Loading...
HomeMy WebLinkAboutConcrete Test ReportHutting �7�L -�� 0 —STM C-31 CONCRETE ga Engineers �= Concrete Compressive Strength TEST REPORT tAASHTO' R1B You►Profectis our Commitment TO Bodax Foundations PROJECT NO. PSL-1377 ,• 1101 NW 55th Street CLIENT Bodax Foun ,. Ft. Lauderdale, FL 33309 C.C. r 4o.64 OCT 1 1 2017 ATTN: Tom Butler' BY: PROJECT proposed Residence LOCATION Lot 50, 4876 Watersong Way Hutchinson Island, F SET NO. 1 NO. OF SPECIMENS 4 DATE RECEIVED Oct 03, 2017 DATE CAST Sep 21, 2017 SPECIMEN NUMBER DATE TESTED AGE AT TEST (DAYS) AVERAGE DIAMETER (inch) OR SIDE (inch x inch) AVERAGE LENGTH OR SPAN (inch) MAXIMUM LOAD (lb) AVERAGE CROSS -SECTIONAL AREA (inch') COMPRESSIVE OR FLEXURAL STRENGTH (psi) FAILURE TYPE CA CB CC CD Sep 28 Oct 19 Oct 19 Oct 19 7 28 28 28 3.01 3.03 3.01 3.02 6.00 6.00 6.00 6.00 30210 7.12 7.21 7.12 7.16 4246 A E. C D E F MIX ID P0500ACG TYPE OF MIX GROUT CONCRETE TEMPERATURE C-1064 88 SPECIFIED STRENGTH 5000 Psi @ 28 DAYS MEASURED SLUMP C-143 9.00 inch BATCH TIME 10 : 35 MEASURED AIR C-231 NA % SUPPLIER Adonel Concrete CAST TIME 11. 15 TRUCK NO. 4 0 0 2 TICKET NO. 110 0 LOAD VOL. 9 yd 3 Nutting Engineers of Florida, Inc. Boynton Beach 561-736-4900 Pompano 954-941-8700 Miami -Dade 305-824-0060 Port St. Lucie 772-408-1050 Toll Free 877-NUTTING 3 Web:._ www.nuftingengineers.com OF CAST BY S D MOULD TYPE WATER ADDED 15.0 gal AUTH. BY PUMP LOCATION AUGER CAST PILES, PILE VS 1, 36, 5, 24, 44, 12, 11 COMMENTS Nutting Engineers of Florida, Inc. PER, Page 1, of 1 Oct 05, 2017 James J. Flaig, RE. #21083 These test results constitute a testing service only. Engineering interpretation or evaluation of results is provided only on written request. I1tel Nutting �_S8TM C-31 ge Engineers "Concrete Compressive Strength or morida Inc.I Esiabllshetl 1907 YourProjectis Our Commitment Bodax Foundations 1101 NW 55th Street Ft. Lauderdale, FL 33309 ATTN: Tom Butler PROJECT proposed Residence SET NO. 2 NO. OF SPECIMENS 4 R 'ASHTO'R18. CONCRETE TEST REPORT PROJECTNO. PSL-1377 CLIENT Bodax Found V C.C. �, V ., OCT 1 12017 Mr LOCATION Lot 50, 4876' Hutchinson Island, F DATE RECEIVED Oct 03, 2017 DATE CAST Sep .22, 2017 SPECIMEN NUMBER DATE TESTED AGE AT TEST (DAYS). AVERAGE DIAMETER (inch) OR SIDE (inch x inch) AVERAGE: LENGTH OR, SPAN (inch) MAXIMUM LOAD (lb) AVERAGE ' CROSS -SECTIONAL AREA (inchz) COMPRESSIVE OR FLEXURAL STRENGTH (psi) FAILURE TYPE CA Sep 29 7 3.01 6.00 32296 7.12 4539 5 A CB Oct 20 28 3.01 6.00 7.12 B C CC Oct 20 28 3.03 6.00 7.21 D CD Oct 20 28 3.01 6.00 7.12 E F MIX ID P0500ACG TYPE OF MIX GROUT CONCRETE TEMPERATURE C-1064 88 °F SPECIFIED STRENGTH 5000 Psi @ 28 DAYS MEASURED SLUMP C-143 9.00 inch CAST BY SD BATCH TIME 0 8 : 0 0 MEASURED AIR C-231 NA % MOULD TYPE SUPPLIER Adonel Concrete CAST TIME 08 : 51 TRUCK NO. 7 0 01 TICKET NO. 110 5 WATER ADDED 15.0 gal AUTH. BY PUMP LOAD VOL. 9 yd 3 LOCATION AUGER CAST PILES, PILE VS Nutting Engineers of Florida, Inc. 38, 13, 16, 30, 47, 32, 18, 13 Boynton Beach 561-736-4900 Pompano 954-941-8700 COMMENTS Miami -Dade 305-824-0060 Port St. Lucie 772-408-1050 Toll Free 877-NUTTING 3 Web: www.nufingengineers.com Nutting Engineers of Florida, Inc. PER. Page 1 of 1 Oct 05,2017 James J.Flai RE.#21083 These test results constitute a testing service only. Engineering interpretation or evaluation of results is provided only on written request.