Loading...
HomeMy WebLinkAboutEPL Display CardFORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD RECENED ESTIMATED ENERGY PERFORMANCE INDEX* = 94 APR 0 5 2022 The lower the EnergyPerformance Index, the more efficient the home. St. Lucie County Permitting 1, New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.30 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. Raised Floor c. N/A I certify that this home has com Construction through the abo e in this home before final in ec based on installed Code Dli Builder Signature: Address of New Home: 15 CROWN COURT, F,'ORT PIERCE, FL, New (From Plans) Detached 1 4 No 3854 Area 767.92 ft2 280.00 ft2 ft2 ft2 3.099 ft. 0.263 Area ft2 Insulation Area R=0.0 2756.00 ft2 R=30.0 1098.00 ft2 R= ft2 10. Wall Type and Insulation a. Concrete Block - Int Insul, Exterior b. Interior Frame - Wood, Interior c. N/A d. N/A 11. Ceiling Type and insulation level a. Roof Deck (Unvented) b. N/A c. N/A j 12. Ducts, location & insulation level a. Sup: Attic, Ret: Attic, AH: Attic b. Sup: Attic, Ret: Attic, AH: MECH RM 13. Cooling systems a. Central Unit b. Central Unit c. Central Unit 14. Heating systems a. Electric Strip Heat b. Electric Strip Heat c. Electric Heat Pump 16. Hot water systems a. Electric b. Conservation features None Credits (Performance method) ' I with t Florida Energy Efficiency Code for Building gy s ing features which will be installed (or exceeded) Oth ise, a new EPL Display Card will be completed Date: C-f-., -2- 2-2- City/FL Zip: Insulation R=4.1 R=11.0 R= R= Insulation R=30.0 R= R= 1�7- L '3 L[9 Lt1 Area 4682.00 ft2 360.00 ft2 f? ft2 Area 3854.00 ft2 ft2 ft2 R W 6 150 6 125 kBtu/hr Efficiency 35.4 SEER:16.00 18.0 SEER:16.00 17.2 SEER:18.00 kBtu/hr Efficiency 27.0 COP:1.00 17.0 COPA.00 17.0 HSPF:10.00 Cap: 50 gallons EF: 0.98 None *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. �il 3/24/2022 5:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Softwar � I age 1 of FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional egulation - Residential Performance Method Project Name: PATTERSON RESIDENCE Builder Name: Street: 15 CROWN COURT Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: DOUG AND TERESA PATTERSON Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or eAsting New (From Plans) 10. Wall Types(5042.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 4682.00 ft2 b. Interior Frame -Wood, Interior R=11.0 360.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11. Ceiling Types (3854.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=30.0 3854.00 ft 2 6. Conditioned floor area above grade (ft2) 3854 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(1047.9 sqft.) Description Area 12. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 150 a. U-Factor: Sgl, U=0.65 767.92 ft2 b. Sup: Attic, Ret: Attic, AH: MECH RM 6 125 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 280.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 35.4 SEER:16.00 c. U-Factor. N/A ft2 b. Central Unit 18.0 SEER:16.00 SHGC: c. Central Unit 17.2 SEER:18.00 Area Weighted Average Overhang Depth: 3.099 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.263 a. Electric Strip Heat 27.0 COP:1.00 b. Electric Strip Heat 17.0 COP:1.00 8. Skylights Area c. Electric Heat Pump 17.0 HSPF:10.00 c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (3854.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2756.00 ft2 b. Conservation features b. Raised Floor R=30.0 1098.00 ft2 None c. N/A R= ft2 16. Credits None Total Proposed Modified �oads: Glass/Floor Area: 0.272 129.24 PASS Total Baseline Loads: i 138.13 I hereby certify that the plans and specifications covered by Review of the plans and OFSE STATT� this calculation are in compliance with the Florida Energy specifications covered by this 1� , ; • -O�„". Code. (calculation indicates compliance ,with the Florida Energy Code. ti PREPARED BY: Before construction is completed r DATE: - -QOd this building will be inspected for 0, compliance with Section 553.908 *. I hereby certify that this buildi g, ned, is in com Pliance the Florida Energy Co Florida Statutes. �C OD' with WE'D OWNER/AG NT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater! than 0.030 Qn for whole house. 3/24/2022 5:01 PM EnergyGauge® USA 7.0.00 - FlaRes20201 FBC 7th Edition (2020) Compliant Software Page 1 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: PATTERSON RESIDENCE Bedrooms: Building Type: User Conditioned Area: Owner Name: DOUG AND TERESA PATTE Total Stories: # of Units: 1 Worst Case: Builder Name: Rotate Angle: Permit Office: ST LUCIE COUNTY Cross Ventilation: Jurisdiction: ST LUCIE COUNTY Whole House Fan: Family Type: Detached New/Existing: New (From Plans) Comment: Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 15 CROWN COURT County. St. Lucie City, State, Zip: FORT PIERCE, FL, / v Design Location TMY Site Design Temp Int Design Temp Heating Design Daily Temp 97.% 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low i BLOCKS i Number Name Area Volume 1 2 3 AHU 1 AHU 2 MINI SPLIT 2019 22986.5 1098 10980 737 7370 Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Name Area MASTER BEDROO 375 M W IC 88 M TOILET 28 M BATH 210 LINEN 32 FOYER/GREAT RM 478 KITCHEN/DINING 430 POOL BATH 75 HALL 42 CLST 2 19 LAUNDRY 67 BEDROOM 2 175 STAIRS 2ND FLR 96 LOUNGE 364 BEDROOM 3 154 BATH 3 48 WIC 3 24 BEDROOM 4 226 BATH 4 54 WIC 4 36 Volume Kitchen 4012.5 No 880 No 280 No 2100 No 320 No 6453 No 5160 Yes 750 No 420 No 190 No 670 No 1750 No 960 No 3640 No 1540 No 480 No 240 No 2260 No 540 No 360 No )ants Bedrooms InfilID Finished Cooled Heated 0 1 1 Yes Yes Yes 0 1 No Yes Yes 0 1 No Yes Yes 0 1 Yes Yes Yes 0 1 Yes Yes . Yes 0 1 Yes Yes Yes 0 1 Yes Yes Yes 0 1 Yes Yes Yes 0 1 No Yes Yes 0 1 Yes Yes Yes 0 1 Yes Yes Yes 0 1 1 Yes Yes Yes 0 1 Yes Yes Yes 0 1 Yes Yes Yes 0 1 1 Yes Yes Yes 0 1 No Yes Yes 0 1 No Yes Yes 0 1 1 Yes Yes Yes 0 1 Yes Yes Yes 0 1 Yes Yes Yes 3/24/2022 5:01 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SPAC iS Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 21 MECH RM 96 960 No 0 1 Yes Yes Yes 22 GARAGE AREA 737 7370 No 0 1 Yes Yes Yes FLOO�S # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 59 ft 375 ft' ____ 1 0 0 2 Slab -On -Grade Edge Insulation M WIC 1 ft 88 ft' ____ 1 0 0 3 Slab -On -Grade Edge Insulation M TOILET 1 ft 28 ft' ____ 1 0 0 4 Slab -On -Grade Edge Insulation M BATH 23.3 ft 210 ft' ____ 1 0 0 5 Slab -On -Grade Edge Insulation LINEN 4 ft 32 ft' ____ 1 0 0 6 Slab -On -Grade Edge Insulation FOYER/GREAT R 49 ft 478 ft' ____ 1 0 0 7 Slab -On -Grade Edge Insulation KITCHEN/DININ I 26.8 ft 430 ft' ____ 1 0 0 8 Slab -On -Grade Edge Insulation POOL BATH I 7.8 ft 75 ft' ____ 1 0 0 9 Slab -On -Grade Edge Insulation HALL 1 ft 42 ft' ____ 1 0 0 10SIab-On-Grade Edge Insulation CLST 2 I 3.6 ft 19 ft' ____ 1 0 0 11Slab-On-Grade Edge Insulation LAUNDRY 10.6 ft 67 ft' ____ 1 0 0 12SIab-On-Grade Edge Insulation BEDROOM 2 24.8 ft 175 ft' ____ 1 0 0 13Raised Floor STAIRS 2ND FLR ____ ____ 96 ft' 30 1 0 0 14Raised Floor LOUNGE ____ ____ 364 ft' 30 1 0 0 15Raised Floor BEDROOM 3 154 ft' 30 1 0 0 16Raised Floor BATH 3 ____ 48 ft' 30 1 0 0 17Raised Floor WIC 3 ____ ____ 24 ft' 30 1 0 0 18Raised Floor BEDROOM 4 ____ ____ 226 ft' 30 1 0 0 19Raised Floor BATH 4 ____ 54 ft' 30 1 0 0 20Raised Floor WIC 4 ____ 36 ft' 30 1 0 0 21Ralsed Floor MECH RM ____ ____ 96 ft' 30 1 0 0 22SIab-On-Grade Edge Insulation GARAGE AREA 80.4 ft 737 ft' ____ 1 0 0 3/24/2022 5:01 PM EnergyGauge® USA 7.0.00 - FlaRes202OiFBC 7th Edition (2020) Compliant Software Page 3 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 4309 ftz 0 ftz Light N 0.1 No 0.9 No 30 26.57 ATTIF V # Type Ventilation Vent Rati(1 in) Area RBS IRCC 1 Full attic Unvented 0 3854 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MASTER BEDRO 0 Blown 375 ftz 0.1 Wood 2 Under Attic (Unvented) M W IC 0 Blown 88 ftz 0.1 Wood 3 Under Attic (Unvented) M TOILET 0 Blown 28 ftz 0.1 Wood 4 Under Attic (Unvented) M BATH 0 Blown 210 ftz 0.1 Wood 5 Under Attic (Unvented) LINEN 0 Blown 32ft2 0.1 Wood 6 Under Attic (Unvented) FOYER/GREAT R 0 Blown 478 ftz 0.1 Wood 7 Under Attic (Unvented) KITCHEN/DININ 0 Blown 430 ftz 0.1 Wood 8 Under Attic (Unvented) POOL BATH 0 Blown 75 ftz 0.1 Wood 9 Under Attic (Unvented) HALL 0 Blown 42 ftz 0.1 Wood 10 Under Attic (Unvented) CLST 2 0 Blown 19 ftz 0.1 Wood 11 Under Attic (Unvented) LAUNDRY 0 Blown 67ft2 0.1 Wood 12 Under Attic (Unvented) BEDROOM 2 0 Blown 175 ftz 0.1 Wood 13 Under Attic (Unvented) STAIRS 2ND FLR 0 Blown 96 ftz 0.1 Wood 14 Under Attic (Unvented) LOUNGE 0 Blown 364 ftz 0.1 Wood 15 Under Attic (Unvented) BEDROOM 3 0 Blown 154 ftz 0.1 Wood 16 Under Attic (Unvented) BATH 3 0 Blown 48 ftz 0.1 Wood 17 Under Attic (Unvented) WIC 3 0 Blown 24 ftz 0.1 Wood 18 Under Attic (Unvented) BEDROOM 4 0 Blown 226 ftz 0.1 Wood 19 Under Attic (Unvented) BATH 4 0 Blown 54 ftz 0.1 Wood 20 Under Attic (Unvented) WIC 4 0 Blown 36 ftz 0.1 Wood 21 Under Attic (Unvented) MECH RM 0 Blown 96 ftz 0.1 Wood 22 Under Attic (Unvented) GARAGE AREA 0 Blown 737 ftz 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Int InsuMASTER BE 4.1 1 0 10 8 10.7 ftz 0 0 0.1 0 2 E Exterior Concrete Block - Int InsuMASTER BE 4.1 20 0 10 8 213.3 ftz 0 0 0.1 0 3 S Exterior Concrete Block - Int InsuMASTER BE 4.1 23 0 10 8 245.3 ftz 0 0 0.1 0 4 W Exterior Concrete Block - Int InsuMASTER BE 4.1 15 0 10 8 160.0 ftz 0 0 0.1 0 5 N Exterior Concrete Block - Int Insul M BATH 4.1 5 0 10 0 50.0 ftz 0 0 0.1 0 6 W Exterior Concrete Block - Int Insul M BATH 4.1 12 0 10 0 120.0 ftz 0 0 0.1 0 7 NW Exterior Concrete Block - Int Insul M BATH 4.1 6 5 10 0 64.2 ftz 0 0 0.1 0 3/24/2022 5:01 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 8 FORM R405-2020 INPUT SUMMARY CHE IST REPORT I I / Adjacent 42---- Cavity Width Height Sheathing Framing Solar Below I 8 W Exterior Concrete Block- Int Insul LINEN 4.1 14 0 10 0 40.0 f12 0 0 0.1 _ 9 N Exterior Concrete Block - Int InsuFOYER/GRE 4.1 21 0 13 6 283.5 ft2 0 0 0.1 10 E Exterior Concrete Block - Int InsuFOYER/GRE 4.1 0 13 6 27.0 ft2 0 0 0.1 11 S Exterior Concrete Block - Int InsuFOYER/GRE 4.1 21 0 13 6 283.5 ft2 0 0 0.1 12 W Exterior Concrete Block - Int InsuFOYER/GRE 4.1 5 0 13 6 67.5 ft2 0 0 0.1 13 N Exterior Concrete Block - Int InsuKITCHEN/DI 4.1 6 0 12 0 72.0 ft2 0 0 0.1 14 SE Exterior Concrete Block - Int InsuKITCHEN/DI 4.1 2 10 12 0 34.0 ft2 0 0 0.1 15 S Exterior Concrete Block - Int InsuKITCHEN/DI 4.1 16 0 12 0 192.0 ft2 0 0 0.1 16 W Exterior Concrete Block - Int InsuKITCHEN/DI 4.1 2 0 12 0 24.0 ft2 0 0 0.1 17 SE Exterior Concrete Block - Int InsuPOOL BATH 4.1 7 10 10 0 78.3 ft2 0 0 0.1 18 SE Exterior Concrete Block- Int Insul CLST 2 4.1 3 7 10 0 35.8 ft2 0 0 0.1 _ 19 SE Exterior Concrete Block - Int Insul LAUNDRY 4.1 10 8 10 0 106.7 f12 0 0 0.1 20 NE Exterior Concrete Block - Int InsuBEDROOM 2 4.1 2 0 10 0 120.0 ft2 0 0 0.1 21 SE Exterior Concrete Block - Int InsuBEDROOM 2 4.1 2 9 10 0 127.5 f12 0 0 0.1 22 N Exterior Concrete Block - Int InsL$TAIRS 2ND 4.1 12 0 10 0 120.0 ft2 0 0 0.1 23 W Exterior Concrete Block - Int Insu£TAIRS 2ND 4.1 8 0 10 0 80.0 ft2 0 0 0.1 24 N Exterior Concrete Block - Int Insul LOUNGE 4.1 29 0 10 0 290.0 ft2 0 0 0.1 25 E Exterior Concrete Block - Int Insul LOUNGE 4.1 2 0 10 0 20.0 ft2 0 0 0.1 S Exterior Concrete Block - Int Insul LOUNGE 4.1 0 10 0 130.0 ft2 0 0 0.1 =26 27 W Exterior Concrete Block - Int Insul LOUNGE 4.1 13 8 0 10 0 80.0 ft2 0 0 0.1 S Exterior Concrete Block- Int InsuBEDROOM 3 4.1 0 10 0 120.0 f12 0 0 0.1 =28 29 W Exterior Concrete Block - Int InsuBEDROOM 3 4.1 12 2 0 10 0 20.0 ft2 0 0 0.1 30 E Exterior Concrete Block - Int InsuBEDROOM 4 4.1 12 0 10 0 120.0 ft2 0 0 0.1 31 SE Exterior Concrete Block - Int InsuBEDROOM 4 4.1 4 3 10 0 42.5 f12 0 0 0.1 32 S Exterior Concrete Block - Int InsuBEDROOM 4 4.1 11 0 10 0 110.0 ft2 0 0 0.1 33 N Exterior Concrete Block - Int Insul BATH 4 4.1 6 0 10 0 60.0 ft2 0 0 0.1 34 E Exterior Concrete Block - Int Insul BATH 4 4.1 9 0 10 0 90.0 ft2 0 0 0.1 35 N Exterior Concrete Block- Int Insul WIC 4 4.1 4 0 10 0 40.0 ft2 0 0 0.1 36 S Exterior Concrete Block - Int Insul MECH RM 4.1 12 0 10 0 120.0 f12 0 0 0.1 37 W Exterior Concrete Block - Int Insul MECH RM 4.1 8 0 10 0 80.0 ft2 0 0 0.1 38 N Exterior Concrete Block - Int InsuGARAGE AR 4.1 25 0 10 0 250.0 ft2 0 0 0.1 39 NE Exterior Concrete Block - Int InsuGARAGE AR 4.1 19 5 10 0 94.2 ft2 0 0 0.1 _ 40 E Exterior Concrete Block - Int InsuGARAGE AR 4.1 I14 0 10 0 140.0 f12 0 0 0.1 41 W Exterior Concrete Block - Int InsuGARAGE AR 4.1 32 0 10 0 320.0 ft2 0 0 0.1 42 SE ' BEDROO Interior Frame - Wood GARAGE AR 11 14 0 10 0 140.0 ft2 0 0 0.1 43 N SEDROO Interior Frame - Wood GARAGE AR 11 2 0 10 0 20.0 ft2 0 0 0.1 44 N HALL Interior Frame- Wood GARAGE AR 11 6 0 10 0 60.0 ft2 0 0 0.1 45 N KITCHEN Interior Frame - Wood GARAGE AR 11 14 0 10 0 140.0 ft2 0 0 0.1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3/24/2022 5:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 8 S V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated GARAGE AR None .17 24 8 192 ft2 2 W Insulated GARAGE AR None .17 8 8 64 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separatic _ 1 S 3 Vinyl Low-E Single Yes 0.65 0.25 Y 36.0 ft2 1 ft 0 in 1 ft 4 in _ 2 S 3 Metal Low-E Single Yes 0.65 013 Y 80.0 ft2 1 ft 0 in 1 ft 4 in _ 3 W 6 Vinyl Low-E Single Yes 0.65 0.25 i Y 8.0 ft2 1 ft 0 in 1 ft 4 in 4 NW 7 Vinyl Low-E Single Yes 0.65 0.25 Y 18.0 ft2 1 ft 0 in 1 ft 4 in _ 5 N 9 Vinyl Low-E Single Yes 0.65 0.25 Y 12.0 ft2 1 ft 0 in 1 ft 4 in _ 6 N 9 Vinyl Low-E Single Yes 0.65 0.25 Y 12.0 ft2 1 ft 0 In 1 ft 4 in _ 7 N 9 Vinyl Low-E Single Yes 0.65 0.25 Y 48.0 ft2 1 ft 0 in 1 ft 4 in 8 N 9 Vinyl Low-E Single Yes 0.65 0.25 Y 52.0 ft2 1 ft 0 in 1 ft 4 in _ _ 9 S 11 Metal Low-E Single Yes 0.65 013 Y 200.0 ft2 12 ft 0 in 1 ft 4 in 10 N 13 Vinyl Low-E Single Yes 0.65 0.25 Y 8.0 ft2 1 ft 0 in 1 ft 4 in _ 11 N 13 Vinyl Low-E Single Yes 0.65 0.25 Y 16.0 ft2 1 ft 0 in 1 ft 4 in 12 S 15 Vinyl Low-E Single Yes 0.65 0.I2I5 Y 72.0 ft2 1 ft 0 in 1 ft 4 in 13 SE 17 Vinyl Low-E Single Yes 0.65 0.I�15 Y 5.8 ft2 1 ft 0 in 1 ft 4 in 14 SE 19 Vinyl Low-E Single Yes 0.65 0.¢5 Y 23.3 ft2 1 ft 0 in 1 ft 4 in 15 SE 21 Vinyl Low-E Single Yes 0.65 0 25 Y 25.0 ft' 1 ft 0 in 1 ft 4 in _ 16 N 22 Vinyl Low-E Single Yes 0.65 0. 5 Y 12.0 ft2 1 ft 0 in 1 ft 4 in 17 N 22 Vinyl Low-E Single Yes 0.65 0.1 5 Y 16.0 ft2 1 ft 0 in 1 ft 4 in 18 N 22 Vinyl Low-E Single Yes 0.65 0.25 Y 20.0 ftZ 1 ft 0 in 1 ft 4 in _ 19 N 24 Vinyl Low-E Single Yes 0.65 0, 5 Y 36.0 ft2 1 ft 0 in 1 ft 4 in 20 N 24 Vinyl Low-E Single Yes 0.65 0.25 Y 108.0 ft2 1 ft 0 in 1 ft 4 in _ 21 S 26 Vinyl Low-E Single Yes 0.65 01125 Y 54.0 ft2 1 ft 0 in 1 ft 4 in _ 22 S 28 Vinyl Low-E Single Yes 0.65 0�25 Y 15.0 ft2 1 ft 0 in 1 ft 4 in 23 S 28 Vinyl Low-E Single Yes 0.65 025 Y 36.0 ft2 1 ft 0 in 1 ft 4 in 24 SE 31 Vinyl Low-E Single Yes 0.65 0�25 Y 17.5 ft2 1 ft 0 in 1 ft 4 in 25 S 32 Vinyl Low-E Single Yes 0.65 0,25 Y 36.0 ft2 1 ft 0 in 1 ft 4 in _ _ 26 N 33 Vinyl Low-E Single Yes 0.65 0125 Y 4.0 ft2 1 ft 0 in 1 ft 4 in 27 N 35 Vinyl Low-E Single Yes 0.65 0125 Y 4.0 ft2 1 ft 0 in 1 ft 4 in 28 N 38 Vinyl Low-E Single Yes 0.65 0125 Y 12.0 ft2 1 ft 0 in 1 ft 4 in 29 N 38 Vinyl Low-E Single Yes 0.65 0.25 Y 40.0 ft2 1 ft 0 in 1 ft 4 in _ 30 E 40 Vinyl Low-E Single Yes 0.65 0:25 Y 21.3 ft2 1 ft 0 in 1 ft 4 in Int Shade Screeninc None None None None None None None None Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None 3/24/2022 5:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software I Page 6 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000341 3444.6 1881.98 354.79 .1339 5 HEATING S�STEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 2 3 Electric Strip Heat/ Electric Strip Heat/ Electric Heat Pump/ None None Split Single COP:1 27 kBtu/hr COP:1 17 kBtu/hr HSPF:10 17 kBtu/hr 1 2 3 sys#1 sys#2 Ductless COOLING S�STEM # System Type Subtype Subtype I Efficiency Capacity Air Flow SHR Block Ducts 1 2 3 Central Unit/ Central Unit/ Central Unit/ Split Split Split Single SEER: 16 35.4 kBtu/hr 1062 cfm 0.8 Single SEER: 16 18 kBtulhr 540 cfm 0.8 Single SEER: 18 17.2 kBtu/hr 516 cfm 0.8 I 1 2 3 sys#1 sys#2 Ductless HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None GARAGE AREA.98 51 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM I FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftz DUCTS I V # -- Supply -- Location R-Value Area --- Return -- Location Area Leakage Air CFM 25 CFM25 Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 150 ftz Attic 6 125 ft' Attic Attic 15 ft' Prop. 13 ftz Prop. Leak Free Attic - - cfm 60.6 cfm 0.03 Leak Free MECH RM -- cfm 32.9 cfm 0.03 0.50 0.50 1 1 2 2 3/24/2022 5:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7ith Edition (2020) Compliant Software Page 7 of 8 FORM R405-2020 INPUT SUMMARY CHEC LIST REPORT TEMPERA CURES Programable Thermostat: N Ceiling Fans: CoolingJan HeatinJan Feb Feb Mar Mar Apr f Apr f May May [ Jun Jun [X] Jul [ ] Jul [X] Auge j ] Au4 Sep [ ] Oct [ j [ ] Oct [X] Nov Nov Dec Dec VentingJan Feb Mar [X] A r [ May E Jun [ ]Jul [ ] Aug [ Se [X] Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS i Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT RM Default(8 Ibs/sq.ft. ft2 ft 0.3 STUDY Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 lbs/sq.ft, ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 ENTRY HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 STORAGE Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8lbs/sq.ft, ft2 ft 0.3 POWDER RM Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/s .ft. ft2 ft 0.3 GARAGE STORAG 3/24/2022 5:01 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 8 of 8 2020 - AIR BARRIER AND INSULATION INSPECTION CI MPONENT CRITERIA TABLE 402AA A AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a Project Name: PATTERSON RESIDENCE Builder Name: Street: 15 CROWN COURT Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner: DOUG AND TERESA PATTERSON Jurisdiction: ST LUCIE COUNTY m Design Location: FL, Fort Pierce 0 COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air Barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the Ceiling/attic The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed, shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. I Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of i �sulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered,with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation i readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. in addition, inspection or iog waus snau oe in accordance with the provisions of 1GG-400. 3/24/2022 5:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1