Loading...
HomeMy WebLinkAboutRevisionOFFICE USE ONLY: DATE FILED: REVISION FEE: PERMIT#>3 C6�S RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5662 (772) 462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 8208 s ocean drive jesen beach DETAILED DESCRIPTION OF PROJECT REVISIONS: changed the spa from a champagne spa to a regular raised spa, changed from a gas heater to a heat pump CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: cpc 1457120 BUSINESS NAME: CRYSTAL POOLS QUALIFIERS NAME: BARRY MILLS ADDRESS: 4680 US1 CITY: VERO BEACH STATE: FL PHONE (DAYTIME): 567-3067 OWNER/BUILDER INFORMATION: NAME: LABARBIERA ADDRESS:8208 S OCEAN DR CITY: Jensen beach PHONE (DAYTIME: STATE: tt ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9123109 Revised 06130/17 N1Alb: ST. LUCIE CO CERT. #: FAX: CMNNII FAX: IF419 ZIP: 34957 ZIP: DocuSign Envelope to: FB3B7E91-0254-4FC3-AB4A-19957AAEOE95 ti ,.�. " F,', C m J _ ¢ 1. VE Q:. 'I, n1 .G,H . ! .��i°3�t R.,'f` • ^� 15 April 2022 Phoenix Custom Homes 1760 Jog Road, Suite 120 West Palm Beach, FL 33411 Subject: Addendum to Report of Geotechnical Services - Proposed Pool 8208 South Ocean Drive, Diamond Sands Lot 31 Jensen Beach, Florida Ailterre Engineering & Testing respectfully submits this addendum to its report of geotechnical services for the subject project dated 1 March 2021. This addendum adds pile recommendations for the swimming -pool. This addendum is Aliterra's instrument -of - service provided for sole reliance and use by Phoenix Custom Homes. Third parties may read this report for information purposes. A digital copy of a memorandum dated March 22, 2022, and entitled Design Wave Condition, 8208 S. Ocean Drive, Jensen Beach, St. Lucie County, Florida by isiminger & Stubbs Engineering was provided for Ailterra's refence in performing its services. The memorandum presented information on design eroded -grade elevation, breaking wave crest elevation, still water elevation, wave and debris impact forces on square and round piles, and hydrodynamic wave forces Aiiterra applied the memorandum's information and conceptual subsurface profile from the 1 March 2021 geotechnicai services report to its design model. Aliterra estimated the following capacities for 14-inch and 16-inch auger -cast piles installed to approximately 26 feet below surface grade (approximately 18 feet below scour grade). Existing ground surface elevation is +7.5 NAVD, with the head of the pile at elevation +16 and the toe at elevation -19, 14 t-ULTIMATE= ultimate compressive load capacity. Cauownai.E = allowable compressive load capacity. CUtT1CuLow = CULnMATE / C'AILOWPaLE Uplift Resistance = (weight of pile + skin friction)/1.5. Kips = 1000 pounds. 2.1 110 Considering the breaking wave crest elevation of +15.5 feet NAVD and FF elevation from site plans, Aliterre assumed a low structural floor beam at +16 feet NAVD (approximately 17 feet above eroded grade). The usage of piles on a 15` batter will reduce lateral deflections. Model lateral displacements for fixed -toe fixed -head piles installed to approximately 26 feet below surface grade (appro)imately 18 feet below scour grade) are summarized in following table: Addendum to Geotachnical Services 15 April 2022 1 8208 South Ocean Drive, Jensen Beach, FL 21-179 DocuSign Envelope IDS FB3B7E91-0254-4FG3-AB4A-19957AAEOE95 For auger -cast piles, Allterra recommends: Pile Materials. Piles shall be formed with minimum 4000 PSI grout placed under pressure as the auger is progressively withdrawn from the borehole. Piles (14-inch diameter) shall be reinforced with five full -depth number-5 steel bars and number-3 ties spaced not more than 16 inches on -center. Piles (16-inch diameter) shall be reinforced with seven full -depth number-5 steel bars and number-3 ties spaced not more than 16 inches on -center. The structural engineer shall determine the number and distribution of piles considering structural loads and geometry. Pile Layout. The number and distribution of piles shall be determined by the structural engineer considering project loads and geometry. Piles shall be spaced at -least 3 diameters center -to -center to avoid group effect on stress distribution in the bearing stratum. Pile -Installation Monitoring. Engage Allterre to monitor installation of piles. For auger -cast piles, monitoring shall include: 1. Check pile layout for conformance to design foundation plan. 2. Observe field trial and calculate gout -pump factor. 3. Observe drilling of pile to verify target depths are achieved. 4. Observe grouting of pile bore to verify acceptable grout return. 5. Sample grout for compressive -strength testing. 6. Observe installation of reinforcing steel to verify full -depth penetration. 7. Test grout specimens to verify design compressive strength is achieved. 8. Calculate grout factors and summarize installation data for each pile. 9. Prepare report of work acceptance signed and sealed by Professional Engineer. Please call the undersigned if one has questions about this report or needs other services. Yours truly, ANEW jy''•,, Ailterra Engineering 4.lt 1cENSF""�Tj FBPE Registry No. 9139: /D..8819..d•,by: I'' No, 81271 —EM2552F31748A._ Matthew Watts, PE k1 Q STATE OF ( -�. Senior Engineer FL �` F >'OR1DP..' ' Lic. No. 81271 SS C> ; 11y/y IONA>_'E � C: Rob Agsten, PE Addendum to Geotechnicel Services 2 15 April 2022 This item has been digitally signed and sealed by Matthew Watts, PE on the date adjacent to the seat. Printed copies of this document are not considered signed and sealed and the signature must be verified on electronic copies. 8206 South Ocean Dnve, Jensen Beach, FL 21- 179 r • II31"MIMOILMNIM I I, DETAILS - BY OTHERS Iffieffm EXISTING 48" MIN. HIGH FENCE W/ SELF LATCHING GATE THAT SWINGS OUT AWAY FROM POOL AREA VERIFY EXIST. FENCE IN COMPLIANCE W/ CHILD SAFETY BARRIER REQUIREMENTS PER FBC SEVENTH EDITION (2020) POOL/SPA HEATER UNDER STAIRS SEE SITE PLAN: BY OTHERS w REINFORCED OR PRODUCT APPROVED CONCRETE. SLAB(S) (FIELD VERIFY SIZE & LOCATION) I AUTO -FILL DEVICE 3/4 FRESH WATER R SUPPLY LINE FROM EX. HOSE BIBS BY OTHERS FIELD VERIFY I B. LOC. & 2" OVERFLOW LINE TO ON SITE DRAINAGE SYSTEM - BY OTHERS 1`1 1mm7p 1i".►ty�nl 21 Ni 1 r 1 11 "T.X1161111 . '.:...'' Oita Ava p Iola11111TWIVIII relolvawI IN1101411 LWIT111111 # t VERIFIED W/ OWNER PRIOR TO CONSTRUCTION POOL/SPA EQUIP. IN BASEMENT (GROUND LEVEL) SEE SITE PLAN: BY OTHERS I - 7TTTT�' I i Ilv a M SKIMMER STEPS - 240 SQ. IN. NILN. TOPTREAD 12° (2)LED 12d LIGH'S'S 18" W/ NICHE STUB -OUT FOR POOL CLEANER I 112"1 12" 12" 2LW I� I L — — — — — � " SC! 2.5" SCH 40 — — — 3H 41 PERIMETER BONDING / WIRE @ 18"MLV. - 24" MAX. 07 FROM W.L. (SEE DETAIL) DECK -BY ()TIERS �.. FINISH FLOOR ELEVATION = 21.5' NAYD AQUASTAR 32CDFL - 32" CHANNEL DRAIN (316 GPM @3.9 FT/SEC THRU GRATE - SINGLE UNBLOCKABLE COMPLIANT W/ ASME/ANSI All 2.19A - 2017 OR EQUAL: if SCH 40 I — —. 2.5" SC2H 40 40� I L �3" SCIL 40 J 1.5" SCH 40 MANIFOLD r (4) INLETS PROVIDE WINDOW AND DOOR ALARMS ON ALL OPENINGS THAT LEAD ONTO POOL AREA PER CODE 6 12" RAISED SPA. � a1 18" RENCH • 18" & 24" BELOW W.L. ti (6) THERAPY JETS (1) AQUASTAR 32CDFL - 32" CHANNEL ®R DRAIN (316 GPM @ 3.9 FT/SEC THRU GRATE- SINGLE. UNBLOCKABLE ! OR EQUAL. R (1) LED SPA LIST - NICHELESS 24" SPILLWAY REMOTE SPA CONTROL R 9 POOL/SPA PLUMBING . SCALE: 1/4 1r_®er NOTE: THESE PLANS ARE FOR POOL AND SPA STRUCTURES, PLUMBING EQUIPMENT/ELECTRICAL ONLY. ALL OTHER FEATURES DESIGNED BY OTHERS. i 0 STAIRS & / RAILING — BY OTHERS EXIST. PORCH 8tt RAILING — BY OTHERS 81f I", be fl➢ F 14" DIA. AUGER CAST PILL, PILE TO BE PLACED ON 15 8" THICK DEGREE ANGLE OUTWARD (9 REQUIRED) : POOL FROM BOTTOM OF POOL 15 TON DESIGN CAPACITY WALLS 30 TON DESIGN CAPACITY SHELL —TYP. 5 PLACES41 SHOWN — — — — — — — — —__..--.-._.— -------------- ----.— i i12"THICK-----�-- POOL I I �,! FLOOR I I I 8° 2°-8° P t o I I I 13' "' 1 99 1 8„ 8„ d`"I 2„ I I 8°-4 lz" „ I THICK "t I I I I SPA WALLS I I I I I 4° I - ---- — — -- —-- 2" p 12" 8" 12" THICK L — ---- -- ---- SPAF'LOOR 21.0' NA 51-2,° 61-2" _ 24" 51-2" 61 15, J--- 1.2t-811 RUN IT® RESIDENCE FINISH FLOOR ELEVATION = 21.5' NAVD 1.1'-10" . - is LA"VOUT & PILING PLAN. COPING - TYP. TILE OR STUCCO FINISH - P / #4 DIA. REBAR Ca, 5„ DECK - BY OTHERS 1II„ O.C.E.W. IN SPA WALL W.L. � 12„ W.L. 12" � 18" 6" #4 DIA. REBAR 11211 DECK AND DECK POOL/SPA @ 6" O.C.E.W. BEAM JOINT WATERPROOFING TOP MAT SPECIFICATIONS AND DETAILS - BY OTHERS 1299 18" DIA. - 5000 P.S.I. CONCRETE 12't - , ,� EXTENSION TYP. 2" 14" DIA. AUGER CAST PILE - TYP. 15 TON DESIGN CAPACITY 30 TON ULTIMATE CAPACITY #4 DIA. REBAR O.C.E.W.MA SECTION BSPA. BOTT TOM MAT SCALE: 3/8" = F-0" I 1 181,( °-41i CONTROL, LINES - FIELD VERIFY 911 PW IN AND POOL ELEVATION PRIOR TO POOL LAYOUT1 DIMENSIONS CONTROL —"" LINES —FIELD VERIFY RAILING - 8„ BY OTHERS NOTE: APPLY BASECRETE WATER PROOFING ON ENTIRE POOL/SPA WET SURFACE PER MANUFACTURES SPECIFICATIONS PRIOR TO INSTALLATION OF ALL FINISHES NOTE - DECK AND DECK POOL/SPA BEAM JOINT WATERPROOFING SPECIFICATIONS AND DETAILS - BY OTHERS 14" PROVIDE 3" MIN. CONCRETE COVER ON REBAR 14" DIA. AUGER CAST PILE - 5000 PSI CONCRETE - TYP. W/ A CAGE OF (5) #7 DIA. REAR VERTICAL FULL DEPTH OF PILE W/ #3 DIA. REBAR TIES @ 12" O.C. ESTIMATED LENGTH IS +/- 30 FEET - BOTTOM OF PILE TO BE AT -20.0' NAVD. PILE CAPACITY SIIALL BE 30 TONS (60 KIPS) SEE SOIL REPORT BY ALLTERRA ENGINEERING A WATERLINE �r 24" MIN. BEND INTO � TOP MAT - TYP. BEND 18"STANDARD 18" DIA. - 5000 P.S.I. CONCRETE � EXTENSION fl II " �,]t®dltt JJM flED/X. #3 DIA. HOOPS II L 12" O.C. 2„ 36" LAP SPLICE - TYP. Zn I I t MIN. PILING PILE STEEL 'PIED INTO BOTTOM MAT OF POOL I Alf FLOOR STEEL � PILE EXTENSION DETA114 SCALE: 3/8" = V - 0" - - #3 DIA. REBAR TIES (a,12" O.C. - (5) #7 DIA. CONT. VERTICAL REBAR — 18" DIA. - 5000 P.S.I. CONCRETE EXTENSION - SEE PILE EXTENSION DETAIL L_._j ELEV. -20.0' NAVD 14" DIA. AUGERCAST CONCRETE PILE DETAIL SCALE: 3/8" = V-a'° COPING - TYP. DECK - BY OTHERS \ DECK AND DECK POOL/SPA BEAM JOINT WATERPROOFING SPECIFICATIONS AND DETAILS - BY OTHERS " it 1 18" DIA. PILE PILING NOTES.- EXTENSION - SEE DETAIL _ 5" KN -RECESS PILING 3" INTO #4 DIA. REBAR @ BOTTOM OF POOL FLOOR 12" O.C.E.W. (TYP.) BOTTOM MAT -PILE REINFORCING (NOT SHOWN) IS TO BE SPECIFIED BY PILING ENGINEER - PILING STEEL TO BE BENT INTO POOL FLOOR AND TIED TO 14" DIA. AUGER CAST PILE - TYP. TOP TIMAT OF STEEL 15 TON DESIGN CAPACITY 30 TON ULTIMATE CAPACITY 23' 12"112"112" E 81t COPING - TYP. lilt —"1 54t r lot, 1 Olt loot 129 \ )#4 DIA. REBAR @ 12" O.C.E.W. BOTTOM MAT STEP SECTIONI SCALE: 3/8" = P-0" mi WATERLINE #4 DIA. REBAR (q; 6t' O.C.E.W. TOP MAT 10.41' SLOPE It 1.8" DIA. PILE 18" DIA. PILE EXTENSION - EXTENSION - SEE DETAIL SEE DETAIL TYPE "0" POOL SCALE: 3/8" = 1'-0" — DECK -BY OTHERS DECK AND DECK POOL/SPA BEAM JOINT WATERPROOFING SPECIFICATIONS AND DETAILS - BY OTHERS #4 DIA. REBAR @ 12" O.C.E.W. BOTTOM MAT - 18" DIA. PILE EXTENSION - SEE DETAIL 14" DIA. AUGER CAST PILE - TYP. 15 TON DESIGN CAPACITY 30 TON ULTIMATE CAPACITY 91 COPING - TYP I 1, STUCCO FINISH AY�OTHERS h #4 DIA. REBAR � 12" O.C.E.W. WALL - BY OTHERS 1p i I DECK - BY OTHERS STONE COPINC 8" ..... -V--V-. OR EQUAL SLOPE DECK @ UAL --� I i Y," PER. FOOT 5" .%ocf - 2 - #4 DIA. COST. MARCITE OR EQUAL EINFOI1 (SEE SHE 12" RADRUS VARIES TYPICAL WALL SECTION WATER LINE Asa VACUUM FITTING W/ SELF -CLOSING SAFETY COVER (HAYWARD MODEL #400 OR EQUAL) VACUUM LINE DETAIL OVREN APPLICABLE) W.L. #8 SOLID BARE COPPER BOND WIRE W1 APPIL CLAMPS (ONE ON EACH SIDE OF POOL-4TOTAL) POOL SYSTEM FLOW RATE- 150 GPM (MAXIMUM FLOW FROM PUMP CURVE) REC. PUMP = 2.7 HP JANDY VS -Plus HP VSPHP270 VARIABLE SPEED - LOW SPEED = 36 GPM MAX. HIGH SPEED = 150 GPM (&�� 50 TDH 3" SUCTION PIPE g 150 GPM = 6.63 FT./SEC. (8 FT./SEC. MAX. - SUCTION LINES) 2.5" BRANCH PIPE g 75 GPM= 5.13 FT./SEC. (6 FT./SEC. MAX. - SUCTION LINES) - 3" PRESSURE PIPE * 150 GPM = 6.63 FT./SEC. (10 FT./SEC. MAX. - PRESSURE LINES) CARTRIDGE FILTER = 150 GPM @ I GPM] SQ. FT. = 150 SQ. FT. MIN. FILTER AREA 18"IN.24 X. A (ENTIREPE RTWEER) tj 6" THICK CONCRETE SLAB (BY OTHERS) W/ (1) #8 BARE SOLID COPPER WIRE BONDED TO POOL STEEL AS SHOWN KOUIPOTENTIAL BONDING DETAIL PER FLORIDA BUILDING CODE ADAPTATION Ok N.F.C.2017SEC. 680.26 14tv o CONTROUPOOL PANEL W/ 60 AMP, 2 POLL BREAKER AVI INTEGRAL PIPE REDUCED TO V TIME CLOCK FOR PUMPS, MOTOR AND RUN TO DECK AND HEATER (2) - #6 LINE, (1) #6 NEU. & (1) #]BEQUIPMENT GROUNDING CONDUCTOR THICIN, CU IN I" RPVCCONDUIT(MAX.210FT) S,P.S,T . TIOGGLE 2' SCH 40 PVC CORD swi LCH LED LIGHT SLEEVE (2) LED POOL LIGIITS,�� SP 10-22 WALL FITTING-OREQUAL (GET NOTREQLIRFD � INSTALLED INSIDE PIPE (1) LED SPA LIGHT AV ( GET NOT REQUIRED) EQUIPMENT LAYOUT SCALE: N.T.S. 11"Mfiff LEGEND 1. 3" SPA MAIN DRAIN LINE 2. 2" VACUUM LINE 3. 3" POOL MAIN DRAIN LINE G) 4. 2" SKIMMER LINE 5. 3" RETURN TO SPA THERAPY JETS 6. 3" POOL RETURN LINE HEATPUMP/CHILLER W/ (2) #6 CU, (1) #10 NEUT. & (1) #10 CU GROUND IN 3/4" CONDUIT (CONNECT TO 50 AMP-2 POLE BREAKER) MANUAL MOTOR STARTER SWITCH 2.7 HE PUMP MOTOR w/ BUILT-IN OVERLOAD SWITCH NV/ 3 - #I 0THHN CU Vi'ITHIN 1/2" MIN. CONDIJIT (CONNECT TOP 20 AMP - 2 POLE GFCI BREAKER) Z-�-12 VOLT TRANSFORMER JUNCTION BOX 1. ALL ELECTRICAL TO COMPLY WITH NEC 2017, SECTION 680, ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION. 2. 3412TIHIN CU WITHIN 1/2" MIN. CONDUIT FOR POOL LIGHT(S). 3. GROUND ALI, BOXES, LIGHTS, MOTORS, ETC. w/ #8 SOLID. BARE COPPER. 4. PROVIDE W.P,G.F.I. OUTLET 10'MIN. - 20'MAX. FROM WATER'S EDGE. 5. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.5. 6. LOAD CALCULATIONS FOR EXISTING SERVICE AND PANEL - BY OTHERS. 7. ALL PVC CONDUITS EXPOSED TO SUNLIGHT TO BE PAINTED WITH APPROVED COATING. ELECTRICAL DIAGRAM NA%S. AQUASTAR 32CDFL - 32" CHANNEL DRAIN(316 GPM @� 3.9 FT/SEC THRU GRATE - SINGLE UNBLOCKABLE OR EQUAL �73 FINISH PLASTER _ T: HYDROSTATIC RELIEF VALVE & PERFORATED PVC COLLECTION TUBE, WHERE REQUIRED A. 2.7 HP REC./THERAPY PUMP W/ APPR. HAIR & LINT STRAINER B. CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE C. 1.5" TO WASTE OR DISCHARGE TO GROUND D. 132,000 BTU HEAT PUMP/CHILLER W/ INTERNAL BY-PASS E. VALVES (TYPICAL) F. SALT GENERATOR G. INSTALL PERMA-CAST PB-2011 WATER BONDI OR APPROVED EQUAL TIED TO PUMP GROUND W/ #8 SOLID COPPER & APPROVED LUG (MIN. 9 SQ. IN SURFACE AREA EXPOSED TO WATER) PER MFGRvS SPECS (FIELD VERIFY LOCATION) 33/321, HYDROSTATIC RELIEF VALVE PORT OR CAP OFF MAIN DRAIN SUCTION LINE TIED TOGETHER AS SHOWN ABOVE - PIPE SIZE PER PLAN MIN. Y2 YARD GRAVEL SUMP NOTE: 25.9 SQUARE INCH OPEN AREA, WRAPPED W/ DRAIN FEILD 316 GPM = 3.9 FEET PER SICCOND CLOTH (RECOMMENDED) Channel Main Drain Detail SCALE: 318" = V-0" PUMP FRAME OR FILTER TANK MOUNT OR HEATER ANCHOR POOL PUMP AND FILTER PER MFGR'S N.O.A. ­ 7 " 4" THICK REINFORCED CONCRETE SLAB 2" MIN. F.G. DYTISD 11111111 POOL PIMP, FILTER '- AND HEATER ANCHOR POINTSMAY VARY HEATER tP09901, E QU[I'MIENTANCHORING DETAIL _ SEE MIGIL SPECIFICATIONS FOR ADDITIONALANCHORING INFORMATION - EQUIPMENT SHAPES MAY VARY POOL SIZE: 13'-0" X 28'-0" DEPTH: Y-0" TO 4'-11" SPA SIZE: 6'-2" X 8' 4" DEPTH: Y-0" COMBINED VOLUME: jl_.,200 GALLONS POOL ELEVATION: TOP OF COPING = 21.0'NTAVD TURN OVER RATE: 5.1 HR. M MAX� LOW SPEED m �36 GP��� (TURN OVER RATE: 1.2 HR.,-& 150 GPM - HIGH SPEED) DESIGN FLOW RATE = 11 ' 200 GALJ6 HRS./60 MIN. = 32 G.P.M. TILE: STANDARD THERAPY JETS: J41IN SPA POOL/SPA -FINISH. MARCITE OR EQUAL PIPING: SCH. 40 INLETS: POQj.j4jSPA _(jjjRK JETS) DECK: BY OTHERS ELECTRIC: BY OTHERS POOL LICTIT-1-2) JANDY LED - N�1CMT4LESS *0 wy a rN r. MI fq M A A, will W.42 CIILORINE JENERATOR: JANDY POOL/SPA cj)NTROL SYSTEM: JANDY I- GENERAL NOTES: 1. ALL LIGHTS, LADDERS, HANDRAILS, REINFORCING STEEL SHALL BE GROUNDED PER CODE. 2. POOL TO BE CONSTRUCTEI) OFCONCRFTE/GUNITE WITH A MINIMUM COMPRESSIVE STRENGTH OF3000 P.S.I. AT 28 DAYS. 3. ALI, REINFORCING STEEL, SHALL BE INTERMEDIATE GRADE DEFORMED BARS OF NEW BILLET STEEL, CONFORMINGTO AS TM A-615, GRADE 60, STEEL SHALL STANDARDS. PROVIDE, 3" MIN. CONCRETE' COVER OVEIR REINFORCING STEFL.. 4. GRATICINMAIN DRAIN SHALL HAVE A FREE AREA OF 4TIMES THEI ARICA OF THE SUCTION LINE. 5. STEPS TO HAVE A 10" MINIMUM TREAD AND A 12" MAXIMUM RISER. 6. POOL TO BE FENCED PER LOCAL CODES. 7, GATSTO 13E SELF -LATCHING, NELF-<A,OSING AND LOCKABLE 8. DESIGN, CONSTRUCTION AND WORKMANSHIP SHALL BIC INCONFORMITY WITH THE CURRENT REQUIREMENTS OF ANSI/ NSPI 3; ANSUNSPI 4; ANSI/ NSPI S;ANSU NSPI 6; AND ANSI/APSP 7 AND ANSIIAPSP.ICC-15, 9. SPAS AND HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A COVER DESIGNED TO MINIMIZE HEAT LOSS. EXCEPTIONS: OUTDOOR POOLS DERIVING OVER 70 PERCENTOF THE ENERGY FOR HEATING FROM NON-DEPLETABLE ON -SITE RECOVERED SOURCES COMPUTED OVER AN OPERATING SEASON ARE EXEMPT FROM THIS REQUIREMENT. 10. ALL FEATURES OF THE POOL/SPA SHALL BE INSTALLED IN COMPLIANCE WITH THE FBC SEVENTH EDITION (2020) - RESIDENTIAL -PRIVATE SWIMMING POOL AND LOCAL AMENDMENTS, IF ANY. 11. RESIDENTIAL SWIMMING POOL BARRIER SHALL COMPLY WITH FBC SEVENTH EDITION (2020) - RESIDENTIAL CHAPTER 45 - PRIVATE SWIMMING POOL. 12. SHOULD ANY MUCK, MARL, OR OTHER ORGANIC SOILS BE DISCOVERED ON EXCAVATION, THEY SHOULD BE REMOVED IN THEIR ENTIRETY, ALI, CONSTRUCTION SHALL STOP AND THE ENGINEER OF RECORD SHALL BE CONTACTED TO CONDUCT AN INSPECTION. 13, POOL CONTRACTOR/OWNER BUILDERS TO VERIFY ALL POOL DIMENSIONS, POOL LOCATION AND SETBACKS PRIOR TO CONSTRUCTION. (CONTACT ENGINEER IF ANY DISCREPANCIES OCCUR) 14. POOL PLANS ARE DESIGNED TO MEET THE FBC SEVENTH EDITION (2020) - RESIDENTIAL- PRIVATE SWIMMING POOLS. 15. ENTRAPMENT PROTECTION FOR SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ANSVAPSP 7-2006 AND FBC SEVENTH EDITION (2020) - RESIDENTIAL CHAPTER 45. 16. GROUND WATER MUST BE LOWERED TO BOTTOM OF DEEP END PRIOR TO EMPTYING POOL TO AVOID UPLIFTING (POPPING) OF POOL. PLUMBING MOTES- L ALL PIPING, EQUIPMENT AND MATERIALS USED IN' THE PLUJIVIBING SYSTEM Of SWIMMING POOLSTUATARIC BCILTIN PLACE SHALL CONFORM TOTDR FBC Sl,',VFN'FH EDITION (2020), PLUMBING, CHAPTER 45 - PRIVATE SWIMMING POOLS. L POOL PIPING SHALL BE DESIGNED SOTHE WATER VELOCITY WILL NOT EXCEED 6 FT/SEC ON BRANCH SUCTION LINES, 8 FT/SEC. ON SUCTION LINES AND 10 FT/SEC. PRESSURE LINES, 3. VALVES SHALL BE MADE OF MATERIALS THAT ARE APPROVED IN THE FLORIDA BUILDING CODE, PLUMBING. VALVES LOCATED UNDER CONCRETE SLABS SHALL BE SET IN A PIT HAVING ATLEAST A DIMENSION OF FIVE DIAMETERS WITH A MINIMUM OF AT LEAST 10 INCHES AND FITTED WITH A SUITABLE COVER. ALI., VALVES SHALL BE LOCATED WHERETHEY WILL HE READILY ACCESSIBLE FOR MAINTENANCE AND REMOVAL, 4. WHERE CHECK VALVES ARE INSTALLED, THEY SHALL HE OF THE SWING OR VERTICAL CHECK PATTERN. 5. ALL HEATERS SHALL BE EQUIPPED WITH AN APPROVED PERMANENT BY-PASS OR ANTI -SIPHON DEVICE INSTALLED TO PROVIDE A POSITIVE MEANS OF RETAINING WATER IN THE HEATER WHEN THE PUMP IS NOT IN OPERATION. 6. ALL POOL PIPING SHALL BE 1.511 SCH. 40 PVC EXCEPT AS SHOWN AND SHALL BEAR THE H.S.P. SEAL OF APPROVAL. 7. THIS POOL/SPA IS DESIGNED TO WITHSTAND HYDROSTATIC UPLIFT FORCES WHEN EMPTY, FOR WATER TABLE UPTO Y-O" BELOW POOIJSPA DECK ELEVATION. HOWEVER, DUE TO SEASONAL, VARIATIONS IN THE WATERTABLE ELEVATIONS, ALI, POOL/SPA SHALL BE FITTED WITH A HYDROSTATIC RELIEF VALVE. 8. WATER SUPPLY AND DISPOSAL SI IALL BE ARRANGED SO THERE IS NO CROSS SUCTION WITH A DOMESTIC WATER SUPPLY OF WATER DiSPOSAL, 9. UNLESS AN APPROVED TYPE OF' FILLING SYSTEM IS INSTALLED, ANY WATER SUPPLY WHICH IN THE JUDGEMENT OF THE ADMINISTRATIVE AUTHORITY" MAY BE USED TO FILL THE POOL IF EQUIPPED WITH BACK FLOW PROTECTION. NO OVER -THE -RIM FILL SPOUT WILL BE ACCEPTED UNLESS LOCATED UNDER A DIVING BOARD, OR PROPERLY GUARDED. 10. ALL POCIL/SPA PIPING SHALL HE INSPECTED AND APPROVED BEFORE COVERING OR CONCEALING. IT SHALL BE TESTED AND PROVED TIGHT TO THE SATISFACTION OF THE ADMINISTRATIVE AUTHORITY, UNDER A STATIC WATER TEST OF NOT LESS THAN 50 PSI FOR 15 MINUTES. 11. JOINTS AND CONNECTIONS SHALL BE MADE AS REQUIRED BY THE FBC, SEVENTH EDITION (2020), PLUMBING REQUIREMENTS. 12. ALL WATER HEATING EQUIPMENT SHALL BE INSTALLED WITH FLANGES OR UNION CONNECTION ADJACENT, TOTHE HEATER. LU PURPLE PRIMER CONFORMING TO ASTM F656 REQUIRED ON ALI, PVC PIPING PER FBC SEVENTH EDITION (2020) PLUMBING 605.21.3. 14, GAS PIPING SHALL COMPLY WITH FBC, SEVENTH EDITION (2020), FUEL GAS. (SEPARATE PLANS AND PERMIT' REQUIRED) 15. SWIMMING POOL/SPA WATER HEATERS SHALL BEAR THE LABEL OF RECOGNIZEDTESTING AGENCY. 16. PROVIDE BACK FLOW PREVENTORON WATER SUPPLV - BY OTHERS. DRAWN BY: W11C CHECKED BY: Sms DATE. SCALE AS NOTED JOB NUMBER: 21-295