Loading...
HomeMy WebLinkAboutProduct Approval Exterior Door & Panel Walls2/1/2021 Florida Buildin f - 1 n J BCIS Home Log In user Registration Hot Topics j Submit Surcharge d Florida r T `` Product Approval �� g USER: Public User r h"re Product Approval Menu > Product or Aoplication Search > Application list > Applic tT1 Lu'�C�f..' �• FL # F ._3. �` .. s>. Application Type A Code Version 2 Application Status A p Comments Archived Product Manufacturer Address/Phone/Email I Authorized Signature Technical Representative Address/Phone/Email i Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method ' Certification Agency i Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Documentation from approved Evaluation or Validation Entity Online LMN & Facts I Publications Contact Us I BCIS Site Map, I Links Search REVIEWED FOR Detail CODE COMPLIANCE 32-R4 ST. LUCIE COPITY BOCC 3tion � � ZL ✓ed FILE COPY -z Zv -_C,4-o,5-60 T hed, Inc. 1 South Harrison Street S t 600 D er, CO 80210 l 3 474-5567 es@tuffshed.com k Kessler S Harrison Street ar, CO 80210 753-8833 Ext5617 ler@tuffshed.com Doors i Exterior Door Assemblies :ion Mark or Listing and Door Manufacturer Association and Door Manufacturers Association idard Year 4 E330 2014 202 1994 ffirm that there are no changes in the new Florida Building which affect my product(s) and my product(s) are in fiance with the new Florida Building Code. No N/A https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgUYPI UB%2fkWb4jUU9GvGEUFQ%3d%3d 1/3 i S I I Florida Buildi 3 ode Online Product Approval Method at od 1 Option A Date Submitted / 1/2021 Date Validated / 1/2021 Date Pending FBC Approval Date Approved / 6/2021 Summary of Products FL # Model, Number or Name Description 22202.1 Side -hinged Wood Shed Door Side -hinged Wood Shed Door (Outswing - Double Door) (Outswing - Double Door) Maximum Size 80.25" wide by 84" high Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22202 R4 C CAC Tuff456CCL.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 06/14/2028 Design Pressure: +42/-42 Installation Instructions other: Structural only FL22202 R4 II AP-FL-PGEN-03 (Double Door)_pdf Verified By: Window and Door Manufacturer Association ., Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: I 22202.2 Side -hinged Wood Shed Door Side -hinged Wood Shed Door (Outswing - Double Door) HVHZ (Outswing Double Door) HVHZ Maximum Size 80.25" wide by 84" high Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22202 R4 C CAC Tuff456CCL.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 06/14/2028 Design Pressure: +54/-54 Installation Instructions Other: Structural only FL22202 R4 II AP-FL-PGEN-03 (Double Door - HVHZ)_pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 22202.3 Side -hinged Wood Shed Door Side -hinged Wood Shed Door (Outswing - Single Door) (Outswing Single Door) Maximum Size 56" wide by 83.75" high Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22202 R4 C CAC Tuff456CCL.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 06/14/2028 Design Pressure: +42/-42 Installation Instructions Other: Structural only FL22202 R4 II AP-FL-PGEN-02 (SIngle Door pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: I 22202.4 Side -hinged Wood Shed Door Side -hinged Wood Shed Door (Outswing - Single Door) HVHZ (Outswing Single Door) HVHZ Maximum Size 56" wide by 83.75" high Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes F1.22202 R4 C CAC Tuff456CCL.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 06/14/2028 Design Pressure: +54/-54 Other: Structural only Installation Instructions FL22202 R4 II AP-FL-PGEN-02 (SIngle Door - HVHZ)_pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Contact Us :: 2601 Blair Stone Kom The State of Florida is an AA/EEO employer. Copyright 2007-2013 Stal Under Florida law, email addresses are public records. If you do not want you mail to this entity. Instead, contact the office by phone or by traditional mail. II Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 4 provided may be used for official communication with the licensee. However e provide the Department with an email address which can be made available to Product assee FL 32399 Phone: 850-487-1824 ida.:: Privacy Statement :: Accessibility Statement :: Refund Statement address released In response to a public -records request, do not send electronic to any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), must provide the Department with an email address if they have one. The emails resses are public record. If you do not wish to supply a personal address, please IIc. To determine if you are a licensee under Chapter 455, F.S., please click here . al Accepts: cCheck https://www.floridabuilding.orgipr/pr app_dti.aspx?param=wGEVXQwtDquYPIHVa8bc0"UX3gCszgVbgJZB%2bUB%2fkWb4jUU9GvGEUFQ%3d%3d 2/3 ,SSEMBLY INSTRUCTIONS:. OTE: INSTRUCTION #1 THROUGH 94 ARE TO BE ERFORMED IN FACTORY. INSTRUCTION #51S TO BE ERFORMED ON JOB SITE. ATTACH ITEM 1 (7/16" ENGINEERED WOOD SHEATHING) TO ITEM 2 (STEEL DOOR FRAME-1-1/2° CHANNEL) WITH 3 ITEM 3 (#8 x 1-1/2" SCREWS) @ 6" O.C. AND (2) SCREWS AT EACH END OF EVERY STEEL CHANNEL AS SHOWN IN DETAIL'B'. i- ATTACH ITEM 4 (3/8° SMARTSIDE EXTERIOR 6 / ' ENGINEERED WOOD SHEATHING) TO ITEM 2 (STEEL DOOR FRAME-1-1/2" CHANNEL) WITH ITEM 3 (#8 x 1-112 SCREWS) @ 6" O.C. AND (2) SCREWS AT EACH END OF ' EVERY STEEL CHANNEL AS SHOWN IN DETAIL'B'. ATTACH ITEM 5 (DOOR TRIM) TO ITEM 4 (3/8" SMARTSIDE EXTERIOR ENGINEERED WOOD SHEATHING) WITH EXTERIOR GRADE CONSTRUCTION B ADHESIVE AND ITEM 6 (NAILS) @ 6" O.C. AND (2) NAILS; AT EACH END OF EVERY TRIM PIECE AS SHOWN. SEE DETAIL'N - FOR INSIDE VIEW OF AS A HINGE. ,. INSTALL OUTSIDE HANDLE (COMPONENT OF ITEM #7) TO THE DOOR ASSEMBLY WITH (2) ITEM 8 (#8 x 2-1/4 '1. L SQUARE DRIVE SCREWS). INSTALL CAB LATCH (COMPONENT OF ITEM #7) TO THE DOOR ASSEMBLY ' WITH (4) #8 x 2-1/4 SQUARE DRIVE SCREWS. ATTACH 5 INSIDE HANDLE (COMPONENT OF ITEM #7) AND SECURE WITH WASHER AND NYLOC ON HANDLE SHAFT (COMPONENTS OF ITEM #7). SEE DETAIL W. 9 PARTIAL INSIDE VIEW PARTIAL END VIEW PARTIAL OUTSIDE VIEW 02 HANDLE DETAIL TUFF SHED Storage Buildings & Garages TUFF SHED, INC. ma:Scale: Order#. Customer. Site Address: PO# Drawn By: PK Dale: 5/24/18 Checked By: Date: Building Size:•.., - ENG H-ME HT-sRF,.A°fA N.T.S. =a DETAIL'B' La ASSEM THESE DRAWINGS AND THE DESIGN ARE THE PROPERTY OF TUFF SHED, INC. THESE DRAWINGS ARE FOR A BUILDING TO BE SUPPLIED AND BUILT BY TUFF SHED. ANY OTHER USE IS FORBIDDEN BY TUFF SHED INC 8 THE ENGINEER OF RECORD. 1 — 7/16" APA ENGINEERED WOOD SHEATHING "APA APPROVED° 2 — ISTEEL DOOR FRAME: 1-1/2" STEEL DOOR FRAME QUAIL RUN 3 — 1#8 x 1 1/2" WOOD SCREW SOUTHERN CARLSON 4 — 3/8° SMARTSIDE ENGINEERED WOOD SIDING LOUISIANA PACIFIC 5 — IDOOR TRIM LOUISIANA PACIFIC 6 — I NAIL SOUTHERN CARLSON 7 390209 ITUFF SHED "L" HANDLE ASSEMBLY SIERRA PACIFIC 8 — #8 x 2-1/4" SQUARE DRIVE WOOD SCREW GMS 9 HTH6099 STUFF SHED HINGE i SIERRA PACIFIC 1 ---,— -� DOOR HANDLE AND STRIKE PLATE ATTACHMENT SIERRA PACIFIC PART #390209 O SINGLE DOOR ASSEMBLY STRIKE PLATE WITH 3 OP VIEW DRIVE WOOD SCRM LOCATED AS SHOW INSIDE / HANDLE CABLATCH NYLOC #8 x 2-1/4" SQUARE WASHER DRIVE SCREWS DETAIL'A' A 3 TUFF SHED HINGES DOOR. ATTACH EACH HINGE WITH (7) #8 x2-1/4" SQUARE DRIVE WOOD SCREWS, HINGES TO BE LOCATED AS SHOWN. ®HINGE ASSEMBLY DETAIL :FRONT VIEW DRAWINGS BY: TITLE DRAWING NO. TUFF SHED, INC. AP-FL-PGEN-02 4- (4067) DOOR ASSEMBLY IN HOUSE DRAFTING DEPARTKENT AND INSTALLATION REV. LEVEL 01 {,��,�,,L Report B: 15502.02-450-18 1777 S. HARRISON STREET' ;�ii�f�kDate: 08/14/18 DENVER,COLORAD080210 SHEET VulOed by: ^� _ 1./?.-4 (303) 753-TUFF TUFF SHED INC. ASSUMES ALL RESPONSIBILITY FOR THE CONTENT OF THESE DRAWNGSAND THE SHEET 1 OF 3 ITEM IPART NUMBER DESCRIPTIONff] VENDOR 48 112 OPENING 10 P47 4067 TUFF SHED DOOR TUFF SHED 1/4 11 — STEEL BASE QUAIL RUN 12 — STRUCTURAL WALL PANEL ASSEMBLY TUFF SHED 13 — 3/4" APA FLOOR DECKING "APA APPROVED" 14 — DOOR TRIM - VERTICAL LOUISIANA PACIFIC 1/4 15 15 — DOOR TRIM -HORIZONTAL LOUISIANA PACIFIC 16 — STRIKE PLATE SIERRA PACIFIC 36 11/16 17 — NOT USED — 18 -- TRIMMER STUD MARKET LUMBER 12 19 — 98 x 2-1/4" SQUARE DRIVE WOOD SCREW GMS 79 OOR STRIKE DOUBLE TOP PLATE OPTIONAL HEIGHT PLATETR i CONFIGURATION 39 1/2 3611116 r 18 ��\\ HEADER I !!11>Al DOUBLE TOP PLATE 48 DOOR OPARTIAL FRONT VIEW 31116 suacvr-ra NSTALLATION INSTRUCTIONS: ATTACH COMPLETE DOOR ASSEMBLY WITH HINGES TO WALL PANEL ASSEMBLY WITH ITEM 19 (#8 X 2-1/4" SO DRIVE WOOD SCREWS) AT LOCATIONS SHOWN. (4) SCREWS PER HINGE. ?. ATTACH ITEM 16 (STRIKE PLATE) TO ITEM 18 (TRIMMER STUD) WITH (2) ITEM 19 (#8 X 2-1/4" SO DRIVE WOOD SCREWS) AT LOCATION SHOWN. CRIPPLES HEADER ©PARTIAL DED ASS ® INSIDE VIEW EMBLY O OURTSIDE VIEWBLY OUTSIDE VIEW scue r• vm sum. +a . i ar sruF. gym. i ff Order #. PO # THESE DRAWINGS AND THE DRAWINGS BY: TUFF SHED, INC. TITLE DRAWING NO. TUFF SHED Customer. Drawn By: PK DESIGN ARE THE PROPERTY OF TUFF SHED, INC. THESE 4' (4067) DOOR ASSEMBLY AP-FL-PGEN-02 itorage Buildings & Garages Site Address: Date: 5/24/18 DRAWINGS ARE FORA BUILDING TO BE SUPPLIED t IN HOUSE DRAFTING DEPARTMENT 1777 S. HARRISON STREET AND INSTALLATION REV. LEVEL 01 TUFF SHED, INC. Checked By: Y AND BUILT BY TUFF SHED. ANY OTHER USE IS l-_ k ( .1.. ea-k aevori n: Date: 15502.02-450-I8 + oa/14/1s DENVER, COLORADO 80210 SHEET L Date: FORBIDDEN BY TUFF SHED ENGINEER OF 1�hi2 FL—°""y"" Veriaedby: Q? C (303) 753-TUFF Building Size:,,o H- sRc H• ucH -SIFT. INC &THE RECORD. TUFF SHED IN ASSUNESA RESPONSIBILITY FOR OFT�BE�INGSSSHSOW D SHEET 2 OF 3 Scale: N.T.S. CONSTRUCTION OF EAR IN (2 9/16) (6 5/16) Oo ' 00 o O^ OTUFF SHED HINGE VENDOR: SIERRA PACIFIC Spa'•''"• PART#HTH6099 5 3 15 16 DOOR TRIM VENDOR: LOUISIANA PACIFIC SCRIE T•PP (5 518) G OTUFF SHED "L" HANDLE_ VENDOR: SIERRA PACIFIC PART #390209 VARIES BASED ON DOOR WIDTH C 10 7/16" APA ENGINEERED WOOD PANEL VENDOR: "APA APPROVED" swE: r • ra 7(1 1/2) N 17 STRIKE PLATE_ VENDOR: SIERRA PACIFIC S- -- I I m lu I STEEL DOOR CHANNEL_ VENDOR: QUAIL RUN scue r•ra I ,T M 7/16" OSB SPACER 13 2 X LUMBER HEADER_ VENDOR: TUFF SHED Sw -r•rm — VARIES BASED ON DOOR WIDTH M ®3/8" SMARTSIDE PANEL SIDING VENDOR: LOUISIANA PACIFIC a"''� FL APPROVAL #9190.6 13 Q TOP & BOTTOM PLATES, STUDS VENDOR: MARKET LUMBER SME:— MINIMUM 2X4 SPF#2 I' U F F SHED Itorage Buildings & Garages TUFF SHED, INC. Order #. Customer. Site Address: PO # THESE DRAWINGS AND THE DESIGN ARE THE PROPERTY OF TUFF SHED. INC. THESE DRAWINGS ARE FOR A BUILDING TO BE SUPPLIED AND BUILT BY TUFF SHED. ANY OTHER USE IS FORBIDDEN BY TUFF SHED INCBTHE ENGINEEROF �k Report R: 15502.02 450.18 Date: 08/14/18 �..,.�.. • Verified h _ Y®=.•.l•I== �"�- DRAWINGS BY: TUFF SHED, INC. TITLE 4' (4068) DOOR ASSEMBLY AND INSTALLATION COMPONENT DETAILS DRAWING E AP-FL-PGN 02 Drawn By: PKO. IN HOUSE DRAFTING DEPARTMENT 1777 S. HARRISON STREET DENVER, COLORADO 80210 303 753-TUFF NFFSHEDINC.ASSUMES ALL RESPONSIBILI7YFOR THE CONTENTOFTHESE DRAWINGSPNOTHE CONSTRUCTION OF THE BUILDINGS SHO HEREX Date: 5/23/18 REV. LEVEL 01 Checked B y SHEET �] J Dte: a BUlldingSlZe:wmTH-tFN"iH-nDcxr-saFr.ara<w Scale: N.T.S. RECORD. SHEET 3 OF 3 ;_!,'i/2021 Florida Bu Online BCIS Home i Log In ; User Registration I HotTopics Submit Surcharge Product Approval M USER: Public User Product AD.proval Menu > Product or Aopllcation Search > Agplication List > Appli FL # FL9190 Application Type Revisio Code Version 2020 Application Status Approv Comments Archived Product Manufacturer LP Buil Address/Phone/Email 414 Ur Suite 2 Nashvi (352) , cw.ma, Authorized Signature CW Ma cw.ma Technical Representative CW Ma Address/Phone/Email 5712 E Ocalo, (352). cw.ma Quality Assurance Representative CW ME Address/Phone/Email 5712 ! Ocala, (352) cw.ma Category Panel Subcategory Siding Compliance Method Evalua ac» 1j & Fads { Publications 1 Contact Us BCIS Site Map j Links Search REVIEWED FOR CODE COMPLIANCE Detail ST. LUCIE COUNTY B®CC 7, z, e2 7 ./ FILE C®py Solutions Street - Bank of America Plaza 'N 37219 7457 Ier@lpcorp.com ber )er@Ipcorp.com ber Oth Place 4474 7457 per@ipcorp.com ber Oth Place 14474 7457 ber@lpcorp.com Report from a Florida Registered Architect or a Licensed Florida it Engineer :ion Report - Hardcopy Received Florida Engineer or Architect Name who developed the Do Kin P E. Evaluation Report Florida License PE-49 7 Quality Assurance Entity APA - Engineered Wood Association Quality Assurance Contract Expiration Date 12/31 030 Validated By James .�uckner, P.E. @ CBUCK Engineering V d lion Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1405 1604 LM%2fVA7w4rISE%2bkuUjl%2bUgYQ%3d LP SmartSide@ TRIM & SIDING GENERAL • At the time of manufacture, siding meets or exceeds the performance standards set forth in ICC-ES AC321 and has achieved code recognition under ESR-1301, CCMC 11826-L. APA recognition under PR-N124, and HUD recognition under HUD-MR-1318c. For copies of Product Approvals go online at https:/Ilpcorp.com/resources/product-literature/ or call LP Customer Support at 800-648-6893. • Minimum 6 inch (152 mm) clearance must be maintained between siding and finish grade (ground cover). • Siding applied adjacent to porches, patios, walks, etc. must have a clearance of at least 1 inch (2S mm) above any surface. • Minimum 1 inch (25 mm) clearance at intersection with roof line. • Apply siding in a manner that prevents moisture intrusion and water buildup. • All wood substrate that is exposed to the weather must be sealed in a mannerthat prevents moisture intrusion and water build up. - Seal ALL exposed cuts of siding and trim. Field spray applied coatings on cuts are not recommended. - Sealing can be accomplished by applying a coating or sealant according to the manufacturer's requirements. - Butt joints that are covered with joint molding, sealant orfactoryprefinished end, are considered sealed from the weather. • See Alternate Fastening Options for fastening lap siding to SIP, ICF and Steel Frame assemblies. • DO NOT USE STAPLES. SIDING MUST NOT BE IN DIRECT CONTACT WITH MASONRY, CONCRETE, BRICK, 5TONE, STUCCO OR MORTAR. STORAGE • Store off the ground well supported, on a flat surface, under a roof or separate waterproof covering. • Keep siding clean and dry. Inspect prior to application. STUD SPACING • 38 Series Strand Substrate lap may be installed on studs spaced a maximum of 16 inches (406 mm) o.c. • See Alternate Fastening Options for fastening 38 Series Strand Substrate 6 inch (1S2 mm) and 8 inch (203 mm) lap on studs spaced a maximum of 24 inches (610 mm) mc. • 76 Series Strand Substrate lap may be installed on studs spaced a maximum of 24 inches (610 mm) o.c. 38 AND 76 SERIES STRAND SUBSTRATE SMOOTH FINISH OR CEDAR TEXTURE PRIMED LAP SIDING :or installations over masonry or concrete walls, the wall hall be furred out and open at the top and bottom of the wall o allow for convective ventilation between framing spaced 6 inches (406 mm) o.c. The framing shall be of adequate hickness to accept 1-1/2 inches (38 mm) of nail penetration. A iroperly installed breathable water-resistant barrier is required letween the siding and masonry or concrete walls. oisture control and moisture vapor control are critical ements of proper housing design. Check your local building ides for application procedures for handling moisture and ater vapor in your area. Then using wet blown cellulose insulation, the insulation ust not be in direct contact with the'siding and it must be lowed to dry a minimum of 24 hours or longer if specified by ie insulation manufacturer. s with all wood products, do not.appry engineered wood ding to a structure having excessive moisture conditions such drying concrete, plaster or wet blown cellulose insulation. If ich conditions exist, the building should be well ventilated to low it to dry prior to the application of the'siding. ding must not be applied to green or crooked structural aming members. Do not apply siding over rain -soaked or ickled sheathing materials. are recommended for control of roof water run off, properly installed water-resistant barrier is required behind ling. Consult your local building code for details. LP SmartSide limited warranty does not expressly or licitly cover water penetration. LP does not assume onsibility for any water penetration. all gaps with a high -quality, non -hardening, paintable ant meeting ASTM C920, minimum Class 2S. low the sealant manufacturer's instructions for application. openings must be properly sealed or flashed in a manner that events moisture intrusion or buildup, Several examples that :omplish this are shown on the following pages. Application instructions tc®nt.) All openings must be properly sealed or flashed in a manr,�r that prevents moisture intrusion or buildup. Several examples that accomplish this are shown on the following pages. • Install kick -out flashing to direct the water into the gutter • Install step flashing with minimum 4 inch upper leg • Properly integrate flashing with the secondary water -resistive barrier. Use housewrap, flashing tape, Z-flashing, or other items as needed to maintain the counterflashing principle. • DO NOT extend the siding ortrim into the kick -out flashing or gutter • Maintain a clearance between the end -of the gutter and the adjoining wall to allow for proper maintenance of the siding • Prime and paint ALL exposed cut edges Min.1" clearance between trim and roofing Clean rain gutter Do not run trim or siding inside the Icicic out flashing Trim should be thick enough so the siding does not extend beyond the face of the trim. • Trim and fascia must be applied in a manner that will not allow moisture intrusion or water buildup. • LPG SmartSide° siding is not designed and/or manufactured to be used as trim or fascia. LP SmartSide trim and fascia are available in a variety of dimensions. FINISHING INSTRUCTIONS • Prime and paint all exposed surfaces including all drip edges or where water will hang. finish coat as soon"as possible or within 180 days plication. quality acrylic latex paint, specially formulated for use on and engineered wood substrates, is highly recommended. -gloss or satin finish oil or alkyd paints are acceptable. For Ikyd paint, please check with the coating manufacturer for recommendations for use on composite wood siding. • F II¢w the coating manufacturer's application and i tenance instructions. DO 0USE -based paint (like vinyl acetate, or PVA). HA E PREFINISHED LP SMARTSIDE PRODUCTS WITH E ME CARE DURING STORAGE AND APPLICATION. TOUCH UP NII DAMAGE TO THE FINISH THAT MAY OCCUR DURING AP ICATION PER PREFINISHERS SPECIFICATIONS. • I r braced wall assemblies, use minimum (0.113 inch shank d meter) hot -dipped galvanized nails for 38 and 76 Series p n Is and minimum (0.131 inch shank diameter) for 190 Series p nls. Do not use electroplated fasteners. Refer to your local b it ing code to verify the minimum allowable fastener size. •P nitrate structural framing or wood structural panels and s uctural framing a minimum of 1-1/2 inches. •F r 8 Series panels, double nailing procedure meets wall acing requirements and 5/16 inch shear wall design values. 1" from edge bead gap Double row of nails and 190 Series panels, single nailing meets wall brac- uirements. To meet the equivalent 3/8 inch shear wall values, double nailing procedures must be used. It may essary to angle drive the second nail in order to penetrate ming. Seal nails driven below the surface. Alignment bead . 1-1/2" 3/8"from edge 1/8" gap Single row of nails e Application instructions Ontej y CON I rION CORRECTION • Shear values for panels applied directly to studs shall be no Snu Ch OK greater than noted in Table 1 of the ICC-ES Report ESR-1301 or NU kzT l Table 1 of APA PR-N124. Flu ® OK • Not warranted for application on ICF assemblies. • 38 and 76 Series panels must be installed on 16 inch o.c. framing Visi le fiber ® Paint ®' only. When installing on 24 inch o.c. framing,190 Series panels are required. Cou te sunk ® Apply sealant • Backside of panel must not come in contact with masonry or Cou t rsunk more ® Apply sealant and —� concrete foundation. tha t 8" re -nail • Do not force siding into place. Maintain the illustrated 1/8 inch gap behind the joint to allow for expansion while the panel i equilibrates with the local environment. 1 N. ROOF Fx CHIMNEV CLEARANCE • ❑O NOT INSTALL OVER ALIGNMENT BEAD. Install panels in light contact to the edge of alignment bead. (see Figure 1 and Figure 2) k N� -� i • Climb cut the surface of the siding such that the rotation of the blade cuts downward on the primed or prefinished surface. • Where siding butts window trim, door casings and masonry, etc. leave a 3/16 inch gap and seal. Trim jInsulated Sheathings LP SmartSide Sidings may be installed over low -compression rigid i foam or exterior gypsum. The following precautions must be followed; a) Adequate bracing of the wall in accordance with the International 4" 116. vertical • Prime and pair 'lashing bottom drip Codes or other ruling building code is required. edges 1 1' min. b) For rigid foam sheathing up to 1 inch (25 mm) thick, siding clearance from may be nailed directly to the foam sheathing unless a drainage roofing plane is required by the local building code. Nail length must be increased to ensure a minimum 1-1/2 inch (38 mm) fastener I penetration into the structural framing. Figure c) For rigid foam sheathing greater than 1 inch (25 mm), a minmum ' 1-1/2 inch (38 mm) thick by 3-1/2 inch (89 mm) wide vertical 1' strapping or furring strip must be installed over the sheathing to SMARTSIDE PANEL provide a solid, level nailing base for the siding. The strapping must be securely fastened to structural framing spaced no greater than HORIZONTAL WALL JOINTS 16 inches o.c. (406 mm) with a minimum nail penetration of 1-1/2 inches (38 mm) and a maximum nail spacing no greater than the BUTT R FLASH LAP width of the siding. p: Siding Louisiana-Pacific Corporation will assume no responsibility for any damage or condition arising from the use of rigid foam or exterior 3/8' rn P °; Siding Blocking Blocking gypsum. 4 ' 1" min. I c overlap I Sloped Lap p panel r = , flashing with over bottom i i s 12" max. 4" vertical leg panel r field nailing Figure 5A Figure 56 .YYJ' i t %W�tl E 1 Yv? 6' max. LAPPED HORIZONTAL WALL JOINT perimeter 6" max. , nailing perimeter Siding nailing nailing '' 6" min. groundFraming (band joist, Do not let panel clearance truss chord, etc.) contact masonry (see Figure 7A and 7B) 1" min / Wall Framing Figure 3 overlap Figure 5C I ' APPLICATION INSTRUCTIONS (CONY.) sheathing to provide a solid level nailing base for the siding. The strapping must be securely fastened to structural framing spaced no greater than 16 inches (406 mm) o.c. with a mini- Figu mum nail penetration of 1-1/2 inches (38 mm) and a maximum nail spacing no greater than the width of the siding. luisiana-Pacific will assume no responsibility for any damage or ndition arising from the use of rigid foam insulation sheathing exterior gypsum. re 1 Space nail min. 3/4" from top R� Breathable Sheathing, water-resistant Min. 1" if required barrier overlap „ q� Siding must not Extend siding ;'x contact masonry below plate finish grade clearance %z' BUTT JOINTS Figure 2 Nail min. 3/4" from top and 3/8" from edge Butt joints must occur over studs. • A minimum 3/16 inch (5 mm) gap is required at ALL butt joints. •. If joint caulking option is selected, seal all gaps at butt joints with a high -quality exterior sealant meeting the ASTM C920, minimum Class 25 sealant. • If joint moulding option is selected, add the thickness of the web to the gap allowing a net 3/16 inch (S mm) space for expansion. If siding is prefinished, gap does not require sealant or joint moulding when backed with minimum 4 inch (102 mm) wide flashing and the ends of the siding are factory finished. 4'jjjlrijn. flashing Trim Min. 3/16" gap Paint bottom edge of siding 1" min, clearance from roofing LP S I ar d Substrate Lap Siding may also be installed in compliance with Cate 8140- Exterior wall siding and sheathing for Wildland Unban Inter cg (WUI) applications atop LP FlameBlocl<sheathing. Referto Flarr Ell ck installation instructions and product data sheets. All LP lap sidi may be installed as exterior siding in Wildland Urban Interface (WU applications installed over one layer 5/8" (16 mm) Type X gypsum she ing applied behind the exterior covering or cladding on the exterior side tie framing. They may also be installed over the exterior portion of a h urfire-resistive exteriorwall assembly designed for exteriorfire exp r including assemblies using the gypsum panel and sheathing prod t, listed in the Gypsum Association Fire Resistance Design Manual. The u siana-Pacific Corporation ("LP") LP SmartSide Siding (the "Pro s") limited warranty (the "Warranty") applies onlyto structures on whic t e Products have been applied, finished and maintained in accordance with published application, finishing and maintenance instructions in of c atthe time of application. The failure to follow such application, finis n or maintenance instructions will void the Warranty as to the portion of P�oducts affected by the variance (the "Affected Products"). LP a Prol loss Any regr For sup W, orf W/ RE nes no liability for any loss or damage sustained by the Affected and is expressly released by the purchaser or owner from any such ability. lification of the Warranty's application, finishing or maintenance cents is void unless approved in writing by LP priorto application. )pv of the warranty or for installation and technical , visit the LP SmartSide product support Web site at: .Ipsmartside.c®m itional support call 800-648-6893. NTY REMEDIES ARE NOT AVAILABLE IF EMENTS ARE NOT FOLLOWED. d dRMING: Drilling, sawing, sanding or machining wood pr u is can expose you to wood dust, a substance known to the st i if California to cause cancer. Avoid inhaling wood dust or us c ust mask or other safeguards for personal protection. For mo i riformation go to www.PSSWarnings.ca.gov/wood. SmartSide° TRIM & SIDING rL cific Corporation. All rights reserved. LP and SmartSide are registered trademarks oCorporation. Printed in U.S.A. Ncific Corporation periodically updates and revises its product information. Tersion is current, call 800-648-6893. 4 6' 6 in. Figure 19 1y. �L [�C,9�aRa• N �. "P i�.i •F [ e P-WhA bottom course detail Figure 10E alt = Mate insi de cornew details. _ Gap 3/16" and seal Gap 3/1 nd seal - -- -- ahlplap Edge Fig Vapor Retarder tf regw red by code Figure 10B Water -Resistive Barrier dy : e [�6 in. minimum ground a'lt 1 nce Figure 10C LPZBOS12 04/09/2020 SmartSide @ TRIM & SIDING At the time of manufacture, siding meets or exceeds the performance standards set forth in [CC -ES AC321 and has achieved code recognition under ESR-1301, CCMC 11826-L, APA recognition under PR-N124, and HUD recognition under HUD -MR# 1318c. For copies of Product Approvals go online at https://Ipcorp.com/resources/product-literature/ or call LP Customer Support at 800-648-6893. Strand Substrate panel siding with SilverTech or SmartFinish is specifically for sheds and other outdoor structures where the interior wall cavities will remain permanently exposed. • Minimum 6 inch clearance must be maintained between siding and finish grade (ground cover). • Siding applied adjacent to porches, patios, walks, etc. must have a clearance of at least 1 inch above any surface. • Minimum 1 inch clearance at intersection with roof line • Apply siding in a manner that prevents moisture intrusion and water buildup. • All wood substrate that is exposed to the weather must be sealed in a manner that prevents moisture intrusion and water build up. - Seal ALL exposed cuts of siding and trim. Field spray applied coatings on cuts are not recommended: - Sealing can be accomplished by applying a coating or sealant accordingto the manufacturer's requirements. • All exposed wood substrate must be sealed in a manner that prevents moisture intrusion and water buildup. • LP does not recommend LP SmartSide Panel for use in ICF assemblies. if used, LP will not warrant for Buckling and Shrinkage. However, balance of warranty does remain intact. • Use nails to fasten LP SmartSide panel siding to structural framing. The use of alternate fasteners such as staples is permissible only when allowed by [-Codes and where the size, embedment, placement, and number of alternate fasteners is designed by a licensed design professional and approved by local building official. The use of alternate fasteners, however, is not recommended and LP will not warrant any damage or performance failures to the extent caused by using any alternate fasteners. • SIDING MUST NOT BE INDIRECT CONTACT WITH MASONRY, CONCRETE, BRICK, STONE, STUCCO OR MORTAR. • Store off the ground well supported, on a flat surface, under a roof or separate waterproof covering Keep siding clean and dry. Inspect prior to application. STRAND SUBSTRATE 38,76 AND 190 SERIES PRIMED PANEL SIDING INCLUDING SILVERTECH Fr SMARTFINISH nd Substrate 38 and 76 Series panel siding must be ailed with the long dimension vertially on studs spaced % 16 inch o.c. When installing on 24,inch o.c. framing, Series panel siding is required. • turcontrol and water vapor control are critical elements poper housing design. Check your local building codes for p,cation procedures for handling moisture and water vapor 11oie v ur area. • ; en using wet blown cellulose insulation, the insulation ust not be in direct contact with the siding and it must be II o wed to dry a minimum of 24 hours or longer if specified by 16 insulation manufacturer, •i vith all wood products, do not apply engineered wood i g to a structure having excessive moisture conditions such tying concrete, plaster or wet blown cellulose insulation. If e i conditions exist, the building should be well ventilated to 110,w it to dry prior to the application of the siding. • ding must not be applied to green or crooked structural ing members. Do not apply siding over rain -soaked or IaTI(led sheathing materials. • Nul)ters are recommended for control of roof water run off, • trongly recommends the use of a secondary water -resistive r ler behind all LP SmartSide siding. A properly installed B provides a second line of defense to incidental moisture hind the siding. • E LP SmartSide limited warranty does not expressly or licitly cover water penetration. LP does not assume s onsibility for any water penetration. • ds and other accessory structures that are not heated or died do not require a secondary WRB if exempt by applicable i ding codes. • e' I all gaps with a high -quality, non -hardening, paintable ejlant. Follow the sealant manufacturer's instructions for o lication. lsa an exterior -quality, non -hardening, paintable sealant. Use lass 2S or higher exterior sealant meeting the ASTM C920 t�ndard for Specification for Elastomeric joint Sealants. o low the sealant manufacturer's instructions for application. APPLICATION INSTRULTIONS 4LUN I .] Klc"K-OUT FLASHING • Install Kick -out flashing to direct the water into the gutter. • Install step flashing with minimum 4 inch (102 mm) upper leg. • Properly integrate flashing with the secondary water-resistant barrier. Use housewrap, flashing tape, Z-flashing, or other items as needed to maintain the counterflashing principle. • DO NOT extend the siding or trim into the kick -out flashing or gutter. • Maintain a clearance between the end of the gutter and the adjoining wall to allow for proper maintenance of the siding. • Seal ALL exposed cut edges. / \ LP Siding \ Min.1" clearance 1 /) between siding and roofing Clean rain gutter Do not run siding or trim inside of the kick out flashing • Trim should be thick enough so the lap siding does not extend beyond the face of the trim. • Trim and fascia must be applied in a manner that will not allow moisture intrusion or water buildup. • LP° SmartSide° siding is not designed and/or manufactured to be used as trim. - LP SmartSide trim and fascia are available in a variety of dimensions. • Seal all exposed surfaces, including all drip edges or where water will hang. • Apply finish coat as soon as possible or within 180 days of application. • Follow the coating manufacturer's application and maintence instructions. o best results use a high -quality 100% acrylic latex exterior a nt, specially formulated for use on wood and engineered `od substrates is highly recommended; oil paint is acceptable. OT USE: t aln. • i yl-based paint (vinyl acetate or PVA). S 0 3TH FINISH Lap Siding: o,r best results use satin finish. C rr RTEXTURE Lap Siding: best results use satin or semi -gloss finish. P E WISHED Lap Siding: • ndle prefinished LP SmartSide lap siding with extreme care it ring storage and application. • rc ch up any damage to finish that may occur during plication per the Prefinishers specifications. • IP SmartSide 38 Series lap siding may be attached directly to ra ing members spaced a maximum of 16 inches (406 mm) o.c. • P SmartSide 76 Series lap siding may be attached directly to ra ing members spaced a maximum of 24 inches (610 mm) o.c. • li ack your local building codes before starting to install siding o; onfirm if wood structural panel wall sheathing is required. u t joints should be staggered over successive courses. • i ing shall be installed with top (blind) nailing, with the nails laced 3/8 inch (10 mm) from either end and a minimum of /4 inch (19 mm) from the top edge of the board. Fasteners will e exposed on siding located immediately below window sills, a cia boards, and horizontal trim. Fasteners below window sill h' II be spaced a maximum of 8 inch (203 mm) o.c. • v Hap successive courses of siding a minimum of 1 inch (2S mm). s a minimum (0.113 inch shank diameter), hot -dip galvanized Self-ali rabbet ap SrnartLock Lap Blind Fastening 3/4" nail spacing Install SmartLock Lap consistent with specifications in this document APPLICATION INSTRUCTIONS kLONToj tly I 'CONDITION CORRECTION ug ® OK y ish OK Bible fiber ® Paint untersunk 1/16"-1/8"_ ® Apply sealant untersunk more ® Apply sealant and — re -nail an 1/8" All exposed face nails must be caulked and sealed in a manner that prevents moisture intrusion and water buildup. Penetrate structural framing or wood structural panels and structural framing a minimum of 1-1/2 inches (38 mm). Nail from the center of the siding toward the ends, or from one end to the other end. NEVER nail from the ends of the siding toward the middle. Shim siding at studs as needed, to avoid drawing siding against uneven walls. Do not overdrive nails. Nail head should seat firmly to face of siding but not be overdriven to distort the siding surface. • For information on fastening LP SmartSide products in high wind speed areas, refer to ICC-ES Report ESR-1301 or APA PR-N124. Alternative Fastening Option for Strand Lap Siding over Wood Structural Panels and 24 inch (610 mm) o.c. Stud Spacing ;• Limited to 6 inch (1S2 mm) and 8 inch (203 mm) wide lap siding. l; • Wood structural panels must be a minimum 7/16 Category with an APA Trademark that contains the consensus Standard DOC PS 2. k• 38 Series Strand Substate lap must be fastened with: Yt - Minimum #8 hot dip galvanized tapered head wood screw, spaced a maximum of 12 inches (305 mm) o.c. with 1-1/2 inch (38 mm) screw penetration into stud or... - Minimum (0.092 in. shank diameter) hot -dip galvanized ring shank nail, spaced a maximum of 8 inches (203 mm) o.c. with 1-1/2 inch (38 mm) nail penetration into stud. 4' Alternative Fastening Options over SIP Assemblies 4 • Wood structural panels must be a minimum 7/16 Category with an APA Trademark that contains the consensus standard DOC PS 2. = 38 Series Strand Substrate lap must be fastened with: - Minimum #8 hot dip galvanized tapered head wood screw, spaced a maximum of 12 inches (30S mm) o.c. or... - Minimum (0.092 inch shank diameter) hot -dip galvanized ring shank nail, spaced a maximum of 8 inches (203 mm) O.C. • 76 Series Strand Substrate lap must be fastened with: - Minimum #8 hot dip galvanized tapered head wood screw, spaced a maximum of 16 inches (406 mm) o.c. or... - Minimum (0.092 inch shank diameter) hot -dip galvanized ring shank nail, spaced a maximum of 12 inches (305 mm) o.c. Alternative Fastening Option over ICF Assemblies • 38 and 76 Series Strand Substrate Lap must be fastened with: inimum #8 hot -dipped galvanized, tapered head, If -drilling screw. inimum penetration of 3/8 inch (10 mm) beyond the ickness of the nailing flange. 3rger screws may be required by the ICF Manufacturer ised on the following minimum withdrawal requirements. • MI i 411 um withdrawal value of the ICF nailing flange must be SO bs. with a maximum 12 inches (305 mm) o.c, screw spacing. • Mi ' um withdrawal value of the ICF nailing flange must be 31 sl. with a maximum 6 inches (1S2 mm) o.c. screw spacing. Fastening Options over Corrosion Resistant Framing MITum withdrawal value of the steel framing must be 50 lbs. • o the framing manufacturer's evaluation report. • 3E eries Strand Substrate lap must be fastened with: Stud spacing a maximum spacing of 16 inches (406 mm) o.c. Minimum #8 hot -dip galvanized, tapered head, self - drilling screw. Minimum of 5 threads beyond the combined thickness of he siding and steel stud framing. inimum steel framing thickness of 0.032 inch (8 mm) or 0 gauge. ies Strand Substrate lap must be fastened with: tud spacing a maximum spacing of 24 inches (610 mm) o.c. linimum #8 hot -dip galvanized, tapered head, self- rilling screw. linimum of 5 threads beyond the combined thickness of ie siding and steel stud framing. linimum steel framing thickness of 0.032 inch (8 mm) or 0 gauge. • D n¢t force siding into place. • D NOT USE STAPLES. • CI 6 cut the surface of the siding such that the rotation of the bl de cuts downward on the primed or prefinished surface. • el((e siding butts window trim, door casings and masonry, eil. Leave a 3/16 inch (S mm) gap and seal. Insrlated Sheathings LP r I rtSide lap sidings may be installed over low -compression, rigi foam insulation sheathing or exterior gypsum. The following preiri u-ions must be followed: •ejuate bracing of the wall in accordance with the e national Building Codes or other ruling building codes is ired. igid foam insulation sheathing up to 1 inch (2S mm) thick, i't1m) maybe nailed directly to the foam sheathing unless nage plane is required by the local building code. Nail I h must be increased to ensure a minimum 1-1/2 inch ( 8fastener penetration into the structural framing. • ri igid foam insulation sheathing greater than 1 inch (25 mm), nimum 1-1/2 inches (38 mm) thick by 3-1/2 inches (89 mm) d vertical strap. or furring strip must be installed over the HORIZONTAL BELTLINE JOINTS multi -story buildings, make provisions at horizontal joints "setting" shrinkage of framing, especially when applying BAND BOARD over PANEL FILLER Panel siding 3/8" gap Sloped flashing with 4" vertical leg 2"x Band board Filler Board — Panel siding Figure 6 Extend siding below Flashing IE sill plate Min. 1/8" or ii flashing between siding and masonry Masonry foundation C. li Figure 7A ,i Figure 78 is r IbGAP, FLASHDOORS eb Interior \ ;i Finish j��Siding �F ' Install window/door per manufacturer's instructions Figure 8 WRB 3/8"gap Sloped flashing — 4" vertical leg Trim Nail fin (do not damage) Fintlru9 I Aigiiiislili&Scant face width 1/8" gap SPACE JOINT 1/8" r to nailing instructions \ 1/8" gap LP p eI sidings are accepted by the State of California as category 8140 Exterior wall siding and sheathing for Wildland Urban Interface (WU aiplications. For WUI compliance, install LP panel sidings in acco ace with Louisiana-Pacific's printed application instructions withJF�i addition of fire retardant seal (UL Listed fire caulk, nominal 1/4 ih bead) in the vertical joint and nailing pattern of 3 inch o.c. peri rnailing / 8 inch o.c, field nailing. Look for the California Stat a Marshal Office label on our siding. The ui siana-Pacific Corporation ("LP") LP SmartSideSiding (the "Pro s") limited warranty (the "Warranty") applies onlyto stru u s on which the Products have been applied, finished and mai ai ed in accordance with the published application, finishing and a ntenance instructions in effect at the time of application. The all ire to follow such application, finishing or maintenance insti, ct ons will void the Warranty as to the portion of the Products affedec by the variance (the "Affected Products"). LP a u es no liability' or any loss or damage sustained by the Affetei I Products and is expressly released by the purchaser or owner fro such loss or liability. Any of ification of the Warranty's application, finishing or mai enance requirements is void and unenforceable unless approved in w I g prior to application by the Siding General Manager or his desi a and a member of the LP Legal Department. For o 3Y of the warranty or for installation and technical support, visit the LP S a tSide product support Web site at: wykIpsmartside.com or fi a iditional support call 800-648-6893. W ANTV REMEDIES ARE NOT AVAILABLE IF RE IREMENTS ARE NOT FOLLOWED. Cal op 65 Warning: Use of this product may result in ex s re to wood dust, known to the State of California to u e cancer. OJTSmartSide° TRIM & SIDING 020. Louisiana-Pacific Corporation. All rights reserved. LP, SmartSide, SilverTech and SmartFinish are r st red trademarks of Louisiana-Pacific Corporation. Printed In U.S.A. NOT Louisiana-Pacific Corporation periodically updates and revises its product information. that this version is current, call 800-648-6893. In Over Openings APPLICATION INSTRUCTIONS (CONTJ Alter , to Butt Joint Treatments