HomeMy WebLinkAboutRevision 4-19-22i
OFFICE USE ONLY:
DATE FILED: April 19 2022
REVISION FEE:
PERMIT # 2104-0433
RECEIPT #
PLANNING & DEVELOPMENTS I
BUILDING &CODE REGULATION I VISION
2300 VIRGINIA AVEN t
FORT PIERCE, FL34982-5652
(772)462.1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION F
LOCATION/SITE
ADDRESS:
18700 Tranquilty Base Lane Ft. Pierce 34987
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Permit Number 2104-0433 Revision form for WINDOW FLASHING
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #:
BUSINESS NAME: FILM Construction Consuti
QUALIFIERS NAME: Patsi L. Meltzer
ADDRESS: 542 NW Mercantile Place
CITY: Port St Lucie STATE: Florida
PHONE (DAYTIME): 562-729-7574
OWNER/BUILDER INFORMATION:
NAME:
CITY:
PHONE (DAYTIME:
LLC
STATE:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
SLCCC: 9123109
Revised 06130117
STATE:
ST. LUCIE CO CERT. #: 32681
FAX:
ZIP: 34986
ZIP:
ZIP:
ind Zone - Roof Plan
Rear Elevation
scale: 1/4" = V-0"
Wind Zones - Walls
3/8- continuous bead of
caulk (back bedding) behind —
buck to prevent liquid passage
set flange in continuous
bead of caulk across the
entire face of buck -,
CBS
Lo�bbl�
d di � d va d d
a
� t
#/4e" .struct. shim
stucco finish
perimeter caulk
Attach p.t. bucks J
with 8d coil nails at
12"o.c.
Typ. Alum. window _
jamb or sliding glass
doorjamb
NOTE: Method of attachment and
waterproofing procedures are the
same at poured concrete sill.
Min. 1 1/4"" embedment
at windows and min.
1 1/2" embedment at
sl. gl. doors
1 /2 drywall
caulk
attach as per
manufacturers
product approvals
Gunable sealants shall comply with
ASTM C 920 Class 25 grade or
greater for proper joint expansion
Coat Bucks, Jambs, Head, & Sill of the Masonry Opening with Protecto LWM200
Waterproofing after they have been installed and Chaulked
Window & Door Flashing Detail at CBS Wall
Includes Buck Attachment Method
corner bars at beam
(outside only) (2) comer
bars at footing (min.) —
vert. dowel lapped with
wall reinforcing, all
laps 30" (min.) in grout
filled cell
0
S
N
all comer bars to be the
same size, number, and
spacing as horizontial bars
in footing, beams, and walls
Corner Reinforcing Detail
.�
2 x 4 bottom cord bracine
10'-0-
Bottom Cord Lateral Brac
16"" C.M.U. WITH CELLS FILLED
GROUT & (1) #5 VERT.
EL
P.T. 2 x 6 AT (3) SIDES OF
OPENING, FASTEN TO BLOCK
AS NOTED.
DOOR SIDES
1/2"" x 6"REDHEADS WITH MIN.
2` x 1/8-WASHER 12' FROM ENDS
AND 16`o.c. MAX,
DOOR HEAD
1/4"" x 2 3/4" TAPCONS STAGGERED
24"o.c.
Garage Door Buck Detail
Alum. window
frame
3/8- continuous bead of
caulk (back bedding) behind
shim to prevent liquid passage
1/4"" struct. shi
set flange in continuous
bead of caulk across the
entire face of buck
perimeter caulk
corrosive resistant
Tapcon concrete
srews installed as
specified in window
manufacturers product
approval
window sill
stucco finish
c
a T �
Protecto LWM200 precast
Coating on Outside face cons. sill
and Janbs of Openings
all Sides min. 8Gunable sealants shall comply with
ASTM C 920 Class 25 grade or
greater for proper joint expansion
and contraction
Typical Precast Conc. Sill Detail
Coat Bucks with Protecto LWM200 Waterproofing
after they have been installed and Chaulked
Galv. Cap
2" dia. Galv
Pipe
Set bollard 12" 11�
from appliance iy
Galv. Collar
(4) 1/4" x 2 1/4J Typical Conc.
Tapcons Foundation
a°Fd Detail
90 DEGREE HOOKS
OVERLAP 25" MIN.
HORIZ. TIE BEAM STEEL
SEE WALL SECTION FOR
STEEL REOUIRMENTS
POURED CELLS WITH
(1) #5 BAR CONTINUOUS
FROM BEAM TO FOOTING
04
Change in Bond Beam Elev.
t00
o
U
Q
F
L
I _
v
W
Z
�
M
�r
J
LL
Lfl
WU
_
fn
W
N
i
c1•
i.a
j
.,
o �
r
T
�
f�
r
r
�✓
ate
revision
3/14/21
Updated to
FBCR2020
4/11/22
Window &Door
Flashing Detail
drawn
s1
checked
s.l.
date
silai2o
scale
as noted
job number
20013
sheet