Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutTrussRECL. n"T 17 2917
A-1 ROOF
TRU55E5
A FLORIDA.CORPORATION
RE: Job 69778
Site Information:
Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3
These truss designs rely on lumber values established by others.
A-1 Roof Trusses
4451 St Lucie Blvd
Fort Pierce, FL 34946
Customer Info: COASTAL CONSTRUCTION AND DESIGN, INC. Project Name: HALBERT LOT 52 WATERSONG
Lot/Block: Model:
Address: SITE 52 WATERSONG, ST LUCIE COUNTYubdivision:
City: County: St Lucie State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: James Bushouse License #: 20311
Address: 1176 SW 4th Court
City: Boca Raton, FL 33432
General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2014/TP12007 Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10 Wind Speed: 170 MPH
Roof Load: 46.0 psf Floor Load: 0.0 psf
This package includes -107 individual, dated Truss Design Drawings and 16 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I; am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal #
Truss Name
Date
No.
Seal #
Truss Name
Date
No.
Seal #
Truss Name
Date
1
A0129122
A01
10/17/17
13
A0129134
A13
10/17/17
25
A0129146
CJ3P
10/17/17
2
A0129123
A02
10/17/17
14
A0129135
A14
10/17/17
26
A0129147
CJ5
10/17/17
3
A0129124
A02A
10/17/17
15
A0129136
1301
10/17/17
27
A0129148
CJ5A
10/17/17
4
A0129125
A04
10/17/17
16
A0129137
B02
10117/171
28
1 A0129149
CJ5P
10/17117.
5
A0129126
A05
10/17/17
17
A0129138
B03
10/17/17
29
1 A0129150
HJ1
10/17/17
6
A0129127
A06
10/17/17
18
A0129139
B04
10/17/17
30
A0129151
HJ2
10/17/17
7
A0129128
A07
10/17/17
19
A0129140
CA
10/17117
31
A0129152
HJ2A
10/17117
8
A0129129
A08
10/17/171
20
A0129141
CJ1A
10/17/17
32
A0129153
HJ2B
10/17/17
9
A0129130
A09
10/17/17
21
A0129142
CAB
10/17117
33
A0129154
HJ2C
10/17/17
10
A0129131
A10
10/17/17
22
A0129143
CJ3
10/17/17
34
A0129155
HJ2P
10/17/17
11
A0129132
All
10/17/17
23
A0129144
CJ3A
10/17/17
35
A0129156
I HJ3
10/17/17
12
A0129133
I Al2
10/17/17
24
A0129145
I CJ36
10/17/17
36;
1 A0129157
1 J4
10/17/17
The truss drawing(s) referenced have been prepared by MiTek Industries, Inc. under my direct
sunervision based on the Darameters Drovided by A-1 Roof Trusses. Ltd.
Truss Design Engineer's Name: Anthony Tombo III
My license renewal date for the state of Florida is February 28,2019.
NOTE.The seal on these drawings indicate acceptance of professional
engineering responsibility solely for the truss components shown.
The suitability and use of components for any particular building is the responsibility of the
building designer, perANSI1TPl-1 Sec. 2.
The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the
construction documents (also referred to at times as 'Structural Engineering Documents)
provided by the Building Designer indicating the nature and character of the work.
The design criteria therein have been transferred to Anthony Tombo III PE by [A1 Roof
Trusses or specific location]. These TDDs (also referred to at times as 'Structural
Engineering Documents) are specialty structural component designs and may be part of the
projects deferred or phased submittals. As a Truss Design Engineer (i.e., Specialty
Engineer), the seal here and on the TDD represents an acceptance of professional Anthony T.
engineering responsibility for the design of the single Truss depicted on the TDD only. The
Building Designer is responsible for and shall coordinate and review the TDDs for
compatibility with their written engineering requirements. Please review all TDDs and all
related notes.
Page 1 of 2
This item has been electronically signed and sealed by Antnony Iombo ]II,
on 10/17i17 using a.dlgita,I signature:
Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3
/44 ROOF These truss designs rely on lumber values established by others.
TRUSSES
A. FLORID.ACORFORATION,
RE: Job 69778
No.
Seal #
Truss Name
Date
37
A0129158
J5A
10/17/17
38
A0129159
J6
10/17/17
39
A0129160
J7
10117/17
40
A0129161
HA
10/17/17
41
A0129162
J7P
10/17/17
42
A0129163
MG01
10/17/17
43
A0129164
MG02
10/17/17
44
STDL01
STD. DETAIL
10/17/17
45
STDL02
STD. DETAIL
10/17/17
46
STDL03
STD. DETAIL
10/17/17
47
STDL04
STD. DETAIL
10/17/17
48
STDL05
STD. DETAIL
10/17/17
49
STDL06
STD. DETAIL
10/17/17
50
STDL07
STD. DETAIL
10/17/17
51
STDL08
STD. DETAIL
10/17/17
52
STDL09
STD. DETAIL
10/17/17
53
STDL10
STD. DETAIL
10/17/17
54 1
STDL11 .
STD. DETAIL
10/17/17
55
STDL12
STD. DETAIL
10/17/17
56
STOL13
STD. DETAIL
10/17/17
57
STDL14
STD. DETAIL
10/17/17
58
STDL15
STD. DETAIL
10/17/17
59
STDL16
STD. DETAIL
10/17/17
Page 2 of 2
Job
Truss
Truss Type
Qty
Ply
A0129122
69778
A01
Common
1
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@al truss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44:34 2017 Page 1
ID:IMTa5WVdxJ7_cFOOWg_MyeyiLhV-cnh9WijBIAM01UTEeAAhBXI ToTnZ5ODeNOrg2ySYMh
84
-8 16-0-0 i 23-7.8 i 32-0-0
-0-8 i
87-7-88-0-8
7.00 12 5x8 =
14 21 22 13 23 12 24 11 25 Zb 10
Dead Load Defl. = 5/16 in
3x4 =
4x6 =
3x4 =
3x10 II
3x8 =
2-4-0
32-M =
2-0-01.dn II
11-53
20-6.13
294"
30,Q-0
2-2-M
9-1-3
9.1-10
9-1-3
o
0-4-0
2-M
Plate Offsets (X Y)—
[1:0-8-0Edge] [9:0-8-0Edgel
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.89
Vert(LL)
-0.22 11-13
>999
360
MT20 244/190
TCDL 16.0
Lumber DOL 1.25
BC
0.79
Vert(TL)
-0.55 11-13
>593
240
BCLL 0.0
Rep Stress Incr YES
WB
0.85
Horz(TL)
0.04 10
n/a
n/a
BCDL 10.0
Code FBC2014/rP12007
Matrix -MS
Wind(LL)
0.31 11-13
>999
240
Weight: 213 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
puriins.
BOT CHORD
Rigid ceiling directly applied or 6-4-14 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
14 =
1472/0-8-0 (min. 0-1-13)
10 =
1472/0-8-0 (min. 0-1-13)
Max Horz
14 =
525(LC 9)
Max Uplift
14 =
-765(LC 12)
10 =
-765(LC 13)
Max Grav
14 =
1562(LC 19)
10 =
1562(LC 20)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=1681/839, 2-3=-2447/1505,
3-4=-2316/1482, 4-5=-225B/l511,
5-6=-2258/1511, 6-7=-2316/1482,
7-8=2447/1505, 8-9=1681/839
BOT CHORD
1-14=-918/1728, 14-21=-918/1737,
21-22=-918/1737, 13-22=-918/1737,
13-23=382/1203, 12-23=-382/1203,
12-24=-382/1203,11-24=-382/1203,
11-25=918/1728, 25-26=-918/1728,
10-26=-918/1728,9-10=-918/1728
WEBS
5-11=-415/721, 7-11=-682/648,
5-13=-4151721, 3-13=-682/648,
2-14=1566/1263,8-10=-1566/1263
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
4)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.Opsf.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 765 lb uplift at
joint 14 and 765 lb uplift at joint 10.
LOAD CASE(S)
Standard
tear-n�,amyulR.�. m•ia roar nosse[uuu3at�r mtn a cmomass rosrou4-rarayursustt�unr m:n r�mm �ammmi r : un:mnu::nmF,�{laq®am ra�gt rut: m,r� retrm,,fw:ra.e:v uiEc+:n�.�::mdom rtn..ar
wlsto dm:strllki:drxd<xar::aaurrmso rr�3(u,-ymruPeadesdusftmymmo:eya:amrntsudey,w�mr �aaxr:u;duesuyarmirysanaetooalr.utamirgkq:sao8a�gm�ucard�ne Anthony T.Tombaft,,P.E.
orn:dry:rm:ru�uu*:rum::q::.�gama.m,ma:eAnhel gr6nMktfapa�¢e,n&utled dSe aC�e lt(dmlmi�igoHdmL ltr gHmia8:0aWagf•Omd9:ims,hd�fnr6ndsy avyama"a5aalkaur sidlkhngmWiryd 380083
merar�o:pval6ef:meraedusamae�tapufzePcaa�rr sdlEafarO;salk4rytuzdmalOQrdfidallrlrnlSQlc':doxnldry�dradQetFFlido:s&rtgnbdn®/GMtdlkLn.0. e,Trcnce�:rNnaorrn:su u n,d:ss' 4451it.LucieBIA.
:dn,InkScNN:raemgmdgnhhblhal rv7as anh:l l6 rmtCeUp6�uaranU rtitligartlrx:,nLnslyd:s erwv a:gtsl4q. laaµdReltn�;maraud ieIDl. Fort Pierce, FL 34946
(opyright®1QI66dtoolT:osses•AmhooyLlomhoiO,P.E Rtprodoniaaollhisdommeoyioeoyform,isp:ohihdelrhhootiheminenprmiscicoheoklPoolimsrer-WhonyT.TanhoIII,P.r.
Job
Truss
Truss Type
Qty
Ply
69778
A02
Attic
12
1
A0129123
Job Reference (optional)
Al Root Trusses, Fort Pierce, FL 34946, design@altruss.com
Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44:35 2017 Page 1
I0:IMTa5V VdxJ7_cF0OWg_MyeyiLhV-5zFXk2jpVUUFfe2QBthwklgDpCmfleXNt1mPMUySYMg
13.1-5
20-1-12
i
11-104 11-A-5i
- -2-0-0
&1101Al2 29139 37-0-7
�70-7
707
4-9.13 11
20011
1-2-6
D-0-11
7.00 12
5x6 =
3x4 =
Dead Load Defl. =1/4 in
2x4 11
5
3x4 =
5x6 i
8 2x4 II
6
5
9 5x6
4
19
10
2x4
1.5x4 11
2x4 �i
317
11
3x8 II
2
3x8 11
12
1
2
130
10
C5
18
17
16
_ o
15 14
_
3x10 =
3x4 =
5x10 MT20HS=
3x4 = 3x10 II
2-0-0
32WO =
2�J1 11-104
20.1-12
29-8-0 L
2-M 9-0A
8-3A
9-6-4 ow
04-0
2-M
Plate Offsets (X,Y)—
[1:0-10-0,0-1-141,[13:0-10-0,0-1-141
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.53
Vert(LL)
-0.29 15-17 >999 360
MT20 244/190
TCDL 16.0
Lumber DOL 1.25
BC 1.00
Vert(TL)
-0.53 15-17 >617 240
MT20HS 187/143
BCLL 0.0 '
Rep Stress Incr YES
WB 0.45
Horz(TL)
0.05 14 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
Matrix -MS
Wind(LL)
0.34 17-18 >962 240
Weight: 216 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2 *Except*
T1: 2x6 SP 2400F 2.0E
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 `Except`
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-2-12 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 1-4-12 oc bracing.
JOINTS
1 Brace at Jt(s): 19
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
18 =
1513/0-8-0 (min.0-2-0)
14 =
1513/0-8-0 (min.0-2-0)
Max Horz
18 =
525(LC 9)
Max Uplift
18 =
-745(LC 12)
14 =
-745(LC 13)
Max Grav
18 =
1718(LC 20)
14 =
1718(LC21)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=1489/650, 2-3=2388/1393,
3-4=2231/1306,4-5=-2184/1318,
5-6=2036/1309, 8-9=-2036/1309,
9-10=-2184/1318, 10-11=-2231/1306,
11-12=2388/1393, 12-13=-1489/650
BOTCHORD
1-18=793/1618,17-18=-793/1788,
16-17=-578/1679, 15-16=-578/1679,
14-15=-793/1618,13-14=-793/1618
WEBS
9-15=36/399, 11-15=-315/411.
5-17=36/399, 3-17=310/406,
6-19=2076/1385,8-19=-2076/1385,
WEBS
9-15=-36/399, 11-15=315/411,
5-17=-36/399, 3-17=-310/406,
6-19=-2076/1385, 8-19=2076/1385,
2-18=-1830/1430, 12-14=-1830/1430
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces tie MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise
indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Ceiling dead load (5.0 psf) on member(s). 5-6, 8-9.
6-19, 8-19
7) Bottom chord live load (40.0 psf) and additional
bottom chord dead load (0.0 psf) applied only to room.
15-17
8) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 745 lb uplift at
joint 18 and 745 lb uplift at joint 14.
9) Attic room checked for U360 deflection.
LOAD CASE(S)
Standard
Md
8cr6r-Flnu nmes9l¢;e•.ne•kuam mm�(s0sm, sirau l0snrrmwmn[nruul-rasrlurugemauermrn r�e,rp,wmtva,¢dc renks�non.ypx;aararssmrrr�is®.rt.r�,n,nmtdm eu. ads¢ea�irsr+rtnaem.wt
Wus®raedsles ssagsenetWraelgguterdL tsedusg�g[y�syi,�ea�[ssmrvl n:ssl¢mymgr4mmsmscspr�uderlrrk:smd¢p,n:igmsarymrsYtm�dee mim rm:tgmal¢nemeear,uielat rrksgemvaxc usrusausc savtiar Anthony T. Tom III, P.E.
law,
t
MeudfasTmsMealteitlallsaernryua:liryddagne5lsd»dssA¢¢degdnaelntfol0-:¢tr,6aenduldaeaC,@ea(¢tae6alb1fo1u6dittLlhenmoldaelfigNeryfieOned&Tms;hddagkseTeydeele,edec�¢it¢ysi�Jh�n�nsmldld =8D083
aektigD•dyerrd6draer.sdedu asmoedaa k.Wpi&sdfewss 6a�ar1Mir �e Mmm 5pr&.sdym¢t 50aldcrwdrrl,dguae. lali�¢sae¢�¢a�Tm¢¢talKsd�lrnso:v�n,Tnss onmrq eedlnrsumnanc: �sss 4451 St. Lude Blvd.
':
eanns>ietoE9rreremearyedepem nGrs tjalrxmsmnmd lk.rrm4Dp6jaen is nil, MJt4DdP.,wTun$rmm6sWw d¢ywfu}la¢T1dL+d�a; wrnddndiaTFi Fort Pierce, FL 34046
Copyrigbi02016A-Iioof cusses-Amhonyr.TanboIll,H. 2epradudimalibisdMument,inanyform,isprobihiledwhhaot;hawrittenpmadWaahornklYoolfrosses.AuthonyLTomblll,P.E.
4.
1.
Job
Truss
Truss Type
Oty
Ply
AO129124
69778
A02A
Common
2
1
Job Reference o tional
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44:36 2017 Page 1
ID:IMTa5V VdxJ7_cF0OWg_MyeyiLhV-Z9pvxOkSGnc6HodclbD9HyNO5c9u102W6hVyuwySYMf
8 4-8 16-M 23-7-8 32-0-0
8-4-8 7-7-8 7-7 8 8 4 8
7.00 12 5x8 II
5
4x6 i
4x6
3x6 \\ 4 6 3x6
3 W 7
2x4 II
Z
2
eid
0 16 23 24 15 14 25 12 13 26 11 27 28
6x6 = 4x6 = 6x6 =
3x4 =
"AX10 II in-n-n ii S-n iS-i-n qn-R-in 30-0-1
2x4 II
8
Dead Load Defl. = 1/16 in
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/clef!
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.56
Vert(LL)
-0.04 10-11
>999
360
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.75
Vert(TL)
-0.14 10-11
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.82
Horz(TL)
0.01 10
n/a
n/a
BCDL 10.0
Code FBC20141TP12007
Matrix -MS
Wind(LL)
0.08 10-11
>999
240
Weight: 213 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 `Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-5-2 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS
1 Row at midpt 5-14
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. All bearings 0-8-0.
(Ib) - Max Harz
16=-525(LC 8)
Max Uplift
All uplift 100 lb or less at joint(s)
except16=-324(LC 12). 1 0=-551 (LC 13).
15=491(LC 12), 13=-183(LC 12)
Max Grav
All reactions 250 lb or less at joint(s)
except 16=546(LC 23), 10=1003(LC 20),
15=1112(LC 19), 13=533(LC 19)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-379/203, 4-5=170/344,
5-6=-10251726, 6-7=-1089/697,
7-8=-1229f727, 8-9=-770/256
BOTCHORD
16-23=-424/540, 23-24=424/540,
15-24=-424/540, 14-15=424/540,
14-25=128/377, 13-25=-128/377,
12-13=-128/377, 12-26=-128/377,
11-26=-128/377,11-27=-291f747,
27-28=-2 9 1 f747, 10-28=-291 f747,
9-10=-291 1747
WEBS
5-11=398/692, 7-11=-865/765,
5-14=1008/693, 3-14=-935/810,
WEBS
5-11=-398/692, 7-11=865/765,
5-14=-10081693, 3-14=935/810,
2-16=-797/772, 8-10=956/874
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.0psf; BCDL=S.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
4) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-M tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.Opsf.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 324 lb uplift at
joint 16, 551 lb uplift at joint 10, 491 lb uplift at joint 15
and 183 lb uplift at joint 13.
LOAD CASE(S)
Standard
va,�t-naR,ss�guf�.rv�411CCfi1645•Sh16;6fl3tII7Yst!➢sUlittlS(OfsCY"IOrit)i![67S.ICeuEerhmlertteeu�µmomalndrh:u�slnnh:ipOrtxq{IC�md6:sdsoryl.fulaC1,11.t�.mnSlmtduene WevCxalsm2elarteR0.e.it
WtrtmwIltitmaI ...lhrttetoouseed.iu.t:esem�[qa7[wskmts6p�n;mss�n�IDi:�rcm,®sar�edmfnt:eudvgo resr atq�aetra�sd�shper,n:ege�en�meme.�>aL tktevp.cuaFen:,letaluuaescsamae MthonyT. Tornbo III, P.E.
'ae.sedCarimslucryIrditisaemfnUMd4angMO.,dssdnheigrdnheWlemtCalem,6derededdtis�&IG�tafallhiGgoozofirl-Lfkgtmdd6rlCaneryfieimdBtims;hdsralFml'[alldaesghsiddsaiimyrldihaere�nsn3asd 80083'
ae436iC:gecdhYdo.l6nssuNh&IDbnittpsGsmisurarsdnekCSas6Fnald¢IdmeapSQiolCkel,IflnlSSnmrdaeeelxyvadplarlf4lidn eertsrmultanndk6ad�1nc0.ige,TmsCcMtrnennmsumh�n,nos 4451St. Lucie Blvd.
etlemssktall.eesacaryWgnuv�eurymearv%wshsl lblmdcp6 eahE7t�b:UigDtsl�a,oLnsSlmshsme Aoflr�tue. Nagednestaracmndduehtlll. Fort Pierce, FL 34046
(oppigW® 2016A-I tootinsses-lathanyLlombolll,P.L Pepsodurflualthisduamem,iaany him, isprohibbedruhoutibearinenpermi siaohomA-I Yaafynsses-AmhaorHombaIII, P.I.
A
Job
Truss
Truss Type
Qty
Ply
69778
A04
Roof Special
6
1
A0129125
Job Reference (optional)
i Roof i russes, Fon Pierce, FL 34946, aesign@altruss.com Hun: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MTek Industries, Inc. Tue Oct 17 10:44:37 2017 Page 1
ID:IMTa5VWdxJ7_cFOOWg_MyeyiLhV-1 LNHSk1415kzvyCpJlkOpAwVeOSrmXVgKLFVRNySYMe
2-4-0 8-5-13, 13-10-0 16-0-021-8-1 27-10-0 9-8 32-0-0
2-4-0 6-1-14, 543 2-2-0 5-8-1 6-2-0 -1 2-4-0
7.00 12 5x6 =
2x4 II 6
21 20 19 7C 2X4 II 15 12 11
3x4 =
4x4 = 4x4 II 3x12 = 3x4 =
7x8 = 3x4 11
3i6101 II 29-9-0 32-"
2.0-0 t &5.13 13-10-05�-0 1 21-110 27V 271
2.0-0 (i-s1-14 7-7-0 5-5-0
Dead Load Defl. = 3116 in
LOADING(psf)
SPACING-
2-M
CSI.
DEFL.
in (loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.77
Vert(LL)
-0.09 19-20
>999
360
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.96
Vert(TL)
-0.29 16-17
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.55
Horz(TL)
0.06 11
n/a
n/a
BCDL 10.0
Code FBC20141TPI2007
Matrix -MS
Wind(LL)
0.16 19-20
>999
240
Weight: 241 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2 *Except*
B2,B5: 2x4 SP No.3
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-9-5 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing. Except:
10-0-0 oc bracing: 17-19
WEBS
1 Row at midpt 6-17, 8-17
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
21 =
1468/0-8-0 (min. 0-1-12)
11 =
1502/0-8-0 (min. 0-1-12)
Max Horz
21 =
525(LC 9)
Max Uplift
21 =
-757(LC 12)
11 =
-762(LC 13)
Max Grav
21 =
1468(LC 1)
11 =
1502(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=1559/719, 2-3=2246/1316,
3-4=2321/1447, 4-5=2273/1459,
5-6=2520/1699,6-7=-1874/1264,
7-8=1928/1239, 8-9=-2641/1517,
9-10=-350/111
BOTCHORD
1-21=750/1550, 20-21=-750/1550,
5-17=-555/469,16-17=-898/1894,
14-16=-898/1894,13-14=-991/2063,
10-11 =1 99/439
WEBS
2-21 =-1410/1124, 3-20=-475/393,
WEBS
2-21=-1410/1124,3-20=-475/393,
17-20=-638/1388, 6-17=-1189/1837,
8-1 7=-1 1381762, 8-16=0/311,
11-13=-2059/1503, 9-13=2097/1569
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
4) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-" wide will fit between the
bottom chord and any other members.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 757 lb uplift at
joint 21 and 762 lb uplift at joint 11.
LOAD CASE(S)
Standard
ra.,rmm�emRu7mr.ru-cinaams[s;utsirl.m3itlam eorsnesstassasyswa}mwauswutsrmnrmryeevPpegs�t�eue[an[rune<,remny{txa�nr 1.rs�om,u.tduzswsdnissmea.iwnddme,mutt
wlets�.msddessW 1
natar4eleahlesdd nermsosue(u„�usgrEpm[xtn®pmaigromsairvr5aramr[de:wwecsh�nhrrntrytu�trupdaeshra lm:tyaintvtaauir,mnmir�d:yrssaerms,iaysc:nmcer Anthon' nsetmu:ndsutttr:simdMsteatrnmarddaespasdneaNrsnhynria:xrydt,a„R.�o.ra[eer,yocurxwr�o,ve.h4e u,dedd,6e 0C,flelKnehe6:db9ago�n(iOL tle yrimd .dOr lCCal¢efidd.udM1eimx odsralMeeSgdngandnseaWtraysVdiieFsn4nsiWfild
T. Tombo OI, P.E.
ae wfyC-.d 0edn. Oulu $0..44 W1&-fkn s5flesnekandlnlns[CynsTmslnr[ymNn80083
�hditcromhl lY rntC[urruhrnrpdrylr1.30nte@NasmudBNi101 4452 St. Lucie Blvd.
(oppi¢t D fi116 A -I Aoat frosin-AatbonyL lambo lli, P.t. Reprodadim of this domment,in any form, is prohibAed rris munbe mfiteo permissianfro®Ad RoofTmsses-Acthooy r. famha cif, PE Fort Pierce, FL 34946
A.
Job
Truss
Truss Type
Qty
Ply
A0129126
69778
A05
Hip
1
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MTek Industries, Inc. Tue Oct 17 10:44:38 2017 Page 1
ID:IMTaSW VdxJ7_cF0OWg_MyeyiLhV-VYxfM4mioPsgW6n?tOFdMNShkPoQVuyp27_3zpySYMd
2-0-0 , &5-13 i 13-10-0 15-"17-0-0 , 22-5-0 27-10-0 i 29-0-0i 32-0-0 i
2-0-0 6-1-14 5-4-3 -2 2-0-0 5-5-0 5.5-0 s1-10-0r 2'. r
7.00 12 5x8 -�, Sx6
3x6 11 F 7
22 21 20 to 318 = 16 1312
3x10 I 4x4 = 4x4 11 3x12 = 3x4 =
3x4 = 6x8 = 4x4 it
24-0 -0 32-M
2-0-0 8-5-13 1310-0 14 4-0t7-0-0 27-0 0 27A 340-0
2-0-0 6-1-14 5-0-3 0 2-0-0 10..I, 0
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
L/d
TCLL
20.0
Plate Grip DOL
1.25
TC 0.75
Vert(LL)
-0.13 15-17
>999
360
TCDL
16.0
Lumber DOL
1.25
BC 0.94
Vert(TL)
-0.34 15-17
>958
240
BCLL
0.0
Rep Stress Incr
YES
WB 0.92
Horz(TL)
0.07 12
n/a
n/a
BCDL
10.0
Code FBC2014/rP12007
Matrix -MS
Wind(LL)
0.16 20-21
>999
240
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2 *Except*
B2,B5: 2x4 SP No.3
WEBS 2x4 SP No.3 `Except'
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-10-15 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing. Except
10-0-0 oc bracing: 18-20
MTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
22 =
1467/0-8-0 (min. 0-1-12)
12 =
1503/0-8-0 (min. 0-1-12)
Max Horz
22 =
494(LC 9)
Max Uplift
22 =
-750(LC 12)
12 =
-749(LC 13)
Max Grav
22 =
1467(LC 1)
12 =
1503(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1496/735, 2-3=-2172/1335,
3-4=-2212/1466, 4-5=-2174/1483,
5-6=2430/1734,6-7=-1925/1360,
7-8=2084/1413, 8-9=-2133/1386,
9-1 0=-2564/1645, 10-11 =-345/150
BOT CHORD
1-22=766/1489, 21-22=-766/1489,
20-21=138/318, 5-18=-613/498,
17-18=-453/1189, 15-17=-1023/1856,
14-15=-1056/2079, 12-13=-327/32,
11-12=279/389
WEBS
2-22=-1386/1130,3-21=-427/397,
18-21=-639/1192,6-18=-835/1081,
WEBS
2-22=-1386/1130, 3-21=-427/397,
18-21=-639/1192, 6-18=-835/1081,
6-17=-212/359,7-17=347/681,
12-14=-1879/1551, 10-14=-1935/1619,
9-17=-9067752
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=S.Opsf, BCDL=S.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 750 lb uplift at
joint 22 and 749 lb uplift at joint 12.
LOAD CASE(S)
Standard
Dead Load Defl. = 3116 in
PLATES GRIP
MT20 244/190
Weight: 252 lb FT = 20%
YeFbt�FlevamgOrrerinru'llmi tlESSS(Y,iej.eli3d1 I0Y56L1f6;IIC6[OfIOYj WTd)ilriceu�uurma mnrew��amcwm[mcnm:rnccmr�=eme.igpl4'iWNSMarl.fo:laO,lEle'�naShrtamnv Cehutlmia cr7eenRe lCU,u11 '.
Wicesmas pimcskl seuetwra.;wase stt asrrusuhs�{u,sreaesE<sinecran�rmlcgRrmsmcc,�camcpas:mcday„rigmrwwarrnsesyaaoesro¢elmcsstcma[�ruony.otnmt.r:es:�m,.ac�ear mtiwu umatar Anthony T. Tombo III, P.E.
' �2ar�cTsm�ws.arcnsmrs�nforamso,.ss.rye,urseessodgscsco-:r»uyosssr,hesssesaansaesarse[rmum�lr�sdssdminsenmaaasmns=eryesorssaasr�cs,sasro[essay,crags.us+am.sslbsrycsdtssmsssrsscuartta =80083
mdaryosp du�m.s0easseasaamtoerdaspcse:ndpas:a�r2egrsctaut7asaenpsurssue:nrsemaumsaacedrsmpua�mt�asasncpvuaesn[twcassuns ,lssu��srq, dtncsvmnau:sass 4451 St. Lucie Blvd.
sOsrMsk6a11re;adadspaderuh ghtlrunsshnhellit TOWDOfefgbemu[OtMMOIgPssyx,,erltnsl7NsBdiaOur erlr¢r.2atdednivmesdblibIsl Fort Pierce, FL 34946
(apyridht ®1UI6 A -I Aoollmsses-AntbonyLTambo lB, P.E, Aeptodostioe of this demment,in a yfdrm, is proh;Ehed ismintthe milten permission from A -I loo frassn-hisbo syL l ombo lll, P.E.
Job
Truss
Truss Type
Ply
69778
A06
Hip
�Qty
1
1
A0129127
Job Reference (optional)
Al of Trusses, Fort Pierce, FL 34946, design@al truss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44:39 2017 Page 1
ID:IMTa5W VdxJ7_cF0OWg_MyeyiLhV-zkV1 ZQnFP_hBGMBQjmsub?wUpALETjyofkcVFySYMc
79-3 13 I 19-" 27-10-0 -2-0-0
2
21-0 -0-0 110-0 2
6x6 i 6x8
Dead Load Deft. =1/8 in
19
18 17 1O 4x6 =
129 8
3x4 = 3x10 11
4x4 = 4x4 11 3x4 —
3x4 11 3x8 =
8x8 =
3x4 II
294ft103Fd-0-0
i 2-0.02.4r(1
7-9-3
14A-0 19-0-0
97-1
27ri0-0 3q-0-0
' 2-0-00W0
SS•3
0-6-13 t W.
tgd-0
0 0 21.
1-10.0
Plate Offsets (X,Y)— [1:Edge,0-0-41, [4:0-2-4,0-2-81,
[6:0-1-8,0-2-01, [10:0-M,0-2-121, [15:0-5-8,0-4-01
LOADING (pso
SPACING-
2-M
CSI.
DEFL,
in (loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC . 0.49
Vert(LL)
-0.08 11-13
>999
360
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.83
Vert(TL)
-0.22 11-13
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.44
Horz(TL)
0.10 8
n/a
n/a
BCDL 10.0
Code FBC20147rP12007
Matrix -MS
Wind(LL)
0.12 17-18
>999
240
Weight: 229 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP 2400F 2.0E *Except*
T2: 2x6 SP No.2
WEBS
BOT CHORD 2x6 SP No.2 *Except*
2-19=-1364/1134, 3-18=385/387,
B2,B6: 2x4 SP No.3
4-13=-270/335, 5-13=-92/421,
WEBS 2x4 SP No.3 *Except*
8-10=-2376/1997, 6-10=-2268/1947,
W1: 2x6 SP No.2
15-18=-631/1196, 3-15=-181/307
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-10-0 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 6-0-0 oc bracing. Except:
10-0-0 oc bracing: 15-17
WEBS
1 Raw at midpt 4-13
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation uide.
REACTIONS. (lb/size)
19 =
147110-8-0 (min.0-1-12)
8 =
1509/0-8-0 (min.0-1-12)
Max Harz
19 =
429(LC 11)
Max Uplift
19 =
-720(LC 12)
8 =
-732(LC 13)
Max Grav
19 =
1471(LC 1)
8 =
1509(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOP CHORD
1-2=-1338f721, 2-3=2002/1320,
3-4=-2031 /1488, 4-5=1955/1484,
5-6=-2074/1413
BOT CHORD
1-19=756/1345, 18-19=-756/1376,
4-15=-181/456, 15-26=657/1395,
14-26=-657/1395,13-14=-657/1395,
13-27=-697/1341, 11-27=-697/1341,
10-11=-568/1478, 7-8=-296/414
WEBS
2-19=-1364/1134, 3-18=385/387,
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf,, BCDL=S.Opsf, h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members, with BCDL =
I O.Opsf.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 720 Ib uplift at
joint 19 and 732 lb uplift at joint 8.
LOAD CASE(S)
Standard
taar,g•n� eu�tynn. ru'4110 F nSS S(50IO jnn9ll I0Y56 �t0 0G4(aS 0Y'l fYjtrrWi'ira6YE6f 6 n 1uCrkGppcdmv(rt lw4rnais rnn Cnfr,Onry(d jdW kevrLkrL N,rF.ld ma skCtda, m kno alnalx Cddn a, iC0 Wr
Iel,tr�ardmssfdlktadkrge lgtuknft as,torso:�t, ssu.,s�skgoeer; n:smreaport,gmsau®,e, rdminre:awega:e:opraps�tagmrmtsaya�ewptms kre�nrxmpuir.ntn mt. tatnq,—wt.. uaer msuiuc s,actuq ',. Anthony T. Tombo 111, P.E.
Mnedrtslmsdryt�e0:mpn�yd1h0—.&0+xheenadgexn�:w�rnn. ,eaenneaosaaeixmr.b�sF admml.rsrq-d0,10adM.1.911&T—Wdiykuuys�m.earnwnn:r IAw.kean rsnaapd s80083
n, ka6gl)! iOrn1 kde3r. l9ahs OWN 1000 Man M'dM e,rdaenl6rrssdpitu,. Irsl iBurs@,regnu�Tdn W @tits,ItNnns t.�vs,a,Tms gait,tgrceenlrrtss {4nhDrn�Nns : 4451 5t. Lude Blvd.
mmstasasr,s�amt�cagnn.egyo9remsin,n,tttann0nwkp„aee,rakn�kn�;uuustvnupad.yW A0gW I m,samutelru_
(opyrighl m t016 Ad Yaol irvsses-Aathooy LTanho lll,P.F. &tpedomin afthis duameat, in any krm,is pro60&d eahootth whtenjumissioe from A -I taaff ass:s-AmboayT.Tomb III, P.E. fort Pierce, FL 34946
Job
Truss
Truss Type
Qty
Ply
A0129128
69778
A07
Hip
1
1
Job Reference (optional)
Al Root Trusses, Fort Pierce, FL 34946, design(a)altruss.com Run: B.12U s Aug 1B 2Ul / Print: B.12U S AUg 16 •LU1 / MI I eK Industries, Inc. I ue Uct 1 / 1U:44:38 2Ul i Pagel
I D:IMTa5W VdxJ7_cF0OWg_MyeyiLhV-zkV1 ZQnKZi_hBGMBQjmsub?sgpF9ERJyofkcVFySYMc
r 2.4-0 i 11-0-0 i 21-M i 29-8-0 ! 32-0-0 i
2.4.0 8-8-0 10-0-0 8-8-0 2.40
7x8 i
5x6
Dead Load Defl. = 1/16 in
7.00 12
3x811
\\
3x611
o
01
�•
�� 6
0
toj
__....
1�
0
d
12 19
11
20
7x6=
3x10 ii
3x10 11
2x4 11
910
8
21
7 3x4 =
4x4 =
46 =
32-0-0
i 2-0-0 2rdr0 11-0-0
i 15E-0
! 21-0-0
_ _ _ s
29-5-0
34-0-0 i
2-0-0 0 8-&0
a-0-0
5-fi-0
9-8-0
os4b 2-0-0 !
Plate Offsets (X Y)— [4:0-2-8 0-3-8] [6:0-1-4 Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/defl
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.73
Vert(LL)
-0.04 11-12
>999
360
MT20
244/190
TCDL 16.0
Lumber DOL 1.25
BC 0.46
Vert(TL)
-0.11 11-12
>999
240
BCLL 0.0
Rep Stress Incr YES
WB 0.53
Horz(TL)
0.02 7
n/a
n/a
BCDL 10.0
Code FBC2014frP12007
Matrix -MS
Wind(LL)
0.05 11
>999
240
Weight: 198 Ib
FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
Wi: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-1-13 oc
pudins.
BOTCHORD
Rigid ceiling directly applied or 6-M oc bracing.
WEBS
1 Row at midpt 3-8
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. All bearings 14-6-0 except at --length)
12=0-8-0, 10=0-3-8.
(lb) - Max Horz
12=-363(LC 10)
Max Uplift
All uplift 100 lb or less at joint(s) 10
except 12=-646(LC 12), 8=-588(LC 9),
7=-607(LC 13)
Max Grav
All reactions 250 lb or less at joint(s)
10 except 12=1078(LC 19), 8=1234(LC 2),
7=807(LC 20)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-643/255, 2-3=1250/915,
3-4=775/580, 4-5=-751/465
BOT CHORD
1-12=-344/660,12-19=-386/783,
11-19=386/783, 11-20=-385/790,
10-20=385/790, 9-10=-385/790,
8-9=385/790
WEBS
2-12=-1506/1348.3-11=0/331,
3-8=-783/592, 4-8=-659/706,
5-7=-1378/1220
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=30ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.Opsf.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) 10 except (jt=lb) 12=646, 8=568, 7=607.
LOAD CASE(S)
Standard
iacxq•flrfsf:agg4lreiei6r'tJ n1:IlOSk'>('SSIIQ'y FJtlLL ifttGtWEriiEliS(S31cd1(i7!iI'I1:sROS�OtYiAI'htm. terhkgtEnrstusaiseetedtlw Rs(rtss[z!ip�ahrS7GPtad6lh9u!1.':eedo66ti.U(nesn SSMEdaeeu Gisr; r�neiu mxDnSa itQ, edr
Mi:'et tfm Jd(Mls sh2NnNta6r SD14kd�4ttS+nWJp Egmai-b!(rr�y+f+i'gMStCfl6EjIGGiF%gMipil+jhraiQt/dei:.wltc}vterfq;tirma�ll bf kfCES�}i i�CB1iajilLAl ipifpW r36rth, rttulFl�.'k MSljttSlsspGT:.Ii1TsElilr".F.f, {X1r9PaF( Anthony T. Tonibo 111, P.E.
adrudM+IrrnMtgt ldyairnrr{tt:il ryi�0�ar:lifvtfttd�bdryWvdk;es�e,Ghr�"uElkif'NMCI10dkeesiraeNRll. #80083
RtEdtilrteApe ulrQLifYr. iQmssduimMt:ladlxrnyzs e{pk'wst6aEa9gGalueCS:kJ �ac�u!t(S�ptR9slEtJissdSWmrbti�[¢4fapsc.dgadav i�!d@usfdf nryac�'+; udlx es #Cfiau6rc,eu,rrrntssary er�-nssu :ena,al+ss 44515t Lucie Blvd.
ata.arawd4lr(ecrdgerlgnti.�orprrrsmn� nKnrtnso:dprerro!3fpu�r s P ,grnSSSjhAhpnvdesYdSry 15cEd#arMasmctSNpSPiI Fort Pierce, FL 34946
lopoil!02016Ad4no!bims-Ant6eeyl.lamioill,P.E hPtodotlionolr6isdotomem.iacoy tcrm,ispniWatishbilIberrirmope issiaahemkilooliroues•Ao!6tayLlemba01,P.L
Job
Truss
Truss Type
Qty
Ply
69778
A08
Hip
1
1
A0129129
Job Reference (optional)
nuu, uuaaas, rocs riears:es, rL 34940, oestgn@arrruss.com Run: ts.1zu s Aug 16 mi r Print: 6.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44:40 2017 Page 1
ID:IMTaSW VdxJ7_cF0OWg_MyeyiLhV-Rw3QmmnyKO6XmPxN_RH5RoY5xDedzvb6I JTA1 hySYMb
15-ID-0 232-0 29-M 32-0-D
2-0-0 6-8-0 6-10-0 7-2-0 6-8-0 2-0-0
7x8 i
3x6 11
5x8 =
3x4 =
3x10 11 2x4 II 4x6 = 6x8 = 4x6 = 2x4 11 3x10 11 3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.51
Vert(LL)
0.08
9-11
>999
240
MT20 2441190
TCDL 16.0
Lumber DOL
1.25
BC 0.31
Vert(TL)
-0.04
9-11
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.40
Horz(TL)
-0.01
8
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
Matrix -MS
Weight: 208 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 9-10-6 oc bracing.
WEBS
1 Row at midpt 3-11, 5-11
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
14 =
665/0-8-0 (min. 0-1-8)
11 =
1596/0-8-0 (min. 0-1-14)
8 =
683/0-8-0 (min. 0-1-8)
Max Horz
14 =
-297(LC 10)
Max Uplift
14 =
-478(LC 12)
11 =
-1185(LC 9)
8 =
-594(LC 8)
Max Grav
14 =
728(LC 19)
11 =
1596(LC 1)
8 =
693(LC 24)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=261/33, 2-3=-635/310, 3-4=-134/441,
4-5=134/441, 5-6=-553/934,
6-7=-1801410
BOT CHORD
1-14=-47/264, 14-21 =-1 73/409,
13-21=173/409, 12-13=-171/415,
11-12=171/415, 10-11=-437/216,
9-1 0=-437/216, 9-22=-419/21 1,
8-22=-419/211, 7-8=-419/211
WEBS
2-14=-1053/902, 3-11=-691/578,
WEBS
2-14=-1053/902, 3-11=-691/578,
4-11=-588/807, 5-11=-711/1329,
5-9=-672/254, 6-8=-1048/970
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opst BCDL=S.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed; porch right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10,,p psf bottom
chord live load nonconcurrent with any other live
loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.Opsf.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except (jt=lb) 14=478, 11=1185. 8=594.
LOAD CASE(S)
Standard
e�,u'-remeupryme■ne�I181HI rsMu(rs ursasu7Ymnsnsasrou(rcrr}uua>!(uw:sr(wrmryra,i�pa�anmmseenncrn„asr,on.�poGlmrnesa r.Int;m,rl(aen,smseanru¢dnetmn„axsmrt,sco.n((
wtetmssae, lltln sidlk,se(fametoe1sre,dill„irasona(,9(i,,<.reavht,uy n:,e�uagID;rq,ean o,e,ra.,anepntumaay,.waurmpaamrscae snq,asemf,rms(qm,eamtogni(,ain mr rvkvpaaoleas, adn(u,(ouc swduar pmmonY T. Tombo Ill, P.E.
6ao,da. I
' m2dt~:,ims6rmilddxllsmn,nnaaaide a arfto.,ds, ,adq,dnm(awyg::.va,useua,aria,aLrte(ttnrratnlswgnr,drrrLneyp„aria,mow�e:u.uaa,rms;tra,rq�agd.m.;mrm.nikn�rsea;nurt:M,w;yd 380083
9e Wfml9:stgnded,s'edRUM& M d
a Dyrt6arnlpief¢nd(k WfeiG�aededehidaa,amQ[971sii;Fsely Sx —d—Algr ad Pill- IPFI eafm,H,rtgns�ldas dh6,sdfebnsLsiPs,Tnu knit (gieannns,Fnshann,dm
a9awtsekBsdlrrtanearye:dap,anvcg fydlams ft,AAIhrrrs(kdn rsltr„ IsF7rd, h1lal g,dlw,.TL Sld.b1Y,a dayWiy. as.brine! asssv, a ldsdsrRi- 4451 St. Lucie Blvd.
Upyrigbt 0 2016 Ad Raalirasses-AmbonyT.Tambolll, P.L Repsadumin alt6is dommem, in any (atm, Is probibbed rb6ounbe nfieo peruissiaotrda A -I Paalimssss-dat600TL lamba lll,P.I. Fort Pierce, FL 34046
Job
Truss
Truss Type
Qry
Ply
A0129130
69778
A09
Hip Girder
1
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.cem
L1-3_n
Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44:42 2017 Page 1
ID:IMTa5WVdxJ7_cFOOWg_MyeyiLhV-NJAACRpDsdNF?14m6rJZWDdRcl FzRmaPUdyG6aySYMZ
Dead Load DeB. = 1/16 in
3x4 =
3x6 11 2x4 II 4x6 = 8x12 = 46 = 2x4 11 3x8 11 3x4 =
LOADING (psf)
SPACING-
2-M
TCLL
20.0
Plate Grip DOL
1.25
TCDL
16.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
NO
BCDL
10.0
Code FBC20141TPI2007
LUMBER -
TOP CHORD 2x6 SP No.2 *Except*
T2,T3: 2x6 SP 240OF 2.0E
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 `Except`
W1: 2x6 SP No.2, W4: 2x8 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 6-6-12 oc bracing.
WEBS
1 Row at midpt 3-11. 5-11
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
14 =
669/0-M (min. 0-1-8)
11 =
2183/0-M (min. 0-3-4)
8 =
694/0-8-0 (min. 0-1-8)
Max Harz
14 =
-232(LC 4)
Max Uplift
14 =
-591(LC 8)
11 =
-3404(LC 5)
8 =
-934(LC 4)
Max Grav
14 =
836(LC 40)
11 =
2734(LC 43)
8 =
701(LC 20)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD -
1-2=-566/316, 2-3=-716/488,
3-21=-850/841, 21-22=850/841,
22-23=-850/841, 23-24=850/841,
4-24=850/841, 4-25=-850/841,
25-26=-850/841, 26-27=-850/841,
27-28=850/841, 5-28=-850/841,
5-6=-480/1081, 6-7=409/848
BOT CHORD
1-14=-285/571,13-14=-404/689,
13-29=401/701, 29-30=-4011701,
CSI.
DEFL.
in
(loc)
I/deft
Ud
TC 0.50
Vert(LL)
0.30
9-11
>550
240
BC 0.51
Vert(TL)
0.26
9-11
>627
180
WB 0.62
Horz(TL)
-0.02
8
n/a
n/a
Matrix -MS
BOTCHORD
1-14=-285/571, 13-14=404/689,
13-29=-4011701, 29-30=-401 /701,
12-30=-401 f701, 12-31=-401 /701,
31-32=-4017701,11-32=-4017701,
11-33=-844/416, 33-34=-844/416,
10-34=844/416, 10-35=-844/416,
35-36=-844/416, 9-36=-844/416,
8-9=-826/414, 7-8=-826/414
WEBS
2-14=-601/454, 3-13=-20/343,
3-11=-1379/1372,4-11=-1262/1528,
5-11=-1265/1974, 5-9=-553/264,
6-8=-462/672
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph: TCDL=5.Opsf; BCDL=5.Opsf; h=30ft:
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; porch right exposed; Lumber DOL=1.60
plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) All plates are MT20 plates unless otherwise
indicated.
5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
6) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except Qt=lb) 14=591. 11=3404, 8=934.
PLATES GRIP
MT20 244/190
MT20HS 187/143
Weight: 211 lb FT = 20%
8) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 455
lb down and 514 lb up at 7-0-0, 238 lb down and 211
lb up at 9-0-12, 238 lb down and 211 lb up at 11-0-12
, 238 lb down and 211 lb up at 13-0-12, 238 lb down
and 211 lb up at 15-0-12, 228 lb down and 211 lb up
at 16-11-4, 228 lb down and 211 lb up at 18-11-4,
228 Ito down and 211 lb up at 20-11-4, and 228 lb
down and 211 lb up at 22-11-4, and 434 lb down and
521 lb up at 25-0-0 on top chord, and 176 lb down
and 136 lb up at 7-0-0, 59 lb down and 43 lb up at
9-0-12, 59 lb down and 43 lb up at 11-0-12, 59 lb
down and 43 lb up at 13-0-12, 65 lb down and 43 lb
up at 15-0-12, 32 lb down and 140 lb up at 16-11-4,
32 lb down and 140 lb up at 18-11-4, 32 lb down and
140 lb up at 20-11-4, and 32 lb down and 140 lb up at
22-11-4, and 164 lb down and 348 lb up at 24-11-4 on
bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-72, 3-5=-72, 5-7=72, 15-18=-20
Concentrated Loads (lb)
Vert: 3=-92(B) 5=-92(B) 13=56(B) 9=56(B)
21=-56(B) 22=-56(B) 23=-56(B) 24=56(131)
25=-56(B)26=-56(B) 27=-56(B)28=-56(B)
29=-11(B) 30=-1 1 (B) 31 =-1 1 (B) 32=-11(B)
33=-11(B) 34=-11(B) 35=-11(B) 36=11(B)
was). Flaw eftA":-fe*A1runTsms[s(uuu),ROM IMSsODES 11TOMIMMroeean11MAIrhaTat huppm"naamsmsIs ibis ma!marl.Fah m,r.L!demoF. IdnH bliss dfaenndnm,ED,;dr
fbTA-1 rr�d,s stAt!,altaax iCbal!N:L lsaims0:s brms(u.heads!sivaelle,xlnwri67,q�eah®esgtaed�Inkssnedagremsrapnd*Ws4r3t lea,9d0eshpeTm;leTstdat:TDhds,alami. nehsenanatas, k1qudnas,satilq Anthony T. Tombo III, P.E.
' afaedacsTmrfaeirabmeaymiS:InTd9e 0.ar, Fe llndeeAlmml,pSam:k7tarBae,h3e adeddtieQC9,ls(diie kd5r7fvlahalltlt. Ikgrmdd6,IC0algkil.udfleims;hACn3Fe,lly,sRq,,hsWaNluxsildlM@ea3miNiryd =80083
mrdreroespeaeta!saa.IOahssdmetarboalsen as!tr®ndmrtien(,eRedkhKm,aa;rssgsdsrslrfFlaisrue„deaultxissdpHaalNlidxsl,agnbl§esasGaadnsLasD 1,TaaO:p6;aaairnavaddoa,dm: 4451 it. Lucie Blvd.
,nasne htafIretmLdryNryartrnY§II7IvNnlad,d 1hI-WL.bib. b111Mk11fgD,rlpa;aTraattme 6plpa duyb 114 daalWbdlaa; m,-0-1110M. Fort Pierce, FL 34946
(opyripkt d91pl6 A-1 RaolTnssls•Actbooyl. Tanbo Ill,P.f. Reptododian eltbis dotomeas, in any foun, is problhed vabouttka sninen permissianhom A -I RaoTTresses- AnboayT.To®bo III, P.F.
Job
Truss
Truss Type
ty
ply
69778
A10
Hip
T
1
A0129131
�
"' f T F
Job Reference (optional)
0o cusses, art Pierce, FL 34946, design@a I truss.com Run: 8.120 s Aug 16 2017 Pnnt: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10*44:43 2017 Page 1
ID:IMTa5W VdxJ7_cF0OWg_MyeyiLhV-sVkYPngrdxV6dtfytZro3RAdkQaYAHNHigeOySYMY
2-4-0 15-0-0 17-M 23-4-0 29-8-0 32-0-0
2-4-0 6-4-0 6-0-0 2-M 6.4-0 19 2-4-0
7.0012 5x811 5x811
46 i 5 a
17 16 151413 12 11
3x4 =
3x10 11 2)c4 I 4x6 = 2x4 11 3x10 11 3x4 =
Dead Load Deft. = 118 in
24-0
3x4 = 3x4 =
32-0-0
2-041
8$-0
12-10-8
1SQ0 i 17-0-0
23-0-0
29$-0 3
2-"
6-0-0
4-2-8
2-1-8 2.0-0 '
8-0-0
U- 0 -0
0-4-0
2-"
LOADING
(psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
Ud
PLATES GRIP
TCLL
20.0
Plate Grip DOL
1.25
TC 0.41
Vert(LL)
-0.07 12-13
>999
360
MT20 2441190
TCDL
16.0
Lumber DOL
1.25
BC 0.62
Vert(TL)
-0.22 12-13
>780
240
BCLL
0.0
Rep Stress Incr
YES
WB 0.38
Horz(TL)
0.01 11
n/a
n/a
BCDL
10.0
Code FBC2014/rP12007
Matrix -MS
Wind(LL)
0.12 12-13
>999
240
Weight: 229 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing,
Except:
6-0-0 oc bracing: 13-15.
WEBS
1 Row at midpt
3-15, 5-15, 6-13. 8-13
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
17 =
701/0-M (min.0-1-8)
15 =
1456/5-9-0 (min. 0-1-11)
11 =
787/0-8-0 (min.0-1-8)
Max Horz
17 =
494(LC 9)
Max Uplift
17 =
-427(LC 12)
15 =
-620(LC 12)
11 =
-537(LC 13)
Max Grav
17 =
701(LC 1)
15 =
1456(LC 1)
11 =
842(LC 24)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-286/105, 2-3=-667/369,
3-4=-299/324, 4-5=-236/340,
5-6=362/414, 6-7=-263/302,
7-8=-326/292, 8-9=922/534,
9-10=-454/135
BOTCHORD
1-17=-95/302, 16-17=-357/544,
15-16=-357/544, 14-15=-395/498,
13-14=-395/498, 12-13=-1331471,
BOTCHORD
1-17=-95/302, 16-17=-357/544,
15-16=-357/544, 14-15=-395/498,
13-14=-395/498, 12-13=133/471,
11-12=-1331471,10-11=-133/471
WEBS
2-17=-868f792, 3-15=-820/594,
5-15=-527/383, 8-13=-11021777,
8-12=0/293, 9-11=-975/861
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces 8s MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except (jt=lb) 17=427, 15=620, 11=537.
LOAD CASE(S)
Standard
... liurq•fltae nr lrea4ta,at'SJ re.5.T1Ig5kijS01R"yO110et I!ul3iNJGfitiSilr]ICil{'R7!0�1:rN9fis3ElS%1'Mn.tat (Wprrrtswtmufn"Ns Na P pctaigllwj ddsltaml ieaiol&tl01cm R!dtev"L Mudniil 0=i"2tTWff1
. W!a:wrkr esar7ltflN(arxl ersma�axefiaa b erj nprl6GnpnuStnR.ter'u.1dIttRAn:aN1!gnmU(ntp3titnrghth5lpd6ttub,Lnsigiltdmfitl3gnlr,!st4!mt!tta;4ttsu em,,tugc ns,smu'ry AnthonyT.Tombo111,P.E.
' zdntdttrs irnsMtg9dt�abrc p {>=&i' ya!,htxaNmiNt ar,lt Orei&hall¢1al:tttrIT4L lkgrrertldtielmlMalSelir,�d�ernsf,�'siu7�4d"54ia+Fra!asdtrerat ss�lt 3e,ypetiti�td
3t tr'.(ierhsl drmrzc#r. iBnnsulutc@ePflstfnrn2usatp es/Mls4tarOvpssY fd±j6#nCiatll(SGicttisttiitBlclSl;imstrerznbturex!el piduMM!le:vnit ruin-Nudt£iu efaTpuko;w, Inv Dno rgiauet,.vWtaaer,atns #60083
elx�in gneiS!euCMsjerlgu bRhogprdnsnlnL lhlntgestt,fipuxN rgi #t trzTarinipa,a tnssr!sisrOpen dell t�eag, lg�i4aelmr,. m u rtndnlRi. 4451 St Lucie Blvd.
•
Copyrigir05016A-1Hootinsses-Ae!Denyl,lamEnIII, p.E 4pradoui000i!6isdommeat.iaenyrmn,ispraSi6ittdrit6anu6enrirrope!missioefiomk1feoiinssn-Am6enyl.lac6nA!,p.E, Fort Pierce, FL 34946
Job
Truss
Truss Type
Qty
Ply
A0129132
69778
Al
Hip
1
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.cem Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 1710*44:44 2017 Page 1
ID:IMTa5W VdxJ7_cF0OWg_MyeyiLhV-Kilwc7gTOFdzE1 E9DGM1 beinLquZvm5ixxRNATySYMX
r 2-4-0 i 13-0-0 i 19-0-0 29-M 32-0-0
2-41 10.8-0 6-0-0 10-M I 2-4-0
o_
6
7x8 i 5x8
11 'm 10 ' 8 " 7
3x10 = 2x4 II 4x6 = 3x4 = 3x10 =
3x10 II
3x10 II
32-M
Dead Load Dell. =118 in
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defi
Ud
PLATES GRIP
TCLL 20.0
Plate Grip IDOL
1.25
TC 0.48
Vert(LL)
-0.12 10-11
>999
360
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.76
Vert(TL)
-0.27 10-11
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.24
Horz(TL)
0.04 7
n/a
n/a
BCDL 10.0
Code FBC20141TP12007
Matrix -MS
Wind(LL)
0.10 5-10
>999
240
Weight: 200 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP 2400F 2.0E *Except*
T2: 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 `Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-2-4 oc
puriins.
BOT CHORD
Rigid ceiling directly applied or 8-9-2 oc bracing.
WEBS
1 Row at midpt 3-8
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation gi ide.
REACTIONS. (lb/size)
11 = 1472/0-8-0 (min. 0-1-14)
7 = 1472/0-8-0 (min.0-1-13)
Max Horz
11 = 429(LC 9)
Max Uplift
11 =-739(LC 12)
7 =-739(LC 13)
Max Grav
11 = 1570(LC 19)
7 = 1561(LC 20)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=1195/321, 2-3=-1860/1315,
3-4=-1753/1391, 4-5=-1860/1314,
5-6=-1184/321
BOT CHORD
1-11=-603/1256, 11-18=-603/1364,
10-18=-603/1364, 9-10=-601/1371,
8-9=601/1371, 8-19=-602/1244,
7-19=-602/1244, 6-7=-602/1244
WEBS
3-10=0/390, 3-8=-316/318, 4-8=-108/452,
2-11=-2024/1861,5-7=-2025/1861
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf,, BCDL=5.Opsf; h=30ft;
Cat. ll; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom.
chord live load nonconcurrent with any other live
loads.
5) • This truss has been designed for a live load of
20.0psf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members, with BCDL =
10.Opsf.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except at --lb) 11=739, 7=739.
LOAD CASE(S)
Standard
rnug-rtaveam�rn:k,SeYu¢,rctrmss; uu0ry,snau rausermmn¢srwraunerts¢ce¢emauarma raaravt,p�mrwnu�r�:ra,m::c,:�A�.:r{me;�rmrm.Ir.r�te m:r�.rdmt.,sr�nmm:w. e�:,�.�:,m,eme�m¢.�y
WTttcaetIXrp'rhetiAkmeltmsr to¢ro4<etl lsaums¢:s�hrwe(u.sin^thrs> o: ssrnmrral mmsasr emra!e:unilergasr�r»wmaurymr�a r:upanem rm:t<raaae�rwmr,aemml t�s<Wessaarst,4nryw�ius.smamr Anthony T. Tombo lII, P.E.
' d�u:lh:Tms6rottaesrisBemryul..IclddOnn,Pe¢.ult,AmmigemndernitarCa:¢eh2eutlemd6elM&QCdfx4uikACorotraelr4l.itee�mddheN¢WgfienauA&Tms;od,fykdtr�,eraege,uNC�waeheaysidtetsrrermRarttd - t80083
OeG¢Ca1P:4gerallWnfi.t¢m:ssdMu�l¢Cnl ezrmaim mlriertwtArietNSai4 neiSderylAusmmplSJr°15�ellmatSalnTrdeeaeedr dpilcm�lRlteSuttN regavbtoefdQe<rd2rufr0.A�e,TnuoNy tgyeemrna:�naaa,�das. 4451 St. Lude Blvd.
rnrrnu7efmfyrleanr�neernnncytldrmuni::,xKswt�,oeep�gms,ue¢ratru�goeri r,aunrsnesbpuno!ufnarar.ma,¢mvetn,mrmrsadduml. Fort
Pierce, FL 34946
(opyright ®2616 Ad RaolTnsses-AathonyLTomholll,P.L Reptaiurti¢¢ alihis dammeat, in any hrm, is probilitel ruh¢ut the mined petmissiao from 6d taolimises-Amho¢yL T¢mhoIII, PE
Job
Truss
Truss Type
qty
69778
Al2
Hip
1
71'."
A012913Reference
(optional)
f Ruc f trusses, Pori Pierce, FL 34946, aessgn@alIIuss.com Kun: 8.1211 s Aug 18 LU1 f Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44.44 2017 Page 1
ID:IMTa5W VdxJ7_cF00Wg_MyeyiLhV-fCilwc7gTOFdzE1 E9DGM1 beigVgt5vjGixxRNATySYMX
16-0-0 21-0-0 29-8-0 32-M
8-8-0
0
5x6 i
3x4 = 5x6
3x10 = WO 11 3x4 = 46 = 3x4 = 3x10 II WO =
Dead Load Defl. = 318 in
0
ro
0
I97
0
i 2-0-0 2,4-0 11-0-0
21-0-0
29-8-0
324W
30-0-0
z-0-0 oaw 511
10-0-0
a a-0
0 24)-0
Plate Offsets (X,Y)—
[1:0-10-0,0-1-101,[7:0-10-0,0-1-10)
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.92
Vert(LL)
-0.20
9-11
>999
360
MT20 244/190
TCDL 16.0
Lumber DOL 1.25
BC 0.79
Vert(TL)
-0.55
9-11
>598
240
BCLL 0.0
Rep Stress Iner YES
WB 0.42
Horz(TL)
0.05
8
n/a
n/a
BCDL 10.0
Code FBC2014frPI2007
Matrix -MS
Wind(LL)
0.22
9-11
>999
240
Weight: 205 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP N0.2
BOT CHORD 2x6 SP N0.2
WEBS 2x4 SP No.3 `Except`
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 7-5-13 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
12 =
147210-8-0 (min. 0-1-12)
8 =
1472/0-8-0 (min. 0-1-12)
Max Horz
12 =
-363(LC 10)
Max Uplift
12 =
-708(LC 12)
8 =
-708(LC 13)
Max Grav
12 =
1498(LC 2)
8 =
1498(LC 2)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-12341578, 2-3=-1840/1410,
3-4=-1700/1418, 4-5=1700/1418,
5-6=-1840/1410, 6-7=-1234/578
BOT CHORD
1-12=746/1284, 12-19=-746/1291,
11-19=-746/1291, 11-20=926/1428,
10-20=-92611428, 10-21=-926/1428,
9-21=-926/1428, 9-22=-746/1284,
8-22=746/1284, 7-8=-746/1284
WEBS
3-11=-188/510, 4-11=-339/424,
4-9=339/424, 5-9=-187/510,
2-12=-1717/1560, 6-8=1717/1560
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph. (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf, h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) • This truss has been designed for a live load of
20.0psf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.0psf.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except at --lb) 12=708, 8=708.
LOAD CASE(S)
Standard
va>o1-n¢ 1o:E,rrss(:IOUa03u(N:!(mmgss(rsur"awfillwarbra, ¢(nd�rr¢ea,Ennh,P�r.gP�d�,rr�RLE�E.�,I.E.sAu tSkrtldmrtshrcsalminraNm4eCD.¢¢
MansmrmaltmssmsnwfarthMuhmthermsn:vpms-nvriogrms(r;md¢(vron¢it,rUnmE.r:h:grewuraMkain¢uws.ssada� Anthony T.TomboIII, P.E.
' ne rsedsmimshraryWHs;htem;uu}lRid&g.xr,tag.¢iemhnvdgrt¢mkHe10¢vee,hteudeddt4n QCtlr ftCWhr6WhNfs3¢h¢!mL Ete epmdd6e1C6¢l esfcNmE&imx ndAighnteyueepjfera6.nl L-1"htx ruseiromfd =80083
muxlosa� w(snm:.Igsdrs hmnmioo¢(upmus¢(r d rr1(srsdh8s�ma,s(sn;4�n;rnwsm�era�srsesxr�9a �s rrs(tcn esn ¢¢,daundmins;
r9nvfndehvdyr(¢aMrgedgnhnCghsl Ames hnhsi lhrmDNa 6raea is [9sMri3rlggrrl p'd' a (hdEse,inss k:m [gsmdfnn Ymhgvn; wss 4451 St. Lucie Blvd.
pn,¢rn:ssp(ry hen mo;lnIEtr} ign;oderd ie:s ¢r ¢ ddlydkmi.
(opyrig6tiD1016A•IRaolfnsus-AathoayLTomhoIll,P.E. Reprodoaianslits dommear,iaany him, ispfobRailsrhhoutt5eninenpermissianfrom MlRoaffsosses•AindoeyI.To®holli,Irl. Fort Pierce, FL 34946
Job
Truss
Truss Type
Qty
Ply
A0129134
69778
A13
Roof Special
1
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MTek Industries, Inc. Tue Oct 17 10:44:45 2017 Page 1
ID:IMTa5% WdxJ7_cF0OWg_MyeyiLhV-ousJgTr59YfgsBpLn_tG8sFgyECXe4grAaBxjvySYMW
z-4-0 s-0-0 17-0-0 zo-o-0 29-M 32-0-06-8-0 8-0-0 3-0-0 9-8-0 2-4-0
6x6 =
cn,
12 r' 11 9 8
3x4 = 3x10 11 3x4 =
4x6 = 4x4 =
Dead Load Defl. = 7/16 in
o_
oa
7 0
I�
a
3x10 II 300 =
32-M
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 1.00
Vert(LL)
-0.20
9-11
>999
360
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.134
Vert(TL)
-0.64
9-11
>516
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.78
Horz(TL)
0.05
8
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
Matrix -MS
Wind(LL)
0.26
9-11
>999
240
Weight: 204 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 `Except'
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied.
BOTCHORD
Rigid ceiling directly applied or 6-4-11 oc bracing.
WEBS
1 Row at midpt 4-11
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
12 =
1470/0-M (min. 0-1-12)
8 =
1474/0-M (min.0-1-13)
Max Horz
12 =
-394(LC 10)
Max Uplift
12 =
-831(LC 12)
8 =
-727(LC 13)
Max Grav
12 =
1470(LC 1)
8 =
1543(LC 20)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1246/771, 2-3=-1933/1426,
3-4=-1737/1376, 4-5=1998/1510,
5-6=1972/1368, 6-7=-11881462
BOT CHORD
1-1 2=-826/1271, 12-1 9=826/1327.
11-19=-826/1327, 11-20=-1239/1787,
10-20=-1239/1787, 10-21=1239/1787,
9-21=-1239/1787,9-22=-686/1242,
8-22=-686/1242, 7-8=-686/1242
WEBS
2-12=-1439/1228, 3-11=68/473,
4-11=-620/497, 4-9=-1144/1128,
5-9=-866/1195, 6-8=1910/1702
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf, h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.Opsf,
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except Qt=1b) 12=831, 8=727.
LOAD CASE(S)
Standard
a"6141-0.gtlpk.rx'isra:FTMHI3<1n�eR3IPIZLOt0111L4F75lill )S857EtrDWilPfamltohhtipµ 9mvindarutltrnrtRfl;rOnrb;Qg;¢dneWapLrv2aC,lt.rA—W.tdetnsEd'.ftiuMi. thM1.11
fLTst;ldrs st➢krxamae7svnarrdirssirnsgeBga�Eu,�a„es rrr�.n::>anoymargmem®stetmirm;rt:smdayesr�mp�amrytr, rtr rrwg,dma�prmsry�nnemgnry,uiarx-tta:hvpr.,.uscFeaa; udauc ciFinaap Anthony T. Tombo I1I, P.E.
' nenedllsimsFu�td sasesni,�rarryada..R,eea+rana grm�re,rwing,spn,ma,ndrdder�.ar¢casr.FmFau�a�mma.nern ldnrmnm�eala.ndmrn,A�asra��e�.d.rp.�u:,a.airmystrseknymua.ryd =80083
mrarngaa��aunan.rgmrmm��roo�r�;we,rrw„dmu€geaa,stdp�rom�nsq;dg�nrmduu�.rdwreFwwyaguc�rrrladma,,mm,wamrmmtnrco� rnnxpFyi<uurmrsFndwnu,�m 4451 St. Lucie Blvd.
e9ernsrranecsamWcayun.�agd�Eaou une,L r�rnngecp rroeu Fs [ara,srn�y o„�pu,��ms;wz uLeadmrs�mr. loaagdad �w.rm�c adwdizrn>. Fort Pierce, FL 34946
(appig5i d9 7p16 A -I Paaf l'rosses-Amhooyr.lom5o 111,P.E, 9eprolurlin 01t5is documaot,in any farny is probaitzl whhounhe Winn permiWanfram 6-I Paolfrosus. tnt6aoyr.lam50 ill, P.E.
Job
Truss
Truss Type
Qty
Ply
69778
A14
Roof Special Girder
1
1
A0129135
Job Reference (optional)
At Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MTek Industries, Inc. Tue Oct 17 10.44:46 2017 Page 1
ID:IMTaSW VdxJ7_cF0OWg_MyeyiLhV-G4Qh1 psjwsthUKOXLhOVh3o0oeboNU 1_PEwUFLySYMV
7-M , 15-0-0 21-0-0 25-0-0 29-8-0 32-M ,
2-4-0 U B-0-0 "I 5-0-1 4-8-0 2-0-0
5x6 =
Dead Load Defl. = 3/16 in
15 14 13 4x6 = 3x8 = 3x8 II 3x6 =
3x4 = 48 =
32-M
LOADING (psf)
SPACING-
2-0-0
CS'.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DO L
1.25
TC 0.93
Vert(LL)
0.28
9-10
>833
240
MT20 2441190
TCDL 16.0
Lumber DOL
1.25
BC 0.65
Vert(TL)
-0.39
9-10
>595
180
BCLL 0.0
Rep Stress Incr
NO
WB 0.97
Horz(TL)
0.02
9
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
Matrix -MS
Weight: 216 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP 2400F 2.0E
WEBS 2x4 SP No.3 `Except`
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-8-6 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS
1 Row at micipt 3-12
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. All bearings 8-8-0 except at --length)
9=0-8-0, 13=0-3-8.
(lb) - Max Horz
15=394(LC 4)
Max Uplift
All uplift 100 lb or less at joint(s)
except 15=-314(LC 27). 14=-1745(LC 8),
9=1464(LC 9), 13=-410(LC 8)
Max Grav
All reactions 250 lb or less atjoint(s)
except 15=333(LC 15), 14=2110(LC 34),
9=2072(LC 34), 13=649(LC 34)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-236/371, 2-3=-195/481,
3-22=-1980/1623, 22-23=-1980/1623,
23-24=-1980/1623, 4-24=-1980/1623,
4-5=-1739/1310, 5-6=-1638/1281,
6-7=-1909/1350, 7-8=1688/1151
BOT CHORD
1-15=-308/266, 14-15=-529/501,
13-14=-607/564, 13-25=-607/564,
25-26=607/564, 26-27=607/564,
12-27=-607/564, 11-12=1530/2129,
10-1 1=-1530/2129,10-28=965/1470,
9-28=-965/1470, 8-9=-965/1470
WEBS
2-15=A44/476, 3-14=2253/1948,
WEBS
2-15=-444/476, 3-14=2253/1948,
3-12=-1860/2672,4-12=-878/720,
4-10=-868/899, 5-1 0=1 022/1283,
6-10=-310/359, 7-9=-894/812
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. Il; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 314 lb uplift at
joint 15, 1745 lb uplift at joint 14, 1464 lb uplift at joint
9 and 410 lb uplift at joint 13.
7) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 461
Ib down and 520 lb up at 7-0-0, 228 lb down and 211
Ib up at 9-0-12, and 238 lb down and 211 lb up at
11-0-12, and 238 lb down and 211 lb up at 13-0-12 on
top chord, and 59 lb down and 43 lb up at 11-0-12, 59
lb down and 43 lb up at 13-0-12, and 764 lb down and
576 lb up at 14-5-4, and 888 lb down and 783 lb up at
25-6-12 on bottom chord. The design/selection of
such connection device(s) is the responsibility of
others.
8) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Standard
Uniform Loads (plf)
Vert: 1-3=-72, 3-4=-72, 4-5=-72, 5-8=-72, 16-19=-20
Concentrated Loads (lb)
Vert: 3=-92(F) 22=-56(F) 23=56(F) 24=-56(F)
25=-11(F)26=-11(F)27=-758(F)28=-727(F)
6trg•flnn�m,N!nriraM'4d177:RgSS.>rSEUB"lNlOrttrtYSttOF.3It�6lEIIC#tig!R'11rri9K"S^EYiAI'lnatn9TMsplew:kcadntiaUnatfrTmsC:sgeCtaeutiitC;dNr:sftegl.lrriolA,PE6tarw3hnrdmru.rssrt�nrasdaS:iCa,ah
WSlaw9, �trss:.7krsdkrxlFEbNsrrrt t: lbamgs sti'p lglpnpa arurr�rd4szrSrs ird eepuerignypaw'itrypshlNpdfitsu¢sLtssigwdrRrt}Datr, tn7rN.TWbsrytns Gu.ttz'rgarCfns,ssMG3r
Anthony T. Tombo ill, P.E.
sdnrditlsrnnkrmtat¢�nerrnlmur'Iivhdilspat,MCmftvdin:Mtr}rdeda{ghsirxn,4rsensmd�7f,2��edcalndl,iLagtHsad7NLrugpwddlSti^IWep'mYrrd#tim4�info4iau6skWegga!IeYmsrdirsh5bktuyu!iii`:d
38Lude
'
iehdturCS;gsselCsrs�.ldwssdwutHPpai6srsa><asdrakmssrmetattg4spaer;.Sdrl8sczsragS ptfiix!!}8lditnmreFleadrngrsnl�itnn,tr!llratxtrngessa§rasulk:indtkr:nspsdpsrInnk:aGga�ewrmsksAcdnaaEns
451
4rtPer Lurie Bivd.
s4nriultemdf(tfCrlr�nlquYwt t}eClaan'srshrl.;NLhss3nip6ynsh60(3e tnYUgCvsgsx,nrnnC(spa&Qstadariaty, ltegildatrMmtennrc4dplrFt,
Fart Pierce, R 34946
Copyrigkl�'t016A-IiaelLetus-Ampeepl.lnm6nI11,Pi Yepsodaaioeoit5irdnnaem,iaamytesaispsai3itrdritSme:1the vrineapttmissiaofiomA-llaolincses-AoSEcerl.Tomb 14P.E
Job
Truss
Truss Type
Qty
Ply
A0129136
69778
B01
Hip Girder
1
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. I ue Oct 17 1U:44:41 2U11
ID:IMTaSW VdxJ7_cF0OWg_MyeyiLhV-kH_3F9tLhA?YSUzkuPvkDHKJb2?p69U8eug 1 ni
2x4 II "4 11 ax's —
2-0-0
10-M
12-8-0 1$-0r0 15-0-0
2 -
2-8-0
5-0-0
2-8_0 4- 2-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.42
Vert(LL)
0.09
8-9
>999 240
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.41
Vert(TL)
0.11
8-9
>999 180
BCLL 0.0
Rep Stress Incr
NO
WB 0.07
Horz(TL)
-0.01
7
n/a n/a
BCDL 10.0
Code FBC2014/TP12007
Matrix -MS
Weight: 94 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 `Except*
WI: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
10 =
420/0-8-0 (min.0-1-8)
7 =
420/0-8-0 (min.0-1-8)
Max Horz
10 =
167(LC 5)
Max Uplift
10 =
-897(LC 5)
7 =
-897(LC 4)
Max Grav
10 =
638(LC 43)
7 =
638(LC 42)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=353/650, 2-3=-395/801,
3-15=-244/668,15-16=-244/668,
4-16=-244/668, 4-5=-394/803,
5-6=353/650
BOT CHORD
1-10=-631/381, 9-10=-705/395,
9-17=-714/394, 17-18=714/394,
8-18=-714/394, 7-8=632/382,
6-7=-632/382
WEBS
2-10=364/516, 5-7=-364/516
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; porch left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 897 lb uplift at
joint 10 and 897 lb uplift at joint 7.
7) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 254
Ib down and 276 lb up at 5-0-0, 157 Ib down and 110
Ib up at 7-0-12, and 157 lb down and 110 lb up at
7-11-4, and 254 lb down and 276 lb up at 10-0-0 on
top chord, and 108 lb down and 247 lb up at 5-0-0, 97
lb up at 7-0-12, and 97 lb up at 7-11-4, and 108 lb
down and 247 lb up at 9-11-4 on bottom chord. The
design/selection of such connection device(s) is the
responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=72, 3-4=-72, 4-6=-72, 1-6=-20
Concentrated Loads (lb)
Vert: 3=106(B) 4=106(B) 9=143(B) 8=143(B)
17=21 (B) 18=21 (B)
smug-neauemr¢IrreH.fie9na;flrmc�rsllltPy5le3u t9msstrnOinCutoflou-IOi3"lussaalltffiIlFir ma se,4h4wc& d"dedan6s Iasi UssrDn.q(rx;;a/ae hnurI.Tak m:tE Win fkr. ldn[R+. a:4rr dn.ur MA nee aa,rdt
161eimsrmrdGssk➢kasdWdtia6hh[dL lsalmsOneetq�s[is,drysOs(spc R�sslpmr167 rgnssds m.ergsamdW{rt;su:ilusv:sm7sespoa:dWr�7a/eapd�sbjeim:teiiastnrcifmulr.n[nIFFs. lkhstpuz¢g:sgl�rzs rerLSest:sildtar Anthony T. Tornbo U1, P.E.
' ataads45rms6rr�tss6e reyuf¢Nrdm[Onn,GU.ui'ses0.mdyMuO:WfmgO:>yea,63audedd(nOt.d[R(dti6�1'tt'tfgdaMilld. hs epmdd6eIDRNosfefdmd&lms.udsCmgsmTmyileep,uA>."di�nllm sisd;leMresgnsiNafd i80083
whir"Nsi.0ft1a.ssassmon,r"oea1axIsMaldrii!Mdfss ea[6-Itsr1ssap;rrss.11iltas:eanyns6raesnfaasdnssmsS!iq.'T-[emsgee,wsn,srtaua,u:nlm... 4451Sit. LucfeBlvd. '
. smnrtsehivllretaatlgsa4gnunaq lydwues unE'a sh 1—h0p Isfwfirma[szLigUs:yex,nuossspuehpse,dra,4arsst masaded1ss; ro urausf ems- Fort Pierce, FL 34946
(opyrighi 07016 Ad Pau(fusses-Aathonyf. Tomb III, PE tepsododin ofthis dommeee, is any form, is probibbed without the when perminionfrom Ad Paeffrosses- Anlhonyl.Tomba 01, P.F.
Job
Truss
Truss Type
Oty
Ply
69778
B02
Hip
1
1
A0129137
Job Reference (optional)
i Roof Trusses, Fort Pierce, FL 34946, aesign@altruss.com stun: 8.120 s Aug 16 2017 Pnnt: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10*44:48 2017 Page 1
3x6 II
5x6 i 5x6
3 4
2x4 II 2x4 II
8-1-8
`t
40
LOADING(psf)
SPACING-
2-M
CSI.
DEFL.
in
(loc)
I/dell
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.45
Vert(LL)
0.06
9
>999
240
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.44
Vert(TL)
-0.05
8-9
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.10
Horz(TL)
-0.00
7
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
Matrix -MS
Weight: 91 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2 *Except*
W2: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
puriins.
BOT CHORD
Rigid ceiling directly applied or 9-10-2 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
10 =
690/0-8-0 (min. 0-1-8)
7 =
690/0-8-0 (min. 0-1-8)
Max Horz
10 =
-229(LC 8)
Max Uplift
10 =
-437(LC 9)
7 =
-437(LC 8)
Max Grav
10 =
690(LC 1)
7 =
690(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-195/370, 2-3=-447/802,
3-4=438f776, 4-5=-447/802,
5-6=195/370
BOTCHORD
1-10=-338/218, 9-10=-338/221,
8-9=-345/219, 7-8=-338/218,
6-7=-338/218
WEBS
2-1O=753/811, 5-7=-753/811
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed; porch left and
right exposed;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 437 lb uplift at
joint 10 and 437 lb uplift at joint 7.
LOAD CASE(S)
Standard
Ninny-Nms!Ilu!gFlrrtM ne'LI Ig:f 110Sffi{'Kiln'j 6R3ll L7tlf 6[UiGIfIGESiJSfeY-INEr')1I¢E�ffifOrYFII'lun re:9rk4ppcdn!drtded!!umisfns!Cr!i�Onr'mt�ondNl�pLfure@,PLrdxmRSk!Itdse.x. Ce4v oteaivakenG@O,Wf
WLtw,�O!!rw!sssdikesetae!iPCase!dil!.Tmsoxa 6iae¢iu,anvlresi�r,9:!¢In�To7!gown®regm!edwrak:wdurhwiy!e:pasdtry6rm4stpdaemd!Tmi{ePmduae@e:dr,oi¢ml rxh:q!�uuru!,udierwreiuc, uast0(. Anthony T. o III, P.E.
Tomb
t
al rsed6sTm!tr¢gtr rtnC!mpm2fnrdre 0.m,tr (h¢d!rAnheegnfun!bTfgO,nnewhddU!NLn!�dnenmeti¢rotralfP4L flm ypmidne@6NerfeN.sed&rmei!drCigkesilig d¢q!.rid!GelsdL•ay sHJkhre:treyiitliyd ;i Tomb
mtr¢soltlpxalfmrt.IgMe!dmnMi0Cn18xpa5mnrpifindHelirat(IrtaslSddld¢¢em;n�P[BFarltiflnlSSle!!deerstbpsdpda!1PFledws@!egndt&!rillne!d�lns!Pr!e,Tnsery!fyeantsm!.ua,rdss g451St. Lucie Blvd.
!n¢.nsr eo ayer«em!Nee�ua. eQry¢vrcroe m!h < to rn, ompay n mfasrwro!�ru ,nunssfd ebga ¢ dorr,mP maµwrdu :! m nam!dnms.
(opydgbtd)t616A.1YoefTosses-Ant600yLTonbol0,p.t.tepsodurivalt%dosomem,inunyfoms,ispioblihedwitboutthemittenpermisdonfromA-IioolTmsses-AnthoeyLTomboIII, p.t. Fort Pierce, FL 34946
Job
Truss
Truss Type
Qty
Ply
A0129138
69778
B03
Common
1
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
4x4
Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44:49 2017 Page 1
ID:I MTa5NNdxJ7_cFOO Wg_Myeyi LhV-gf5pg rucCn FGLo760gxCl iQdPritaOfR5C98sgySYMS
5-6-0 1 11-"
5-6-0 5-"
5x6 =
7.00 12
6 5 4
3x8 11 3x8 = 3x8 Il
Plate Offsets (X Y)—
[1:Edge 0-1-121 [3:Edge 0-1-121
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.53
Vert(LL)
-0.01
5-0
>999
360
MT20 244/190
TCDL 16.0
Lumber DOL 1.25
BC 0.11
Vert(TL)
-0.02
5-0
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.28
Horz(TL)
0.00
4
n/a
n/a
BCDL 10.0
Code FBC2014frP12007
Matrix -MS
Wind(LL)
0.01
5-6
>999
240
Weight: 95 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
6 =
493/Mechanical
4 =
493/Mechanical
Max Horz
6 =
-432(LC 10)
Max Uplift
6 =
-234(LC 12)
4 =
-249(LC 13)
Max Grav
6 =
493(LC 1)
4 =
510(LC 19)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-568/428, 2-3=-553/421,
1-6=-748/535, 3-4=-779/578
BOT CHORD
5-6=-279/317
WEBS
2-5=309/303, 1-5=-255/431,
3-5=-219/374
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed , end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
4)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 234 lb uplift at
joint 6 and 249 lb uplift at joint 4.
LOAD CASE(S)
Standard
tie.;xp•P4rseWr�^;Jrte!u>r9f'4StA=1rViS3{YEUR'y FJnrERtN11r057f1t76rF11Bt1{'W!lt'+F:SA9N•.i^6Srii1'Ixa rolj Nsp reraGas¢ttedWya7tis lnts irYp�naurleClsalW7tpu;1.?sc7oSp,ri tefnuuS4dldue ns. l�rn �ae.N CKNn3a iW,atr
Yi'dtmaArprAsstNhtmdra ke lDEgNmld. AseThssOe:¢rre{�swy y!pa9p5yeeu>8esrtnariQOr�aese az;rp¢eadgtsGsadtsgvexurnrpes°i' Sn&lny+d&dyliTrru i�iaripMl3Dsr!(,afu lflL ihebu3srsyspess.b>:srn as,sshbiar Anthony T. Tombo 111, P.E.
' - rdnedgk rnaWurSslEgbSrrs:pnsiNitrdWOmr,WMu7s n:atrdgWara ;01ro,WwW.ddW7r,9,IKW&1.d Ertigatesr4T141. ruy+rt,ddWVZdeghVvdhinst iylydar.mry^,slaGmuadtra t4eCNC>toysaiis7p) #80083
W eci:GssEadped(naarx-low, rdamdin 1-10oa Mikits 4.insla6Ns uiMis0, WRss 44-, rnao;re rgmevdiml wskarrv.ohn 445nt Lude Blvd.
olnunkrndher Sgeelgs6aAgtrd;rtt�rsisd!rl.ihl.rssOrtip6phss8101£r trzdgrmrye!,a NSSnrtn5VMdtgbft ,i9oFikanlhicsmrle^reihSFFi. Fort Pieree,R 34946
OpYrigll02016A41odTnsus-AmlaoyT.1omtoIII, P.E, tepsadadioeoi0isdoramem,inaoykmisprobAhtilQhoatthe vdireopermissioobomA-IIodhesses-Az1huyMembolilt P.L
Job
Truss
Truss Type
Qty
Ply
69778
B04
Common
1
1
A0129139
Job Reference (optional)
- nuu, ....... , uu rice , raa�a, ucasyul,a t uuss.wm
nun: ts.1-zu s Aug 1rizu1 I runt: 8.121JI s Aug 18 2017 MiTek Industries, Inc. Tue Oct 17 10:44:49 2017 Page 1
ID:IMTa5W VdxJ7_cF0OWg_MyeyiLhV-gf5pgrucCnFGLo760gxCiiQdPdta0fR5C98sgySYMS
120 11-"
5-6-0 5-6-0
5x6 =
7.00 F12
2
04 �/ 43
i
ZZ2
LA
6 5 4
3x8 If 3x8 = 3x8 If
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.53
Vert(LL)
-0.01
5-6
>999
360
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.11
Vert(TL)
-0.02
5-6
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.28
Horz(TL)
0.00
4
n/a
n/a
BCDL 10.0
Code FBC2014frP12007
Matrix -MS
Wind(LL)
0.01
5-6
>999
240
Weight: 95 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP N0.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
puriins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
6 = 493/Mechanical
4 = 493/Mechanical
Max Horz
6 =-432(LC 10)
Max Uplift
6 =-234(LC 12)
4 =-249(LC 13)
Max Grav
6 = 493(LC 1)
4 = 510(LC 19)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-568/428, 2-3=-553/421,
1-6=-748/535, 3-4=-779/578
BOTCHORD
5-6=279/317
WEBS
2-5=-309/303, 1-5=-255/431,
3-5=-219/374
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=S.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
4)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 234 lb uplift at
joint 6 and 249 lb uplift at joint 4.
LOAD CASE(S)
Standard
trant •wma:m�mk.m'Id P7Cu7405S.R('SEllrMy fUtLt itt566Wi3!!g6 rniC{t{'G99�1rG7K;�6Y�1'Mv. tet7rhip tsrxiteel setEastsut>s inst hstprtaui7C�;M� lt2an,T.!es!o0llihMttu tEetlEduttst Ot4it knxue Alt uSt irO, uli
*!titaurN#nsh.'Itn4fafit lP€shnrd Asa ImsMIF4n."Lt,!P0ee/hV"4%'WaMan,-tn mt. iva�,nt pnthon T. Tombo IlI, P.E.
sAttre9kirmhragAtfatevhnga4Earydi!:Dun,da0.sdsu4airdt}wattalildryau�ga,udestaask�f,�e�Ms��dliquleadrFFl iagpa�ftlttxlefat4diredleimtais[utvystuqf,x<trr�eedl5ashGkhayati'1ttl Y
3t tn`tighsfEs¢e+lrnnrt3l. SCmsstlaladel:Pei(rtoSasew'ra§'.mesd6eEcs�htEatLSd8Yh45tmn��(St,'telti9JE?q!alSClmsefuwifaracilESidua, irHlttanMngarr itdtfint8tr;rss0au�xylmsRro &;dxttetirtssL�t6nn.adass #60083
trEltlpd1551iErttiCxl�ttlgNittabt Es OflryPnetti@tL itIL4tPWish¢att1;BPI3t Pit1q r151j3Feat r.+n!Isha FqutNdmlciuE. %9 WAaytIU165m ti t:956gIrIa. 4451 St. Lucre Blvd.
(oPyriP6!02616A-Itoarinaes-Aet6aaYl.IomEolll,PF@produUianolt6itdoomentinoeyfmm,itpmh3rtrd.6oglhertAfopennituanftomA-19oo1Utuet-AeleaYl.Tec5a11!:P.E Fort Pierce, F134946
Job
Truss
Truss Type
Qty
Ply
A0129140
69778
CA
Comer Jack
4
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 1710.44:50 2017 Page 1
ID:IMTa5W VdxJ7_cF0OWg_MyeyiLhV-8sfCtAvEz5N7yyilaXTRrvyw4F6KJXFaKsviO6ySYMR
0-11-11
0-11-11
5.00 12
v
3x4 =
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25 -
TC 0.02
Vert(LL)
0.00 6
Ink
90
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.03
Vert(TL)
-0.00 6
n/r
80
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(TL)
0.00
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
Matrix -MP
Weight: 5 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 0-11-11 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
2 =
88/Mechanical
3 =
O/Mechanical
Max Horz
2 =
84(LC 1)
3 =
89(LC 8)
Max Uplift
2 =
-85(LC 8)
Max Grav
2 =
88(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=321/111
BOT CHORD
1-3=-87/295
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Extedor(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 85 lb uplift at
joint 2.
LOAD CASE(S)
Standard
Be;shr-Fln¢dmgurrtein GeRl le>411asS8j5n1a'}4R3ll 114f 6U7YWil!'iS(gfIOY'rBr�iLLi96t[fieYBl'�al¢�levptecwsdndsKn u?ase¢uCssipUnrier(f�d�rkCar Llrsk 6,tEeslveva Sk¢tdm w. Eed¢dmiusddpBs tCO,sdt
IWlmmiWasok,,dfx cn0liked AsOw Des,e Anthony T. Tombo 1II, P.E.
Zt
ff80083
4451 St. Lude Blvd.
eMnhsMdlre(adepcdrynhn#glfe9lsb¢IushH lklrt;%kopbom is 101fit lelgUnlp¢,srL¢sSdu& d ks tll WO¢el¢a: ¢e¢dsBeelhlRl. t �'Q °J � � Fort Pierce, FL 34946
(oppight 0 2016 A -I loolfrines- Anthocyl.Tombe III, P.I. Rep Wartioo olthis dor issut,in anyform, is pro6litel whhout(Ae enitlenpemissiaa from A-1 loellnsus-Adhnoy l.Tambo 111, V.I.
Job
Truss
Truss Type
Qty
Ply
69778
CAA
Comer Jack
10
1
A0129141
Job Reference (optional)
h, moor , russes, rorc Pierce, rL 14e4b, aessgn(aaivuss.com run; ti.12u s Aug 16 2U1 y runt: 5.12LI s Aug 16 2uT7 MI Iek Industries, Inc. Tue Oct 17 10:44:51 2017 Pagel
ID:IMTa5WVdxJ7_cFOOWg_MyeyiLhV-d2Da4WwskOV a6HV7E_gN7V4ofSg2_VkYWeFwZySYMQ
0-11-11
0-11-11
7.00 Fl2 2
3x4 =
3
0-11-11
0-11-11
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.02
Vert(LL) 0.00 6 n/r 90
MT20 244/190
TCDL 16.0
Lumber DOL 1.25
BC 0.03
Vert(TL) -0.00 6 n/r 80
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(TL) 0.00 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
Matrix -MP
Weight: 6 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
BRACING- LOAD CASE(S)
TOP CHORD Standard
Structural wood sheathing directly applied or 0-11-11 oc
pudins.
BOTCHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
88/Mechanical
3 =
-0/Mechanical
Max Horz
2 =
69(LC 1)
3 =
-69(LC 1)
Max Uplift
2 =
-54(LC 12)
Max Grav
2 =
88(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=252/111
NOTES-
1) Wind: ASCE 7-10; Vult-170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18: MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 54 lb uplift at joint
2.
aadynnu n,�gurmrn,er•auoaf nets{ uual, snau uws s rmmnan esto�rrcr�r7unge(m((wr6� (,s(u,�r�mnm,n(m, nm, (�nkugron.yp��(n,r,n.Tr.t,.(r m,u. umn, um(d.,n, ra,n�.i�m,(ne, aawr
'ihmmmemssmkne(a2,Tcentr,dit,.Tmso,pu( .(wire 6prc7;ee,e�nartg7gn:mmccgm,aw(nt:�ilu�nmtny�aaa(mee(mgrdmem(u(m:e4�eoeemomr,nenmLtseg,mvera rTn(nucsamtm,, Anthony T. Tombo III, P.E.
wtneel P:sTmfM�4i�rhMmim33:lerd6Onq�U.nr,e.raudgesndebl@7U-"•�ga,o8r uaed as,Rid,n(mhlnllzum�utrmmd.6rryim,�d9elBom.,rell.udn,Tnn:mmuytsnlbt. u.gaEmr w4a�ddk@smrmoafid s 80083
n, rrclferMsigerue6skrm,. lmetlnNrou WIN n1Ux rki,¢nr1,v:r-d1kk 16gmandd(Idnadm;i(ffTrdU2lirinnrnG m,d.-dbrrdpWse. inl dduetW rtgnuSlce,ndhtie,Alntuss0:s �ea,Trtn Pe!ig,(gieaaiTm:4ammru:nlots
M,rvhrBhrellrr(xLaarpads(n0nagntliraaes uu5k Ik In;, Defier 6gienls[OTfikUgggoipr,,aTn,strdm 6pradark]for. NaraddAtea,mrsd AhTM1L 44515t. Lucie Blvd.
• Fort Pierce, FL 34946
(oppight®1QI6A-Itaaflnssrs•Aathaayl.TomEaW,P.L 6epsodo:tianolt6isdnmmem,inonpforairprohiEitelrohnmt6enineeprnisrian from A-IYaofi,asses-.ImhoorLTa®3oIII,P.F.
s
Job
Truss
Truss Type
Qty
Ply
AO129142
69778
CJ113
Comer Jack
4
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44:52 2017 Page 1
ID:IMTaSW VdxJ7_cF0OWg_MyeyiLhV-SEnylsxlNdgCFrhhyVvwK2FU3oonRktnAOoS7ySYMP
0-11-11
0-11-11
7.00 F12 2
3x4
3
V
6
,n
0
LOADING (psf)
SPACING-
2-M
CSI.
DEFL.
in (loc)
I/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.03
Vert(LL)
0.00 4
n/r
90
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.03
Vert(TL)
-0.00 4
n/r
80
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(TL)
0.00
n/a
n/a
BCDL 10.0
Code FBC20141TPI2007
Matrix -MP
Weight: 5 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
BRACING- LOAD CASE(S)
TOP CHORD Standard
Structural wood sheathing directly applied or 0-11-11 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 6-M oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
88/Mechanical
3 =
O/Mechanical
Max Horz
2 =
74(LC 1)
3 =
-74(LC 1)
Max Uplift
2 =
-54(LC 12)
Max Grav
2 =
88(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-266/118
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Extedor(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces $ MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3)' This truss has been designed fora live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 54 lb uplift at joint
2.
ter,hstme�epnwru[uoi1mS85r1[[yRKERITUS6[OemL6S(7St0YSICI t[[[ti':[L3Y[lilu¢[nd[tedp[ec4rt,vi,edwnntl,Tn„Csipprb[P�mlM4h,e[T.[uk,®,[tldensSin[ee,i�u[,Lnd-i¢nfdmG:1 .01
WTse—murims,§m s:n,u.V enh1,:dt As IW,O!sge Iqm rla,4d„t1e&.;m,ednMsogrymm,mrvµasdmpc4mwda�.miq,er�v[trylcar<sq,dmempe imclym�a�t[uw[.�aTnt. [semy,enoMe k&[n�nc sa,[dar . Anthony T. Tornbo III, P.E.
Wrurf[h,ims6;mr[,IEh[Is@ehyus3la[d60ner,fiC.enra da�Duh:kO(a[enea,nheumddh,�@,IYNhr[nl'�:ifo[ud,W111LReyprrtldh,[CONJfi:OntdheTmxhd,Cyfudej,l¢e(a,htlJ.:tiaq(tuysidileeens[�wumsa s80083
hr GergO:sigernehre,m,. memsi!INiINICguI rrcensnlptelws,SlSelwfg6egsel Sc4hlder¢eenR[SQidfisf,l It Sfl o{SGl crrda,aesMsmdpisar. IM1Iidhnhereyreut&su[ASn�eclmc0:i,-,s,Tms L:ipEyz,eWIrnstmf�m,rdm 4451 St. Lucie Blvd.
rtMmshdmlMecanmsxaeynh..egyd[canmrhK lh[nn oesw 6[rh[o[dwuaaanper,ntmss[msu[ma dcy [r�saT. ula[rdtrssma; os rsaaudemt. Fort Pierce, FL 34946
(opyright02016A-1RoofTmsses•AetheeyLTodaIII,P.I. Reprobtfluofthisdotomeos,inanyfum,isprohi6hedhithomthemiltenperroissieehooA-IRoofTrones•ArthonyT.TerboIII,P.t.
Job
Truss
Truss Type
Oty
Ply
69778
CJ3
Comer Jack
4
1
A0129143
Job Reference(optional)
, .,,. ��c, , � a•.o , aiyul,a
Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 1710:44:52 2017 Page 1
ID:IMTa5W VdxJ7_cF0OWg_MyeyiLhV-5EnylsxUVidgCFrhhyVvwK2FB3nDnRktnAOoS7ySYMP
2-11-11
2-11-11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/dell
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.04
Vert(LL)
-0.00
4
>999
360
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.07
Vert(TL)
-0.00
4
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(TL)
-0.00
2
n/a
n/a
BCDL 10.0
Code FBC20141fP12007
Matrix -MP
Wind(LL)
0.00
4
>999
240
Weight: 16lb FT=20%
LUMBER -
TOP CHORD 2x6 SP No.2
SOT CHORD 2x6 SP No.2
WEDGE
Left: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-11-11 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation uide.
REACTIONS. (lb/size)
2 =
41/Mechanical
3 =
-20/Mechanical
1 =
247/0-8-0 (min. 0-1-8)
Max Horz
1 =
93(LC 12)
Max Uplift
2 =
-66(LC 12)
3 =
-20(LC 1)
1 =
-110(LC 12)
Max Grav
2 =
41(LC 1)
3 =
11(LC 12)
1 =
247(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=S.Opsf; BCDL=S.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcunent with any other live loads.
3) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding fib lb uplift at
joint 2, 20 lb uplift at joint 3 and 110 lb uplift at joint 1.
LOAD CASE(S)
Standard
rmon.'a fthsSW.@:ramernussaruseysnalr«wsrm,wneecrosTa@cicr�uewsrecurnmrxrar�p�.aA,wades,nm,m„u,g,m..gpary¢mmunRLrulcrNu.rmm,skma:wc�,neA.nrndme,rro.,dr
IbT,tremaxyrhs sknle,se{Wrne iCg4le,dt lsrimsOnge 6ra�aste,5ie¢mTbAa°.n: sealna7iU7rym,Wm,ey6x,dWpdrs(udey¢yryrnrmJ�Lir@i ksipd@emfa Tmslyiddn@el00uly.at¢iFF1. Ikhslpn�,¢rins.lel¢rurCus.s�cSd¢T
' nlredCnimsra bifflib@e nyu,isluid6@.m,&Qnehtdrmd ytdnn:Miq O:spa.h@e udedd&1rb@(Nnrrml w9@yakn{r8-Isle yrmddfi,MD de{fi:id�e d@eTmxmderiy1.9n.d¢ye.tMd¢tiw:d tray sidi h@xreymintiryd Anthony T. Tombo III, P.E.
@, rrlfyWuRaedG:ksdo. Nednsdrd'¢nslPC nib padirenlgrtdmd@elegdy 6cpeena4¢Idn¢elvi(iaQieififFe{Ir fnalSrU n,deaa16r�3dpi{ae.lrlled¢,s@, reyn,d�tnn{/m:edbrnsc0_•spe,Tren rni� 4ynndlnn Ymfa1nn,nlm: 580083
:@um,nMileaadWnayn¢nmjryar¢w,bun,iltern,o,:•g,bp:n,brgrmc,;u�qunp,,abnssrnesusmad,yr ry.marr�ew�ac,nuama{smL - 4451St. Lucie Blvd.
•
(opyright®1QI6A-IYo¢llsosses•Am600yr.Tomhofit, P.L Repradoni¢cathis dw¢meet,i!any him, isprohliredxGhaurtdewrittenpermission from @•IRoof imsses-A¢rhodyLiamh¢III, P.L Fort Plerce, FL 34946
Job
Truss
Truss Type
Qty
Ply
AID129144
69778
CJ3A
Comer Jack
4
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44:53 2017 Page 1
ID:IMTa5WVdxJ7 cF0OWg_MyeyiLhV-ZQLKVCx6G0IhpPQtFf08TYaOFSSzWtk00g7M7RySYMO
2-11-11
2-11-11
3x8 II
2-8-0
2-8-0
2r11-11
-3-1
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES GRIP
TCLL
20.0
Plate Grip DOL
1.25
TC 0.15
Vert(LL)
0.00
5
>999
360
MT20 244/190
TCDL
16.0
Lumber DOL
1.25
BC 0.23
Vert(TL)
0.00
5
>999
240
BCLL
0.0
Rep Stress Incr
YES
WB 0.08
Horz(TL)
0.01
3
n/a
n/a
BCDL
10.0
Code FBC2014frP12007
Matrix -MP
Wind(LL)
-0.00
5
>999
240
Weight: 18 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-11-11 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
3 =
-162/Mechanical
4 =
-244/Mechanical
5 =
67410-8-0 (min. 0-1-8)
Max Horz
5 =
130(LC 12)
Max Uplift
3 =
-162(LC 1)
4 =
-244(LC 1)
5 =
-210(LC 12)
Max Grav
3 =
58(LC 8)
4 =
95(LC 8)
5 =
674(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
WEBS
2-5=-366/639
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=S.Opsf; BCDL=S.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces 8a MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 162 lb uplift at
joint 3, 244 lb uplift atjoint 4 and 210 lb uplift at joint 5.
LOAD CASE(S)
Standard
traseg-nnea�rna.ee�uasffT [s!se1n611 urnussrmmncssraftau [ataqurcasua:uurmat¢riaa rcc rrurafwa,odsrR::e: m,,:rpea;¢aarresrttrcla©:rtrden,santd¢e.0 ro-,:e�.a,r rmrtet[o.uq
WTstrtan pe nsmkesefb re gaale rdi lsatmsu ehp�rpe,sp a2s hs de: sslnegto gam ®:c rearamr esp�:ngr=pa aa�ta�r trvaaaemyruncferer�ae:toanry.vta tt♦Stef<upnaaPus wcsuwuacumaar Anthony T. Tombo 1II, P.E.
n/rudltLnsh, ephadstisa, mimiYfardS, a.x:,hnnelse#l�d nrteh'(at asge,h3e utleAdhe�&IxW1a6�17�illig afselL lkgta+ddfarlUaulryfiellne u'8rr;rss;3dC�gl�rTit.a¢ere,i.siJa¢anl hn¢t sS�hQs re�mi61ar�1 ?BOO83
6r ldr¢g asireradsretrmrr. loofa stlNhmsaa nice prtc9srsnlrrtelemrlfieleaUei(rpsel Sat¢Ides¢mer�l8otdaslaalr(.9rdSlGmsdaeeerbrpj,edpieexe.IPsl t6uese,re5,nsaaifinnddlsrdC:L,ssO:s�pa,iass kshe [egrmedtn,r l�mhena,nless 4451 St. Lucie Blvd.
rea.nsaEaryrtwmrinerennhn 1Ilarnelm:h><mrrmonwhp.u:tarms�L¢tar�pr,oirmstm¢usmeemlmr¢g.MgUadwasmuam,r:ins. Fort Pierce, FL 34946
feppigbi07616A•1RoolTrasses-Aethonyr.TambaIll,P.E. Reproduniaaasb4dorameal,ioanyform,ispfohi6hedWhIauliheaninenpersaissilaohoasA-I lootTrasses-AnthonyT.Tambolll,P.E.
Job
Truss
Truss Type
Qty
Ply
A0129145
69778
CJ3B
Comer Jack
4
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10*44:54 2017 Page 1
ID:IMTa5W VdxJ7_cF0OWg_MyeyiLhV-1 dvi/Yykl JtYRZ?4pNXN?17ZxsR9FKzAFUtvXuySYMN
2-11-11
2-11-11
3x8 II
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TIC 0.16
Vert(LL) 0.00
5
>999
360
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.23
Vert(TL) 0.00
5
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.08
Horz(TL) 0.01
3
n/a
n/a
BCDL 10.0
Code FBC2014/rP12007
Matrix -MP
Wind(LL) -0.00
5
>999
240
Weight: 17 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-11-11 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
-162/Mechanical
4 =
-244/Mechanical
5 =
674/0-8-0 (min. 0-1-8)
Max Horz
5 =
131(LC 12)
Max Uplift
3 =
-162(LC 1)
4 =
-244(LC 1)
5 =
-220(LC 12)
Max Grav
3 =
59(LC 8)
4 =
94(LC 8)
5 =
674(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
WEBS
2-5=-370/647
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed; porch left
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-" tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 162 lb uplift at
joint 3, 244 lb uplift at joint 4 and 220 lb uplift at joint 5.
LOAD CASE(S)
Standard
eesfiT-flemBmgYrrtrOr CuRdr0TF 11a48rYll8j.6li3LL 1.7lIf 6GRN11ClS NSiOYi't4Ter)tll67i•JLbYBrtun terLr6Lpry'rdmn(rccl nY,utl,Tmshilptreeiy{I�)a18e hSgi.fuN ol,rLldnen SkdleM ru ComQmiv:ltetmRe rCD,nit ',
NsTetraAr�:m:allkveiMCrTOCuhrdi lseTmsees¢c himarc[i.e,Sflalry Giiu:.G:s¢In�lOargmeN®mrdardMrcdvdudeghg,4Jm�d'r ir6r3reesi�dtleshy'eTmctgetrdnhelCBulr,¢ta 11Fl. Ikhsgreuafl¢i tmftiu�tA6lPWi Anthony T. Tornbo 11I, P.E.
' ntnedh;TmsfnsghlBsikMrtgsrstleTdda �rnr.ts Cnds uAc,nd sTrsn 5s6nNor avgnu3eudeddfii QCdrIXsdfa6nlhlfmr,ahntRlt lhspmddfirtaenf nrfald.ud&Tms, trdNiq�Tn}s�gausW:di�nl6arsiddhRe mrnsuLd B0083
6rr]roiO:vRercl6�drt.IDMv ufrd'uO:laCa1@e rnoasnlrr..i,fmsdtleb7�GrpralSeShldnmtiw¢IS4rd5:ieelrRl wiSrU eerdamllGxdprlas.lFFlidim Gngnsd�ndedurdc:rnr>esge,ims �:gilysmneTmsunm�rn,ntrss 4451 St. Lucie Blvd.
ieavwhaatryrtanmiyoannY. ryelsmnfi,d,ttarnsdeusremnr7ratxuymiirx,,nTnsspesu�aernrdamtaunrederlmssoresa�nlznu. Fort Pierce, FL 34946
reprrilki02016AdRooTTmses-AathoayT.TonboIII, P,t. Repradomianolihisdommem,iaany form,isproh30edelthoatibevrPoenpermisdaofrom A-IRoelTiess:s-AnihmgT.TonbaIII, P.L
Job
Truss
Truss Type
Qty
Ply
A0129146
69778
CJ3P
Comer Jack
6
1
Job Reference o tional
Al Roof Trusses, Fort Fierce, I•L 34H4b, aesign(agaIuuss.com
Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44:55 2017 Page 1
ID:IMTaSW VdxJ7_cF0OWg_MyeyiLhV-VpTSwuzMod7P3jaGM42cYzfkkGmQ_nEJT8cS3KySYMM
2-11-11 _
2-11-11
,
U8 II
2-8-0
2-8-0
201-11
-3-1
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
IJd
PLATES GRIP
TCLL
20.0
Plate Grip DOL
1.25
TIC 0.15
Vert(LL)
0.00
5
>999
360
MT20 2441190
TCDL
16.0
Lumber DOL
1.25
BC 0.23
Vert(TL)
0.00
5
>999
240
BCLL
0.0
Rep Stress Incr
YES
WB 0.08
Horz(TL)
0.01
3
n/a
n/a
BCDL
10.0
Code FBC2014/TP12007
Matrix -MP
Wind(LL)
-0.00
5
>999
240
Weight: 18 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-11-11 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation nuide.
REACTIONS. (lb/size)
3 =
-162/Mechanical
4 =
-244/Mechanical
5 =
674/0-8-0 (min. 0-1-8)
Max Harz
5 =
130(LC 12)
Max Uplift
3 =
-162(LC 1)
4 =
-244(LC 1)
5 =
-210(LC 12)
Max Grav
3 =
58(LC 8)
4 =
95(LC 8)
5 =
674(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
WEBS
2-5=-366/639
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf, h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed; porch left
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) . This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 162 lb uplift at
joint 3, 244 lb uplift at joint 4 and 210 lb uplift at joint 5.
LOAD CASE(S)
Standard
Ir,nur-n�vewngwrn.a■su•iaso;f nmsa(ula'l rnassra�sermmncsscusrou-arr)ursostru[st•ma r�tmir ��n„amtun,net, rrsncnissmre�0�l;mttu smmrr.rwm,r:.s,�,m,fsersdv,ra wmme.iu mamas ao.nit
taT,Amralipdns"wlikmduraelsaukrails,Tmsorseehreer(u.y,amsrnsa:,�tn�rocnpenms®s�sasdmrsds:vudn�m�mnmamstxdstngedmesuperm,tepednuetrtmt,ctmmtrut,ur,rs,,.rm�tatu,tmncvwaar. Anthony T.TomboIII, P.E.
I udnedRsLmlumrkiCngisd,mpn�Jurd6e0..geaann4eMCdqsmnd,Wtegenge.03euaedd6,�hr¢Ldtlelmlklt�ap,ekm11f4Lheepmdd6,ro4ntrtF:A.911,im,:edfgk.Tnftge,b9A1Wni"lidlkdenstrs,uaff?d -4i80083
n,srnryD!dpwmtGrtea,,. IHedn sdNh G+lagnldzrrtti,rsnl pitdnmdnel,CLg6quslSd,¢Iduo,4atll7l9;psfifktllrmniSWAc,idanistarsdptlQt.IPFtedm,s9,ngn,�lbn sd dustl Felms0.•v�s,U,rsk!gdgswntrnssdvSdnFt,nlm 4451 St. Lucie Blvd.
,temks 4bmdin(wam,poderauntrghdlrcnm 4,dnA lkrnss lhda 4gnwhlgl8,truigaasx+,wLms ssdes fire- d.YW14 to arWndtwxtosmdduduTnl- Fort Pierce, FL 34946
(opyright 0 2016 A -I Roo basses-AathoayL Tombo III, F.F. Repsodo[lion of this dommenl, in anyform, is piablhed withounhe mmen permissiao !son A -I Rool!tosses-Amhonrl.Tombo 111, U,
Job
Truss
Truss Type
Qty
Ply
69778
CJ5
Comer Jack
4
1
A0129147
Job Reference (optional)
on Pierce, FL 34946, oesign@aTnuss.com Run: a.1zu s Aug 16 2017 Print: B.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44:55 2017 Page 1
I D:I MTa5WVdxJ7_cF0O Wg_MyeyiLhV-VpT5wuzMod?P3jaGM42cYzfl DGoS_n RJT8cS3 KySYMM
4-11-11
4-11-11
o �
N
3x6 II
2-0-0 2-4-0 4-11-11
2-M -4 2-7-11
LOADING(psf)
SPACING-
2-M
CSI.
DEFL. in
(loc)
I/deft
L/d
PLATES GRIP
TCLL
20.0
Plate Grip DOL
1.25
TC
0.12
Vert(LL) -0.00
4-5
>999
240
MT20 244/190
TCDL
16.0
Lumber DOL
1.25
BC
0.12
Vert(TL) 0.00
4-5
>999
240
BCLL
0.0 '
Rep Stress Incr
YES
WB
0.07
Horz(TL) -0.02
3
n/a
n/a
BCDL
10.0
Code FBC2014ITP12007
Matrix -MP
Weight: 28 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-11-11 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
42/Mechanical
4 =
-20/Mechanical
5 =
430/0-8-0 (min.0-1-8)
Max Horz
5 =
219(LC 12)
Max Uplift
3 =
-122(LC 12)
4 =
-24(LC 21)
5 =
-138(LC 12)
Max Grav
3 =
96(LC 19)
4 =
37(LC 10)
5 =
430(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-352/258
BOT CHORD
1-5=-272/348
WEBS
2-5=-411/532
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=S.Opsf, BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 122 lb uplift at
joint 3, 24 lb uplift at joint 4 and 138 lb uplift at joint 5.
LOAD CASE(S)
Standard
BrTuT-flat autr,k¢wrh the'1l rggf ll�ESi Yl1fP 6E131hIGlN6[OFOIMlS(7STOYs-fOfiP)ifYn[V06Y[II'In¢Irtdriesi�pmdusul,ulwSswEis fnssGsiPOw�ig(Ip;jadds lsflwrLTw}o�lEedana Skrttdnw. 6ehwdlewlu s�felnRe fCa,sdf
xsTttsnta,rddts slAkwelfor4aTOhLksdd Aseires0ea�6leer(Ie.,ataQ7fcpwrJ, Gs selwv]Irgrspnahoiarremtd6t{rdesWsl wshxrn)raatEry6r�lah�dlkW¢sTmsfgeldwlie1114esry,wtnlFFl. ikltslpm2alQl udGius.sa7shld(
' sslrsedresTmstxmrktyls6etnryhJtltd40nr.,leUru7sndwdelmwfiebtginga,®3ewddlMOLkR(Wsa6anzfulndulTni.ReerpmlofulUOwi fiuwerarrms; r Anthony T80083 [tI,P.E.
nerdlgetsiguud6sa�hr„Nwhs u!ad6�TOh nllkpsCisesnl dewdises a - WEswTm7,slrrm,usldxtisssl!•u¢;sldik�z n�srsniaTel a 60083
Pi'6�w,r>t7mamwpaltdsksslmasuu�erdewynrp�dPummsseee�s,s,wanrd�TwsrraTro:s�gsrrwewltwssua,n�rr,aws
ma.Pis&ray.rmamRaagw�.�wryaTrvmsmtnedtk[nnoeuerryauut,ratsru�mslrnu;wTwustda6yr,cdogsasat masederlmssorwasnramt 4451 St. Lucie Blvd.
(opyright�7glhA-I Raalimsses•AathonyT.Toaholtl,P.E.Reprodurfiaaofthisdonmert,inany (arm, isprohihitelwuhoolthe sdfionpormissieniromA-IRaolTrones-Anthony LToebo10,P.l. Fort Pierce, FL 34946
Job
Truss
Truss Type
Qty
Ply
A0129148
69778
CJSA
Comer Jack
4
1
Jab Reference o tional
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44:66 2017 Page 1
ID:IMTaSW VdxJ7_cF0OWg_MyeyiLhV-z?l T8E_?zx7Ggt9Swoar4ACueg6sjFkTioMObmySYML
4-11-11
4-11-11
3x8 11
Plate Offsets (X Y)—
[1:0-3-6 0-0-121 [1:0-1-7 1-2-131
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/defl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.21
Vert(LL)
-0.01
4
>999
240
MT20 244/190
TCDL 16.0
Lumber DOL 1.25
BC 0.22
Vert(TL)
-0.00
3-7
>999
240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(TL)
-0.01
2
n/a
n/a
BCDL 10.0
Code FBC2014frP12007
Matrix -MP
Weight: 26 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEDGE
Left: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-11-11 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
114/Mechanical
3 =
28/Mechanical
1 =
31010-8-0 (min.0-1-8)
Max Horz
1 =
156(LC 12)
Max Uplift
2 =
-13B(LC 12)
1 =
-141(LC 12)
Max Grav
2 =
114(LC 1)
3 =
59(LC 3)
1 =
310(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; End., GCpi=0.18; MWFRS (envelope)
and C-C Extedor(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 138 lb uplift at
joint 2 and 141 lb uplift at joint 1.
LOAD CASE(S)
Standard
twerny-nm'Rmyk¢rtnev6e'}I COuf n8L15,15,01'j5113111RYSe[01MMISMIDYr Nf:Y}1R67R(MBI'lun leNthilppv-9usnlnd:ofsaGslnssCe9pPnryO[9j®!mComQmheMelnR:IGO,sdr
ILtetmsxardmss�e leueddreeTeeroh N.i 4simsfi:sye [q�e{u,sr�r[sr lfi:so-�x�tmsgmms m.nga.sdmr :shwnse::shtmpxatryara�rsu,dm:m Tm:tgdeaamIDewr,uta mttletnpnn�mcurturr:dcus. ttmt�:dt Anthony T. Tomtro 111, P.E.
al rstdhsTntsbatar4LLfsrhOe nqusiateldhOrur,m Onds �nudgeSuneWt y0n:pe,hle udeddtielC.QstKallie lud�:Iliq:dsa/IFIL Ikegrymldfisf00a1 n1fi:id.sedflrims; hdsi�rnllay slage,hshGtinnitn�ildh@e m�mniiiryd �80083
mu7f ra,sigum[rearOsr.hied:ssdrahmtaendser�s+�adp��:�sdrstraral aa�ew ldsnldrsr�¢Ixjlae,redgmwscl c:mcs ldm�dpn��TFFlitxsas ngnu�mh nl aasdmtnssn:vpa,Tmsu:�pr>;ssemtnssumhss,odm 4451 St. Lucie Blvd.
sMrhsM�zdNs[e0mrywdgnhnmq hdlprnn Onhed lk rn;tDes!p Glaalsl9l8:t:lllq Ot:Isw,ulnu SrtlraGs►widoJ trlliq. Naltrlfid MumulalbdeinL Fort Pierce, FL 34946
Copyright0teldA-Iloof oss:s-AdDayLTarbolit,P.L Reprodualaaafthisduament,hanyform,ispmblbnadwitbouttbeminenpermissionfromAdPoafLnnn-AathoayT.Tonho111,F1,
Job
Truss
Truss Type
Oty
Ply
69778
CJ5P
Comer Jack
6
1
A0129149
Job Reference (optional)
T Rooi Trusses, Pon Pierce, FL svavo, design@aitruss.com Run: 8.12o s Aug 16 201 y Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44:57 2017 Page 1
ID:IMTa5W VdxJ7_cFOOWg_MyeyiLhV-RCarLa?dKEF711 kfUV54dOl5j4T9Si1 cxS5Z8CySYMK
4-11-11
4-11-11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.12
Vert(LL)
0.00
4-5
>999
240
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.15
Vert(TL)
0.00
4-5
>999
180
BCLL 0.0
Rep Stress Incr
YES
WB 0.06
Horz(TL)
-0.02
3
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
Matrix -MP
Weight: 28 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-11-11 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation uide.
REACTIONS. (lb/size)
3 =
42/Mechanical
4 =
-20/Mechanical
5 =
430/0-8-0 (min.0-1-8)
Max Horz
5 =
219(LC 12)
Max Uplift
3 =
-122(LC 12)
4 =
-74(LC 9)
5 =
-143(LC 8)
Max Grav
3 =
92(LC 19)
4 =
10(LC 3)
5 =
430(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-336/260
BOT CHORD
1-5=-272/348
WEBS
2-5=-419/485
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
- and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed; porch left
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
3) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 122 lb uplift at
joint 3, 74 lb uplift at joint 4 and 143 lb uplift at joint 5.
LOAD CASE(S)
Standard
7odst-Flan murky lTnrinEelllD:i t10L6jSFifa'jdn3ll 19Elf6fNDRIDS(DStDYj WlSjtt[[D5tID6Y:IT'pm lerts teilpp dnrnlruletlsutlsfnnLnlpNvy{fIXPpIDek6siT.T¢G®,If.ldere;e Skdldnr m. Ddsn d-mWduGe RD,.11
FHT:trmmpteHsskDknelldmlpl0lesd:t. ,4rlms0age FyNd¢e„Sie tE Detslgmi169tgrtfah sc rvFhvrdMFnh:tHoduSF+vrmgrnFuddithrGelrsipd9e cbFH Trrss leF3tdntLlDDnIF,utnlRL lhh9rysmytnL4et ws1d."'w`t%
Zt
alardksL 1u.1hll,FDDempnhfirydtw,0 ,t.Dun.Ahdysdnde&DFaTDa:pe,h4eutledddrQCWXsdtsEMErilfmtmhdlALNtipuld6rl00udgfnldmdWh.ntNrtF dupdeye,HWW..ik-10dlkkq.witid'��OnyT.TOffIt10III,P.E.
mletne!ufa1Wh1n.IDahssdd'aIr1DCWDxpsCasWrHmadfietffyGepeslSadtidme�l(14jdfihtlttDuSMus f—if-P-dTsid-151ldwafatslwAMMWhtirsd1,TniLLr<•sa,T-Imphp—i1-11.drdnu,nlm =80083
7dlirts HrthA th InnDrdp fyhw b FDImdnlGyOrslp�yahnsggee lion dtylo9fht. Nnih@Nhn; us uddnt Hint. 4451 St. Lucie Blvd.
Fort Pierce, FL 34946
(apyrigh1a1g16A�19Do1L�ssec-Ar�o�LTDo6DiII,P.E. Repredunianolthisdonment,inany krm,Ispro6i6itxdKBhoalt6enfienpetreissioehooA-I YDD1Tnsses•AethoorLTumhDIII, P.E.
Job
Truss
Truss Type
Oty
Ply
A0129150
69778
HA
Diagonal Hip Girder
2 -
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10.44:58 2017 Page 1
ID:IMTaSW VdxJ7_cF0OWg_MyeyiLhV-vOBDYW?F5Y0_wAJr2DcJAbHDxTo7B9E196r7gfySYMJ
e 3-7-12 i 7-6-7 t
3-7-12 3-10-12
2x4 II
48 II
3x4 =
1-3-10 -5-1 b 5-9-3
Plate Offsets (X Y)— [1:0-0-7 0-0-81 r1:0-1-4 1-8-51
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.28
Vert(LL) -0.02 4 >999 240
MT20 244/190
TCDL 16.0
Lumber DOL 1.25
BC 0.23
Vert(TL) -0.01 3-7 >999 240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.00
Horz(TL) -0.00 1 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
Matrix -MP
Weight: 41 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
puriins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation uide.
REACTIONS. (Ib/size)
3 =
307/Mechanical
1 =
549/0-11-5 (min. 0-1-8)
Max Horz
1 =
167(LC 4)
Max Uplift
3 =
-314(LC 4)
1 =
-482(LC 4)
Max Grav
3 =
307(LC 1)
1 =
549(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-266/331
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 314 lb uplift at
joint 3 and 482 lb uplift at joint 1.
6) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 39
lb down and 47 lb up at 4-2-8, 39 lb down and 47 lb
up at 4-2-8, and 88 lb down and 139 lb up at 7-0-7,
and 88 lb down and 139 lb up at 7-0-7 on top chord,
and 61 lb down and 104 lb up at 1-4-9, 61 lb down
and 104 Its up at 1-4-9, 49 lb up at 4-2-8, 49 lb up at
4-2-8, and 24 lb down at 7-0-7, and 24 lb down at
7-0-7 on bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-72, 3-4=-20
Concentrated Loads (lb)
Vert: 6=121(F=61, B=-61) 9=100(F=50, B=-50)
10=66(F=33, B=33) 11=-21(17=10, B=l0)
Beth!-Bns, et�guta>4. ne�e�no�'.r.71ASSE5(SAlri'j,6It3111!L4ftr9fN11GlS(JftUY(rOrcY'JiI{Wbi(Pe-YEYI'6m rerLrleilpp;r.!tututrcJ e@ru�dt frnsenipMiug{II�uNrtetmvrCrNa©;rElea-n3 SSett6etare �u. GhudmieNeln6�RC,tdr
Mdet�trWes:IdfknNfeSsiIX;hleN:i lttTntt0�4 brm'y6�.trfTts4'•dQ:sxlnmpIDorgmNsotvryatAmsrt:sfuil etytxeugemtSAry6r3t dts�dhsfighrmssgsdueemoNr,nloinr. lxit:tpw.opaet; Itri¢iutL^iets.sahtaDt Anthony T. Tombo III, P.E.
' e:rnedhtTnttrumrreiEhl69e eeyui klaldh U.xr, escnetto�md epsun:ta><j o,. ,uHe whdd5v�&IaWfaIN'uilielo63rze1r4L 1teen—lefit lCO¢te O.-M a ddtlmsk etfg1tslGyetnge6neee*ai F.nag sit iehrt!1aA4iryd i80083
lit k7tg O:sipratf tr. Ihetles ts!Nu®eleC olhrrtEim ne rridmsAtllruby4.^peslSieh�r��P�lp elrl�nlSGAntekusltxrx�dptlst.lPFl le:mrt8reesrnshTdes orGtimedMluftO.rspe,Lam h!Gt6 ecrsilnttYmh3ru,Ntts 4451 it. Lude Blvd.
thmtss&Falb.rtee�tpettptm.roggartress itNt:i lit Im Ptnp bltru is 1171sx stung o,npe,nTinsyma E.P. atglA4 tuatatnd!eftmst rt erulrN. Fort Pierce, FL 34946
(opyright®2A16A-1loclLrsses-AmhoayUeda III, P.E. Reptoduttionelthisdotument,inoayform,ispsohithedxGhouttbetnitlenptrmistioahomA4RoofTrosses-Aidonyl.TamboIII, P.E.
Job
Truss
Truss Type
City
Ply
69778
HJ2
Diagonal Hip Girder
1
1
A0129151
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:44:69 2017 Page 1
ID:IMTa5WVdxJ7 cFOOWg_MyeyiLhV-OaibmFOtssWrXKu1bw7Yipgiqt28wbcvOmagC5ySYMl
4-6-3 9-2-4
4-6-3 4-8-1
2x4 II
3
3x4
2-8-9-2 �l
2-8-9 -510
9-2-4
6-0-1
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL
20.0
Plate Grip DOL
1.25
TC 0.66
Vert(LL)
0.03
4-5
. >999
360
MT20 244/190
TCDL
16.0
Lumber DOL
1.25
BC 0.63
Vert(TL)
0.10
4-5
>708
240
BCLL
0.0
Rep Stress Incr
NO
WB 0.06
Horz(TL)
-0.00
4
n/a
n/a
BCDL
10.0
Code FBC2014/TP12007
Matrix -MS
Wind(LL) -0.04
4-5
>999
240
Weight: 53 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2 *Except*
W2: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 6-M oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
4 =
6/Mechanical
5 =
279/0-11-5 (min.0-1-8)
Max Horz
5 =
285(LC 26)
Max Uplift
4 =
-370(LC 4)
5 =
-798(LC 8)
Max Grav
4 =
219(LC 35)
5 =
727(LC 35)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-9=-275/136
BOTCHORD
1 -11 =-46/299, 5-11=46/299
WEBS
2-5=-489/442
NOTES-
1)Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; End., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; porch left exposed; Lumber DOL=1.60 plate
grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 370 lb uplift at
joint 4 and 798 lb uplift at joint 5.
6) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 152
lb down and 264 lb up at 4-2-8, 152 lb down and 264
lb up at 4-2-8, and 184 lb down and 102 lb up at
7-0-7, and 184 lb down and 102 lb up at 7-0-7 on top
chord, and 61 lb down and 74 lb up at 1-4-9, 61 lb
down and 74 lb up at 1-4-9, 155 lb down and 272 lb
up at 4-2-8, 155 lb down and 272 lb up at 4-2-8, and
106 lb up at 7-0-7, and 106 lb up at 7-0-7 on bottom
chord. The design/selection of such connection
device(s) is the responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-72, 4-6=-20
Concentrated Loads (lb)
Vert: 9=275(F=138, B=138) 11 =1 21 (F=-61, B=-61)
12=331 (F=1 66, B=166) 13=61(F=31, B=31)
e¢mr.x,nmafura�e.n, kno Tmsa(refa}sTeau rnxs s faaomcm fosfwy-rofayumetauarwn T¢rrmm�, a¢,nf ¢rf aar ae f¢nh�Qo¢.¢rPoq�f mfm.rt fnr, m u.f, s+�ard.r w wnr ex¢.med f ew m.¢rf
wvt¢�¢:skakenfh eOgnkeo4ls.T¢sonvh¢(wa�rrsv:m:�nepTmynm®eearPmd¢d¢rawn3rnfwmhdpdr:¢perm:fern&IDU¢If,nf¢TRI.Iffihyrnnarm4rtai¢dtn n¢7dnr
' nlaedl>sTunlrg4W2rghfie¢srysv.[didd0axr,EsOaxrres¢o-dr¢n�rarapo�u�a,uae¢addn:uCergfafrab�a, nteafmtne ddhrlCOaf e•�frudarTmr:¢mf hnrhanYT.Tombo III, P.E.
80083
ifv3 qpn ne . yfneT�.snefe,6slsdsaftv¢rsldlhhn�nsipTiryd : � 8n063
6srs3foig:sigerelhmmin. fgahs: wbralarufael¢GmnlgrldmdtaWtfejh sllceryld¢sdcm(1t9)pi lhmvfAecrrdeunl6rrnrdpilue.151M Nwjns Ti¢ofheesili:Lns0.•i,�s,T¢nL9ph snrailnnYmfi9ru,¢�ns 4451 St. Lucie Blvd.
mam,h6x11rtfNbryadryndnerfgdryleshrdnllNfnnd9n[yoaHt7lMbll�Msip¢,aLnsSpgshriaetoJedltrydOaTod¢efMa:mnddnd¢RFI. Fort Pierce, FL 34946
(apyrighf�tU16A-IroolTnsses-Aa16o�LTamhoIll,P.F. gepfodouiaoatthifdommem,ino ifform,isprohNedwhboulthwittenpermissic¢fronA-1Ruthann -Waorl.iambnIII, p.I.
Job
Truss
Truss Type
Qty
Ply
A0129152
69778
HJ2A
Diagonal Hip Girder
1
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@al truss.com
Run: 8.120 s Aug 16 2017 Print: 8.120 s
ID:IMTa5WVdxJ7 cF0O1
16 2017 MiTek Industries, Inc. Tue Oct 17 10:45:00 2017 Page 1
nyeyiLhV-snG_zbl Vd9eigUTD9denFONSSHNlf1 h2dQKDIXySYMH
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.75
Vert(LL)
-0.10
4-5
>815
240
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.67
Vert(TL)
0.15
4-5
>544
240
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.07
Horz(TL)
-0.15
3
n/a
n/a
BCDL 10.0
Code FBC2014rrP12007
Matrix -MS
Weight: 51 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
121/Mechanical
4 =
-52/Mechanical
5 =
283/0-11-5 (min. 0-1-8)
Max Horz
5 =
308(LC 8)
Max Uplift
3 =
-256(LC 8)
4 =
-95(LC 19)
5 =
-779(LC 8)
Max Grav
3 =
196(LC 35)
4 =
131(LC 24)
5 =
776(LC 35)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-313/120, 2-9=-287/84
BOTCHORD
1-11=-0/308, 5-11=-0/308
WEBS
2-5=-535/524
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf,- BCDL=5.Opsf; h=30ft;
Cat. ll; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed fora 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 256 lb uplift at
joint 3, 95 lb uplift at joint 4 and 779 lb uplift at joint 5.
6) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 152
lb down and 264 lb up at 4-2-8, 152 lb down and 264
lb up at 4-2-8, and 189 lb down and 102 lb up at
7-0-7, and 189 lb down and 102 lb up at 7-0-7 on top
chord, and 61 lb down and 74 lb up at 1-4-9, 61 lb
down and 74 lb up at 1-4-8, 91 lb down and 272 lb up
at 4-2-8, 91 lb down and 272 lb up at 4-2-8, and 39 lb
down and 55 lb up at 7-0-7, and 39 lb down and 55 lb
up at 7-0-7 on bottom chord. The design/selection of
such connection device(s) is the responsibility of
others.
7) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=72, 4-6=-20
Concentrated Loads (lb)
Vert: 9=275(F=138, B=138) 11 =-1 21 (F=-61, B=-61)
12=331(F=166, B=166) 13=61(F=31, B=31)
tYadtr-Hnu @¢¢ylIrma.Cu9d IO:F iIOSSE3(fNe)eE[31[t7llftt@INIIGIS(IIfiOY'WT3"il(1[9e71MYEMkn rrtd[[uip [mr!inc Mtxt ttuEni¢¢ksipOrs+i[ON}dNk➢w[l.[rtkt lt,rEkkntS'wfldue w. Cehve2min nlelnRelf4ul[
Whtm�arddts siedktsetitt@ttplLletdL lse[ms0ece[yretr7n,S,eds6rFrli>;±p@:7sln¢Ttbirgr¢akatetprnd@t{ed¢il¢il eyv:nagra{�lda{M@tl¢ipdfle mptTmeteleLM¢deTepuy,¢lotai. Tkdtdpecautt¢srafarut/ducsrmlddj Anthony T. Tombo III, P.E.
WerdhsTmskrmrtetisde mrnslirydC+eOmr,EeOneisadaueltpil¢de k7�C:npe,h@e teAedddt�@tiS(¢tl6lul'rFlriyc.§¢fml. tke ep:ml dlitl00¢t et Fii.¢fflt6.ss, tdtCiqkseTq,slaep,hslt,sIstnitmy t4iEle4rt¢siNerd #80083
@t6a1�{kdperad6aed¢.19ut'sededb�l0osdbjmdisulpMr¢n@e[taa{o�pwSA4V rn.pulphkn[tr, M,lde¢�Mpdpitar,Tnitf¢@t¢qn¢bbn.1m¢alktt¢;onv-,T-c6pho—i[¢nrm@�a,¢m 4451 St. Lude Blvd.
tdmntldmelye(Wedtpade{n@ncea, iydlremts@nhei Tk T.. hop Elm is HIM 1,814ptst[w,¢Tmsdpuz[.Iwo deq k014 M.1wa lecs¢tn ddlaftml- Fort Pierce, FL 34946
(apyright®7d16A-IRaolrnsses-Aethooyl.lomhoill,P.L Repeedodiaaait6isdommem:iaeayiosm,isptobi heiOhmrhowineapemissioolromA4boifrosses-Amhoayttomholil,p.i.
Job
Truss
Truss Type
Qty
Ply
69778
HJ2B
Diagonal Hip Girder
1
1
A0129153
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:45:01 2017 Page 1
ID:IMTaSW VdxJ7_cF0OWg_MyeyiLhV-KzgMBx27OTmZnel QjL90nEvdyhizOV7Cs43nH_rSYMG
4-10-1 9-10-1
4-10-1 4-11-15
n
N tz-
O4
V
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.75
Vert(LL)
0.05
4-5
>999
360
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.67
Vert(TL)
0.14
4-5
>553
240
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.06
Horz(TL)
-0.15
3
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
Matrix -MS
Wind(LL)
-0.06
4-5
>999
240
Weight: 51 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (Ib/size)
3 =
122/Mechanical
4 =
-57/0-5-5 (min. 0-1-8)
5 =
285/0-11-5 (min. 0-1-8)
Max Horz
5 =
308(LC 8)
Max Uplift
3 =
-263(LC 8)
4 =
-179(LC 5)
5 =
-824(LC 8)
Max Grav
3 =
189(LC 35)
4 =
72(LC 31)
5 =
755(LC 35)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-303/119, 2-9=-288/84
BOT CHORD
1-11=-0/308, 5-11=-0/308
WEBS
2-5=-567/492
NOTES-
1) Wind: ASCE 7-10; VuIt=170mph (3-second gust)
Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf, h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; porch left exposed; Lumber DOL=1.60 plate
grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 263 lb uplift at
joint 3, 179 lb uplift at joint 4 and 824 lb uplift at joint 5.
6) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 152
lb down and 264 lb up at 4-2-8, 152 lb down and 264
lb up at 4-2-8, and 184 lb down and 102 lb up at
7-0-7, and 184 lb down and 102 lb up at 7-0-7 on top
chord, and 61 lb down and 74 lb up at 1-4-9, 61 lb
down and 74 lb up at 1-4-9, 155 lb down and 272 lb
up at 4-2-8, 155 lb down and 272 lb up at 4-2-8, and
106 lb up at 7-0-7, and 106 lb up at 7-0-7 on bottom
chord. The design/selection of such connection
device(s) is the responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Unifonn Loads (plf)
Vert: 1-3=-72, 4-0=-20
Concentrated Loads (lb)
Vert: 9=275(F=138, B=138) 11=-121(F=61, B=-61)
12=331 (F=1 66, B=166) 13=61(17=31, 8=31)
tr ,nr-n�nangorndt. ee �naar noss¢{sn tr r[rau i rut a m,mness rusmu ruta)t erosvue mr a rMryeni�N, d ,nercdte, nea, Tan a,ig,rmr�(t� mlm reaii. rnu m,u.r �., r�cdnt w ad,n dia. n r�lm et tcomlf
fUT,kt�t4rrldessiAku,rbrStlrOplesd4sstTms0eva6g�e(ie,lrealTGg�t.eesdnrpl�7rgrtumneeRraudCrrak:su,dnrunru3mra�e+i.aibr@x4uvd9eugYim,eycWnAe@UWi,n[nrrn.lkhdpnaolentletui¢doucumswi AnthonyT. Tombo III, P.E.
nersedtna,un,mduslhallnrii'U. ddo��,aonefrresmdoy�nnrar�gemri,oe«dmdrxu'aracwrar>2tsu�gdmma.mtmnddamnne�eu.�d�rims:cdrcgtirqdatgamdae.nrrmrssmheemrn,�aatd BOD63
muugoes cd6tnly.seMus rd'nrcT60nd�rnCrcesulryldundsild singrcnllfnlduadea(tlsQt1641hmnlStCltntdaenetxFesdrusaa17F1idmWusneeTSnWhend�Lns�ge,TmsR:pfy�enolTnss4m4mu,Nm 4451 St. Lucie Blvd.
mmnslernearyttwmgeagna.m,gdreonh,sh,tlgrnnDsnaOghs�uc,rah:uWwdsx,,,runssrmshlwndsrplriuur.magadcramcsmnadmretns. Fort Pierce, FL 34946
(opyrigbi02016AdRoofinsser-Anthony1.Tombelll,U Reproduction of ibis domment. in any (am, is pioblited without the viftlen permission from A-1 Roof frissas - Anthony I. Insole 111, F.L
Job
Truss
Truss Type
Qty
Ply
A0129154
69778
HJ2C
Diagonal Hip Girder
1
1
Job Reference (optional)
Al scoot I russes, t-on Pierce, t-L 34946, oesign(aoaltruss.com
Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:45:01 2017 Page 1
ID:IMTa5V VdxJ7cF0OWg_MyeyiLhV-KzgMBx27OTmZnelQjL90nEvemhitOV3Cs43nH_ySYMG
44-12 8-_11-7
T
0
2-8-9
2-8-9
�-2 4
5-1
8-11-7
5-9-3
--
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
I/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC
0.69
Vert(LL) -0.07
4-5
>999
240
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC
0.68
Vert(TL) 0.11
4-5
>598
240
BCLL 0.0
Rep Stress Incr
NO
WB
0.06
Horz(TL) -0.14
3
n/a
n/a
BCDL 10.0
Code FBC20141TP12007
Matrix -MP
Weight: 46 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
78/Mechanical
4 =
-86/Mechanical
5 =
27910-11-5 (min. 0-1-8)
Max Horz
5 =
280(LC 8)
Max Uplift
3 =
-225(LC 8)
4 =
-136(LC 19)
5 =
-754(LC 8)
Max Grav
3 =
194(LC 32)
4 =
131(LC 24)
5 =
736(LC 35)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-275/110, 2-9=-255/90
BOT CHORD
1-11=-0/280, 5-11=-0/280
WEBS
2-5=-480/464
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf, BCDL=S.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 225 lb uplift at
joint 3, 136 lb uplift at joint 4 and 754 lb uplift at joint 5.
6) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 152
lb down and 264 lb up at 4-2-8, 152 lb down and 264
lb up at 4-2-8, and 189 lb down and 102 lb up at
7-0-7, and 189 lb down and 102 lb up at 7-0-7 on top
chord, and 61 lb down and 74 lb up at 1-4-9, 61 lb
down and 74 lb up at 1-4-9, 91 lb down and 272 lb up
at 4-2-8, 91 lb down and 272 lb up at 4-2-8, and 39 lb
down and 55 lb up at 7-0-7, and 39 lb down and 55 lb
up at 7-0-7 on bottom chord. The design/selection of
such connection device(s) is the responsibility of
others.
7) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-72, 4-6=-20
Concentrated Loads (lb)
Vert: 9=275(F=138, B=13B) 11=-121(F=-61, B=-61)
12=331(F=166, B=166) 13=61(F=31, B=31)
r ,;,t-Fleni@u�urrenn ne •u r@r,: rtu5ers(Srdtrrsi�u taus a raeomcssrostaurw�urnautsuur taa rrntt<,�np,:.nn s<trKlmr urr t�,s r�r�taa�.mrpoe;am rm.rt roars le,tt.tdaeea saertda� n+ lsr� ce.�re nns m m� tao.alr
MT. kamehrom"WokiaihrNTaagk Sdt MI MS Csr_s lltmaoo.LSpo<4/F< @: Sad a.1TP gRstds.-P.,d@errde:uudusb:xurrxr ad4tr@x imp d9,oft Tm-; egmd n@:Too It, W.Titi- heftonnsrtees, lair da.s sowul. Anthony T. Tornbo III, P.E.
' Wnedr,;Ims iarsgh&Sh@emrydilai d6, a.iw,aa80083
m ratwimdpunuiioauw. meder,dmirs�To¢mesa�aa:lr,.Ed.ndarrrz�ka�w5dd51d�roda�putr.kesxenrTnmsw�,rd�txiysdreAae. IFFl (rims@eregnukTEss udk6rSd2luss@fps,Tnnoedp t,enQeTmsttmnsne,,aen 4451 St. Lucie Blvd.
t@nrlsi Edmdkrarwaaaepedgnm Haug IrdlFas whit ik Tma Dian lip,, @ rll@esc@iq win"TmsSphf himsa d.11,11iy tnaidi@e! Ma: in it EdhitsliFl.
� Fort Pierce, FL 34946
(apydgbt®tRldklRoofTnsses-ArlboayLTonbo111,P.E. Repraduoionoftbiskumeat,inany laim,ispioRitedwuhouttbewiineaptrmiisiaofrom A-IRociTtasses-AmboayMombe111,P.F.
Job
Truss
Truss Type
Qty
Ply
69778
HJ2P
Diagonal Hip Girder
1
1
A0129155
Job Reference (optional)
Al moor Trusses, tort Pierce, t-L MV48, aesign(maltruss.com Faun: 8.120 s Aug 15 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:45:02 2017 Page 1
ID:IMTaSW VdxJ7_cF0OWg_MyeyiLhV-o9OkOH219nuQOoccH2gFKRSoa52D7yGL4kpKpQySYMF
4-10-1 9-10-1
4-10-1 ' 4-11-15
LOADING(psf)
SPACING-
2-M
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.75
Vert(LL)
0.05
4-5
>999
360
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.67
Vert(TL)
0.15
4-5
>544
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.06
Horz(TL)
-0.15
3
n/a
n/a
BCDL 10.0
Code FBC20141TP12007
Matrix -MS
Wind(LL)
-0.06
4-5
>999
240
Weight: 51 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation uide.
REACTIONS. (lb/size)
3 =
121/Mechanical
4 =
-52/Mechanicel
5 =
28310-11-5 (min. 0-1-8)
Max Horz
5 =
308(LC 8)
Max Uplift
3 =
-263(LC 8)
4 =
-180(LC 5)
5 =
-827(LC 4)
Max Grav
3 =
189(LC 35)
4 =
73(LC31)
5 =
756(LC 35)
FORCES. (lb)
Max. CompdMax. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-301/120, 2-9=-288/84
BOT CHORD
1-11=-0/308, 5-11=-0/308
WEBS
2-5=-568/487
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=S.Opsf; BCDL=S.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; porch left exposed; Lumber DOL=1.60 plate
grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-" tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 263 lb uplift at
joint 3, 180 lb uplift at joint 4 and 827 lb uplift at joint 5.
6) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 152
lb down and 264 Its up at 4-2-8, 152 lb down and 264
lb up at 4-2-8, and 184 lb down and 102 lb up at
7-0-7, and 184 lb down and 102 lb up at 7-0-7 on top
chord, and 61 lb down and 74 lb up at 1-4-9, 61 lb
down and 74 lb up at 1-4-9, 155 lb down and 272 lb
up at 4-2-8, 155 lb down and 272 lb up at 4-2-8, and
106 lb up at 7-0-7, and 106 lb up at 7-0-7 on bottom
chord. The design/selection of such connection
device(s) is the responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=72, 4-6=-20
Concentrated Loads (lb)
Vert: 9=275(F=138, B=138) 11=-121(F=-61, B=-61)
12=331(F=166, B=166) 13=61(F=31, B=31)
Yrakf-flea armll¢redn Sk'J•I IODi i1mSES(S'.ilflj.Li[3ll I�LIS6f01DIM4fRNYj {arcr')1(IrD61106YEYt'Wn rrtdt h,iprcrcEnrMrnl rlefnld,lrtnCe!IpDrtebl�IDD`,dDrkCarLlarlr W,rf.IrM iSkatderw, Cxlnrdmin dddn�tGD,,dt .
WLkae.dups,kokudih201041t,dtAsrim!D-v,e6pexlte,tp:nhstrye:srdnmgrt+�rgnamere4�aaratnk:sluduga:aasm d�try�rnehsgd�em/errnct!res4o!eemDedr,ntomtnehupasaeµn!,I�aradoas.mwuar:, AnthonyT.Tombo111,P.E.
Zt
of nedMTirss hr�taEtr;IsBrnymti:laldh0.sc,�0n,7crQrmdgran deW610!vpa,6@e adedd8!�&IGnih4alen7GgaN nfm-L lkgtmdd6rlDDNerfeNnedBrim,, 4drWkrslq,skge.ash"diwnlfrasrsHlM@enrymirBiryd
mGDtgD!si¢acd [„r~rrd,a. Nedra se lab YalDDrdb f3di—Ari!Ihndtkw4ikrnai SeflyhhMfiM(11!9Jdrdk l?M.I l(A er,dcr Mr-dpilse. lFFl id�ns&ngns*uTFie, ®dAN!dMlms0:4 n,rm,s an ? 80083
g iptgsardtmsimhdnu,rdm 4451St. Lucie Blvd.
rl5oais:hfadkrLWN rpaiq,rk smem Irtl Ixmsh!d„L Ik tnstaedp ha0.r! h rglMk]IigD,dpa; whnsSldm hlk!a drry Mafiq. SDafadedffirs orrsddfulkTtL1.
(apyiighf 02016A•Itoafbasses-AathonyT.TambaIII, P.L tepraludianafthislommeet,inanylom,isprohih0elwithoutthesnitsenpemissiaaisonsA-IAoolirossas-AmhonyT.TawbaIII,P.L Fort Pierce, FL 34946
Job
Truss
Truss Type
Oty
Ply
69778
HJ3
Diagonal Hip Girder
2
1
A0129156
Jab Reference (optional)
All Roof Trusses, Fort Pierce, FL 34946, design(caltruss.com
Run: 8.120 s Aug 16 2017 Print: B.120 s Aug 16 2017 MiTeK
ID:IMTa5WVdxJ7 cFOOWa MveviLhV-GMv6cd
Inc. Tue Oct 17 10:45:03 2017
2x4 II
2 8-9 3-2-4,
7-0-2
2-8-9 -5-1
3-9-14
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL
20.0
Plate Grip DOL
1.25
TC 0.56
Vert(LL)
0.02
4-5
>999
360
MT20 244/190
TCDL
16.0
Lumber DOL
1.25
BC 0.60
Vert(TL)
0.05
4-5
>952
240
BCLL
0.0
Rep Stress Incr
NO
WB 0.05
Horz(TL)
-0.10
3
n/a
n/a
BCDL
10.0
Code FBC2014/TP12007
Matrix -MP
Wind(LL)
-0.02
4-5
>999
240
Weight: 37 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
3 =
-36/Mechanical
4 =
-134/Mechanical
5 =
33810-11-5 (min.0-1-8)
Max Horz
5 =
219(LC 8)
Max Uplift
3 =
-112(LC 8)
4 =
-174(LC 19)
5 =
-685(LC 8)
Max Grav
3 =
37(LC 32)
4 =
48(LC 26)
5 =
636(LC 35)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
WEBS
2-5=-348/357
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; porch left exposed; Lumber DOL=1.60 plate
grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 112 lb uplift at
joint 3, 174 lb uplift at joint 4 and 685 lb uplift at joint 5.
6) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 151
lb down and 258 lb up at 4-2-8, and 151 lb down and
258 lb up at 4-2-8 on top chord, and 61 lb down and
74 lb up at 1-4-9, 61 lb down and 74 lb up at 1-4-9,
and 152 lb down and 266 lb up at 4-2-8, and 152 lb
down and 266 lb up at 4-2-8 on bottom chord. The
design/selection of such connection device(s) is the
responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-72, 4-6=-20
Concentrated Loads (lb)
Vert: 9=269(F=134, B=134)10=-121(F=-61, B=-61)
11=324(F=162,B=162)
w,ny-n� em�lryRr�.et luossnmsaN1131MUMS eemmnaulmTor-rorrlmeamimsuurma reLtli.Ip 7-*,,!e„a.t,As,Tn„knpD.,.Ipe;.la,lm.rr.r�km,FLI& ,skdtdv,m u,uvee. <mdmv,rca,us
16Tttnemerp'm„YAk,ulfurkiWhk,di 4,TrusOsg 6seee[,2,5r�1'Trued=tote®P�'�t4+ot��patdlitr,w4uiudnrh:,dq,nrxdr tr6r7a/ny®dexsgh rm; ttImar Tooulr,l. MI. I. mWoy Anthony T. Tombo Ill, P.E.
Zt-
W.0 MT,m fa.1b&r IsN,.1 :Lhddga,gfe ati.,n',t�@,mei,leann,k7(pOa.�a,hle amddfi3OC@tR(a11k6xIk;IfaruHafiM. ikserynddfu100netpfi:nmdhtir<,,,I.dKnrk+ele3,dctl,,erfefdsalkn�>1eGYtBen,rns�iryid #80083
nenatnorslys d6tm1rt.11emsMtd'ukTOCne�lrzCasnli,itfnesdhe4fr4ceaSdhldnsekeQ4llfik/lrlFlulSinmedarilhrdpts,.1r41ldnnB�ngnu3bnadAt,iPnkn;rdvp,Tm osy,teF,t neTns:umnmu,Nm 4451St.LudeBlvd.
tem,n,mm,fh,c,:omtpedernarvr�ydrmonmte,tlkra;seedybJuIsINfitkgltgDn1jtt,uumsTax[spadisIV11q.soasoeQdba:misadrnluTru. Fort Pierce, FL 34946
(opyrigbta2UI61FiioofTivsses•AefbooyLlambotn,P.F. Rep,oduniaoaffhisbrumeof,inonyfotm,isprobi6hedwhhoufthewrineafeneissiamfrom64loafhasses•AmbomyT.tomboIII,P.F.
Job
Truss
Truss Type
Ply
69778
J4
Jack -Closed
Sty
5
1
A0129157
Job Reference o tional
Al Roof Trusses, Fort Pierce, 1 34946, design@altruss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 METek Industries, Inc. Tue Oct 17 10:45:04 2017 Page 1
ID:IMTa5WVdxJ7_cF0OWg_MyeyiLhV-kYVUpz40gO87e5m70Tj PsXlQutBbsjeY2lRulySYMD
3-10.8
3-10-8
2x4 11
3x8 I I
date uttsets (X,Y)—
11:U-3 f5,0 0-121, 11:0-1-7,1-2-13]
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/dell
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.09
Vert(LL)
-0.00
4
>999
360
MT20 2441190
TCDL 16.0
Lumber DOL 1.25
BC 0.12
Vert(TL)
-0.00
4
>999
240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(TL)
-0.00
1
n/a
n/a
BCDL 10.0
Code FBC2014/rP12007
Matrix -MP
Wind(LL)
-0.00
4
>999
240
Weight: 22 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-10-8 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
3 =
76/Mechanical
1 =
267/0-8-0 (min.0-1-8)
Max Horz
1 =
119(LC 12)
Max Uplift
3 =
-90(LC 12)
1 =
-120(LC 12)
Max Grav
3 =
76(LC 1)
1 =
267(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1)Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 90 lb uplift at
joint 3 and 120 lb uplift at joint 1.
LOAD CASE(S)
Standard
Ymitr-Flnntlmtlk¢nrfnrw'!dIO;F llaSfESFinlrl•J.6It311 WarOMORm4rivosras tunas mirhm rrdt&ilp rmc!IntudrtdMa,udtlnnhegsWcxglNC;dmimnith:hio,rErrmmssmta.:re. Tdeure�inraemmesgamr
wvtm�ffi rWssSgkmsq meipins,tdta,ermsownh�nnpr sr hpnc;o:,mnairo7 ymm m.m�na,dapr,unense,mrr pcnarm mi, pamemp,imsryimn�soonir,araTar is kupmunren> doruLLnn msum AnthonyT. Tombo I11, P.E.
' Nn:tsw:shmlzuTln7tsn9t,npn9:W1d�O.ur,�Omi,eflnu<igeCnAt Wig gmQ.e,h9eurteddliWdG@en[QIISeImISslGgdiuliFFl.rkeenimldfnrOOulssrnldnedflrTms,IsCedagFeu7gileep,nsW.tl�nlhe�s4dhren.rmOa J 460083
4451 e: rr7tarO:siguvl hahcta. Igatnm rd u &IaC N3eptEi,nnlpi�dnesditek;iai (rep:sl Sch¢Ideme,t[SI)psF.hllrrFlrtf SILO m,dnuul6rpadpilue. lTFI winsOensstmV'mn alQntssllkLm @spe,Tnss a::iphT:,mdlnss4mh3nu, ttkss
tam,wmrytrwnmWctgmm�spymr>anm�dsarnssonprcpHnr,tmrngoapn,aunspmopcarimnafgmaresmtasmna�uasma. Fort
Lurie Blvd.
(opyrighi D Edld kl ioalTnsses •Amhony T.Iomha W,P.E Neptodunioa althisdamment. in anyform, is prohi6hed wdoutths written /eruissiaeNon A -I toof Trusses. Aethanyl. Tambo lll, p.E. Fort Pierce, FL 34946
Job
Truss
Truss Type
city
Ply
A0129158
69778
J5A
Jack -Open
4
1
Job Reference o tional
Al Roof Trusses, Fort Pierce, FL 34946, cesign(cgaltruss.com
Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:45:05 2017 Page 1
ID:IMTa5W VdxJ7_cFOOWg_MyeyiLhV-Ck3tOJ5eRiG_FFLByBEyy44StICwKJ4nmi1_QlySYMC
5-0-0
5-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.17
TCDL
16.0
Lumber DOL
1.25
BC 0.16
BCLL
0.0
Rep Stress Incr
YES
WB 0.06
BCDL
10.0
Code FBC2014/TPI2007
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
3 =
63/Mechanical
4 =
-39/Mechanical
5 =
431/0-8-0 (min.0-1-8)
Max Horz
5 =
220(LC 12)
Max Uplift
3 =
A08(LC 12)
4 =
-93(LC 9)
5 =
-143(LC 8)
Max Grav
3 =
98(LC 19)
5 =
431(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=326/266
BOT CHORD
1-5=-273/349
WEBS
2-5=-437/450
NOTES-
1)Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed; porch left
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
DEFL. in (loc) I/deft Ud
Vert(LL) -0.00 4-5 >999 240
Vert(TL) 0.00 4-5 >999 240
Horz(TL) -0.03 3 n/a n/a
3) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 108 lb uplift at
joint 3, 93 lb uplift at joint 4 and 143 lb uplift at joint 5.
LOAD CASE(S)
Standard
PLATES GRIP
MT20 244/190
Weight: 23 Ib FT = 20%
v�r•nmum�gurnnru'4uagrnussEs(sru[riacaunwssumumasstaraa("1a[ontucINVt— rsrnm .ivasdmeeno.wr
tLrrtw. wlletfss5dlk-ellultipiwlt Idl
' wmdNlrmshr hc� istkem nfrx dtolUne,f�6milr�-'r+t! tib o... Mthonylz. Tomb- [II, P.E.
mi r r W m�- x�-�,kae-mddtuor,etittmtahmia�ir-r-l+-Im1 myr-ddts,mnalerrrasrsedntmn:r<e��g�rq.,�.egl.�srfrn�.wka,rst>f,naen�nsuJnrd _ 80083
mun�o-sim wrl>cn.latdlssdtdotsroo�sae�e�fdr,:tdamdmtsary6r�atuquuzdmpwrwvnrrnosswrerdanvm�sd .mtt caeny� aannranm��nns�v�s,rnuoripfgnaulrnnYmh�na;nm 4451St. LudeBlvd.
ldmn-hftdkr.-nmryelynxnuc1y.11Inn on6ettern,osogsaron,hlarmrogmatey-nnsslmshlmeV-1101ug.Fort Pierce, FL 34946
(epydghi02016A•ItoolTnsses-AothooyHamboIII, P.E tepmdurti000fthisdommrm,inany form, hprobi6itedwithouttheminenpermissionfrom 6-IPooMisses-AntbuyT.TombnIII, P.r.
Job
Truss
Truss Type
City
Ply
69778
J6
Jack -Closed
4
1
A0129159
Job Reference o tional
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:48:58 2017 Page 1
ID:IMTaSWVdxJ7_cF0OWg_MyeyiLhV-uZeyw yoaHdxj3fz6cvbuCEF3Di1Qhe4LSzp5kySYIZ
5-4-8
5-4-8
2x4 II
3x8 11
3x4 =
Plate Offsets (X,Y)—
[1:0-0-2,0-0-91, [1:0-1-7,1-2-131
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.24
Vert(LL)
-0.02
4
>999
240
MT20 244/190
TCDL 16.0
Lumber DOL 1.25
BC 0.25
Vert(TL)
-0.01
3-7
>999
240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(TL)
-0.00
1
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
Matrix -MP
Weight: 30 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 54-8 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
3 =
158/Mechanical
1 =
323/0-8-0 (min. 0-1-8)
Max Horz
1 =
167(LC 12)
Max Uplift
3 =
-148(LC 12)
1 =
-147(LC 12)
Max Grav
3 =
158(LC 1)
1 =
323(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-185/339
NOTES-
1)Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf, BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Extedor(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) . This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 148 lb uplift at
joint 3 and 147 lb uplift at joint 1.
LOAD CASE(S)
Standard
t®out•nmuauvgllrrtrir.@e•ea lop[ nostafultsygnau ItltlsEmtmneessmi0tlj I EOUKWPirEWbi'6m ert@ttuippnidm¢{rtd¢h:¢tl:rnnEeslpE¢e flRtrd@eIsaryLE¢av 47,1ik%na tintdae nt ErL¢aler.W Mel®@e IMall
FLhtr�rmadmss4dfkv¢tlor@t1Wp1<adi lsvimsgng Fq¢ve[t,SisotryFspu�.@e!slnmrlWrtpe::dsmaev adevttdrsinil¢gan,ny:cpe:d�YVMEe 6sLpdhsujeTm:te a¢@eEEo¢ry,at¢TnS t�teupnaaFas.l�utase¢c sa�etcq, Anthony T. Tomlto 111, P.E.
ae¢edh:Tm:farrytumyfs@amim@:Igdd E.w,la0.adsnQamdgadn@eEE--.�a,tv@a,wvAd4s0G@eD!¢tla6¢i'mtlar¢h¢eiel4 lh e�mdot@rfEE¢lryfieil.ud@eTm:, hdacig4seTat, Yaen,osLhowWfr¢uggstilTle�r,�midiryd a 80083
@v lr7rorEvviper¢dtva raa. lEMes¢IM@li!TPCMExI::Cm¢1rii:Gaysd&Feddy G�enitdt¢IduaN¢1(�idkkeltlFi NSIUn:AeeeeedrixzdpMae.TEFl ldun@ertgns�l3n¢rkti¢dCeLn.aka,Trtulgsmtyse¢mT¢ssamsdnu,nt¢s- 44515t. Lucie Blvd.
a@enasekfudha(¢nNagedq¢u rimrshdiiumv @vahaL Ih tn¢hrop 6thm tl Elf � kJtur Evsyn,¢Lm1pu6{Y:a dvvylaJtug. t@atadcel@ra; ov ¢ d�adkTtl.
Copyright ®tpl @ A•I Aaof lnsses • AeshoayGTambo 0l,P.L tepsodonim OfAis document, in anyfmm, is pm6T0ed whhool the xtman permissiao from Ad 9oalTnsses-Ambooy LTambo III, p.L Fort Pierce, FL 34946
Job
Truss
Truss Type
Qty
Ply
A0129160
69778
J7
Jack -Closed
2
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:45:06 2017 Page 1
ID:IMTa5W VdxJ7_cF0OWg_MyeyiLhV-gxdFEf6GC?OrtPwN WulBUHdcriXV318x?MnYyBySYMB
6-6-8
6-6-8
2x4 II
3
2x4 II
2-0-0 �
2�0 0 N 0 0 4-2-8
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL. in (loc)
I/deft
Ud
PLATES GRIP
TCLL
20.0
Plate Grip DOL
1.25
TC
0.22
Vert(LL) 0.02 4-5
>999
240
MT20 2441190
TCDL
16.0
Lumber DOL
1.25
BC
0.20
Vert(TL) 0.02 4-5
>999
180
BCLL
0.0
Rep Stress Incr
YES
WB
0.07
Horz(TL) 0.00
n/a
n/a
BCDL
10.0
Code FBC2014/TPI2007
Matrix -MP
Weight: 41 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2 `Except'
W2: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
pudins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
4 =
125/Mechanical
5 =
463/0-8-0 (min.0-1-8)
Max Horz
5 =
285(LC 12)
Max Uplift
4 =
-212(LC 12)
5 =
-154(LC 8)
Max Grav
4 =
139(LC 19)
5 =
463(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-441/378, 3-4=-295/279
BOT CHORD
1-5=-349/442
WEBS
2-5=-584/541
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf, BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed; porch left
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 212 lb uplift at
joint 4 and 154 lb uplift at joint 5.
LOAD CASE(S)
Standard
wsaus-nnvemqulnre.tu9a sari nmsEs(sP1Q�,7[3ll smn a soAomCss[mtaYj w[ar)ttnaat[lbYfst' mn r�swip pae=stns nswrin um, mss h,��Un:q{@1;amesargr lr:G �o,u. sa�su rm!sam m.141sn Cw.�n rndn 6e srA.u�s
gmidmsffir�dn sidlkneef.meiDCwle sdA. rimTnn Dace btaxr{u,7rushlsNe><tae»inalfDorgrzaasmrvs3nt6esnk:sueaayrnigrnpcadhht celtapdsempetm:h n�teCnry.atn inL rahsq,muo etl�¢iwl�ins mn7adr. Anthony T. Tomtro EI(, P.E.
' aemdonLmfxmptsi�sis8s,nrusuffatdMD*mr,Q:6netseAsmdgednSsa7[.tD:siger,hdeumddMmGdr�dtwlmel5alfurutrneli4l. Re ennrtl dfiesCPdmrsels.nahrTms; mdstiq .smge,6:W<tineti hemysidlle�nssrt�isOfid A80083
pesr:lrgDesiperalhsmedrt. IDtdn sd rauo:lDC nlmzinOmnspsdossarelraEq (scrnsiSdnll�Sreeca;uPtiAG nlmuesw wd—Alnt-dgas:ot MI tdneswns<nu4ten ulGBad 9:LnsP:i,oe,T.. Wino I.O.ltnn Wm 4451 St. Luele Blvd.
$a-hskemlhe;.mmrpmdgnm:nmq h oprms hnh!L lh TrraDwst rocs, BF111, kliq oratm,mlrmsrdn toms. 1.rW 4 Auwm d Moos no ndfinlmMI. Fort Pierce, FL 34946
(opyright91016A-I PoolLosses•AnthooyT.immhmlll,P.E. Reprodudindthisdotumm,immnyfmrm,isprohlhitedwBhomtthewdnenpesmissionfrom A -I Pool Trusses•Aethomyl.lomholll,P.E.
Job
Truss
Truss Type
Qty
69778
J7A
Jack -Open
7
7Plyi
A0129161
Job Reference o tional
Al poor s cusses, rori rierce, rL a9avn, aessgnrdaiiruss.com
LOADING (psf) SPACING- 2-M
TCLL 20.0 Plate Grip DOL 1.25
TCDL 16.0 Lumber DOL 1.25
BCLL 0.0 Rep Stress Incr YES
BCDL 10.0 Code FBC2014/TPI2007
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
3 =
128/Mechanical
4 =
30/Mechanical
5 =
481/0-8-0 (min.0-1-8)
Max Horz
5 =
309(LC.12)
Max Uplift
3 =
-210(LC 12)
4 =
-26(LC 12)
5 =
-155(LC 12)
Max Grav
3 =
197(LC 19)
4 =
69(LC 10)
5 =
481(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-539/413
BOT CHORD
1-5=-377/476
WEBS
2-5=-628/714
NOTES-
1) Wind: ASCE 7-10; Vult-170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed fora 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:45:07 2017 Page 1
ID:IMTa5WVdxJ7 cF0OWg_MyeyiLhV-97BdR_6uz1WVZVa3bGQ1V91O6tgoC24EOW5UdySYMA
7-0-0
7-"
CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES GRIP
TC 0.30
Vert(LL)
0.02
4-5
>999
240
MT20 244/190
BC 0.19
Vert(TL)
-0.02
4-5
>999
180
WB 0.09
Horz(TL)
-0.04
3
n/a
n/a
Matrix -MP
Weight: 38 lb FT = 20%
3) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-&0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 210 lb uplift at
joint 3, 26 lb uplift at joint 4 and 155 lb uplift at joint 5.
LOAD CASE(S)
Standard
vuLr-rimuamrAwiNr •Id loaf TI Brumrtmsur:uuetosnmesscusmurimaryucwaisunramt r<apw,�msa�.e,masmssasp:ms.gpo dai,eat.t�rsm,u.rmm�,srvrda:re.aass,ee.isssddm�suo.:sry
wnt msrws::>mr:,ItaxiWau,ai6.rm:nmys[y r{utrGmru msmnasrmoarams,e:Mittr.otamtTu6sq,m tnitd. "`4w3r AnthonyT.TornboHI, P.E.
Zt-
480083
44515t.LucfeBlvd.
Fort Pierce, FL 34946
(apnig6t®tG16A-IiaolLisses-Aet6onyr.TomEolq,Pi Yep:odonionolthisdaomerf,inany form, irprohaaelrithoutiAamineoprrmisdoofrom AdAaolTrussec-Act4auyr.TumEoIII,P.E.
Job
Truss
Truss Type
Oty
Ply
69778
RP
Jack -Open
7
1
A0129162
Job Reference (optional)
„r Ruui r ru5ses, run rierce, rL sgavn, aesignLa-tuuss.com
Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10:45:08 2017 Page 1
ID:IMTaSW VdxJ7_cF0OWg_MyeyiLhV-0JI?fK7WkdeZ7j4mdJnfaiiwGVBjXfbETfGe14ySYM9
7-0-0
7-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.29
Vert(LL)
0.03
4-5
>999
240
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.28
Vert(TL)
0.03
4-5
>999
180
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.07
Horz(TL)
-0.04
3
n/a
n/a
BCDL 10.0
Code FBC2014frP12007
Matrix -MP
Weight: 38 lb Fr = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
128/Mechanical
4 =
30/Mechanical
5 =
481/0-8-0 (min. 0-1-8)
Max Horz
5 =
309(LC 12)
Max Uplift
3 =
-210(LC 12)
4 =
-123(LC 9)
5 =
-198(LC 9)
Max Grav
3 =
189(LC 19)
4 =
68(LC 3)
5 =
481(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-478/423
BOT CHORD
1-5=377/476
WEBS
2-5=-653/565
NOTES-
1)Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed; porch left
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 210 lb uplift at
joint 3, 123 lb uplift at joint 4 and 198 lb uplift at joint 5.
LOAD CASE(S)
Standard
v,hE-rrm,emgFquKree7aEOCF loi6 Fl0)6n3LF1Yf6fpo CAS(CTOY IIFEitIC9a1FCeYYI lmntrtetteilpfmc rutrtaledtnedtfnssEedptrnhEpCC)¢ilorlAsyl.fdaO,KI&-Siwidnru Cdrerelahesoleene,Too, uIf
ILTrhromtsdmstlAYemdtrm WWI, Is tdt Is tap., It Anthony T. Tombo 111, P.E.
'' u/rudnntrmstxmryd ssisedrt:ry:stfaid&Cmr,eaC.deiteQandge2nmGHgC:!.gn,heesmedtttiro(.mRFdtahalkitgaLd1E41.Ile gpvddSHOW ofUm 0,Sefi%.hdtfghtdogdagehddnwndhmgsldihhregmhCi,a =80083
lidbugo:d><uattundn. 4451 St. Lude Blvd.
ma.hdamslFY;arretpsseq�u.nzgydvlomshnNAlit TnsiD.0Bp.'Is1eFmtrygodsipynuusSphsDisenottsyV:1E.masadadaysssnuemddhml. Fort Pierce, FL 34946
(opyrighI021116A.11aeffresses-Adaoyf.TomEoI11,R.F. Reproduction ofthisdocomest,ioonyism, FsptobiQieedwhboutihewhienpermissiaefromA-1RaolTtasses AothooyT.lomholll,P.E.
Job
Truss
Truss Type
Qty
Ply
A0129163
69778
MG01
Jack -Closed Girder
1
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
4x6
2X4 II
Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10*45:08 2017 Page 1
I D:IMTa5W VdxJ7_cF0OWg_MyeyiLhV-0JI?fK7WkdeZ7j4mdJnfaiixOV34XgkETfGel4ySYM9
5-0-0
5-0-0
2x4 112
9X9 —
Dead Load Dell. = 1/16 in
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.24
Vert(LL)
0.07
3-4
>832
240
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.83
Vert(TL)
-0.13
3-4
>448
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.06
Horz(TL)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2014frP12007
Matrix -MP
Weight: 39 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 8-9-15 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
4 =
601/0-8-0 (min. 0-1-8)
3 =
778/Mechanical
Max Horz
4 =
211(LC 5)
Max Uplift
4 =
-228(LC 8)
3 =
-556(LC 8)
Max Grav
4 =
601(LC 1)
3 =
837(LC 29)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 228 lb uplift at
joint 4 and 556 lb uplift at joint 3.
6) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 473
lb down and 269 lb up at 1-11-4, and 473 lb down and
269 lb up at 3-11-4 on bottom chord. The
design/selection of such connection device(s) is the
responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (pin
Vert: 1-2=-72, 34=-20
Concentrated Loads (lb)
Vert: 5=473(F) 6=473(F)
9tnlep-rlmvn�rrenerne�uruarnossaruumysnsur!rxseelroinemtonau-tcta7urcanlsunrr� Taarmm��en,wnaresn,msr�nrnl;,osu�poo>a�a�ir�,m:rt.tmn.,f�nmm�n. wn:c.�.wranmrtrrzn.�tt
Iaveaaennrddrss�krsestaraatDOnlrtdr rsarmso:u�[y�a(u,srnuesrrnm,a:sstn�rm rgmmsnreeransrrshsshd egh�roprdpnrtnryranesmxdrsh�e rms apasdnneToonlr,rd�mi nednaapans.�wn,sens, ss,>vrwr
Zt
mn na Tmstr�nn�shmragnngdman .taa.ur,eaadggwannewton,haenneaansanrarmsat7lr�irwo�astnt. nesnmadrwraaat.���.nrmtms,tarr�bdr� smgr.�hem.nnmgsals.0 ntnswnr T : Anthony T.A Tomb80083 III, P.E.
fiadDIDaiw.ibnaan. raannsemh mtoo.1na anortusr�sdeer grr,<�edtnhl n pars atKmwssu—d ,smrr.,d pd.. mli�nsnen nr�>rusnsamsd�mss 80083
q Ia4pgLns Mgrryhenolinn pmtcrnu,Nm ':� 4451 St. Luce Blvd.
rnnmsleaalgn:antlryMrynhe�behdirctlrshtrhelIke ImDt9 DIM, hr7TMtrLigDnlpn,nLnsdp7s8gateohrylrlro}lanrtmlftrdlscsnenadmlhiM1i
(opyrightm2016A-IPoaffrasses-AethonyLTonba01,P.LReptadoaianalf9sdommeaf,inanykrm,isprohihednuhauttbewinenpermissianhemAdtoolfrusses-WaayLfonboIII,P.I. Fort Pierce, FL 34946
b
Truss
Truss Type
Qty
778
�60
MG02
Half Hip Girder
1
��Job
A0129164
rence (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
4x6
4x4 II
Run: 8.120 s Aug 16 2017 Print: 8.120 s Aug 16 2017 MiTek Industries, Inc. Tue Oct 17 10*45:09 2017 Page 1
I D:IMTa5W VdxJ7_cF0OWg_MyeyiLhV-5VJNsg88VwmQktfyB0lu6wFOfvRbG6DNhJ?CZWySYMB
Plate Offsets (X Y)— [2:0-2-0 0-0-51
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Well
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.64
Vert(LL)
0.05
4-5
>999
240
MT20 244/190
TCDL 16.0
Lumber DOL
1.25
BC 0.69
Vert(TL)
-0.09
4-5
>605
240
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.11
Horz(TL)
-0.00
4
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
Matrix -MS
Weight: 39 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc
puriins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation ouide.
REACTIONS. (lb/size)
4 =
747/Mechanical
5 =
593/0-8-0 (min. 0-1-8)
Max Horz
5 =
197(LC 5)
Max Uplift
4 =
-763(LC 8)
5 =
-238(LC 8)
Max Grav
4 =
963(LC 32)
5 =
593(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
3-4=-301/360
BOT CHORD
5-6=-294/284, 6-7=-294/284,
7-8=294/284, 4-8=-294/284
WEBS
1-4=252/275
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=30ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 763 lb uplift at
joint 4 and 238 lb uplift at joint 5.
7) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 213
lb down and 252 lb up at 4-10-4 on top chord, and
473 lb down and 254lb up at 1-11-4, and 473lb down
and 253 lb up at 3-11-4, and 122 lb down and 155 lb
up at 4-4-8 on bottom chord. The design/selection of
such connection device(s) is the responsibility of
others.
8) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-72, 2-3=-72, 4-5=-20
Concentrated Loads (lb)
Vert: 3=-46(F)6=-473(B)7=-473(B)8=85(F)
6v;try •nersrrnratreM■er•t•I r>•2rnoss3rnu ramtntu:t misnor6tnma[7ara1sta2A;:6tu�irA�,. tniyltap rmxeY!eadnetedef n{tf inn Dasi}ttrnuipD[; dnt 7ednyl.6o»r2,r£Wnnn Sltnldotrst.nr t;4siein tdn".t n0,aly
uSluw*flindohrsrkfit IDDOWfeA Anthony T. Tombo 111, P.E.
' aJrudPotinnWmA7f�u+brrrnsdidldBeGam;BaCavfsu5n'vdgrderd6>:dcrDtsv,uho�4adtle7f,e�dd:6allcLyu@rdinL TngpmJdOtinieg6eMae rl3t inst*saJS�uk4+rzg•,a+W'mw elWx{sUG6eGnes«9Sr.3}d 380083 J
++�tacrhapcolrnauY sD�ztrsnur®mr6a§ raw ntpmnns6vLdq('q e13t7icscmnitar}anaagrnsasucerduee df.pacd a mlttu 2tngom�nutmnea.t csDt�n:tRntrapriruaa,rmih*ftmVd'n 4451 St. Lucie Blvd.
Fort Pierce, FL 34946
o3gtSuMod1}tGGhgeHgn6�rtorr}tRraSts inlyd mtnnrDnil,Fgwrb9o14ttnA�t,sryex,aT,nspaeaFexdmi>frmt. ttalrmcsmctdalrN.
topyrilitm2916A-1[ocllrerus-AeiEoeyl.lomboIII,Pi Eprodauionofi6isdammenl,iaonpram,isprv6i6irrd.e6ommerritteopmmissioofiomA-lteoilnrses-Aot6myl.lom5n0,P.E.
JANUARY 17, 2017
TYPICAL HIP / KING JACK CONNECTION I STDTLO1
CORNERSET GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 175 mph, ASCE
7-10, Exp. B, C up to 60' Mean Roof Height
z \ and Exposure D up to 30' Mean Roof Height.
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
Attach King Jack w/ (3) 16d Toe
,Nails @ TC & 24" Strap w/ (6)
10d x 1.5" ea. end @ BC
Attach End Jack's
w/ (4) 16d Toe Nails @ TC
& (3) 16d Toe Nails @ BC
0
ti
3ch Corner Jack's
(2) 16d Toe Nails
), TC & BC (Typ)
w,
far ed.di...flysbmm..t,Nayfarm,isp oUPWI'MmItewebtm
Attach Corner Jack's
w/ (2) 16d Toe Nails @ TC &
BC (Typ)
FEBRUARY 17, 2017
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409.1010
ALTERNATE GABLE END BRACING DETAIL
ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORO
V-3'MAX.
OIAG. BRACE
AT 1/3 POINTS
IF NEEDED
IT IS THE RESPONSIBILITY OF THE BLDG.
DESIGNER OR THE PROJECT ENGINEER/ARCF
TO DESIGN THE CEILING DIAPHRAGM AND I1
ATTACHMENT TO THE TRUSSES TO RESIST j
OUT OF PLANE LOADS THAT MAY RESULT F
THE BRACING OF THE GABLE ENDS.
STDTL03
2X6 DIAGONAL BRACE SPACED 48'
O.C. ATTACHED TO VERTICAL WITH
(4) - 16d NAILS, AND ATTACHED TO
BLOCKING WITH (5) - 10d COMMONS.
NAIL DIAGONAL BRACE TO
PURLIN WITH TWO 16d NAILS.
2X4 PURLIN FASTENED TO FOUR
TRUSSES WITH (2) - 16d NAILS
EACH. FASTEN PURLIN TO BLOCKING
W/ (2) - 16d NAILS (MIN.).
PROVIDE 2X4 BLOCKING BETWEEN
THE TRUSSES SUPPORTING THE
BRACE AND THE TWO TRUSSES ON
EITHER SIDE AS NOTED. TOENAIL
BLOCKING TO TRUSSES WITH (2) -
10d NAILS AT EACH END. ATTACH
DIAGONAL BRACE TO BLOCKING WITH
(5) - 10d COMMON WIRE NAILS.
CEILING SHEATHING
BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES
STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED:
METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE
OF THE STRUCTURAL GABLE AND FASTEN PER THE
FOLLOWING NAIL SCHEDULE.
METHOD 2: ATTACH 2X- SCABS TO THE FACE OF EACH VERTICAL
MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING
NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG
SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL
NAILING SCHEDULE:
- FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE
7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131'
X 3') NAILS SPACED 6' O.C.
- FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-98, 02, 05), 150
MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d
(.131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM).
MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. AL
BRACING METHODS SHOWN ON PAGE 1 ARE VALID
AND ARE TO BE FASTENED TO THE SCABS OR
VERTICAL STUDS OF THE STANDARD GABLE TRUSS
ON THE INTERIOR SIDE OF THE STRUCTURE.
UKAL
TRUSS
..." . 3TU❑
STRUCTURAL / AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING
GABLE TRUSS /N MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF
THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS.
THE BRACING SHOWN IN THIS DETAIL IS FOR
I VERTICAL/STUDS ONLY.
NOTE: THIS DETAIL IS TO BE USED ONLY FOR/
STRUCTURAL GABLES WITH INLAYED
STUDS. TRUSSES WITHOUT INLAYED
STUDS ARE NOT ADDRESSED HERE.
STANDARD GABLE /
TRUSS
I
ACK
DULY 17, 2017 I STANDARDCONNECTIONBDETAI TRUSS I STDTL04 I
THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WIND CONDITIONS:
ASCE 7-98, ASCE 7-02, ASCE 7-05, ASCE 7-10 WIND STANDARDS UNDER ALL ENCLOSURE AND EXPOSURE
CONDITIONS AS LONG AS NO UPLIFT EXCEEDS 377 LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN
DRAWING FOR UPLIFTS.
NOTE: THIS DETAIL IS VALID FOR ONE PLY TRUSSES SPACED 24- O.C. OR LESS.
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
PIGGYBACK TRUSS
REFER TO ACTUAL TRUSS DESIGN DRAWING FOR
ADDITIONAL PIGGYBACK TRUSS INFORMATION.
SPACE PURLINS ACCORDING TO THE MAXIMUM
SPACING ON THE TOP CHORD OF THE BASE TRUSS
(SPACING NOT TO EXCEED 24. O.CJ A PURLIN
TO BE LOCATED AT EACH BASE TRUSS JOINT.
ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 2' X 8'
TEE -LOCK MULTI -USE CONNECTION PLATES SPACED 48' O.C. PLATES
SHALL BE PRESSED INTO THE PIGGYBACK TRUSS AT 48' O.C.
STAGGERED FROM EACH FACE AND NAILED TO THE BASE TRUSS WITH
FOUR (4) 6d (1.5' X 0.099') NAILS IN EACH PLATE TO ACHIEVE A MAXIMUM
UPLIFT CAPACITY OF 377 LBS. AT EACH 2" X 8' TEE -LOCK MULTI -USE
CONNECTION PLATE. (MINIMUM OF 2 PLATES)
ATTACH EACH PURLIN TO THE TOP CHORD OF
THE BASE TRUSS.
(PURLINS AND CONNECTION BY OTHERS)
BASE TRUSS
REFER TO ACTUAL TRUSS DESIGN DRAWING FOR
ADDITIONAL BASE TRUSS INFORMATION.
JULY 17, 2017
TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772AO9-1010
VALLEY TRUSS
(TYPICAL)
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS 6' O.C.
GABLE END, COMMON
TRUSS, OR GIRDER
TRUSS
DETAIL A
ATTACH 2X4 CONTINUOUS #2
SYP TO THE ROOF W/ TWO USP
WS45 (1/4- X 4.5-) WOOD SCREWS
INTO EACH BASE TRUSS.
wtv4 u
GENERAL SPECIFICATIONS:
1. NAIL SIZE = W X 0.131' =10d
2. WOOD SCREW = 4.5' WS45 USP OR EQUIVALENT.
3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES.
4. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM) AND
SECURE TO BASE TRUSSES AS PER DETAIL'A'.
5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
6. NAILING DONE PER NDS - 01.
7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
BASE TRUSSES
"�'_E END, COMMON
3S, OR GIRDER TRUSS
TRUSS CRITERIA:
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
MAX SPACING = 24' O.C. (BASE AND VALLEY)
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
faq��n&g'seJUFlid.tz�q NipvaTmsdjfJ:a l�:xedc�Eri� AO
ttpsdauio®d Ihas deersreay is enrh�ap is pwAZeed xuhad Ide stile
JULY 17, 2017 1 TRUSSED VALLEY SET DETAIL I STDTL06
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
VALLEY TRUSS
(TYPICAL)
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS 6' O.C.
GABLE END, COMMON
TRUSS, OR GIRDER
TRUSS
DETAIL A
(NO SHEATHING) N.T.S.
GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3` X 0.131' =10d
2. WOOD SCREW = 3' WS3 USP OR EQUIVALENT.
3. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM) AND SECURE PER DETAIL
W.
4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN
DRAWINGS.
5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT
TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING.
6. NAILING DONE PER NOS - 01.
7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C.
P �2
SEE DETAIL `A'
BELOW (TYP.)
BASE TRUSSES
GABLE END, COMMON
TRUSS, OR GIRDER
VALLEY TRUSS TRUSS
(TYPICAL)
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
ATTACH 2X4 CONTINUOUS #2
MAX TOP CHORD TOTAL LOAD = 50 PSF
SYP TO THE ROOF W/ TWO USP
MAX SPACING = 24` O.C. (BASE AND VALLEY)
WS3 (1/4- X 3-) WOOD SCREWS
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
INTO EACH BASE TRUSS.
LLEY SET DET
JULY 17, 2017 I TRUSSED W ND VELOCITY) AIL STDTL07
i�
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
r_v■r_l
WIND DESIGN PER ASCE 7-98, ASCE 7-
WIND DESIGN PER ASCE 7-10: 170 MPI
MAX MEAN ROOF HEIGHT = 30 FEET
CATERGORY It BUILDING
EXPOSURE B OR C
WIND DURATION OF LOAD INCREASE:
MAX TOP CHORD TOTAL LOAD = 50 PS
MAX SPACING = 24- O.C. (BASE AND V/
SUPPORTING TRUSSES DIRECTLY UNUtK VALLtr r KUssts onus r nt
DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' -10' ON AFFECTED
TOP CHORDS.
NOTES:
1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES.
2. THIS DETAIL IS NOT APPLICABLE FOR SPFS SPECIES LUMBER.
FOR BEVELED BOTTOM
CHORD, CLIP MAY BE APPLIED
TO EITHER FACE.
CLIP MAY BE APPLIED
TO THIS FACE UP TO A
NON -BEVELED MAXIMUM 6112 PITCH
BOTTOM CHORD u I
NON -BEVELED
BOTTOM CHORD
CLIP MUST BE APPLIED TO
THIS FACE WHEN PITCH
EXCEEDS 6112 (MAXIMUM
12112 PITCH)
ono
tepsadestiaa d8fis dacemeN, i,J asry farm, is pro4'3:sd ra3eatt6e villen perausf'mn
FEBRUARY 17, 2017 1 STANDARD GABLE END DETAIL I STDTL08
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TYPICAL 2X4 L-BRACE
NAILED TO 2X4 VERTICALS
7z;
VER1
STUD
SECTION B-B
TRUSS GEOMETRY AND CONDITIONS
SHOWN ARE FOR ILLUSTRATION ONLY.
VERTICAL
2X6 SP OR SPF
STUD
#2 DIAGONAL
BRACE
(4) - 16d
NAILS
16d NAILS
SPACED 6' O.C.
(2) lOd NAILS
INTO 2X6
2X6 SP OR
SPF #2
2X4 SP OR
SPF #2
TYPICAL HORIZONTAL
BRACE NAILED TO
2X4 VERTICALS
SECTION A -A
W/(4) - 10d NAILS
DIAGONAL BRACE 4' - 0' O.C. MAX.
SEE INDIVIDUAL ENGINEERING DRAWINGS
FOR TRUSS DESIGN CRITERIA.
12 PROVIDE 2X4 BLOCKING BETWEEN
Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED.
TOENAIL BLOCKING TO TRUSSES
* WITH (2) - 10d NAILS AT EACH ENO.
ATTACH DIAGONAL BRACE TO
BLOCKING WITH (5) - 10d NAILS
(4) 8d NAILS MINIMUM, ROOF
3X4= PLYWOOD SHEATHING TO / SHEATHING
2X4 STO SPF BLOCK
v
i(DIAGONAL BRACING ** L - BRACING REFER
REFER TO SECTION A -A TO
/
SECTION B-B 24' MAX.
NOTE:
/
1. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS.
2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE
(2) - 10d
END TRUSS AND WALL TO 12, MAX.
NAILS
BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT.
3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG.
ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF
-
SYSTEM.
4. L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR
/
BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C.
TRUSSES 0 24' O.C.
5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM
/
AT 4' - 0' O.C.
6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN
2X6 DIAGONAL BRACE
WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT
SPACED 48. O.C. ATTACHED
THE MIOSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE
TO VERTICAL WITH (4) -
STUDS WITH (3) IOd NAILS THROUGH 2X4 (REFER TO SECTION A -A)
16d NAILS, AND ATTACHED
7. GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240.
TO BLOCKING WITH (5) -
B. THIS DETAIL ODES NOT APPLY TO STRUCTURAL GABLES. DIAG. BRACE
IOd NAILS.
S. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS
TRUSSES. IF NEEDED
10. 10d AND 16d NAILS ARE 0131'X3.0' AND 0131'X35' COMMON WIRE NAILS
HORIZONTAL BRACE
RESPECTIVELY.
(SEE SECTION A -A)
11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12
BY SPIB/ALSO.
MINIMUM STUD
SIZE SPECIES
AND GRADE
STUD
SPACING
WITHOUT
BRACE
2X4
L - BRACE
DIAGONAL
BRACE
(2) DIAGONAL
BRACES AT
1/3 POINTS
MAXIMUM STUD LENGTH
2X4SP#31STUD
12'0.C.
3-8-10
5-0.11
6-6-11
11-1-13
2X4 SP #31 STUD
16' O.C.
3-3-10
4-9-12
6.6-11
9-10-15
2X4 SP #31 STUD
24' O.C.
2-8-6
3-11-3
54.12
8-1-2
2X4SP#2
12.O.C.
3-10-15
5-0-11
6-6-11
11-8-14
2X4 SP #2
16' O.C.
3-0-11
4-9-12
6-6-11
10.8-0
2X4 SP #2
24' O.C.
3-1-4
3-11-3
6-2-9
9-3-13
DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE
EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO
BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE
WITH 10d NAILS 6' O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER
90% OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2.
MAX MEAN ROOF HEIGHT = 30 FEET
EXPOSURE B OR C
ASCE 7-10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING.
DURATION OF LOAD INCREASE :1.60 CONNECTION OF BRACING IS BASED ON MWFRS.
END WALL
FEBRUARY 17, 2017
WITH 2X BRACE ONLY
ri
NOTES:
T-BRACING / I -BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING
IS IMPRACTICAL. T-BRACE / I -BRACE MUST COVER 907 OF WEB LENGTH.
■� €
THIS DETAIL NOT TO BE USED TO CONVERT T-BRACE / I -BRACE WEBS TO
CONTINUOUS LATERAL BRACED WEBS.
A-1 ROOF TRUSSES
4461 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
NAILING PATTERN
T-BRACE SIZE
NAIL SIZE
NAIL SPACING
2X4 OR 2X6 OR 2X8
10d
6" O.C.
NOTE. NAIL ALONG ENTIRE LENGTH OF T-BRACE / I -BRACE (ON
TWO-PLY TRUSSES NAIL TO BOTH PLIES)
\\ \ NAILS
STDTL09
BRACE
SIZE FOR ONE -PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T-BRACE
2X4 I -BRACE
2X6
2X6 T-BRACE
2X6 I -BRACE
2X8
2X8 T-BRACE
2X8 [-BRACE
BRACE
SIZE FOR TWO-PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 20
2X4 T-BRACE
2X4 I -BRACE
2X6
2X6 T-BRACE
2X6 I -BRACE
2X8
2X8 T-BRACE
2X8 I -BRACE
T-BRACE / I -BRACE MUST BE SAME SPECIES
AND GRADE (OR BETTER) AS WEB MEMBER.
NAILS
WEB
NAILS
I -BRACE
NAILS
WEB
T-BRACE
SECTION DETAILS
FEBRUARY 17, 2017
LATERAL BRACING RECOMMENDATIONS I STDTL10
TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS,
2XG 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET
ALONG A FLOOR TRUSS.
NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE
TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY
A-1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW.
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34945 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE
772-409-1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS
FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY
CONNECTED, BY OTHERS, AT THE ENDS.
INSERT WOOD SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (DO NOT
USE METAL FRAMING ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS)
ANCHOR TO ATTACH WEB WITH (3) - 10d SCAB WITH (3) - 10d r
TO TOP CHORD NAILS (0131' X 3') NAILS (0131' X 3'). I NATTACH AILS ( TO XRT1'AdL
BLOCKING BEHIND THE VERTICAL
WEB IS RECOMMENDED WHILE
NAILING THE STRONGBACK
USE METAL FRAMING
ANCHOR TO ATTACH
TO BOTTOM CHORD
TRUSS
ATTACH TO VERTICAL
WEB WITH (3) - 10d
NAILS (0131' X 3')
ATTACH 2X4 VERTICAL
TO FACE OF TRUSS.
FASTEN TO TOP AND
BOTTOM CHORD WITH
(2) - 10d NAILS (0131'
X 3') IN EACH CHORD
ATTACH TO VERTICAL
SCAB WITH (3) - 10d
NAILS (0131' X 3')
2X6 4' - 0' WALL
STRONGBACK (TYPICAL SPLICE) (BY OTHERS)
ATTACH TO CHORD
WITH (2) #12 X 3'
WOOD SCREWS
(0.216' DIA.)
INSERT SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (DO NOT
USE DRYWALL TYPE SCREWS)
THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT,
DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB
CENTERED ON THE SPLICE AND JOINED WITH (12) - IOd NAILS (0131' X 3')
EQUALLY SPACED.
ALTERNATE METHOD OF SPLICING:
OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) -
10d NAILS (0131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY
WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL).
BLOCKING
(BY OTHERS)
FEBRUARY 17, 2017 1 LATERAL TOE -NAIL DETAIL I STDTL11
A;1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409.1010
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45' WITH THE MEMBER
AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN
THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS
SHOWN).
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL
BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO
SPECIES FOR MEMBERS OF DIFFERENT SPECIES.
TOE -NAIL SINGLE SHEAR VALUES
PER NOS 2001 (LB/NAIL)
OIA
SP
OF
HF
SPF
SPF-S
131
88.0
80.6
69.9
68.4
59.7
o
.135
93.5
85.6
74.2
72.6
63.4
J
.162
108.8
99.6
86.4
84.5
73.8
ri
.128
74.2
67.9
58.9
57.6
50.3
c�
Z
0
J
.131
75.9
69.5
60.3
59.0
51.1
in
.148
81.4
74.5
64.6
63.2
52.5
N
M
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD
FOR LOAD DURATION INCREASE OF 115:
3 (NAILS) X 845 (LB/NAIL) X 1.15 (OOL) = 2915 LB MAXIMUM CAPACITY
ANGLE MAY
VARY FROM
30' TO 60'
45.00°
ANGLE MAY
VARY FROM
30' TO 60'
THIS DETAIL IS ONLY APPLICABLE TO
THE THREE ENO DETAILS SHOWN BELOW.
VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY.
SIDE VIEW
(2X3) 2 NAILS
NEAR SIDE
NEAR SIDE
SIDE VIEW
(2X4) 3 NAILS
NEAR SIDE
NEAR SIDE
NEAR SIDE
45.00'
SIDE VIEW
(2X3) 2 NAILS
NEAR SIDE
NEAR SIDE
NEAR SIDE
NEAR SIDE
ANGLE MAY
VARY FROM
30' TO 60'
45.00°
lc
FEBRUARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL 1 STDTL12
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE. FL 34946
772-409-1010
THIS DETAIL SHALL BE USED FOR A CONNECTION
RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER
IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS.
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE
MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION.
TOE —NAIL WITHDRAWAL VALUES
PER NDS 2005 (LB/NAIL)
DIA.
SP
DF
HF
SPF
SPF—S
L7
.131
59
46
32
30
20
Z
O
—1
.135
60
48
33
30
20
•
('7
.162
72
58
39
37
25
J
�
CD
.128
54
42
28
27
19
O
Z
Z
OJ
.131
55
43
29
28
19
LLI
.148
62
48
34
31
21
-]
Lf)
J_
N
Q
M
Z
120
51
39
27
26
17
z
.128
49
38
26
25
17
O
J
.131
51
39
27
26
17
M
.148 1
57
44
31
28 1
20
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (0.162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE
FOR WIND DOL OF 1.33:
3 (NAILS) X 37 (LB/NAIL) X 133 (DOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
FOR WIND DOL OF 1.60:
3 (NAILS) X 37 (LB/NAIL) X 1.60 (DOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LBS) BUILDING
DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION.
*** USE (3) TOE -NAILS ON 2X4 BEARING WALL
*** USE (4) TOE -NAILS ON 2X6 BEARING WALL
NEAR SIDE
FAR S]
SIDE VIEW
)E
TOP PLATE
OF WALL
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
END VIEW
IL
NAIL
NAIL
FEBRUARY 5, 2016
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
lw*M:4cl
TYP 2x2 NAILER ATTACHMENT I STDTL13
2x2 NAILER ATTACHMENT
GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 170 mph, ASCE
7-10, 29'-0" Mean Height, Exp. B, C or D.
April 11, 2016
-zzzZ:Z:zz::,.
4`p
zz
�zz z z z z
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TYPICAL ALTERNATE BRACING DETAIL
FO EXTERIOR FLAT GIRDER TRUSS
(4) 12d
TRUSS 2411 O.C.
UPLIFT CONNECTION
(SEE ROOF TRUSS)
EXTERIOR FLAT
GIRDER
12
VARIES
STDTL14
(4) .12d
MAX 30" (2'-6")
2x6 #2 SP (Both Faces)
24" O.C.
SIMPSON H5
FEBRUARY 17, 2017 I STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND I STDTL15 I
DAMAGED OR MISSING CHORD SPLICE PLATES
A-1 ROOF TRUSSES
4451 ST, LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TOTAL NUMBER
OF NAILS EACH
SIDE OF BREAK
X
(INCHES)
MAXIMUM FORCE (LBS) 157 LOAD DURATION
SP
OF
SPF
HF
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
20
30
24'
1706
2559
1561
2342
1320
1980
1352
2028
26
39
30'
2194
3291
2007
3011
1697
2546
1738
2608
32
48
36'
2681
4022
2454
3681
2074
3111
2125
3187
38
57
42'
3169
4754
2900
4350
2451
3677
2511
3767
44
66
48'
3657
5485
3346
5019
2829
4243
2898
4347
s DIVIDE EQUALLY FRONT AND BACK
ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF
THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE
ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' DIA. X 3').
STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN
THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE.
THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS)
THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C
•10d NAILS NEAR SIDE
+ 10d NAILS FAR SIDE
X0d
-9
TRUSS CONFIGURATION
AND BREAK LOCATIONS
FOR ILLUSTRATIONS ONLY
THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO
THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT
AND A MINIMUM OF G' FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE).
DO NOT USE REPAIR FOR JOINT SPLICES
NOTES:
1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR
DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE
TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN
THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF
SUPPORTING THE LOADS INDICATED.
2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR
AND HELD IN PLACE DURING APPLICATION OF REPAIR.
3. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID
UNUSUAL SPLITTING OF THE W00D.
4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID
LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
5. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY.
G. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS.
FEBRUARY 17, 2017 1 SCAB APPLIED OVERHANGS I STDTL16
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TRUSS CRITERIA:
LOADING: 40-10-0-10
DURATION FACTOR: 115
SPACING: 24. O.C.
TOP CHORD: 2X4 OR 2X6
PITCH: 4/12 - 12/12
HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL
END BEARING CONDITION
NOTES:
1. ATTACH 2X_SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS
WITH TWO ROWS OF 10d COMMON WIRE NAILS 048' DIA. X 3') SPACED 6' O.C.
2. THE ENO DISTANCE,.EOGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO
AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
2X SC
NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED
WHEN OVERHANG HAS BEEN BROKEN OFF.
IMPORTANT
THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24'
O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD
LOADS NOT EXCEEDING 50 PSF.
TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY.
REFER TO INDIVIDUAL TRUSS DESIGN
FOR PLATE SIZES AND LUMBER GRADES
-A
A^1 ROOF
A FLORIDA CORPORATION
Important motes / Please Review Prior to Truss Installation:
1) Trusses are to be handled, installed and braced in accordance to the following standards: ANSI/TIP 1-2007;
WTCA 1-1995 — "Standard Responsibilities in the Design Process Involving Metal Plate Connected Wood Trusses",
and 'SCSI 1-03 Guide to Good Practice For Handling, Installing, & Bracing of Metal Plate Connected Wood
Trusses" published by WTCA and Truss Plate Institute. Any of this material can be obtained by contacting A-1 Roof
Trusses. Spanish versions are also available.
2) All temporary and permanent bracing design, connection, material, and labor by others.
3) Truss designs are for an individual component, not for a truss system. Reactions and uplifts may vary from building
designers calculated loads. The building designer is ultimately responsible for clarifying any discrepancies.
4) If provided by truss manufacturer, any engineered beams provided have been sized using information design
guides or software provided by the beam manufacturer. The building designer should verify all loads uplifts, and
bearing requirements. Truss manufacturer is not responsible for specifying beams, other than those provided by
truss manufacturer.
5) Unless specified, roof trusses are not designed for any additional attic storage loads.
6) On flat surfaces, adequate drainage must be provided to avoid ponding.
7) It is the builder's responsibility to assure there is adequate room for A/C ducts, electrical wiring and plumbing runs
to assure they do not interfere with the truss chords. (Roof and floor.) Truss chords and webs cannot be cut. Attic
access opening should be located between trusses unless otherwise noted.
8) Unless specified, valley framing design, connection, material and labor to be supplied by the builder.
9) Attached drawings are standard details that cover most installation standards. Structural details provided by the
building designer supersede any attached details.
1.0) Trusses are not designed to carry the chimney, cupola, steeple, or other structures unless specified. Structure should
be framed through the trusses to be supported by the foundation. In cases where trusses are designed to carry the
structure above all loads and uplifts MUST be verified by building designer. Connection of structure to trusses must
be provided by the building designer.
1 1) The specific engineered truss drawings are subject to other terms, conditions, and details on the truss placement plan
and/or individual truss design drawings.
12) Trusses are designed to carry ONLY the specified loads on the engineered drawings. Point loads for materials,
erection personnel, equipment, whether temporary or permanent, are not allowed unless specified on sealed
engineered_ drawings.
Any questions or comments feel free to contact A-1 Roof Trusses at 772-409-1010.
4451 St. Lucie Blvd., Fort Pierce, FL 34946
772-409-1010 Office 772-409-1015 Fax
--www.A1truss.com
�USP
STRUCTURAL
CONNECTORSp
A MI OIC Company
Hanapm
Allowable Load (lbs)
DF-L/SP
LSL
LVL
PSL
SPF
I -JOIST
LISP
160%
Label
Stock No.
Code Reports
100%
115%
125%
Uplift
100%
100%
100%
100%
1 10D%
Fastener Schedule
T1
JUS24
1881,
655
750
820
510
-
-
(4) -10d (Header)
FL821.39,
(2) -10d (Joist)
11-
0510.01,
RR 25779
LUS24
670
765
825
490
-
-
-
_
(4) - 10d (Header)
(2) -10d (Joist)
T2
JUS26
1881,
850
975
1060
1115
(4) - lOd (Header)
FL821.42,
(2) - lOd (Joist)
11-
0510.01,
RR 25779
LUS26
865
990
1070
1165
-
-
-
-
_
(4)- 10d(Header]
(2) -10d (Joist)
T3
MSH422
1831,
2025
2025
2025
(22) -10d (Face - Face Max Nailing)
FL822.36,
(6) -10d (Face - Top Max Nailing)
08-
(6) -10d (Joist - Face Max Nailing)
0303.06,
(6) -10d (Joist -Top Max Nailing)
RR 25836
(4) -10d (Top - Top Max Nailing)
13116-R
THA422
2245
2245
2245
-
-
_
_
_
_
(6) -16d (Corried Member -Face Mount)
(6) -10d (Carried Member- Top Flange)
(22) - I6d (Face - Face Mount)
(2) -16d (Face - Top Flange)
(4) -16d (Top - TO Flange)
THA1412
1835
1835
1835
-
-
_
_
_
-
(21 - 20dx 1-112 or2-10dx 1-I12(Carried Member)
(20) -10d or (2) - lod (Face)
(4) -10d (Top)
T4
THD26
1781,
2485
2855
3060
2170
(18) -16d (Face)
FL13285.35,
(12) -10d x 1-1/2 (Joist)
06-
0921.05,
RR 25843
HTU26
2940
3340
3600
1555
-
-
_
_
_
(11) -10d x 1-112 (Carried Member)
(201-10d x 1-112 (Carried Member- Max Nailing)
(20) -16d x 1-112 (Carrying Member)
(20) -16d x 1-112 (Carrying Member- Max Nailing)
uP
STRUCTURAL
CONNECTORS'
A MtTek-Company
Allowable Load (Ibs)
DF-L/SP
LSL
LVL.
PSL
SPF
I -JOIST
160%
LISP
Label
Stock No.
Code Reports
100%
115%
125%
Uplift
100%
100%
100%
100%
100%
Fastener Schedule
T5
THD26-2
1781,
2540
2920
3175
2285
(18) - 16d (Face)
FL13285.35,
(12) -10d (Joist)
06-
0921.05,
RR 25843
13116-R
HHUS26-2
2785
3155
3405
1550
-
-
-
_
_
(14)-16d(Foce)
(6) -16d (Joist)
HTU26.2
2940
3340
3600
2175
-
-
-
-
_
(20)- 10d(Carried Member -Max Nailing)
(20) -16d (Carrying Member- Max Nailing)
T6
THD28
1781,
3865
3965
3965
2330
(28) -16d (Face)
FL13285.35,
(16) -10d x 1-1/2 (Joist)
06-
0921.05,
RR 25843
HTU28
3820
4340
4680
2140
-
-
-
-
_
(25)-lod xl-112(Carried Member -Max Nailing)
(26) -16d (carrying Member- Max Nailing)
T7
THD28-2
1781,
3950
4540
4935
2595
(28) - 16d (Face)
FL13285.35,
(16) -10d (Joist)
06-
0921.05,
RR 25843
13116-R
HHUS28-2
4210
4770
5140
2000
-
-
-
-
-
(22)-16d[Face)
(8) -16d (Joist)
HTU28.2
3820
4340
4680
3485
-
-
-
-
_
(26)- 10d(Carried Member -Max Nailing)
(26)- 16d(Carrying Member -Max Nailing) -
T8
THD46
1781,
2540
2920
3175
2285
(18) - 16d (Face)
FL13285.35,
(12) -10d (Joist)
06-
0921.05,
RR 25843
13116-R
HHUS46
2790
3160
3410
1550
-
-
-
-
-
(14) -16d (Face)
(6)-16d (Joist)
USP
STRUCTURAL
CONNECTORS'
A Mfrek' Company
Haneers
Allowable Load (lbs)
DF-L/SP
LSL
LVL
PSL
SPF
I -JOIST
160%
LISP
Label
Stock No.
Code Reports
100%
115%
125%
Uplift
100%
100%
100%
100%a
100%
Fastener Schedule
T9
THD48
1781,
3950
4540
4935
2595
(28) -16d (Face)
FL13285.35,
(16) -10d (Joist)
06-
0921.05,
RR 25843
13116-R
HHUS48
4210
4770
5140
2000
-
-
_
_
(22)-16d(Foce) -
(8) -16d (Joist)
T10
THDH26-2
1881,
3915
4505
4795
2235
(20) -16d (Face)
FL821.75,
(8) -10d (Joist)
06-
0921.05,
RR 25779
13116-R
HGUS26.2
4355
4875
5230
2155
-
-
-
-
(20) -16d (Face)
(8) -16d (Joist)
T11
THDH26-3
1881,
3915
4505
4795
2235
(20) -16d (Face)
FL821.75,
(8) -10d (Joist)
06-
0921.05,
RR 25779
HGU526-3
4355
4875
5230
2155
-
-
_
_
_
(20) -16d (Face)
(8) -16d (Joist)
T12
THDH28-2
1881,
6535
7515
8025
2665
(36) -16d (Face)
FL821.77,
(10) -16d (Joist)
RR 25779
13116-R
HGU528-2
7460
7460
7460
3235
-
-
-
_
(36) -16d (Face)
(12) -16d (Joist)
T13
THDH28-3
1881,
6770
7785
8025
2665
(36) -16d (Face)
FL821.75,
(10) -16d (Joist)
06-
0921.05,
RR 25779
HGUS28-3
7460
7460
7460
3235
-
-
_
_
(36) -16d (Face)
(12) -16d (Joist)
US P
STRUCTURAL
CONNECTORS
A MITek' Company
Fastener Comparison Table
Connector Schedule
Group
Label
LISP Stock No
Required Fasteners
Reference No
Required Fasteners
(4) - lad (Header)
(4) - lad (Header)
-
T1
JUS24
LUS24
(2) - lad (Joist)
(2) -10d (Joist)
(4) -1ad (Header)
(4) - lad (Header)
-
T2
JUS26
LUS26
(4) - lad (Joist)
(4) - lad (Joist)
(22) - lad (Face - Face Max Nailing)
(6) -16d (Carried Member - Face Mount)
(6) - lad (Face - Top Max Nailing)
(6) -16d (Carried Member - Top Flange)
-
T3
MSH422
(6) - lad (Joist - Face Max Nailing)
THA422
(22) -16d (Face -Face Mount)
(6) - lad (Joist -Top Max Nailing)
(2) -16d (Face - Top Flange)
(4) - lad (Top - Top Max Nailing)
(4) -16d (Top - Top Flange)
(11) -10d x 1-112 (Carried Member)
(18) -16d (Face)
(12) - lad x 1-1/2 (Joist)
(20) - Iod x 1-112 (Carried Member- Max Nailing)
-
T4
THD26
HTU26
(20) -16d (Carrying Member)
(20) -16d (carrying Member -Max Nailing)
(18) -16d (Face)
(14) -16d (Face)
-
T5
THD26-2
HHUS26-2
(12) - lad (Joist)
(6) -16d (Joist)
(28) -16d ( Face)
(26) -10d x 1-112 (Carried Member - Max Nailing)
-
T6
THD28
HTU28
(16) - lad x 1-1/2 (Joist)
(26) -16d x 1-112 (Carrying Member - Max Nailing)
(28) -16d (Face)
(22) -16d (Face)
-
T7
THD28-2
HHUS28-2
(16) - lad (Joist)
(8) -16d (Joist)
(18) - 16d (Face)
(14) -16d (Face)
-
T8
THD46
HHUS46
(12) - lad (Joist)
(6) -16d (Joist)
(28) -16d (Face)
(22) -16d (Face)
-
T9
THD48
HHUS48
(16) - lad (Joist)
(8) -16d (Joist)
(20) -16d (Face)
(20) -16d (Face)
-
T10
THDH26-2
HGUS26-2
(8) -16d (Joist)
(8) -16d (Joist)
(20) -16d (Face)
(20) -16d (Face)
-
T11
THDH26-3
HGUS26-3
(8) -16d (Joist)
(8) -16d (Joist)
(36) -16d (Face)
(36) -16d (Face)
-
T12
THDH28-2
HGUS28-2
(10) -16d (Joist)
(12) -16d (Joist)
(36) -16d (Face)
(36) -16d (Face)
-
T13
THDH28-3
HGUS28-3
(10) - l6d (Joist)
(12) -16d (Joist)
....... ...
usp
STRUCTURAL,
CC NNECTOR$
A MIT6k'Company
44,
JUS24
JUS26
MSH422
rXi
THD26
THD26-2
THD28
Z
THD28-2
THD46
THDH26-2
4o.
,THDH26-3
THDH28-2
THDH28-3
JANUARY 8, 2016 I TYPICAL HIP / KING JACK CONNECTION I ST-CRNRST & LVL NAILIN
LVL NAILING SCHEDULE
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
CORNERSET GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 170 mph, ASCE
7-10, 29'-0" Mean Height, Exp. B, C or D.
Attach King Jack w/ (2) 16d Toe
Nails @ TC & 24" Strap w/ (6)
10d. x 1.5" ea. end @ BC
Attach End Jack's Attach Corner Jack's
w/ (4) 16d Toe Nails @ TC w/ (3) 16d Toe Nails @ TC &
& (3) 16d Toe Nails @ BC (2) 16d Toe Nails @ BC (Typ)
Attach Corner Jack's
w/ (2) 16d Toe Nails
@ TC & BC (Typ)
�b� �r�a�,v7.: �'... ° �::..': alp. r/ ♦ ..
38,BC A2 Z100 00 00'004.612 87 DIF :
FEBRUARY 14, 2012
Standard Gable End Detail
SHEET 2
�lal_J
0 00
0 00
a
MiTek USA, Inc.
MTek USA, Inc. Page 2 of 2
ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD
Trusses (g) 24" ox.
HORIZONTAL BRACE 2x6 DIAGONAL BRACE SPACED 48" O.C.
(SEE SECTION A -A) ATTACHED TO VERTICAL WITH (4) -16d
Roof Sheathinq� \ COMMON WIRE NAILS AND ATTACHED
- d TO BLOCKING WITH (5) - 10d COMMONS.
V-3"
Max.
IT IS THE RESPONSIBILITY OF THE BLDG DESIGNER OR
THE PROJECT ENGINEER/ARCHTECT TO DESIGN THE
CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE
NAIL DIAGONAL BRACE TO
PURLIN WITH TWO NAILS
TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT
MAY RESULT FROM THE BRACING OF THE GABLE ENDS
\
\
2X 4 PURLIN FASTENED TO FOUR TRUSSES
WITH TWO 16d NAILS EACH. FASTEN PURLIN
\
TO BLOCKING W/ TWO 16d NAILS (MIN)
Diag. Brace
at 1 /3 points
PROVIDE 2x4 BLOCKING BETWEEN THE TRUSSES
SUPPORTING THE BRACE AND THE TWO TRUSSES
if needed
ON EITHER SIDE AS NOTED. TOENAIL BLOCKING
TO TRUSSES WITH (2) - 10d NAILS AT EACH END.
ATTACH DIAGONAL BRACE TO BLOCKING WITH
(5) - 10d COMMON WIRE NAILS.
End Wall
--- CEILING SHEATHING
BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES
STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED:
METHOD 1 : ATTACH A MATCHING GABLE TRUSS TO THE INSIDE
FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE
FOLLOWING NAILING SCHEDULE.
METHOD 2: ATTACH 2X-SCABS TO THE FACE OF EACH VERTICAL SCAB ALON(
MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING VERTICAL
NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SIZE, GRADE
AND SPECIES AS THE TRUSS VERTICALS
NAILING SCHEDULE:
FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) OR LESS, NAIL ALL
MEMBERS WITH ONE ROW OF 10d (.131" X 3") NAILS SPACED 6" O.C.
FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL
MEMBERS WITH TWO ROWS OF 10d (.131" X 3") NAILS SPACED 6" O.C. (2X 4 STUDS MINIMUM)
MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1.
/ ALL BRACING METHODS SHOWN ON PAGE 1 ARE
/ VALID AND ARE TO BE FASTENED TO THE SCABS DR
VERTICAL STUDS OF THE STANDARD GABLE TRUSS
ON THE INTERIOR SIDE OF THE STRUCTURE.
INLAYED STUD
L
S
I I
STRUCTURAL AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST
GABLE TRUSS / BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM
CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN
iN IN THIS DETAIL IS FOR THE VERTICAL/STUDS ONLY.
NOTE: THIS DETAIL IS TO BE USED ONLY FOR /
STRUCTURAL GABLES WITH INLAYED
STUDS. TRUSSES WITHOUT INLAYED
STUDS ARE NOT ADDRESSED HERE. /
STANDARD /
GABLE TRUSS
9tiaisir��n�tAl
1.
0.
1 : _A
SERIAL.z`
3B' BCA2 210G00 00 004C'22 97 &: I
---....... - ...._.. ----------
J
STAN'DARD PIGGYBACK
FEBRUARY 14, 2012 I TRUSS CONNECTION DE AIL I ST-PIGGY-PLATE
=00
O DO
LU-U In
MiTek USA, Inc.
This detail is applicable for the following wind conditions:
ASCE 7-98, ASCE 7-02, ASCE 7-05, ASCE 7-10 Wind Standards under
all enclosure and exposure conditions as long as no uplift exceeds 377 lbs.
Refer to actual piggyback truss design drawing for uplifts.
NOTE:
This Detail is valid for one ply trusses spaced 24" O.G. or less.
PIGGYBACK TRUSS
Refer to actual truss'design drawing for
additional piggyback'truss information.
SPACE PURLINS ACCORDING TO THE MAXIMUM
SPACING ON THE TOP CHORD OF THE BASE
TRUSS (SPACING NOT TO EXCEED 24" O.C.).
A PURLIN TO BE LOCATED AT EACH BASE TRUSS JOINT.
MiTek USA, Inc. Page 1 of 1
Attach piggyback truss to the base truss with 3"x8" TEE -LOCK
Multi -Use connection plates spaced 48" o.c. Plates shall be
pressed into the piggyback truss at 48" o.c. staggered from each
face and nailed to the base truss with four (4)- 6d (1.5'xO.099")
nails in each plate to achieve a maximum uplift capacity of 377 Ibs.
at each 3"x8" TEE -LOCK Multi -Use connection plate.
(Minimum of 2 plates)
Attach each purlin to the top chord
of the base truss.
(Purlins and connection by others)
BASE TRUSS
Refer to actual truss design drawing
for additional base truss information.
..................-......_...............................................
.�,. .:
83, :.: ..
p°
A:
-
iris �
. N �1�+'►`�' .
388CA221UaUU00.DDdCf2S7�DF�
a:.
FEBRUARY 14, 2012
UaLJ
0 00
0 00
a
MiTek USA, Inc.
VALLEY TRUSS TYPICAL
SECURE VALLEY TRUSS
W1 ONE ROW OF 10d
NAILS 6" O.C.
TRUSSED VALLEY SET DETAIL ST-VALLEY HIGH WIND2
MiTek USA, Inc. Page 1 of 1
GABLE END, COMMON TRUSS
OR GIRDER TRUSS
GENERAL SPECIFICATIONS
1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 4.5"WS45 USP OR EQUILIVANT
3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES.
4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND
SECURE TO BASE TRUSSES AS PER DETAIL A
5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
6. NAILING DONE PER NDS-01
7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
BASE TRUSSES
VALLEY TRUSS TYPICAL
GABLE END, COMMON TRUSS
no I-- Toy —
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05 146 MPH
WIND DESIGN PER ASCE 7-10 160 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATEGORY II BUILDING
ATTACH 2x4 CONTINUOUS N0.2 SYP
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
1/"
TO THE ROOF W1 TWO USP WS45 4" X 4.5)
(
MAX TOP CHORD TOTAL LOAD = 50 PSF
WOOD SCREWS INTO EACH BASE TRUSS.
MAX SPACING = 24" O.C. (BASE AND VALLEY)
MINIMUM REDUCED DEAD LOAD OF 6 PSF
ON THE TRUSSES
�1.5" Max 46eQ'n NQQ �r,.
SERIAL'.
3B 9CA2 2100.00 00 004G 12'87 DF
FEBRUARY 14, 2012
=00
0 00
O 00
a
MiTek USA, Inc.
VALLEY TRUSS TYPICAL
SECURE VALLEY TRUSS
W/ ONE ROW OF t0d
NAILS 6" O.C. .
TRUSSED VALLEY SET DETAIL ST-VALLEY HIGH WIND
MITek USA, Inc. Page 1 of 1
GENERAL SPECIFICATIONS
GABLE END, COMMON TRUSS
OR GIRDER TRUSS
1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 3" WS3 USP OR EQUIVALENT
DO NOT USE DRYWALL OR DECKING TYPE SCREW
3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND
SECURE PER DETAIL A
4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING
EQUILIVANT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING.
6. NAILING DONE PER NDS - 01
7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
BASE TRUSSES
VALLEY TRUSS TYPICAL
GABLE END, COMMON TRUSS
nD n-IDIICD T01 fee
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05 146 MPH
WIND DESIGN PER ASCE 7-10 160 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6112
ATTACH 2x4 CONTINUOUS NO.2 SYP CATEGORY II BUILDING
TO THE ROOF W/ TWO USP WS3 (1/4" X 3") EXPOSURE C
WOOD SCREWS INTO EACH BASE TRUSS. WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
MAX SPACING = 24" O.C. (BASE AND VALLEY)
MINIMUM REDUCED DEAD LOAD OF 6 PSF
ON THE TRUSSES
DETAIL A
(NO SHEATHING)
N.T.S.
NOVEMBER 26, 2014 TRUSSED VALLEY SET DETAIL ST-VALLEY
(HIGH' WIND VELOCITY)
0 ot�
000
DOmn
MiTek USA, Inc.
NOTE: VALLEY STUD SPACING NOT
TO EXCEED 48" O.C. SPACING
ATTACH VALLEY TRUSSES TO
LOWER TRUSSES WITH
USP RT7 OR EQUIVALENT
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05 146 MPH
WIND DESIGN PER ASCE 7-10 160 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
CATEGORY II BUILDING
EXPOSURE B or C
WIND DURATION OF LOAD INCREASE: 1.6
MAX TOP.CHORD TOTAL LOAD = 50 PSF
MAX SPACING = 24" O.C. (BASE -AND VALLEY)
SUPPORTING TRUSSES DIRECTLY UNDER
VALLEY TRUSSES MUST BE DESIGNED
WITH A MAXIMUM UNBRACED LENGTH OF
2'-10" ON AFFECTED TOP CHORDS.
NOTES:
- SHEATHING APPLIED AFTER
INSTALLATION OF VALLEY TRUSSES
- THIS DETAIL IS NOT APPLICABLE FOR
SPF-S SPECIES LUMBER.
NON -BEVELED
BOTTOM CHORD
CLIP MUST BE APPLIED
TO THIS FACE WHEN
PITCH EXCEEDS 6/12.
(MAXIMUM 12/12 PITCH)
MiTek USA, Inc. Page 1 of 1
FOR BEVELED BOTTOM
CHORD, CLIP MAY BE
APPLIED TO EITHER FACE
CLIP MAY BE APPLIED
TO THIS FACE UP TO
A MAXIMUM 6/12 PITCH
u\
NON -BEVELED
BOTTOM CHORD
���ttt11F0011p�+'
► itlT :. �i i�i�
SERIAL •,#
. m BC A2 2100 00 00 g0.'4C 12 87,DF .
MAY 24, 2012
DO
a�aa
0 00
O OO
a
MiTek USA, Inc.
I DIAGONAL BRACE
Standard Gable End Detail
Typical 2x4 L-Brace Nailed To
2x4 Verticals W/10d Nails, 6" o.c.
Vertical Stud
SECTION B-B
TRUSS GEOMETRY AND CONDITIONS
SHOWN ARE FOR ILLUSTRATION ONLY.
12'
Varies to Common Truss
Vertical Stud
(4) - 16d Nails
(2) - 10d Nails into 2x6
SECTION A -A
ST-GE190-SP
MiTek USA, Inc. Page 1
2X6 SP OR SPF N.. 2
DIAGONAL BRACE
16d Nails
Spaced 6" o.c.
2X6 SP OR SPF No. 2
Typical Horizontal Brace
Nailed To 2x4 Verticals
w/(4)-10d Nails
OR SPF No. 2
SEE INDIVIDUAL MITEK ENGINEERING PROVIDE 2x4 BLOCKING BETWEEN THE FIRST
DRAWINGS FOR DESIGN CRITERIA TWO TRUSSES AS NOTED. TOENAIL BLOCKING
TO TRUSSES WITH (2) - 10d NAILS AT EACH END.
* ATTACH DIAGONAL BRACE TO BLOCKING WITH
B E B
3x4 = (5) - 10d NAILS.
(4) - 8d NAILS MINIMUM, PLYWOOD
SHEATHING TO 2x4 STD SPF BLOCK
Diagonal Bracing * * - L-Bracing Refer
Refer to Section A -A to Section B-B
24" Max
Roof Sheath
NOTE:
1. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS.
2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND
WALL TO BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT.
3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG.
1'-0"
ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT
Max.
BRACING OF ROOF SYSTEM.
4. "L" BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF or SP No.3
OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6" O.C.
5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF
DIAPHRAM AT 4'-0" O.C.
6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2x6 AND A
2x4 AS SHOWN WITH 16d NAILS SPACED 6" O.C. HORIZONTAL
BRACE TO BE LOCATED AT THE MIDSPAN OF THE LONGEST GABLE STUD.
ATTACH TO VERTICAL GABLE STUDS WITH (4) 10d NAILS THROUGH 20.
Ala Brace
(REFER TO SECTION A -A)
g•
7. GABLE STUD DEFLECTION MEETS OR EXCEEDS U240.
at 1/3 polntS
8. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES.
If needed
9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR
\�
TYPE TRUSSES.
10. 10d AND 16d NAILS ARE 0.131"X3.0" AND 0.131"X3.5" COMMON WIRE NAILS
RESPECTIVELY.
11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12
BY SPIB/ALSC.
End Wall
Minimum
Stud Size
Species
and Grade
Stud
Spacing
Without
Brace
2x4
L-Brace
DIAGONAL
BRACE
2 DIAGONAL
BRACES AT
1/3 POINTS
Maximum Stud Length
2x4 SP No. 3 / Stud
12" O.C.
3-8-10
5-6-11
6-6:11
11-1-13
2x4 SP No. 3,1 Stud
16" O.C.
3-3-10
4-9-12
6-6-11
9-10-15
2x4 SP-No.3/Stud
124" O.C.
2-8-6
3-11-3
5-4-12
8-1-2
2x4 SP No.2
12" O.C.
3-10-15
5-6-11
6-6-11
11-8-14
2x4 SP No. 2
16" O.C.
3-6-11
4-9-12
6-6-11
10-8-0
2x4 SP No.2
24" O.C.
1 3-1-4
1 3-11-3
1 6-2-9
1 9-3-13
Diagonal braces over 6'-3" require a 2x4 T-Brace attached to
one edge. Diagonal braces over 12'-6" require 2x4 I -braces
attached to both edges. Fasten T and I braces to narrow edge
of diagonal brace with 10d nails 61n o.c., with Sin minimum
end distance. Brace must cover 90 % of diagonal length.
T or I braces must be 2x4 SPF No. 2 or SP No. 2.
MAX MEAN ROOF HEIGHT = 30 FEET
EXPOSURE B or C
ASCE 7-10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND C
DURATION OF LOAD INCREASE: 1.60 CONNECTION OF BRACING IS BASED ON MWFRS.
p,..=17,
•�1
�;,•-
.
'64 .
/ X \
2x6 DIAGONAL BRACE SPACED
48" O.C. ATTACHED TO VERTICAL WITH
(4) -i6d NAILS, AND ATTACHED TO
BLOCKING WITH (5) -10d NAILS.
HORIZONTAL BRACE
(SEE SECTION A -A)
:�4{►!Itlo>iU�fQP�dd'
NO
3B.130A2214000.0U00461287DF:: i
`I
'r.
August 10, 2010 T-BRACE / I -BRACE DETAIL WITH 2X BRACE ONLY ST - T-BRACE 2
L � I�� O MiTek USA, Inc. Page 1 of 1
FV-INote: T-Bracing / I -Bracing to be used when continuous lateral bracing
0 0o is Impractical. T-Brace / I -Brace must cover 90% of web length.
L� Note: This detail NOT to be used to convert T-Brace / I -Brace
MiTek USA, Inc.
webs to continuous lateral braced webs.
Nailing Pattern
T-Brace size
Nail Size
Nail Spacing
2x4 or 2x6 or 2x8
10d
6" o.c.
Note: Nail along entire length of T-Brace / I -Brace
(On Two-Ply's Nail to Both Plies)
WE
Nails
-Brace
Nails
Brace Size
for One -Ply Truss
Specified Continuous
Rows of Lateral Bracing
Web Size
1
2
2x3 or 2x4
2x4 T-Brace
2x4 I -Brace
2x6
2x6 T-Brace
2x6 I -Brace
2x8
2x8 T-Brace
MI -Brace
Brace Size
for Two -Ply Truss
Specified Continuous
Rows of Lateral Bracing
Web Size
1
2
2x3 or 2x4
2x4 T-Brace
2x4 I -Brace
2x6
2x6 T-Brace
2x61-Brace
2x8
2x8 T-Brace
MI -Brace
T-Brace / I -Brace must be same species
and grade (or better) as web member.
g•. Nx�.4 ;.
SERI IAL ##
38 BC A2 2I 00.00 00 00.4C 12 $7. DF`
--'*''------------------------------- ...... . ... ................ ...� _...
FEBRUARY8,'2008 LATERAL BRACING RECOMMENDATIONS ST-STRGBCK
n�O ® MiTek USA, Inc. Page 1 of 1
TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS,
0 00 -
l� 2x6 "STRONGBACK" IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET
MiTek USA, Inc. ALONG A FLOOR TRUSS.
NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY
ABOVE THE BOTTOM CHORD. SECURELY FASTENED TO THE TRUSS USING ANY OF THE METHODS ILLUSTRATED BELOW.
NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE BOTTOM CHORD OF
THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO END, CONNECTED
WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS.
ATTACH TO VERTICAL ATTACH TO VERTICAL INSERT WOOD SCREW THROUGH OUTSIDE
USE METAL FRAMING WEB WITH (3) - 10d NAILS SCAB WITH (3) - 10d NAILS FACE OF CHORD INTO EDGE OF STRONGBACK
ANCHOR TO ATTACH (0.131"x 3") (0.131"x 3") (DO NOT USE DRYWALL TYPE SCREWS)
TO TOP CHORD
ATTACH TO VERTICAL
\ 1 / WEB WITH (3) - 10d NAILS
VERTICAL WEB IS
RECOMMENDED WHILE
OF TRUSS. FASTEN TO TOP AND
BOTTOM CHORD WITH (2) - 10d
ATTACH TO CHORD
WITH TWO #12 x 3"
WS (.216" DIAM.)
USE ME I AL 1-HAMINCi ATTACH TO VERTICAL AT I ACH 10 VEH i [CAL INSERT SCREW THROUGH OUTSIDE
ANCHOR TO ATTACH WWITH (3) 1 NAILS SCAB WITH (3) - 10d NAILS FACE OF CHORD INTO EDGE OF
WEB TO BOTTOM CHORD (0EB x 3") (0.131"x 3") STRONGBACK (DO NOT USE
DRYWALL TYPE SCREWS)
TRUSS 2x6
4-0-0 WALL BLOCKING
HERS B
STRONGBACK (TYPICAL SPLICE) (BY OT) ( Y OTHERS)
- e�y:Y�. :(a:,, ii�r �tc'' •„s4� :5` �_ `�' � u�Ll., e.�i••�•••••' :, G:ra.
tsi♦OfAlAa1�' I
THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO ADEQUATE SUPPORT,
DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4'-0" LONG I +� •"�0°+•�'
s +,• 10 go-`•G�
SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS ew •- i'a+i�■
(0.131" x 3") EQUALLY SPACED. :� •'' "'
ALTERNATE METHOD OF SPLICING:
OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4'-0" AND FASTEN WITH (12) - 10d
NAILS (0.131" x 3") STAGGERED AND EQUALLY SPACED.
(TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL) �" . �UA`
JANUARY 28, 2015 LATERAL TOE -NAIL DETAIL ST-TOENAIL SP
h+
00 ® �NOTES: MiTek USA, Inc. Page 1 of 1
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45 DEGREES WITH THE MEMBER
0 0o AND MUST HAVE FULL WOOD SUPPORT. (NAIL MUST BE DRIVEN THROUGH AND
0 0o EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
MiTek USA, Inc. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES
FOR MEMBERS OF DIFFERENT SPECIES. .
OE -NAIL SINGLE SHEAR VALUES PER NDS 2001 (lb/nail)
DIAM.
SP
DF
HF
SPF
SPF-S
�ry
131
88.0
80.6
69.9
68.4
59.7
p
.135
93.5
85.6
74.2
72.6
63.4
J
%
LO
162
108.8
99.6
86.4
84.5
73.8
ri
.128
74.2
67.9
58.9
57.6
50.3
z
j
.131
75.9
69.5
60.3
59.0
51.1
N
.148
81.4
74.5
64.6
1 63.2
52.5
vi
THIS DETAIL APPLICABLE TO THE
THREE END DETAILS SHOWN BELOW
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
SIDE VIEW
(2x3)
2 NAILS
NEAR SIDE
.VALUES SHOWN ARE CAPACITY PER TOE -NAIL. NEAR SIDE
APPLICABLE DURATION OF LOAD INCREASES MAYBE APPLIED.
EXAMPLE:
(3) - 16d NAILS (.162" diam. x 3.5') WITH SPF SPECIES BOTTOM CHORD
For load duration increase of 1.15: SIDE VIEW
3 (nails) X 84.5 (lb/nail) X 1.15 (DOL) = 291.5 lb Maximum Capacity (2x4)
3 NAILS
NEAR SIDE
NEAR SIDE
NEAR SIDE
ANGLE MAY
VARY FROM
30°TO 60"
45.00°
ANGLE MAY
VARY FROM
30 a TO 60 °
SIDE VIEW
(2x6)
4 NAILS
NEAR SIDE
NEARSIDE
NEAR SIDE
NEAR SIDE
ANGLE MAY
VARY FROM
30 ° TO 60 °
45.00 -4 45.000
Its
tfl 1,
March 4, 2013 UPLIFT TOE -NAIL DETAIL ST-TOENAIL UPLIFT
j \UO/ Iju011uOr
O 00
a
MiTek USA, Inc.
SIDE VIEW
NEAR SIDE
FAR SIDE
MiTek USA, Inc. Page 1 of 1
THIS DETAIL SHALL BE USED FOR A CONNECTION RESISTING
UPLIFT- FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE
FOR LOADS IN OTHER DIRECTIONS.
TOP PLATE
OF WALL
SIDE
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
TOE -NAIL WITHDRAWAL VALUES PER NDS 2005 (lb/nail)
DIAM.
I SP
DF
HF
SPF
SPF-S
C7
.131
59
46
32
30
20
p
.135
60
48
33
30
20
J
162
72
58
39
37
25
J
c
0
Z
.128
54
42
28
27
19
w
.131
55
43
29
28
19
J
J
in
Cl!
.148
62
48
34
31
21
Z
Cl)
.120
51
39
27
26
17
Z
O
.128
49
38
26
25
17
c
.131
51
39
27
26
17
m
.148
57
44
31
28
20
END VIEW
1" FOR
L / I X
1/ 1-3� 6" FOR 3I 55NAILIL
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES
WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE
NAIL FROM THE MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF
NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING
OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH
LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN
THE CONNECTION.
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. ti
EXAMPLE:
(3) - 16d NAILS (.162" diam. x 3.5") WITH SPF SPECIES TOP PLATE
For Wind DOL of 1.33:
3 (nails) X 37 (lb/nail) X 1.33 (DOL for wind) = 148 lb Maximum Allowable Uplift Reaction Due To Wind
For Wind DOL of 1.60:
3 (nails) X 37 (lb/nail) X 1.60 (DOL for wind) = 177 lb Maximum Allowable Uplift Reaction Due To Wind
If the uplift reaction specified on the Truss Design
Drawing exceeds 147 lbs (177 Ibs) Building Designer
is responsible to specifiy a different connection.
•.. USE (3) TOE -NAILS ON 2x4 BEARING WALL
•" USE (4) TOE -NAILS ON 2x6 BEARING WALL
bd8
$0083
d.''.�.? ..`r.;�..•...•• ,wee
' �j � i •brie ...'� .��::.'
`A ar -A'I'll-Tin nrirfiirin
i
FEBRUARY 5, 2016
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
1.0 X 14
TYP W NAILER ATTACHMENT I -2x2 NAILING
2x2 NAILER ATTACHMENT
GENERAL SPECIFICATIONS
MAX LOAD- 55 psf Roof Load, 170 mph, ASCE
7-10, 29'-0" Mean Height, Exp. B, C or D.
2 W Jul . ....... wo,"?r
0
4-Al
J10083-
I AN'
i4w- 4�
3130CAi2l
-'�✓
April 11, 2016 TYPICAL ALTERNATE BRACING DETAIL ST-FLAT GIR BRACE
FO EXTERIOR FLAT GIRDER TRUSS
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
12
VARIES
(4) 12d
TRUSS 24" o.c. (4) 12d
MAX 3011(2'-611)
UPLIFT CONNECTION
(SEE ROOF TRUSS) 2x6 #2 SP (Both Faces)
24 " o.c.
EXTERIOR FLAT SIMPSON H-5
GIRDER4p1pd�Qg*
y� ri'�..•:.�..�� , alp .
6008 fr rp
•
A.
313:6C A2 21 flO.QO 00 Q0 4C 12 87 DF
�•twuaws�,'raw.j'uitY"r117itetfsn�[e}.wmNBmlta6ertn'3}1114(1Lnt�lw�ei;i?YN'f`bic_Int�t,vgwwaiN.Nt o aaLmte(�+t1uM1r+3;cd6.L•nrri:Gd.M�tt4dn YAxtMk..o udcimx:r.ohli�ari.4 �h:
`•+ 1k•+t�hyA7rt&t fapidd, LifmtlavptgmupMpwi>- +d�+wtn. J1P�upe,n+nbn�.atnta4,wedage�astmp..ash,M'nrin dwu pttnitrpnlN?:e 1:0air.w,t tvel. igai�.ik,rdyb wr�wi Sd�NtM. .Anth nYT. TAtitb4111�p.E.
�e'7inghrajf �kgnfkllypuk'arAA7.sets+bin'iM�Nq,!fartal6m}Puyur,•wMiahUNa.9l;M.¢!atw�ItalY,gnYW11N D. P�iddt4�olMaf'ebwq�lmcex>esglswi+}r4np.wndkmMtratrrbdllew np.nLe;Y,. • V.u�lurrtsfate:nwvgMa, liYR.mraai+}n+ Ng149/MdlIRpeuMfenpt�ElT; mM,Wtn pMk3epnttdya,i.w,n.s[nUlIaNKA��GySdEnrtyltnu,nrttyo Mtf 6wWiftr3pe.suWe d�'. Arla9(lyae/nHk1yud�dN"v!eIht :sedpnsiwMR,eulNllilfBF!.w• twp4xfi`.5rtetai e�ecalseiiULwML k.tiOnip[S*s+wmt Gntwe4ena: 4.w ' 8008?.'
4udgiit. lu[IeB
d.
F. :3494G . `pfd Ad Reel GdiiiaAnlhonyl;iaa6rip4 P.L [epmdcilio'oa46isdaieneiU is ai�lemi, ii plo5�itid wdkmPeeriNea Oeimiision6csA•I kolL4tiii•,Wha961aa6bltlrlt•6..
OCTOBER 15, 2014 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS ST-REP01 Al
AND DAMAGED OR MISSING CHORD SPLICE PLATES
0 00
0 00
a
MiTek USA, Inc.
MiTek USA, Inc. Page 1 of 1
TOTAL NUMBER Of
NAILS EACH SIDE
OF BREAK
X
INCHES
MAXIMUM FORCE (Ibs)15% LOAD DURATION
SP
DF
SPF
HF
2x4
2x6
2x4
2x6
2x4
2x6
2x4
2x6
2x4
2x6
20
30
24"
1706
2559
1561
2342
1320
1980
1352
2028
26
39
30"
2194
3291
2007
3011
1697
2546
1738
2608
32
1 48
36"
2681
4022
2454
3681
2074
3111
2125
3187
38
57
42"
3169
4754
2900
4350
2451
3677
2511
3767
44
66
48"
3657
5485
3346
5019
2829
4243
2898
4347
DIVIDE EQUALLY FRONT AND BACK
ATTACH 2x SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH
FACE OF THE TRUSS (CENTER ON BREAK OR SPLICE) WITH 10d NAILS
(TWO ROWS FOR 2x4, THREE ROWS FOR 2x6) SPACED 4" O.C. AS SHOWN.(.131"dia. x 3")
STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 0-2-0 O.C.
SPACING IN THE MAIN MEMBER. USE A MIN. 0-3-0 MEMBER END DISTANCE.
THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12". (C=PLATE LENGTH FOR SPLICE REPAIRS)
THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS:
L=(2)X+C
• 10d NAILS NEAR SIDE
+10d NAILS FAR SIDE
TRUSS CONFIGURATION
AND BREAK LOCATIONS
FOR ILLUSTRATIONS ONLY
THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO THE REQUIRED-X DIMENSION FROM ANY
PERIMETER BREAK OR HEEL JOINT AND A MINIMUM OF 6" FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE)
DO NOT USE REPAIR FOR JOINT SPLICES
NOTES:
1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES
NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS
SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED
REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED.
2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLING REPAIR
AND HELD IN PLACE DURING APPLICATION OF REPAIR.
3. THE END DISTANCE; EDGE DISTANCE AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID
UNUSUAL SPLITTING OF THE WOOD.
4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID
LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR'SPLICES.
5. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2x_ ORIENTATION ONLY.
6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS.
udra�� .rinnnnn.nn* A&lv
r------------
1
I:
March 4, 2013 SCAB APPLIED OVERHANGS
=00 O TRUSS CRITERIA:
LOADING: 40-10-0-10
0 0o DURATION FACTOR: 1.15
0 0o SPACING: 24" O.C.
TOP CHORD: 2x4 OR 2x6
PITCH: 4/12 - 12/12
MiTek USA, Inc. HEEL HEIGHT: STANDARD HEEL UP TO 12" ENERGY HEEL
END BEARING CONDITION
NOTES:
1. ATTACH 2x_ SCAB (MINIMUM NO.2 GRADE SPF, HF, SP, DF) TO ONE FACE OF
TRUSS WITH TWO ROWS OF 10d COMMON WIRE NAILS (.148"DIA. x 3") SPACED
6" O.C.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED
TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
NOTE: TRUSS BUILT WITHOUT AN OVERHANG.
THIS DETAIL IS NOT TO BE USED WHEN
OVERHANG HAS BEEN BROKEN OFF.
IMPORTANT
This detail to be used only with trusses (spans less than 40') spaced
24" oz. maximum and having pitches between 4/12 and 12/12 and
total top chord .loads not exceeding 50 psf.
Trusses not fitting these criteria should be examined individually.
REFVIDUAL TRUSS DESIGN
FOR EPLATE SIIZR TO IES AND LUMBER GRADES
ST-REP13A
MiTek USA, Inc. Page 1 of 1
*� V N
'-SOE
REPAIR REQUESTS
When sending in repair requests, please use engineering sheets to describe issue or damage, and email to design@altruss.com.
NOTE: It is appreciated if actual pictures of the damage or problem are included with the engineering sheet, but pictures by themselves are usually not very
helpful. Engineering sheets with the damage or issue noted are required.
1. If there are any special circumstances (sheeted, trades in, etc.) please make sure you note it on the drawing or email request.
2. We cannot provide sealed drawings for "field built" trusses.
2. See details below.
BREAKS: Use a line to note
the enact location of the break • . l
x3 11
1
22
21
1.5k4 11
3x6—.
ALT1 MOVED BEARING CONDITIOhI: L
USS Ii1ODIFICATI( N'
f�7lS8II !t74P=tRGEQELATES;
Liar,=in n� :=bxaLon of bearino; anrJ s too long t sion, tr; and be
provide dimension as needed + i�de plate that needs 'ed as oossible,and provider�iens ,ns as needed.
x3. FP= 3x3 11 3x4 1 5x4 11 1.5x4 11 5z6 =
3 4 6 7 8 10 11 12
'20 19 �_ _ 1 B 17 16 15 14 - j /12"
1.5X4 11 1.5x4 II. i q x1i6 = 3x6 FP= '3x4 = 3x3 = 4x6 - TOO LONG
12.
MISSiNGPIECE: ifthereare
gjultiple breaks; resulting in a
sectidri: missing
3x6
5x4:. 4
3
'filEr'glBER SPLIT:
'Denote exact 1&a6gn of splitand
pro.=ide- an apprcaxirnate length.
3x4
5
BREAKS: Use a line to note
the e;;act location of the break
3x4 MISSING 1 DAMAGED PLATES:
7 Gi rcle plate .hat needs addressed.
3x ,.