HomeMy WebLinkAboutEPL Display CardFORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
RECENED
ESTIMATED ENERGY PERFORMANCE INDEX* = 94 APR 0 5 2022
The lower the EnergyPerformance Index, the more efficient the home. St. Lucie County
Permitting
1, New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Sgl, U=0.65
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65
SHGC: SHGC=0.30
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. Raised Floor
c. N/A
I certify that this home has com
Construction through the abo e
in this home before final in ec
based on installed Code Dli
Builder Signature:
Address of New Home:
15 CROWN COURT, F,'ORT PIERCE, FL,
New (From Plans)
Detached
1
4
No
3854
Area
767.92 ft2
280.00 ft2
ft2
ft2
3.099 ft.
0.263
Area
ft2
Insulation
Area
R=0.0
2756.00 ft2
R=30.0
1098.00 ft2
R=
ft2
10. Wall Type and Insulation
a. Concrete Block - Int Insul, Exterior
b. Interior Frame - Wood, Interior
c. N/A
d. N/A
11. Ceiling Type and insulation level
a. Roof Deck (Unvented)
b. N/A
c. N/A
j 12. Ducts, location & insulation level
a. Sup: Attic, Ret: Attic, AH: Attic
b. Sup: Attic, Ret: Attic, AH: MECH RM
13. Cooling systems
a. Central Unit
b. Central Unit
c. Central Unit
14. Heating systems
a. Electric Strip Heat
b. Electric Strip Heat
c. Electric Heat Pump
16. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
' I
with t Florida Energy Efficiency Code for Building
gy s ing features which will be installed (or exceeded)
Oth ise, a new EPL Display Card will be completed
Date: C-f-., -2- 2-2-
City/FL Zip:
Insulation
R=4.1
R=11.0
R=
R=
Insulation
R=30.0
R=
R=
1�7- L '3 L[9 Lt1
Area
4682.00 ft2
360.00 ft2
f?
ft2
Area
3854.00 ft2
ft2
ft2
R W
6 150
6 125
kBtu/hr
Efficiency
35.4
SEER:16.00
18.0
SEER:16.00
17.2
SEER:18.00
kBtu/hr
Efficiency
27.0
COP:1.00
17.0
COPA.00
17.0
HSPF:10.00
Cap: 50 gallons
EF: 0.98
None
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. �il
3/24/2022 5:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Softwar � I age 1 of
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional egulation - Residential Performance Method
Project Name: PATTERSON RESIDENCE
Builder Name:
Street: 15 CROWN COURT
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: DOUG AND TERESA PATTERSON
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or eAsting New (From Plans)
10. Wall Types(5042.0 sqft.) Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior R=4.1 4682.00 ft2
b. Interior Frame -Wood, Interior R=11.0 360.00 ft2
3. Number of units, if multiple family 1
c. N/A R= ft2
4. Number of Bedrooms 4
d. N/A R= ft2
11. Ceiling Types (3854.0 sqft.) Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented) R=30.0 3854.00 ft 2
6. Conditioned floor area above grade (ft2) 3854
b. N/A R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A R= ft2
7. Windows(1047.9 sqft.) Description Area
12. Ducts R ft2
a. Sup: Attic, Ret: Attic, AH: Attic 6 150
a. U-Factor: Sgl, U=0.65 767.92 ft2
b. Sup: Attic, Ret: Attic, AH: MECH RM 6 125
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65 280.00 ft2
13. Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit 35.4 SEER:16.00
c. U-Factor. N/A ft2
b. Central Unit 18.0 SEER:16.00
SHGC:
c. Central Unit 17.2 SEER:18.00
Area Weighted Average Overhang Depth: 3.099 ft.
14. Heating systems kBtu/hr Efficiency
Area Weighted Average SHGC: 0.263
a. Electric Strip Heat 27.0 COP:1.00
b. Electric Strip Heat 17.0 COP:1.00
8. Skylights Area
c. Electric Heat Pump 17.0 HSPF:10.00
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric Cap: 50 gallons
9. Floor Types (3854.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2756.00 ft2
b. Conservation features
b. Raised Floor R=30.0 1098.00 ft2
None
c. N/A R= ft2
16. Credits None
Total Proposed Modified �oads:
Glass/Floor Area: 0.272
129.24 PASS
Total Baseline Loads:
i
138.13
I hereby certify that the plans and specifications covered by
Review of the plans and OFSE STATT�
this calculation are in compliance with the Florida Energy
specifications covered by this 1� , ; • -O�„".
Code.
(calculation indicates compliance
,with the Florida Energy Code. ti
PREPARED BY:
Before construction is completed r
DATE: - -QOd
this building will be inspected for 0,
compliance with Section 553.908 *.
I hereby certify that this buildi g, ned, is in com Pliance
the Florida Energy Co
Florida Statutes. �C
OD'
with
WE'D
OWNER/AG NT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater! than 0.030 Qn for whole house.
3/24/2022 5:01 PM EnergyGauge® USA 7.0.00 - FlaRes20201 FBC 7th Edition (2020) Compliant Software Page 1 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
PATTERSON RESIDENCE
Bedrooms:
Building Type:
User
Conditioned Area:
Owner Name:
DOUG AND TERESA PATTE
Total Stories:
# of Units:
1
Worst Case:
Builder Name:
Rotate Angle:
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
Family Type:
Detached
New/Existing:
New (From Plans)
Comment:
Address Type:
Street Address
Lot #
Block/Subdivision:
PlatBook:
Street:
15 CROWN COURT
County.
St. Lucie
City, State, Zip:
FORT PIERCE,
FL,
/
v
Design Location
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
97.% 2.5 % Winter Summer Degree Days Moisture Range
FL, Fort Pierce
FL VERO_BEACH_MUNI
39 90 70 75 299 62 Low
i
BLOCKS
i
Number
Name
Area Volume
1
2
3
AHU 1
AHU 2
MINI SPLIT
2019 22986.5
1098 10980
737 7370
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Name
Area
MASTER BEDROO
375
M W IC
88
M TOILET
28
M BATH
210
LINEN
32
FOYER/GREAT RM
478
KITCHEN/DINING
430
POOL BATH
75
HALL
42
CLST 2
19
LAUNDRY
67
BEDROOM 2
175
STAIRS 2ND FLR
96
LOUNGE
364
BEDROOM 3
154
BATH 3
48
WIC 3
24
BEDROOM 4
226
BATH 4
54
WIC 4
36
Volume
Kitchen
4012.5
No
880
No
280
No
2100
No
320
No
6453
No
5160
Yes
750
No
420
No
190
No
670
No
1750
No
960
No
3640
No
1540
No
480
No
240
No
2260
No
540
No
360
No
)ants
Bedrooms
InfilID
Finished
Cooled
Heated
0
1
1
Yes
Yes
Yes
0
1
No
Yes
Yes
0
1
No
Yes
Yes
0
1
Yes
Yes
Yes
0
1
Yes
Yes .
Yes
0
1
Yes
Yes
Yes
0
1
Yes
Yes
Yes
0
1
Yes
Yes
Yes
0
1
No
Yes
Yes
0
1
Yes
Yes
Yes
0
1
Yes
Yes
Yes
0
1
1
Yes
Yes
Yes
0
1
Yes
Yes
Yes
0
1
Yes
Yes
Yes
0
1
1
Yes
Yes
Yes
0
1
No
Yes
Yes
0
1
No
Yes
Yes
0
1
1
Yes
Yes
Yes
0
1
Yes
Yes
Yes
0
1
Yes
Yes
Yes
3/24/2022 5:01 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 8
FORM R405-2020 INPUT SUMMARY
CHECKLIST REPORT
SPAC
iS
Number Name
Area Volume
Kitchen
Occupants
Bedrooms
InfilID Finished
Cooled
Heated
21 MECH RM
96 960
No
0
1 Yes
Yes
Yes
22 GARAGE AREA
737 7370
No
0
1 Yes
Yes
Yes
FLOO�S
# Floor Type
Space
Perimeter Perimeter
R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO
59 ft
375 ft'
____
1
0
0
2 Slab -On -Grade Edge Insulation
M WIC
1 ft
88 ft'
____
1
0
0
3 Slab -On -Grade Edge Insulation
M TOILET
1 ft
28 ft'
____
1
0
0
4 Slab -On -Grade Edge Insulation
M BATH
23.3 ft
210 ft'
____
1
0
0
5 Slab -On -Grade Edge Insulation
LINEN
4 ft
32 ft'
____
1
0
0
6 Slab -On -Grade Edge Insulation
FOYER/GREAT R
49 ft
478 ft'
____
1
0
0
7 Slab -On -Grade Edge Insulation
KITCHEN/DININ
I
26.8 ft
430 ft'
____
1
0
0
8 Slab -On -Grade Edge Insulation
POOL BATH
I
7.8 ft
75 ft'
____
1
0
0
9 Slab -On -Grade Edge Insulation
HALL
1 ft
42 ft'
____
1
0
0
10SIab-On-Grade Edge Insulation
CLST 2
I
3.6 ft
19 ft'
____
1
0
0
11Slab-On-Grade Edge Insulation
LAUNDRY
10.6 ft
67 ft'
____
1
0
0
12SIab-On-Grade Edge Insulation
BEDROOM 2
24.8 ft
175 ft'
____
1
0
0
13Raised Floor
STAIRS 2ND FLR
____ ____
96 ft'
30
1
0
0
14Raised Floor
LOUNGE
____ ____
364 ft'
30
1
0
0
15Raised Floor
BEDROOM 3
154 ft'
30
1
0
0
16Raised Floor
BATH 3
____
48 ft'
30
1
0
0
17Raised Floor
WIC 3
____ ____
24 ft'
30
1
0
0
18Raised Floor
BEDROOM 4
____ ____
226 ft'
30
1
0
0
19Raised Floor
BATH 4
____
54 ft'
30
1
0
0
20Raised Floor
WIC 4
____
36 ft'
30
1
0
0
21Ralsed Floor
MECH RM
____ ____
96 ft'
30
1
0
0
22SIab-On-Grade Edge Insulation
GARAGE AREA
80.4 ft
737 ft'
____
1
0
0
3/24/2022 5:01 PM EnergyGauge® USA 7.0.00 - FlaRes202OiFBC 7th Edition (2020) Compliant Software Page 3 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST
REPORT
ROOF
Roof
Gable
Roof Red
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 4309 ftz
0 ftz
Light N
0.1
No 0.9
No 30
26.57
ATTIF
V
#
Type Ventilation
Vent Rati(1 in)
Area
RBS
IRCC
1
Full attic Unvented
0
3854 ftz
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) MASTER BEDRO
0
Blown
375 ftz
0.1
Wood
2
Under Attic (Unvented) M W IC
0
Blown
88 ftz
0.1
Wood
3
Under Attic (Unvented) M TOILET
0
Blown
28 ftz
0.1
Wood
4
Under Attic (Unvented) M BATH
0
Blown
210 ftz
0.1
Wood
5
Under Attic (Unvented) LINEN
0
Blown
32ft2
0.1
Wood
6
Under Attic (Unvented) FOYER/GREAT R
0
Blown
478 ftz
0.1
Wood
7
Under Attic (Unvented) KITCHEN/DININ
0
Blown
430 ftz
0.1
Wood
8
Under Attic (Unvented) POOL BATH
0
Blown
75 ftz
0.1
Wood
9
Under Attic (Unvented) HALL
0
Blown
42 ftz
0.1
Wood
10
Under Attic (Unvented) CLST 2
0
Blown
19 ftz
0.1
Wood
11
Under Attic (Unvented) LAUNDRY
0
Blown
67ft2
0.1
Wood
12
Under Attic (Unvented) BEDROOM 2
0
Blown
175 ftz
0.1
Wood
13
Under Attic (Unvented) STAIRS 2ND FLR
0
Blown
96 ftz
0.1
Wood
14
Under Attic (Unvented) LOUNGE
0
Blown
364 ftz
0.1
Wood
15
Under Attic (Unvented) BEDROOM 3
0
Blown
154 ftz
0.1
Wood
16
Under Attic (Unvented) BATH 3
0
Blown
48 ftz
0.1
Wood
17
Under Attic (Unvented) WIC 3
0
Blown
24 ftz
0.1
Wood
18
Under Attic (Unvented) BEDROOM 4
0
Blown
226 ftz
0.1
Wood
19
Under Attic (Unvented) BATH 4
0
Blown
54 ftz
0.1
Wood
20
Under Attic (Unvented) WIC 4
0
Blown
36 ftz
0.1
Wood
21
Under Attic (Unvented) MECH RM
0
Blown
96 ftz
0.1
Wood
22
Under Attic (Unvented) GARAGE AREA
0
Blown
737 ftz
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
1
N
Exterior Concrete Block - Int InsuMASTER BE
4.1 1
0 10 8
10.7 ftz
0
0 0.1
0
2
E
Exterior Concrete Block - Int InsuMASTER BE
4.1 20
0 10 8
213.3 ftz
0
0 0.1
0
3
S
Exterior Concrete Block - Int InsuMASTER BE
4.1 23
0 10 8
245.3 ftz
0
0 0.1
0
4
W
Exterior Concrete Block - Int InsuMASTER BE
4.1 15
0 10 8
160.0 ftz
0
0 0.1
0
5
N
Exterior Concrete Block - Int Insul M BATH
4.1 5
0 10 0
50.0 ftz
0
0 0.1
0
6
W
Exterior Concrete Block - Int Insul M BATH
4.1 12
0 10 0
120.0 ftz
0
0 0.1
0
7
NW
Exterior Concrete Block - Int Insul M BATH
4.1 6
5 10 0
64.2 ftz
0
0 0.1
0
3/24/2022 5:01 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 8
FORM R405-2020 INPUT SUMMARY CHE
IST REPORT
I I / Adjacent 42---- Cavity Width Height Sheathing Framing Solar Below I
8
W
Exterior
Concrete Block- Int Insul LINEN
4.1
14 0
10
0
40.0 f12
0
0
0.1
_ 9
N
Exterior
Concrete Block - Int InsuFOYER/GRE
4.1
21 0
13
6
283.5 ft2
0
0
0.1
10
E
Exterior
Concrete Block - Int InsuFOYER/GRE
4.1
0
13
6
27.0 ft2
0
0
0.1
11
S
Exterior
Concrete Block - Int InsuFOYER/GRE
4.1
21 0
13
6
283.5 ft2
0
0
0.1
12
W
Exterior
Concrete Block - Int InsuFOYER/GRE
4.1
5 0
13
6
67.5 ft2
0
0
0.1
13
N
Exterior
Concrete Block - Int InsuKITCHEN/DI
4.1
6 0
12
0
72.0 ft2
0
0
0.1
14
SE
Exterior
Concrete Block - Int InsuKITCHEN/DI
4.1
2 10
12
0
34.0 ft2
0
0
0.1
15
S
Exterior
Concrete Block - Int InsuKITCHEN/DI
4.1
16 0
12
0
192.0 ft2
0
0
0.1
16
W
Exterior
Concrete Block - Int InsuKITCHEN/DI
4.1
2 0
12
0
24.0 ft2
0
0
0.1
17
SE
Exterior
Concrete Block - Int InsuPOOL BATH
4.1
7 10
10
0
78.3 ft2
0
0
0.1
18
SE
Exterior
Concrete Block- Int Insul CLST 2
4.1
3 7
10
0
35.8 ft2
0
0
0.1
_ 19
SE
Exterior
Concrete Block - Int Insul LAUNDRY
4.1
10 8
10
0
106.7 f12
0
0
0.1
20
NE
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1
2 0
10
0
120.0 ft2
0
0
0.1
21
SE
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1
2 9
10
0
127.5 f12
0
0
0.1
22
N
Exterior
Concrete Block - Int InsL$TAIRS 2ND
4.1
12 0
10
0
120.0 ft2
0
0
0.1
23
W
Exterior
Concrete Block - Int Insu£TAIRS 2ND
4.1
8 0
10
0
80.0 ft2
0
0
0.1
24
N
Exterior
Concrete Block - Int Insul LOUNGE
4.1
29 0
10
0
290.0 ft2
0
0
0.1
25
E
Exterior
Concrete Block - Int Insul LOUNGE
4.1
2 0
10
0
20.0 ft2
0
0
0.1
S
Exterior
Concrete Block - Int Insul LOUNGE
4.1
0
10
0
130.0 ft2
0
0
0.1
=26
27
W
Exterior
Concrete Block - Int Insul LOUNGE
4.1
13
8 0
10
0
80.0 ft2
0
0
0.1
S
Exterior
Concrete Block- Int InsuBEDROOM 3
4.1
0
10
0
120.0 f12
0
0
0.1
=28
29
W
Exterior
Concrete Block - Int InsuBEDROOM 3
4.1
12
2 0
10
0
20.0 ft2
0
0
0.1
30
E
Exterior
Concrete Block - Int InsuBEDROOM 4
4.1
12 0
10
0
120.0 ft2
0
0
0.1
31
SE
Exterior
Concrete Block - Int InsuBEDROOM 4
4.1
4 3
10
0
42.5 f12
0
0
0.1
32
S
Exterior
Concrete Block - Int InsuBEDROOM 4
4.1
11 0
10
0
110.0 ft2
0
0
0.1
33
N
Exterior
Concrete Block - Int Insul BATH 4
4.1
6 0
10
0
60.0 ft2
0
0
0.1
34
E
Exterior
Concrete Block - Int Insul BATH 4
4.1
9 0
10
0
90.0 ft2
0
0
0.1
35
N
Exterior
Concrete Block- Int Insul WIC 4
4.1
4 0
10
0
40.0 ft2
0
0
0.1
36
S
Exterior
Concrete Block - Int Insul MECH RM
4.1
12 0
10
0
120.0 f12
0
0
0.1
37
W
Exterior
Concrete Block - Int Insul MECH RM
4.1
8 0
10
0
80.0 ft2
0
0
0.1
38
N
Exterior
Concrete Block - Int InsuGARAGE AR
4.1
25 0
10
0
250.0 ft2
0
0
0.1
39
NE
Exterior
Concrete Block - Int InsuGARAGE AR
4.1 19
5
10
0
94.2 ft2
0
0
0.1
_ 40
E
Exterior
Concrete Block - Int InsuGARAGE AR
4.1 I14
0
10
0
140.0 f12
0
0
0.1
41
W
Exterior
Concrete Block - Int InsuGARAGE AR
4.1
32 0
10
0
320.0 ft2
0
0
0.1
42
SE
' BEDROO
Interior Frame - Wood GARAGE AR
11
14 0
10
0
140.0 ft2
0
0
0.1
43
N
SEDROO
Interior Frame - Wood GARAGE AR
11
2 0
10
0
20.0 ft2
0
0
0.1
44
N
HALL
Interior Frame- Wood GARAGE AR
11
6 0
10
0
60.0 ft2
0
0
0.1
45
N
KITCHEN
Interior Frame - Wood GARAGE AR
11
14 0
10
0
140.0 ft2
0
0
0.1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
3/24/2022 5:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 8
S
V # Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 W Insulated GARAGE AR None .17 24 8 192 ft2
2 W Insulated GARAGE AR None .17 8 8 64 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
#
Ornt
ID
Frame
Panes
NFRC
U-Factor
SHGC
Imp
Area
Depth
Separatic
_ 1
S
3
Vinyl
Low-E Single
Yes
0.65
0.25
Y
36.0 ft2
1 ft 0 in
1 ft 4 in
_ 2
S
3
Metal
Low-E Single
Yes
0.65
013
Y
80.0 ft2
1 ft 0 in
1 ft 4 in
_ 3
W
6
Vinyl
Low-E Single
Yes
0.65
0.25
i
Y
8.0 ft2
1 ft 0 in
1 ft 4 in
4
NW
7
Vinyl
Low-E Single
Yes
0.65
0.25
Y
18.0 ft2
1 ft 0 in
1 ft 4 in
_ 5
N
9
Vinyl
Low-E Single
Yes
0.65
0.25
Y
12.0 ft2
1 ft 0 in
1 ft 4 in
_ 6
N
9
Vinyl
Low-E Single
Yes
0.65
0.25
Y
12.0 ft2
1 ft 0 In
1 ft 4 in
_ 7
N
9
Vinyl
Low-E Single
Yes
0.65
0.25
Y
48.0 ft2
1 ft 0 in
1 ft 4 in
8
N
9
Vinyl
Low-E Single
Yes
0.65
0.25
Y
52.0 ft2
1 ft 0 in
1 ft 4 in
_
_ 9
S
11
Metal
Low-E Single
Yes
0.65
013
Y
200.0 ft2
12 ft 0 in
1 ft 4 in
10
N
13
Vinyl
Low-E Single
Yes
0.65
0.25
Y
8.0 ft2
1 ft 0 in
1 ft 4 in
_ 11
N
13
Vinyl
Low-E Single
Yes
0.65
0.25
Y
16.0 ft2
1 ft 0 in
1 ft 4 in
12
S
15
Vinyl
Low-E Single
Yes
0.65
0.I2I5
Y
72.0 ft2
1 ft 0 in
1 ft 4 in
13
SE
17
Vinyl
Low-E Single
Yes
0.65
0.I�15
Y
5.8 ft2
1 ft 0 in
1 ft 4 in
14
SE
19
Vinyl
Low-E Single
Yes
0.65
0.¢5
Y
23.3 ft2
1 ft 0 in
1 ft 4 in
15
SE
21
Vinyl
Low-E Single
Yes
0.65
0 25
Y
25.0 ft'
1 ft 0 in
1 ft 4 in
_ 16
N
22
Vinyl
Low-E Single
Yes
0.65
0. 5
Y
12.0 ft2
1 ft 0 in
1 ft 4 in
17
N
22
Vinyl
Low-E Single
Yes
0.65
0.1 5
Y
16.0 ft2
1 ft 0 in
1 ft 4 in
18
N
22
Vinyl
Low-E Single
Yes
0.65
0.25
Y
20.0 ftZ
1 ft 0 in
1 ft 4 in
_ 19
N
24
Vinyl
Low-E Single
Yes
0.65
0, 5
Y
36.0 ft2
1 ft 0 in
1 ft 4 in
20
N
24
Vinyl
Low-E Single
Yes
0.65
0.25
Y
108.0 ft2
1 ft 0 in
1 ft 4 in
_ 21
S
26
Vinyl
Low-E Single
Yes
0.65
01125
Y
54.0 ft2
1 ft 0 in
1 ft 4 in
_ 22
S
28
Vinyl
Low-E Single
Yes
0.65
0�25
Y
15.0 ft2
1 ft 0 in
1 ft 4 in
23
S
28
Vinyl
Low-E Single
Yes
0.65
025
Y
36.0 ft2
1 ft 0 in
1 ft 4 in
24
SE
31
Vinyl
Low-E Single
Yes
0.65
0�25
Y
17.5 ft2
1 ft 0 in
1 ft 4 in
25
S
32
Vinyl
Low-E Single
Yes
0.65
0,25
Y
36.0 ft2
1 ft 0 in
1 ft 4 in
_
_ 26
N
33
Vinyl
Low-E Single
Yes
0.65
0125
Y
4.0 ft2
1 ft 0 in
1 ft 4 in
27
N
35
Vinyl
Low-E Single
Yes
0.65
0125
Y
4.0 ft2
1 ft 0 in
1 ft 4 in
28
N
38
Vinyl
Low-E Single
Yes
0.65
0125
Y
12.0 ft2
1 ft 0 in
1 ft 4 in
29
N
38
Vinyl
Low-E Single
Yes
0.65
0.25
Y
40.0 ft2
1 ft 0 in
1 ft 4 in
_ 30
E
40
Vinyl
Low-E Single
Yes
0.65
0:25
Y
21.3 ft2
1 ft 0 in
1 ft 4 in
Int Shade Screeninc
None
None
None
None
None
None
None
None
Drapes/blinds
Exterior 5
Drapes/blinds
Exterior 5
Drapes/blinds
Exterior 5
Drapes/blinds
Exterior 5
Drapes/blinds
Exterior 5
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
3/24/2022 5:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
I
Page 6 of 8
FORM R405-2020 INPUT SUMMARY
CHECKLIST REPORT
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA
EgLA ACH ACH 50
1 Wholehouse
ProposedACH(50)
.000341
3444.6 1881.98
354.79 .1339 5
HEATING S�STEM
#
System Type
Subtype
Speed
Efficiency Capacity
Block
Ducts
1
2
3
Electric Strip Heat/
Electric Strip Heat/
Electric Heat Pump/
None
None
Split
Single
COP:1 27 kBtu/hr
COP:1 17 kBtu/hr
HSPF:10 17 kBtu/hr
1
2
3
sys#1
sys#2
Ductless
COOLING S�STEM
#
System Type
Subtype
Subtype I
Efficiency Capacity Air Flow SHR
Block
Ducts
1
2
3
Central Unit/
Central Unit/
Central Unit/
Split
Split
Split
Single SEER: 16 35.4 kBtu/hr 1062 cfm 0.8
Single SEER: 16 18 kBtulhr 540 cfm 0.8
Single SEER: 18 17.2 kBtu/hr 516 cfm 0.8
I
1
2
3
sys#1
sys#2
Ductless
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
GARAGE AREA.98 51 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
I
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ftz
DUCTS
I
V #
-- Supply --
Location R-Value Area
--- Return --
Location Area Leakage
Air CFM 25 CFM25
Type Handler TOT OUT QN
RLF
HVAC #
Heat Cool
1
2
Attic 6 150 ftz
Attic 6 125 ft'
Attic
Attic
15 ft' Prop.
13 ftz Prop.
Leak Free Attic - - cfm 60.6 cfm 0.03
Leak Free MECH RM -- cfm 32.9 cfm 0.03
0.50
0.50
1 1
2 2
3/24/2022 5:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7ith Edition (2020) Compliant Software Page 7 of 8
FORM R405-2020 INPUT SUMMARY CHEC LIST REPORT
TEMPERA
CURES
Programable Thermostat:
N
Ceiling Fans:
CoolingJan
HeatinJan
Feb
Feb
Mar
Mar
Apr
f Apr
f
May
May
[ Jun
Jun
[X] Jul
[ ] Jul
[X] Auge
j ] Au4
Sep
[ ] Oct [ j
[ ] Oct [X]
Nov
Nov
Dec
Dec
VentingJan
Feb
Mar
[X] A r
[
May
E Jun
[ ]Jul
[ ] Aug
[
Se
[X] Oct [X]
Nov
Dec
Thermostat Schedule: HERS
2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (W D)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
i
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GREAT RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STUDY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 lbs/sq.ft,
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
ENTRY HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STORAGE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8lbs/sq.ft,
ft2
ft
0.3
POWDER RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/s .ft.
ft2
ft
0.3
GARAGE STORAG
3/24/2022 5:01 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 8 of 8
2020 - AIR BARRIER AND INSULATION INSPECTION CI MPONENT CRITERIA
TABLE 402AA A
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a
Project Name: PATTERSON RESIDENCE
Builder Name:
Street: 15 CROWN COURT
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Y
U
Owner: DOUG AND TERESA PATTERSON
Jurisdiction: ST LUCIE COUNTY
m
Design Location: FL, Fort Pierce
0
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air Barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned
with the
Ceiling/attic
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed,
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls
shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
I
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of i
�sulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered,with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
i
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub -floor, wall covering or ceiling
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. in addition, inspection or iog waus snau oe in accordance with the provisions of 1GG-400.
3/24/2022 5:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1