Loading...
HomeMy WebLinkAboutProduct Approval Window Single HungFlorida Building Code Online https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGE... s �( BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications I Contact Us BCIS Site Map L Florida 4Product Approval USER: Public User R�str�ii�;Wtv� Product Approval Menu > Product or Application Search > Application List > Application Detail t5R"1� Ik FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) FL14911-R12 Revision 2020 Approved D Silver Line Building Products Corp. One Silverline Drive North Brunswick, NJ 08902 (800)542-9118 Ext413596 luanne.harris@cornerstone-bb.com Luanne Harris luanne.harris@cornerstone-bb.com Luanne Harris One Silverline Drive North Brunswick, NJ 08902 (800) 542-9118 Ext 413596 luanne.harris@cornerstone-bb.com @M Windows ®®®j�' G OO Single Hung Evaluation Report from a Florida Registered Architect or a Li( Florida Professional Engineer Evaluation Report - Hardcopy Received Hermes F. Norero, P.E. PE-73778 Window and Door Manufacturers Association-QA 07/23/2031 Locke Bowden P.E. Validation Checklist - Hardcopy Received FL14911_R12_COI _COI Silverline SS 2017-06-14.pdf Standard AAMA/W DMA/CSA/ 101/I. S.2/A440 1 of 3 2/21/2022, 11:20 AM Florida Building Code Online htips://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGE... Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products AAMA/W DMA/CSA/101/I.S.2/A440 ASTM E1886 ASTM E1996 ASTM E330 TAS 201 TAS 202 TAS 203 Method 1 Option D 10/25/2020 10/25/2020 11/01/2020 12/15/2020 FL # Model, Number or Name Description 14911.1 V1 Series/50 Series (2000) Single -Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911_R12_II_SWD017 SS 2020-10-21_pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 72 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Installation Instructions and Product Evaluation FL14911_R12_AE_PER7259 SS 2020-10-21.pdf Created by Independent Third Party: Yes Report for allowable design pressures, sizes, installation requirements and limits of use. 14911.2 V1 Series/50 Series (2111) Single -Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911_R12_II_SWD018 SS 2020-10-21.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 72 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Installation Instructions and Product Evaluation FL14911_R12_AE_PER7260 SS 2020-10-21.pdf Created by Independent Third Party: Yes Report for allowable design pressures, sizes, installation requirements and limits of use. 14911.3 V1 Series/50 Series (2200/2300) Single -Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911_R12_II_SWD019 SS 2020-10-21.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 72 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Installation Instructions and Product Evaluation FL14911_R12_AE_PER7261 SS 2020-10-21.pdf Created by Independent Third Party: Yes Report for allowable design pressures, sizes, installation requirements and limits of use. 14911.4 V1 Series/70 Series (2127) Single -Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL14911_R12_II._SWD049 SS 2020-10-21.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 72 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Installation Instructions and Product Evaluation FL14911_R12_AE_PER7262 SS 2020-10-21,pdf 2 of 3 2/21/2022, 11:20 AM Florida Building Code Online https://www.floridabuilding.org/pr/pi_app_dti.aspx?param=wGE... Report for allowable design pressures, sizes, installation Created by Independent Third Party: Yes requirements and limits of use. 14911.5 V1 Series/70 Series (2127) Single -Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL14911_R12_II_SWD050 SS 2020-10-23.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 72 Approved for use outside HVHZ: Yes Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Installation Instructions and Product Evaluation FL14911_R12_AE PER7263 SS 2020-10-21.pdf Created by Independent Third Party: Yes Report for allowable design pressures, sizes, installation requirements and limits of use. 14911.6 V1 Series/70 Series (2907/4907) Single -Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911_R12_II_SWD053 SS 2020-10-21.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 72 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Installation Instructions and Product Evaluation FL14911_R12_AE_PER7264 SS 2020-10-21.pdf Created by Independent Third Party: Yes Report for allowable design pressures, sizes, installation requirements and limits of use. Back Next The State of Florida Is an AA/EEO employer. f&ayldght 2007-2013 State of Florida.:: PrNacy Statement :: Accessibilily Statement :: Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email addn one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to s address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Ch please click.bgrp_. Product Approval Accepts: �` Credit Card Safe 3 of 3 2/21/2022, 11:20 AM AMERICAN CRAFTSMAN WINDOWS AMERICAN CRAFTSMAN SILVER LINE WINDOWS AANN NDO F D DOOF SILVER LINE WINDOWS AND DOORS ONE SILVER 41-035IVE NORTH BRUNSWICK, NJ 08902 PH: (88S)741-0354 GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT EDITION FLORIDA BUILDING CODE (FBC), INCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM E330.02 • ASTM E1886-12 • ASTM E1996-17 • AAMA/WDMA/CSA 101/I.S.2/A44D-11 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY, 2X FRAMING, AND METAL FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN NON-HVHZ AREAS. IN HVHZ AREAS, ONE TIME PRODUCT APPROVAL TO BE OBTAINED FROM MIAMI-DADE RER OR AHJ. 5. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6. WINDOW FRAME MATERIAL: PVC 7. IN ACCORDANCE WITH THE CURRENT EDITION FBC, WOOD COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN CHAPTER 23. 8. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 GLASS CHARTS. SEE SHEET 1 FOR GLAZING DETAILS. 70 SERIES / V 1 SERIES / (2127) SINGLE— HUNG WINDOWS (HVHZ) (IMPACT) MAX OVERALL SIZE CONFIG. DESIGN MISSILE WIDTH HEIGHT PRESSURE IMPACTRATING 52" 73" O/X +S5 /-60 PSF LMI/SMI TABLE OF CONTENTS SHEET REVISION SHEET DESCRIPTION 1 - GENERAL NOTES & GLAZING DETAIL 2 - ELEVATION & ANCHOR LAYOUTS 3 - VERTICAL SECTIONS 4 - HORIZONTAL SECTIONS 5 HORIZONTAL & VERTICAL SECTIONS, INSTALLATION NOTES & REINFORCEMENT DETAILS EXTERIOR STEEL SPACER 1/8" OR 3/32" SETT 0 BLOCK 43/64" O.A. I.G. LAMINATED GLASS CONSISTING OF: 1/8" ANNEALED GLASS 7/32"STEELSPACER 0 ANNEALED GLASS 0.09 0.090" SAFLEX PVB INTERLAYER BY EASTMAN CHEMICAL COMPANY 3/32" ANNEALED GLASS GLAZING DETAIL 1 -0 Z In �8m Q �atg_- L9 to > a � � �w- L7 — 3 - m^ WC6 m o ✓t w � ,n z p a a a REMARKS BY F.ATI 7TH FBC EDITION NUS 0/14/ ,n: I am approving this document 2020.10,RhOi1I0Q�i 0 '00' fAjf INTERIOR 'c N. �G ♦♦� i� ttqq N.3� ♦♦ ?SJGDtdi.,'Ys 33. w stow >ce czar. o- auinca�unov � z»+e MIN. GLASS BITE 7/16" J 995 SEALANT TREMCO S700 SEALANT NOTE: A�LAZING CONFIGURATIONS SHALL COMPLY WITH SAFETY GLAZING REQUIREMENTS OUTLINED IN CURRENT FBC AND ASTM E 1300 GLASS LOAD RESISTANCE. FL tt: FL14911 DATE: 01.23.18 DWG. BY: I CHK. BY: HR HFN SCALE: NTS DWG.a: SWD050 SHEET: OF 5 MAX. HEIGH MAX. O.A FRAME HEIGHT 73" MAX. HEIGH MAX. O.A FRAM E WIDTH^1 2 ELEVATION SINGLE HUNG WINDOW 3" MAX. 6" MAX. 6.25" MAX. FROM O.C. FROM CORNERS II CORNERS I 6" MAX. J O.C. 3" MAX. FROM CORNERS I L_ 7— ANCHOR LAYOUT NAIL FIN -SINGLE HUNG WINDOW NOTE: ALL FASTENERS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK MUST BE FLAT HEAD 12.50" MAX. O.C. 6.25" MAX. FROM CORNERS N ANCHOR LAYOUT THROUGH FRAME - SINGLE HUNG WINDOW AERICAN CRAFTSMAN WIN=A VER LINE WINDOWS AND DOOF ONE SILVER LINE DRIVE NORTH BRUNSWICK, NJ 08902 PH: (888) 741-0354 zm ^� 5 s r 5 �Bm Wzu 0 �� w3a u �< --- z C7 v3 ? O N > > m m w W � a C 0 REMARKS BY I DATI 7TH FBC EDITION NUS O/14/ ````.till 1 I I IFl��,'' E N.77 D S A OF '�Bst�i+tnMFtS1.c ' - 398 E B BAM FFL 3 3 a 33B x'a L 33003 FPT Ci3i. 0.' 4VieRN�UT.OV !:o. 2Y.`B FL #: FL14911 DATE: 01.23.18 DWG. BY: I CHK. BY: HR HFN SCALE: NTS DWG. n: SW D050 SHEET: 2 OF 5 x t� x EXTERIOR c z a ;EE GLAZING )ETAIL, SHEET 1 INTERIOR _ SEE GLAZING DETAIL, SHEET 1 q VERTICAL SECTION NAIL FIN SEE GLAZING )ETAIL, SHEET 1 INTERIOR _ SEE GLAZING DETAIL, SHEET 1 VERTICAL SECTION THRU FRAME A ERICAN CRAFTSMAN WINDOU VER LINE WINDOWS AND DOOF ONE SILVER LINE DRIVE NORTH BRUNSWICK, N108902 PH: (888) 741-0354 �3 z� w U p O 3 _Z Loa w w p a — _ > 7 N Q z z_ —=x u w > oa �z m o Ln n w o a a REMARKS I BY I DATI 7TH FBC EDITION NUS O/14/ TND li-iNOT NLi,En 1—C—S FOR A VEai .xon:o\5 a. CRUSL in�,N1A,:ox [o o- nrt xeuuwLmlx,snuAl:Eo nexEm. A "N" F Ex4,x!(4U0. AnCM,ECi SxALI F.VANL Sn[ SVECIFIC ````1�lIIlllrfff,�, o S A _ OF >r :��K��� §d.li+tDtU�t,�nc iiF? GENT. CF AVT4C4SnP.QY Nc. 3?ii8 FL #: FL14911 DATE: 01.23.18 DWG. BY: CHK. BY: HR I HFN SCALE: NTS DWG.#: ;wnnsn I OF 5 SECTION FOR BLOCK&TACKLE _ BALANCERS F 0 nd SEE GLAZING DETAIL SHEET 1 SEE GLAZING `DETAIL SHEET 1 INTERIOR EXTERIOR — D.L.O. MAX. FRAME WIDTH HORIZONTAL SECTION 4 UPPER SASH INTERIOR EXTERIOR D. L.O. MAX. FRAME WIDTH HORIZONTAL SECTION 4 LOWER SASH SEE GLAZING DETAIL SHEET 1 SEE GLAZING DETAIL SHEET 1 SECTION FOR ONSTANTFORCE BALANCERS a can AERICAN CRAFTSMAN WINDON VER LINE WINDOWS AND DOOF ONE SILVER LINE DRIVE NORTH BRUNSWICK, NJ 08902 PH: (888) 741-0354 N D Z o H m wo. z u 0 3 ¢ w �r 7 z N Z Z Vl J ' J = N = � m N Z = m F <0 REMARKS BY I CAT; 7TH FBC EDITION NUS 0/1a/ L11111111""' O N 7 7. D S A OF o O •�i� ASS .. NG� `��� qqD�>zE L ephF.Gfld?t��,c :?fi �. JA�.M14 3EACFt 3r VD. r 33B oa;�a ad.<n 33oa a —=.a.. a w:nca�ura � n�. z5ne FL #: FL14911 DATE: 01.23.18 DWG. BY: CHK. BY: HR I HFN SCALE: NTS DWG. #: SW UUSU SHEET: It OF 5 PERIMETER SEALANT BY OTHERS EXTERIOR LA INTERIOR MIN. SUBSTRATE 1/4" MAX. SHIM SPACE EDGE DISTANCE BY OTHERS INTERIOR MIN. uu EMBEDMENT I 1/4" MAX SHIM SPACE PERIMETER SEALANT BY OTHERS EXTERIOR VERTICAL SECTION 5 THROUGH FRAME (HEAD) 1/4" MAX. SUBSTRATE SHIM SPACE BY OTHERS INTERIOR w w Z EXTERIOR MIN. EDGE DISTANCE HORIZONTAL SECTION 'n'S^•'^T'^"'^'^Tff NAIL FIN (JAMB) EXTERIOR BY OTHERS SCREW IN THE INTERIOR "CHANNEL MIN. EDGE DISTANCE _ SCREW IN THE EXTERIOR CHANNEL MIN. EMBEDMENT HORIZONTAL SECTION S THROUGH FRAME (JAMB) j:) VERTICAL SECTION 5 MEETING STILE wz a � p MIN. EMBEDMENT I SUBSTRATE BY OTHERS — 1/4" MAX. SHIM SPACE EXTERIOR @S INTERIOR HORIZONTAL SECTION 5 NAIL FIN (HEAD) REINFORCEMENT DETAILS INTERIOR -77}7- 09 .45" 0.06" 0 O ALUMIINUMLOCKRAdLTOP O LOCK MEETI ALUM NUMNG RAIL O 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION OF THE MAXIMUM SIZE LISTED. 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF±1/2 INCH THE DEPICTED LOCATION & SPACING IN THE ANCHOR LAYOUT DETAILS (I.E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE 3/81NCH. SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. S. FOR MASONRY OR CONCRETE OPENINGS, 1X WOOD BUCK MAY BE USED (OPTIONAL AS LONG AS THE MINIMUM EMBEDMENTAND EDGE DISTANCE REQUIREMENTS ARE STILL MET WITHIN THE CORRESPONDING HOST SUBSTRATE. SEE GENERAL NOTE H3 ON SHEET 1 FOR MORE INFORMATION. 6. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOTLIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 7. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. 8. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 9. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 10. FOR INSTALLATION ANCHORS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK, USE FLAT HEAD ANCHORS. �j13II--0.13" 0.46" 0.87" BOTTOM LIFT RAIL & SASH ALUMINUM ANCHOR SCHEDULE METHOD SUBSTRATE ANCHOR SCHEDULE MIN EMBEDMENT L11N. EDGE DISTANCE WOOD: MIN SG= 0.55 P8 WOOD SCREW 5' 0.75' PAN HEAD NAILING FIN 3 THREADS MIN ee METAL: 18 GAUGE Stl. MIN. Fy= 33KSI PB 7EK SCREW PENETRATION BEYOND 0.50' METAL P 10 PAN HEAD IN EXTERIOR CHANNEL 1.5' 0.75' WOOD: Mi N. SG = 0.55 P 10 FLAT HEAD IN THE iNTER,.ORCHANNEL 15' 0.]5' P10 PAN HEAD IN 3 THREADS MIN E)(TERIORCHANN'EL PENETRATION BEYOND 0.50' METAL 18 GAUGE SrelL METAL THROUGH FRAME MIN. Fy= 33KSi PiNFLATHEAD iNTH'E 3THREADSEY iMERiOR CHANM�EL PENETRATION BEYaJD 0.50- kETAL CONCRETE: Tr-30DOPS 3118-ITWTAPCON 125' 1.T5- FLAT HELD MU Per iAI 3N6' 2000 PSi F AT EAD FIAT HEAD 1.25' 1.TS ERICAN CRAFTSMAN WINDOW 'ER LINE WINDOWS AND DOOI ONE SILVER LINE DRIVE NORTH BRUNSWICK, NJ 08902 PH: (888) 741-0354 _ Z L.i m �3 o zm nWla- o8m wzu W3aaoo �z� C,z 0 -- ,nz rr o.., N H <� z z - oa w'> w= <�� �m m vt _Z Oz.++ N — � m ^ o u = 0/ a C REMARKS BY I DATI 7TH FBC EDITION NUS 0114/ ,``Y1111i 11111//�', O P01 N.77 y' K v s OF .0 e98 E C.M1'1a S'JdH StVO. a 3?B rsK tear. o: zasre FL N: FL14911 DATE: 01.23.18 DWG. BY: I CHK. BY: HR HFN SCALE: NTS DWG.#: SWD050 SHEET: OF S BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 of American Craftsman Windows 398 East Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@ buildingdrops.com Silver Line Windows and Doors 70 Series / V1 Series / (2127) Single -Hung Windows (HVHZ)(IMPACT) for Florida Product Approval Current Florida Building Code Method: 1— D (Engineering Evaluation) Category: Windows Sub — Category: Single Hung Product: 70 Series / V1 Series / (2127) Single -Hung Windows Material: PVC Product Dimensions: See Installation Instructions, SWD050 Prepared for: Silver Line Windows and Doors One Silverline Dr. North Brunswick, NJ 08902 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date:10/14/2020 Contents: Evaluation Report Pages 1-4 Digitally signed by Hermes F Norero Reason: I am approving this document Date: 2020.10.22 02:28:29 +02'00' Hermes F. Norero, P.E. Florida P.E. No. 73778 BUILDING DROPS ,s A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Manufacturer: Silver Line Windows and Doors Product Category: Windows Product Sub -Category: Single Hung FL#:FL14911 Date: 10/14/20 Report No: 7263 Compliance Method: State Product Approval Method (1)(d) Product Name: 70 Series / V1 Series / (2127) Single -Hung Windows (HVHZ) (IMPACT) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Silver Line Windows and Doors based on Method 1d of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions SWD050, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the Current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the Current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of Installation Instructions SWD050 require further engineering analysis by a licensed engineer or registered architect. S. See Installation Instructions SWD050 for size and design pressure limitations. Hermes F. Norero, P.E. Florida P.E. No. 73778 Page 2 of 4 BUILDING DROPS FL#: FL14911 A Perfect Solution in Every Drop! Date: 10/14/20 Certificate of Authorization: 29578 Report No: 7263 Quality Assurance Entity: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a Quality Assurance Entity through Window and Door Manufacturers Association (FBC Organization #QUA2515). Performance Standards: The product described herein has been evaluated per: Referenced Data: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM E330-02 • ASTM E1886-12 • ASTM E1996-17 • AAMA/WDMA/CSA 101/I.S.2/A440-11 1. Product Testing performed by National Certified Testing Laboratories, Inc. (FBC Organization # TST1589) Report: Dated: NCTL110-16327-1 08/13/2013 Signed and Sealed by: Harold E. Rupp, FL PE No 15935, Sealed Date 02/06/18 NCTL110-16327-2 11/05/2013 NCTL 110-16327-3 08/13/2013 11524.01-109-47 05/01/2018 11238.01-109-47 03/28/2022 2. Quality Assurance Window and Door Manufacturers Association (FBC Organization #: QUA2515) 3. Material Certification Miami -Dade County Notice of Acceptance Eastman Chemical Company (Previously Solutia) Saflex (Vanceva Composites) PVB Interlayer 4. PVC profiles meet requirements of WDMA/HallMark WD-61 in accordance with AAMA 303 Hermes F. Norero, P.E. Florida P.E. No. 73778 Page 3 of 4 Installation: BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 FL#:FL14911 Date: 10/14/20 Report No: 7263 Refer to Installation Instructions (SWD050) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to Installation Instructions (SWD050) for anchor spacing and more details of the installation requirements. Equivalence of Test Standards: Various test standards have been evaluated for differences in test methodology, if any, between tested editions of the test standards listed below and those editions referenced in the current Florida Building Code. Manufacturer has tested their products to the following test standard edition(s): 1) AAMA/WDMA/CSA 101/I.S.2/A440-08 2) ASTM E1886-05 3) ASTM E1996-06/09/12 Chapter 35 of the current Florida Building Code references the following editions of the above mentioned test standards: 1) AAMA/WDMA/CSA 101/I.S.2/A440-11 2) ASTM E1886-12 3) ASTM E1996-17 After review of the above mentioned referenced standards and editions, it has been found that no significant technical changes have been made to the test standards that would affect the results. All referenced standards have been found to be equivalent. All material test results meet minimum requirements of the current FBC including HVHZ provisions. Hermes F. Norero, P.E. Florida P.E. No. 73778 Page 4 of 4