HomeMy WebLinkAboutWindow & Door Shop DrawingsA window
Quantity - 3
CX15-2 LR
NOA - FL12496.1 window
NOA - FL17720.2 mull
U-factor: 0.79,
SHGC: 0.28,
VT: 0.29
B window
Quantity -1
CX15-3 LLR
NOA- FL12496.1 window
NOA- FL17720.2 mull
U-factor: 0.79,
SHGC: 0.28,
VT. 0.29
Specifications:
1) Windows are by Andersen windows and doors
2) Doors are by Andersen windows, Windoor inc.
3) Andersen and WinDoor units are to be White interior and exterior
4) Andersen Glass is to be Gray Monolithic HP Sun low E laminated impact glass
5) Windoor glass is to be Gray monolthic laminated impact glass
6) Hardware to be corrosion resistant seacoast hardware package on all windows and doors
7) White finish folding hardware on windows
8) White Signature hardware on WinDoor sliding doors
9) Estate Newbury hardware brushed nickel finish on Andersen swing and sliding doors
F window
Quantity - 1
CN145/FF US
NOA- FL12496.1 window
NOA- FL15905.3 transom
NOA- FL17720.2 mull
U-factor: 0.79,
SHGC: 0.28,
VT: 0.29
I I.
I
o
G window
Quantity - 1
CN145/FF US
NOA - FL12496.1 window
NOA- FL15905.3 transom
NOA- FL17720.2 mull
U-factor: 0.79,
SHGC: 0.28,
VT: 0.29
C window
Quantity - 2
CX15/AN281 US
NOA- FL12496.1 window
NOA- FL15727.4 transom
NOA - FL17720.2 mull
U-factor: 0.79,
SHGC: 0.28,
VT: 0.29
F1,1111
1,111-i
AN281
D window
Quantity - 2
CX 15-3 R/S
NOA - FL12496.1 window
NOA - FL15727.4 transom
NOA- FL17720.2 mull
U-factor: 0.79,
SHGC: 0.28,
VT: 0_29
+ - ------
I I'
I Ic
AN281 � Q
i� CX15
31 1/2 "unit
E window
Quantity -1
CX15-3 R/S
NOA- FL12496.1 window
NOA - FL15727.4 transom
NOA- FL17720.2 mull
U-factor: 0.79,
SHGC: 0.28,
VT: 0.29
All units are viewed from the exterior
H window
I window
J window
K window
L window
Quantity - 2
Quantity - 2
Quantity - 1
Quantity - 4
Quantity - 5
CW15 R
CW15 L
P4060 S
C15 L
C15 R
NOA - FL12496.1
NOA - FL12496.1
NOA - FL15905.7
NOA - FL12496.1
NOA - FL12496.1
U-factor:0.79,
U-factor:0.79,
U-factor:0.81
U-factor:0.79,
U-factor:0.79,
SHGC: 0.28,
SHGC: 0.28,
SHGC: 0.31
SHGC: 0.28,
SHGC: 0.28,
VT. 0.29
VT 0.29
VT: 0.25
VT: 0.29
VT: 0.29
I'M
----------------,
III P4050
I
48 °unit _
rn
0
v'
Cq
d,oUu-
3N CIO
Go
ui X E o0
aw moo
� cc
_ 0.OM (DL)
H LL C%j
e
0
d
0 00 204 7•
�WLon
Z
J CL Q
Z n 0 M
r-
04 a
N
Z � �
C
0=�
0-
-0
J
0 LL LL
cZcc
U LO
�00
CIO
ICU
U
DRAW N
KCc3
CHE:CKn.r�
SHELT
Medina Lot # 50 Watersong, St Lucie County A2
of 6 SHEETS
M window
N window
Quantity -1
Quantity -1
CN14L
CN14R
NOA - FL12496.1
NOA - FL12496.1
U-factor: 0.79,
U-factor: 0.79,
SHGC: 0.28,
SHGC: 0.28,
VT 0.29
VT 0.29
I
O
\
O
I
u� of IL//CN1J4
LO
If IfI
I
II
L
.1j
20 1/2_unit
u MO
I
J
11
sII
I
All units are viewed from the exterior
# 1 door
Quantity - 1
FWOD2980 AL
NOA - FL14285.3
U-factor: 0.66
SHGC: 0.22
VT 0.17
O window
Quantity - 1
CW13 R
NOA - FL12496.1
U-factor: 0.79,
SHGC: 0.28,
VT 0.29
It 5 door/transom
Quantity -1
FWOD5480 APLR
custom circle top 54
NOA- FL14285.3 door
NOA- FL15954.1 transom
NOA- FL15119.1 mull
U-factor:0.66 �\
SHGC: 0.22 \�
VT 0.17 `
I I�
P window
Quantity - 1
CX16 R
NOA- FL12496.1
U-factor: 0.79,
SHGC: 0.28,
VT 0.29
\f
0154
-------- unit -- -------
I� Active/Passive
I cn
I
I
I
I
I
I
I
I
I
I �
I
I =
I a
I
I
# 3 door
Quantity -1
FWOD6080 APLR
NOA- FL14285.3
U-factor: 0.66
SHGC: 0.22
VT 0.17
------------------------
I
,
i
\
\
�
I
I
I
I
�
I
�
_
I
I
I
,
I
I
•
,
I
,
I
71 1/4 "unit
" Active/Passive
Medina Lot # 50 Watersong, St Lucie Coun
rn
0
M
W C!
a,caULL
N
O N C C
Ca m Co
W X b
°
N a w @p ao
m ccQa.c4
E
�
O cM O�
O CDLO
U-
�- N
N
0 00 LO V- N •
CO Z
.� . ��
so
V
K .✓ :ri
ai `� Q
7 C X
z a
N
Z � �
C)
Od
.0 M
J
LL U-
C Z
U ,L
a00
4-9
CD
M
0
U
DRAWN
3/4'- — 12"
JOS NO
SHEET
A
OF 6 SHEETS
Andersen hinge door details
ied Floor
concrete floor
EXTERIOR
# 4, 6 door details
- - - - - - - - - - - - - - - - -
1
�-----------------------:'
# 2 door details
r---------------------------- -----
�'==-------------------------------==��
m
Ljj
AWULL
04
O N
L m Co
�aLLI ia000
m ccQa.CO
E ° , is
O O M N LO
HLLN3:•=
C � CO
�
v- N •
N
� `v, Z
J d N v
z -3 G ,
a
N
Z
C
C
D1
N
dam'
0 _jJ
mI ILL
CO) m
U0U)
00
U)
c0
O
U
DRAWN
KCO
CHECKED
3/4•• - 12"
JOB NO
SHEET
A5
Medina Lot # 50 Watersong, St Lucie County
OF 6 SFTEETS
1..
31„ 24"
8„ 15" 2 8 Gn
J"Ox3" BLUE TAPCON J"Ox24" BLUE TAPCON B 4 CD
ANCHOR WITH 1 ANCHOR WITH 1}" 1. FIRST COA 5 WET MILS VULKEM 350 NF W � M
• MINIMUM EMBEDMENT ° MINIMUM EMBEDMENT ° = M
STAGGERED ° p �� 1„ STAGGERED p ep ° iV 2. CAULK BUCK U R AND AT FACE WITH VULKEM 116 d
N" 4 SHIMS ° 2" 4" SHIMS 3. PRIME BUCK OR ST L WITH TREMCO PRIMER N to V
VULKEM 350 NF (2 COATS) 6° 4. APPLY SECOND COAT 1 5 WET MILS TO MASONRY AND BUCK E Lo 0) (3
TYP. MASONRY WALL 3" 1j" TYP. MASONRY WALL ° }4" 18" SILICA AGGREGATE O N C R3
(NOT IN BUCK AREA) 5. APPLY SUCA AGGREGATE EXTERIOR PERIMETER. (NOT BUCK) fa Q 00
° 2X WOOD F- V m CV
° BU Lu x E co
0 ° � 0 ° yaW -a co
w . ° w p ° A) fQ W Q d T
z ° ° °„ BUCKING SEC C
�nm F- LL N e=
14 ne w e ° p
x p x ° °� INTERI
La° 4 w ° (BY 0 ERS)
a °
n ° a CANT BEAD VULKEM 116
AT ALL VERTICAL TO ° °� C
a J"Ox4" BLUE TAPCON Q p° ° HORIZONTAL TRANSITIONS CO
J"Ox5" BLUE TAPCON � T- cV
ANCHOR WITH 1 2X OD BUCK ANCHOR WITH 1j" ° 1X WOOD a W I R
MINIMUM EMBEDMENT EXTERIOR WALL ° = fh �O Z
MINIMUM EMBEDMENT BUCK � ti �
p° 0 (BY OTHER) LL -
SEALANT ° SEALANT
TYPICAL WALL ANCHORING TYPICAL WALL ANCHORING (BYOTHERS)
RE LATHn = C x Q
A D .� a rU . .
(2) 2X BUCKING ATTACH TO MASONRY WALL 1X AND 2X BUCKING ATTACH TO MASONRY WALL Z = a
STUCCO
a
3 (2) 2X WOOD BUCK
11 " J"0x2j" BLUE TAPCON (BY OTHERS) N
TYP. MASONRY WALL H 1" 1" 4" SHIMS ANCHOR WITH 1j" G TYPICAL WATERPROOFING
MINIMUM EMBEDMENT 4" WINDOW WATERPROOFING
J"00" BLUE TAPCON FROM END AND 12" C.C. �" 18" SHIMS —
ANCHOR WITH 1j" STAGGERED m
MINIMUM EMBEDMENT 4" ° p,
• FROM ENDS AND 12" C.C. TYP. MASONRY WALL ° 7
STAGGERED p N a �7
° 14„ � 11„ �� m
L
• r 4 N 0
> z p z
iO w
O OFE
I U
w 1„ 1 w
a
w , 48 A� x3w ° 14 • • V
° N p 2p (2 1X � C
J"0x5" BLUE TAPCON"0�" BLUE TAPCON OD BUCK
ANCHOR WITH 1j" MINIMUM p ° ANCHOR WITH 1j" p0 C
EMBEDMENT 6" AND 16" C.C. MINIMUM EMBEDMENT 6" o
STAGGERED
SEALANT FROM ENDS AND 16" C.C. IN°(n
SEALANT D �.
B TYPICAL WALL ANCHORING E TYPICAL WALL ANCHORING °le 1
(2) 2X BUCKING ATTACH TO MASONRY WALL (2)1X BUCKING ATTACH TO MASONRY WALL • • d'
C N cM
SHIMS 1„ Z„ 4„ SHIMS � O
TYP. MASONRY WALL 5 TYP. MASONRY WALL 8 8 u-
p> 1$ • Al
° ° p C Z J
n
n
� Uo DOUBLE ROW U C 0)
Lo
28^ N (TYPICAL)
` OF ANCHORS
uj z ° N� z p 100
° 3° 14
O p =IN O ° -IN
ER w w ° •—��• O
x 414" x
w ° w ° NOTE: U
p
p J"Ox2j" BLUE TAPCON p ° SPACING SHOWN IS MAXIMUM. 0O DKCor'
"0x3" BLUE TAPCON 2X WOOD ANCHOR WITH 1 REFER TO ANCHORING DETAIL LL o_ ctxx;cxcjMn
ANCHOR WITH 1j" . BUCK MINIMUM EMBEDMENT 6" ° SHEETS FOR SPECIFIC SPACING. w xcc3
d MINIMUM EMBEDMENT 6" FROM END AND 16" C.C. ALTER LOCATION AS REQUIRED 61 o sizz
FROM END AND 16" C.C. TO MAINTAIN A 3" C.C.
w 3 a••�- yam..
SEALANT ANCHOR SPACING MINIMUM
� SEALANT sos xvo
` C TYPICAL WALLANCHORING c TYPICAL WALL ANCHORING TYPICAL FRONT VIEW SHEET
N 2x BUCKING ATTACH TO MASONRY WALL 1X BUCKING ATTACH TO MASONRY WALL TYPICAL JAMB ANCHORING PATTERN A6
OF 6 577P.ET5