Loading...
HomeMy WebLinkAboutRevision 4-19-22i OFFICE USE ONLY: DATE FILED: April 19 2022 REVISION FEE: PERMIT # 2104-0433 RECEIPT # PLANNING & DEVELOPMENTS I BUILDING &CODE REGULATION I VISION 2300 VIRGINIA AVEN t FORT PIERCE, FL34982-5652 (772)462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION F LOCATION/SITE ADDRESS: 18700 Tranquilty Base Lane Ft. Pierce 34987 DETAILED DESCRIPTION OF PROJECT REVISIONS: Permit Number 2104-0433 Revision form for WINDOW FLASHING CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: FILM Construction Consuti QUALIFIERS NAME: Patsi L. Meltzer ADDRESS: 542 NW Mercantile Place CITY: Port St Lucie STATE: Florida PHONE (DAYTIME): 562-729-7574 OWNER/BUILDER INFORMATION: NAME: CITY: PHONE (DAYTIME: LLC STATE: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9123109 Revised 06130117 STATE: ST. LUCIE CO CERT. #: 32681 FAX: ZIP: 34986 ZIP: ZIP: ind Zone - Roof Plan Rear Elevation scale: 1/4" = V-0" Wind Zones - Walls 3/8- continuous bead of caulk (back bedding) behind — buck to prevent liquid passage set flange in continuous bead of caulk across the entire face of buck -, CBS Lo�bbl� d di � d va d d a � t #/4e" .struct. shim stucco finish perimeter caulk Attach p.t. bucks J with 8d coil nails at 12"o.c. Typ. Alum. window _ jamb or sliding glass doorjamb NOTE: Method of attachment and waterproofing procedures are the same at poured concrete sill. Min. 1 1/4"" embedment at windows and min. 1 1/2" embedment at sl. gl. doors 1 /2 drywall caulk attach as per manufacturers product approvals Gunable sealants shall comply with ASTM C 920 Class 25 grade or greater for proper joint expansion Coat Bucks, Jambs, Head, & Sill of the Masonry Opening with Protecto LWM200 Waterproofing after they have been installed and Chaulked Window & Door Flashing Detail at CBS Wall Includes Buck Attachment Method corner bars at beam (outside only) (2) comer bars at footing (min.) — vert. dowel lapped with wall reinforcing, all laps 30" (min.) in grout filled cell 0 S N all comer bars to be the same size, number, and spacing as horizontial bars in footing, beams, and walls Corner Reinforcing Detail .� 2 x 4 bottom cord bracine 10'-0- Bottom Cord Lateral Brac 16"" C.M.U. WITH CELLS FILLED GROUT & (1) #5 VERT. EL P.T. 2 x 6 AT (3) SIDES OF OPENING, FASTEN TO BLOCK AS NOTED. DOOR SIDES 1/2"" x 6"REDHEADS WITH MIN. 2` x 1/8-WASHER 12' FROM ENDS AND 16`o.c. MAX, DOOR HEAD 1/4"" x 2 3/4" TAPCONS STAGGERED 24"o.c. Garage Door Buck Detail Alum. window frame 3/8- continuous bead of caulk (back bedding) behind shim to prevent liquid passage 1/4"" struct. shi set flange in continuous bead of caulk across the entire face of buck perimeter caulk corrosive resistant Tapcon concrete srews installed as specified in window manufacturers product approval window sill stucco finish c a T � Protecto LWM200 precast Coating on Outside face cons. sill and Janbs of Openings all Sides min. 8Gunable sealants shall comply with ASTM C 920 Class 25 grade or greater for proper joint expansion and contraction Typical Precast Conc. Sill Detail Coat Bucks with Protecto LWM200 Waterproofing after they have been installed and Chaulked Galv. Cap 2" dia. Galv Pipe Set bollard 12" 11� from appliance iy Galv. Collar (4) 1/4" x 2 1/4J Typical Conc. Tapcons Foundation a°Fd Detail 90 DEGREE HOOKS OVERLAP 25" MIN. HORIZ. TIE BEAM STEEL SEE WALL SECTION FOR STEEL REOUIRMENTS POURED CELLS WITH (1) #5 BAR CONTINUOUS FROM BEAM TO FOOTING 04 Change in Bond Beam Elev. t00 o U Q F L I _ v W Z � M �r J LL Lfl WU _ fn W N i c1• i.a j ., o � r T � f� r r �✓ ate revision 3/14/21 Updated to FBCR2020 4/11/22 Window &Door Flashing Detail drawn s1 checked s.l. date silai2o scale as noted job number 20013 sheet