PROPERTY INFORMATION
Address: 4876 Watersong Way
City / State / Zip: Fort Pierce, FI 34949
Parcel M 2532-500-0064-000/1
Zoning: PUD
REVIEW COMMENTS
Owner(s):
Raul Medina
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 50 Block:
APPLICATION INFORMATION
Permit Number: 1706-0616 Stories:
Permit Type: BUILDING RESIDENTIAL (S R UP TO 2 FLOORS)
CONTRACTOR INFORMATION
Contractor Name: Mario P Arbucci
Business Name: Coastal Construction And D sign Inc
Business Addr: 1812 Nw Old Oak Terr
City / State / Zip: Jensen Beach, A 34957
REVIEWS AND COMMENTS
Review Type Status Reviewed By
ADDRESSING ASSIGNMENT COMPLETE Lydia Galbraith
Comment:
Page 1
Automatic Sprinkler System? No
Fax Number:
Email: Marbucci@Comcast.Net
Date Started Date Completed Date Released
7/11/2017 7/11/2017 7/11/2017
DOCUMENTS MISSING
PENDING Audrey Humphrey 6/28/2017
6/28/2017
Comment:
VEGETATION P RMIT IN BIN UNDER "M" MEDINA
ENVIRONMENTAL REVIEW
COMPLETE Lynn Swartzel 6129/2017 613012017 6/30/2017
Comment:
FRONT COUNTER REVIEW
COMPLETE Audrey Humphrey 6/28/2017 6/28/2017 6/28/2017
Comment:
PLANS EXAMINER REVIEW
INCOMPLETE William Durden 7/27/2017
Comment:
ENERGY CAL I'S CALL OUT ON LINE 7 ONLY ONE U-FACTOR IN SOLAR HEAT GAIN, PLANS SHOW MULTIPLE
7/28/2017
TYPES OF FE ESTRATION. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING. CODE.
Comment:
ENERGY CAL 'S CALLOUT R-20 ROOF DECK INSULATION, PLANS CALL OUT FOR R-30 INSULATION, PAGE
7/28/2017
A1.1 CALLS 0 T FOR OUR 20 INSULATION, TYPICAL WALL SECTION PAGE A7.1 CALLS OUT OR ARE 30
INSULATION, LEASE CORRECT. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE
Comment:
PAGE A5.1 V LLEY DETAIL CALLS OUT COMPOSITE SHINGLES PRODUCT REVIEW AFFIDAVIT ONLY
7/28/2017
SHOWS MET L STANDING SEAM ROOF PLEASE CORRECT. SEE SECTION 107 2014 FLORIDA BUILDING
CODE.
7/28/2017
Comment:
PLEASE SU MIT PRODUCT APPROVAL FOR ROOF UNDERLAYMENT. SEE SECTION 107 2014 FLORIDA
BUILDING CODE.
Planning & Development Services
Building & Code Regulation Division.
2300 Virginia Avenue
Fort Pierce, FL. 34082
Phone:(772)462-2172 Fax:(772)462-6443
REVIEW COMMENTS
Page 2
Comment: PAGE A5.5 A-4 EXTERIOR
OPENING SCHEDULE PRODUCT ATTACHMENT METHOD NOT COMPLETE
PLEASE SUBMIT PRODUC
APPROVALS OR COMPLETE PRODUCT REVIEW AFFIDAVIT.
• SUBMIT THE PRODUCT %
PROVALS, IN DUPLICATE OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH
7/28/2017 FLORIDA PRODUCT APPRQVAL
OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED
SEALED AND DATED BY T
E DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN
ACCORDANCE WITH 553.842
OF THE FLORIDA STATUTES. PRODUCT APPROVAL'S MUST BE HIGHLIGHTED
OR MARKED IDENTIFYING
HE OPENING OR CLADDING COMPONENTS, WITH FASTENERS AND DESIGN
PRESSURES. II
7/28/2017 Comment: NOA 12 - 0130.13 IS AN OL
TDATED NOA.
7/28/2017 Comment: ROOFING PRODUCT FLOF
JDA APPROVAL #12751.2 IS AN OUTDATED PRODUCT APPROVAL.
Comment: FRENCH DOOR FLORIDA ?RODUCT
APPROVAL NUMBER 15444 R-3 HAS MULTIPLE PRODUCT APPROVAL
7/28/2017 NUMBERS ATTACHED PLEI
SE SUBMIT CORRECT PRODUCT APPROVAL NUMBER.
Comment: GARAGE DOOR FLORIDA
RODUCT APPROVAL NUMBER 15371 R-1 HAS MULTIPLE PRODUCT APPROVAL
7/28/2017 NUMBERS ATTACHED PL
SE SUBMIT CORRECT PRODUCT APPROVAL NUMBER.
Comment: PLEASE SUBMIT HOLLO
CORE SYSTEM SHOP DRAWINGS FOR REVIEW SEEPAGE 86.1 HOLLOW CORE .
7/28/2017 SYSTEM NOTES.
Comment: SEE CONCRETE NOTES
N PAGE A 121 SPECIFIES 4000 PSI. MULTIPLE SECTIONS OF CONCRETE LIVES
7/28/2017 ARE REQUIRED PLEASE S
ECIFY EACH AREA FOR CONCRETE PSI CONCRETE SLAB, GRADE BEAMS, AND
PILES. SEE SECTION 107
F THE 2014 FLORIDA BUILDING CODE
Comment: - PLEASE ADD THE CUBI
VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING
7/28/2017 THE SQUARE FOOT INFO
MATION. SEE CHAPTER 1 SECTION 107 OF'THE 2014 FLORIDA BUILDING CODE.
Comment: • PLEASE SHOW FLAME
PREAD INDEXAND SMOKE DEVELOPED INDEX FOR WALL AND CEILING FINISHES
7/28/2017 IN ACCORDANCE WITH S
CTION 302.9 OF THE 2014 FLORIDA RESIDENTIAL CODE
Comment: • PLEASE SHOW THE F
ME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS
7/28/2017 REQUIRED IN SECTION 3 2.10.OF
THE 2014 FLORIDA RESIDENTIAL CODE
Comment: GEOTECHNICAL REPORT
CALLS OUT 5000 PSI FOR THE PILES. PLANS CALLOUT 4000 PSI ON PAGE A3.1. C
7/28/2017 SECTION 107 OF THE 2014
FLORIDA BUILDING CODE
Comment: PILE CAPS ARE LOCATE
OUTSIDE OF SETBACKS. STRUCTURE MUST BE LOCATED WITHIN THE
7/28/2017 SETBACKS.
ZONING REVIEW INCOMPLETE Ly
is Galbraith 7/10/2017
7/10/2017 Comment: PLEASE PROVIDE COPY
F COMPLETE FDEP PERMIT.
Comment:
7/10/2017
Comment:
7/1012017
7/11/2017 Comment:
SURVEY IS INCOMPLETE
- PLEASE INDICATE THE
- SETBACK TO THE 2ND I
- PROPOSED FFE ON SU
TO BE ABLE TO DETERh
REQUIREMENT OF FDEP
FDEP REFERENCE MONI
THE ELEVATION ARE NO
SURVEY OR THE SITE PL
PLEASE BE AWARE THA
EXAMINER MIGHT HAVE
OPOSED FFE OF THE GARAGE.
)OR BALCONY.
EY IS NOT MATCHING WITH THE SUBMITTED FLOOD CERT.
E IF THE BOTTOM OF THE FIRST STRUCTURAL BEAM IS MEETING THE
E WILL NEED TO KNOW THE CONVERSION RATE FROM NGVD TO NAVD. THE
ENT SCHEDULE THAT PROVIDES THE MIN. ELEVATION IS STILL IN NGVD. ALL
REQUIRED TO BE IN NAVD. PLEASE INDICATE THE CONVERSION RATE ON THE
ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS
)DITIONAL COMMENTS.