HomeMy WebLinkAboutrevised electrical plan Ravinia 3A Left permit # 2202-03894Py 9
FORM R405-2020 Perm zD?7
• FLORIDA ENERGY EFFICIENCY CODEt e PUILDING CONSTRUCTION
C4U 'ne
Florida Department of Business and Professional RegulatiM. -residential Performance Method
Project Name: Ravina 3A
Builder Name:
Street: Garage Left
Permit Office:
City, State, Zip: Port St. Lucie, FL ,
Permit Number:
Owner. Ravinia 3A - Left Hand Garage
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type41328.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1168.00 ft2
b, Frame - Wood, Adjacent
R=13.0 160.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
11. Ceiling Types (1450.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1450.00 ft2
6. Conditioned floor area above grade (ft2) 1450
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(126.0 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Foyer, AH: Foyer
R ft2
6 75
a. U-Factor: Sgl, U=0.39 126.00 ft2
SHGC: SHGC=0.29
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
28.6 SEER:14.50
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 1.417 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.290
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1450.0 sqft.) Insulation Area
EF: 0.960
a. Slab -On -Grade Edge Insulation R=0.0 1450.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
CF
Glass/Floor Area: 0.087 Total Proposed Modified Loads: 45.06
PASS
Total Baseline Loads: 46.17
I hereby certify that the plans and specifications covered by
Review of the plans and
SHE ST
this calculation are in compliance with the Florida Energy
Code.
specifications covered by this
calculation indicates compliance
the Florida Energy Code.
ti,�,�' �• ' ,: ```;��O�;w`
�
PREPARED BY:
with
Before construction is completed
{ .
- ?t_ �i
DATE: 4-6-2022
this building will be inspected for
- j 4
compliance with Section 563.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
vr�, ter;��F,✓
with the Florida Energy Code.
01) wr- T ;
OWNER/AGENT:�� -
BUILDING OFFICIAL:
DATE: y -U -7 2
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
- Proposed Qn of 0.080 exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405
.2.3
4/5/2022 9:42 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INYU I SUMMAKY L;H1=UtXL1J I KCF'UK I
PROJECT
Title: Ravina 3A
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1450
Lot #
Owner Name: Ravinia 3A - Left Hand Garag Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name:
Rotate Angle: 180
Street:
Garage Left
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
Port St. Lucie,
Family Type: Detached
FL ,
New/Existing: New (From Plans) ,
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating Design Daily
Temp
v Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1450 11600
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 M Bedroom
195 1560 No
2
1
1
Yes
Yes
Yes
2 M WIC
48 384 No
0
1
No
Yes
Yes
3 M Bath
84 672 No
1
1
Yes
Yes
Yes
4 Bedroom 3
143 1144 No
1
1
1
Yes
Yes
Yes
5 Bath 2
54 432 No
0
1
Yes
Yes
Yes
6 Bedroom 2
143 1144 No
1
1
1
Yes
Yes
Yes
7 Great Room
232 1856 No
2
1
Yes
Yes
Yes
8 Dining
128 1024 No .2
1
Yes
Yes
Yes
9 Kitchen
202 1616 Yes
2
1
Yes
Yes
Yes
10 Foyer
85 680 No
1
1
Yes
Yes
Yes
11 Hall
35 280 No
0
1
No
Yes
Yes
12 Laundry
77 616 No
0
1
Yes
Yes
Yes
13 Hall
24 192 No
0
1
No
Yes
Yes
5 FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
M Bedroom 32 ft
195 ft2
_---
1 0
0
2 Slab -On -Grade Edge Insulatio
M WIC 1 ft
48 ft2
----
1 0
0
3 Slab -On -Grade Edge Insulatio
M Bath 6 ft
84 ft2
----
1 0
0
4 Slab -On -Grade Edge Insulatio
Bedroom 3 11 ft
143 ft2
----
1 0
0
4/5/2022 9:42 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
Fnpm Rangy -gran INPUT Sl1MMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulatio
Bath 2 6 ft
54 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulatio
Bedroom 2 11 ft
143 ft2
____
1
0
0
7 Slab -On -Grade Edge Insulatio
Great Room 30 ft
232 ft2
----
1
0
0
8 Slab -On -Grade Edge Insulatio
Dining 8 ft
128 ft2
____
1
0
0
9 Slab -On -Grade Edge Insulatio
Kitchen 12 ft
202 ft2
____
1
0
0
10SIab-On-Grade Edge Insulatio
Foyer 19 ft
85 ft2
----
1
0
0
11SIab-On-Grade Edge Insulatio
Hall 1 1 ft
35 ft2
_---
1
0
0
12SIab-On-Grade Edge Insulatio
Laundry 11 ft
77 ft2
---_
1
0
10
13SIab-On-Grade Edge Insulatio
Hall 2 1 ft
24 ft2
____
1
0
0
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Composition shingles 1571 ft2
0 ft2
Medium
N
0.6
No 0.9
No 0
22.62
ATTIC
IRCC
V # Type
Ventilation Vent Ratio (1 in)
Area
RBS
1 Full attic
Vented
150
1450 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
M Bedroom
30
Batt
195 ft2
0.1
Wood
2 Under Attic (Vented)
M WIC
30
Batt
48 ft2
0.1
Wood
3 Under Attic (Vented)
M Bath
30
Batt
84 ft2
0.1
Wood
4 Under Attic (Vented)
Bedroom 3
30
Batt
143 ft2
0.1
Wood
5 Under Attic (Vented)
Bath 2
30
Batt
54 ft2
0.1
Wood
6 Under Attic (Vented)
Bedroom 2
30
Batt
143 ft2
0.1
Wood
7 Under Attic (Vented)
Great Room
30
Batt
232 ft2
0.1
Wood
8 Under Attic (Vented)
Dining
30
Batt
128 ft2
0.1
Wood
9 Under Attic (Vented)
Kitchen
30
Batt
202 ft2
0.1
Wood
10 Under Attic (Vented)
Foyer
30
Batt
85 ft2
0.1
Wood
11 Under Attic (Vented)
Hall 1
30
Batt
35 ft2
0.1
Wood
12 Under Attic (Vented)
Laundry
30
Batt
77 ft2
0.1
Wood
13 Under Attic (Vented)
Hall 2
30
Batt
24 ft2
0.1
Wood
4/5/2022 9:42 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FnR&A Ran.x;_gngn INPHT .RHMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
To
Space
XA/M11ype
1
N=>S
Exterior
Concrete Block - Int InsuM Bedroom
4.1
14
0
8 0
112.0 ft2
0
0
0.4
0
2
W=>E
Exterior
Concrete Block - Int InsuM Bedroom
4.1
18
0
8 0
144.0 ft2
0
0
0.4
0
3
W=>E
Exterior
Concrete Block - Int Insul M Bath
4.1
6
0
8 0
48.0 ft2
0
0
0.4
0
4
W=>E
Exterior
Concrete Block - Int InsuBedroom 3
4.1
11
0
8 0
88.0 ft2
0
0
0.4
0
5
W=>E
Exterior
Concrete Block - Int Insul Bath 2
4.1
6
0
8 0
48.0 ft2
0
0
0.4
0
6
W=>E
Exterior
Concrete Block - Int InsuBedroom 2
4.1
11
0
8 0
88.0 ft2
0
0
0.4
0
7
N=>S
Exterior
Concrete Block - Int Inst(Breat Room
4.1
16
0
8 0
128.0 ft2
0
0
0.4
0
8
E=>W
Exterior
Concrete Block - Int InsdDreat Room
4.1
14
0
8 0
112.0 ft2
0
0
0.4
0
9
E=>W
Exterior
Concrete Block - Int Insul Dining
4.1
8
0
8 0
64.0 ft2
0
0
0.4
0
10
E=>W
Exterior
Concrete Block - Int Insul Kitchen
4.1
12
0
8 0
96.0 ft2
0
0
0.4
0
11
E=>W
Exterior
Concrete Block - Int Insul Foyer
4.1
8
0
8 0
64.0 ft2
0
0
0.4
0
12
S=>N
Exterior
Concrete Block - Int Insul Foyer
4.1
10
0
8 0
80.0 ft2
0
0
0.4
0
_ 13
W=>E
Exterior
Concrete Block - Int Insul Foyer
4.1
1
0
8 0
8.0 ft2
0
0
0.4
0
14
E=>W
Exterior
Concrete Block - Int Insul Laundry
4.1
11
0
8 0
88.0 ft2
0
0
0.4
0
_ 15
N=>S
Garage
Frame - Wood Laundry
13
7
8
56.0 ft2
0.23
0.4
0
16
N=>S
Garage
Frame - Wood Bedroom 2
13
13
8
104.0 ft2
0.23
0.4
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S=>N
Insulated Foyer
None
.39
3
6 10
20.5 ft2
2
N=>S
Insulated Laundry
None
.39
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered orientation => chan ed-to Worst Case.
V
Wall
Overhang
# Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 N=>S 1
Vinyl Low-E Single Yes
0.39
0.29
Y
20.0 ft2
1 ft 5 in
1 ft 4 in
None
None
2 W=>E 4
Vinyl Low-E Single Yes
0.39
0.29
Y
15.0 ft2
1 ft 5 in
1 ft 4 in
None
None
3 W=>E 6
Vinyl Low-E Single Yes
0.39
0.29
Y
15.0 ft2
1 ft 5 in
1 ft 4 in
None
None
4 N=>S
7
Vinyl Low-E Single Yes
0.39
0.29
Y
41.0 ft2
1 ft 5 in
1 ft 4 in
None
None
5 E=>W 9
Vinyl Low-E Single Yes
0.39
0.29
Y
20.0 ft2
1 ft 5 in
1 ft 4 in
None
None
6 E=>W 11
Vinyl Low-E Single Yes
0.39
0.29
Y
15.0 ft2
1 ft 5 in
1 ft 4 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
400 ft2 400 ft2
20 ft
8 ft
11
4/5/2022 9:42 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6
FnPU RAnF_gngn IMP11T Sl1MMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000254
966.7 53.03 99.57 .0902
5
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Strip Heat/
None
COP:1 27 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Sing] SEER: 14.528.6 kBtu/hr cfm
0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ftz
DUCTS
---- Supply ----
V # Location R-Value Area
--- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1 Attic 6 75 ftz
Foyer
10 ftZ Proposed Qn Foyer --- cfm 116.0 cfm 0.08 0.50
1 1
TEMPERATURES
Programable Thermostat: N
Cooling[[ jj Jan [[ ]] Feb [[ ]] Mar
Heatin[X] Jan [X] Feb [X] Mar
Ventin [ ] Jan [ j Feb [X] Mar
Ceiling Fans:
[ ] Apr [ ] Ma [X] Jun [X] Jul X] Au Se j ]Oct
j ] Apr [ ]May [ ] Jun j ] Jul 4 ] Aug JXJ Sep [ ]
[X] A r [ ] Ma [ ] Jun [ ] Jul [ ] Au Se [X]
[ Nov
Oct [ Nov
Oct [X Nov
Dec
Dec
Dec
4/5/2022 9:42 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6
FnR.M R4n5-2n2n INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
M Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M Bath
Default(8 Ibs/sq.ft.
ft2
1 ft
0.3
Bedroom 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Great Room
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Dining
Default(8 lbs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Foyer
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall 1
Default(8 lbs/sq.ft.
ft2
ft
0.3
Laundry
Default(8 Ibs/s .ft.
ft2
ft
0.3
Hall 2
4/5/2022 9:42 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Ravina 3A Builder Name:
Street: Garage Left Permit Office:
City, State, Zip: Port St. Lucie , FL , Permit Number:
Owner: Ravinia 3A - Left Hand Garage Jurisdiction:
W
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Pxtpn(I behind piping and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire soronkler cover plates gnd walls or ceolmnas.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/5/2022 9:43 PIN EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2.. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Sgl, U=0.39
SHGC: SHGC=0.29
b. U-Factor: N/A
SHGC:
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
Garage Left, Port St. Lucie, FL,
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1168.00 ft2
b. Frame - Wood, Adjacent
R=13.0
160.00 ft2
1
c. N/A
R=
ft2
3
d. N/A
R=
ft2
Yes
11. Ceiling Type and insulation level
Insulation
Area
1
a. Under Attic (Vented)
R=30.0
1450.00 ft2
1450
b. N/A
R=
ft2
Area
c. N/A
R=
ft2
126.00 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Foyer, AH: Foyer
6 75
ft2
13. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
28.6 SEER:14.50
ft2
1.417 ft.
0.290
Area
ft2
Insulation Area
R=0.0 1450.00 ft2
R= ft2
R= ft2
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: L1L
Address of New Home:
Date: '-( -tom - 2 2
City/FL Zip:
kBtu/hr Efficiency
27.0 COP:1.00
Cap: 50 gallons
EF: 0.95
CF
-TVLE O� Sr'N. ?F`.
d C7
ter_ �
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/5/2022 9:42 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1