Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Wind load cert Giuliano
66 West Flagler Street Suite 900 - #4395 Miami, FL 33130 l 754.701.7126 admin@Jbdteam.com l www.Jbdteam.com Date: 11/29/21 Project: Giuliano Residence / 9500 S Ocean Dr, Unit #1406, Jensen Beach, FL Re: Wind Loads MecaWind v2351 Software Developer: Meca Enterprises Inc., www.meca.biz, Copyright © 2020 Calculations Prepared by: Calculations Prepared For: JBD Client: Giuliano Residence Miami, Florida, 33130 Project #: 21012 Date: Nov 29, 2021 Location: 9500 S Ocean Dr., Unit #1406, Jensen Beach, FL 34957 Designer: Julio Gonzalez, P.E. Description: Windows and Door Retrofit File Location : D:\AHP 21012 Giuliano Residence\Wind Loads\Giuliano Residence mecawind.wnd Basic Wind Parameters Wind Load Standard = ASCE 7-16 Exposure Category = D Wind Design Speed = 170.0 mph Risk Category = II Structure Type = Building Building Type = Enclosed Building Inputs RoofType: Building Roof Type = Flat : Flat Roof = RfHt : Roof Height = 200.000 ft W : Building Width = 80.000 ft L : Building Length = 177.000 ft OH : Type of Overhang = None Parapet : Type of Parapet = Parapet Par : Is there a Parapet = True PHt : Height of Parapet = 3.000 ft Por : Parapet Porosity = Solid P_GCPi : Parapet Int Press = +/-0.00 OH_ALL : None = 0.000 ft Main Wind Force Resisting System (MWFRS) Calculations per Ch 27 Part 1: h = Mean Roof Height above grade = 200.000 ft Kh = 15 ft [4.572 m]< Z <Zg -->(2.01*(Z/zg)^(2/Alpha) {Table 26.10-1}= 1.616 Kzt = Topographic Factor is 1 since no Topographic feature specified = 1.000 Kd = Wind Directionality Factor per Table 26.6-1 = 0.85 Zg = Elevation above Sea Level = 0.000 ft Ke = Ground Elevation Factor: Ke = e^-(0.0000362*Zg) {Table 26.9-1} = 1.000 GCPi = Ref Table 26.13-1 for Enclosed Building = +/-0.18 RA = Roof Area = 14160.00 sq ft LF = Load Factor based upon ASD Design = 0.60 qh = (0.00256 * Kh * Kzt * Kd * Ke * V^2) * LF = 60.99 psf qin = For Negative Internal Pressure of Enclosed Building use qh*LF = 60.99 psf qip = For Positive Internal Pressure of Enclosed Building use qh*LF = 60.99 psf Gust Factor Calculation: Gust Factor Category I Rigid Structures - Simplified Method G1 = For Rigid Structures (Nat. Freq.>1 Hz) use 0.85 = 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm = 0.6 * Ht = 120.000 ft Izm = Cc * (33 / Zm) ^ 0.167 = 0.121 Lzm = L * (Zm / 33) ^ Epsilon = 763.830 Q = (1 / (1 + 0.63 * ((B + Ht) / Lzm)^0.63))^0.5 = 0.866 G2 = 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm)) = 0.874 Gust Factor Used in Analysis G = Lessor Of G1 Or G2 = 0.850 Components and Cladding (C&C) Calculations per Ch 30 Part 3: Theta = Slope of Roof = 0.0 Deg h = Mean Roof Height above grade = 200.000 ft Kh = 15 ft [4.572 m]< Z <Zg -->(2.01*(Z/zg)^(2/Alpha) {Table 26.10-1}= 1.616 Kzt = Topographic Factor is 1 since no Topographic feature specified = 1.000 Kd = Wind Directionality Factor per Table 26.6-1 = 0.85 GCPi = Ref Table 26.13-1 for Enclosed Building = +/-0.18 LF = Load Factor based upon ASD Design = 0.60 qh = (0.00256 * Kh * Kzt * Kd * Ke * V^2) * LF = 60.99 psf LHD = Least Horizontal Dimension: Min(B, L) = 80.000 ft a1 = Min(0.1 * LHD, 0.4 * h = 8.000 ft a = Max(a1, 0.04 * LHD, 3 ft [0.9 m]) = 8.000 ft Effective Wind Area for C&C per Ch 30 Part 3 Description Zone Elev Width Span 1/3 Area Ref GCp GCp Length Rule Fig Max Min ft ft ft ft sq ft ----------------------------------------------------------- Worst case 5 5 110.00 5.000 2.000 No 10.00 30.6-1 0.900 -1.800 Worst case 4 4 110.00 5.000 2.000 No 10.00 30.6-1 0.900 -0.900 Wind Pressures for C&C per Ch 30 Part 3 All wind pressures include a load factor of 0.6 Description Zone qi q_ww q_oth P_WW P_WW P_Oth P_Oth P_Max P_Min Max Min Max Min ft psf psf psf psf psf psf psf psf psf ------------------------------------------------------------------- Worst case 5 5 60.99 54.97 60.99 60.45 -109.93 65.87 -120.77 65.87 -120.77 Worst case 4 4 60.99 54.97 60.99 60.45 -60.45 65.87 -65.87 65.87 -65.87 GCp = Walls and Flat Roofs (Slope < 10 Deg) use Fig 30.56-1 = Per Fig 30.5-1 Note 6 Roof Slopes >= 10 Deg use Fig 30.3-2A, B and C qi = qh for Enclosed buildings q_ww = qz for Windward walls q_oth = qh for Leeward walls, Side walls and Roofs P_WW = Press on Windward Walls: q_ww * GCp - qi * (+/-GCpi) [Eqn 30.5-1] P_Oth = Press on Leeward/Side/Roof: q_oth * GCp - qi * (+/-GCpi) [Eqn 30.5-1] P_Max = Max Positive Pressure on C&C component: Max(P_WW, P_Oth) P_Min = Max negative pressure on C&C component: Min(P_WW, P_Oth) * Per Para 30.2.2 the Minimum Pressure for C&C is 9.60 psf [0.460 kPa] {Includes LF}