HomeMy WebLinkAboutProject Information-�-'wrightsoft° Project Summary Job:
:
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772466.6799 Emall: QUICKCALCS@AOL.COM
For. ROTHADDITION
1817 HAZELWOOD DRIVE, FT. PIERCE, FL
Notes:
Weather: Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42 OF
Outside db
90
OF
Inside db 70 OF
Inside db
75
OF
Design TD 28 OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
grAb
Heating Summary
Sensible Cooling Equipment Load
Sizing
Structure 7831 Btuh
Structure
7413
Btuh
Ducts 1056 Btuh
Duds
1354
Btuh
Central vent (0 cfm) 0 Btuh
Central vent (0 cfm)
0
Btuh
(none)
(none)
Humidification 0 Btuh
Blower
0
Btuh
Piping
qu pment load 8888 �h
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
8328
Btuh
Method Simplified
Latent Cooling Equipment
Load Sizing
Construction quality Average
Fireplaces 0
Structure
884
Btuh
410
Central vent (0 cfm)
Btuhth
Heating Cooling
(none)
Area (fib 496 496
Equipment latent load
1295
Btuh
Volume (it3) 3968 3968
Air changes/hour 0.61 0.32
Equipment Total Load (Sen+Lat)
9624
Btuh
Equiv. AVF (crm) 40 21
Req. total capacity at 0.70 SHR
1.0
ton
Heating Equipment Summary
Cooling Equipment Summary
Make Mitsubishi Electric
Make Mitsubishi Electric
Trade Mitsubishi Electric
Trade Mitsubishi Electric
Model MUZ-HMI2NAH***
Cond MUZ-HM12NAH***
AHRI ref 202680605
Coil MSZ-HM12NA***
AHRI ref 202680605
Efficiency 9 HSPF
Efficiency 9.9 EER,18 SEER
Heating input
Sensible cooling
8400
Btuh
Heating output 12200 Btuh @ 47°F
Latent cooling
3600
Btuh
Temperature rise 28 OF
Total cooling
12000
Btuh
Actual airflow 400 din
Actual airflow
400
cam
Airflowfactor 0.045 cfm/Btuh
Airflowfactor
0.046
cfm/Btuh
Static pressure 0 in H2O
Static pressure
0
in H2O
Capaci thermostat
Load sensible heat ratio
0.87
lace point = 34 °F
Backup:
~ Input = 3 kW, Output = 8889 Btuh, 100AFUE
COPY
Calculations approved byACCA to meet
all requirements of Manual J 8th Ed.
C -O &- =19htsc ft-
r R1grt•SLdte9Uriversa12021 21.0.08 RSU08101
2022-Jan14 09:5537
Page 1
C:1Users\QUICK1DovioadslROTHAODR10N.np Calc-MJ8 FrontDoorfaoes: E
-�- wrightsofte Right-JO Worksheet Job;
Entire House Date:
QUICK CALCS, INC. By:
317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone:772-466.6799 Email; QUICKCALCS@AOL.COM
1
Room name
Entire House
GARAGE
2
Exposed vvall
85.0 It
85.0 it
3
Room height
8.0 It
8.0 It heatkod
4
Room dimensions
1.0 x 496.0 ft
5
Room area
496.0 ft
496.0 fe
Ty
Construction
U-value
or
HTM
Area (ft)
Load
Area (�
Load
number
(BtuhW-TF)
(Btu hlR�
or perimeter M
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cod
Gross
NIPIS
Heat
Cod
Gross
N/P/S
Heat
Cool
6
Upl
13A-7.5ocs
0,095
n
2.66
126
256
144
383
182
256
144
383
182
�—D
11J0.
0.600
n
16.80
15.90
112
112
1862
1781
112
112
1882
1781
w
13A-7.5ocs
0.095
a
2.66
126
168
168
447
212
168
168
447
212
w
13A•7.5om
0.095
s
2.66
126
88
88
234
111
88
Be
234
111
11
w
13A-7.5ocs
0.095
w
2.66
126
168
138
367
174
168
138
367
174
"
1 D-c2ow
0.570
w
16.96
59.33
30
2
479
1780
30
2
479
1780
C
166.30ad
0.032
-
Oleo
1.60
496
496
444
794
496
496
444
794
F
22A•tpl
0.989
-
27.69
0.00
496
85
2364
0
496
85
2354
0
6
c) AED excursion
1030
1030
Envelope loss(gain
6590
6064
6590
6064
12
a) Infiltration
1241
349
1241
349
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
ApplianoWother
1000
1 1000
Subtotal Qines6 to 13)
7831
7413
7831
7413
LesseMemalload
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
7831
7413
7831
7413
15
DUdloads
13%
18%1
1056
1354
130/0
18%
1056
1354
Total room load
8888
8767
1
8888
8767
Air required (c m)
400
400
400
400
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
_ -R� wrigFftsott� 2022-Jarr1409:55:37
f2igft-Suite® Universal 2021 21.0.08 RSU08101 Page 1
C:\Users\OUICK\DovMoads\ROTHADDRIONxW Calc-MJ8 FrortDoorfaces: E
Job M
Performed for.
ROTH ADDITION
1817 HAZELWOOD DRIVE
FT. PIERCE, FL
Sheet1
QUICK CALCS, INC.
317 ST. LUCE LANE
FL PIERCE, FL34946
Phone: 772466-6799
QUICKCALCS@AOLCOM
Scale: 1 :118
Page 1
Right-SufteS Universal2021
21.0.08 RSU08101
2022-Jan-14 09:55:64
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: ROTH ADDITION
Builder Name: EMIL IYVOLA
Street: 1817 HAZELWOOD DRIVE
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: CHARLIE & LORI
Jurisdiction: 661000
Design Location: FL, Fort Pierce
County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing
Addition
10. Wall Types(680.0 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Ext Insul, ExterioR=9.0 680.00 fe
b. N/A
R= ftz
3. Number of units, if multiple family
1
c. N/A
R= it
4. Number of Bedrooms
0
d. N/A
R= ftz
5. Is this a worst case?
No
11. Ceiling Types(496.0 sgft.)
Insulation Area
6. Conditioned floor area above grade (ftz)
496
a. Under Attic (Vented)
R=30.0 496.00 ftzb.
R=
Conditioned floor area below grade (W)
0
N/A
c. N/A
ftz
R= ftz
7. Windows(30.0 sgft.) Description
Area
12. Ducts, location & insulation level R ftz
a. U-Factor: Sgl, U=0.65
30.00 ftz
a.
SHGC: SHGC=0.25
b.
b. U-Factor: N/A
ftz
C.
SHGC:
13. Cooling Systems
kBtu/hr Efficiency
c. U-Factor: N/A
ftz
a. Central Unit
12.0 SEER:18.00
SHGC:
Area Weighted Average Overhang Depth:
2.000 ft
Area Weighted Average SHGC:
0.250
14. Heating Systems
kBtu/hr Efficiency
8. Skylights Description
Area
a. Electric Heat Pump
12.0 HSPF:9.00
U-Factor:(AVG) N/A
N/A ftz
SHGC(AVG): N/A
9. Floor Types Insulation
Area
15. Hot Water Systems -None required
a. Slab -On -Grade Edge Insulation R= 0.0
496.00 ftz
a°e
Cap: N/A
p
z
ftz
b. Conservation features
c. N/A R=
16. Credits
None
Glass/Floor Area:0.060 Total Proposed Modified Loads: 11.32
PASS
Total Baseline
Loads: 15.43
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida
Energy
specifications covered by this
piC�K� SrArA
Code.
calculation indicates compliance
with the Florida Energy Code.
fill,i'
PREPARED BY:
Before construction is completed
this building will be inspected for
%94
DATE: 1-14-2022
compliance with Section 553.908
Florida Statutes.
I hereby certify that this building, as designed, is in compliance'c000`'S
with the Florida Energy Code.
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factorysealed in accordance with R403.3.2.1.
- Proposed Qn of NAN exceeds the performance method default limit of 0.08
and therefore does not require duct testing. R405.2.3
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
1/14/2022 9:48:27 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: ROTH ADDITION
Building Type: User
Owner: CHARLIE & LORI
BuilderName: EMIL IYVOLA
Permit Office: ST. LUCIE COUNTY
Jurisdiction: 661000
FamilyType: Detached
New/Existing: Addition
YearConstruct:
Comment:
Bedrooms: 0
ConditionedArea: 496
Total Stories: 1
Worst Case: No
RotateAngle: 0
CrossVentilation: No
Whole House Fan: No
Terrain: Suburban
Shielding: Suburban
Addresstype: StreetAddress
Lot#: --
Block/SubDivislon: --
PlatBook: ---
Street: 1817 HAZELWOOD DRIVE
County: St. Lucie
City, State, Zip: FT. PIERCE,
FL,
CLIMATE
Design
Location
TmySite
Design Temp Int Design Temp Heating Design Daiiytemp
97.5% 2.5% Winter Summer Degree Days Moisture Range
_ FL, Fort Pierce
FL VERO_BEACH MUNICIPA 39 90
70 75 299 62 Low
BLOCKS
Number Name
Area
Volume
_1 Entire House
496
3968
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms Finished Cooled Heated
1 GAR
496
3968 No 0
Yes Yes Yes
FLOORS
(Total Exposed Area = 496 sq.ft.)
# FloorType
Space
Exposed Perim PerimeterR-Value
Area U-Factor JoistR-Value Tile Wood Carpet
—1 Slab -On -Grade Edge Ins
GAR
85 0
496 ft 0.473 --- 0.00 1.00 0.00
ROOF
` /
V # Type
Materials
Roof Gable Roof
Area Area Color
Red Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
_ 1 Hip
Compositionshingles 523 ft2 0 ft2 Medium
N 0.6 No 0.6 No 0 18.43
ATTIC
# Type
Ventilation Vent Ratio (1 in) Area RBS IRCC
1 Full attic
Vented
150 496 ft2 N N
CEILING
(Total Exposed Area = 496 sq.ft.)
# Ceiling Type
Space R-Value Ins. Type
Area U-Factor Framing Frac. Truss Type
_ 1 UnderAttic(Vented)
GAR 30.0 Blown
496.0ft2 0.053 0.10 Wood
1 /14/2022 9:48:27 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
(Total Exposed Area = 680 sq.ft.)
#
Adjacent Cavity Width
Omt To Wall Type Space R-Value Ft In
Height Area U- Sheath Frm. Solar Below
Ft In sq.ft. Factor R-Value Frac. Absor. Grade
_ 1
_ 2
_ 3
4
N Exterior Conc. Blk - Ext Ins
E Exterior Conc. Blk - Ext Ins
S Exterior Conc. Blk - Ext Ins
W Exterior Conc. Blk - Ext Ins
GAR 9.0 32.0 0
GAR 9.0 21.0 0
GAR 9.0 11.0 0
GAR 9.0 21.0 0
8.0 0 256.0 0.080 0 0 0.50 0 %
8.0 0 168.0 0.080 0 0 0.50 0 %
8.0 0 88.0 0.080 0 0 0.50 0 %
8.0 0 168.0 0.080 0 0 0.50 0 %
DOORS
(Total Exposed Area = 112 sq.ft.)
J#
Omt Adjacent To DoorType Space Storms
Width Height
U-Value Ft In Ft In Area
1
N Insulated GAR None
0.38 16.00 0 7.00 0 112.0ft2
WINDOWS
(Total Exposed Area = 30 sq.ft.)
J#
Wall --Overhang---
Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation InteriorShade Screening
1 W 4 Metal Low-E Single Yes 0.65 0.25 Y N 30.0ft' 2.0 ft 0 in 1.0 ft 4 in None None
INFILTRATION
#
Scope Method SLA
CFM50 ELA EgLA
ACH ACH50 Space(s)
_ 1
Wholehouse ProposedACH(50) 0.00025
331 18.14 34.06
0.0902 5.0 All
MASS
#
Mass Type Area
Thickness
Furniture Fraction Space
_ 1
Default(8lbs/sq.ft.) 0 ft2
0 ft
0.30 GAR
HEATING SYSTEM
#
SystemType/Fl.Addition Subtype/Speed
AHRI # Efficiency Capacity--GeothermalHeatPump--- Ducts Block
kBtu/hr Entry Power Volt Current
_ 1
Electric Heat Pump/Supplementa Split/Single
HSPF: 9,00
12.0 0.00 0.00 0.00 sys#0 1
COOLING SYSTEM
#
SystemType/FI.Addition Subtype/Speed
AHRI # Efficiency
Capacity Air Flow SHR Duct Block
kBtu/hr cfm
,1
Central Unit/Supplementa Split/Single
SEER:18.0
12.0 0 0.70 Ductless 1
1 /14/2022 9:4827 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3
FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# SystemType
Subtype
Location
EF(UEF) Cap
Use
SetPnt
Fixture Flow Pipe Ins.
Pipelength
Recirculation
Recirc Control
Loop Branch Pump
DWHR
Facilities Equal DWHR
Other Credits
System
Type
length length power
Connected Flow
Eff
DUCTS
--------Supply----
------Retum--------
Air
CFM 25
CFM 25
HVAC #
JDuct
# Location
R-Value
Area Location R-Value Area LeakageType
Handier
TOT
OUT
QN
RLF Heat Coot
TEMPERATURES
ProgramableThermostat: N
Ceiling Fans: N
Cooling []Jan
[ ]Feb
[ ] Mar
[ I Apr
[ ] May [X] Jun
[X] Jul
[X] Aug
[X] Sep
I] Oct
[ ]
Nov
[ ] Dec
Heating [X] Jan
[X] Feb
[X] Mar
[ ] Apr
[ ]may []Jun
[]Jul
[ ] Aug
[]Sep
[ ] Oct
[XI Nov
[XI Dec
Venting []Jan
[ ]Feb
[X] Mar
[XI Apr
[] May []Jun
[]Jul
[ ] Aug
[ ]Sep
[X] Oct
[X] Nov
[]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
ScheduleType
1
2
3 4 5
6
7
8
9
10
11
12
T Cooling (WD)
AM
PM
78
80
78
80
78 78 78
80 80 78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
_ Cooling (WEH)
AM
PM
78
80
78
80
78 78 78
80 80 78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
_ Heating (WD)
AM
PM
65
68
65
68
65 65 65
68 68 68
65
68
65
68
68
68
68
6B
68
68
68
68
68
68
Heating (WEH)
AM
PM
65
68
65
68
65 65 65
68 68 68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
1/14/2022 9:48:27 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: ROTH ADDITION Builder Name: EMIL IYVOLA
Street: 1817 HAZELWOOD DRIVE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number: Y
Owner: CHARLIE & LORI Jurisdiction: 661000 v
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air bardershail be Installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks orjoints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
Thejunction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per
Knee walls shall be sealed.
inch minimum
Exteriorthermal envelope insulation forframed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floorframing cavity insulation shall be installed to
(including
insulation.
maintain permanent contactwith the underside of
above -garage
subfloor decking, orfloor framing cavity insulation
andcantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeterfloor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered
Where provided instead of floor insulation, insulation
with a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrowcavities
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
installation readily conformstothe available cavity
spaces.
Garageseparation
Air sealing shall be provided between the garage and
conditionedspaces.
Recessed lighting
Recessed light fixtures installed In the building thermal
Recessed light fixtures installed in the building
envelope shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
Installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exteriorwalls adjacent to showers
Exteriorwalls adjacent to showers and tubs shall
onexteriorwali
and tubs shall separate them from the showers and tubs.
beinsulated.
Electrical/phonebox
The air barrier shall be installed behind electrical or
onexteriorwalls
communication boxes orair-sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering
or ceiling penetrated by the boot.
Concealed
When required to be sealed, concealed fire sprinklers shall only
sprinklers
be sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
voids between fire sprinkler cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
1/14/2022 9:48:27 AM EnergyGaugeO USA 7.0 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1
R W R `1V Building Consultants, Inc.
BConsulting and Engineering Services for the Building Industry
C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197
Florida Board of Professional Engineers Registry License No. 9813
Product
Sub Category
Manufacturer
Product Name
Category
Plastpro Inc.
Opaque Fiberglass Single Door
Exterior
Swinging
Exterior Door
5200 W. Century Blvd.
w/ or w/out Sidelites
Doors
Assemblies
Los Angeles, CA 90045
Inswing I Outswing
(440) 969-9773
1 "Impact'
Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID #
1998) for Plastpro Inc. based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval,
Department of Business & Professional Regulation.
RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein.
Limitations:
1. This product has been evaluated and is in compliance with the 7th Edition (2020) Florida Building Code (FBC) structural requirements
excluding the "High Velocity Hurricane Zone".
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does
not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM El996 and
FBC Sections 1609.1.2.2 & R301.2.1.2.1.
4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction.
5. Site conditions that deviate from the details of drawing FL-17184.5 require further engineering analysis by a licensed engineer or
registered architect.
6. See drawing FL-17184.5 for size and design pressure limitations.
Supporting Documents:
1. Test Report No.
Test Standard
Testing Laboratory Signed by
TEL 2005-02-21-001
ASTM E330-02, ASTM E1996/1886-02
Testing Evaluation Lab.,lnc. V.K. Wright
TEL 01390365
TEL 2004-07-13-016
TAS 201, 202, 203-94
ASTM E330-02, ASTM E1996/1886-02
Testing Evaluation Lab -Inc. Lyndon F. Schmidt, P.E.
.
Testing Evaluation Lab.,lnc. V.K. Wright
2. Miami Dade NOA
Materials
GO?
18-0301.05
Saflex® PVB Interlayers (Eastman Chemical Company) �®��
3. Drawing No.
Prepared by
Signed & Sealed by
No. FL-17184.5
RW Building Consultants, Inc. (CA #9813)
Lyndon F. Schmidt, P.E.
4. Calculations
Prepared by
b�gtG89Qnug�n
a • � �,'{ 3 ��eoSigned & Sealed by
o '
Anchoring
RW Building Consultants, Inc. (CA #9813)
�o�o °��,G `= S ° , C9ndon F. Schmidt, P.E.
° e°0"34 0D °o
5. Quality Assurance
_� `
Certificate of Participation issued by National Accreditation and Management
Institute, certifying that Plastpro
Inc. is manufacturing products within a
--u;
!11
quality assurance program that complies with ISO/IEC 17020 and Guide 53.
r �, t ;'; :v C 2 <"
° ,� Lyndon F. Schmidt, P.E.
o °
�`•;��° FL PE No. 43409
ill P, 8/7/2020
Sheet 1 of 1
;+:•
4ay��J3&LEdtiha�a�