:The building or dwelling unitshall be tested and`verified as having an air leakage: rate of not exceeding 7 air changes per
.hour in Climate Zone 1,:2 and 3 air changes per hour in Climate Zones 3 ahrough'8: Testing shall be conducted with a
blower.door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in -
Section:553.993(5) or (Z), Florida Statutes or individuals licensed as set forth in Section,489.,105 (3)(f),.(g) or.(i) or an
,approved third party.. A:written report of the results of the test shall be signed by. the. party conducting the test and
Provided to the code officidl. Testing shall.be performed at any time after.creation of.all penetrations of the building . .
thermal envelope.. . :.
FBC, Residential
Where;the.air.infiltration rate of. a dwelling.unit is less than�.5 a.ir.chariges per hour when tested with a blower door at a
pressure of 0.2 inch, w. c.. (50,Pa) in.accordance with Section R402.4..1.2 of the Florida Building Code, Energy Zoriservation
the -dwelling unit shall be provided with whole=house mechanical ventilation in accordance with Section IV11507.3.
Testing Company
GFA International .Inca 607 NW:Commodity Cove, Port-St..Lucid, Florida
Company Name: Address:
I hereby certify that the abovektuseVfiltrati6n results demonstrate compliance with FBC Energy Conservation
regyireme.nts in accopdance ith Secti nR402.4.i.2 Climate-Zone'2. .
signature:
Printed Name: Michael Anderson
License/Certification #: BP15059963