HomeMy WebLinkAboutENERGY EFFICIENCY CODEDocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B FORM R405-2020 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include: ❑ This Checklist ❑ Form R405-2020 report ❑ Input summary checklist that can be used for field verification (usually four pages/may be greater). ❑ Energy Performance Level (EPL) Display Card (one page) ❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements (five pages) Required prior to CO: ❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table 402.4.1.1 - one page) ❑ A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units of R - 2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 ❑ If FORM R405 duct leakage type indicates anything other than "default leakage'; then a completed 2020 Duct Leakage Test Report - Performance Method (usually one page). 2022-Jan-17 11:11:39 wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software page 1 ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Roe Residence Builder Name: Groza Builders, Inc Street: TBD Ulrich Road Permit Office: City, State, Zip: Fort Pierce, FL 34982 Permit Number: Owner: Roe Residence Jurisdiction: St. Lucie Design Location: FL, St Lucie Co Intl County: St. Lucie (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall types (4733 ft2) Insulation (R) Area (ft2) 2. Single family or multiple family Single -Family a. Blk Wall, Stuc Ext, 8" Thk, R-9 9.0 4434.90 b. Frm Wall, 1/2" Gyp Bd Ext, R-11 11.0 297.60 3. Number of units, if multiple family 1 c. N/A 4. Number of bedrooms 6 d. N/A 10. Ceiling types (2774 ft2) Insulation (R) Area (ft2) 5. Is this a worst case? Yes a. Attic, Metal Roof, R-20 Roof Dec 0.0 2773.50 6. Conditioned floor area above grade (ft2) 4946.75 b. N/A Conditioned floor area below grade (ft2) 0 c. N/A 7. Windows (640 ft2) Description Area (ft2) 11 Da .Sup: Zone 1 Attic, Ret: Zone 1 Attic, AH: A) Zone 1 6.0 170.82 a. U-Factor: Dbl Impact, 0.310 368.49 b.Sup: Zone 2 Attic, Ret: Zone 2 Attic, AH: Uncond SHGC: 0.19 b. U-Factor: Dbl Impact, 0.280 39.40 12. Cooling systems kBtu/hr Efficiency SHGC: 0.17 a.Split air source heat pump 12.4 SEER: 18.0 c. U-Factor: Dbl Impact, 0.310 144.00 b.2 additional cooling units. (See details) SHGC: 0.20 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 88.48 a.Split air source heat pump 12.3 HSPF: 9.1 SHGC: other (see detaisl) b.2 additional heating units. (See details) Area Weighted Average Overhang Depth: 4.782 ft 14. Hot water systems Area Weighted Average SHGC: 0.192 a.Multiple, see details Cap: 80 gal UEF: 1.96 8. Floor types (2773.50 ft2) Insulation (R) Area (ft2) b.Conservation features a. On Grade Depth, Tile Flr Fnsh 0.0 2545.00 (None) b. Flr Tuss, 18" Thkns, Tile Flr Fn 30.0 228.50 c. N/A 15. Credits Pstat Glass/Floor area: 0.129 Total Proposed Modified Loads: 145.59 PASS Total Baseline Loads: 174.21 I hereby certify that the plans and specifications covered by Review of the plans and specifications this calculation are in compliance with the Florida Energy covered by this calculation indicatesp Code. compliance with the Florida Energy : {"{• .n Prepared By Chris Bateman Code. Before construction is completed, this building will be inspected for u, compliance with Section 553.908 Signature S� Date 1 /17/2022 Florida Statutes. o I hereby certify that this building, as designed, is in y compliance with the lorDggutrneergV'Co•de. 1►E Own 9eT t9 Q14 �Vb�jA Building Official Name 5A96BD D32842B. 1/17/2022 SignLtu�Q t-rb�a. Date Signature Date - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2). 2022-Jan-17 11:11:39 wriglhtsoft' Right -Suite® Universal 2021 21.0.11 RSU29066 Right -Energy® Florida 2020 Section R405.4.1 Compliant Software Page 2 AM Ir, N..p6d. sa -, ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B FORM R405-2020 Building Input Summary Report PROJECT Title: Roe Residence Bedrooms: 6 Address type: Street address Building Type: FLAsBuilt Bathrooms: 5 Lot#: Owner: Roe Residence Conditioned Area: 4947 Block/Subdivision: # of Units: 1 Total Stories: 2 Platbook: Builder Name: Groza Builders, Inc Worst Case: Yes Street: TBD Ulrich Road Permit Office: Rotate An le: 0 County: St. Lucie Jurisdiction: St. Lucie Cross Ventilation: No City, State, Zip: Fort Pierce, FL 34982 Family Type: Single -Family Whole House Fan: No New/ New (From Plans) Terrain: Ocean/Lake Year Construct: Shielding: Suburban Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, St Lucie Co Intl FL -Fort _Pierce 2 41 90 70 75 486 57 Low BLOCKS # Name Area Volume 1 Zone 2 1381.25 ft2 12845.63 ft3 2 Zone 1 1163.75 ft2 10822.88 ft3 3 Zone 3 2401.75 ft2 21615.75 ft3 SPACES # Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Office 100.00 ft2 930.00 ft3 No 0 0 1 Yes Yes Yes 2 Cabana 73.50 ft2 683.55 ft3 No 0 0 1 Yes Yes Yes 3 Stairs 1A 127.50 ft2 1185.75 ft3 No 0 0 1 Yes Yes Yes 4 Game Room1 321.25 ft2 2987.63 ft3 No 0 0 1 Yes Yes Yes 5 Stairs 1 B 96.00 ft2 892.80 ft3 No 0 0 1 Yes Yes Yes 6 AHU 1 20.00 ft2 186.00 ft3 No 0 0 1 Yes Yes Yes 7 Game Room2 528.00 ft2 4910.40 ft3 No 1 0 1 Yes Yes Yes 8 Study 151.75 ft2 1411.28 ft3 No 0 1 1 Yes Yes Yes 9 Family 440.25 ft2 4094.33 ft3 No 4 0 1 Yes Yes Yes 10 Kitchen 427.00 ft2 3971.10 ft3 Yes 2 0 1 Yes Yes Yes 11 Dining 180.00 ft2 1674.00 ft3 No 0 0 1 Yes Yes Yes 12 ClSt 3 60.00 ft2 540.00 ft3 No 0 0 1 Yes Yes Yes 13 Bath 2 55.00 ft2 495.00 ft3 No 0 0 1 Yes Yes Yes 14 Bed 2 289.25 ft2 2603.25 ft3 No 0 1 1 Yes Yes Yes 15 Bed 3 162.00 ft2 1458.00 ft3 No 0 1 1 Yes Yes Yes 16 Master Bath 153.50 ft2 1381.50 ft3 No 0 0 1 Yes Yes Yes 17 Bath 4 49.50 ft2 445.50 ft3 No 0 0 1 Yes Yes Yes 18 Bed 5 226.25 ft2 2036.25 ft3 No 0 1 1 Yes Yes Yes 19 Bed 4 187.50 ft2 1687.50 ft3 No 0 1 1 Yes Yes Yes 20 Laundry 2 55.25 ft2 497.25 ft3 No 0 0 1 Yes Yes Yes 21 Clst 2 42.25 ft2 380.25 ft3 No 0 0 1 Yes Yes Yes 22 Hall 84.00 ft2 756.00 ft3 No 0 0 1 Yes Yes Yes 23 Lin 10.50 ft2 94.50 ft3 No 0 0 1 Yes Yes Yes 24 Stairs 2B 93.50 ft2 841.50 ft3 No 0 0 1 Yes Yes Yes 25 Stairs 2A 121.75 ft2 1095.75 ft3 No 0 0 1 Yes Yes Yes 26 Laundry 1 92.00 ft2 828.00 ft3 No 0 0 1 Yes Yes Yes 27 His 66.50 ft2 598.50 ft3 No 0 0 1 Yes Yes Yes 28 Master Bed 310.00 ft2 2790.00 ft3 No 0 1 1 Yes Yes Yes 29 Hers 71.25 ft2 641.25 ft3 No 0 0 1 Yes Yes Yes 30 Master Hall 124.00 ft2 1116.00 ft3 No 0 0 1 Yes Yes Yes 31 Clst 27.50 ft2 247.50 ft3 No 0 0 1 Yes Yes Yes 32 Bath 3 40.00 ft2 360.00 ft3 No 0 0 1 Yes Yes Yes 33 Wtr Clst 28.00 ft2 252.00 ft3 No 0 0 1 Yes Yes Yes 34 Pwdr Room 52.25 ft2 470.25 ft3 No 0 0 1 Yes Yes Yes 35 Bath 46.75 ft2 434.78 ft3 No 0 0 1 Yes Yes Yes 36 Pantry 33.00 ft2 306.90 ft3 No 0 0 1 Yes Yes Yes 2022-Jan-17 11:11:39 wrightSOft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right-EnergyOFlorida 2020 Section R405.4.1 Compliant Software Page AM Ir, N..p6d. sa -, ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B 1��7e7L■M1111UR1 211 FLOORS (Total Exposed Area = 2774 sq.ft.) # Floor Type Space Perimeter R-Value Area U-Factor Tile Wood Carpet 1 On Grade Depth, Tile Flr Fnsh Office 30 ft 0 100.00 ft2 0.989 1.0 0 0 2 On Grade Depth, Tile Flr Fnsh Cabana 23 ft 0 73.50 ft2 0.989 1.0 0 0 3 On Grade Depth, Tile Flr Fnsh Stairs 1A 24 ft 0 127.50 ft2 0.989 1.0 0 0 4 On Grade Depth, Tile Flr Fnsh Game Room1 18 ft 0 321.25 ft2 0.989 1.0 0 0 5 On Grade Depth, Tile Flr Fnsh Stairs 1 B 12 ft 0 96.00 ft2 0.989 1.0 0 0 6 On Grade Depth, Tile Flr Fnsh AHU 1 9 ft 0 20.00 ft2 0.989 1.0 0 0 7 On Grade Depth, Tile Flr Fnsh Game Room2 53 ft 0 528.00 ft2 0.989 1.0 0 0 8 On Grade Depth, Tile Flr Fnsh Study 12 ft 0 151.75 ft2 0.989 1.0 0 0 9 On Grade Depth, Tile Flr Fnsh Family 47 ft 0 440.25 ft2 0.989 1.0 0 0 10 On Grade Depth, Tile Flr Fnsh Kitchen 28 ft 0 427.00 ft2 0.989 1.0 0 0 11 On Grade Depth, Tile Flr Fnsh Dining 12 ft 0 180.00 ft2 0.989 1.0 0 0 12 Flr Tuss, 18" Thkns, Tile Flr Fnsh, R-30 Ins, Ove ClSt 3 16 ft 30 60.00 ft2 0.034 1.0 0 0 13 Flr Tuss, 18" Thkns, Tile Flr Fnsh, R-30 Ins, Ove Bath 2 16 ft 30 55.00 ft2 0.034 1.0 0 0 14 Flr Tuss, 18" Thkns, Tile Flr Fnsh, R-30 Ins, Ove Laundry 1 7 ft 30 68.00 ft2 0.034 1.0 0 0 sh, R-30 IFler Ins, Ove 10 30 16 On Grade Depth, Tile Fnsh Bath ft 46.75 ft2 0.989 1.0 0 0 17 On Grade Depth, Tile Flr Fnsh Pantry 0 ft 0 33.00 ft2 0.989 1.0 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or shed RoofMetal 315 ft2 61 ft2 Light N 0.75 No 0.90 No 20 23 2 Gable or shed RoofMetal 87 ft2 17 ft2 Light N 0.75 No 0.90 No 20 23 3 Gable or shed RoofMetal 2602 ft2 500 ft2 Light N 0.75 No 0.90 No 20 23 4 Gable or shed RoofMetal 673 ft2 129 ft2 Light N 0.75 No 0.90 No 20 23 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 291.00 ft2 N N 2 Full attic Unvented 0 80.75 ft2 N N 3 Full attic Unvented 0 2401.75ft2 N N 4 Full attic Unvented 0 621.00 ft2 N N CEILING (Total Exposed Area = 2774 sq.ft.) # Ceiling Type Space R-Value U-Factor Area Fraction Truss Type 1 Attic, Metal Roof, R-20 Roof Deck In Office 0 0.386 _Framing 100.00 ft2 0.10 Wood 2 Attic, Metal Roof, R-20 Roof Deck In Cabana 0 0.386 73.50 ft2 0.10 Wood 3 Attic, Metal Roof, R-20 Roof Deck In Game Room1 0 0.386 80.75 ft2 0.10 Wood 4 Attic, Metal Roof, R-20 Roof Deck In Family 0 0.386 81.50 ft2 0.10 Wood 5 Attic, Metal Roof, R-20 Roof Deck In Dining 0 0.386 36.00 ft2 0.10 Wood 6 Attic, Metal Roof, R-20 Roof Deck In Clst 3 0 0.386 60.00 ft2 0.10 Wood 7 Attic, Metal Roof, R-20 Roof Deck In Bath 2 0 0.386 55.00 ft2 0.10 Wood 8 Attic, Metal Roof, R-20 Roof Deck In Bed 2 0 0.386 289.25 ft2 0.10 Wood 9 Attic, Metal Roof, R-20 Roof Deck In Bed 3 0 0.386 162.00 ft2 0.10 Wood 10 Attic, Metal Roof, R-20 Roof Deck In Master Bath 0 0.386 153.50 ft2 0.10 Wood 11 Attic, Metal Roof, R-20 Roof Deck In Bath 4 0 0.386 49.50 ft2 0.10 Wood 12 Attic, Metal Roof, R-20 Roof Deck In Bed 5 0 0.386 226.25 ft2 0.10 Wood 13 Attic, Metal Roof, R-20 Roof Deck In Bed 4 0 0.386 187.50 ft2 0.10 Wood 14 Attic, Metal Roof, R-20 Roof Deck In Laundry 2 0 0.386 55.25 ft2 0.10 Wood 15 Attic, Metal Roof, R-20 Roof Deck In Clst 2 0 0.386 42.25 ft2 0.10 Wood 16 Attic, Metal Roof, R-20 Roof Deck In Hall 2 0 0.386 84.00 ft2 0.10 Wood 17 Attic, Metal Roof, R-20 Roof Deck In Lin 0 0.386 10.50 ft2 0.10 Wood 18 Attic, Metal Roof, R-20 Roof Deck In Stairs 2B 0 0.386 93.50 ft2 0.10 Wood 19 Attic, Metal Roof, R-20 Roof Deck In Stairs 2A 0 0.386 121.75 ft2 0.10 Wood 20 Attic, Metal Roof, R-20 Roof Deck In Laundry 1 0 0.386 92.00 ft2 0.10 Wood 21 Attic, Metal Roof, R-20 Roof Deck In His 0 0.386 66.50 ft2 0.10 Wood 22 Attic, Metal Roof, R-20 Roof Deck In Master Bed 0 0.386 310.00 ft2 0.10 Wood 23 Attic, Metal Roof, R-20 Roof Deck In Hers 0 0.386 71.25 ft2 0.10 Wood 24 Attic, Metal Roof, R-20 Roof Deck In Master Hall 0 0.386 124.00 ft2 0.10 Wood 25 Attic, Metal Roof, R-20 Roof Deck In Clst 0 0.386 27.50 ft2 0.10 Wood 26 Attic, Metal Roof, R-20 Roof Deck In Bath 3 0 0.386 40.00 ft2 0.10 Wood 27 Attic, Metal Roof, R-20 Roof Deck In Wtr Clst 0 0.386 28.00 ft2 0.10 Wood 28 Attic, Metal Roof, R-20 Roof Deck In Pwdr Room 0 0.386 52.25 ft2 0.10 Wood 2022-Jan-17 11:11:39 wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right-EnergyOFlorida 2020 Section R405.4.1 Compliant Software Page AM Ir, N..p6d. sa -, ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B INN L ■.Z1I1MR1011 WALLS (Total Exposed Area = 4733 sq.ft.) Adjacent Cavity Width Height Sheathing U- Frm. Solar Below # Ornt To Wall Type Space R-Value Ft In Ft In Area R-Value Factor Frac. Absor. Grade% 1 N Exterior BIk Wall, Stuc Ex Office 9 9 6 9 4 88.3 ft2 0 0.089 0.22 0.20 0 2 S Exterior BIk Wall, Stuc Ex Office 9 6 0 9 4 55.8 ft2 0 0.089 0.22 0.20 0 3 W Exterior Blk Wall, Stuc Ex Office 9 10 0 9 4 93.0 ft2 0 0.089 0.22 0.20 0 4 - Partition Frm Wall, 1/2" Gy Office 11 4 0 9 4 37.2 ft2 0 0.101 0.25 0.75 0 5 E Exterior BIk Wall, Stuc Ex Cabana 9 9 0 9 4 83.7 ft2 0 0.089 0.22 0.20 0 6 - Partition Frm Wall, 1/2" Gy Cabana 11 14 0 9 4 130.2 ft2 0 0.101 0.25 0.75 0 7 S Exterior BIk Wall, Stuc Ex Stairs 1A 9 15 0 9 4 139.5 ft2 0 0.089 0.22 0.20 0 8 W Exterior Blk Wall, Stuc Ex Stairs 1A 9 8 6 9 4 79.1 ft2 0 0.089 0.22 0.20 0 9 S Exterior BIk Wall, Stuc Ex Game Room1 9 5 0 9 4 46.5 ft2 0 0.089 0.22 0.20 0 10 W Exterior BIk Wall, Stuc Ex Game Room1 9 12 6 9 4 116.3 ft2 0 0.089 0.22 0.20 0 11 W Exterior BIk Wall, Stuc Ex Stairs 1 B 9 12 0 9 4 111.6 ft2 0 0.089 0.22 0.20 0 12 N Exterior BIk Wall, Stuc Ex AHU 1 9 4 0 9 4 37.2 ft2 0 0.089 0.22 0.20 0 13 W Exterior BIk Wall, Stuc Ex AHU 1 9 5 0 9 4 46.5 ft2 0 0.089 0.22 0.20 0 14 N Exterior Blk Wall, Stuc Ex Game Room2 9 36 6 9 4 339.5 ft2 0 0.089 0.22 0.20 0 15 E Exterior BIk Wall, Stuc Ex Game Room2 9 16 0 9 4 148.8 ft2 0 0.089 0.22 0.20 0 16 E Exterior BIk Wall, Stuc Ex Study 9 12 0 9 4 111.6 ft2 0 0.089 0.22 0.20 0 17 E Exterior BIk Wall, Stuc Ex Family 9 17 6 9 4 162.8 ft2 0 0.089 0.22 0.20 0 18 W Exterior BIk Wall Stuc Ex Family 9 15 0 9 4 139.5 ft2 0 0.089 0.22 0.20 0 19 - Partition Frm Wall, 1/2" Gy Family 11 14 0 9 4 130.2 ft2 0 0.101 0.25 0.75 0 20 N Exterior BIk Wall, Stuc Ex Kitchen 9 4 0 9 4 37.2 ft2 0 0.089 0.22 0.20 0 21 E Exterior BIk Wall, Stuc Ex Kitchen 9 19 6 9 4 181.4 ft2 0 0.089 0.22 0.20 0 22 S Exterior BIk Wall, Stuc Ex Kitchen 9 4 0 9 4 37.2 ft2 0 0.089 0.22 0.20 0 23 W Exterior BIk Wall, Stuc Ex Dinincl 9 12 0 9 4 111.6 ft2 0 0.089 0.22 0.20 0 24 N Exterior Blk Wall, Stuc Ex Clst 3 9 10 0 9 0 90.0 ft2 0 0.089 0.22 0.20 0 25 E Exterior BIk Wall, Stuc Ex Clst 3 9 6 0 9 0 54.0 ft2 0 0.089 0.22 0.20 0 26 E Exterior BIk Wall, Stuc Ex Bath 2 9 5 6 9 0 49.5 ft2 0 0.089 0.22 0.20 0 27 S Exterior BIk Wall, Stuc Ex Bath 2 9 10 0 9 0 90.0 ft2 0 0.089 0.22 0.20 0 28 N Exterior BIk Wall, Stuc Ex Bed 2 9 19 6 9 0 175.5 ft2 0 0.089 0.22 0.20 0 29 E Exterior Blk Wall, Stuc Ex Bed 2 9 4 0 9 0 36.0 ft2 0 0.089 0.22 0.20 0 30 E Exterior BIk Wall, Stuc Ex Bed 3 9 12 0 9 0 108.0 ft2 0 0.089 0.22 0.20 0 31 N Exterior BIk Wall, Stuc Ex Master Bath 9 4 0 9 0 36.0 ft2 0 0.089 0.22 0.20 0 32 E Exterior BIk Wall, Stuc Ex Master Bath 9 8 0 9 0 72.0 ft2 0 0.089 0.22 0.20 0 33 N Exterior BIk Wall, Stuc Ex Bath 4 9 3 6 9 0 31.5 ft2 0 0.089 0.22 0.20 0 34 S Exterior BIk Wall, Stuc Ex Bath 4 9 3 6 9 0 31.5 ft2 0 0.089 0.22 0.20 0 35 W Exterior Blk Wall, Stuc Ex Bath 4 9 5 6 9 0 49.5 ft2 0 0.089 0.22 0.20 0 36 W Exterior BIk Wall, Stuc Ex Bed 5 9 13 0 9 0 117.0 ft2 0 0.089 0.22 0.20 0 37 W Exterior BIk Wall, Stuc Ex Bed 4 9 6 0 9 0 54.0 ft2 0 0.089 0.22 0.20 0 38 N Exterior BIk Wall, Stuc Ex Hall 2 9 21 0 9 0 189.0 ft2 0 0.089 0.22 0.20 0 39 W Exterior BIk Wall, Stuc Ex Hall 2 9 4 0 9 0 36.0 ft2 0 0.089 0.22 0.20 0 40 S Exterior Blk Wall, Stuc Ex Stairs 2B 9 8 0 9 0 72.0 ft2 0 0.089 0.22 0.20 0 41 W Exterior BIk Wall, Stuc Ex Stairs 2B 9 13 0 9 0 117.0 ft2 0 0.089 0.22 0.20 0 42 N Exterior BIk Wall, Stuc Ex Stairs 2A 9 3 0 9 0 27.0 ft2 0 0.089 0.22 0.20 0 43 S Exterior BIk Wall, Stuc Ex Stairs 2A 9 6 6 9 0 58.5 ft2 0 0.089 0.22 0.20 0 44 W Exterior BIk Wall, Stuc Ex Stairs 2A 9 8 6 9 0 76.5 ft2 0 0.089 0.22 0.20 0 45 S Exterior Blk Wall, Stuc Ex Laundry 1 9 2 0 9 0 18.0 ft2 0 0.089 0.22 0.20 0 46 W Exterior BIk Wall, Stuc Ex Laundry 1 9 8 0 9 0 72.0 ft2 0 0.089 0.22 0.20 0 47 S Exterior BIk Wall, Stuc Ex His 9 9 6 9 0 85.5 ft2 0 0.089 0.22 0.20 0 48 W Exterior BIk Wall, Stuc Ex His 9 7 0 9 0 63.0 ft2 0 0.089 0.22 0.20 0 49 E Exterior BIk Wall, Stuc Ex Master Bed 9 17 6 9 0 157.5 ft2 0 0.089 0.22 0.20 0 50 S Exterior Blk Wall, Stuc Ex Master Bed 9 17 6 9 0 157.5 ft2 0 0.089 0.22 0.20 0 51 E Exterior BIk Wall, Stuc Ex Bath 3 9 5 0 9 0 45.0 ft2 0 0.089 0.22 0.20 0 52 E Exterior BIk Wall, Stuc Ex Wtr Clst 9 7 0 9 0 63.0 ft2 0 0.089 0.22 0.20 0 53 S Exterior BIk Wall, Stuc Ex Wtr Clst 9 4 0 9 0 36.0 ft2 0 0.089 0.22 0.20 0 DOORS (Total Exposed Area = 68 sq.ft.) Width Height # Ornt Door Type Space Storms U-Value Ft In Ft In Area 1 E Fbrgls Door Cabana None 0.127 2 6 8 0 20.0 ft2 2 N Fbrgls Door Game Room2 None 0.127 3 0 8 0 24.0 ft2 3 W Fbrgls Door Family None 0.127 3 0 8 0 24.0 ft2 2022-Jan-17 11:11:39 wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right-EnergyOFlorida 2020 Section R405.4.1 Compliant Software Page AM Ir, N..p6d. sa -, ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B INN L■.Z1-111MM H WINDOWS (Total Exposed Area = 640 sq.ft.) Wall Overhang Interior # Ornt ID Frame Panes NFRC U-Factor SHGC Impact W x H, Area Depth Separation Shade Screening 1 W 3 Metal Low-E Double Yes 0.310 0.19 Yes 3'0" x 5'2" , 16 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 2 W 8 Metal Low-E Double Yes 0.280 0.17 Yes 2'5" x 4'1" , 10 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 3 W 10 Metal Low-E Double Yes 0.310 0.19 Yes 9'1" x 6'3" , 57 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 4 N 14 Metal Low-E Double Yes 0.310 0.19 Yes 9'0" x 5'2" , 47 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 5 E 15 Metal Low-E Double Yes 0.310 0.20 Yes 6'0" x 8'0" , 48 ft2 10 ft 0 in 1 ft 0 in Blinds 45' outdoor 6 E 16 Metal Low-E Double Yes 0.310 0.19 Yes 6'1" x 5'2" , 31 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 7 E 17 Metal Low-E Double Yes 0.310 0.20 Yes 12'0" x 8'0" , 96 ft2 12 ft 0 in 1 ft 0 in Blinds 45' outdoor 8 W 18 Metal Low-E Double Yes 0.310 0.19 Yes 6'0" x 6'1" , 37 ft2 9 ft 4 in 1 ft 0 in Blinds 45' outdoor 9 N 20 Metal Low-E Double Yes 0.260 0.24 Yes 1'0" x 4'2" , 4 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 10 E 21 Metal Low-E Double Yes 0.310 0.19 Yes 4'5" x 4'2" , 18 ft2 9 ft 0 in 1 ft 0 in Blinds 45' outdoor 11 S 22 Metal Low-E Double Yes 0.260 0.24 Yes 1'0" x 4'2" , 4 ft2 12 ft 0 in 1 ft 0 in Blinds 45' outdoor 12 W 23 Metal Low-E Double Yes 0.310 0.19 Yes 6'1" x 6'3" , 38 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 13 S 27 Metal Low-E Double Yes 0.270 0.18 Yes 3'0" x 1'5" 4 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 14 N 28 Metal Low-E Double Yes 0.310 0.19 Yes 6'0" x 5'2" , 31 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 15 E 30 Metal Low-E Double Yes 0.310 0.19 Yes 6'1" x 5'2" , 31 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 16 E 32 Metal Low-E Double Yes 0.260 0.22 Yes 0'10" x 3'4" , 3 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 17 W 35 Metal Low-E Double Yes 0.320 0.19 Yes 2'0" x 5'2" , 10 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 18 W 36 Metal Low-E Double Yes 0.310 0.19 Yes 6'0" x 5'2" , 31 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 19 W 37 Metal Low-E Double Yes 0.320 0.19 Yes 5'0" x 4'2" , 21 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 20 N 38 Metal Low-E Double Yes 0.280 0.17 Yes 2'5" x 4'0" , 10 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 21 W 39 Metal Low-E Double Yes 0.320 0.19 Yes 2'6" x 4'0" , 10 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 22 W 41 Metal Low-E Double Yes 0.280 0.17 Yes 2'6" x 4'0" , 10 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 23 W 44 Metal Low-E Double Yes 0.280 0.17 Yes 2'5" x 4'1" , 10 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 24 W 46 Metal Low-E Double Yes 0.320 0.19 Yes 5'0" x 3'2" , 16 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 25 E 49 Metal Low-E Double Yes 0.310 0.19 Yes 6'2" x 27' , 16 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 26 S 50 Metal Low-E Double Yes 0.260 0.24 Yes 6'0" x 1'4" , 8 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 27 S 50 Metal Low-E Double Yes 0.310 0.19 Yes 3'0" x 5'2" , 16 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 28 E 51 Metal Low-E Double Yes 0.320 0.19 Yes 2'0" x 2'0" , 4 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor 29 E 52 Metal Low-E Double Yes 0.320 0.19 Yes 2'0" x 2'0" 4 ft2 2 ft 0 in 1 ft 0 in Blinds 45' outdoor GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 0 INFILTRATION # Scope Method SLA CFM 50 ELA E LA ACH ACH 50 1 Wholehouse Blower Door 0.000408 5283 290.6 545.7 0.65 7.00 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric strip AFUE: 100.0 16.4 kBtu/hr 1 sys#1 2 Split air source heat pump HSPF: 9.1 12.3 kBtu/hr 2 sys#2 3 Electric stri AFUE: 100.0 24.1 kBtu/hr 3 s s#3 COOLING SYSTEM # System TVpe Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Split air conditioner SEER: 16.0 24.0 kBtu/hr 800 cfm 0.72 1 sys#1 2 Split air source heat pump SEER: 18.0 12.4 kBtu/hr 413 cfm 0.70 2 sys#2 3 Split air conditioner SEER: 16.0 29.0 kBtu/hr 967 cfm 0.71 3 s s#3 HOT WATER SYSTEM # System Type Subtype Location EF Cap Use SetPnt Conservation 1 Electric conventional 1.96 UEF 80 gal 90 gal 120 T None 2 Electric conventional 1.96 LIE 80 al 90 al 120 T None DUCTS --------- Supply --------- --------- Return --------- Air CFM 25 Percent HVAC # # Location R-Value Area Location Area Leakage Type Handler Out Leakage ON RLF Heat Cool 1 Zone 2 Attic 6.0 232 ft2 Zone 2 Attic 67 ft2 Default Leakage Uncond (Default) 6.00 0.08 1 1 2 Zone 1 Attic 6.0 171 ft2 Zone 1 Attic 8 ft2 Default Leakage Zone 1 Default 6.00 0.08 2 2 3 Zone 3 Attic 6.0 439 ft2 Zone 3 Attic 60 ft2 Default Leakage Zone 3 Attic Default 6.00 0.08 3 3 2022-Jan-17 11:11:39 wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 6 AM Ir, N..p6d. sa -, ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B INN L ■.ZIIMWI&H TEMPERATURES Programmable Thermostat: Y Ceiling Fans: Cooling [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec Heating [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec Venting [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec Thermostat Schedule: Florida Building Code, 7th Edition Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling (WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating (WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating (WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 2022-Jan-17 11:11:39 wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 7 ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX = 84 The lower the EnergyPerformance Index, the more efficient the home. 1. New home or addition 1. New (From Plans) 12. Ducts, location & insulation level a. Supply ducts: R 6.0 2. Single-family or multiple -family 2. Single -Family b. Return ducts: R 6.0 c. AHU location: Zone 1,Uncond,Zone 3 Attic 3. Number of units, if multiple -family 3. 1 13. Cooling systems Capacity 65.4 4. Number of bedrooms 4. 6 a. Split system: SEER 16.00 b. Single package: SEER 5. Is this a worst case? (yes/no) 5. Yes c. Ground/water source: SEER/COP d. Room unit/PTAC: EER 6. Conditioned floor area (ft2) 6. 4946.75 e. Other: 7. Windows, type and area* 14. Heating systems Capacity 52.7 a. U-Factor: Db7drnpact(Avq), 0.307 a. Split system heat pump: HSPF 9.10 b. Solar Heat Gain Coefficient (SHGC): 7b. 0.19 b. Single package heat pump: HSPF c. Area (ft2) 7c. 640 c. Electric resistance: COP 100.00 d. Gas furnace, natural gas: AFUE 8. Skylights e. Gas furnace, LPG: AFUE a. U-Factor: 8a. f. Other: b. Solar Heat Gain Coefficient (SHGC): 8b. 15. Water heating systems 9. Floor type, insulation level a. Electric resistance: 1.96 UEF a. Slab -on -grade (R-value): 9a. 0.0 b. Gas fired, natrual gas: b. Wood, raised (R-value): 9b. 30.0 c. Gas fired, LPG: c. Concrete, raised (R-value) 9c. d. Solar system with tank: e. Dedicated heat pump with tank: 10 Wall type and insulation: f. Heat recovery unit: HeatRec% a. Exterior: g. Other: 1. Wood frame (Insulation R-value): 10a1. 2. Masonry (Insulation R-value): 10a2. 9 16. HVAC credits claimed (Performance Method) b. Adjacent: a. Ceiling fans: 1. Wood frame (Insulation R-value): 10b1. 11 b. Cross ventilation: 2. Masonry (Insulation R-value): 10b2. c. Whole house fan: d. Multizone cooling credit: Yes 11. Ceiling type and insulation level e. Multizone heating credit: Yes a. Under attic (R-value): 1 la. 0.0 f. Programmable thermostat: Yes b. Single assembly (R-value): 11 b. c. Knee walls/skylight walls (R-value) 11c. d. Radiant barrier installed 11d. *Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. DocuSigned by: Ce:)6LL Builder Signatu 9A,6" Gya'�a, Date: 111712022 5A96BDBAD32842B... Address of New Home: TBD Ulrich Road City/FL Zip: Fort Pierce, FL 34982 2022-Jan-17 11:11:39 wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software page 8 ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B FORM R405-2020 Florida Building Code, Energy Conservation, 7th Edition (2020) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: TBD Ulrich Road PERMIT #: Fort Pierce, FL 34982 MANDATORY REQUIREMENTS - See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statues) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. completed and signed by the builder The building official shall verify that the EPL display card accurately reflects the plans and specifications submitted to demonstrate compliance for the building. A copy of the EPL display card can be found in Appendix RD. SECTION R402 BUILDING THERMAL ENVELOP R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. El R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance w ith the manufacturer's instructions and the criteria listed in Table 402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. ElR402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeledin accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight-figging doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. ElR402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 2022-Jan-17 11:11:39 wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 9 ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B FORM R405-2020 MANDATORY REQUIREMENTS -(Continued) ❑ R402.4.4 Rooms containing fuel -burning appliances In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent apliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS ❑ R403.1 Controls El R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing (Mandatory). All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. rl R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Post construction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is required for Section R405 compliance where credit is taken for leakage, and a duct air leakage Qn to the outside of less than 0.080 (where Qn = duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals) is indicated in the compliance report for the proposed design. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building Cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C) or below 55°F (13°C) shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance, and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace termperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. El R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for how water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 2022-Jan-17 11:11:39 wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 10 ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B FORM R405-2020 MANDATORY REQUIREMENTS -(Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.5.6 Water heater efficiencies (Mandatory). El R403.5.6.1 Storage water heater temperature controls. R403.5.6.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140oF (38°C to 60oC). ❑ R403.5.6.1.2 shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. ❑ R403.5.6.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water heating system. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation, including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. El R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. ❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure of for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19, space permitting, or R-10 otherwise. ❑ R403.7 Heating and cooling equipment. R403.7.1 Equipment sizing (Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved methodologies, heating and cooling calculation based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM CFM MINIMUM EFFICACY (a) CFM/WATT AIRFLOW RATE MAXIMUM CFM HRV or ERV Any 1.2 cfm/watt Any Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt < 90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm - 28.3 L/min. (a) When tested in accordance HVI Standard 916 2022-Jan-17 11:11:39 wriglhtsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 11 ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B MANDATORY REQUIREMENTS -(Continued) ❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. ❑ R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1 El R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls (Mandatory). Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system hen the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that w ill allow shutoff w hen the outdoor temperature is above 40°F (4.8°C). R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. rl R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. El R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operations. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. ❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor- retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. ❑ R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 2022-Jan-17 11:11:39 wrigihtsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 12 ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B MANDATORY REQUIREMENTS - (Continued) ❑ R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. 0 R403.11 Portable spas (Mandatory). The energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. ❑ R403.13 Dehumidifiers (Mandatory) If installed, a dehumidifier shall conform to the following requirements: 1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/ kWh if the total dehumidifier capacity for the house is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day. 2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air. 3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2. 4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code, Residential. ❑ R403.13.1 Ducted dehumidifiers Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13, conform to the following requirements: 1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct. 2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system, a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct. 3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the central cooling evaporator coil. 4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS ❑ R404.1 Lighting equipment (Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an efficacy of at least 45 lumens -per -watt or shall utilize lamps with an efficacy of not less than 65 lumens -per -watt. Exception: Low -voltage lighting. ❑ R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 2022-Jan-17 11:11:39 wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 13 ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B FORM R405-2020 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Roe Residence Builder Name Groza Builders, Inc Street: TBD Ulrich Road Permit Office: City, State, Zip: Fort Pierce, FL 34982 Permit Number: Owner: Roe Residence Jurisdiction: St. Lucie Design Location: FL, St Lucie Cc Intl COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the requirements building envelope. The exterior thermal envelope Air -permeable insulation shall not be used as a pp El4 contains a continuous barrier. Breaks orjoints in the g e air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit The insulation in any dropped ceiling/soffit shall be aligned with the insulation and any shall be aligned with the air barrier. gaps in the air barrier shall be sealed. ❑ Access openings, drop down stairs or knee wall doors to unconditioned attics paces shall be sealed. Walls The junction of the foundation and sill plate Cavities with corners and headers of frame walls shall be sealed.The junction of the top plate shall be insulated by completely filling the cavity and the top of exterior walls shall be sealed. with a material having a thermal resistance of R-3 ❑ Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier Windows, skylights The space between window/doorjambs and framing, framing ❑ and doors and skylights and shall be sealed. Rim joists are insulated and include an air Rim joists shall be insulated. ❑ Rim joists barrier. Floors (including The air barrier shall be installed at any exposed Floor framing cavity Insulation shall be installed above -garage and edge of insulation. to maintain permanent contact with the underside cantilevered floors) of subfloor decking, or floor framing cavity insulation shall be permitted to be in contact ❑ with the top sideof sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space Exposed earth in unvented crawl spaces shall be Where provided in lieu of floor insulation, walls covered with a Class I vapor retarder with insulation shall be permanently attached ❑ overlapping joints taped. to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall ❑ be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that ❑ on installation readily conforms to the available cavity spaces. Garage Air sealing shall be provided between the garage ❑ separation and conditioned spaces. Recessed Recessed light fixtures installed in the building Recessed light fixtures installed in the lighting thermal envelope shall be sealed to the finished surface. building thermal envelope shall be air tight ❑ and IC rated. Plumbing and Batt insulation shall be cut neatly to fit around wiring wiring and plumbing in exterior walls, or insulation that on installation readily conforms ❑ to available space shall extend behind piping and wiring. Shower/tub on The air barrier shall be installed behind Exterior walls adjacent to showers and tubs exterior wall electrical or communication boxes or air -sealed shall be insulated. ❑ boxes shall be installed. Electrical/phone The air barrier shall be installed behind box on exterior electrical or communication boxes or air -sealed ❑ walls boxes shall be installed. HVAC register HVAC supply and return register boots that penetrate boots building thermal envelope shall be sealed to the ❑ subfloor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers sprinklers shall only be sealed in a manner that is recommended by the manufacturer. ❑ Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. Ri h 2022-Jan-1711:11:39 wrlghtSof# g t-Suite® Universal 2021 21.0.11 RSU29066 Right -Energy® Florida 2020 Section R405.4.1 Compliant Software Page 14 AN W. N­w.�: . , ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B FORM R405-2020 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction: St. Lucie Permit Number: Job Information Builder: Groza Builders, Inc Community: Lot: Address: TBD Ulrich Road Unit: City: Fort Pierce State: FL Zip: 34982 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method. ❑ PRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2. building or dwelling unit shall be tested and verified as having an air leakage rate of not ❑The PERFORMANCE or ERI METHOD exceeding the selected ACH(50) value, as shown on FORM R405-2020 (Performance) or R406-2020 (ERI), section labeled as Infiltration, sub -section ACH50. ACH(50) specified on Form R405-2020-Energy Calc (Performance) or R406-2020 (ERI): 7.000 x60 _ 45284 =_ Method for calculating building volume: _ CFM(50) Building Volume ACH(50) ❑ Retrieved from architectural plans ❑ PASS E Code software calculated El Field measured and calculated ❑ When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues, or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or and approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 2022-Jan-17 11:11:39 wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 15 ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B FORM R405-2020 Duct Leakage Test Report Residential Perscriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction: St. Lucie Job Information Permit Number: Builder: Groza Builders, Inc Community: Lot: Address: TBD Ulrich Road Unit: City: Fort Pierce State: FL Zip: 34982 Duct Leakage Test Results System 1 cfm25 System 2 cfm25 System 3 cfm25 Sum of any additional systems cfm25 Total of all systems cfm25 4947 = _ On Total of all Total Conditioned systems Square Footage ❑ PASS ❑ FAIL ❑ Prescriptive Method cfm25 (Total) To qualify as "substantially leak free" Qn Total must be less than or equal to 0.04 if air handler unit is installed. If air handler unit is not installed, Qn Total must be less than or equal to 0.03. This testing method meets the requirements in accordance with Section R403.3.3. Is the air handler unit installed ❑ YES(- 0.04 Qn) during testing? ❑ NO (< 0.03Qn) ❑ Performance / ERI Method cfm25 (Out or Total) To qualify using this method, Qn must be not greater than the proposed duct leakage Qn specified on Form R405-2020 or R406-2020. Leakage Type selected on Form Qn specified on Form R405-2020 R405-2020 (Energy Calc) or R406-2020 (Energy Calc) or R406-2020 Default Leakage 0.08 Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statues. Testing Company Company Name: Phone: I hereby verify that the above duct leakage test results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 2022-Jan-17 11:11:39 wrlghtsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software page 16 ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B Reference Home Characteristics Roe Residence Title: TBD Ulrich Road GBI TBD Ulrich Road Fort Pierce, FL 34982 FLBase202O Above -grade Walls (Uo) 0.084 Above -grade Wall Solar Absorptance 0.75 Above -grade Wall Infared Emittance 0.90 Basement Walls (Uo) n/a Above -grade Floors (Uo) n/a Slab Insulation R-Value 0.0 Ceilings (Uo) 0.030 Roof Solar Absorptance 0.75 Roof Infared Emittance 0.90 Attic Vent Area (ft2) 0.97 Crawls pace Vent Area (ft2) n/a Exposed Masonry Floor Area (ft2) 633.20 Carpet & Pad R-Value 2.0 Door Area (ft2) 0.00 Door U-Factor n/a North Window Area (ft2) 102.30 South Window Area (ft2) 154.10 East Window Area (ft2) 154.10 West Window Area (ft2) 154.10 Window U-Factor 0.400 Window SHGC (Heating) 0.2169 Window SHGC (Cooling) 0.2169 ACH50 7.00 Internal Gains * (Btu/day) 196057 Water heater gallons per day 270.00 Water Heater set point temperature 120.00 Water heater efficiency rating 2.59 Labeled Heating System Rating and Efficiency HSPF = 8.2 Labeled Cooling System Rating and Efficiency SEER = 14.0 Air Distribution System Efficiency 0.88 Thermostat Type Manual Heating Thermostat Settings 72.0 (All hours) TMY City: FL -Fort -Pierce