Loading...
HomeMy WebLinkAboutApproved Drawingsti HC GENERAL NOTES 1. HOLES: Holes are by others unless otherwise indicated. Fields -cut holes thru the units may not cut prestressed strands without prior written approval from Pre -Cast Specialties Inc. Engineering Department. 2. VERTICAL RISERS: The general contractor shall insure that vertical risers, etc., do not interfere with placement of Hollow Core units. 3. HANDLING: Hollow Core units may not be lifted by inserting hooks, bars or other lifting devices into the voids, and may not be inverted. Hallow Core units must be lifted V-0" from the end only. 4. DIMENSIONS AND DETAILS: The customer and/or his agent will be responsible for all dimension and details taken from the contract drawings and shown hereon. PCSI will not be responsible for any changes made after approval of these drawings. 5. ROOF UNITS: Slight vertical movement of precast concrete roof units is anticipated but can be reduced by proper insulation. PCSI recommends a physical separation of the plaster at the intersection of non -bearing walls and ceilings. 6. CAMBER: Camber is an inherent condition in all prestressed flexural members and the general contractor shall make allowances for same. If additional thickness of topping is needed for leveling purposes, contact our engineering department for approval. Highest estimated camber at time of erection: --- 7. CONCRETE: Strength of concrete shall be a minimum of 6000 psi at 28 days. Structural topping where specified shall be of 4000 psi 28 day strength concrete, reinforced with 6 x 6 - 10/10 welded wire mesh. or fiber reinforced concrete. The thickness of such topping shall be a minimum of 2 inches at the center of the span and may vary due to camber or deflection from the center to the supports as required for a level surface. The topping pour and all materials required some are by others. 8. GROUTING: All joints between slabs shall be fully packed with a pourable grout consisting of 1 part Portland Cement to 3 parts clean sand. The grouted deck shall be allowed to cure before removing any leveling shores, cutting any holes or applying any further construction loads. THE OPERATION OF GROUTING THE HOLLOW CORE SLABS KEYWAYS MUST BE PERFORMED REGARDLESS OF ANY TOPPING BEING APPLIED TO HOLLOW CORE SLABS. 9. PRESTRESSED STRANDS: Strands to be 7 wire, 7/16" dia., tensioned to 21700 lbs. each for 6" planks. (7 wire, 1/2" dia., tensioned to 28900 lbs. for 8" & 10" planks). The number of strands are indicated by the first two digits following the letter HC or US in the designation. 10. TOLERANCES: Width Full Width Units t 1/4" Saw Cut Units t 1/2" Split Units t 1 1/2" 11. DESIGN LOADS: Length f 1„ Thickness t 1/4" Deviation From Square t 1" 2nd. FLOOR: 8" U.S. W/65 P.S.F. (L.L.= 40 P.S.F. + D.L.= 25 P.S.F.) & ±2" TOPPING 2nd. FLOOR: 6" U.S. W/100 P.S.F. (L.L.= 80 P.S.F. + D.L.= 20 P.S.F.) & ±2" TOPPING 3rd. FLOOR: 8" U.S. W/65 P.S.F. (L.L.= 40 P.S.F. + D.L.= 25 P.S.F.) & ±2" TOPPING 3rd. FLOOR: 6" U.S. W/100 P.S.F. (L.L.= 80 P.S.F. + D.L. 20 P.S.F.) & ±2" TOPPING 12. Minor cracking (hairline and tension) will occur in precast/prestressed Concrete created by shrinkage of concrete and temporary loads during production, transportation or erection without being structurally detrimental to the units. These cracks have no structural significance and does not affect durability of these units. Cracking should not be cause for rejection, when properly repaired. 13. FIRE RESISTANCE: All Precast/Prestressed concrete products shown on these shop drawings have a maximum fire resistance of one (1) hour, unless indicated otherwise 14. All Precast/Prestressed concrete products shown on these shop drawings are structural quality, any rework/finishing necessary for final architectural appearance is by others. 15. TIE BEAMS: Tie beams must be true, level and free of knots. If precast perimeter beams or knockout blocks are used, they must be COMPLETELY FILLED. 16. ACCESS: General Contractor agrees to provide and maintain for the duration of precast installation, stabilized access, acceptable to PCSI so trucks and cranes can move under their own power to various points of erection with no overhead obstruction. Customer accepts all liability for deliveries beyond the curb line, including all underground utilities and cost for loss of time. PCSI reserves the right to stop deliveries and/or erection in the event such conditions are not provided. A THIS SYMBOL INDICATES SAWCUT OR SPLIT EDGE OF HOLLOW CORE PLANKS, - WHERE STRUCTURAL TOPPING IS TO BE APPLIED, PLANKS ARE TO BE THOROUGHLY CLEANED AND PREPARED BY G.C. PRIOR TO TOPPING TO INSURE ADEQUATE BOND STRENGTH. - TIE BEAMS MUST BE TRUE, LEVEL AND FREE OF KNOTS. IF PRECAST PERIMETER BEAMS OR KNOCKOUT BLOCKS ARE USED, THEY MUST BE COMPLETELY FILLED. - ALL NON BEARING WALLS SHOULD BE HELD DOWN 1" UNTIL SLABS ARE SET AND GROUTED AND ALL DEAD LOADS ARE APPLIED TO THE SLABS BEFORE DRY PACKING THE GAP BETWEEN THE NON BEARING WALL AND THE SLAB. - Dowels must be placed in the beams in a manner to allow the proper bearing of our product as detailed in our different sections. Non compliance with this item may delay the erection of these product with additional cost to the General Contractor. - SAFETY REQUIREMENTS: ALL SAFETY RAILING AND HOLE PROTECTION VIA SECURED PLYWOOD ARE BY G.C. IMMEDIATELY AFTER PRECAST/ PRESTRESSED MATERIALS ARE INSTALLED. GROUTING WILL NOT TAKE PLACE UNTIL ALL HOLES & RAILING ARE IN PLACE BY G.C. - MINIMUM BEARING: 2" BEARING IS STRUCTURALLY ACCEPTABLE, GENERAL CONTRACTOR MUST ADD 2 #5 REBAR 03'-0" LONG WITH 6" HOOK AT EDGE POUR PER SLAB. BEARING LESS THAN 2" MUST BE APPROVED BY PCSI ENGINEER. - SPLIT SLABS (NARROW DOWN): DUE TO MANUFACTURING & CONSTRUCTION TOLERANCES THERE MAY BE A GAPS BETWEEN SLABS AND OR WALLS. FIELD SPLIT SLABS WILL HAVE A ROUGH EDGE GAP, ALL GAPS SHALL BE FORMED AND POURED BY CONTRACTOR. CUTOUTS/NOTCHOUTS: TOLERANCE GAPS MAY OCCUR AROUND COLUMNS, BEAMS REBAR, PIPES, ETC. THESE GAPS SHALL BE FORMED AND POURED BY CONTRACTOR. ALLOWABLE LOADS HOLLOW CORE (US) SCHEDULE with topping no topping Rev. Unit No. Req. 2nd. FL No. Req. 3rd. FL L(incheq L(FEET) total length W(inches Length Width Remarks 65 rMark 8" US-058 5 0 327 27.25 1635 48 27' 3"4' 0" 8" US-058 1 0 327 27.25 327 25.5 27' 3"2' 11/2" SAWCUT 8" US-058 1 0 327 27.25 327 48 27' 3" 4' 0" W/C.O. 2 8" US-038 3 0 159 13.25 477 48 13' 3" 4' 0" 3 8" US-038 1 0 69 5.75 69 48 1 5' 9" 4' 0" 3A 8" US-038 1 1 0 69 5.75 69 30.5 5' 9" 2' 61/2" SAWCUT 4 8" US-038 0 238.5 19.88 954 48 19' 10 1/2" 4' 0" 4A 8" US-038 1 0 238.5 19.88 238.5 27 19' 10 1/2" 2' 3" SAWCUT 4B 8" US-038 1 0 238.5 19.88 238.5 48 19' 10 1/2" 4' 0" W/C.O. 5 8" US-038 4 0 86.5 7.21 346 48 7' 2 1/2" 4' 0" 6A 8" US-038 1 0 86.5 7.21 86.5 22 1 7' 2 1/2" 1' 10" SAWCUT 100 20 6" US-037 E 0 118.5 9.88 711 48 9' 10 1/2" 4' 0" 20A 6" US-037 1 0 118.5 9.88 118.5 26 9' 10 1/2" 2' 2" SAWCUT 65 50 8" US-058 0 7 327 27.25 2289 48 27' 3" 4' 0" 50A 8" US-058 C 1 327 27.25 327 26 27' 3" 2' 2" SAWCUT 50B 8" US-058 0 1 327 27.25 327 33 27' 3" 2' 9" SAWCUT 50C 8" US-058 0 1 327 27.25 327 48 27' 3" 4' 0" W/C.O. 50D 8" US-058 0 1 327 27.25 327 41.5 27' 3" 3' 5 1/2" SAWCUT 51 8" US-038 0 3 159 13.25 477 48 13' 3" 4' 0" 52 8" US-038 0 1 69 5.75 69 48 1 5' 9" 4' 0" 52A 8" US-038 0 1 69 5.75 69 30.5 5' 9" 2' 61/2" SAWCUT 53A 8" US-038 0 1 163 13.58 163 34 13' 7" 2' 10" SAWCUT 54 8" US-038 0 2 119 9.92 238 48 9' 11" 4' 0" 55A 8" US-058 0 1 119 9.92 1 119 19 9' 11" 1' 7" SAWCUT 0 0 100 70 6" US-037 0 4 119 9.92 476 48 9' 11" 4' 0" TOTAL 30 24 10805 900' 5" MISCELLANEOUS MATERIALS SCHEDULE REV. MK. No. MATERIAL No Required 2nd. FLOOR No Required 3rd. FLOOR REMARKS - M-A 1/8"x3"x47" KOROLATH STRIPS 60 48 H.C. BEARING ST. LU477 C._ .. PY"FWED FOIL C A LIA 'CE �VIL 1Y liL � DXfE PLANS AND rlStf NTTT Y tUST .. F. Irr. PT ON J03 OR NO nSPECTION WILL BE 1VIADE. IBC) [9_/27 j17 THESE PLANS AND ALL PROPOSED W' ARE SUEJECT To ANY CORRECTIONS REOUIRED EY FIELD INSPECTORS TH, M1,y 8E NECESSARY IN ORDER TO CO�•,PLY WIT" ALL APPLICABLE COD' CONCEALED FASTENERS OR ATTACHM ARE THE RESPONSI9ILITY OF THE CONTRACTOR OF RECORD RECEIVED OCT 2 5 2017 PERRAITTING St. Lucie County, FL PRE-CAST/PRESTRESS ENGR. JOHN P McGREW P.E. FLORIDA P.E. NO: 26641 ENGR. DATE SEAL 1 �� T PROJECT: MEDINA RESIDENCE 4876 WATERSONG WAY Ft. PIERCE CONTR.: COASTAL CONST. & DESING TEL.: (772)219-2180 APPROVED DATE SHEET N0. WO#: P-17-6327 S P EL C t: A u T I C Pre -Cast Specialties, LLC 1380 N.E. 48th. St. Pompano Beach, FL. 33064 PHONE: 954 781-4040 5$t.r A5_= 7BJ-; 11194 CHECKED DATE J.C. 9/27/17 _ DATE DESCRIPTION BY DRAWN DATE J.B. 8/28/17 - REVISIONS a O C FRAMING SECOND FLOOR A 8" U.S. W/65 P.S.F. & t2" TOPPING 6" U.S. W/100 P.S.F. & f2" TOPPING 74'-P" �D a 0 71'-8" a 0 I 00 al APPROVED ,, DRAWINGS PRE-CAST/PRESTRESS ENGR. 9 26 17 JOHN P McGREW P.E. FLORIDA P.E. NO: 26641 ENGR. DATE SEAL ��� ( 1 r PROJECT: MEDINA RESIDENCE 4876 WATERSONt WAY Ft PIERCE CONTR.: COASTAL CONST. & DESIGN TEL.: (772)219-2180 APPROVED DATE 9/26/17 SHEET NO. - 2.0 - WD# P-17-6327 c [ A L T I E Pre -Cast Specialties, LLC 1380 N.E. 48th. St. Pompano Beach, FL. 3306 PHONE (954) 781-4040 FAX, 954-781-1194 CHECKED DATE J.C. 9/27/17 - - _ DATE DESCRIPTION BY DRAWN DATE J.B. 8/28/17 REVISIONS — u THIRD FLOOR 1 n'-4" 54'-2" 1� 9'-4" 1�� 4� 25'-0" 5'-1""!, 21'-5" 8" U.S. W/65 P.S.F & f2" TOPPING 6" U.S. W/100 P.S.F. i & t2" TOPPING 67'-10" p - I - DATE DESCRIPTION — REVISIONS — ENGR. DATE SEAL ��l� I�tI�I h CHECKED DATE J.C. 9/27/17 _ BY DRAWN DATE J. B. 8/28/17 10*11110I611111 0 M a1 APPROVED DRAWINGS MEDINA RESIDENCE 4876 WATERSONG WAY Ft PIERCE CONTR.: COASTAL CONST. Sc DESIGN TEL.: (772)219-2180 PRE-CAST/PRESTRESS ENGR. g 2 17 JOHN P McGREW P.E. FLORIDA P.E. NO: 26641 APPROVED SHEE 2 1❑— P- 1'7-6327 P Pre -Cast Specialties, LLC ME, 48th. St, Pompano Beach, FL, 330 (954) 781-4040 FAX, 954-781.1194 f2" TOPPING (by G.C.) SECONDARY POUR (by G.C.) . L #4 BAR CAST IN BEAM AT--,.It",\-8" U.S. 4'-0" O.C., #3 BAR CONT. AND #4 x 1 -6" LG BAR 3 1 2"t 3 4" BF GROUTED IN CORE, ONE PER PLANK. (by G.C.) 8" MASONRY WALL W/REINF. (by G.C.) 1 SECTION 3.0 SCALE: 3/4" = 1'-0" GROUTING BUTT JOINTS (by G.C.) t2 T (by G.IC ) 8" U.S.-j r i 8" U.S. 3" t 1 2" BRG. 3"f 1 2" BRG. #4 HOOKED BAR CAST IN 8" MASONRY WALL BEAM ® 4'-0" O.0 & REINF. (by G.C. AND #4 BAR HORIZONTAL IN W / ) CORE, ONE PER PLANK. (by G.C.) 6 SECTION 3. o SCALE: 3/4" = 1'-D" SECONDARY POUR (by G.C.) #4 BAR CAST IN TOPPING 4'-0" O.C., AND 3 BAR CONTINUOUS. by G.C.) t2" TOPPIN (by G.C. �• 0 0 8" U.S. LAP VARIES 8" CONC. BEAM CB-8 (by G.C.) 11 SECTION 3 00 SCALE: 3/4" = 1'-0" SECONDARY POUR (by G.C.) #4 BAR CAST IN TOPPING 4'-0" D.C., AND #3 BAR CONTINUOUS. by G.C.) t2" TOPPIN� (by G.C. !3 U.S. LAP VARIES 8" MASONRY WALL W/REINF. (by G.C.) 2 SECTION 3.0 SCALE: 3/4" = 1'-0" #4 BAR CAST IN TOPPING 4'-0" O.C., AND t2" TOtVARIES #3 BAR CONTINUOUS. (by (by G.C.) SECONDARY POUR (by G.C.) d a 8" U.S° LAP n 8" MASONRY WALL- W/REINF. (by G.C.) rySECTION 3.0 SCALE: 3/4" = 7-0" #5 BAR CAST IN BEAM AT 4'-0" O.C., #4 BAR CONT. & #4x 1'-6" LG BAR GROUTED IN CORE, ONE PER PLANK. (by G.C) t2" TOPPIN t2" OPPIN (by G.C. (Tby G.C� 00 ° d . #5 BAR CAST IN BEAM AT #5 BAR CAST IN BEAM AT 4' -0" O.C., #4 BAR CONT. & 4'-0" O.C., #4 BAR CONT. & #4x 1'-6" LG BAR GROUTED IN t2" TOPPIN 2" TOPPING #4x 1'-6" LG BAR GROUTED IN CORE, ONE PER PLANK. (by G.C� tby G.C.) CORE, ONE PER PLANK. (by G.C) (by G.C) t2" TOPPIN� d -- - -- -?'. _ -- .. #by G.C) 1. 0 0 8" U.S. 8' U.S. e < 6" U.S. d ° 6" U.S. 3 1 2"t 3 4" BRG. ° LAP VARIES LAP VARIES 3 t1 2" BRG. ° CAST W/BEAM W1x4 CAST W/BEAM W1x4 d CONCRETE BEAM BAR CONT. IN 4" SECTION BAR CONT. IN 4" SECTION CONCRETE BEAM CB-5 (by G.C.) a° (BY G.C.) (BY G.C.) a CB-5 (by G.C.) 3 SECTION_ 4 SECTION 3.0 SCALE: 3/4" = 7'-0" q.0 SCALE: 3/4" = 1'-0'° SLAB (BY G.C.) 8" U.S. J �8" U.S. 3 1 2"t 3/4" BRG. LAP VARIES CAST W/BEAM W1x4 CONCRETE BEAM -�- BAR CONT. IN 4" SECTION CB-5 (by G.C.) a (BY G.C.) 12 SECTION 3 00 SCALE: 3/4" = 1'-0" SECONDARY POUR (by G.C.) #4 BAR CAST IN BEAM AT 4'-0" O.C., #3 BAR CONT AND #4 x 1 -6" LG BAR GROUTED IN CORE, ONE PER PLANK. (by G.C.) t2" TOPPING (by G.C.) .. < k L '-6" U.S. a 3 1 2"t 3 4" BRG 8" MASONRY WALL W/REINF. (by G.C.) a SECTION 3.0 SCALE: 3/;" = 1'-O" 0 DESCRIPTION REVISIONS SECONDARY POUR (by G.C.) #4 BAR CAST IN TOPPING 4'-0" O.C., AND 3 BAR CONTINUOUS. by G.C.) f2" TOPPIN� (by G.C. �.; 0 O e' 6" U.S. LAP VARIES 8" MASONRY WALL W/REINF. (by G.C.) 9 SECTION 3.0 SCALE: 3/4" = 1'-0" ENGR CHECKED _ J.C. BY DRAWN J.B. DATE SEAL DATE 9/27/17 DATE 8/28/17 GROUTING BUTT (by G.C.) 00 8" U.S.-/ LAP VARIES 8" MASONRY WALL — W/REINF. (by G.C.) t2" TOPPING (by G.C.) �1. 0O 8" U.S. LAP VARIES #4 HOOKED BAR CAST IN BEAM ® 4'-0" O.C., AND #3 BAR CONT. (by G.C.) 5 SECTION 3.0 SCALE: 3/4" = 1'-0" #4 BAR CASTAPOURN 4'-0" O.C., 3 BAR CONt2" TOPPIN� by G.C.)(by G.C. SECOND(by- - - -t2" TOPPING00(by G.C.)8"U.S. 6" U.S LAP VARIES 8" MASONRY WALL W/REINF. (by G.C.) 10 SECTION 3.0 SCALE: 3/4" = 1'-0" APPROVED DRAWINGS PROJECT: MEDINA RESIDENCE 4876 WATERSONG WAY Ft. PIERCE CONTR.: COASTAL CONST, & DESIGN TEL.: (772)219-2180 9 27 17 PRE-CAST/PRESTRESS ENGR. JOHN P McGREW P.E. FLORIDA P.E. NO: 26641 APPROVED DATE SHEET NO. WO#: 9/26/17 - 3.0 - P-17-6327 S: P E G I A II I V 5 Pre —Cast Specialties, LLC 1380 N.E. 48th. St. Pompano Beact�,;,FL. 3