Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Certificate For Design Load Compliance
Planning 8( Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Medina residence Project Address: 74876Watersong Way, Fort Pierce FL 34949 Permit #: Occupancy Type: residential Construction Type: concrete block INSTRUCTIONS FOR USE: � ^ 3 • This certification must be completed, signed, and sealed by the design professional of record. Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: gyp• New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida `4 ® % Code Fifth Edition with 20 /7 Supplements using SCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed _, Open 3. Risk Category: _I L II III _ IVExposure Category: B _C I(`� D 4. Design Wind Velocity 00 mph VAS _LRFD End Zone Width: — � ft 5. Mean Roof Height 3 j — ft Roof Pitch: :12 Parapet: PJ t' ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1:'¢ G + Zone 2: 7 3. Zone 3: / ' Zone 4: ' L Zone 5: (a S Garage: 5 9,e44 z 7. Design Loads: Floor: ¢0 4 PSF Roof/Dead: Z PSF Roof/Live: 3 0 Balcony: PSF LWL- 4., c., s Dock: N A 'PSF Deck: PSF Stairs: *0 PSF Fence: —" PSF Railings: ZoD {6f' Lo �r 8. Were Shear Walls Considered For Structure? (/ Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? f/ Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 0 PSF Soil Test Reports Submitted? t-'Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: / - S',an �- � s f3 o s � vase# P E z n �! • nature, Date, and Seal Revised 07/25/2014 Print Name Cert # & Co. Cert Auth. T _4 —I Company Name & Address 33©G4