Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED HALGAS- MANUAL J
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22 Right-Suite® Universal 2021 21.0.02 RSU08101 Page 1 E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Project Summary Feb 10, 2022Date:AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information HALGAS RESIDENCEFor: LOT #24- DIAMOND SANDS, JENSEN BEACH, FL Notes: Design Information West Palm Beach Intl AP, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F45 Outside db °F91Inside db °F70 Inside db °F75 Design TD °F25 Design TD °F16Daily range L Relative humidity %50Moisture difference gr/lb58 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh31017 Structure Btuh35400 Ducts Btuh0 Ducts Btuh0 Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 (none)(none) Humidification Btuh0 Blower Btuh0 Piping Btuh0 Equipment load Btuh31017 Use manufacturer's data n Rate/swing multiplier 0.96 Infiltration Equipment sensible load Btuh33984 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average 0Fireplaces Structure Btuh6621 Ducts Btuh0 Central vent (0 cfm)Btuh0 CoolingHeating (none) 26852685Area (ft²)Equipment latent load Btuh6621 2685026850Volume (ft³) Air changes/hour 0.150.28 Equipment Total Load (Sen+Lat)Btuh40605 Equiv. AVF (cfm)67124 Req. total capacity at 0.70 SHR ton4.0 Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond 24ABC648A00310 AHRI ref Coil FV4CNB006L AHRI ref 9171220 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW13.1 Sensible cooling Btuh32200 Heating output Btuh44711 Latent cooling Btuh13800 Temperature rise °F27 Total cooling Btuh46000 Actual air flow cfm1533 Actual air flow cfm1533 Air flow factor cfm/Btuh0.049 Air flow factor cfm/Btuh0.043 Static pressure in H2O1.00 Static pressure in H2O1.00 Space thermostat Load sensible heat ratio 0.84 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22 Right-Suite® Universal 2021 21.0.02 RSU08101 Page 2 E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Project Summary Feb 10, 2022Date:AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information HALGAS RESIDENCEFor: LOT #24- DIAMOND SANDS, JENSEN BEACH, FL Notes: Design Information West Palm Beach Intl AP, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F45 Outside db °F91Inside db °F70 Inside db °F75 Design TD °F25 Design TD °F16Daily range L Relative humidity %50Moisture difference gr/lb58 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh29657 Structure Btuh34874 Ducts Btuh7772 Ducts Btuh0 Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 (none)(none) Humidification Btuh0 Blower Btuh0 Piping Btuh0 Equipment load Btuh37429 Use manufacturer's data n Rate/swing multiplier 0.96 Infiltration Equipment sensible load Btuh33479 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average 0Fireplaces Structure Btuh4490 Ducts Btuh3134 Central vent (0 cfm)Btuh0 CoolingHeating (none) 25842584Area (ft²)Equipment latent load Btuh7623 2719027190Volume (ft³) Air changes/hour 0.150.28 Equipment Total Load (Sen+Lat)Btuh41102 Equiv. AVF (cfm)68128 Req. total capacity at 0.70 SHR ton4.0 Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond 24ABC648A00310 AHRI ref Coil FV4CNB006L AHRI ref 9171220 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW12.3 Sensible cooling Btuh32200 Heating output Btuh42064 Latent cooling Btuh13800 Temperature rise °F25 Total cooling Btuh46000 Actual air flow cfm1533 Actual air flow cfm1533 Air flow factor cfm/Btuh0.041 Air flow factor cfm/Btuh0.044 Static pressure in H2O1.00 Static pressure in H2O1.00 Space thermostat Load sensible heat ratio 0.82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 1E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name AHU 1 ELEV 1ST FLR 2 Exposed wall 267.0 ft 5.0 ft 3 Room height 10.0 ft 10.0 heat/coolft 4 Room dimensions ft5.0x6.0 5 Room area 2685.0 ft²30.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 610 486 1737 1373 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 13 0 203 196 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 20 0 317 305 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 20 0 325 313 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 13.9113.91 72 0 1170 1002 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 640 16 57 45 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.8633.86 144 4 2340 4876 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 28.4328.43 240 7 3900 6822 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 16.3616.36 240 74 3900 3926 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 580 481 1720 1358 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 10.0210.02 99 99 1609 992 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 840 487 1741 1375 50 50 179 141 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 36 1 585 1212 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 27 1 439 909 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 40 1 650 1350 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 30 1 488 1012 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 18.8618.86 88 3 1430 1660 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 14.7214.72 132 64 2145 1943 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 131 131 185 208 0 0 0 0 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 754 78 2656 0 30 5 170 0 6 c) AED excursion 0 -10 Envelope loss/gain 27597 30878 349 131 12 a) Infiltration 3420 1173 64 22 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 3350 0 Subtotal (lines 6 to 13)31017 35400 413 153 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 -413 -153 14 Subtotal 31017 35400 0 0 15 Duct loads 0%0%0 0 0%0%0 0 Total room load 31017 35400 0 0 Air required (cfm)Air required (cfm)1533 1533 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 2E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name FOYER ELEV 2ND FLR 2 Exposed wall 15.0 ft 5.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft322.0x1.0 ft5.0x6.0 5 Room area 322.0 ft²30.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 13.9113.91 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.8633.86 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 28.4328.43 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 16.3616.36 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 150 80 286 226 50 50 179 141 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 40 1 650 1350 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 30 1 488 1012 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 18.8618.86 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 14.7214.72 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 7 7 10 11 5 5 7 8 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 322 15 509 0 0 0 0 0 6 c) AED excursion 692 -10 Envelope loss/gain 1943 3291 186 139 12 a) Infiltration 192 66 64 22 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 400 0 Subtotal (lines 6 to 13)2135 3757 250 161 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 1326 496 -250 -161 14 Subtotal 3461 4253 0 0 15 Duct loads 0%0%0 0 0%0%0 0 Total room load 3461 4253 0 0 Air required (cfm)Air required (cfm)171 184 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 3E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name AHU 1 CLST WINE CLST 2 Exposed wall 0 ft 0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft5.0x3.0 ft5.0x3.0 5 Room area 15.0 ft²15.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 13.9113.91 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.8633.86 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 28.4328.43 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 16.3616.36 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 18.8618.86 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 14.7214.72 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 0 0 0 0 0 0 0 0 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 0 Envelope loss/gain 0 0 0 0 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)0 0 0 0 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 0%0%0 0 0%0%0 0 Total room load 0 0 0 0 Air required (cfm)Air required (cfm)0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 4E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name POWDER RM CHASE AHU 1 2 Exposed wall 17.0 ft 11.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft6.0x11.0 ft5.0x6.0 5 Room area 66.0 ft²30.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 13.9113.91 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.8633.86 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 28.4328.43 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 16.3616.36 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 110 110 393 311 60 60 215 169 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 60 60 215 169 50 50 179 141 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 18.8618.86 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 14.7214.72 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 6 6 8 10 4 4 6 6 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 0 0 0 0 30 11 373 0 6 c) AED excursion -71 -22 Envelope loss/gain 616 419 772 295 12 a) Infiltration 218 75 141 48 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 600 0 Subtotal (lines 6 to 13)834 1093 913 343 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 -913 -343 14 Subtotal 834 1093 0 0 15 Duct loads 0%0%0 0 0%0%0 0 Total room load 834 1093 0 0 Air required (cfm)Air required (cfm)41 47 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 5E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name VESTIBULE GUEST BEDROOM 2 Exposed wall 0 ft 33.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft56.0x1.0 ft232.0x1.0 5 Room area 56.0 ft²232.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 0 0 0 0 130 130 465 367 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 13.9113.91 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.8633.86 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 28.4328.43 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 16.3616.36 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 0 0 0 0 40 40 143 113 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 0 0 0 0 160 72 257 203 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 18.8618.86 0 0 0 0 88 3 1430 1660 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 14.7214.72 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 0 0 0 0 34 34 48 54 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 616 Envelope loss/gain 0 0 2343 3014 12 a) Infiltration 0 0 423 145 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)0 0 2766 3159 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 0 0 2766 3159 15 Duct loads 0%0%0 0 0%0%0 0 Total room load 0 0 2766 3159 Air required (cfm)Air required (cfm)0 0 137 137 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 6E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name GUEST WIC GUEST BATH 2 Exposed wall 0 ft 6.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft6.0x5.0 ft12.0x6.0 5 Room area 30.0 ft²72.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 0 0 0 0 60 48 170 134 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 13 0 203 196 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 13.9113.91 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.8633.86 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 28.4328.43 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 16.3616.36 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 18.8618.86 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 14.7214.72 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 0 0 0 0 0 0 0 0 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -43 -70 Envelope loss/gain 0 -43 373 259 12 a) Infiltration 0 0 77 26 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 700 800 Subtotal (lines 6 to 13)0 657 450 1086 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 0 657 450 1086 15 Duct loads 0%0%0 0 0%0%0 0 Total room load 0 657 450 1086 Air required (cfm)Air required (cfm)0 28 22 47 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 7E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name PANTRY KITCHEN 2 Exposed wall 7.0 ft 42.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft72.0x1.0 ft460.0x1.0 5 Room area 72.0 ft²460.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 70 51 181 143 200 200 715 565 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 20 0 317 305 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 13.9113.91 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 0 0 0 0 220 -20 -72 -56 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.8633.86 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 28.4328.43 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 16.3616.36 0 0 0 0 240 74 3900 3926 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 18.8618.86 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 14.7214.72 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 0 0 0 0 0 0 0 0 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -69 227 Envelope loss/gain 497 379 4544 4662 12 a) Infiltration 90 31 538 184 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 650 0 Subtotal (lines 6 to 13)587 1060 5082 4846 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 587 1060 5082 4846 15 Duct loads 0%0%0 0 0%0%0 0 Total room load 587 1060 5082 4846 Air required (cfm)Air required (cfm)29 46 251 210 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 8E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LIVING RM CHASE 2 Exposed wall 43.0 ft 8.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft729.0x1.0 ft4.0x4.0 5 Room area 729.0 ft²16.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 90 18 64 51 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 13.9113.91 72 0 1170 1002 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 240 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.8633.86 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 28.4328.43 240 7 3900 6822 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 16.3616.36 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 0 0 0 0 40 40 143 113 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 100 37 132 104 40 40 143 113 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 36 1 585 1212 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 27 1 439 909 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 18.8618.86 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 14.7214.72 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 62 62 88 98 13 13 18 21 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 192 11 384 0 0 0 0 0 6 c) AED excursion -633 -17 Envelope loss/gain 6763 9566 304 229 12 a) Infiltration 551 189 102 35 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)7313 9754 407 265 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 657 425 -407 -265 14 Subtotal 7970 10180 0 0 15 Duct loads 0%0%0 0 0%0%0 0 Total room load 7970 10180 0 0 Air required (cfm)Air required (cfm)394 441 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 9E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name OFFICE/CLUB RM CABANA 2 Exposed wall 54.0 ft 21.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft456.0x1.0 ft6.0x9.0 5 Room area 456.0 ft²54.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 0 0 0 0 60 40 143 113 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 20 0 325 313 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 13.9113.91 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 120 -24 -86 -68 60 60 215 169 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.8633.86 144 4 2340 4876 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 28.4328.43 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 16.3616.36 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 240 141 504 398 90 90 322 254 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 10.0210.02 99 99 1609 992 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 180 48 172 136 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.6733.67 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 18.8618.86 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 14.7214.72 132 64 2145 1943 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 0 0 0 0 0 0 0 0 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 126 15 507 0 54 21 713 0 6 c) AED excursion -519 -70 Envelope loss/gain 7190 7758 1717 780 12 a) Infiltration 692 237 269 92 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 200 Subtotal (lines 6 to 13)7882 7995 1986 1072 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 7882 7995 1986 1072 15 Duct loads 0%0%0 0 0%0%0 0 Total room load 7882 7995 1986 1072 Air required (cfm)Air required (cfm)390 346 98 46 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 10E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name AHU 2 TV ROOM 2 Exposed wall 260.0 ft 29.0 ft 3 Room height 10.5 ft 10.0 heat/coolft 4 Room dimensions ft264.0x1.0 5 Room area 2584.0 ft²264.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 660 600 2145 1695 150 150 536 424 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 60 0 975 938 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 640 202 722 570 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 15.6415.64 18 18 293 282 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.5833.58 40 2 650 1343 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.7533.75 150 5 2438 5062 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 18 2 293 325 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 15 2 244 271 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 42 2 683 785 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 35 2 569 654 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 10.0210.02 120 120 1950 1202 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 750 680 2431 1921 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 24 24 390 375 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 13 13 210 202 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 33 33 536 516 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 690 357 1276 1008 140 60 215 169 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 40 1 650 1350 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 60 2 975 2025 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 40 1 650 1350 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.8133.81 33 1 536 1116 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.0321.03 80 29 1300 1683 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.1921.19 80 3 1300 1695 80 3 1300 1695 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 2584 2584 3658 4102 264 264 374 419 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 274 38 1274 0 0 0 0 0 6 c) AED excursion 0 425 Envelope loss/gain 26147 30470 2424 3132 12 a) Infiltration 3510 1203 371 127 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 3200 0 Subtotal (lines 6 to 13)29657 34874 2796 3260 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 154 95 14 Subtotal 29657 34874 2950 3355 15 Duct loads 26%0%7772 0 26%0%773 0 Total room load 37429 34874 3724 3355 Air required (cfm)Air required (cfm)1533 1533 153 147 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 11E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name TV STORAGE RM UTILITY RM 2 Exposed wall 5.0 ft 17.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft2.0x3.0 ft168.0x1.0 5 Room area 6.0 ft²168.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.5833.58 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 30 30 107 85 110 97 347 274 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 13 13 210 202 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 20 20 72 56 60 60 215 169 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.8133.81 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.0321.03 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.1921.19 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 6 6 8 10 168 168 238 267 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -20 -112 Envelope loss/gain 187 131 1009 800 12 a) Infiltration 64 22 218 75 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)251 153 1227 875 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -251 -153 294 190 14 Subtotal 0 0 1522 1064 15 Duct loads 26%0%0 0 26%0%399 0 Total room load 0 0 1920 1064 Air required (cfm)Air required (cfm)0 0 79 47 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 12E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name AHU 2 CLST M WIC 1 2 Exposed wall 0 ft 17.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft4.0x3.0 ft10.0x17.0 5 Room area 12.0 ft²170.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 0 0 0 0 170 170 608 480 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.5833.58 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.8133.81 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.0321.03 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.1921.19 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 12 12 17 19 170 170 241 270 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -2 -128 Envelope loss/gain 17 17 848 622 12 a) Infiltration 0 0 218 75 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 300 Subtotal (lines 6 to 13)17 17 1066 997 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -17 -17 0 0 14 Subtotal 0 0 1066 997 15 Duct loads 26%0%0 0 26%0%279 0 Total room load 0 0 1346 997 Air required (cfm)Air required (cfm)0 0 55 44 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 13E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name MASTER BEDROOM M WIC 2 2 Exposed wall 41.0 ft 0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft382.0x1.0 ft13.0x6.0 5 Room area 382.0 ft²78.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 200 140 501 395 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 60 0 975 938 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 160 10 36 28 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.5833.58 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.7533.75 150 5 2438 5062 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 50 50 179 141 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.8133.81 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.0321.03 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.1921.19 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 382 382 541 606 78 78 110 124 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 128 14 466 0 0 0 0 0 6 c) AED excursion -837 -14 Envelope loss/gain 5135 6335 110 110 12 a) Infiltration 525 180 0 0 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)5660 6515 110 110 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 5 5 14 Subtotal 5660 6515 115 115 15 Duct loads 26%0%1483 0 26%0%30 0 Total room load 7143 6515 145 115 Air required (cfm)Air required (cfm)293 286 6 5 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 14E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name M BATH M TOILET 2 Exposed wall 19.0 ft 0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft194.0x1.0 ft4.0x6.0 5 Room area 194.0 ft²24.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 40 40 143 113 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 150 92 329 260 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 15.6415.64 18 18 293 282 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.5833.58 40 2 650 1343 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.8133.81 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.0321.03 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.1921.19 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 194 194 275 308 24 24 34 38 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 18 2 60 0 0 0 0 0 6 c) AED excursion -272 -4 Envelope loss/gain 1749 2034 34 34 12 a) Infiltration 243 83 0 0 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1992 2117 34 34 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1992 2117 34 34 15 Duct loads 26%0%522 0 26%0%9 0 Total room load 2514 2117 43 34 Air required (cfm)Air required (cfm)103 93 2 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 15E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LOUNGE STAIRS 3RD FLR 2 Exposed wall 23.0 ft 17.0 ft 3 Room height 10.0 heat/coolft 18.8 heat/coolft 4 Room dimensions ft468.0x1.0 ft11.0x14.0 5 Room area 468.0 ft²154.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 150 30 107 85 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.5833.58 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 10.0210.02 120 120 1950 1202 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 0 0 0 0 180 147 526 415 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 33 33 536 516 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 80 0 0 0 130 37 132 104 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 40 1 650 1350 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 60 2 975 2025 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 40 1 650 1350 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.8133.81 0 0 0 0 33 1 536 1116 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.0321.03 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.1921.19 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 468 468 663 743 154 154 218 244 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 0 0 0 0 8 1 28 0 6 c) AED excursion 124 282 Envelope loss/gain 4020 4854 2951 4703 12 a) Infiltration 295 101 397 136 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 1500 Subtotal (lines 6 to 13)4314 4955 3349 6339 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 245 153 152 93 14 Subtotal 4559 5108 3501 6432 15 Duct loads 26%0%1195 0 26%0%917 0 Total room load 5754 5108 4418 6432 Air required (cfm)Air required (cfm)236 225 181 283 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 16E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name ELEV 3RD FLR WIC 3 2 Exposed wall 5.0 ft 5.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft5.0x5.0 ft5.0x9.0 5 Room area 25.0 ft²45.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.5833.58 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 50 50 179 141 50 50 179 141 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.8133.81 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.0321.03 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.1921.19 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 25 25 35 40 45 45 64 71 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -23 -27 Envelope loss/gain 214 158 242 186 12 a) Infiltration 64 22 64 22 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)278 180 307 208 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -278 -180 0 0 14 Subtotal 0 0 307 208 15 Duct loads 26%0%0 0 26%0%80 0 Total room load 0 0 387 208 Air required (cfm)Air required (cfm)0 0 16 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 17E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 3 WIC 2 2 Exposed wall 26.0 ft 0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft189.0x1.0 ft5.0x9.0 5 Room area 189.0 ft²45.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.5833.58 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 130 130 465 367 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 130 50 179 141 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.8133.81 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.0321.03 80 29 1300 1683 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.1921.19 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 189 189 268 300 45 45 64 71 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 12 2 56 0 0 0 0 0 6 c) AED excursion 717 -8 Envelope loss/gain 2267 3208 64 63 12 a) Infiltration 333 114 0 0 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2600 3322 64 63 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2600 3322 64 63 15 Duct loads 26%0%681 0 26%0%17 0 Total room load 3282 3322 80 63 Air required (cfm)Air required (cfm)134 146 3 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 18E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH 3 BATH 2 2 Exposed wall 5.0 ft 5.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft13.0x5.0 ft13.0x5.0 5 Room area 65.0 ft²65.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.5833.58 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 50 38 136 107 50 38 136 107 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 12 12 195 188 12 12 195 188 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.8133.81 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.0321.03 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.1921.19 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 65 65 92 103 65 65 92 103 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -127 -127 Envelope loss/gain 423 271 423 271 12 a) Infiltration 64 22 64 22 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 700 700 Subtotal (lines 6 to 13)487 993 487 993 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 487 993 487 993 15 Duct loads 26%0%128 0 26%0%128 0 Total room load 615 993 615 993 Air required (cfm)Air required (cfm)25 44 25 44 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-10 15:48:22Right-Suite® Universal 2021 21.0.02 RSU08101 Page 19E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Feb 10, 2022Date:AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 STORAGE 2 Exposed wall 40.0 ft 6.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft221.0x1.0 ft3.0x3.0 5 Room area 221.0 ft²9.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.583.58 2.822.82 100 100 358 282 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.583.58 2.822.82 180 70 250 198 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.5833.58 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 18 2 293 325 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.0718.07 15 2 244 271 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 42 2 683 785 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 18.6918.69 35 2 569 654 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 16.2516.25 10.0210.02 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.583.58 2.822.82 120 120 429 339 30 30 107 85 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 16.2516.25 15.6415.64 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.583.58 2.822.82 0 0 0 0 30 30 107 85 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.7533.75 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 33.8133.81 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.0321.03 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 16.2516.25 21.1921.19 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.421.42 1.591.59 221 221 313 351 9 9 13 14 FF 22A-tph22A-tph 1.3581.358 --33.9533.95 0.000.00 108 20 664 0 0 0 0 0 6 c) AED excursion 177 -24 Envelope loss/gain 3801 3383 227 160 12 a) Infiltration 512 176 77 26 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)4313 3558 304 186 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 -304 -186 14 Subtotal 4313 3558 0 0 15 Duct loads 26%0%1130 0 26%0%0 0 Total room load 5443 3558 0 0 Air required (cfm)Air required (cfm)223 156 0 0 2022-Feb-10 15:48:39 Right-Suite® Universal 2021 21.0.02 RSU08101 Page 1 E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Duct System Summary Feb 10, 2022Date:AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information HALGAS RESIDENCEFor: LOT #24- DIAMOND SANDS, JENSEN BEACH, FL CoolingHeating External static pressure in H2O1.00in H2O1.00 Pressure losses in H2O0in H2O0 Available static pressure in H2O1.00in H2O1.00 Supply / return available pressure 0.500 / 0.500 in H2O in H2O0.500 / 0.500 Lowest friction rate in/100ft1.000in/100ft1.000 Actual air flow cfm1533cfm1533 Total effective length (TEL)ft192 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st8135.056.7VlFx0x06.01.00046981986hCABANA st9129.030.0VlFx0x07.01.00092862127cFOYER st9129.029.0VlFx0x07.01.00092862127cFOYER-A st1115.013.2VlFx0x06.01.00047221086cGUEST BATH st1115.018.0VlFx0x07.01.0001371373159cGUEST BEDROOM st1115.014.3VlFx0x05.01.000280657cGUEST WIC st7135.029.4VlFx0x07.01.0001051262541hKITCHEN st7135.025.4VlFx0x07.01.0001051262541hKITCHEN-A 95.010.2VlFx0x07.01.000110982545cLIVING RM st2115.033.6VlFx0x07.01.000110982545cLIVING RM-A st2115.035.5VlFx0x07.01.000110982545cLIVING RM-B st2115.036.6VlFx0x07.01.000110982545cLIVING RM-C st8135.057.3VlFx0x07.01.0001151302627hOFFICE/CLUB RM st8135.049.7VlFx0x07.01.0001151302627hOFFICE/CLUB RM-A st8135.051.1VlFx0x07.01.0001151302627hOFFICE/CLUB RM-B st7135.030.9VlFx0x06.01.00046291060cPANTRY st1115.016.9VlFx0x06.01.00047411093cPOWDER RM 2022-Feb-10 15:48:39 Right-Suite® Universal 2021 21.0.02 RSU08101 Page 2 E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st9 Peak AVF 171 184 1.000 528 8.0 0x0 VinlFlx st3 st3 Peak AVF 171 184 1.000 528 8.0 0x0 VinlFlx st7 Peak AVF 280 256 1.000 634 9.0 0x0 VinlFlx st1 st1 Peak AVF 480 515 1.000 656 12.0 0x0 VinlFlx st8 Peak AVF 488 393 1.000 894 10.0 0x0 VinlFlx st2 st2 Peak AVF 783 723 1.000 733 14.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb3 0x 15330 1533 0 0 0 0 x0 0 VlFx 2022-Feb-10 15:48:39 Right-Suite® Universal 2021 21.0.02 RSU08101 Page 3 E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Duct System Summary Feb 10, 2022Date:AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information HALGAS RESIDENCEFor: LOT #24- DIAMOND SANDS, JENSEN BEACH, FL CoolingHeating External static pressure in H2O1.00in H2O1.00 Pressure losses in H2O0in H2O0 Available static pressure in H2O1.00in H2O1.00 Supply / return available pressure 0.500 / 0.500 in H2O in H2O0.500 / 0.500 Lowest friction rate in/100ft1.000in/100ft1.000 Actual air flow cfm1533cfm1533 Total effective length (TEL)ft185 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st10135.046.3VlFx0x06.01.0004425993cBATH 2 st10135.049.7VlFx0x06.01.0004425993cBATH 3 st10135.050.1VlFx0x08.01.0001562235443hBEDROOM 2 st6115.038.2VlFx0x08.01.0001461343322cBEDROOM 3 st6115.040.1VlFx0x08.01.0002252365754hLOUNGE st5115.024.3VlFx0x06.01.00047511257hM BATH st5115.028.7VlFx0x06.01.00047511257hM BATH-A st5115.024.6VlFx0x04.01.0001243hM TOILET st4115.010.2VlFx0x06.01.00044551346hM WIC 1 95.04.0VlFx0x04.01.00056145hM WIC 2 st5115.024.1VlFx0x08.01.0001431463572hMASTER BEDROOM st5115.027.7VlFx0x08.01.0001431463572hMASTER BEDROOM-A st6115.044.0VlFx0x08.01.000141903216cSTAIRS 3RD FLR st6115.034.5VlFx0x08.01.000141903216cSTAIRS 3RD FLR-A st4115.012.2VlFx0x08.01.0001471533724hTV ROOM 95.04.2VlFx0x06.01.00047791920hUTILITY RM st10135.046.5VlFx0x04.01.0003380hWIC 2 st6115.036.7VlFx0x04.01.000916387hWIC 3 2022-Feb-10 15:48:39 Right-Suite® Universal 2021 21.0.02 RSU08101 Page 4 E:\Documnets\Wrightsoft HVAC\HALGAS RESIDENCE.rup Calc = MJ8 Front Door faces: S Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st10 Peak AVF 277 246 1.000 626 9.0 0x0 VinlFlx st6 st6 Peak AVF 843 909 1.000 651 16.0 0x0 VinlFlx st5 Peak AVF 397 381 1.000 728 10.0 0x0 VinlFlx st4 Peak AVF 208 191 1.000 595 8.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb2 0x 15330 1533 0 0 0 0 x0 0 VlFx ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������