Loading...
HomeMy WebLinkAboutREVISED,FL ENERGY EFFICIENC CODE .I FORM R405-2020 qP,p 2, zp2 FLORIDA ENERGYI'EFFICIENCY CODLt�� ,PUILDING CONSTRUCTION Florida Department of Business and Professional Regulat cSi �`2esidential Performance Method. Project Name: Ravina 3A Builder Name: Street: Garage Left Permit Office: City,State,Zip: Port St.Lucie,FL I Permit Number: Owner. Ravinia 3A-Left Hand Garage Jurisdiction: Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2) ,I 1. New construction or existing New(From Plans) 10. Wall Type41328.0 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1168.00 ft2 b.Frame-Wood,Adjacent R=13.0 160.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3, d.N/A R= ft2 5. Is this a worst case? Yes 11.Ceiling Types (1450.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1450.00 ft2 6. Conditioned floor area above grade(ftl) 1450 b.N/A R= ftZ . Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 , 7. Windows(126.0 sqft.) Description,I Area 12.Ducts R ft2 i a.Sup:Attic,Ret:Foyer,AH:Foyer 6 75 a: U-Factor: Sgl,U=0.39 ; 126.00 ft2 SHGC: SHGC=0.29 b:i U-Factor: N/A ft2 13.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 28.6 SEER:14.50 c.: U-Factor: N/A j ft2 SHGC: 14 Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 1.417 ft. . Area Weighted Average SHGC: 0.290 a.Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15.Hot water systems SHGC(AVG): N/A a.Electric Cap:50 gallons 9. Floor Types (1450.0 sqft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1450.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A j R= ft2 16.Credits CF i Total Proposed Modified Loads: 45.06 PASS Glass/Floor Area: 0.087 Total Baseline Loads: 46.17 e� I hereby certify that the plans and specifications covered by Review of the plans and o� C11t;ST�7 , this calculation are in compliance with)the Florida Energy specifications covered by this Code. calculation indicates compliance ,� ; r' �,`a with the Florida Energy Code. qa `'"�tPREPARED BY: Before construction is completed DATE: 4-6-2022 this building will be inspected for I : compliance with Section 553.908 it x r i I hereby certify that this building,as designed, is in compliance �: r 3` •Jr, e Florida Statutes. with the Florida Energy �•a '?.,�f Code. ^c O D w1rv; OWNER/AGENT: DA BUILDING OFFICIAL: sy. � TE:. y -CR-7. I l DATE: I - Compliance requires certificatio Inl by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. J -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). - Proposed Qn of 0.080 exceeds the performance method default limit of 0.08 and therefore does not require duct testing. IZ405 .2.3 4/5/2022 9:42 PM Energyl�Gauge@)USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 6 i� i II ' I 1 P W I FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Ravina 3A Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1450 Lot# Owner Name: Ravinia 3A-LeftlHand Garag Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 180 Street: Garage Left Permit Office: ! Cross Ventilation: No County: St.Lucie Jurisdiction: ! Whole House Fan: No City,State,Zip: Port St.Lucie, ,Family Type: Detached j FL, New/Existing: New(From Plans) Comment: CLIMATE r Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL LVERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume ' �I! 1 Entire House ! 1450 11600 SPACES Number Name i Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M Bedroom V 195 1560 No 2 1 1 Yes Yes Yes 2 M WIC ( 48 384 No 0 1 No Yes Yes 3 M Bath 84 672 No 1 1 Yes Yes Yes 4 Bedroom 3 ! 143 1144 No 1 1 1 Yes Yes Yes 5 Bath 2 f 54 432 No 0 1 Yes Yes Yes 6 Bedroom 2 143 1144 No 1 1 1 Yes Yes Yes 7 Great Room 232 1856 No 2 1 Yes Yes des 8 Dining 128 1024 No -2 1 Yes Yes Yes i 9 Kitchen 202 1616 Yes 2 1 Yes Yes Yes 10 Foyer l 85 680 No 1 1 Yes Yes Yes 11 Hall III 35 280 No 0 1 No Yes Yes i 12 Laundry 77 616 No 0 1 Yes Yes Yes 13 Hall 24 192 No 0 1 No Yes Yes 5 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio M Bedroom 32 ft 195 ftz 1 0 1 2 Slab-On-Grade Edge Insulatio M WIC 1 ft 48 ftZ ____ 1 0 0 3 Slab-On-Grade Edge Insulatio M Bath E ft 84 ftz ____ 1 0 4SIab-On-Grade Edge Insulatio Bedroom 3 11 ft 143 ftZ ---- 1 0 0 i 4/5/2022 9:42 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 6 4 i I FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT I FLOORS # Floor Type IL.! Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood' Carpet 5 Slab-On-Grade Edge Insulatio Bath 2 6 ft 54 ft2 ____ 1 0 0; 6 Slab-On-Grade Edge Insulatio Bedroom 2 11 ft 143 ft2 ____ 1 0 0� 7Slab-On-Grade Edge Insult do Great Room 30 ft 232 ft2 ____ 1 0 0, 'I� I 8 Slab-On-Grade Edge Insulatio Dining 8 ft 128 ft2 ____ 1 0 0; 9 Slab-On-Grade Edge Insuilatio Kitchen 12 ft 202 ft2 ____ 1 0 Q 10SIab-On-Grade Edge Insulatio Foyer 19 ft 85 ft2 ____ 1 0 0 11SIab-On-Grade Edge Ins ulatio Hall 1 1 ft 35 ft2 ____ 1 0 0 12SIab On-Grade Edge Insulatio Laundry 11 ft 77 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulatio Hall 2 1 ft 24 ft2 ____ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck q Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1571 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 22.62 ATTIC d V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1450 ft2 N N �l CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented); M Bedroom 30 Batt 195 ft2 0.1 Wood 2 Under Attic(Vented) M WIC 30 Batt 48 ft2 0.1 Wood 3 Under Attic(Vented): M Bath 30 Batt 84 ft2 0.1 Wood 4 Under Attic(Vented); Bedroom 3 30 Batt 143 ft2 0.1 Wood 5 Under Attic(Vented), Bath 2 30 Batt 54 ft2 0.1 Wood 6 Under Attic(Vented)f Bedroom 2 30 Batt 143 ft2 0.1 Wood 7 Under Attic(Vented) Great Room 30 Batt 232 ft2 0.1 Wood ,a 8 Under Attic(Vented)' Dining 30 Batt 128 ft2 0.1 Wood 9 Under Attic(Vented); Kitchen 30 Batt 202 ft2 0.1 Wood 10 Under Attic(Vented): Foyer 30 Batt 85 ft2 0.1 Wood 11 Under Attic(Vented); Hall 1 30 Batt 35 ft2 0.1 Wood i 12 Under Attic(Vented)I Laundry 30 Batt 77 ft2 0.1 Wood i 13 Under Attic(Vented)! Hall 2 30 Batt 24 ft2 0.1 Wood i i 4/5/2022 9:42 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 6 i ' II -FORM R405-2020 I;INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent j j S ace Cavity Width Height Sheathing Framing Solar' 13 to w P 1 N=>S Exterior Concrete Block-Int InsJA Bedroom 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 2 W=>E Exterior Concrete Block-Int InsuM Bedroom 4.1 18 0 8 0 144.0 ft2 0 0 0.4, 0 3 W=>E Exterior Concretes iBlock-Int Insul M Bath 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 4 W=>E Exterior ConcretelBlock-Int InsuBedroom 3 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 5 W=>E Exterior Concrete 1Block-Int Insul Bath 2 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 6 W=>E Exterior Concrete Block-Int InsuBedroom 2 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 7 N=>S Exterior Concrete Block-Int InsL(Breat Room 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 8 E=>W Exterior Concrete Block-Int InsL(Great Room 4.1 14 0 8 0 112.0 ft2 0 0 0.4 { 0 9 E=>W Exterior Concrete1Block-Int Insul Dining 4.1 8 0 8 0 64.0 ft2 0 0 0.4 1 0 li 10 E=>W Exterior Concrete Block-Int Insul Kitchen 4.1 12 0 8 0 96.0 ft2 0 0 0.4 0 _11 E=>W Exterior Concrete Block-Int Insul Foyer 4.1 8 0 8 0 64.0 ft2 0 0 0.4 i 0 12 S=>N Exterior Concrete Block-Int Insul Foyer 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 13 W=>E Exterior Concrete'Block-Int Insul Foyer 4.1 1 0 8 0 8.0 ft2 0 0 0.4 + 0 14 E=>W Exterior Concrete Block-Int Insul Laundry 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 15 N=>S Garage Frame-IlWood Laundry 13 7 8 56.0 ft2 0.23 0.4 0 16 N=>S Garage Frame-Wood Bedroom 2 13 13 8 104.0 ft2 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area j Ft In Ft In 1 S=>N Insulated Foyer None .39 3 6 10 20.5 ftZ 2 N=>S Insulated Laundry None .39 2 8 6 8 17.8 ft2 II C WINDOWS ;Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame CPanes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>S 1 Vinyl Low?E Single Yes 0.39 0.29 Y 20.0 ft2 1 ft 5 in 1 ft 4 in None None 2 W=>E 4 Vinyl LowE Single Yes 0.39 0.29 Y 15.0 ft2 1 ft 5 in 1 ft 4 in None None 3 W=>E 6 Vinyl Low1E Single Yes 0.39 0.29 Y 15.0 ft2 1 ft 5 in 1 ft 4 in None None 4 N=>S 7 Vinyl Low;E Single Yes 0.39 0.29 Y 41.0 ft2 1 ft 5 in 1 ft 4 in None None 5 E=>W 9 Vinyl Low' E Single Yes 0.39 0.29 Y 20.0 ft2 1 ft 5 in 1 ft 4 in None None 6 E=>W 11 Vinyl Low2E Single Yes 0.39 0.29 Y 15.0 ft2 1 ft 5 in 1 ft 4 in None None Ii 4 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 400 ft2 400 ft2 20 ft 8 ft 11 ' I ' i I 4/5/2022 9:42 PM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 6 1 � 3 i I ! I FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 966.7 53.03 99.57 .0902 5 i HEATING SYSTEM # System Type I Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER:14.528.6 kBtu/hr cfm 0.7 1 sys#1 � 9 I HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation j 1 Electric No I Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 ! DUCTS y �I ----Supply--; ---Return---- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6' �175 ft2 Foyer 10 ft2 Proposed Qn Foyer ---cfm 116.0 cfm 0.08 0.50 1 1 TEMPERATURES Programable Thermostat:N Ceiling Fans: Coolin [ ]Jan [ ]Feb ]Mar Apr Ma X Jun X Jul X Aug Se Oct Nov Dec Heating [X]Jan f X;Feb f X]Mar f Apr I May 4 j Jun f l Jul 4 j Aug 4 i Sep Oct NovOct �X�Nov �X Dec Venting [ ]Jan [ ]Feb Mar [X Apr May [ Jun [ Jul [ Aug [ Sep Dec I I I i i i II i i I I I i al i 4/5/2022 9:42 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 5 f 6 ° I ,' II j FORM R405-2020INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1i 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78; 78 78 78 78 78 78 78 80 80 80 80 PM 801 80 80 80 78 78 78 78 78 78 78 7�8 Cooling(WEH) AM 781 78 78 78 78 78 78 78 80 80 80 80 PM 80j 80 80 80 78 78 78 78 78 78 78 7�8 Heating(WD) AM 651 65 65 65 65 65 65 68 68 68 68 68 PM 68i 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65i 65 65 65 65 65 65 68 68 68 68 68 PM 681 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space ; Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 M Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M Bath { Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 I Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. I ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Great Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 lbs/sq.ft. ft2 ft 0.3 Kitchen Default(8lbs/sq.ft. ! ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/s .ft. ft2 ft 0.3 Hall 2 �I 1 I� I I I i I III it I II II i II I I I� I ' I I 'I 4/5/2022 9:42 PM EnerOGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 6 of 6 � I 'I 1 ! I 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA J I' Project Name: Ravina 3A Builder Name: Street: Garage Left Permit Office: City,State,Zip: Port St.Lucie',',FL, Permit Number: v Owner: Ravinia 3A-Left Hand Garage Jurisdiction: w Design Location: FL,Fort Pierce' U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous,air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier'in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction lof the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls Walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity 1 sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed s walls shall be installed in substantial contact and continuous alignment with the air barrier. { Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. I' Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts,penetrations Duct shafts,f utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. i Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that oni installation readily conforms to available space shall extend behind piping and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between firellsprmnkler cover a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 4/5/2022 9:43 PM Energy,Gauge@ USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 1of 1 { I FORM 4R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 , b i The-lower the EnergyPerformance Index, the more efficient the home. Garage Left, Port St. Lucie, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2._ Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1168.00 ft2 b.Frame-Wood,Adjacent R=13.0 160.00 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 11.Ceiling Type and insulation level Insulation Area a.Under Attic(Vented) R=30.0 1450.00 ft2 6. Conditioned floor area(ft2) 1450 b.N/A R= ft2 7. Windows*' Description Area c.N/A R= ft2 a. U-Factor. Sgl,U=0.39 126.00 ft2 12.Ducts, location&insulation level R ft2 SHGC: SHGC=0.29 a.Sup:Attic,Ret:Foyer,AH:Foyer 6 75 b.',U-Factor: N/A ft2 ,SHGC: 13.Cooling systems kBtu/hr Efficiency c. 'U-Factor: N/A ft2 a.Central Unit 28.6 SEER:14.50 SHGC: d. U-Factor: N/A ft2 i SHGC: 14.Heating systems kBtu/hr Efficiency a.Electric Strip Heat 27.0 COP:1.00 j Area Weighted Average Overhang Depth: 1.417 ft. Area Weighted Average SHGC: 0.290 8. Skylights Description Area 15.Hot water systems a. U-Factor(AVG): N/A ft2 a.Electric Cap:50 gallons SHGC(AVG): N/A EF:0.95 b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1450.00 ft2 N/A R= ft2 Credits(Performance method) CF li. c.N/A R= ft2 i certify that this home has complied,with the Florida Energy Efficiency Code for Building .; CHEST`� Construction through the above ener saving features which will be ' �4r 9 installed or exceeded) O in this home before final inspection. 'Otherwise, a new EPL Display Card will be completed -� v- based'on installed Code compliant features. ff"� ''c. -n 4"'1 Builder Signature: Date: Address of New Home: ..� � ,l City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/5/2022 9:42 PM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 i I i i I i