HomeMy WebLinkAboutRevision 4-19-22OFFICE USE ONLY:
DATE FILED:
REVISION FEE:
LOCATION/SITE
ADDRESS:
6013 Spruce Dr, Fort Pierce
PER1MT # SLC 2108-0440
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982.5652
(772) 462-1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Energy Calcs change for windows and insulation
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: C13C1263609
BUSINESS NAME: Associated Homes Inc
QUALIFIERS NAME: Bob Aubry
ADDRESS: 10380 SW Village Center Dr #179
CITY: Port St Lucie STATE: FI
PHONE (DAYTIME): 772-528-2202
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME:
STATE:
ARCHITECT/ENGINEER INFORMATION:
NAME: Summit Design and Forensics
ADDRESS: 725 SE Port St Lucie Blvd #203
CITY: Port St Lucie
PHONE (DAYTIME): 772-589-0712
SLCCC: 9123109
Revised 06130117
STATE: FI
ST. LUCIE CO CERT. #:
FAX:
ff"V IS
FAX:
ZIP: 34987
ZIP:
ZIP: 34984
FILECOPY
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: DOTY AND BROWN RESIDENCE
BuilderName: ASSOCIATED HOMES, INC.
Street: 6013 SPRUCE DRIVE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
PermitNumber:
Owner: JAMES DOTY AND RILEY BROWN
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
1.0. Wall Typeg2Q54.6- sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block. - Polystyrene Bead AggreR=0.0 1828.20 ft2
b. Frame - Wood, Adjacent
R=11.0 226.33 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2190.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2190.00 ft2
6. Conditioned floor area above grade (W) 2190
b. N/A
R= ft2
Conditioned floor area below grade (W) 0
c. N/A
R= ft2
7. Windows(210.3 sgft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
R ft2
6 150
'a: "(7-Factor: Sgl, U=0.55 210.30 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
35.2 SEER:16.00
c. U-Factor; N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.250
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): WA
a. Electric
Cap: 40 gallons
9. FioorTypes (2190.0 sgft.) Insulation Area
EF:0.980
a. Slab -On -Grade Edge Insulation R=0.0 2190.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
1 a Credits
None
Total Proposed Modified Loads: 64.57
Glass/Floor Area: 0.096
PASS
Total Baseline Loads: 66.61
I hereby certify that the plans and specifications covered by
Review of the plans and
ST,gTt�
this calculation are in compliance with the Florida Energy
Code.
specifications covered by this
calculation indicates compliance
OiVE
, _ = O
PREPAR D Y:
with the Florida Energy Code.
Before construction is completed
DATE: 202
this building will be inspected for
compliance with Section 553.908
+)� d
*
I hereby certify that this building, as designed, is ' mpliance
Florida Statutes.,
,
6�
with the Florida Energy Cod
CODWME 1¢�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Proposed On of 0.080 exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405
.2.3
4/19/2022 10:29 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Softw FILE
®� 1 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
DOTY AND BROWN RESIDE
Bedrooms:
4
Address Type:
StreetAddress
BuildingType:
User
ConditionedArea:
2190
Lot#
OwnerName:
JAMES.DOTY AND RILEY BR
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
ASSOCIATED HOMES, INC.
RotateAngle:
0
Street:
6013 SPRUCE DRIVE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
FamilyType:
Detached
FL,
New/Existing:
New (From Plans)
Comment:
SEDONA VISTA 4/3- GARAGE LEFT
CLIMATE.
/
Design Temp
Int Design Temp
Heating
Design DailyTemp
V/ DesignLocation
TMY Site
97.5 %
2.5 %
Winter
Summer DegreeDays Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62,
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2190
19949
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfiIID
Finished Cooled
Heated
1
MASTER BEDROO
218
1983.8 No
0
1
1
Yes
Yes
Yes
2
WIC 1
32
259.2 No
0
1
Yes
Yes
Yes
3
WIC 2
36
291.6 No
0
1
No
Yes
Yes
4
MASTER BATH
174
1409.4 No
0
1
Yes
Yes
Yes
5
DEN
151
1525.1 No
0
1
Yes
Yes
Yes
6
FOYER
104
1050.4 No
0
1
Yes
Yes
Yes
7
DINING ROOM
143
1444.3 No
0
1
Yes
Yes
Yes
8
FAMILY ROOM
320
3232 No
0
1
Yes
Yes
Yes
9
KITCHEN
190
1919 Yes
0
1
No
Yes
Yes
10
NOOK
88
888.8 No
0
1
Yes
Yes
Yes
11
BEDROOM 2
139
1125.9 No
0
1
1
Yes
Yes
Yes
12
CLST 2
16
129.6 No
0
1
No
Yes
Yes
13
CLST 3
18
145.8 No s
0
1
Yes
Yes
Yes
14
LAUNDRY
66
534.6 No
.0
1
No
Yes
Yes
15
HALLWAY
65
526.5 No
0
1
No
Yes
Yes
16
M. TOILET
32
259.2 No
0
1
Yes
Yes
Yes
17
CLST 4
18
145.8 No
0
1
No
Yes
Yes
18
BEDROOM 4
129
1044.9 No
0
1
1
Yes
Yes
Yes
19
BATH 3
66
534.6 No
0
1
Yes
Yes
Yes
20
BEDROOM 3
137
1109.7 No
0
1
1
Yes
Yes
Yes
21
BATH
48
388.8 No
0
1
Yes
Yes
Yes
4/19/202210:29 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# FloorType
Space
Perimeter PerimeterR-Value
Area
Joist R-Value
Tile Wood Carpet
ISlab-On-Grade Edge Insulation
MASTERBEDRO
39ft
0
218W2
_-_-
0
1
0
r
2Slab-On-Grade Edge Insulation
WIC 1
8ft
0
321`12
---_
0
1
0
3Slab-On-Grade Edge Insulation
WIC 2
1 ft
0
36ft2
____
0
1
0
4Slab-On-Grade Edge Insulation
MASTER BATH
22ft
0
174ft2
----
0
1
0
5Slab-On-Grade Edge Insulation
DEN
15ft
0
151ft2
_---
0
1
0
6Slab-On-Grade Edge Insulation
FOYER
8ft
0
104ft2
____
0
1
0
7Slab-On-Grade Edge Insulation
DINING ROOM
11 ft
0
143ft2
____
0
1
0
8Slab-On-Grade Edge Insulation
FAMILY ROOM
16ft
0
320ft2
___-
0
1
0
9Slab-On-Grade Edge Insulation
KITCHEN
i ft
0
190ft2
--__
0
1
0
10SIab-On-Grade Edge Insulation
NOOK
8 ft
0
88 ft2 .
__._
0
1
0
11Slab-On-Grade Edge Insulation
BEDROOM2
'19.9ft
0
139ft2
___-
0
1
0
12SIab-On-Grade Edge Insulation
CLST 2
1 ft
0
16 ft2
_--_
0
1
0
13SIab-On-Grade Edge Insulation
CLST 3
2 ft
0
18 ft2
__-_
0
1
0
14SIab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
66ft2
---_
0
1
0
15SIab-On-Grade Edge Insulation
HALLWAY
i ft
0
65ft2
----
0
1
0
16Siab-On-Grade Edge Insulation
M.TOILET
12ft
0
32ft2
____
0
1
0
17SIab-On-Grade Edge Insulation
CLST 4
i ft
0
18 ft2
_-__
0
1
0
18SIab-On-Grade Edge Insulation
BEDROOM
11 ft
0
129ft2
____
0
1
0
19SIab-On-Grade Edge insulation
BATH 3
6 ft
0
66 ft2
___-
0
1
0
20SIab-On-Grade Edge Insulation
BEDROOM
24ft
0
137ft2
--__
0
1
0
21SIab-On-GradeEdgeinsulation
BATH
5 ft
0
48 ft2
_--_
0
1
0
ROOF
V
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
# Type Materials Area
Area . Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip Composition shingles 2449 ft2
0 ft2 Medium
N
0.1 No 0.9
No
0
26.57
ATTIC
# Type
Ventilation
Vent Ratio (1 in)
Area
FIBS IRCC
1 Full attic
Vented
300 2190 ft2
N N
4/19/2022 10:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
CeilingType Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) MASTER BEDRO
30
Blown
218ft2
0.1
Wood
2
Under Attic (Vented) WIC 1
30
Blown
32ft2
0.1
Wood
3
Under Attic (Vented) WIC 2
30
Blown
36ft2
0.1
Wood
4
Under Attic (Vented) MASTER BATH
30
Blown
174 ft2
0.1
Wood
5
Under Attic (Vented) DEN
30
Blown
151 ft2
0.1
Wood
6
Under Attic (Vented) FOYER
30
Blown
104 ft2
0.1
Wood
7
Under Attic (Vented) DINING ROOM
30
Blown
143 ft2
0.1
Wood
8
Under Attic (Vented) FAMILY ROOM
30
Blown
320ft2
0.1
Wood
9
Under Attic (Vented) KITCHEN
30
Blown
190ft2
0.1
Wood
10
Under Attic (Vented) NOOK
30
Blown
88 ft2
0.1
Wood
11
Under Attic (Vented) BEDROOM 2
30
Blown
139 ft2
0.1
Wood
12
Under Attic (Vented) CLST 2
30
Blown
16 ft2
0.1
Wood
13
Under Attic (Vented) CLST 3
30
Blown
18 ft2
0.1
Wood
14
Under Attic (Vented) LAUNDRY
30
Blown
66ft2
0.1
Wood
15
Under Attic (Vented) HALLWAY
30
Blown
65 ft2
0.1
Wood
16
Under Attic (Vented) M.TOILET
30
Blown
32ft2
0.1
Wood
17
Under Attic (Vented) CLST 4
30
Blown
18 ft2
0.1
Wood
18
Under Attic (Vented) BEDROOM 4
30
Blown
129 ft2
0.1
Wood
19
Under Attic (Vented) BATH 3
30
Blown
66 ft2
0.1
Wood
20
Under Attic (Vented) BEDROOM
30
Blown
137ft2
0.1.
Wood
21
Under Attic (Vented) BATH
30
Blown
48 ft2
0.1
Wood
WALLS
Omt
Adjacent Space Cavity
TO Wall Twe
Width
Height
Sheathing Framing Solar
Below
_ 1
S
_Va
Exterior Concrete Block-PolystyrMASTER BE
0
9
0 9
1
81.8ft2
0
0
0.1
0
_ 2
W
Exterior Concrete Block-PolystyrMASTER BE
0
13
0 9
1
118.1 ft2
0
0
0.1
0
3
N
Exterior Concrete Block-PolystyrVMTER BE
0
17
0 9
1
154.4ft2
0
0
0.1
0
4
N
Exterior Concrete Block-Polystyrend/VIC 1
0
8
0 8
1
64.7 ft2
0
0
0.1
0
5
E
Exterior Concrete Block -PolystyNIASTER BA
0
8
0 8
1
64.7ft2
0
0
0.1
0
6
N
Exterior Concrete Block -PolystydAMTER BA
0
14
0 6
1
113.2ft2
0
0
0.1
0
7
E
Exterior Concrete Block- Polystyrene DEN
0
12
0 10
1
121.0 ft2
0
0
0.1
0
8
N
Exterior Concrete Block -Polystyrene DEN
0
3
0 10
1
30.3ft2
0
0
0.1
0
_ 9
E
Exterior Concrete Block -Polystyren60YER
0
8
0 10
1
80.7 ft2
0
0
0.1 _
0
_10
E
Exterior Concrete Block-PolystyQINNG ROO
0
11
0 10
1
110.9ft2
0
0
0.1
0
_ 11
W
Exterior Concrete Block -Polystyi"MILY ROO
0
16
0 10
1
161.3 ft2
0
0
0.1
0
12
W
Exterior Concrete Block- Polystyren(NOOK
0
8
0 10
1
80.7ft2
0
0
0.1
0
13
W
Exterior Concrete Block- PolystyffiEVROOM2
0
11
0 8
1
88.9ft2
0
0
0.1
0
_ 14
N
Exterior Concrete Block -Polystyi®EOROOM 2
0
9
0 8
1
72.8 ft2
0,
0
0.1
0
15
W
Exterior Concrete Block- PolystyrenGLST 3
0
2
0 8
1
16.2 ft2
0
0
0.1
0
_16
E
Exterior Concrete Block- PolystyrddeTOiLET
0
8
0 8
1
64.7ft2
0
0
0.1
0
_ 17
N
Exterior Concrete Block-PolystyrddeTOILEr
0
4
0 8
1
32.3 ft2'
0
0
0.1
0
_ 18
S
Exterior Concrete Block -Polystyd§Er )ROOM 4
0
11
0 8
1
88.9 ft2
0
0
0.1
0
_ 19
S
Exterior Concrete Block -PolystyrenSATH 3
0
6
0 8
1
48.5 ft2
0
0
0.1
0
4/19/2022 10:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
ype
Space Cavity Width
R-Value Et In El
Height
In
Area
Sheathing Framing Solar
B-Val-le Erection Ahsor
Below
GrarleO
_20 S
Exterior
Concrete Block- Polystyi%EVR00M 3. 0 13 0 8
1
105.1 ft2
0
0 0.1
0
_21 W
Exterior
Concrete Block -PolystyiBErDROOM3 0 11 0 8
1
88.9ft2
0
0 0.1
0
_22 S
Exterior
Concrete Block -PolystyreneBATH 0 5 0 8
1
40.4IF
0
0 0.1
0
_ 23 E
Garage
Frame - Wood
LAUNDRY 11 21 8
1
169.8 ft2
0
0.1 0.1
0
_ 24 S
Garage
Frame - Wood
DINING ROO 11 7 8
1
56.6 ft2
0
0.1 0.1
0
WINDOWS
Orientation shown istheentered, Proposed orientation.
Wall
Overhang
v #
Omt ID
Frame Panes
NFRC U-Factor SHGC Imp
Area
Depth
Separation
IntShade
Screening
1
W 2
Metal Low-ESingle
Yes 0.55 0.25 N
20.0 ft2
1 ft 0 in
1 It 4 in
None
None
2
N 3
Metal Low-ESingle
Yes 0.55 0.25 N
12.0 ft2
1 ft 0 in
1 ft 4 in
None
None
3
N 6
Metal Low-ESingle
Yes 0.55 0.25 N
12.0 ft2
1 ft 0 in
1 ft 4 in
None
None
4
E 7
Metal Low-ESingle
Yes 0.55 0.25 N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
5
E 10
Metal Low-ESingle
Yes 0.55 0.25 N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
6
W 11
Metal Low-ESingle
Yes 0.55 0.25 N
60.3 ft2
1 ft 0 in
1 ft 4 In
None
None
7
W 12
Metal Low-ESingle
Yes 0.55 0.25 N
15.0 ft2
1 It 0 in
1 ft 4 in
None
None
8
W 13
Metal Low-ESingle
Yes 0.55 0.25 N
15.0 ft2
1 It 0 in
1 ft 4 in
None
None
9
E 16
Metal Low-ESingle
Yes 0.55 0.25 N
4.0 ft2
1 It 0 in
1 It 4 in
None
None
10
S 18
Metal Low-ESingle
Yes 0.55 0.25 N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
11
S 19
Metal Low-ESingle
Yes 0.55 0.25 N
6.0 112
1 ft 0 in
1 ft 4 in
None
None
12
W 21
Metal Low-ESingle
Yes 0.55 0.25 N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
13
S 22
Metal Low-ESingle
Yes 0.55 0.25 N
6.0 ft2
1 ft 0 in
1 ft 4 in
None
None
GARAGE
#
FloorArea Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
441 ft2 441 ft2 28 It
8 ft
11
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse ProposedACH(50)
.000405 2327,4 127.69 239.72
.1331
7
HEATING SYSTEM
#
SystemType
Subtype Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None COP:1
27 kBtu/hr
1
sys#1
4/19/2022 10:29 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 Central Unit/
Split
Single SEER:16
35.2 kBtu/hr 1056 cfm 0.8 1
sys#1
HOT WATER SYSTEM
# SystemType
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.98 40 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # CompanyName
System Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
---- Supply ----
V
---- Return ---
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area LeakageType
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 150 ft2
Attic
15 ft2 Proposed Qn
LAUNDRY
--- cfm
175.2 cfm . 0.08 0.50
1 1
TEMPERATURES
ProgramableThermostat: N
Ceiling Fans:
Cooling[ j Jan [[ ]] Feb
Heatin[X] Jan [X) Feb
Mar
Mar
[ j Apr
[ ] Apr
[[ ] May rj Jun JXJ Jul
[ ] May [ j Jun Jul
AuJ
rj Au
X] Se
Sep
[ Oct Nov
Oct
Dec
Dec
H
Ventin [ TJan [[ ]jFeb
X Mar
[X] A r
C j Ma [ j Jun Jul
Aug
[ J Se
XNov
[Xl Oct X Nov
Dec
ThermostatSchedule: HERS 2006
Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9 10 11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80 80 80
80
PM
80
80 80
80 78 78
78
78
78 78 78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
80 80 80
80
PM
80
80 80
80 78 78
78
78
78 78 78
78
Heating (WD) AM
65
65 65
65 65 65
65
68
68 68 68
68
PM
68
68 68
68 68 68
68
68
68 68 68
68
Heating (WEH) AM
65
65 65
65 65 65
65
68
68 68 68
68
PM
68
68 68
68 68 68
68
68
68 68 68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8lbs/sq.ft.
0 ft2
Oft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(81bs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(81bs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(B Ibs/sq.ft.
ft2
ft
0.3
HALL 2ND FLR
Default(8lbs/sq.ft.
ft2
ft
0.3
M BATH
Defauit(8lbs/sq.ft.
ft2
ft
0.3
AHU CLST
Default(8lbs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
. 0.3
LAUNDRY
Default(8lbs/sq.ft.
ft2
ft
0.3
STAIRS 2ND FLR
4/19/2022 10:29 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8lbs/sq.ft.
ft2
ft
0.3
1 ST FLR HALL
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN/DINING
Default(8lbs/sq.ft.
ft2
ft
0.3
GREAT RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STORAGE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
PANTRY
Default 81bs/s .ft.
ft2
ft
0.3
POWDER RM
4/19/2022 10:29 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
ProjectName: DOTY AND BROWN RESIDENCE BuilderName: ASSOCIATED HOMES, INC.
Street: 6013 SPRUCE DRIVE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
U
Owner: JAMES DOTY AND RILEY BROWN Jurisdiction: ST LUCIE COUNTY
s
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air-permeableinsulationshall
requirements
The exteriorthermai envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
Insulation and any gaps in the air barrier shall be sealed'.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exteriorthermai envelope insulation forframed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
Thespace between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floorframing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, orfloorframing cavity insulation shall
andcantileveredfloors)
be permitted to be in contact with the top side of
sheathing, orcontinuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarderwith overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
orunconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrowcavities •
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garageseparation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be.cut neatly to fit around wiring an
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
behindextend i d wirina,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exteriorwalls adjacent to showers and tubs shall be
onexteriorwall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phoneboxon
The air barrier shall be installed behind electrical or communication
exteriorwalls
boxes orair-sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub -floor, wall covering or ceiling
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover I to nd walls orceilings.
a. in aaamon, inspection of iog waus snau De in accordance wnn the provisions of IGc-4uu.
4/19/2022 10:30 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Sgl, U=0.55
SHGC: SHGC=0.25
b. U-Factor: N/A
SHGC:
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
6013 SPRUCE DRIVE, FORT PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block- Polystyrene Bead AggreR=0.0
1828.20 ft2
b. Frame - Wood, Adjacent
R=11.0
226.33 ft2
1
c. N/A
R=
ft2
4
d. N/A
R=
ft2
11. Ceiling Type and insulation level
Insulation
Area
No
a. Under Attic (Vented)
R=30.0
2190.00 ft2
2190
b. N/A
R=
ft2
Area
c. N/A
R=
ft2
210.30 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
6 150
ft2
13. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
35.2
SEER:16.00
ft2
1.000 ft.
0.250
Area
ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 2190.00 ft2
b. N/A R= ft2
c. N/A R= ft2
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code co nt features. ' J
Builder Signature: Date:
Address of New Home: �p13 Q� Ciitty//Fl- Zip:
kBtu/hr Efficiency
27.0 COP:1.00
Cap: 40 gallons
EF: 0.98
None
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/19/2022 10:29 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1