Loading...
HomeMy WebLinkAboutCertification For Design Load ComplianceRECEI\'_D OCT 17 Z017 Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FI- 34982 - (772) 462-1553 Certification for Design Load Compliance Project Name: Halbert residence Project Address: 4884 Watersong Way, Fort Pierce FL 34949 Permit #: Occupancy Type: R-3 Construction Type: -�-+ INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2 s 144 Code Fifth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as 711 ne): VEnclosed Partially Enclosed —Open 3. Risk Category: IIII IV Exposure Category: _B _C 4. Design Wind Velocity 170 mph ✓ASD _LRFD End Zone Width: . 0 ft S. Mean Roof Height 3 9 ft Roof Pitch: ? :12 Parapet: -p-o ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 4 9. % Zone 2: c% Zone 3: Z8 + Zone 4: Zone 5: G Z� 9 Garage: a� 7. Design Loads: Floor: �Ps�� hSF Roof/Dead: 2 5- PSF Roof/Live:_ Balcony: 40 mac- PSF Dock: PSF Deck: PSF Stairs: S PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? �es Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? 'Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2 *Go PSF Soil Test Reports Submitted? Yes Nei -fir : Pfc-( V-odNO bfIOtJ DESIGN PROFESSIONAL CERTIFICATION STATEMENT- I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. 1 also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: PE: 7-0 Wit .�`Ao-,:- B�s�Du-Se 4A -7 -7 v-Ls Si ture, Date, and Seal Revised 07/25/2014 Print Name ETA- s (3us(.ksee Cert # & Co. Cert Auth. .�N G 33m0 06 r,,rk re__^R tt-Z4- Company Name & Address 'ile Pt*;-%r'iw"V (ycacw I� L 33oG 4