Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeC R I FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HALBERT RESIDENCE Builder Name: Street: SITE 52 WATERSONG Permit Office: ST. LUCIE COUNTY City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (5191.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=20.0 5101.00 ft2 b. Frame - Wood, Adjacent R=19.0 90.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1887.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=22.0 1887.00 ft2 6. Conditioned floor area above grade (ft2) 4335 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= . ft2 11. Ducts R ft2 7. Windows(989.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 425 a. U-Factor: Dbl, U=0.79 613.00 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 325 SHGC: SHGC=0.28 b. U-Factor: Dbl, U=1.06 254.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.39 a. Central Unit 48.0 SEER:17.00 c. U-Factor: Dbl, U=1.06 80.00 ft2 b. Central Unit 36.0 SEER:17.50 SHGC: SHGC=0.30 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 42.00 ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: other (see details) b. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 4.407 ft. Area Weighted Average SHGC: 0.305 14. Hot water systems 8. Floor Types (18,86.5 sqft.) Insulation Area a. Electric Cap: 80 gallons a. Raised Floor R=19.0 1814.50 ft2 b. Conservation features EF: 0.950 b. Raised Floor R=0.0 72.00 ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.228 Total Proposed Modified Loads: 149.65 PASS Total Baseline Loads: 152.03 I hereby certify that the plans and specifications covered by Review of the plans and Srg?� this calculation are in compliance withtheFlorida Energy specifications covered by this o�TgE 1+ s Off, Code. calculation indicates compliance with the Florida Energy Code. irr„���; :-' •• '. , ";, �O PREP RED Y:QPWH�fi DATE - Before construction is completed this building will be inspected for r C compliance with Section 553.908 I herebycertify that this buildi s de fy gned, is in compliance Florida Statutes. � y't with the Florida Energy C '0 yy�T4� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. rile copy 10/5/2017 2:48 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 8 FORM R405-2014 PROJECT Title: HALBERT RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 4335 Lot # Owner: Total Stories: 3 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: SITE 52 WATERSONG Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: ST. LUCIE COUNTY, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 UNIT 1 2570 28772 2 UNIT 2 1765 17650 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 FLEX ROOM 501 5010 No 0 1 Yes Yes Yes 2 LAUND. 65 650 No 0 1 Yes Yes Yes 3 CABANA 100 1000 No 0 1 Yes Yes Yes 4 STAIR 99 990 No 0 1 Yes Yes Yes 5 FOYER 244 2440 No 0 1 Yes Yes Yes 6 ELE 25 250 No 0 1 No Yes Yes 7 GREAT ROOM 564 6768 No 0 1 Yes Yes Yes 8 STAIRWAY 243 2916 No 0 1 Yes Yes Yes 9 KITCHEN 280 3360 Yes 0 1 Yes Yes Yes 10 LAUNDRY 82 984 No 0 1 Yes Yes Yes 11 BEDROOM 4 190 2280 No 1 1 1 Yes Yes Yes 12 ELEVATOR 25 300 No 0 1 No Yes Yes 13 BATH 4 60 720 No 0 1 Yes Yes Yes 14 POWDER 72 864 No 0 1 Yes Yes Yes 15 A/C 2 20 240 No 0 1 No Yes Yes 16 MASTER BATH 200 2000 No 0 1 Yes Yes Yes 17 TOILET 24 240 No 0 1 Yes Yes Yes 18 M WIC 83 830 No 0 1 Yes Yes Yes 19 WIC 48 480 No 0 1 No Yes Yes 20 WIC 2 42 420 No 0 1 Yes Yes Yes 21 MASTER SUITE 415 4150 No 0 1 1 Yes Yes Yes 10/5/2017 2:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 8 FORM R405-2014 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 BEDROOM 2 195 1950 No 0 1 1 Yes Yes Yes 23 HALLWAY 228 2280 No 0 1 Yes Yes Yes 24 STARIWAY. 104 1040 No 0 1 Yes Yes Yes 25 BATH 2 50 500 No 0 1 Yes Yes Yes 26 WIC 3 50 500 No 0 1 Yes Yes Yes 27 BEDROOM 3 168 1680 No 0 1 1 Yes Yes Yes 28 BATH 3 50 500 No 0 1 Yes Yes Yes 29 OFFICE 108 1080 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor FLEX ROOM ---- ____ 501 ft2 19 0 1 0 2 Raised Floor LAUND. ---- ---- 65 ft2 19 0 1 0 3 Raised Floor CABANA ____ ---- 100 ft2 19 0 1 0 4 Raised Floor STAIR ---- ____ 99 ft2 19 0 1 0 5 Raised Floor FOYER ____ ---- 244 ft2 19 0 1 0 6 Raised Floor ELE ---- _--- 25 ft2 19 0 1 0 7 Raised Floor STAIRWAY ____ ---- 56 ft2 19 0 0 1 8 Raised Floor KITCHEN , ---- ---- 70 ft2 19 0 0 1 9 Raised Floor KITCHEN ---- ---- 35 ft2 19 0 1 0 10Raised Floor LAUNDRY ---- ---- 72 ft2 0 0 0 1 11Raised Floor LAUNDRY ____ ---- 10 ft2 19 0 1 0 12Raised Floor BEDROOM 4 ____ ---- 190 ft2 19 0 0 1 13Raised Floor ELEVATOR ____ ---- 25 ft2 19 0 0 1 14Raised Floor BATH 4 ---- ____ 60 ft2 19 0 0 1 15Raised Floor POWDER ---- ____ 8 ft2 19 0 0 1 16Raised Floor POWDER ____ ---- 56 ft2 19 0 1 0 17Raised Floor A/C 2 ____ ---- 5 ft2 19 0 0 1 18Raised Floor MASTER BATH ---- ---- 28 ft2 19 0 1 0 19Raised Floor MASTER SUITE ___- ____ 4.5 ft2 19 0 1 0 20Raised Floor BEDROOM 3 ____ ---- 112 ft2 19 0 1 0 21Raised Floor BATH 3 ---- ---- 40 ft2 19 0 1 0 10/5/2017 2:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 8 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 22Raised Floor OFFICE ---- ---- 81 ft2 19 0 1 0 ROOF V Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 2209 ft2 348 ft2 Light 0.6 No 0.9 No 22 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2096 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) FLEX ROOM 22 Blown 61 ft2 0.1 Wood 2 Under Attic (Unvented) LAUND. 22 Blown 25 ft2 0.1 Wood 3 Under Attic (Unvented) GREAT ROOM 22 Blown 36 ft2 0.1 Wood 4 Under Attic (Unvented) MASTER BATH 22 Blown 200 ft2 0.1 Wood 5 Under Attic (Unvented) TOILET 22 Blown 24 ft2 0.1 Wood 6 Under Attic (Unvented) M WIC 22 Blown 83 ft2 0.1 Wood 7 Under Attic (Unvented) WIC 22 Blown 48 ft2 0.1 Wood 8 Under Attic (Unvented) WIC 2 22 Blown 42 ft2 0.1 Wood 9 Under Attic (Unvented) MASTER SUITE 22 Blown 415 ft2 0.1 Wood 10 Under Attic (Unvented) BEDROOM 2 22 Blown 195 ft2 0.1 Wood 11 Under Attic (Unvented) HALLWAY 22 Blown 228 ft2 0.1 Wood 12 Under Attic (Unvented) STARIWAY. 22 Blown 104 ft2 0.1 Wood 13 Under Attic (Unvented) BATH 2 22 Blown 50 ft2 0.1 Wood 14 Under Attic (Unvented) WIC 3 22 Blown 50 ft2 0.1 Wood 15 Under Attic (Unvented) BEDROOM 3 22 Blown 168 ft2 0.1 Wood 16 Under Attic (Unvented) BATH 3 22 Blown 50 ft2 0.1 Wood 17 Under Attic (Unvented) OFFICE 22 Blown 108 ft2 0.1 Wood WALLS 0 OEnt Adjacent Cavity ity Width In Wall Type Height Sheathing Framing Solar Below _ 1 N Exterior Concrete Block - Int Ins6L.EX ROOM 20 18 0 10 0 180.0 ft2 9 0 0.5 0 2 E Exterior Concrete Block - Int InsFILEX ROOM 20 30 0 10 0 300.0 ft2 9 0 0.5 0 _ 3 S Exterior Concrete Block - Int InsFFLEX ROOM 20 5 0 10 0 50.0 ft2 9 0 0.5 0 4 N Exterior Concrete Block - Int Insul LAUND. 20 10 0 10 0 100.0 ft2 9 0 0.5 0 5 E Exterior Concrete Block - Int Insul LAUND. 20 1 0 10 0 10.0 ft2 9 0 0.5 0 6 W Exterior Concrete Block - Int Insul LAUND. 20 7 0 10 0 70.0 ft2 9 0 0.5 0 7 W Exterior Concrete Block - Int Insul CABANA 20 10 0 10 0 100.0 ft2 9 0 0.5 0 8 W Exterior Concrete Block - Int Insul STAIR 20 11 0 10 0 110.0 ft2 9 0 0.5 0 10/5/2017 2:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 8 FORM R405-2014 WALLS vs Ocot Adjacent To Space Wall Type Cavity 11 le Width Et In Height Et In Arpm Sheathing Framing RA/able EraCtinn Solar Ahqnr Below Grade% 9 S Exterior Concrete Block - Int Insul FOYER 20 8 0 10 0 80.0 ft2 9 0 0.5 0 10 W Exterior Concrete Block - Int Insul FOYER 20 21 0 10 0 210.0 ft2 9 0 0.5 0 11 N Exterior Concrete Block - Int InsGREAT ROO 20 21 0 12 0 252.0 ft2 9 0 0.5 0 12 NE Exterior Concrete Block - Int InsGREAT ROO 20 9 11 12 0 119.0 ft2 9 0 0.5 0 _ 13 E Exterior Concrete Block - Int Ins(HREAT ROO 20 14 0 12 0 168.0 ft2 9 0 0.5 0 14 W Exterior Concrete Block - Int InsGREAT ROO 20 21 0 12 0 252.0 ft2 9 0 0.5 0 15 W Exterior Concrete Block - Int InsLSTAIRWAY 20 24 0 12 0 288.0 ft2 9 0 0.5 0 16 E Exterior Concrete Block - Int InsulKITCHEN 20 14 0 12 0 168.0 ft2 9 0 0.5 0 17 E Exterior Concrete Block - Int InsuLAUNDRY 20 9 0 12 0 108.0 ft2 9 0 0.5 0 18 E Exterior Concrete Block - Int InsHEDROOM 4 20 13 0 12 0 156.0 ft2 9 0 0.5 0 19 S Exterior Concrete Block - Int InsSEDROOM 4 20 14 0 12 0 168.0 ft2 9 0 0.5 0 _20 S Exterior Concrete Block - Int Insul BATH 4 20 5 0 12 0 60.0 ft2 9 0 0.5 0 _21 W Exterior Concrete Block - Int Insul BATH 4 20 4 0 12 0 48.0 ft2 9 0 0.5 0 _22 S Exterior Concrete Block - Int InsuIPOWDER 20 9 0 ( 12 0 108.0 ft2 9 0 0.5 0 _23 W Exterior Concrete Block - Int InsuIPOWDER 20 8 0 12 0 96.0 ft2 9 0 0.5 0 _24 N Exterior Concrete Block - Int InsNASTER BA 20 14 0 10 0 140.0 ft2 9 0 0.5 0 _25 E Exterior Concrete Block - Int InsNASTER BA 20 6 0 10 0 60.0 ft2 9 0 0.5 0 _26 W Exterior Concrete Block - Int InsWASTER BA 20 16 0 10 0 160.0 ft2 9 0 0.5 0 _27 W Exterior Concrete Block - Int Insul TOILET 20 4 0 10 0 40.0 ft2 9 0 0.5 0 _28 W Exterior Concrete Block - Int Insul M WIC 20 12 0 10 0 120.0 ft2 9 0 0.5 0 _29 E Exterior Concrete Block - Int Insul WIC 2 20 6 0 10 0 60.0 ft2 9 0 0.5 0 _30 N Exterior Concrete Block - Int InsIVIASTER SUI 20 14 0 10 0 140.0 ft2 9 0 0.5 0 _31 E Exterior Concrete Block - Int InsMASTER SUI 20 20 0 10 0 200.0 ft2 9 0 0.5 0 32 E Exterior Concrete Block - Int InsSEDROOM 2 20 13 0 10 0 130.0 ft2 9 0 0.5 0 _33 W Exterior Concrete Block - Int InsuHALLWAY 20 7 0 10 0 70.0 ft2 9 0 0.5 0 _34 W Exterior Concrete Block - Int InstSTARIWAY. 20 13 0 10 0 130.0 ft2 9 0 0.5 0 35 E Exterior Concrete Block - Int Insul BATH 2 20 5 0 10 0 50.0 ft2 9 0 0.5 0 36 E Exterior Concrete Block - Int Insul WIC 3 20 5 0 10 0 50.0 ft2 9 0 0.5 0 _37 E Exterior Concrete Block - Int InsBEDROOM 3 20 12 0 10 0 120.0 ft2 9 0 0.5 0 _ 38 S Exterior Concrete Block - Int InsBEDROOM 3 20 14 0 10 0 140.0 ft2 9 0 0.5 0 _39 S Exterior Concrete Block - Int Insul BATH 3 20 5 0 10 0 50.0 ft2 9 0 0.5 0 _40 W Exterior Concrete Block - Int Insul BATH 3 20 3 0 10 0 30.0 ft2 9 0 0.5 0 _41 S Exterior Concrete Block - Int Insul OFFICE 20 9 0 10 0 90.0 ft2 9 0 0.5 0 _42 W Exterior Concrete Block - Int Insul OFFICE 20 12 0 10 0 120.0 ft2 9 0 0.5 0 _43 N Garage Frame - Wood OFFICE 19 10 9 90.0 ft2 0.23 0.5 0 10/5/2017 2:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 8 FORM R405-2014 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 1.06 0.39 80.0 ft2 4 ft 0 in 1 ft 4 in Drapes/blinds Exterior 1 2 E 2 Vinyl Low-E Double Yes 0.79 0.28 40.0 ft2 2 ft 0 in 7 ft 0 in None None 3 N 4 Vinyl Low-E Double Yes 0.79 0.28 24.0 ft2 2 ft 0 in 7 ft 0 in None None 4 W 7 Vinyl Low-E Double Yes 0.79 0.28 10.0 ft2 2 ft 0 in 1 ft 4 in None None 5 S 9 Vinyl Low-E Double Yes 0.79 0.28 48.0 ft2 5 ft 0 in 1 ft 4 in None None 6 W 10 Vinyl Low-E Double Yes 0.79 0.28 40.0 ft2 2 ft 0 in 1 ft 4 in None None 7 N 11 Vinyl Low-E Double Yes 1.06 0.39 112.0 ft2 8 ft 0 in 1 ft 4 in None None 8 NE 12 Vinyl Low-E Double Yes 1.06 0.39 62.0 ft2 10 ft 0 in 1 ft 4 in None None 9 E 13 Vinyl Low-E Double Yes 0.79 0.28 56.0 ft2 2 ft 0 in 1 ft 4 in None None 10 W 14 Vinyl Low-E Double Yes 0.79 0.28 42.0 ft2 2 ft 0 in 1 ft 4 in None None 11 W 15 Vinyl Low-E Double Yes 0.79 0.28 24.0 ft2 2 ft 0 in 1 ft 4 in None None 12 E 16 Vinyl Low-E Double Yes 0.79 0.28 18.0 ft2 2 ft 0 in 1 ft 4 in None None 13 E 17 Vinyl Low-E Double Yes 0.79 0.28 14.0 ft2 2 ft 0 in 1 ft 4 in None None 14 E 18 Vinyl Low-E Double Yes 0.79 0.28 28.0 ft2 2 ft 0 in 1 ft 4 in None None 15 S 19 Vinyl Low-E Double Yes 0.79 0.28 40.0 ft2 5 ft 0 in 1 ft 4 in Drapes/blinds Exterior 1 16 S 19 Vinyl Low-E Double Yes 0.79 0.28 5.0 ft2 5 ft 0 in 1 ft 4 in None None 17 S 19 Vinyl Low-E Double Yes 0.79 0.28 8.0 ft2 2 ft 0 in 1 ft 4 in None None 18 S 20 Vinyl Low-E Double Yes 0.79 0.28 8.0 ft2 2 ft 0 in 1 ft 4 in None None 19 W 23 Vinyl Low-E Double Yes 0.79 0.28 8.0 ft2 2 ft 0 in 1 ft 4 in None None 20 N 24 Vinyl Low-E Double Yes 0.22 0.17 18.0 ft2 2 ft 0 in 1 ft 4 in None None 21 N 24 Vinyl Low-E Double Yes 0.22 0.17 24.0 ft2 2 ft 0 in 1 ft 4 in None None 22 W 27 Vinyl Low-E Double Yes 0.79 0.28 10.0 ft2 2 ft 0 in 1 ft 4 in None None 23 N 30 Vinyl Low-E Double Yes 1.06 0.3 80.0 ft2 8 ft 8 in 1 ft 4 in None None 24 E 31 Vinyl Low-E Double Yes 0.79 0.28 20.0 ft2 2 ft 0 in 1 ft 4 in None None 25 E 32 Vinyl Low-E Double Yes 0.79 0.28 20.0 ft2 2 ft 0 in 1 ft 4 in None None 26 W 33 Vinyl Low-E Double Yes 0.79 0.28 20.0 ft2 2 ft 0 in 1 ft 4 in None None 27 E 35 Vinyl Low-E Double Yes 0.79 0.28 10.0 ft2 2 ft 0 in 1 ft 4 in None None 28 E 37 Vinyl Low-E Double Yes 0.79 0.28 20.0 ft2 2 ft 0 in 1 ft 4 in None None 29 S 38 Vinyl Low-E Double Yes 0.79 0.28 40.0 ft2 5 ft 0 in 9 ft 0 in None None 30 S 38 Vinyl Low-E Double Yes 0.79 0.28 10.0 ft2 2 ft 0 in 1 ft 4 in None None 31 S 39 Vinyl Low-E Double Yes 0.79 0.28 10.0 ft2 2 ft 0 in 1 ft 4 in None None 32 S 41 Vinyl Low-E Double Yes 0.79 0.28 40.0 ft2 5 ft 0 in 9 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft2 400 ft2 loft 9 ft 19 10/5/2017 2:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 8 FORM R405-2014 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000476 5415.9 297.33 559.16 .4834 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat Electric Strip Heat None None COP:1 34 kBtu/hr COP:1 27 kBtu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Central Unit Split Split SEER: 17 48 kBtu/hr cfm 0.8 SEER: 17.5 36 kBtu/hr cfm 0.8 1 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 80 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V # — Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 425 ft2 Attic 6 325 ft2 Attic Attic 75 ft2 Default Leakage Attic (Default) (Default) 95 ft2 Default Leakage Attic (Default) (Default) 1 1 2 2 TEMPERATURES Programable Thermostat: Y CoolingJan Feb [[ ]Mar HeatinJan Feb [X] Mar Ventin Jan Feb [X Mar Ceiling Fans: Jul rl Au �Xl Se Oct f Apr f MaY Jun Jul AuSeP Oct Apr Ma rj Jun rl [X A r [ Ma Jun JulAug Se [X] Oct Nov [X� Nov [[[X Nov ]Dec X] Dec [ ] Dec 10/5/2017 2:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 7 of 8 FORM R405-2014 Thermostat Schedule: Schedule Type HERS 2006 Reference 1 2 3 4 5 Hours 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/5/2017 2:48 PM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 8 of 8 FORM R405-2014 TABLE 402.4.1. AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HALBERT RESIDENCE Builder Name: Street: SITE 52 WATERSONG Permit Office: ST.. LUCIE COUNTY City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 10/5/2017 2:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1