o
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL5259-R31
Revision
2020
Approved
LYGLASS USA
11 W. Newport Center Drive
erfield Beach, FL 33442
i4)233-1330 Ext242
1pert@polyglass.com
iry Alpert
Ipert@polyglass.com
TECH REP
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866)802-8017
uspolyglasstechnical@polyglass.com
QAIREP
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstechnical@polyglass.com
Roofing
UndIerlayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
[ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 1O/21/2022
Validated By John W. Knezevich, PE
El Validation Checklist - Hardcopy Received
Certificate of Independence FL5259 R31 COI 2020 01 COI NIEMINEN.pdf
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4798 2011
ASTM D6163 2015
ASTM D6164 2011
AST i D6222 2011
ASTM D6509
2015
FM 4474
2011
FRSA/TRI, Sixth Edition
2018
UL1897
2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Summary of Products
Method 1 Option D
10/22/2020
101/26/2020
11/01/2020
12/15/2020
12/21/2020
FL #
Model, Number or
Description
Name
5259.1
Polyglass Roof
Roofing uiderlayments
Underlayments
Limits of Use
Approved for use in HVHZ: No
Installation
FL5259 1231
Instructions
II 2020 09 30 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
1131.p f
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified B : Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created b� Independent Third Party: Yes
Other: 1.) The design pressure in this
application relates to one particular
Evaluation Reports
FL5259 R61 AE 2020 09 30 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R31 pfif
underlayment system for use in tile roof
systems. Refer to ER Section 5.8.3 for other
Created b Independent Third Party: Yes
systems and associated maximum design
pressures. 2.) Refer to ER Section 5 for
other limits of use.
Back Next
Contact Us :: 2601 Blair Stone lRoad, Tallahassee FL 32399 Phone: BSO-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013IState of Florida.:: Privacy tatement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
® ® e`ChEcL E
CreditCard
sccurit} min Iitcs
[z]
NEMO I etc.
Certificate of Authorization #/32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
Polyglass USA, Inc. Evaluation Report P12060.02.09-1127
1111 West Newport Center Drive FL5259-1131
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954) 233-1330 Revision 27: 09/30/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements he Accredited Quality Assurance Agency noted herein and
FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such tir
Assurance or production facility location(s) changes, or Code provis
Evaluation Reports by the named client constitutes agreement to
Quality Assurance or the production facility location(s). NEMO ETC, L
to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) precedl
advertising literature. If any portion of the Evaluation Report is disp
INSPECTION: Upon request, a copy of this entire Evaluation Repor,
distributors and shall be available for inspection at the job site at thi
This Evaluation Report consists of pages 1 through 17.
Prepared by:
,���„u,�l,g1",
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
ie as the named product(s) changes, the referenced Quality
ons that relate to the product(s) change. Acceptance of our
iotify MEMO ETC, LLC of any changes to the product(s), the
.0 requires a complete review of its Evaluation Report relative
d by the words "NEMO I etc. Evaluated" may be displayed in
ayed, then it shall be done in its entirety.
shall be provided to the user by the manufacturer or its
request of the Building Official.
The facsimile seal appearing was authorized by Robert Nieminen, P.E. on
09/30/2020. This does not serve as an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
02019 NEMO ETC, LLC
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced k
following sections of the 71h Edition (2020) Florida Building G
Compliance is subject to the Installation Requirements and Lim
ONEMOletc.
Polyglass USA, Inc., have demonstrated compliance with the
e through testing in accordance with the following Standards.
itions / Conditions of Use set forth herein.
Section
Pro a
Standard
Year,
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1897
2015
1507.1.1
/ R905.1.1
Material standard
ASTM D226
2009
1507.1.1,
1507.2.4, 1507.2.9.2 /
Material standard
ASTM D1970
2015
R905.1.1,
R905.2.8.2
1507.3.3
/ R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
1507.11.2
/ R905.11.2
Material standard
ASTM D6163
2015
1507.11.2
/ R905.11.2
Material standard
ASTM D6164
2011
1507.11.2
/ R905.11.2
Material standard
ASTM D6222
2011
1507.11.2
/ R905.11.2
Material standard
ASTM D6509
2015
TAS 110
Accelerated Weathering ASTM D4798
2011
3. REFERENCES:
Entitv,
Examination.
Reference Date
Entitv
Examination
Reference
Date
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST I6049)
30/90 physicals
PLYG-SC11900.03.17
03/109/2017
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
TAS 103
PLYG-SC12115.08.17
08/08/2017
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
TAS 103
PLYG-SC13035.08.17
10/31/2017
ERD (TST 6049)
ASTM D1970
P5110.04.07-1
04/11/2007
FM (TST 1867)
Wind Uplift
3004091
01/12/2000
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ICC-ES (EVL 2396)
IBC Compliance
ESR-1697
04/01/2019
ERD (TST 6049)
Wind Uplift
P30540.11.09-R1
11/30/2009
M-D (CER 1592)
HVHZ Compliance
NOA 17-0614.22
07/06/2017
ERD (TST 6049)
Tensile Adhesion
P11030.11.09-1
11/30/2009
MTI (TST 2508)
ASTM D4798
JX20H7A
04/01/2008
ERD (TST 6049)
Wind Uplift
P11030.11.09-2
11/30/2009
NEMO (TST 6049)
ASTM D1970
4-PLYG-18-004.03.18
03/29/2018
ERD (TST 6049)
ASTM D4977
P11030.11.09-3
11/30/2009
NEMO (TST 6049)
Wind Uplift
4L-PLYG-18-003.01.19
01/11/2019
ERD (TST 6049)
ASTM D1970
P33360.06.10
06/25/2010
NEMO (TST 6049)
ASTM D6163
4S-PLYG-18-002.01.19-A
01/24/2019
ERD (TST 6049)
TAS 103
P33370.03.11
03/02/2011
NEMO (TST 6049)
ASTM D6222
4S-PLYG-18-002.05.19-C
05/20/2019
ERD (TST 6049)
Tensile Adhesion
P33370.04.11
04/26/2011
NEMO (TSI 6049)
ASTM D1970
4j-PLYG-I9-5SUDL-00.A
09/10/2019
ERD (TST 6049)
ASTM D1970
P37300.10.11
10/19/2011
NEMO (TST 6049)
TAS 103
45-PLYG-18-004.10.19-G
10/08/2019
ERD (TST 6049)
TAS 103
P40390.08.12-1
08/06/2012
NEMO (TST 6049)
TAS 103
45-PLYG-18-004.10.19-1
10/08/2019
ERD (TST 6049)
Tensile Adhesion
P40390.08.12-2
08/07/2012
NEMO (TST 6049)
TAS 103
4S-PLYG-18-004.10.19-L
10/09/2019
ERD (TST 6049)
Tensile Adhesion
C41420.09.12-3
09/11/2012
NEMO (TST 6049)
TAS 103
4j-PLYG-I9-SSUDL-01.A
10/10/2019
ERD (TST 6049)
Wind Uplift
P39680.03.13
03/04/2013
NEMO (TST 6049)
TAS 103
4S-PLYG-18-004.12.19-F
12/18/2019
ERD (TST 6049)
ASTM D1970
P45370.04.13
04/26/2013
NEM0 (TST 6049)
TAS 103
4j-PLYG-I9-SSUDL-02.A
01/02/2020
ERD (TST 6049)
Wind Uplift
P1738.02.07-R2
04/29/2013
NEMO (TST 6049)
ASTM D1970
4S-PLYG-18-004.01.20.H
01/14/2020
ERD (TST 6049)
Wind Uplift
11757.04.01-1-R1 04/30/2013
NEMO (TST 6049)
ASTM D1970
4S-PLYG-18-004.01.20.K
01/14/2020
ERD (TST 6049)
ASTM D6164
P37590.03.13-3A 05/06/2013
NEMO (TST 6049)
TAS 103
4S-PLYG-18-004.01.20.A
01/16/2020
ERD (TST 6049)
ASTM D6509
P37590.03.13-1-R1 06/26/2013
NEMO (TST, 6049)
ASTM D6164
4S-PLYG-18-004.01.20.B
01/16/2020
ERD (TST 6049)
Wind Uplift
P41630.08.13
08/06/2013
NEMO (TST 6049)
ASTM D6222
4S-PLYG-18-002.12.19-K-RI
01/07/2020
ERD (TST 6049)
ASTM D4601
P45940.09.13
09/04/2013
NEM0 (TST 6049)
TAS 103
PLYG-SC15855.05.20.A
05/29/2020
ERD (TST 6049)
Wind Uplift
P11751.05.03-R1
11/26/2013
NEMO (TST 6049)
TAS 103
4j-PLYG-20-SSUDL-01
07/06/2020
ERD (TST 6049)
Wind Uplift
P11781.11.03-R1
11/26/2013
NEMO (TST 6049)
ASTM D6222
4q-PLYG-19-55M8B-05.A
07/23/2020
ERD (TST 6049)
30/90 physicals
P45270.0S.14
05/12/2014
NEMO (TST 6049)
ASTM D4798/1)1623
4j-PLYG-I9-SSUDL-05.A
09/10/2020
ERD (TST 6049) .
Tensile adhesion
6020.09.14-5
09/09/2014
NEMO (TST 6049)
ASTM D1970
4j-PLYG-20-SSUDL-05.A
09/30/2020
ERD (TST 6049)
Tensile adhesion
6020.09.14-6
09/08/2014
NEMO (TST'6049)
TAS 103
4j-PLYG-20-SSUDL-05.0
09/30/2020
ERD (TST 6049)
Tensile adhesion
P46520.10.14
10/03/2014
NEMO (TST 6049)
TAS 103
4J-PLYG-20-SSUDL-11
09/30/2020
NEMO ETC, I.I.C.
Evaluation Report P12060.02.09-1127
Certificate of Authorization #32455
7T" EDITION (2020) FBC NON-HVHZ EVALUATION
FL5259-1131
Polyglass Roof Underlayments
Revision 27: 09/30/2020
Page 2 of 17
Entity
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ONEMOjetc.
'Examination Reference Date: ntlty Examination.,.. Reference Date
ASTM D1970/D4798 P43290.10.14 10/17/2014 PRI (TS+I 5878) Tensile Adhesion PRI01111. 04/08/2002
TAS 103 PLYG-SC7550.03.15 03/24/2015 PRI JTST 5878) TAS 103 PUSA-018-02-01 07/14/2003
Tensile adhesion P40390.04.15 04/03/2015 PRI (TSTI 5878) TAS 103 PUSA-035-02-01 09/29/2006
TAS 103 P44360.10.14-R1 05/18/2015 PRI (TST 5878) TAS 103 PUSA-055-02-02 12/10/2007
Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 PRI ITS 5878) ASTM D6222 PUSA-061-02-02 01/28/2008
ASTM D1970 PLYG-SC10130.06.16-1 06/27/2016 PRI (TS 5878) ASTM D6164 PUSA-088-02-01 07/29/2009
Tensile adhesion PLYG-SC10130.06.16-2 06/27/2016 Polyglass USA PA Affidavit Mule -Hide Cross Ltg 03/01/2008
TAS 103 PLYG-SC10130.06.16-3 06/27/2016 Polyglass USA Materials Affidavit Polystick Compound 08/18/2011
ASTM D1970/D4798 PLYG-SC8080.07.16 07/16/2016 UL (QUA9625) Quality Control Service Confirmation (FL) 09/13/2018
Wind Uplift PLYG-SC12025.10.16 10/12/2016 UL (QUA9625) Quality Control Service Confirmation (TX) 11/07/2019
TAS 103 PLYG-SC13040.12.16 12/27/2016 UL (QUAI9625) Quality Control Florida BCIS Current
DUCT DESCRIPTION:
Product `" Material Standard Plants) v ' Description
Elastobase ASTM D6163 FL I Fiberglass -reinforced, SBS modified bitumen base sheet
Elastobase P ASTM D6164 FL I Polyester -reinforced, SBS modified bitumen base sheet
Elastoflex S6 G ASTM D6164 FL, PA I Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
Elastoflex S6 G FR ASTM D6164 FL I Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt
FRSA/TRI 09-18 waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
Mule -Hide SA-APP Cap Sheet ASTM D6222 FL I Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TR109-18
Mule -Hide SA-APP Cap Sheet ASTM D6222 FL I Polyester -reinforced, APP modified bitumen cap sheet
(FR) FRSA/TR109-18
Polyflex G ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI 09-18 use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened or adhered tile
roof systems
Polyflex G FR ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI 09-18 use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened tile roof systems
Polyflex SA P ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI 09-18
Polyflex SA P FR ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI 09-18
Polyglass Base ASTM D6509 FL Fiberglass -reinforced, APP modified bitumen base sheet
Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass -reinforced, asphaltic base sheet
4. •O
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
NEMO ETC, U.C.
Certificate of Authorization #32455
7- EDITION (2020) FBC NON-HVHZI EVALUATION
Polyglass Roof Underlayments
Evaluation Report P12060.02.09-1127
FL5259-R31
Revision 27: 09/30/2020
Page 3 of 17
DUCT DESCRIPTION:
Product `" Material Standard Plants) v ' Description
Elastobase ASTM D6163 FL I Fiberglass -reinforced, SBS modified bitumen base sheet
Elastobase P ASTM D6164 FL I Polyester -reinforced, SBS modified bitumen base sheet
Elastoflex S6 G ASTM D6164 FL, PA I Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
Elastoflex S6 G FR ASTM D6164 FL I Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt
FRSA/TRI 09-18 waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
Mule -Hide SA-APP Cap Sheet ASTM D6222 FL I Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TR109-18
Mule -Hide SA-APP Cap Sheet ASTM D6222 FL I Polyester -reinforced, APP modified bitumen cap sheet
(FR) FRSA/TR109-18
Polyflex G ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI 09-18 use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened or adhered tile
roof systems
Polyflex G FR ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI 09-18 use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened tile roof systems
Polyflex SA P ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI 09-18
Polyflex SA P FR ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI 09-18
Polyglass Base ASTM D6509 FL Fiberglass -reinforced, APP modified bitumen base sheet
Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass -reinforced, asphaltic base sheet
4. •O
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
NEMO ETC, U.C.
Certificate of Authorization #32455
7- EDITION (2020) FBC NON-HVHZI EVALUATION
Polyglass Roof Underlayments
Evaluation Report P12060.02.09-1127
FL5259-R31
Revision 27: 09/30/2020
Page 3 of 17
4. •O
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
NEMO ETC, U.C.
Certificate of Authorization #32455
7- EDITION (2020) FBC NON-HVHZI EVALUATION
Polyglass Roof Underlayments
Evaluation Report P12060.02.09-1127
FL5259-R31
Revision 27: 09/30/2020
Page 3 of 17
M
4.15
4.16
4.17
4.18
4.19
4.20
4.21
AL 3\\
WNEMO etc.
PRODUCT
Product Material Standard. Plants)
Description'
Polystick IR-Xe
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate
surface
Polystick MTS Plus
ASTM D1970
FL, NV%
Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
PA, T
membrane, glass fiber reinforced, surfaced with
polyolefinic film surface
Polystick MU-X
ASTM D19701
FL, NV, PA
Nominal 54-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polypropylene film surface
'Polystick TU Max
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane with a 190 g/m2 polyester fabric surface
PO lystil a TU P
FRSA/TRI 09-18
FL, PA, TX
Nomina30-mil thick rubberized asphalt waterproofing
membrane, glass-fiber/polyester reinforced, with a
granular surface
Polystick TU Plus
ASTM D1970
FL, PA,
TX
Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane, glass fiber reinforced, with a polyester fabric
surface
Polystick XFR
ASTM D1970
NV, TX�
Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane, glass fiber reinforced, surfaced with a
textured film surface
This is a Building Code Evaluation. Neither NEMO ETC, LLC nor R
any project on which this Evaluation Report, or previous version
retained specifically for that purpose.
)ert Nieminen, P.E. are, in any way, the Designer of Record for
thereof, is/was used for permitting or design guidance unless
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. I Roof decks and structural members shall be in accordance with
FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for 'requirements and limitations concerning the use of foam plastic
insulation.
5.5 Polyglass Roof Underlayments may be used with any prepared 'roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof!covering.
I Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard
laboratory conditions. Agreement between purchaser and seller, as setforth in Section 4;3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R27
Certificote of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27: 09/30/2020
Page 4 of 17