HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MEDINA RESIDENCE Builder Name: Street: SITE 50 WATERSONG Permit Office: City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) I. New construction or existing New (From Plans) 9. Wall Types (5178.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=20.0 4982.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=19.0 196.00 ft2 c. NIA R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1987.0 sqft.) Insulation Area 6. Conditioned floor area above grade (ft2) 4166 a. Roof Deck (Unvented) b. N/A R=22.0 1987.00 ft2 R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(975.1 sqft.) Description Area 11. Ducts a. Sup: Attic, Ret: Attic, AH: CLOSET R ft2 6 425 a. U-Factor: Dbl, U=0.79 463.11 ft2 b. Sup: Attic, Ret: Attic, AH: Room22 6 325 SHGC: SHGC=0.28 b. U-Factor. Dbl, U=1.06 320.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.39 a. Central Unit 48.0 SEER:17.00 c. U-Factor: Dbl, U=1.06 96.00 ft2 b. Central Unit 36.0 SEER:17.50 SHGC: SHGC=0.30 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 96.00 ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: other (see details) b. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 5.087 ft. Area Weighted Average SHGC: 0.311 14. Hot water systems 8. Floor Types (1985.0 sqft.) Insulation Area a. Electric Cap: 80 gallons a. Slab -On -Grade Edge Insulation R=0.0 1250.00 ft2 b. Conservation features EF: 0.950 b. Raised Floor R=19.0 735.00 ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.234 Total Proposed Modified Loads: 145.05 PASS Total Baseline Loads: 145.20 I hereby certify that the plans and specifications covered by Review of the plans and ST,q?� this calculation are in compliance with the Florida Energy specifications covered by this O�-t9E Code. calculation indicates compliance ,,/'� _ ' ��,o V6 PREPwith the Florida Energy Code. Before construction is completed DATE: DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, esig d, is in compliance the Florida Florida Statutes. y� � with Energy Code CpD WE, OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 8/23/2017 10:32 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 7 FORM R405-2014 PROJECT Title: MEDINA RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 4166 Lot # Owner: Total Stories: 3 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: SITE 50 WATERSONG Permit Office: Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: ST. LUCIE COUNTY, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V/ Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU #1 2659 29764 2 AHU #2 1507 15070 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 FOYER 335 3350 No 0 1 No Yes Yes 2 FLEX SPACE 378 3780 No 0 1 No Yes Yes 3 LAUNDRY/ENTRY 80 800 No 0 1 No Yes Yes 4 BEACH BATH 130 1300 No 0 1 No Yes Yes 5 STAIRS 87 870 No 0 1 No Yes Yes 6 OCEAN ROOM 700 8400 No 2 1 No Yes Yes 7 ELEVATOR 36 432 No 0 1 No Yes Yes 8 STAIRWAY 104 1248 No 0 1 No Yes Yes 9 CLOSET 42 504 No 0 1 No Yes Yes 10 KITCHEN/DINING 340 4080 Yes 0 1 No Yes Yes 11 OFFICE 100 1200 No 0 1 No Yes Yes 12 BEDROOM 4 195 2340 No 1 1 1 No Yes Yes 13 CLST 4 30 360 No 0 1 No Yes Yes 14 ' POWDER 40 480 No 0 1 No Yes Yes 15 BATH 4 62 620 No 0 1 No Yes Yes 16 M. BEDROOM 300 3000 No 2 1 1 No Yes Yes 17 M.BATH 148 1480 No 0 1 No Yes Yes 18 Room22 64 640 No 0 1 No Yes Yes 19 HER 96 960 No 0 1 No Yes Yes 20 HIS 42 420 No 0 1 No Yes Yes 21 LAUNDRY 54 540 No 0 1 No Yes Yes 8/23/2017 10:32 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 7 FORM R405-2014 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 ELEV. 30 300 No 0 1 No Yes Yes 23 STAIRWAY. 168 1680 No 0 1 No Yes Yes 24 BATH 2 54 540 No 0 1 No Yes Yes 25 BEDROOM 2 194 1940 No 1 1 1 No Yes Yes 26 BATH 3 54 540 No 0 1 No Yes Yes 27 CLST.3 25 250 No 0 1 No Yes Yes 28 BEDROOM 3 202 2020 No 1 1 1 No Yes Yes 29 HALLWAY. 76 760 No 0 1 No Yes Yes FLOORS - # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio FOYER 37 ft 0 335 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio FLEX SPACE 39 ft 0 378 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio LAUNDRY/ENTR 18 ft 0 80 ft2 ____ 0 1 0 4 Slab -On -Grade Edge Insulatio BEACH BATH 13 ft 0 130 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio STAIRS 1 ft 0 87 ftz ---- 0 1 0 6 Slab -On -Grade Edge Insulatio OCEAN ROOM 26.7 ft 0 240 ft2 ____ 0 1 0 7 Raised Floor ELEV. ____ ____ 30 ft2 19 0 0 1 8 Raised Floor STAIRWAY. _--- ____ 111 ft2 19 0 0 1 9 Raised Floor BATH 2 ____ ____ 54 ft2 19 0 0 1 10Raised Floor BEDROOM 2 __-_ ---_ 194 ft2 19 0 0 1 11Raised Floor BATH 3 ---- _--- 48 ft2 19 0 1 0 12Raised Floor CLST. 3 ____ ____ 20 ft2 19 0 0 1 13Raised Floor CLST. 3 5 ft2 19 0 1 0 14Raised Floor BEDROOM 3 ---- ---- 78 ft2 19 0 0 1 15Raised Floor BEDROOM 3 ____ -_-- 124 ft2 19 0 1 0 16Raised Floor HALLWAY. ____ __-_ 67 ft2 19 0 0 1 17Raised Floor HALLWAY. __-- ____ 4 ft2 19 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 2096 ft2 330 ft2 Light 0.6 No 0.9 No 22 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1989 ft2 N Y FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) FLEX SPACE 22 Blown 196 ft2 0.1 Wood 2 Under Attic (Unvented) LAUNDRY/ENTR 22 Blown 42 ft2 0.1 Wood 3 Under Attic (Unvented) OCEAN ROOM 22 Blown 700 ft2 0.1 Wood 4 Under Attic (Unvented) ELEVATOR 22 Blown 36 ft2 0.1 Wood 5 Under Attic (Unvented) STAIRWAY 22 Blown 104 ft2 0.1 Wood 6 Under Attic (Unvented) CLOSET 22 Blown 42 ft2 0.1 Wood 7 Under Attic (Unvented) KITCHEN/DININ 22 Blown 340 ft2 0.1 Wood 8 Under Attic (Unvented) OFFICE 22 Blown 100 ft2 0.1 Wood 9 Under Attic (Unvented) BEDROOM 4 22 Blown 195 ft2 0.1 Wood 10 Under Attic (Unvented) CLST 4 22 Blown 30 ft2 0.1 Wood 11 Under Attic (Unvented) POWDER 22 Blown 40 ft2 0.1 Wood 12 Under Attic (Unvented) BATH 4 22 Blown 62 ft2 0.1 Wood 13 Under Attic (Unvented) BEDROOM 2 22 Blown 8 ft2 0.1 Wood 14 Under Attic (Unvented) BEDROOM 3 22 Blown 92 ft2 0.1 Wood WALLS Qrnt Adjacent Cavity To Wall Type SpaceEt Width Height n Et n Area Sheathing Framing Solar R-Nialue FmCtiO13 Ahqor Below 1 NE Exterior Concrete Block - Int Insul FOYER 20 12 0 10 0 120.0 ft2 0 0 0.5 0 2 SE Exterior Concrete Block - Int Insul FOYER 20 7 0 10 0 70.0 ft2 0 0 0.5 0 3 SW Exterior Concrete Block - Int Insul FOYER 20 18 0 10 0 180.0 ft2 0 0 0.5 0 4 SW Exterior Concrete Block - Int Ins6LEX SPACE 20 21 0 10 0 210.0 ft2 0 0 0.5 0 5 NW Exterior Concrete Block - Int InsBLEX SPACE 20 18 0 10 0 180.0 ft2 0 0 0.5 0 6 NE Exterior Concrete Block - Int InsiWAUNDRY/E 20 8 0 10 0 80.0 ft2 0 0 0.5 0 7 NW Exterior Concrete Block - Int InsddAUNDRY/E 20 15 0 10 0 150.0 ft2 0 0 0.5 0 _ 8 NE Exterior Concrete Block - Int InstSEACH BAT 20 13 0 10 0 130.0 ft2 0 0 0.5 0 9 NE Exterior Concrete Block - Int InsOCEAN ROO 20 25 0 12 0 300.0 ft2 0 0 0.5 0 10 SW Exterior Concrete Block - Int InsGICEAN ROO 20 25 0 12 0 300.0 ft2 0 0 0.5 0 11 NW Exterior Concrete Block - Int InsGICEAN ROO 20 28 0 12 0 336.0 ft2 0 0 0.5 0 12 NE Exterior Concrete Block - Int InSdELEVATOR 20 6 0 12 0 72.0 ft2 0 0 0.5 0 13 NE Exterior Concrete Block - Int Insul CLOSET 20 7 0 12 0 84.0 ft2 0 0 0.5 0 14 SW Exterior Concrete Block - Int InstKITCHEN/DI 20 21 0 12 0 252.0 ft2 0 0 0.5 0 15 NE Exterior Concrete Block - Int Insul OFFICE 20 10 0 12 0 120.0 ft2 0 0 0.5 0 _ 16 NE Exterior Concrete Block - Int InsBEDROOM 4 20 13 0 12 0 156.0 ft2 0 0 0.5 0 17 SE Exterior Concrete Block - Int InsBEDROOM 4 20 14 0 12 0 168.0 ft2 0 0 0.5 0 18 SW Exterior Concrete Block - Int InsBEDROOM 4 20 1 0 12 0 12.0 ft2 0 0 0.5 0 19 SE Exterior Concrete Block - Int Insul CLST 4 20 6 0 12 0 72.0 ft2 0 0 0.5 0 _20 SW Exterior Concrete Block - Int Insul CLST 4 20 5 0 12 0 60.0 ft2 0 0 0.5 0 _21 SE Exterior Concrete Block - Int Insul BATH 4 20 8 0 10 0 80.0 ft2 0 0 0.5 0 _22 SW Exterior Concrete Block - Int Insul BATH 4 20 9 0 10 0 90.0 ft2 0 0 0.5 0 _23 SW Exterior Concrete Block - Int InsiQll. BEDR00 20 15 0 10 0 150.0 ft2 0 0 0.5 0 _24 NW Exterior Concrete Block - Int InsLM. BEDROO 20 18 0 10 0 180.0 ft2 0 0 0.5 0 _25 NE Exterior Concrete Block - Int Insul M. BATH 20 15 0 10 0 150.0 ft2 0 0 0.5 0 _26 SW Exterior Concrete Block - Int Insul M. BATH 20 7 0 10 0 70.0 ft2 0 0 0.5 0 8/23/2017 10:32 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 7 FORM R405-2014 WALLS Ornt Adjacent Space In W:;If Type_Et Cavity Width In Height Et In Area Sheathing Framing R-Nlalue Fraction Solar Below Ahqor Grade% 27 NW Exterior Concrete Block - Int Insul M. BATH 20 10 0 10 0 100.0 ft2 0 0 0.5 0 _28 NE Exterior Concrete Block - Int Insul Room22 20 6 0 10 0 60.0 ft2 0 0 0.5 0 _29 SW Exterior Concrete Block - Int Insul HER 20 12 0 10 0 120.0 ft2 0 0 0.5 0 _30 NE Exterior Concrete Block - Int InsuLAUNDRY 20 7 0 10 0 70.0 ft2 0 0 0.5 0 _31 NE Exterior Concrete Block - Int Insul ELEV. 20 5 0 10 0 50.0 ft2 0 0 0.5 0 _32 NE Exterior Concrete Block - Int InstSTAIRWAY. 20 4 0 10 0 40.0 ft2 0 0 0.5 0 _33 NE Exterior Concrete Block - Int Insul BATH 2 20 9 0 10 0 90.0 ft2 0 0 6.5 0 34 NE Exterior Concrete Block - Int InsBEDROOM 2 20 11 0 10 0 110.0 ft2 0 0 0.5 0 35 SE Exterior Concrete Block - Int InsBEDROOM 2 20 15 0 10 0 150.0 ft2 0 0 0.5 0 _36 SW Exterior Concrete Block - Int Insul BATH 3 20 9 0 10 0 90.0 ft2 0 0 0.5 0 37 NE Exterior Concrete Block - Int InsBEDROOM 3 20 3 0 10 0 30.0 ft2 0 0 0.5 0 _38 SE Exterior Concrete Block - Int Ins8EDROOM 3 20 13 0 10 0 130.0 ft2 0 0 0.5 0 _39 SW Exterior Concrete Block - Int InsBEDROOM 3 20 17 0 10 0 170.0 ft2 0 0 0.5 0 _40 N Garage Frame - Wood HALLWAY. 19 21 9 4 196.0 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Wood FOYER None .2 .1 .1 .0 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang v # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NE 1 Vinyl Low-E Double Yes 0.79 0.28 25.8 ft2 2 ft 0 in 26 ft 0 in None None 2 SE 2 Vinyl Low-E Double Yes 0.22 0.17 48.0 ft2 2 ft 0 in 9 ft 0 in None None 3 SW 3 Vinyl Low-E Double Yes 0.79 0.28 25.8 ft2 2 ft 0 in 26 ft 0 in None None 4 SW 4 Vinyl Low-E Double Yes 0.79 0.28 40.0 ft2 2 ft 0 in 26 ft 0 in None None 5 NW 7 Vinyl Low-E Double Yes 0.22 0.17 24.0 ft2 2 ft 0 in 9 ft 0 in None None 6 NW 7 Vinyl Low-E Double Yes 1.06 0.3 96.0 ft2 3 ft 0 in 26 ft 0 in None None 7 NE 9 Vinyl Low-E Double Yes 0.79 0.28 32.5 ft2 2 ft 0 in 16 ft 0 in None None 8 SW 10 Vinyl Low-E Double Yes 0.79 0.28 32.5 ft2 2 ft 0 in 16 ft 0 in None None 9 NW 11 Vinyl Low-E Double Yes 1.06 0.39 240.0 ft2 11 ft 0 in 1 ft 4 in None None 10 SW 14 Vinyl Low-E Double Yes 0.79 0.28 22.0 ft2 2 ft 0 in 16 ft 0 in None None 11 SW 14 Vinyl Low-E Double Yes 0.79 0.28 32.5 ft2 2 ft 0 in 16 ft 0 in None None 12 NE 15 Vinyl Low-E Double Yes 0.79 0.28 25.0 ft2 2 ft 0 in 16 ft 0 in None None 13 SE 17 Vinyl Low-E Double Yes 0.79 0.28 13.5 ft2 4 ft 0 in 1 ft 4 in None None 14 SE 17 Vinyl Low-E Double Yes 0.79 0.28 12.1 ft2 2 ft 0 in 16 ft 0 in None None 15 SE 17 Vinyl Low-E Double Yes 0.79 0.28 43.3 ft2 4 ft 0 in 1 ft 4 in None None 16 SE 19 Vinyl Low-E Double Yes 0.79 0.28 12.1 ft2 2 ft 0 in 16 ft 0 in None None 17 SE 21 Vinyl Low-E Double Yes 0.79 0.28 12.1 ft2 2 ft 0 in 16 ft 0 in None None 18 SW 23 Vinyl Low-E Double Yes 0.79 0.28 20.0 ft2 2 ft 0 in 1 ft 4 in None None 19 NW 24 Vinyl Low-E Double Yes 1.06 0.39 80.0 ft2 10 ft 0 in 1 ft 4 in None None 20 NE 25 Vinyl Low-E Double Yes 0.79 0.28 6.0 ft2 2 ft 0 in 1 ft 4 in None None 8/23/2017 10:32 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 7 FORM R405-2014 V Wall # Ornt ID Frame Panes 21 NW 27 Vinyl Low-E Daub 22 NE 28 Vinyl Low-E Daub 23 NE 30 Vinyl Low-E Daub 24 NE 32 Vinyl Low-E Daub 25 NE 33 Vinyl Low-E Daub 26 NE 34 Vinyl Low-E Daub 27 SE 35 Vinyl Low-E Daub 28 SW 36 Vinyl Low-E Daub 29 SE 38 Vinyl Low-E Daub 30 SW 39 Vinyl Low-E Daub # Floor Area 1 460 ft2 # Scope Method 1 Wholehouse Proposed ACH(50) WINDOWS Orientation shown is the entered, Proposed orie NFRC U-Factor SHGC le Yes 0.81 0.31 2 HEATING SYSTEM ntation. 4 0 0 0 0 0 2 0 Overhang Area Depth Separation Int Shade .0 ft2 2 ft 0 in 1 ft 4 in None .0 ft2 2 ft 0 in 1 ft 4 in None .0 ft2 2 ft 0 in 1 ft 4 in None .0 ft' 2 ft 0 in 1 ft 4 in None .0 ft2 2 ft 0 in 1 ft 4 in None .0 ft2 2 ft 0 in 1 ft 4 in None .0 ft2 2 ft 0 in 1 ft 4 in None .3 ft2 2 ft 0 in 1 ft 4 in None .5 ft' 2 ft 0 in 1 ft 4 in None .0 ft2 2 ft 0 in 1 ft 4 in None Wall Height Exposed Wall Insulation 9.4 ft 19 ACH ACH 50 .4858 7 None None None None None None None None None None # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 34 kBtu/hr 1 sys#1 2 Electric Strip Heat None COP:1 27 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 17 48 kBtu/hr cfm 0.85 1 sys#1 2 Central Unit Split SEER: 17.5 36 kBtu/hr cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 80 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 8/23/201710:32 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 7 Wall Height Exposed Wall Insulation 9.4 ft 19 ACH ACH 50 .4858 7 None None None None None None None None None None # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 34 kBtu/hr 1 sys#1 2 Electric Strip Heat None COP:1 27 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 17 48 kBtu/hr cfm 0.85 1 sys#1 2 Central Unit Split SEER: 17.5 36 kBtu/hr cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 80 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 8/23/201710:32 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 7 8/23/201710:32 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2014 DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 425 ftZ Attic 75 ftZ Default Leakage CLOSET (Default) (Default) 1 1 2 Attic 6 325 ftz Attic 95 ftZ Default Leakage Room22 (Default) (Default) 2 2 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan HeatinJan [ ] Feb [X] Feb Mar Mar Apr Apr May May Jul Jun Jul rj Jun ri Aug Augri ri Se Sep Oct Nov HX Dec H Jan [ j Feb X Mar Jun Jul Aug Sep Oct Nov DecVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 8/23/2017 10:32 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 7 of 7 FORM R405-2014 TABLE 402.4.1. AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MEDINA RESIDENCE Builder Name: Street: SITE 50 WATERSONG Permit Office: City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. 'Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 8/23/2017 10:32 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. SITE 50 WATERSONG, ST. LUCIE COUNTY, FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Dbl, U=0.79 SHGC: SHGC=0.28 b. U-Factor: Dbl, U=1.06 SHGC: SHGC=0.39 c. U-Factor: Dbl, U=1.06 SHGC: SHGC=0.30 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. Raised Floor c. N/A I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final ins a n. O erwise, a new EPL Display Card will be completed de based on installed Coc�t feaftures. New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=20.0 4982.00 ft2 b. Frame - Wood, Adjacent R=19.0 196.00 ft2 1 c. N/A R= ft2 4 d. N/A R= ft2 No 10. Ceiling Types Insulation Area a. Roof Deck (Unvented) R=22.0 1987.00 ft2 4166 b. N/A R= ft2 Area c. N/A R= ft2 463.11 ft2 11. Ducts R fP a. Sup: Attic, Ret: Attic, AH: CLOSET 6 425 b. Sup: Attic, Ret: Attic, AH: Room22 6 325 320.00 ft2 12. Cooling systems kBtu/hr Efficiency 96.00 ft2 a. Central Unit 48.0 SEER:17.00 b. Central Unit 36.0 SEER:17.50 96.00 ft2 13. Heating systems kBtu/hr Efficiency 5.087 ft. a. Electric Strip Heat 34.0 COP:1.00 b. Electric Strip Heat 27.0 COP:1.00 0.311 Insulation Area R=0.0 1250.00 ft2 R=19.0 735.00 ft2 R= ft2 14. Hot water systems a. Electric Cap: 80 gallons EF: 0.95 b. Conservation features None 15. Credits Pstat Builder Signature: /`// / Date: g 2 17 Address of New Home: Y676, Wi4TXFA5oAJ6 WAY City/FL Zip: Fr fqg4<5 a FL 3tt`t 9(7 `Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/23/201710:32 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1