HomeMy WebLinkAboutEnergy Efficiency CodeC R
I
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: HALBERT RESIDENCE
Builder Name:
Street: SITE 52 WATERSONG
Permit Office: ST. LUCIE COUNTY
City, State, Zip: ST. LUCIE COUNTY, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County:: ST. LUCIE COUNTY (Florida
Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (5191.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=20.0 5101.00 ft2
b. Frame - Wood, Adjacent
R=19.0 90.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1887.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=22.0 1887.00 ft2
6. Conditioned floor area above grade (ft2) 4335
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= . ft2
11. Ducts
R ft2
7. Windows(989.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 425
a. U-Factor: Dbl, U=0.79 613.00 ft2
b. Sup: Attic, Ret: Attic, AH: Attic
6 325
SHGC: SHGC=0.28
b. U-Factor: Dbl, U=1.06 254.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.39
a. Central Unit
48.0 SEER:17.00
c. U-Factor: Dbl, U=1.06 80.00 ft2
b. Central Unit
36.0 SEER:17.50
SHGC: SHGC=0.30
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 42.00 ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC: other (see details)
b. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average Overhang Depth: 4.407 ft.
Area Weighted Average SHGC: 0.305
14. Hot water systems
8. Floor Types (18,86.5 sqft.) Insulation Area
a. Electric
Cap: 80 gallons
a. Raised Floor R=19.0 1814.50 ft2
b. Conservation features
EF: 0.950
b. Raised Floor R=0.0 72.00 ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.228 Total Proposed Modified Loads: 149.65
PASS
Total Baseline Loads: 152.03
I hereby certify that the plans and specifications covered by
Review of the plans and
Srg?�
this calculation are in compliance withtheFlorida Energy
specifications covered by this
o�TgE
1+ s Off,
Code.
calculation indicates compliance
with the Florida Energy Code.
irr„���; :-' •• '. , ";, �O
PREP RED Y:QPWH�fi
DATE -
Before construction is completed
this building will be inspected for
r C
compliance with Section 553.908
I herebycertify that this buildi s de
fy gned, is in compliance
Florida Statutes.
� y't
with the Florida Energy C
'0 yy�T4�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
rile copy
10/5/2017 2:48 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 8
FORM R405-2014
PROJECT
Title:
HALBERT RESIDENCE
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 4335
Lot #
Owner:
Total Stories: 3
Block/SubDivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
SITE 52 WATERSONG
Permit Office:
ST. LUCIE COUNTY
Cross Ventilation: No
County:
ST. LUCIE COUNTY
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
ST. LUCIE COUNTY,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
IECC Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
UNIT 1
2570
28772
2
UNIT 2
1765
17650
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
FLEX ROOM
501
5010 No
0
1
Yes
Yes
Yes
2
LAUND.
65
650 No
0
1
Yes
Yes
Yes
3
CABANA
100
1000 No
0
1
Yes
Yes
Yes
4
STAIR
99
990 No
0
1
Yes
Yes
Yes
5
FOYER
244
2440 No
0
1
Yes
Yes
Yes
6
ELE
25
250 No
0
1
No
Yes
Yes
7
GREAT ROOM
564
6768 No
0
1
Yes
Yes
Yes
8
STAIRWAY
243
2916 No
0
1
Yes
Yes
Yes
9
KITCHEN
280
3360 Yes
0
1
Yes
Yes
Yes
10
LAUNDRY
82
984 No
0
1
Yes
Yes
Yes
11
BEDROOM 4
190
2280 No
1
1
1
Yes
Yes
Yes
12
ELEVATOR
25
300 No
0
1
No
Yes
Yes
13
BATH 4
60
720 No
0
1
Yes
Yes
Yes
14
POWDER
72
864 No
0
1
Yes
Yes
Yes
15
A/C 2
20
240 No
0
1
No
Yes
Yes
16
MASTER BATH
200
2000 No
0
1
Yes
Yes
Yes
17
TOILET
24
240 No
0
1
Yes
Yes
Yes
18
M WIC
83
830 No
0
1
Yes
Yes
Yes
19
WIC
48
480 No
0
1
No
Yes
Yes
20
WIC 2
42
420 No
0
1
Yes
Yes
Yes
21
MASTER SUITE
415
4150 No
0
1
1
Yes
Yes
Yes
10/5/2017 2:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 8
FORM R405-2014
SPACES
Number Name
Area Volume
Kitchen Occupants
Bedrooms
InfilID
Finished
Cooled
Heated
22
BEDROOM 2
195 1950
No
0
1
1
Yes
Yes
Yes
23
HALLWAY
228 2280
No
0
1
Yes
Yes
Yes
24
STARIWAY.
104 1040
No
0
1
Yes
Yes
Yes
25
BATH 2
50 500
No
0
1
Yes
Yes
Yes
26
WIC 3
50 500
No
0
1
Yes
Yes
Yes
27
BEDROOM 3
168 1680
No
0
1
1
Yes
Yes
Yes
28
BATH 3
50 500
No
0
1
Yes
Yes
Yes
29
OFFICE
108 1080
No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Raised Floor
FLEX ROOM
---- ____
501 ft2
19
0
1
0
2 Raised Floor
LAUND.
---- ----
65 ft2
19
0
1
0
3 Raised Floor
CABANA
____ ----
100 ft2
19
0
1
0
4 Raised Floor
STAIR
---- ____
99 ft2
19
0
1
0
5 Raised Floor
FOYER
____ ----
244 ft2
19
0
1
0
6 Raised Floor
ELE
---- _---
25 ft2
19
0
1
0
7 Raised Floor
STAIRWAY
____ ----
56 ft2
19
0
0
1
8 Raised Floor
KITCHEN ,
---- ----
70 ft2
19
0
0
1
9 Raised Floor
KITCHEN
---- ----
35 ft2
19
0
1
0
10Raised Floor
LAUNDRY
---- ----
72 ft2
0
0
0
1
11Raised Floor
LAUNDRY
____ ----
10 ft2
19
0
1
0
12Raised Floor
BEDROOM 4
____ ----
190 ft2
19
0
0
1
13Raised Floor
ELEVATOR
____ ----
25 ft2
19
0
0
1
14Raised Floor
BATH 4
---- ____
60 ft2
19
0
0
1
15Raised Floor
POWDER
---- ____
8 ft2
19
0
0
1
16Raised Floor
POWDER
____ ----
56 ft2
19
0
1
0
17Raised Floor
A/C 2
____ ----
5 ft2
19
0
0
1
18Raised Floor
MASTER BATH
---- ----
28 ft2
19
0
1
0
19Raised Floor
MASTER SUITE
___- ____
4.5 ft2
19
0
1
0
20Raised Floor
BEDROOM 3
____ ----
112 ft2
19
0
1
0
21Raised Floor
BATH 3
---- ----
40 ft2
19
0
1
0
10/5/2017 2:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 8
FORM R405-2014
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
22Raised Floor OFFICE ----
----
81 ft2
19
0
1
0
ROOF
V
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
#
Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1
Gable or Shed Metal 2209 ft2
348 ft2
Light
0.6
No
0.9
No
22
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Unvented
0
2096 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented) FLEX ROOM
22
Blown
61 ft2
0.1
Wood
2
Under Attic (Unvented) LAUND.
22
Blown
25 ft2
0.1
Wood
3
Under Attic (Unvented) GREAT ROOM
22
Blown
36 ft2
0.1
Wood
4
Under Attic (Unvented) MASTER BATH
22
Blown
200 ft2
0.1
Wood
5
Under Attic (Unvented) TOILET
22
Blown
24 ft2
0.1
Wood
6
Under Attic (Unvented) M WIC
22
Blown
83 ft2
0.1
Wood
7
Under Attic (Unvented) WIC
22
Blown
48 ft2
0.1
Wood
8
Under Attic (Unvented) WIC 2
22
Blown
42 ft2
0.1
Wood
9
Under Attic (Unvented) MASTER SUITE
22
Blown
415 ft2
0.1
Wood
10
Under Attic (Unvented) BEDROOM 2
22
Blown
195 ft2
0.1
Wood
11
Under Attic (Unvented) HALLWAY
22
Blown
228 ft2
0.1
Wood
12
Under Attic (Unvented) STARIWAY.
22
Blown
104 ft2
0.1
Wood
13
Under Attic (Unvented) BATH 2
22
Blown
50 ft2
0.1
Wood
14
Under Attic (Unvented) WIC 3
22
Blown
50 ft2
0.1
Wood
15
Under Attic (Unvented) BEDROOM 3
22
Blown
168 ft2
0.1
Wood
16
Under Attic (Unvented) BATH 3
22
Blown
50 ft2
0.1
Wood
17
Under Attic (Unvented) OFFICE
22
Blown
108 ft2
0.1
Wood
WALLS
0
OEnt
Adjacent Cavity ity Width
In Wall Type
Height
Sheathing Framing
Solar
Below
_ 1
N
Exterior Concrete Block - Int Ins6L.EX ROOM
20 18
0 10
0
180.0 ft2
9
0
0.5
0
2
E
Exterior Concrete Block - Int InsFILEX ROOM
20 30
0 10
0
300.0 ft2
9
0
0.5
0
_ 3
S
Exterior Concrete Block - Int InsFFLEX ROOM
20 5
0 10
0
50.0 ft2
9
0
0.5
0
4
N
Exterior Concrete Block - Int Insul LAUND.
20 10
0 10
0
100.0 ft2
9
0
0.5
0
5
E
Exterior Concrete Block - Int Insul LAUND.
20 1
0 10
0
10.0 ft2
9
0
0.5
0
6
W
Exterior Concrete Block - Int Insul LAUND.
20 7
0 10
0
70.0 ft2
9
0
0.5
0
7
W
Exterior Concrete Block - Int Insul CABANA
20 10
0 10
0
100.0 ft2
9
0
0.5
0
8
W
Exterior Concrete Block - Int Insul STAIR
20 11
0 10
0
110.0 ft2
9
0
0.5
0
10/5/2017 2:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 8
FORM R405-2014
WALLS
vs
Ocot
Adjacent
To
Space
Wall Type
Cavity
11 le
Width
Et In
Height
Et In
Arpm
Sheathing Framing
RA/able EraCtinn
Solar
Ahqnr
Below
Grade%
9
S
Exterior
Concrete Block - Int Insul FOYER
20
8
0
10
0
80.0 ft2
9
0
0.5
0
10
W
Exterior
Concrete Block - Int Insul FOYER
20
21
0
10
0
210.0 ft2
9
0
0.5
0
11
N
Exterior
Concrete Block - Int InsGREAT ROO
20
21
0
12
0
252.0 ft2
9
0
0.5
0
12
NE
Exterior
Concrete Block - Int InsGREAT ROO
20
9
11
12
0
119.0 ft2
9
0
0.5
0
_ 13
E
Exterior
Concrete Block - Int Ins(HREAT ROO
20
14
0
12
0
168.0 ft2
9
0
0.5
0
14
W
Exterior
Concrete Block - Int InsGREAT ROO
20
21
0
12
0
252.0 ft2
9
0
0.5
0
15
W
Exterior
Concrete Block - Int InsLSTAIRWAY
20
24
0
12
0
288.0 ft2
9
0
0.5
0
16
E
Exterior
Concrete Block - Int InsulKITCHEN
20
14
0
12
0
168.0 ft2
9
0
0.5
0
17
E
Exterior
Concrete Block - Int InsuLAUNDRY
20
9
0
12
0
108.0 ft2
9
0
0.5
0
18
E
Exterior
Concrete Block - Int InsHEDROOM 4
20
13
0
12
0
156.0 ft2
9
0
0.5
0
19
S
Exterior
Concrete Block - Int InsSEDROOM 4
20
14
0
12
0
168.0 ft2
9
0
0.5
0
_20
S
Exterior
Concrete Block - Int Insul BATH 4
20
5
0
12
0
60.0 ft2
9
0
0.5
0
_21
W
Exterior
Concrete Block - Int Insul BATH 4
20
4
0
12
0
48.0 ft2
9
0
0.5
0
_22
S
Exterior
Concrete Block - Int InsuIPOWDER
20
9
0 (
12
0
108.0 ft2
9
0
0.5
0
_23
W
Exterior
Concrete Block - Int InsuIPOWDER
20
8
0
12
0
96.0 ft2
9
0
0.5
0
_24
N
Exterior
Concrete Block - Int InsNASTER BA
20
14
0
10
0
140.0 ft2
9
0
0.5
0
_25
E
Exterior
Concrete Block - Int InsNASTER BA
20
6
0
10
0
60.0 ft2
9
0
0.5
0
_26
W
Exterior
Concrete Block - Int InsWASTER BA
20
16
0
10
0
160.0 ft2
9
0
0.5
0
_27
W
Exterior
Concrete Block - Int Insul TOILET
20
4
0
10
0
40.0 ft2
9
0
0.5
0
_28
W
Exterior
Concrete Block - Int Insul M WIC
20
12
0
10
0
120.0 ft2
9
0
0.5
0
_29
E
Exterior
Concrete Block - Int Insul WIC 2
20
6
0
10
0
60.0 ft2
9
0
0.5
0
_30
N
Exterior
Concrete Block - Int InsIVIASTER SUI
20
14
0
10
0
140.0 ft2
9
0
0.5
0
_31
E
Exterior
Concrete Block - Int InsMASTER SUI
20
20
0
10
0
200.0 ft2
9
0
0.5
0
32
E
Exterior
Concrete Block - Int InsSEDROOM 2
20
13
0
10
0
130.0 ft2
9
0
0.5
0
_33
W
Exterior
Concrete Block - Int InsuHALLWAY
20
7
0
10
0
70.0 ft2
9
0
0.5
0
_34
W
Exterior
Concrete Block - Int InstSTARIWAY.
20
13
0
10
0
130.0 ft2
9
0
0.5
0
35
E
Exterior
Concrete Block - Int Insul BATH 2
20
5
0
10
0
50.0 ft2
9
0
0.5
0
36
E
Exterior
Concrete Block - Int Insul WIC 3
20
5
0
10
0
50.0 ft2
9
0
0.5
0
_37
E
Exterior
Concrete Block - Int InsBEDROOM 3
20
12
0
10
0
120.0 ft2
9
0
0.5
0
_ 38
S
Exterior
Concrete Block - Int InsBEDROOM 3
20
14
0
10
0
140.0 ft2
9
0
0.5
0
_39
S
Exterior
Concrete Block - Int Insul BATH 3
20
5
0
10
0
50.0 ft2
9
0
0.5
0
_40
W
Exterior
Concrete Block - Int Insul BATH 3
20
3
0
10
0
30.0 ft2
9
0
0.5
0
_41
S
Exterior
Concrete Block - Int Insul OFFICE
20
9
0
10
0
90.0 ft2
9
0
0.5
0
_42
W
Exterior
Concrete Block - Int Insul OFFICE
20
12
0
10
0
120.0 ft2
9
0
0.5
0
_43
N
Garage
Frame - Wood OFFICE
19
10
9
90.0 ft2
0.23
0.5
0
10/5/2017 2:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 8
FORM R405-2014
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt
ID
Frame
Panes
NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1
N
1
Vinyl
Low-E Double
Yes
1.06
0.39
80.0 ft2
4 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 1
2
E
2
Vinyl
Low-E Double
Yes
0.79
0.28
40.0 ft2
2 ft 0 in
7 ft 0 in
None
None
3
N
4
Vinyl
Low-E Double
Yes
0.79
0.28
24.0 ft2
2 ft 0 in
7 ft 0 in
None
None
4
W
7
Vinyl
Low-E Double
Yes
0.79
0.28
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5
S
9
Vinyl
Low-E Double
Yes
0.79
0.28
48.0 ft2
5 ft 0 in
1 ft 4 in
None
None
6
W
10
Vinyl
Low-E Double
Yes
0.79
0.28
40.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
N
11
Vinyl
Low-E Double
Yes
1.06
0.39
112.0 ft2
8 ft 0 in
1 ft 4 in
None
None
8
NE
12
Vinyl
Low-E Double
Yes
1.06
0.39
62.0 ft2
10 ft 0 in
1 ft 4 in
None
None
9
E
13
Vinyl
Low-E Double
Yes
0.79
0.28
56.0 ft2
2 ft 0 in
1 ft 4 in
None
None
10
W
14
Vinyl
Low-E Double
Yes
0.79
0.28
42.0 ft2
2 ft 0 in
1 ft 4 in
None
None
11
W
15
Vinyl
Low-E Double
Yes
0.79
0.28
24.0 ft2
2 ft 0 in
1 ft 4 in
None
None
12
E
16
Vinyl
Low-E Double
Yes
0.79
0.28
18.0 ft2
2 ft 0 in
1 ft 4 in
None
None
13
E
17
Vinyl
Low-E Double
Yes
0.79
0.28
14.0 ft2
2 ft 0 in
1 ft 4 in
None
None
14
E
18
Vinyl
Low-E Double
Yes
0.79
0.28
28.0 ft2
2 ft 0 in
1 ft 4 in
None
None
15
S
19
Vinyl
Low-E Double
Yes
0.79
0.28
40.0 ft2
5 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 1
16
S
19
Vinyl
Low-E Double
Yes
0.79
0.28
5.0 ft2
5 ft 0 in
1 ft 4 in
None
None
17
S
19
Vinyl
Low-E Double
Yes
0.79
0.28
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
18
S
20
Vinyl
Low-E Double
Yes
0.79
0.28
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
19
W
23
Vinyl
Low-E Double
Yes
0.79
0.28
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
20
N
24
Vinyl
Low-E Double
Yes
0.22
0.17
18.0 ft2
2 ft 0 in
1 ft 4 in
None
None
21
N
24
Vinyl
Low-E Double
Yes
0.22
0.17
24.0 ft2
2 ft 0 in
1 ft 4 in
None
None
22
W
27
Vinyl
Low-E Double
Yes
0.79
0.28
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
23
N
30
Vinyl
Low-E Double
Yes
1.06
0.3
80.0 ft2
8 ft 8 in
1 ft 4 in
None
None
24
E
31
Vinyl
Low-E Double
Yes
0.79
0.28
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
25
E
32
Vinyl
Low-E Double
Yes
0.79
0.28
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
26
W
33
Vinyl
Low-E Double
Yes
0.79
0.28
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
27
E
35
Vinyl
Low-E Double
Yes
0.79
0.28
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
28
E
37
Vinyl
Low-E Double
Yes
0.79
0.28
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
29
S
38
Vinyl
Low-E Double
Yes
0.79
0.28
40.0 ft2
5 ft 0 in
9 ft 0 in
None
None
30
S
38
Vinyl
Low-E Double
Yes
0.79
0.28
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
31
S
39
Vinyl
Low-E Double
Yes
0.79
0.28
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
32
S
41
Vinyl
Low-E Double
Yes
0.79
0.28
40.0 ft2
5 ft 0 in
9 ft 0 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
400 ft2
400 ft2
loft
9 ft
19
10/5/2017 2:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 8
FORM R405-2014
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000476
5415.9 297.33 559.16 .4834 7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
2
Electric Strip Heat
Electric Strip Heat
None
None
COP:1 34 kBtu/hr
COP:1 27 kBtu/hr
1
2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR
Block
Ducts
1
2
Central Unit
Central Unit
Split
Split
SEER: 17 48 kBtu/hr cfm 0.8
SEER: 17.5 36 kBtu/hr cfm 0.8
1
2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.95 80 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
V #
— Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN
RLF
HVAC #
Heat Cool
1
2
Attic 6 425 ft2
Attic 6 325 ft2
Attic
Attic
75 ft2 Default Leakage Attic (Default) (Default)
95 ft2 Default Leakage Attic (Default) (Default)
1 1
2 2
TEMPERATURES
Programable Thermostat: Y
CoolingJan Feb [[ ]Mar
HeatinJan Feb [X] Mar
Ventin Jan Feb [X Mar
Ceiling Fans:
Jul rl Au �Xl Se Oct
f Apr f MaY Jun Jul AuSeP Oct
Apr Ma rj Jun rl
[X A r [ Ma Jun JulAug Se [X] Oct
Nov
[X� Nov
[[[X Nov
]Dec
X] Dec
[ ] Dec
10/5/2017 2:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 7 of 8
FORM R405-2014
Thermostat Schedule:
Schedule Type
HERS 2006
Reference
1
2
3
4
5
Hours
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
10/5/2017 2:48 PM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 8 of 8
FORM R405-2014
TABLE 402.4.1.
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: HALBERT RESIDENCE Builder Name:
Street: SITE 52 WATERSONG Permit Office: ST.. LUCIE COUNTY
City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
10/5/2017 2:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1