ft2 0 ft2 Medium N 0.6 No 0.6 No 0 18.43 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 496 ft2 N N CEILING (Total Exposed Area = 496 sq.ft.) # Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type _ 1 UnderAttic(Vented) GAR 30.0 Blown 496.0ft2 0.053 0.10 Wood 1 /14/2022 9:48:27 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS (Total Exposed Area = 680 sq.ft.) # Adjacent Cavity Width Omt To Wall Type Space R-Value Ft In Height Area U- Sheath Frm. Solar Below Ft In sq.ft. Factor R-Value Frac. Absor. Grade _ 1 _ 2 _ 3 4 N Exterior Conc. Blk - Ext Ins E Exterior Conc. Blk - Ext Ins S Exterior Conc. Blk - Ext Ins W Exterior Conc. Blk - Ext Ins GAR 9.0 32.0 0 GAR 9.0 21.0 0 GAR 9.0 11.0 0 GAR 9.0 21.0 0 8.0 0 256.0 0.080 0 0 0.50 0 % 8.0 0 168.0 0.080 0 0 0.50 0 % 8.0 0 88.0 0.080 0 0 0.50 0 % 8.0 0 168.0 0.080 0 0 0.50 0 % DOORS (Total Exposed Area = 112 sq.ft.) J# Omt Adjacent To DoorType Space Storms Width Height U-Value Ft In Ft In Area 1 N Insulated GAR None 0.38 16.00 0 7.00 0 112.0ft2 WINDOWS (Total Exposed Area = 30 sq.ft.) J# Wall --Overhang--- Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation InteriorShade Screening 1 W 4 Metal Low-E Single Yes 0.65 0.25 Y N 30.0ft' 2.0 ft 0 in 1.0 ft 4 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) _ 1 Wholehouse ProposedACH(50) 0.00025 331 18.14 34.06 0.0902 5.0 All MASS # Mass Type Area Thickness Furniture Fraction Space _ 1 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 GAR HEATING SYSTEM # SystemType/Fl.Addition Subtype/Speed AHRI # Efficiency Capacity--GeothermalHeatPump--- Ducts Block kBtu/hr Entry Power Volt Current _ 1 Electric Heat Pump/Supplementa Split/Single HSPF: 9,00 12.0 0.00 0.00 0.00 sys#0 1 COOLING SYSTEM # SystemType/FI.Addition Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm ,1 Central Unit/Supplementa Split/Single SEER:18.0 12.0 0 0.70 Ductless 1 1 /14/2022 9:4827 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # SystemType Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipelength Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff DUCTS --------Supply---- ------Retum-------- Air CFM 25 CFM 25 HVAC # JDuct # Location R-Value Area Location R-Value Area LeakageType Handier TOT OUT QN RLF Heat Coot TEMPERATURES ProgramableThermostat: N Ceiling Fans: N Cooling []Jan [ ]Feb [ ] Mar [ I Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep I] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ]may []Jun []Jul [ ] Aug []Sep [ ] Oct [XI Nov [XI Dec Venting []Jan [ ]Feb [X] Mar [XI Apr [] May []Jun []Jul [ ] Aug [ ]Sep [X] Oct [X] Nov []Dec Thermostat Schedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 T Cooling (WD) AM PM 78 80 78 80 78 78 78 80 80 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 _ Cooling (WEH) AM PM 78 80 78 80 78 78 78 80 80 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 _ Heating (WD) AM PM 65 68 65 68 65 65 65 68 68 68 65 68 65 68 68 68 68 6B 68 68 68 68 68 68 Heating (WEH) AM PM 65 68 65 68 65 65 65 68 68 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 1/14/2022 9:48:27 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ROTH ADDITION Builder Name: EMIL IYVOLA Street: 1817 HAZELWOOD DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: CHARLIE & LORI Jurisdiction: 661000 v Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air bardershail be Installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls Thejunction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exteriorthermal envelope insulation forframed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floorframing cavity insulation shall be installed to (including insulation. maintain permanent contactwith the underside of above -garage subfloor decking, orfloor framing cavity insulation andcantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeterfloor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrowcavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conformstothe available cavity spaces. Garageseparation Air sealing shall be provided between the garage and conditionedspaces. Recessed lighting Recessed light fixtures installed In the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on Installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exteriorwalls adjacent to showers Exteriorwalls adjacent to showers and tubs shall onexteriorwali and tubs shall separate them from the showers and tubs. beinsulated. Electrical/phonebox The air barrier shall be installed behind electrical or onexteriorwalls communication boxes orair-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1/14/2022 9:48:27 AM EnergyGaugeO USA 7.0 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 R W R `1V Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Registry License No. 9813 Product Sub Category Manufacturer Product Name Category Plastpro Inc. Opaque Fiberglass Single Door Exterior Swinging Exterior Door 5200 W. Century Blvd. w/ or w/out Sidelites Doors Assemblies Los Angeles, CA 90045 Inswing I Outswing (440) 969-9773 1 "Impact' Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID # 1998) for Plastpro Inc. based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 7th Edition (2020) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone". 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM El996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-17184.5 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-17184.5 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 2005-02-21-001 ASTM E330-02, ASTM E1996/1886-02 Testing Evaluation Lab.,lnc. V.K. Wright TEL 01390365 TEL 2004-07-13-016 TAS 201, 202, 203-94 ASTM E330-02, ASTM E1996/1886-02 Testing Evaluation Lab -Inc. Lyndon F. Schmidt, P.E. . Testing Evaluation Lab.,lnc. V.K. Wright 2. Miami Dade NOA Materials GO? 18-0301.05 Saflex® PVB Interlayers (Eastman Chemical Company) �®�� 3. Drawing No. Prepared by Signed & Sealed by No. FL-17184.5 RW Building Consultants, Inc. (CA #9813) Lyndon F. Schmidt, P.E. 4. Calculations Prepared by b�gtG89Qnug�n a • � �,'{ 3 ��eoSigned & Sealed by o ' Anchoring RW Building Consultants, Inc. (CA #9813) �o�o °��,G `= S ° , C9ndon F. Schmidt, P.E. ° e°0"34 0D °o 5. Quality Assurance _� ` Certificate of Participation issued by National Accreditation and Management Institute, certifying that Plastpro Inc. is manufacturing products within a --u; !11 quality assurance program that complies with ISO/IEC 17020 and Guide 53. r �, t ;'; :v C 2 <" ° ,� Lyndon F. Schmidt, P.E. o ° �`•;��° FL PE No. 43409 ill P, 8/7/2020 Sheet 1 of 1 ;+:• 4ay��J3&LEdtiha�a�