FORM R405-2020
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the residential
Simulated Performance method shall include:
❑ This Checklist
❑ Form R405-2020 report
❑ Input summary checklist that can be used for field verification (usually four pages/may be greater).
❑ Energy Performance Level (EPL) Display Card (one page)
❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
❑ Mandatory Requirements (five pages)
Required prior to CO:
❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table 402.4.1.1 - one page)
❑ A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units
of R - 2 Occupancies and multiple attached single family dwellings to comply with Section C402.5
❑ If FORM R405 duct leakage type indicates anything other than "default leakage'; then a completed 2020 Duct
Leakage Test Report - Performance Method (usually one page).
2022-Jan-17 11:11:39
wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software page 1
...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Roe Residence
Builder Name: Groza Builders, Inc
Street: TBD Ulrich Road
Permit Office:
City, State, Zip: Fort Pierce, FL 34982
Permit Number:
Owner: Roe Residence
Jurisdiction: St. Lucie
Design Location: FL, St Lucie Co Intl
County: St. Lucie (Florida Climate Zone 2)
1. New construction or existing New (From Plans)
9. Wall types (4733 ft2)
Insulation (R) Area (ft2)
2. Single family or multiple family Single -Family
a. Blk Wall, Stuc Ext, 8" Thk, R-9
9.0 4434.90
b. Frm Wall, 1/2" Gyp Bd Ext, R-11
11.0 297.60
3. Number of units, if multiple family 1
c. N/A
4. Number of bedrooms 6
d. N/A
10. Ceiling types (2774 ft2)
Insulation (R) Area (ft2)
5. Is this a worst case? Yes
a. Attic, Metal Roof, R-20 Roof Dec
0.0 2773.50
6. Conditioned floor area above grade (ft2) 4946.75
b. N/A
Conditioned floor area below grade (ft2) 0
c. N/A
7. Windows (640 ft2) Description Area (ft2)
11 Da
.Sup: Zone 1 Attic, Ret: Zone 1 Attic, AH:
A)
Zone 1 6.0 170.82
a. U-Factor: Dbl Impact, 0.310 368.49
b.Sup: Zone 2 Attic, Ret: Zone 2 Attic, AH:
Uncond
SHGC: 0.19
b. U-Factor: Dbl Impact, 0.280 39.40
12. Cooling systems
kBtu/hr Efficiency
SHGC: 0.17
a.Split air source heat pump
12.4 SEER: 18.0
c. U-Factor: Dbl Impact, 0.310 144.00
b.2 additional cooling units. (See details)
SHGC: 0.20
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 88.48
a.Split air source heat pump
12.3 HSPF: 9.1
SHGC: other (see detaisl)
b.2 additional heating units. (See details)
Area Weighted Average Overhang Depth: 4.782 ft
14. Hot water systems
Area Weighted Average SHGC: 0.192
a.Multiple, see details
Cap: 80 gal
UEF: 1.96
8. Floor types (2773.50 ft2) Insulation (R) Area (ft2)
b.Conservation features
a. On Grade Depth, Tile Flr Fnsh 0.0 2545.00
(None)
b. Flr Tuss, 18" Thkns, Tile Flr Fn 30.0 228.50
c. N/A
15. Credits Pstat
Glass/Floor area: 0.129 Total Proposed Modified Loads: 145.59
PASS
Total Baseline
Loads: 174.21
I hereby certify that the plans and specifications covered by
Review of the plans and specifications
this calculation are in compliance with the Florida Energy
covered by this calculation indicatesp
Code.
compliance with the Florida Energy
: {"{• .n
Prepared By Chris Bateman
Code. Before construction is completed,
this building will be inspected for
u,
compliance with Section 553.908
Signature S� Date 1 /17/2022
Florida Statutes.
o
I hereby certify that this building, as designed, is in
y
compliance with the lorDggutrneergV'Co•de.
1►E
Own 9eT t9 Q14 �Vb�jA
Building Official Name
5A96BD D32842B. 1/17/2022
SignLtu�Q t-rb�a. Date
Signature Date
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2).
2022-Jan-17 11:11:39
wriglhtsoft' Right -Suite® Universal 2021 21.0.11 RSU29066 Right -Energy® Florida 2020 Section R405.4.1 Compliant Software Page 2
AM Ir, N..p6d. sa -, ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
FORM R405-2020
Building Input Summary Report
PROJECT
Title:
Roe Residence
Bedrooms:
6
Address type:
Street address
Building Type: FLAsBuilt
Bathrooms:
5
Lot#:
Owner:
Roe Residence
Conditioned Area:
4947
Block/Subdivision:
# of Units:
1
Total Stories:
2
Platbook:
Builder
Name: Groza Builders,
Inc
Worst Case:
Yes
Street:
TBD Ulrich Road
Permit Office:
Rotate
An le:
0
County:
St. Lucie
Jurisdiction:
St. Lucie
Cross
Ventilation:
No
City,
State, Zip:
Fort Pierce,
FL
34982
Family
Type: Single -Family
Whole
House Fan:
No
New/
New (From
Plans)
Terrain:
Ocean/Lake
Year Construct:
Shielding:
Suburban
Comment:
CLIMATE
IECC Design Temp
Int Design Temp
Heating
Design
Daily Temp
Design Location
TMY Site
Zone 97.5
% 2.5 %
Winter
Summer
Degree Days
Moisture
Range
FL, St Lucie Co Intl
FL -Fort _Pierce
2 41
90
70
75
486
57
Low
BLOCKS
#
Name
Area
Volume
1
Zone 2
1381.25 ft2
12845.63 ft3
2
Zone 1
1163.75 ft2
10822.88 ft3
3
Zone 3
2401.75 ft2
21615.75 ft3
SPACES
#
Area
Volume
Kitchen
Occupants Bedrooms
InfilID
Finished
Cooled
Heated
1
Office
100.00 ft2
930.00 ft3
No
0
0
1
Yes
Yes
Yes
2
Cabana
73.50 ft2
683.55 ft3
No
0
0
1
Yes
Yes
Yes
3
Stairs 1A
127.50 ft2
1185.75 ft3
No
0
0
1
Yes
Yes
Yes
4
Game Room1
321.25 ft2
2987.63 ft3
No
0
0
1
Yes
Yes
Yes
5
Stairs 1 B
96.00 ft2
892.80 ft3
No
0
0
1
Yes
Yes
Yes
6
AHU 1
20.00 ft2
186.00 ft3
No
0
0
1
Yes
Yes
Yes
7
Game Room2
528.00 ft2
4910.40 ft3
No
1
0
1
Yes
Yes
Yes
8
Study
151.75 ft2
1411.28 ft3
No
0
1
1
Yes
Yes
Yes
9
Family
440.25 ft2
4094.33 ft3
No
4
0
1
Yes
Yes
Yes
10
Kitchen
427.00 ft2
3971.10 ft3
Yes
2
0
1
Yes
Yes
Yes
11
Dining
180.00 ft2
1674.00 ft3
No
0
0
1
Yes
Yes
Yes
12
ClSt 3
60.00 ft2
540.00 ft3
No
0
0
1
Yes
Yes
Yes
13
Bath 2
55.00 ft2
495.00 ft3
No
0
0
1
Yes
Yes
Yes
14
Bed 2
289.25 ft2
2603.25 ft3
No
0
1
1
Yes
Yes
Yes
15
Bed 3
162.00 ft2
1458.00 ft3
No
0
1
1
Yes
Yes
Yes
16
Master Bath
153.50 ft2
1381.50 ft3
No
0
0
1
Yes
Yes
Yes
17
Bath 4
49.50 ft2
445.50 ft3
No
0
0
1
Yes
Yes
Yes
18
Bed 5
226.25 ft2
2036.25 ft3
No
0
1
1
Yes
Yes
Yes
19
Bed 4
187.50 ft2
1687.50 ft3
No
0
1
1
Yes
Yes
Yes
20
Laundry 2
55.25 ft2
497.25 ft3
No
0
0
1
Yes
Yes
Yes
21
Clst 2
42.25 ft2
380.25 ft3
No
0
0
1
Yes
Yes
Yes
22
Hall
84.00 ft2
756.00 ft3
No
0
0
1
Yes
Yes
Yes
23
Lin
10.50 ft2
94.50 ft3
No
0
0
1
Yes
Yes
Yes
24
Stairs 2B
93.50 ft2
841.50 ft3
No
0
0
1
Yes
Yes
Yes
25
Stairs 2A
121.75 ft2
1095.75 ft3
No
0
0
1
Yes
Yes
Yes
26
Laundry 1
92.00 ft2
828.00 ft3
No
0
0
1
Yes
Yes
Yes
27
His
66.50 ft2
598.50 ft3
No
0
0
1
Yes
Yes
Yes
28
Master Bed
310.00 ft2
2790.00 ft3
No
0
1
1
Yes
Yes
Yes
29
Hers
71.25 ft2
641.25 ft3
No
0
0
1
Yes
Yes
Yes
30
Master Hall
124.00 ft2
1116.00 ft3
No
0
0
1
Yes
Yes
Yes
31
Clst
27.50 ft2
247.50 ft3
No
0
0
1
Yes
Yes
Yes
32
Bath 3
40.00 ft2
360.00 ft3
No
0
0
1
Yes
Yes
Yes
33
Wtr Clst
28.00 ft2
252.00 ft3
No
0
0
1
Yes
Yes
Yes
34
Pwdr Room
52.25 ft2
470.25 ft3
No
0
0
1
Yes
Yes
Yes
35
Bath
46.75 ft2
434.78 ft3
No
0
0
1
Yes
Yes
Yes
36
Pantry
33.00 ft2
306.90 ft3
No
0
0
1
Yes
Yes
Yes
2022-Jan-17 11:11:39
wrightSOft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right-EnergyOFlorida 2020 Section R405.4.1 Compliant Software Page
AM Ir, N..p6d. sa -, ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
1��7e7L■M1111UR1 211
FLOORS
(Total Exposed Area = 2774 sq.ft.)
#
Floor Type
Space
Perimeter R-Value Area
U-Factor
Tile
Wood Carpet
1
On Grade Depth, Tile Flr Fnsh
Office
30 ft
0
100.00 ft2
0.989
1.0
0 0
2
On Grade Depth, Tile Flr Fnsh
Cabana
23 ft
0
73.50 ft2
0.989
1.0
0 0
3
On Grade Depth, Tile Flr Fnsh
Stairs 1A
24 ft
0
127.50 ft2
0.989
1.0
0 0
4
On Grade Depth, Tile Flr Fnsh
Game
Room1
18 ft
0
321.25 ft2
0.989
1.0
0 0
5
On Grade Depth, Tile Flr Fnsh
Stairs 1 B
12 ft
0
96.00 ft2
0.989
1.0
0 0
6
On Grade Depth, Tile Flr Fnsh
AHU 1
9 ft
0
20.00 ft2
0.989
1.0
0 0
7
On Grade Depth, Tile Flr Fnsh
Game
Room2 53 ft
0
528.00 ft2
0.989
1.0
0 0
8
On Grade Depth, Tile Flr Fnsh
Study
12 ft
0
151.75 ft2
0.989
1.0
0 0
9
On Grade Depth, Tile Flr Fnsh
Family
47 ft
0
440.25 ft2
0.989
1.0
0 0
10
On Grade Depth, Tile Flr Fnsh
Kitchen
28 ft
0
427.00 ft2
0.989
1.0
0 0
11
On Grade Depth, Tile Flr Fnsh
Dining
12 ft
0
180.00 ft2
0.989
1.0
0 0
12
Flr Tuss, 18" Thkns, Tile Flr Fnsh, R-30
Ins, Ove
ClSt 3
16 ft
30
60.00 ft2
0.034
1.0
0 0
13
Flr Tuss, 18" Thkns, Tile Flr Fnsh, R-30
Ins, Ove
Bath 2
16 ft
30
55.00 ft2
0.034
1.0
0 0
14
Flr Tuss, 18" Thkns, Tile Flr Fnsh, R-30
Ins, Ove
Laundry 1
7 ft
30
68.00 ft2
0.034
1.0
0 0
sh, R-30
IFler
Ins, Ove
10
30
16
On Grade Depth, Tile Fnsh
Bath
ft
46.75 ft2
0.989
1.0
0 0
17
On Grade Depth, Tile Flr Fnsh
Pantry
0 ft
0
33.00 ft2
0.989
1.0
0 0
ROOF
Roof
Gable
Roof Rad
Solar SA
Emitt
Emitt
Deck Pitch
#
Type Materials
Area
Area
Color Barr
Absor. Tested
Tested
Insul. (deg)
1
Gable or shed RoofMetal
315 ft2
61 ft2
Light N
0.75 No
0.90
No
20 23
2
Gable or shed RoofMetal
87 ft2
17 ft2
Light N
0.75 No
0.90
No
20 23
3
Gable or shed RoofMetal
2602 ft2 500 ft2
Light N
0.75 No
0.90
No
20 23
4
Gable or shed RoofMetal
673 ft2
129 ft2
Light N
0.75 No
0.90
No
20 23
ATTIC
#
Type Ventilation
Vent Ratio (1 in)
Area RBS
IRCC
1
Full attic Unvented
0
291.00
ft2 N
N
2
Full attic Unvented
0
80.75
ft2 N
N
3
Full attic Unvented
0
2401.75ft2 N
N
4
Full attic Unvented
0
621.00 ft2 N
N
CEILING
(Total Exposed Area = 2774 sq.ft.)
#
Ceiling Type
Space
R-Value U-Factor
Area
Fraction
Truss Type
1
Attic, Metal Roof, R-20 Roof Deck In
Office
0
0.386
_Framing
100.00 ft2
0.10
Wood
2
Attic, Metal Roof, R-20 Roof Deck In
Cabana
0
0.386
73.50 ft2
0.10
Wood
3
Attic, Metal Roof, R-20 Roof Deck In
Game Room1
0
0.386
80.75 ft2
0.10
Wood
4
Attic, Metal Roof, R-20 Roof Deck In
Family
0
0.386
81.50 ft2
0.10
Wood
5
Attic, Metal Roof, R-20 Roof Deck In
Dining
0
0.386
36.00 ft2
0.10
Wood
6
Attic, Metal Roof, R-20 Roof Deck In
Clst 3
0
0.386
60.00 ft2
0.10
Wood
7
Attic, Metal Roof, R-20 Roof Deck In
Bath 2
0
0.386
55.00 ft2
0.10
Wood
8
Attic, Metal Roof, R-20 Roof Deck In
Bed 2
0
0.386
289.25 ft2
0.10
Wood
9
Attic, Metal Roof, R-20 Roof Deck In
Bed 3
0
0.386
162.00 ft2
0.10
Wood
10
Attic, Metal Roof, R-20 Roof Deck In
Master Bath
0
0.386
153.50 ft2
0.10
Wood
11
Attic, Metal Roof, R-20 Roof Deck In
Bath 4
0
0.386
49.50 ft2
0.10
Wood
12
Attic, Metal Roof, R-20 Roof Deck In
Bed 5
0
0.386
226.25 ft2
0.10
Wood
13
Attic, Metal Roof, R-20 Roof Deck In
Bed 4
0
0.386
187.50 ft2
0.10
Wood
14
Attic, Metal Roof, R-20 Roof Deck In
Laundry 2
0
0.386
55.25 ft2
0.10
Wood
15
Attic, Metal Roof, R-20 Roof Deck In
Clst 2
0
0.386
42.25 ft2
0.10
Wood
16
Attic, Metal Roof, R-20 Roof Deck In
Hall 2
0
0.386
84.00 ft2
0.10
Wood
17
Attic, Metal Roof, R-20 Roof Deck In
Lin
0
0.386
10.50 ft2
0.10
Wood
18
Attic, Metal Roof, R-20 Roof Deck In
Stairs 2B
0
0.386
93.50 ft2
0.10
Wood
19
Attic, Metal Roof, R-20 Roof Deck In
Stairs 2A
0
0.386
121.75 ft2
0.10
Wood
20
Attic, Metal Roof, R-20 Roof Deck In
Laundry 1
0
0.386
92.00 ft2
0.10
Wood
21
Attic, Metal Roof, R-20 Roof Deck In
His
0
0.386
66.50 ft2
0.10
Wood
22
Attic, Metal Roof, R-20 Roof Deck In
Master Bed
0
0.386
310.00 ft2
0.10
Wood
23
Attic, Metal Roof, R-20 Roof Deck In
Hers
0
0.386
71.25 ft2
0.10
Wood
24
Attic, Metal Roof, R-20 Roof Deck In
Master Hall
0
0.386
124.00 ft2
0.10
Wood
25
Attic, Metal Roof, R-20 Roof Deck In
Clst
0
0.386
27.50 ft2
0.10
Wood
26
Attic, Metal Roof, R-20 Roof Deck In
Bath 3
0
0.386
40.00 ft2
0.10
Wood
27
Attic, Metal Roof, R-20 Roof Deck In
Wtr Clst
0
0.386
28.00 ft2
0.10
Wood
28
Attic, Metal Roof, R-20 Roof Deck In
Pwdr Room
0
0.386
52.25 ft2
0.10
Wood
2022-Jan-17 11:11:39
wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right-EnergyOFlorida 2020 Section R405.4.1 Compliant Software Page
AM Ir, N..p6d. sa -, ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
INN L ■.Z1I1MR1011
WALLS
(Total Exposed Area = 4733 sq.ft.)
Adjacent
Cavity
Width
Height
Sheathing
U-
Frm.
Solar
Below
#
Ornt
To
Wall Type
Space
R-Value
Ft
In
Ft
In
Area
R-Value
Factor
Frac.
Absor.
Grade%
1
N
Exterior
BIk Wall, Stuc Ex
Office
9
9
6
9
4
88.3
ft2
0
0.089
0.22
0.20
0
2
S
Exterior
BIk Wall, Stuc Ex
Office
9
6
0
9
4
55.8
ft2
0
0.089
0.22
0.20
0
3
W
Exterior
Blk Wall, Stuc Ex
Office
9
10
0
9
4
93.0
ft2
0
0.089
0.22
0.20
0
4
-
Partition
Frm Wall, 1/2" Gy
Office
11
4
0
9
4
37.2
ft2
0
0.101
0.25
0.75
0
5
E
Exterior
BIk Wall, Stuc Ex
Cabana
9
9
0
9
4
83.7
ft2
0
0.089
0.22
0.20
0
6
-
Partition
Frm Wall, 1/2" Gy
Cabana
11
14
0
9
4
130.2
ft2
0
0.101
0.25
0.75
0
7
S
Exterior
BIk Wall, Stuc Ex
Stairs 1A
9
15
0
9
4
139.5
ft2
0
0.089
0.22
0.20
0
8
W
Exterior
Blk Wall, Stuc Ex
Stairs 1A
9
8
6
9
4
79.1
ft2
0
0.089
0.22
0.20
0
9
S
Exterior
BIk Wall, Stuc Ex
Game Room1
9
5
0
9
4
46.5
ft2
0
0.089
0.22
0.20
0
10
W
Exterior
BIk Wall, Stuc Ex
Game Room1
9
12
6
9
4
116.3
ft2
0
0.089
0.22
0.20
0
11
W
Exterior
BIk Wall, Stuc Ex
Stairs 1 B
9
12
0
9
4
111.6
ft2
0
0.089
0.22
0.20
0
12
N
Exterior
BIk Wall, Stuc Ex
AHU 1
9
4
0
9
4
37.2
ft2
0
0.089
0.22
0.20
0
13
W
Exterior
BIk Wall, Stuc Ex
AHU 1
9
5
0
9
4
46.5
ft2
0
0.089
0.22
0.20
0
14
N
Exterior
Blk Wall, Stuc Ex
Game Room2
9
36
6
9
4
339.5
ft2
0
0.089
0.22
0.20
0
15
E
Exterior
BIk Wall, Stuc Ex
Game Room2
9
16
0
9
4
148.8
ft2
0
0.089
0.22
0.20
0
16
E
Exterior
BIk Wall, Stuc Ex
Study
9
12
0
9
4
111.6
ft2
0
0.089
0.22
0.20
0
17
E
Exterior
BIk Wall, Stuc Ex
Family
9
17
6
9
4
162.8
ft2
0
0.089
0.22
0.20
0
18
W
Exterior
BIk Wall Stuc Ex
Family
9
15
0
9
4
139.5
ft2
0
0.089
0.22
0.20
0
19
-
Partition
Frm Wall, 1/2" Gy
Family
11
14
0
9
4
130.2
ft2
0
0.101
0.25
0.75
0
20
N
Exterior
BIk Wall, Stuc Ex
Kitchen
9
4
0
9
4
37.2
ft2
0
0.089
0.22
0.20
0
21
E
Exterior
BIk Wall, Stuc Ex
Kitchen
9
19
6
9
4
181.4
ft2
0
0.089
0.22
0.20
0
22
S
Exterior
BIk Wall, Stuc Ex
Kitchen
9
4
0
9
4
37.2
ft2
0
0.089
0.22
0.20
0
23
W
Exterior
BIk Wall, Stuc Ex
Dinincl
9
12
0
9
4
111.6
ft2
0
0.089
0.22
0.20
0
24
N
Exterior
Blk Wall, Stuc Ex
Clst 3
9
10
0
9
0
90.0
ft2
0
0.089
0.22
0.20
0
25
E
Exterior
BIk Wall, Stuc Ex
Clst 3
9
6
0
9
0
54.0
ft2
0
0.089
0.22
0.20
0
26
E
Exterior
BIk Wall, Stuc Ex
Bath 2
9
5
6
9
0
49.5
ft2
0
0.089
0.22
0.20
0
27
S
Exterior
BIk Wall, Stuc Ex
Bath 2
9
10
0
9
0
90.0
ft2
0
0.089
0.22
0.20
0
28
N
Exterior
BIk Wall, Stuc Ex
Bed 2
9
19
6
9
0
175.5
ft2
0
0.089
0.22
0.20
0
29
E
Exterior
Blk Wall, Stuc Ex
Bed 2
9
4
0
9
0
36.0
ft2
0
0.089
0.22
0.20
0
30
E
Exterior
BIk Wall, Stuc Ex
Bed 3
9
12
0
9
0
108.0
ft2
0
0.089
0.22
0.20
0
31
N
Exterior
BIk Wall, Stuc Ex
Master Bath
9
4
0
9
0
36.0
ft2
0
0.089
0.22
0.20
0
32
E
Exterior
BIk Wall, Stuc Ex
Master Bath
9
8
0
9
0
72.0
ft2
0
0.089
0.22
0.20
0
33
N
Exterior
BIk Wall, Stuc Ex
Bath 4
9
3
6
9
0
31.5
ft2
0
0.089
0.22
0.20
0
34
S
Exterior
BIk Wall, Stuc Ex
Bath 4
9
3
6
9
0
31.5
ft2
0
0.089
0.22
0.20
0
35
W
Exterior
Blk Wall, Stuc Ex
Bath 4
9
5
6
9
0
49.5
ft2
0
0.089
0.22
0.20
0
36
W
Exterior
BIk Wall, Stuc Ex
Bed 5
9
13
0
9
0
117.0
ft2
0
0.089
0.22
0.20
0
37
W
Exterior
BIk Wall, Stuc Ex
Bed 4
9
6
0
9
0
54.0
ft2
0
0.089
0.22
0.20
0
38
N
Exterior
BIk Wall, Stuc Ex
Hall 2
9
21
0
9
0
189.0
ft2
0
0.089
0.22
0.20
0
39
W
Exterior
BIk Wall, Stuc Ex
Hall 2
9
4
0
9
0
36.0
ft2
0
0.089
0.22
0.20
0
40
S
Exterior
Blk Wall, Stuc Ex
Stairs 2B
9
8
0
9
0
72.0
ft2
0
0.089
0.22
0.20
0
41
W
Exterior
BIk Wall, Stuc Ex
Stairs 2B
9
13
0
9
0
117.0
ft2
0
0.089
0.22
0.20
0
42
N
Exterior
BIk Wall, Stuc Ex
Stairs 2A
9
3
0
9
0
27.0
ft2
0
0.089
0.22
0.20
0
43
S
Exterior
BIk Wall, Stuc Ex
Stairs 2A
9
6
6
9
0
58.5
ft2
0
0.089
0.22
0.20
0
44
W
Exterior
BIk Wall, Stuc Ex
Stairs 2A
9
8
6
9
0
76.5
ft2
0
0.089
0.22
0.20
0
45
S
Exterior
Blk Wall, Stuc Ex
Laundry 1
9
2
0
9
0
18.0
ft2
0
0.089
0.22
0.20
0
46
W
Exterior
BIk Wall, Stuc Ex
Laundry 1
9
8
0
9
0
72.0
ft2
0
0.089
0.22
0.20
0
47
S
Exterior
BIk Wall, Stuc Ex
His
9
9
6
9
0
85.5
ft2
0
0.089
0.22
0.20
0
48
W
Exterior
BIk Wall, Stuc Ex
His
9
7
0
9
0
63.0
ft2
0
0.089
0.22
0.20
0
49
E
Exterior
BIk Wall, Stuc Ex
Master Bed
9
17
6
9
0
157.5
ft2
0
0.089
0.22
0.20
0
50
S
Exterior
Blk Wall, Stuc Ex
Master Bed
9
17
6
9
0
157.5
ft2
0
0.089
0.22
0.20
0
51
E
Exterior
BIk Wall, Stuc Ex
Bath 3
9
5
0
9
0
45.0
ft2
0
0.089
0.22
0.20
0
52
E
Exterior
BIk Wall, Stuc Ex
Wtr Clst
9
7
0
9
0
63.0
ft2
0
0.089
0.22
0.20
0
53
S
Exterior
BIk Wall, Stuc Ex
Wtr Clst
9
4
0
9
0
36.0
ft2
0
0.089
0.22
0.20
0
DOORS
(Total Exposed Area = 68 sq.ft.)
Width
Height
#
Ornt
Door Type
Space
Storms
U-Value
Ft In
Ft In
Area
1
E
Fbrgls Door
Cabana
None
0.127
2 6
8 0
20.0 ft2
2
N
Fbrgls Door
Game Room2
None
0.127
3 0
8 0
24.0 ft2
3
W
Fbrgls Door
Family
None
0.127
3 0
8 0
24.0 ft2
2022-Jan-17 11:11:39
wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right-EnergyOFlorida 2020 Section R405.4.1 Compliant Software Page
AM Ir, N..p6d. sa -, ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
INN L■.Z1-111MM H
WINDOWS
(Total Exposed Area = 640 sq.ft.)
Wall
Overhang
Interior
#
Ornt
ID
Frame Panes NFRC
U-Factor
SHGC
Impact W x H, Area
Depth
Separation
Shade
Screening
1
W
3
Metal Low-E Double Yes
0.310
0.19
Yes 3'0" x 5'2" , 16
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
2
W
8
Metal Low-E Double Yes
0.280
0.17
Yes 2'5" x 4'1" , 10
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
3
W
10
Metal Low-E Double Yes
0.310
0.19
Yes 9'1" x 6'3" , 57
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
4
N
14
Metal Low-E Double Yes
0.310
0.19
Yes 9'0" x 5'2" , 47
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
5
E
15
Metal Low-E Double Yes
0.310
0.20
Yes 6'0" x 8'0" , 48
ft2
10 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
6
E
16
Metal Low-E Double Yes
0.310
0.19
Yes 6'1" x 5'2" , 31
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
7
E
17
Metal Low-E Double Yes
0.310
0.20
Yes 12'0" x 8'0" , 96
ft2
12 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
8
W
18
Metal Low-E Double Yes
0.310
0.19
Yes 6'0" x 6'1" , 37
ft2
9 ft 4 in
1 ft 0 in
Blinds 45'
outdoor
9
N
20
Metal Low-E Double Yes
0.260
0.24
Yes 1'0" x 4'2" , 4
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
10
E
21
Metal Low-E Double Yes
0.310
0.19
Yes 4'5" x 4'2" , 18
ft2
9 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
11
S
22
Metal Low-E Double Yes
0.260
0.24
Yes 1'0" x 4'2" , 4
ft2
12 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
12
W
23
Metal Low-E Double Yes
0.310
0.19
Yes 6'1" x 6'3" , 38
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
13
S
27
Metal Low-E Double Yes
0.270
0.18
Yes 3'0" x 1'5" 4
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
14
N
28
Metal Low-E Double Yes
0.310
0.19
Yes 6'0" x 5'2" , 31
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
15
E
30
Metal Low-E Double Yes
0.310
0.19
Yes 6'1" x 5'2" , 31
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
16
E
32
Metal Low-E Double Yes
0.260
0.22
Yes 0'10" x 3'4" , 3
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
17
W
35
Metal Low-E Double Yes
0.320
0.19
Yes 2'0" x 5'2" , 10
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
18
W
36
Metal Low-E Double Yes
0.310
0.19
Yes 6'0" x 5'2" , 31
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
19
W
37
Metal Low-E Double Yes
0.320
0.19
Yes 5'0" x 4'2" , 21
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
20
N
38
Metal Low-E Double Yes
0.280
0.17
Yes 2'5" x 4'0" , 10
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
21
W
39
Metal Low-E Double Yes
0.320
0.19
Yes 2'6" x 4'0" , 10
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
22
W
41
Metal Low-E Double Yes
0.280
0.17
Yes 2'6" x 4'0" , 10
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
23
W
44
Metal Low-E Double Yes
0.280
0.17
Yes 2'5" x 4'1" , 10
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
24
W
46
Metal Low-E Double Yes
0.320
0.19
Yes 5'0" x 3'2" , 16
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
25
E
49
Metal Low-E Double Yes
0.310
0.19
Yes 6'2" x 27' , 16
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
26
S
50
Metal Low-E Double Yes
0.260
0.24
Yes 6'0" x 1'4" , 8
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
27
S
50
Metal Low-E Double Yes
0.310
0.19
Yes 3'0" x 5'2" , 16
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
28
E
51
Metal Low-E Double Yes
0.320
0.19
Yes 2'0" x 2'0" , 4
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
29
E
52
Metal Low-E Double Yes
0.320
0.19
Yes 2'0" x 2'0" 4
ft2
2 ft 0 in
1 ft 0 in
Blinds 45'
outdoor
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
0
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA E LA
ACH
ACH 50
1
Wholehouse
Blower Door 0.000408
5283
290.6 545.7
0.65
7.00
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric strip
AFUE: 100.0
16.4 kBtu/hr
1
sys#1
2
Split air source heat pump
HSPF: 9.1
12.3 kBtu/hr
2
sys#2
3
Electric stri
AFUE: 100.0
24.1 kBtu/hr
3
s s#3
COOLING SYSTEM
#
System TVpe
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Split air conditioner
SEER: 16.0 24.0
kBtu/hr 800 cfm 0.72 1
sys#1
2
Split air source heat pump
SEER: 18.0 12.4
kBtu/hr 413 cfm 0.70 2
sys#2
3
Split air conditioner
SEER: 16.0 29.0 kBtu/hr 967 cfm 0.71
3
s s#3
HOT WATER SYSTEM
#
System Type Subtype Location
EF
Cap Use
SetPnt
Conservation
1
Electric
conventional
1.96 UEF
80 gal 90 gal
120 T
None
2
Electric conventional
1.96 LIE 80 al 90 al
120 T
None
DUCTS
---------
Supply --------- ---------
Return ---------
Air
CFM 25 Percent
HVAC #
#
Location
R-Value Area Location
Area
Leakage Type Handler
Out Leakage ON RLF Heat Cool
1
Zone
2 Attic
6.0 232 ft2 Zone 2 Attic
67 ft2
Default Leakage Uncond
(Default)
6.00 0.08
1 1
2
Zone
1 Attic
6.0 171 ft2 Zone 1 Attic
8 ft2
Default Leakage Zone 1
Default
6.00 0.08
2 2
3
Zone 3 Attic
6.0 439 ft2 Zone 3 Attic
60 ft2
Default Leakage Zone 3 Attic
Default
6.00 0.08
3 3
2022-Jan-17 11:11:39
wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 6
AM Ir, N..p6d. sa -, ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
INN L ■.ZIIMWI&H
TEMPERATURES
Programmable Thermostat: Y
Ceiling Fans:
Cooling [ X ]Jan
[ X] Feb
[ X] Mar
[ X] Apr
[ X] May [ X] Jun
[ X] Jul
[ X] Aug
[ X] Sep
[ X] Oct
[ X] Nov
[ X] Dec
Heating [ X ]Jan
[ X] Feb
[ X] Mar
[ X] Apr
[ X] May [ X] Jun
[ X] Jul
[ X] Aug
[ X] Sep
[ X] Oct
[ X] Nov
[ X] Dec
Venting [ X ]Jan
[ X] Feb
[ X] Mar
[ X] Apr
[ X] May [ X] Jun
[ X] Jul
[ X] Aug
[ X] Sep
[ X] Oct
[ X] Nov
[ X] Dec
Thermostat Schedule:
Florida
Building Code, 7th Edition
Hours
Schedule Type
1
2
3 4 5
6
7
8
9 10
11
12
Cooling (WD)
AM
75
75
75 75 75
75
75
75
75 75
75
75
PM
75
75
75 75 75
75
75
75
75 75
75
75
Cooling (WEH)
AM
75
75
75 75 75
75
75
75
75 75
75
75
PM
75
75
75 75 75
75
75
75
75 75
75
75
Heating (WD)
AM
72
72
72 72 72
72
72
72
72 72
72
72
PM
72
72
72 72 72
72
72
72
72 72
72
72
Heating (WEH)
AM
72
72
72 72 72
72
72
72
72 72
72
72
PM
72
72
72 72 72
72
72
72
72 72
72
72
2022-Jan-17 11:11:39
wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 7
...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX = 84
The lower the EnergyPerformance Index, the more efficient the home.
1. New home or addition
1. New (From
Plans)
12. Ducts, location & insulation level
a. Supply ducts:
R
6.0
2. Single-family or multiple -family
2. Single
-Family
b. Return ducts:
R
6.0
c. AHU location:
Zone 1,Uncond,Zone 3 Attic
3. Number of units, if multiple -family
3.
1
13. Cooling systems
Capacity
65.4
4. Number of bedrooms
4.
6
a. Split system:
SEER
16.00
b. Single package:
SEER
5. Is this a worst case? (yes/no)
5.
Yes
c. Ground/water source: SEER/COP
d. Room unit/PTAC:
EER
6. Conditioned floor area (ft2)
6.
4946.75
e. Other:
7. Windows, type and area*
14. Heating systems
Capacity
52.7
a. U-Factor:
Db7drnpact(Avq), 0.307
a. Split system heat pump:
HSPF
9.10
b. Solar Heat Gain Coefficient (SHGC):
7b.
0.19
b. Single package heat pump:
HSPF
c. Area (ft2)
7c.
640
c. Electric resistance:
COP
100.00
d. Gas furnace, natural gas:
AFUE
8. Skylights
e. Gas furnace, LPG:
AFUE
a. U-Factor:
8a.
f. Other:
b. Solar Heat Gain Coefficient (SHGC):
8b.
15. Water heating systems
9. Floor type, insulation level
a. Electric resistance:
1.96 UEF
a. Slab -on -grade (R-value):
9a.
0.0
b. Gas fired, natrual gas:
b. Wood, raised (R-value):
9b.
30.0
c. Gas fired, LPG:
c. Concrete, raised (R-value)
9c.
d. Solar system with tank:
e. Dedicated heat pump with tank:
10 Wall type and insulation:
f. Heat recovery unit:
HeatRec%
a. Exterior:
g. Other:
1. Wood frame (Insulation R-value):
10a1.
2. Masonry (Insulation R-value):
10a2.
9
16. HVAC credits claimed (Performance Method)
b. Adjacent:
a. Ceiling fans:
1. Wood frame (Insulation R-value):
10b1.
11
b. Cross ventilation:
2. Masonry (Insulation R-value):
10b2.
c. Whole house fan:
d. Multizone cooling credit:
Yes
11. Ceiling type and insulation level
e. Multizone heating credit:
Yes
a. Under attic (R-value):
1 la.
0.0
f. Programmable thermostat:
Yes
b. Single assembly (R-value):
11 b.
c. Knee walls/skylight walls (R-value)
11c.
d. Radiant barrier installed
11d.
*Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features
which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
DocuSigned by:
Ce:)6LL
Builder Signatu 9A,6" Gya'�a, Date: 111712022
5A96BDBAD32842B...
Address of New Home: TBD Ulrich Road
City/FL Zip: Fort Pierce, FL 34982
2022-Jan-17 11:11:39
wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software page 8
...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
FORM R405-2020
Florida Building Code, Energy Conservation, 7th Edition (2020)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: TBD Ulrich Road PERMIT #:
Fort Pierce, FL 34982
MANDATORY REQUIREMENTS - See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statues) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. completed and signed by the builder The building official shall verify that the EPL display card accurately reflects the plans
and specifications submitted to demonstrate compliance for the building. A copy of the EPL display card can be found in Appendix RD.
SECTION R402 BUILDING THERMAL ENVELOP
R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
El R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing
methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
w ith the manufacturer's instructions and the criteria listed in Table 402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall inspect all components and verify compliance.
ElR402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended
weatherstripping or other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond
intended infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeledin accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight-figging doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
ElR402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
2022-Jan-17 11:11:39
wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 9
...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
FORM R405-2020
MANDATORY REQUIREMENTS -(Continued)
❑ R402.4.4 Rooms containing fuel -burning appliances In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent apliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
❑ R403.1 Controls
El R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.3.2 Sealing (Mandatory). All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7),
Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
rl R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design air flow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
2. Post construction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test.
Exceptions:
1. A duct leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is required
for Section R405 compliance where credit is taken for leakage, and a duct air leakage Qn to the outside of less
than 0.080 (where Qn = duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals)
is indicated in the compliance report for the proposed design.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑ R403.3.5 Building Cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C)
or below 55°F (13°C) shall be insulated to a minimum of R-3.
❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance, and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace termperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
El R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe
shall be dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for how water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
2022-Jan-17 11:11:39
wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 10
...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
FORM R405-2020
MANDATORY REQUIREMENTS -(Continued)
R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat
traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as
possible to the storage tank.
❑ R403.5.6 Water heater efficiencies (Mandatory).
El R403.5.6.1 Storage water heater temperature controls.
R403.5.6.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 140oF (38°C to 60oC).
❑ R403.5.6.1.2 shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
❑ R403.5.6.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment
installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the
appropriate water heating category. Solar water heaters shall met the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water heating system. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida
Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation, including:
Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the
ventilation system is not operating.
El R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by
an electronically commutated motor.
❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure of for mechanical
ventilation shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed spaces(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19, space permitting, or R-10 otherwise.
❑ R403.7 Heating and cooling equipment.
R403.7.1 Equipment sizing (Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved methodologies, heating and cooling calculation
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
CFM
MINIMUM EFFICACY (a)
CFM/WATT
AIRFLOW RATE MAXIMUM
CFM
HRV or ERV
Any
1.2 cfm/watt
Any
Range hoods
Any
2.8 cfm/watt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
< 90
Bathroom, utility room
90
2.8 cfm/watt
Any
For SI: 1 cfm - 28.3 L/min.
(a) When tested in accordance HVI Standard 916
2022-Jan-17 11:11:39
wriglhtsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 11
...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
MANDATORY REQUIREMENTS -(Continued)
❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is
less than the calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the
capacity of equipment may be sized in accordance with good design practice.
❑ R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1
El R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system controls (Mandatory). Snow- and ice -melting systems, supplied through energy service to the building,
shall include automatic controls capable of shutting off the system hen the pavement temperature is above 50°F (10°C), and no
precipitation is falling and an automatic or manual control that w ill allow shutoff w hen the outdoor temperature is above 40°F (4.8°C).
R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
rl R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
El R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operations.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor- retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
❑ R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
2022-Jan-17 11:11:39
wrigihtsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 12
...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
MANDATORY REQUIREMENTS - (Continued)
❑ R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
0 R403.11 Portable spas (Mandatory). The energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
❑ R403.13 Dehumidifiers (Mandatory) If installed, a dehumidifier shall conform to the following requirements:
1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/ kWh if the total dehumidifier capacity for the house
is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day.
2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air.
3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2.
4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code, Residential.
❑ R403.13.1 Ducted dehumidifiers Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13,
conform to the following requirements:
1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft
damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct.
2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system,
a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct.
3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the
central cooling evaporator coil.
4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
❑ R404.1 Lighting equipment (Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an
efficacy of at least 45 lumens -per -watt or shall utilize lamps with an efficacy of not less than 65 lumens -per -watt.
Exception: Low -voltage lighting.
❑ R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
2022-Jan-17 11:11:39
wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 13
...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
FORM R405-2020
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Roe Residence Builder Name Groza Builders, Inc
Street: TBD Ulrich Road Permit Office:
City, State, Zip: Fort Pierce, FL 34982 Permit Number:
Owner: Roe Residence Jurisdiction: St. Lucie
Design Location: FL, St Lucie Cc Intl
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the
requirements
building envelope. The exterior thermal envelope
Air -permeable insulation shall not be used as a
pp
El4
contains a continuous barrier. Breaks orjoints in the
g e
air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit
The insulation in any dropped ceiling/soffit
shall be aligned with the insulation and any
shall be aligned with the air barrier.
gaps in the air barrier shall be sealed.
❑
Access openings, drop down stairs or knee wall doors
to unconditioned attics paces shall be sealed.
Walls
The junction of the foundation and sill plate
Cavities with corners and headers of frame walls
shall be sealed.The junction of the top plate
shall be insulated by completely filling the cavity
and the top of exterior walls shall be sealed.
with a material having a thermal resistance of R-3
❑
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier
Windows, skylights
The space between window/doorjambs and framing,
framing
❑
and doors
and skylights and shall be sealed.
Rim joists are insulated and include an air
Rim joists shall be insulated.
❑
Rim joists
barrier.
Floors (including
The air barrier shall be installed at any exposed
Floor framing cavity Insulation shall be installed
above -garage and
edge of insulation.
to maintain permanent contact with the underside
cantilevered floors)
of subfloor decking, or floor framing cavity
insulation shall be permitted to be in contact
❑
with the top sideof sheathing, or continuous
insulation installed on the underside of floor
framing and extends from the bottom to the top of
all perimeter floor framing members.
Crawl space
Exposed earth in unvented crawl spaces shall be
Where provided in lieu of floor insulation,
walls
covered with a Class I vapor retarder with
insulation shall be permanently attached
❑
overlapping joints taped.
to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft
openings to exterior or unconditioned space shall
❑
be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or
narrow cavities shall be filled by insulation that
❑
on installation readily conforms to the available
cavity spaces.
Garage
Air sealing shall be provided between the garage
❑
separation
and conditioned spaces.
Recessed
Recessed light fixtures installed in the building
Recessed light fixtures installed in the
lighting
thermal envelope shall be sealed to the finished surface.
building thermal envelope shall be air tight
❑
and IC rated.
Plumbing and
Batt insulation shall be cut neatly to fit around
wiring
wiring and plumbing in exterior walls, or
insulation that on installation readily conforms
❑
to available space shall extend behind piping
and wiring.
Shower/tub on
The air barrier shall be installed behind
Exterior walls adjacent to showers and tubs
exterior wall
electrical or communication boxes or air -sealed
shall be insulated.
❑
boxes shall be installed.
Electrical/phone
The air barrier shall be installed behind
box on exterior
electrical or communication boxes or air -sealed
❑
walls
boxes shall be installed.
HVAC register
HVAC supply and return register boots that penetrate
boots
building thermal envelope shall be sealed to the
❑
subfloor, wall covering or ceiling penetrated by the boot.
Concealed
When required to be sealed, concealed fire
sprinklers
sprinklers shall only be sealed in a manner that
is recommended by the manufacturer.
❑
Caulking or other adhesive sealants shall not be
used to fill voids between fire sprinkler cover
plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
Ri h 2022-Jan-1711:11:39
wrlghtSof# g t-Suite® Universal 2021 21.0.11 RSU29066 Right -Energy® Florida 2020 Section R405.4.1 Compliant Software Page 14
AN W. Nw.�: . , ...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
FORM R405-2020
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation, 7th Edition
Jurisdiction: St. Lucie
Permit Number:
Job Information
Builder: Groza Builders, Inc Community: Lot:
Address: TBD Ulrich Road Unit:
City: Fort Pierce State: FL Zip: 34982
Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method.
❑ PRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding
7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2.
building or dwelling unit shall be tested and verified as having an air leakage rate of not
❑The
PERFORMANCE or ERI METHOD exceeding the selected ACH(50) value, as shown on FORM R405-2020 (Performance) or
R406-2020 (ERI), section labeled as Infiltration, sub -section ACH50.
ACH(50) specified on Form R405-2020-Energy Calc (Performance) or R406-2020 (ERI): 7.000
x60 _ 45284 =_ Method for calculating building volume:
_
CFM(50) Building Volume ACH(50) ❑ Retrieved from architectural plans
❑ PASS E Code software calculated
El Field measured and calculated
❑ When ACH(50) is less than 3, Mechanical Ventilation installation
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.
(50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues, or individuals
licensed as set forth in Section 489.105(3)(f), (g), or (i) or and approved third party. A written report of the results of the test shall be
signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
2022-Jan-17 11:11:39
wrightsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software Page 15
...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
FORM R405-2020
Duct Leakage Test Report
Residential Perscriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation, 7th Edition
Jurisdiction: St. Lucie
Job Information
Permit Number:
Builder: Groza Builders, Inc Community: Lot:
Address: TBD Ulrich Road Unit:
City: Fort Pierce State: FL Zip: 34982
Duct Leakage Test Results
System 1
cfm25
System 2
cfm25
System 3
cfm25
Sum of any
additional systems
cfm25
Total of all
systems
cfm25
4947 = _ On
Total of all Total Conditioned
systems Square Footage
❑ PASS ❑ FAIL
❑ Prescriptive Method cfm25 (Total)
To qualify as "substantially leak free" Qn Total must be less
than or equal to 0.04 if air handler unit is installed. If air handler
unit is not installed, Qn Total must be less than or equal to
0.03. This testing method meets the requirements in
accordance with Section R403.3.3.
Is the air handler unit installed ❑ YES(- 0.04 Qn)
during testing? ❑ NO (< 0.03Qn)
❑ Performance / ERI Method cfm25 (Out or Total)
To qualify using this method, Qn must be not greater than the
proposed duct leakage Qn specified on Form R405-2020 or
R406-2020.
Leakage Type selected on Form Qn specified on Form R405-2020
R405-2020 (Energy Calc) or R406-2020 (Energy Calc) or R406-2020
Default Leakage 0.08
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set
forth in Section 489.105(3)(f), (g) or (i), Florida Statues.
Testing Company
Company Name:
Phone:
I hereby verify that the above duct leakage test results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #:
Issuing Authority:
2022-Jan-17 11:11:39
wrlghtsoft' Right -Suite@ Universal 2021 21.0.11 RSU29066 Right -Energy@ Florida 2020 Section R405.4.1 Compliant Software page 16
...cuments\Wrightsoft HVAC\TBD Ulrich Road GBI.rup Calc = MJ8 Front Door faces: N
DocuSign Envelope ID: 75BE8AAB-059B-4EDF-8E45-912991790B4B
Reference Home Characteristics
Roe Residence Title: TBD Ulrich Road GBI
TBD Ulrich Road
Fort Pierce, FL 34982 FLBase202O
Above -grade Walls (Uo)
0.084
Above -grade Wall Solar Absorptance
0.75
Above -grade Wall Infared Emittance
0.90
Basement Walls (Uo)
n/a
Above -grade Floors (Uo)
n/a
Slab Insulation R-Value
0.0
Ceilings (Uo)
0.030
Roof Solar Absorptance
0.75
Roof Infared Emittance
0.90
Attic Vent Area (ft2)
0.97
Crawls pace Vent Area (ft2)
n/a
Exposed Masonry Floor Area (ft2)
633.20
Carpet & Pad R-Value
2.0
Door Area (ft2)
0.00
Door U-Factor
n/a
North Window Area (ft2)
102.30
South Window Area (ft2)
154.10
East Window Area (ft2)
154.10
West Window Area (ft2)
154.10
Window U-Factor
0.400
Window SHGC (Heating)
0.2169
Window SHGC (Cooling)
0.2169
ACH50
7.00
Internal Gains * (Btu/day)
196057
Water heater gallons per day
270.00
Water Heater set point temperature
120.00
Water heater efficiency rating
2.59
Labeled Heating System Rating and Efficiency
HSPF = 8.2
Labeled Cooling System Rating and Efficiency
SEER = 14.0
Air Distribution System Efficiency
0.88
Thermostat Type
Manual
Heating Thermostat Settings
72.0 (All hours)
TMY City: FL -Fort -Pierce