Loading...
HomeMy WebLinkAboutrevised electrical plan Ravinia 3A Left permit # 2202-03894Py 9 FORM R405-2020 Perm zD?7 • FLORIDA ENERGY EFFICIENCY CODEt e PUILDING CONSTRUCTION C4U 'ne Florida Department of Business and Professional RegulatiM. -residential Performance Method Project Name: Ravina 3A Builder Name: Street: Garage Left Permit Office: City, State, Zip: Port St. Lucie, FL , Permit Number: Owner. Ravinia 3A - Left Hand Garage Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41328.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1168.00 ft2 b, Frame - Wood, Adjacent R=13.0 160.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Types (1450.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1450.00 ft2 6. Conditioned floor area above grade (ft2) 1450 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(126.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Foyer, AH: Foyer R ft2 6 75 a. U-Factor: Sgl, U=0.39 126.00 ft2 SHGC: SHGC=0.29 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 28.6 SEER:14.50 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 1.417 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.290 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1450.0 sqft.) Insulation Area EF: 0.960 a. Slab -On -Grade Edge Insulation R=0.0 1450.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits CF Glass/Floor Area: 0.087 Total Proposed Modified Loads: 45.06 PASS Total Baseline Loads: 46.17 I hereby certify that the plans and specifications covered by Review of the plans and SHE ST this calculation are in compliance with the Florida Energy Code. specifications covered by this calculation indicates compliance the Florida Energy Code. ti,�,�' �• ' ,: ```;��O�;w` � PREPARED BY: with Before construction is completed { . - ?t_ �i DATE: 4-6-2022 this building will be inspected for - j 4 compliance with Section 563.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. vr�, ter;��F,✓ with the Florida Energy Code. 01) wr- T ; OWNER/AGENT:�� - BUILDING OFFICIAL: DATE: y -U -7 2 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). - Proposed Qn of 0.080 exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405 .2.3 4/5/2022 9:42 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INYU I SUMMAKY L;H1=UtXL1J I KCF'UK I PROJECT Title: Ravina 3A Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1450 Lot # Owner Name: Ravinia 3A - Left Hand Garag Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 180 Street: Garage Left Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: Port St. Lucie, Family Type: Detached FL , New/Existing: New (From Plans) , Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1450 11600 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M Bedroom 195 1560 No 2 1 1 Yes Yes Yes 2 M WIC 48 384 No 0 1 No Yes Yes 3 M Bath 84 672 No 1 1 Yes Yes Yes 4 Bedroom 3 143 1144 No 1 1 1 Yes Yes Yes 5 Bath 2 54 432 No 0 1 Yes Yes Yes 6 Bedroom 2 143 1144 No 1 1 1 Yes Yes Yes 7 Great Room 232 1856 No 2 1 Yes Yes Yes 8 Dining 128 1024 No .2 1 Yes Yes Yes 9 Kitchen 202 1616 Yes 2 1 Yes Yes Yes 10 Foyer 85 680 No 1 1 Yes Yes Yes 11 Hall 35 280 No 0 1 No Yes Yes 12 Laundry 77 616 No 0 1 Yes Yes Yes 13 Hall 24 192 No 0 1 No Yes Yes 5 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio M Bedroom 32 ft 195 ft2 _--- 1 0 0 2 Slab -On -Grade Edge Insulatio M WIC 1 ft 48 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulatio M Bath 6 ft 84 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulatio Bedroom 3 11 ft 143 ft2 ---- 1 0 0 4/5/2022 9:42 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 Fnpm Rangy -gran INPUT Sl1MMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio Bath 2 6 ft 54 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulatio Bedroom 2 11 ft 143 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulatio Great Room 30 ft 232 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulatio Dining 8 ft 128 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulatio Kitchen 12 ft 202 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulatio Foyer 19 ft 85 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulatio Hall 1 1 ft 35 ft2 _--- 1 0 0 12SIab-On-Grade Edge Insulatio Laundry 11 ft 77 ft2 ---_ 1 0 10 13SIab-On-Grade Edge Insulatio Hall 2 1 ft 24 ft2 ____ 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1571 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 22.62 ATTIC IRCC V # Type Ventilation Vent Ratio (1 in) Area RBS 1 Full attic Vented 150 1450 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) M Bedroom 30 Batt 195 ft2 0.1 Wood 2 Under Attic (Vented) M WIC 30 Batt 48 ft2 0.1 Wood 3 Under Attic (Vented) M Bath 30 Batt 84 ft2 0.1 Wood 4 Under Attic (Vented) Bedroom 3 30 Batt 143 ft2 0.1 Wood 5 Under Attic (Vented) Bath 2 30 Batt 54 ft2 0.1 Wood 6 Under Attic (Vented) Bedroom 2 30 Batt 143 ft2 0.1 Wood 7 Under Attic (Vented) Great Room 30 Batt 232 ft2 0.1 Wood 8 Under Attic (Vented) Dining 30 Batt 128 ft2 0.1 Wood 9 Under Attic (Vented) Kitchen 30 Batt 202 ft2 0.1 Wood 10 Under Attic (Vented) Foyer 30 Batt 85 ft2 0.1 Wood 11 Under Attic (Vented) Hall 1 30 Batt 35 ft2 0.1 Wood 12 Under Attic (Vented) Laundry 30 Batt 77 ft2 0.1 Wood 13 Under Attic (Vented) Hall 2 30 Batt 24 ft2 0.1 Wood 4/5/2022 9:42 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FnR&A Ran.x;_gngn INPHT .RHMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below To Space XA/M11ype 1 N=>S Exterior Concrete Block - Int InsuM Bedroom 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 2 W=>E Exterior Concrete Block - Int InsuM Bedroom 4.1 18 0 8 0 144.0 ft2 0 0 0.4 0 3 W=>E Exterior Concrete Block - Int Insul M Bath 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 4 W=>E Exterior Concrete Block - Int InsuBedroom 3 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 5 W=>E Exterior Concrete Block - Int Insul Bath 2 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 6 W=>E Exterior Concrete Block - Int InsuBedroom 2 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 7 N=>S Exterior Concrete Block - Int Inst(Breat Room 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 8 E=>W Exterior Concrete Block - Int InsdDreat Room 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 9 E=>W Exterior Concrete Block - Int Insul Dining 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 10 E=>W Exterior Concrete Block - Int Insul Kitchen 4.1 12 0 8 0 96.0 ft2 0 0 0.4 0 11 E=>W Exterior Concrete Block - Int Insul Foyer 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 12 S=>N Exterior Concrete Block - Int Insul Foyer 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 _ 13 W=>E Exterior Concrete Block - Int Insul Foyer 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 14 E=>W Exterior Concrete Block - Int Insul Laundry 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 _ 15 N=>S Garage Frame - Wood Laundry 13 7 8 56.0 ft2 0.23 0.4 0 16 N=>S Garage Frame - Wood Bedroom 2 13 13 8 104.0 ft2 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>N Insulated Foyer None .39 3 6 10 20.5 ft2 2 N=>S Insulated Laundry None .39 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => chan ed-to Worst Case. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>S 1 Vinyl Low-E Single Yes 0.39 0.29 Y 20.0 ft2 1 ft 5 in 1 ft 4 in None None 2 W=>E 4 Vinyl Low-E Single Yes 0.39 0.29 Y 15.0 ft2 1 ft 5 in 1 ft 4 in None None 3 W=>E 6 Vinyl Low-E Single Yes 0.39 0.29 Y 15.0 ft2 1 ft 5 in 1 ft 4 in None None 4 N=>S 7 Vinyl Low-E Single Yes 0.39 0.29 Y 41.0 ft2 1 ft 5 in 1 ft 4 in None None 5 E=>W 9 Vinyl Low-E Single Yes 0.39 0.29 Y 20.0 ft2 1 ft 5 in 1 ft 4 in None None 6 E=>W 11 Vinyl Low-E Single Yes 0.39 0.29 Y 15.0 ft2 1 ft 5 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft2 400 ft2 20 ft 8 ft 11 4/5/2022 9:42 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FnPU RAnF_gngn IMP11T Sl1MMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 966.7 53.03 99.57 .0902 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing] SEER: 14.528.6 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ftz DUCTS ---- Supply ---- V # Location R-Value Area --- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 75 ftz Foyer 10 ftZ Proposed Qn Foyer --- cfm 116.0 cfm 0.08 0.50 1 1 TEMPERATURES Programable Thermostat: N Cooling[[ jj Jan [[ ]] Feb [[ ]] Mar Heatin[X] Jan [X] Feb [X] Mar Ventin [ ] Jan [ j Feb [X] Mar Ceiling Fans: [ ] Apr [ ] Ma [X] Jun [X] Jul X] Au Se j ]Oct j ] Apr [ ]May [ ] Jun j ] Jul 4 ] Aug JXJ Sep [ ] [X] A r [ ] Ma [ ] Jun [ ] Jul [ ] Au Se [X] [ Nov Oct [ Nov Oct [X Nov Dec Dec Dec 4/5/2022 9:42 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FnR.M R4n5-2n2n INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 M Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M Bath Default(8 Ibs/sq.ft. ft2 1 ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Great Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 lbs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 1 Default(8 lbs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/s .ft. ft2 ft 0.3 Hall 2 4/5/2022 9:42 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Ravina 3A Builder Name: Street: Garage Left Permit Office: City, State, Zip: Port St. Lucie , FL , Permit Number: Owner: Ravinia 3A - Left Hand Garage Jurisdiction: W Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Pxtpn(I behind piping and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire soronkler cover plates gnd walls or ceolmnas. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/5/2022 9:43 PIN EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2.. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Sgl, U=0.39 SHGC: SHGC=0.29 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A Garage Left, Port St. Lucie, FL, New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1168.00 ft2 b. Frame - Wood, Adjacent R=13.0 160.00 ft2 1 c. N/A R= ft2 3 d. N/A R= ft2 Yes 11. Ceiling Type and insulation level Insulation Area 1 a. Under Attic (Vented) R=30.0 1450.00 ft2 1450 b. N/A R= ft2 Area c. N/A R= ft2 126.00 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Foyer, AH: Foyer 6 75 ft2 13. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 28.6 SEER:14.50 ft2 1.417 ft. 0.290 Area ft2 Insulation Area R=0.0 1450.00 ft2 R= ft2 R= ft2 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: L1L Address of New Home: Date: '-( -tom - 2 2 City/FL Zip: kBtu/hr Efficiency 27.0 COP:1.00 Cap: 50 gallons EF: 0.95 CF -TVLE O� Sr'N. ?F`. d C7 ter_ � *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/5/2022 9:42 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1