HomeMy WebLinkAboutRevisions-ENERGY CALC, REVISIONS FOR HURRICANE IMPACT RATINGS 4.27.22 a
i
I
OFFICE USE ONLY:
DATE FILED: r „g_ PERMIT#
REVISION FEE: •J RECEIPT# 61
PLANNING& DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
F?E
vi'.'j'sj
FORT PIERCE, FL 34982-5652
(772)462-1553
QP NCA ON FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
o
LOCATION/SITE c `o
ADDRESS:
8521 WATERSTONE BLVD PERMIT 2103-0622
LOT 38/BLK 2M/ATERSTONE
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
ENERGY CALC REVISIONS FOR HURRICANE IMPACT RATINGS
i
I
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CRC13301466 ST. LUCIE CO CERT. #: 29179
BUSINESS NAME: ;,AI,DAMS HOMES OF NORTHWEST FLORIDA, INC.
QUALIFIERS NAME•�WILLIAM BRYAN ADAMS
ADDRESS: 100 WEST GARDEN ST,2ND FLOOR
CITY: PENSACOLA !; STATE: FL ZIP: 32502
PHONE(DAYTIME)! 'l 772-905-8394 FAX: 772-905-8511
OWNER/BUILDER INFORMATION: -
I !
NAME: ADAMS HOMES OF NORTHWEST FLORIDA, INC.
ADDRESS: 100 WESTgGARDEN ST,2ND FLOOR
CITY: PENSACOLA I'd STATE: FL ZIP: 32502 �
PHONE (DAYTIME:!: I772-905-8394 FAX: 772-905-8511
ARCHITECT/ENGINEER INFORMATION:
NAME: KEESEE ASSOCIATES
ADDRESS: 945 SOUTH ORANGE BLOSSOM TRAIL
CITY: APOPKA STATE: FL ZIP: 32703
PHONE(DAYTMM) :1 407-880-2333 FAX:
SLCCC: 9123109
Revised 06130/17
2103 0(, zZ
L. Roberto Lomas P.E. Engineering Evaluation Report
1432 Woodford Rd.
Lewisville NC,27023 Report No.: 513921 B
434-688-0609
rllomas@lrlomaspe.com
Manufacturer: MI Windows & Doors, LLC.
650 West Market Street
Gratz, PA 17030-0370
,I
I .
Product Line: Series 1620 SH impact-52"x 75"
i. a
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61G20-3.005 method 1(a).The product listed
herein complies with requirements of the current Florida Building Code.
Supporting Technical Documentation:
1. Approval documents:drawing numbers 08-03042 Revision B,prepared,signed and sealed by Luis Roberto
Lomas P.E. I.
2. Report No.: G1518.01-109-47 signed by Timothy J. McGill
Architectural Testing, Inc.,York PA.
AAMA/W DMA/CSA 101/I.S.2/A440-08
Design pressure: (, ±50.13psf
Water penetration lresistance 7.52psf
3. Report No.: G1518.02-109-47 signed by Timothy J. McGill
Architectural Testing, Inc.,York PA.
ASTM Ell886-05 a'nd ASTM Ell996-12
ASTM E1886/E1996 Large Missile Impact, Level D,Wind Zone 3
ASTM Ell 886/E1996 Cyclic Load Test,±50.Opsf design pressure
4. Anchor calculations,)report number 513921-1 B, prepared,signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure: ±50.0psf
• Unit size: ii 52 1/8"x 75"
• Units must be glazed per ASTM E1300-04/09,according to glazing details in approval drawing.
• This product is nofrated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection in wind borne debris regions.
• Frame material to be Rigid PVC.
y I
Installation:
Units must be installed in accordance with manufacturer's installation instructions and approval documents,08-03042,
Revision B.
Certification of Independence:
Please note that I don't haveinor will acquire a financial interest in any company manufacturing or distributing the
product(s)for which this report is being issued.Also, I don't have nor will acquire a financial interest in any other entity
involved in the approval process of the listed product(s).
f,
I
� J • EN
'*; �51 •
TAT of .•c��!
iO �I
10NALI ����
1 of 1 Luis R.Lomas,P.E.
FL No.:62514
01/28/2020
' I
I
i I
2—
L. Roberto Lomas PIS. Engineering Evaluation Report
1432 Woodford Rd.
1 Lewisville NC,27023 Report No.: 513921 B
434-688-0609
rllomas@lrlomaspe.com
I
Manufacturer: MI Windows& Doors, LLC.
650 West Market Street
Gratz,PA 17030-0370
i,
it
Product Line: Series 1620 SH Impact-52"x 75"
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation.for Statewide Acceptance per Rule 61G20-3.005 method 1(a).The product listed
herein complies with requirements of the current Florida Building Code.
4
Supporting Technical Documentation:
1. Approval documents:drawing numbers 08-03042 Revision B,prepared,signed and sealed by Luis Roberto
Lomas P.E.
2. Report No.: G1518.01-109-47 signed by Timothy J.McGill
Architectural Testing, Inc.,York PA.
AAMA1WDMA/CSA`101/I.S.2/A440-08
Design pressure: 1, ±50.13psf
Water penetration Fresistance 7.52psf
3. Report No.: G1518.02-109-47 signed by Timothy J.McGill
Architectural Testing, Inc.,York PA.
ASTM El886-05 and ASTM Ell996-12 J" ' " - - J ' `�- - `J
ASTM E1886/E1996 Large Missile Impact, Level D,Wind Zone 3
ASTM El886/E1996 Cyclic Load Test,±50.Opsf design pressure
4. Anchor calculation'sij report number 513921-1 B,prepared,signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use: i
• Maximum design pressure: ±50.0psf
• Unit size: ,i 52 1/8"x 75"
• Units must be glazed per ASTM E1300-04/09,according to glazing details in approval drawing.
• This product is not,rated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection in wind borne debris regions. I
• Frame material to be Rigid PVC.
Installation:
Units must be installed in accordance with manufacturer's installation instructions and approval documents,08-03042,
Revision B.
i,
Certification of Independence:
Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the
product(s)for which this report is being issued.Also, I don't have nor will acquire a financial interest in any other entity
involved in the approval process of the listed product(s).
}
9 �
v• �,�G E N y •d''�
J
1
4- �TgAT;-OF •��I
;/V 0NAL1
1 of 1 Luis R. Lomas,P.E.
FL No.:62514
01/28/2020
i
240b. Oho-2-
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method;
I
Project Name: Lot38Blk2Waterstone2508CRGR Builder Name: Adams Homes
Street: 8521 Waterstone Bolulevard Permit Office: j
City,State,Zip: Fort Pierce, FL,3495j1 Permit Number:
Owner: Jurisdiction: 661000
Design Location: FL,ST LUCIE_CO_INITL County: St.Lucie(Florida Climate Zone 2)
1. New construction or existing 1 I New(From Plans) 10. Wall Typep2047.7 sqft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1748.50 ft2
b.Frame=Wood,Adjacent R=13.0 299.17 ft2 ,
3. Number of units,if multiple family 1 c,N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? ., 11.Ceiling Types (2603.0 sqft.) Insulation Area
No a.Under Attic(Vented) R=30.0 2523.00 ftz
6. Conditioned floor area above grade(ft2); 2523 b.Knee Wall(Vented) R=19.0 80.00 ft2
Conditioned floor area below grade(ft2), 0 c.N/A R= ft2
7. Windows(295.2 sqft.) Description Area 12.Ducts R ft2
a.Sup:Attic,Ret:Main,AH:Main 6 504.6
a. U-Factor: Dbl,U=0.28 •I 161.89 ft2
SHGC: SHGC=0.22
b. U-Factor: Dbl,U=0.28 70.92 ft2 13.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.20 a.Central Unit 42.0 SEER:15.00
c. U-Factor: Dbl,U=0.34 41.56 ft2
SHGC: SHGC=0.22 ! 14.Heating systems kBtu/hr Efficiency
Area Weighted Average Overhang Depth: 6.173 ft.
Area Weighted Average SHGC: I 0.214 a.Electric Heat Pump 42.0 HSPF:8.50
8. Skylights I' Area
c. U-Factor:(AVG) N/A ft2 15.Hot water systems
SHGC(AVG): N/A i; . a.Electric Cap:40 gallons
9. Floor Types (2523.0 sqft.) C Insulation Area EF:0.940
a.Slab-On-Grade Edge Insulation R=0.0 2523.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 16.Credits Pstat i
Glass/Floor Area: 0.117 Total Proposed Modified Loads: 68.36 PASS
jTotal Baseline Loads: 71.02
I
hereby certify that the plans and specif cations covered by Review of the plans and 0 'SIiE ST�g1A
this calculation are in compliance withuthe Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code. '
PREPARED BY: L1A iq Russell Henry Before construction is completed
DATE: April 18, 2022 `� this building will be inspected for i..
compliance with Section 553.908
hereby certify that this building, as designed, is in compliance Florida Statutes. r� 5
with the Florida Energy Code. .'WE
OWNER/AGENT: �I BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification luy the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.75 ACH50(R402.4.1.2).
;I
I
4/18/2022 4:54 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition 1(2020) Compliant Software Page 1 of 5
I
5 '
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Lot38BIk2Waterstone2508CR Bedrooms: 4 Address Type: Lot Information
Building Type: User Conditioned Area: 2523 Lot# 38/2
Owner Name: j Total Stories: 1 Block/Subdivision: Waterstone
#of Units: 1 ! Worst Case: No PlatBook:
Builder Name: Adams Homes �, Rotate Angle: 0 Street: 8521 Waterstone Boule
Permit Office: j` Cross Ventilation: No County: St.Lucie
Jurisdiction: 661000 Whole House Fan: No City,State,Zip: Fort Pierce,
Family Type: Detached I; FL, 34951 ,
New/Existing: New(From Plans)
Comment:
.I
f
ii CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location i ,I MY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,ST_LUCIE_CO_INTL Fl- VERI� 'I IO_BEACH_MUNI 39 90 70 75 299 58 Medium
BLOCKS
Number Name ;j Area Volume
1 Blockl 2523 22202.4
I
SPACES
Number Name ( Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled (Heated
1 Main I2523 22202.4 Yes 5 4 1 Yes Yes iYes
H FLOORS
# Floor Type ,I Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatofi Main 242.9 ft 0 2523 ft2 ---- 0.32 0 0.1 68
ROOF
i
Roof Gable Roof Rad Solar SA Emitt Emitt Deck ! Pitch
V # Type �Materials Area Area Color Barr Absor. Tested Tested Insul. j (deg)
1 Gable or Shed Composition shingles 2821 ft2 630 ft2 Medium N 0.85 N 0.9 No 0 26.57
I� it I
f
ATTIC I
f ,
# Type � , Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic ! Vented 300 2523 ft2 N N
CEILING
# Ceiling Type f Space R-Value Ins Type Area Framing Frac Truss Type
1 Knee Wall(Vented) Main 19 Blown 20 ft2 0.11 Wood
2 Knee Wall(Vented) Main 19 Blown 20 ft2 0.11 Wood
3 Knee Wall(Vented) Main 19 Blown 20 ft2 0.11 Wood
4 Knee Wall(Vented) Main 19 Blown 20 ft2 0.11 Wood
5 Under Attic(Vented) ,i Main 30 Blown 2523 ft2 0.11 Wood
I
4/18/2022 4:54 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 5
I I
I
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
_ 1 NE Exterior Concrete Block-Int Insul Main 4.1 57 3 8 0 458.0 ft2 0 0 0.6 0
_2 E Exterior Concrete Block-Int Insul Main 4.1 4 11 10 0 49.2 ft2 0 0 0.6 0
_3 SE Exterior Concrete Block-Int Insul Main 4.1 61 0 8 0 488.0 ft2 0 0 0.6 0
_4 SW Exterior Concrete Block-Int Insul Main 4.1 57 0 8 0 456.0 ft2 0 0 0.6 0
_5 NW Exterior Concrete Block-Int Insul Main 4.1 37 2 8 0 297.3 ft2 0 0 0.6 0
6 - Garage Frame-Wood Main 13 29 11 10 0 299.2 ft2 0 0.23 0.01 0
I, g
DOORS
# Ornt Door Ty a Space Storms U-Value Width Height Area
Ft In Ft In
1 NE Insulated Main None .25 2 4 6 8 15.6 ft2
2 NW Insulated Main None .25 3 6 8 20 ft2
�I
3 - Wood . Main None .25 2 8 6 8 17.8;ft2
P '
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
i i
1 NE 1 Vinyl Low-E D j ouble Yes 0.28 0.22 Y 9.8 ft2 1 ft 4 in Oft 11 in Drapes/blinds Exterior 5
2 NE 1 Vinyl Low-ElDouble Yes 0.28 0.22 Y 16.2 ft2 1 ft 4 in Oft 11 in Drapes/blinds Exterior 5
3 E 2 Vinyl Low-E Double Yes 0.28 0.22 N 12.5 ft2 12 ft 1 in 0 ft 3 in Drapes/blinds Exti dor 5
4 SE 3 Vinyl Low-E Double Yes 0.34 0.22 N 17.8 ft2 10 ft 2 in 0 ft 7 in None None
5 SE 3 Vinyl Low-E iouble Yes 0.28 0.22 Y 12.5 ft2 7 ft 2 in 0 ft 3 in Drapes/blinds Exterior 5
6 SE 3 Vinyl Low-E Double Yes 0.28 0.22 N 30.0 ft2 10 ft 2 in 0 ft 4 in Drapes/blinds Exterior 5
7 SE 3 Vinyl Low-EII'1 Double Yes 0.28 0.22 N 48.6 ft2 1 ft 4 in 1 ft 2 in Drapes/blinds Exterior 5
8 SW 4 Vinyl Low-EPl ouble Yes 0.34 0.22 N 17.8 ft2 23 ft 8 in 0 ft 7 in None None
9 SW 4 Vinyl Low-EIE ouble Yes 0.28 0.22 N 32.4 ft2 1 ft 4 in Oft 11 in Drapes/blinds Exterior 5
10 NW 5 Vinyl Low-E!j[ouble Yes 0.28 0.2 N 32.4 ft2 7 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5
I, d I
11 NW 5 Vinyl Low-EiDouble Yes 0.28 0.2 N 38.5 ft2 1 ft 4 in 2 ft 10 in Drapes/blinds Exterior 5
12 NW 5 Vinyl Low-E�Double Yes 0.29 0.21 N 7.5 ft2 11 ft 10 in 0 ft 0 in None None
13 NW 5 Vinyl Low-E!Double Yes 0.29 0.21 N 13.3 ft2 11 ft 10 in 2 ft 2 in Drapes/blinds None
14 NW 5 Vinyl Low-E IDouble Yes 0.34 0.22 N 6.0 ft2 1 ft 4 in 1 ft 2 in None None
GARAGE
i
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 620 ft2 620 ft2 72.737 ft 8 ft 1
;I
i
i
I
, I
I'
4/18/2022 4:54 PM EnergyGa I uge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 5
r
I
4
FORM R405-2020 IN IPUT SUMMARY CHECKLIST REPORT
y INFILTRATION
# Scope Method ! SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) 000377 2497.8 137.04 257.27 .1266 6.75
l HEATING SYSTEM
# System Type i! , Subtype Speed Efficiency Capacity Block Ducts
1 Electric Heat Pump/ f Split Singl HSPF:8.5 42 kBtu/hr 1 4s#1
i
j COOLING SYSTEM
# System Type I Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Singl SEER:15 42 kBtu/hr cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubTpe Location EF Cap Use SetPnt Conservation
1 Electric None d Garage 0.94 40 gal 60.9 gal 120 deg None
I, SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF I
i
None None ft' j
j�
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat! Cool
1 Attic 6 504�.6 ft Main 126.15 Default Leakage Main (Default) (Default) 1 j 1
u
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar Apr Ma Jun Jul Auge Oct Nov Dec
Heatin Jan HFeb Ma'r Q
Apr f May Jun Jul Au Sep Oct Nov Dec
Ventin Jan Feb X Mar Apr [ May Jun Jul [ Aug [ Se [X]Oct Nov Dec
I,
I
'N I
I
�I
I
I
i
I ,
li
i
4/18/2022 4:54 PM EnergyG uge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 4 of 5
I
i
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference Hours.
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 ; 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 I; 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
yl
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8 Ibs/s .ft. 0 ft. 0 ft 0.3 Main
I I
I
I ,
I
II ,
i
II ,
I
f, l
I '
'I
,I 4
I
I �
i
I,
I !I ,
i'
5
�I
I >
I .
E i
i
' I
i
I
I I
I I
4 .I
4/18/2022 4:54 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index,the more efficient the home.
i,
8521 Waterstone Boulevard, Fort Pierce, FL, 34951
k
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
�, a.Concrete Block-Int Insul,Exterior R=4.1 1748.50 ft2
2. Single family or multiple family Detached b.Frame-Wood,Adjacent R=13.0 299.17 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
11.Ceiling Type and insulation level Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 2523.00 ft2
6. Conditioned floor area(ft2) I' 2523 b.Knee Wall(Vented) R=19.0 80.00 ft2
7. Windows** Description ;', Area c. N/A R= ft 2
a. U-Factor: Dbl,U=0.28 I' 161.89 ft2 12•Ducts,location&insulation level R ft2
a.Sup:Attic,Ret:Main,AH:Main 6 504.6
SHGC: SHGC=0.22
b. U-Factor: Dbl,U=0.28 70.92 ft2
SHGC: SHGC=0.20 13.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.34 41.56 ft2 a.Central Unit 42.0 SEER:15.00
SHGC: SHGC=0.22 ,j
d. U-Factor: other(see details) 20.83 ft2 j
p 14.Heating systems kBtu/hr Efficiency
SHGC: other(see details) a. Electric Heat Pump 42.0 HSPF:8.50
Area Weighted Average Overhang Depth:' 6.173 ft.
Area Weighted Average SHGC: �I : 0.214
8. Skylights Description Area 15.Hot water systems
a. Electric Cap:40 gallons
a.' U-Factor(AVG): N/A ft2EF:0.94
SHGC(AVG): N/A b. Conservation features
9. Floor Types Insulation Area None
a.Slab-On-Grade Edge Insulation R=0.0 2523.00 ft2 Credits(Performance method) Pstat
b.N/A R= ft2
c. N/A R= ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building ST
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. 10therwise, a new EPL Display Card will be completed ,,,'''%� '{
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: ! City/FL Zip: ,
f,
I
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/18/2022 4:54 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
I
,
, I
r
Zic�3 - (�(oZZ
*�= Job: Lot 38 Block 2 Waterston...
wrightsoft® Manual S Compliance Report Date: NOVEMBER 3,2010
En&6' House By. DCS
I'
Del Alt Heating&Air Conditioning
,i
531 Codisco Way,Sarford,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:wvw cdelair.com Licerse:CAC05147
III
Project I • •
I
For. II Adams Homes'
8521 Waterstone Boulevard,Fort Pierce,FL 34951 j
I,
'i
Cooling Equipment
Design Conditions
Outdoor design DB: 90.40.F Sensible gain: 30293 Btuh Entering coil DB: 76.5°1-
Outdoor design WB: 77AOF '! Latent gain: 5175 Btuh Entering coil WB: 63.3°F
Indoor design DB: 75.0°F Total gain: 35467 Btuh
Indoor RH: 50% Estimated airflow: 1400 ch
Manufacturer's PerformanceiData at Actual Design Conditions
Equipment type: SpIitASHP
{
Manufacturer. Carrier j Model: 25HBC542AP03+FB4CNP048L00
Actual airflow: 1400 cfm
Sensible capacity: 33600 Btt;h 111%of load
Latent capacity: 6637 136 128%of load
Total capacity: 40236 Btuh 113%of load SHR: 84%
Heating Equipment
I. �I
Design Conditions
Outdoor design DB: 41.0°F Heat loss: 31052 Btuh Entering coil DB: 69.5°F
Indoor design DB: 70.0°F
I I
I
Manufacturer's Performance'Data at Actual Design Conditions
Equipmenttype: SpIitASHP
Manufacturer. Carrier 'I'll Model: 25HBC542AP03+FB4CNP048L00
Actual airflow: 1400 Z,
Output capacity. 38491 Btuh 124%of load Capacity balance: 33 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer. i '1 Model:
Actual airflow: 1400 c6
Output capacity: 8.3 kW 91%of load Temp.rise: 18 OF
Meets all requirements ofACCA Manual S.
' I
-FP- wrightsoft"
�; 2022-Apr-1816:58:15
Riga Sine®Uriversa12021 21.0.07 RSU24015
q Page 1
ACCA ...erstore2508CRGR\L.t38BIIQWaterstore2508CRGRrtp Calc=MJ8 Hasefaces:NW
I
I
' I+ i
Corn Illonent Constructions Job: Lot 38 Block 2 waterstone...
- wrightsoft® II Date: NOVEMBER 3,2010
Endi; House By, DCs
Del Air Heating &Air Conditioning
I
531 Codisco Way,Sardord,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:wwwdelair.com Licerse:CAC05147
Iltl �
Project
For. Adams Homes i
8521 Waterstone Boulevard,Fort Pierce,FL34951
I'
Design Conditions
Location: i' Indoor: Heating Cooling
St Lude Co Intl,FL,US Indoor temperature(°F) 70 75
Elevation: 26 ft Design,TD(°F) 29 15
Latitude: 280N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(grAb) 2.4 56.9
Dry bulb(°F) y 41 90 Infiltration:
Daily range(°F) - 15 ( L ) Method Simplified
Wet bulb(°F) �' - 77 Construction quality Average
Wind speed(mph) ! 15.0 7.5 Fireplaces 0
II
Construction descriptions I; Or Area Uaralue Insul R Htg HTM Loss Clg HTM Gain
ft' Btuh/ft"F fULT/Btuh Btdvw Btuh Bhdff Btuh
Walls
1613-19ad:Knee wall,asphalt shingles roof mat,r-19 kw ins,1/2"gypsum ne 20 0.049 19.0 1.42 28 2.59 152
board int fnsh se 20 0.049 19.0 1.42 28 2.59 52
sw 20 0.049 19.0 1.42 28 2.59 52
nw 20 0.049 19.0 1.42 28 2.59 52
all 80 0.049 19.0 1.42 114 2.59 207
Blk wall,stucco ext,r-4 ext bd ins,8"thk,1/2"gypsum board int fnsh ne 416 0.201 4.1 5.83 2427 4.98 2075
r e 37 0.201 4.1 5.83 216 4.98 1184
se 379 0.201 4.1 5.83 2210 4.98 1889
sw 406 0.201 4.1 5.83 2366 4.98 2022
r
nw 179 0.201 4.1 5.83 1045 4.98 :893
all 1418 0.201 4.1 5.83 8264 4.98 7065
I
Partitions
12C-0sw..Frm wall,1/2"gyp.bd ext,r-13 cavi ins,1/2"gypsum board int 281 0.091 13.0 2.64 742 1.31 ;369
fnsh,TA"wood frm,16"o.c.stud
I �
Windows li .
2A 2ov:2 glazing,cir lowe outr,air gas,vnl ftm mat,cir innr,1/4"gap,1/8" ne 10 0.280 0 8.12 79 16.4 1160
thk;NFRC rated(SHGC=0.22);50%drapes,medium;1.33 ft overhang
(3.17 ft window ht,0.88 ft sep.);6.67 ft head ht
2A 2ov:2 glazing,cir lowe outr,air gas,vnl frm mat,cir innr,1/4"gap,1/8" ne 16 0.280 0 8.12 131 16.4 265
thk;NFRC rated(SHGC=0.22);50%drapes,medium;1.33 ft overhang
(5.25 ft window ht,0.88 ft sep.);6.67 ft head ht sw 32 0.280 0 8.12 263 14.5 468
all 49 0.280 0 8.12 394 15.1 733
2A-26v:2 glazing,cir lowe outr,air gas,vnl f rm mat,clr innr,1/4,gap,1/8" a 13 0.280 0 8.12 102 7.60 95
thk;NFRC rated(SHGC=0.22);50%drapes,medium;12.1 ft overhang(5
ft window ht,0.29 ft sep.),6.67 ft head ht
4
10C-v:2 glazing,cir lowe outr,air gas,vnl frail mat,clr innr,1/4"gap,1/8" se 18 0.340 0 9.86 175 5.97 106
thk;NFRC rated(SHGC=0.22);50%drapes,medium;10.17 ft overhang
(6.67 ft window ht,0.58 ft sep.);6.67 ft head Fit
I
i
- wrightsoft- !' 2022-Apr-1816:58:15
Right SutelD Uriversal 2021 2l.O.O7 RSU24015 Page 1
A+CA ...ersbrie2508CRGF?Lot38BIIQWatersbrie2608CRGRrtp Calc=W8 Housefaces:NW
I
I'
b
2A-2ov:2 glazing,dr lowe outr,air gas,vnl,frm mat,dr innr,1/4"gap,1/8" se 13 0.280 0 B.12 102 7.60 ! 95
thk;NFRC rated(SHGC=0.22);50%drapes;'medium;7.17 ft overhang(5
ft window ht,0.29 ft sep.);6.67 ft head ht I,
2A 2ov:2 glazing,dr lowe outr,air gas,vnll1frm mat,dr innr,1/4"gap,1/8" se 30 0.280 0 8.12 244 7.60 228
thk;NFRC rated(SHGC=0.22);50%drapes,medium; 10.17 ft overhang
(5 ft window ht,0.33 A sep.);6.67 ft head ht
II I
2A-2ov:2 glazing,cir lowe outr,air gas,vnl',frm mat,dr innr,1/4"gap,1/8" se 49 0.280 0 8.12 394 15.0 726
/r.thk;NFRC rated(SHGC=0.22);50 drapes;medium;1.33 ft overhang
(5.25 ft window ht,1.17 ft sep.);6.67 ft head ht
10C-v.2 glazing,dr lowe outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" sw 18 0.340 0 9.86 175 5.97 106
thk;NFRC rated(SHGC=0.22);50%drapes;)medium;23.67 ft overhang
(6.67 ft window ht,0.58 ft sep.);6.67 ft head ht
I
i
2A-2ov:2 glazing,dr lowe outr,air gas,vnl fnn mat,cir innr,1/4"gap,1/8" nw 32 0.280 0 8.12 263 15.3 495
thk;NFRC rated(SHGC=0.20);50%drapes,medium;7 ft overhang(5.25
ft window ht,0.48 ft sep.);6.67 ft head ht
2A-2ov:2 glazing,cir low-e outr,air gas,vnlifrm mat,cir innr,1/4"gap,1/8" nw 39 0.280 0 8.12 313 15.3 589
thk;NFRC rated(SHGC=0.20);50%drapes;]medium;1.33 ft overhang
(6.25 ft window ht,2.85 ft sep.);6.67 ft heatl;�ht
2B 2fv:2 glazing,cir lowe outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" nw 8 0.290 0 8.41 63 18.9 1 141
thk;NFRC rated(SHGC=0.21);11.83 ft ovefiang(1.5 ft window ht,0 ft
sep.);6.67 ft head ht I
I'
2B-2fv:2 glazing,dr lowe outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" nw 13 0.290 0 8.41 112 16.0 1213
thk;NFRC rated(SHGC=0.21);50%drapes,j medium;11.83 ft overhang
(6.67 ft window ht,2.13 ft sep.);6.67 ft head;ht
2B-2fv:2 glazing,cir lowe outr,air gas,vnl fnn mat,cir innr,1/4"gap,1/8" nw 6 0.340 0 9.86 59 17.3 '104
thk;NFRC.rated(SHGC=0.22);50%drapes,medium;1.33 ft overhang(1
ft window ht,1.17 ft sep.);6.67 ft head ht
Doors j!
11JO:Door,mtl fbrgl type ne 16 0.600 6.3 17.4 272 17.6 275
nw 20 0.600 6.3 17.4 348 17.6 352
i, all 36 0.600 6.3 17.4 620 17.6 626
11DO:Door,wd sctype i, n 18 0.390 0 11.3 201 11.4 203
I
Ceilings
16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 veil ins,1/2" 2526 0.032 30.0 0.93 2344 1.69 4268
gypsum board int fish
I
Floors
22A-tpl:Bg floor,light dry soil,on grade depth 243 0.989 0 28.7 6967 0 1 0
i'
i1
�I
,
II
I
I
! I
i
I I
t -Fp- wrightsoft- III 2022-Apr-1816:50:15
Right Sute®Uriversal2021 21.0.07 RSU24015 Paget
,+CA ...erstone2508CRGR1Lot38BIIQWatersbre2508CRGF.xW Calc=W8 Hotsefaces:NW
I
I
Pro ect Summary Job: Lot 38 Block 2Wateistone...
- wrightsoft® Date: NOVEMBER 3,2010
Entire House By. DCS
Del-Air'Heating &Air Conditioning
531 Codism Way,Sarford,FL 32771 Phore:407-333-2665 Fax 407-333-3853 Web:vmwdelair com License:CAC05147
Project • •
III
For. Adams Homes
8521 Waterstone Boulevard,Fort Pierce,FL 34951
� I
Notes: j HARVSD 6/13/13,RVSD 8-21-15 JA,L.S. 2-4-21 VWK,
IiRvsd Window numbers 4.15.2022 RH
Design Information
I, Weather: St Lucie Co Infl,FL,US
Winter Design Conditions Summer Design Conditions
Outside db 41 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 29 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 57 grAb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 25506 Btuh Structure 22727 Btuh
Ducts 5546 Btuh Ducts 7565 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cim) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 31052 Btuh Use manufacturers data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 30293 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3291 Btuh
Duds 1884 Btuh
i Central vent(0 cfm) 0 Btuh
,eat' Cooling (none)
Area(fF) 2523 2523 Equipment latent load 5175 Btuh
Volume(f?) 22232 22232
Airchangesmour I, 0.32 0.16 Equipment Total Load(Sen+Lat) 35467 Btuh j
Equiv AVF(cfm) j; 119 59 Req.total capacity at 0.75 SHR 3.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model 25HBC542AP03; Cond 25HBC542AP03
AHRI ref 204837283 ;' Coil FB4CNP048L00
AHRI ref 204837283
Efficiency i 8.5 HSPF Efficiency 12.5 EER,15 SEER
Heating Input Sensible cooling 31500 Btuh
Heating output 42000 Btuh @47°F Latent cooling 10500 Btuh
Temperature rise 27 OF Total cooling 42000 Btuh
Actual airflow 1400 cfm Actual airflow 1400 cfm
,i Airflowfactor 0.045 cfrn/Btuh Airflowfactor 0.046 cfm/Btuh
Static pressure 0.40 in H2O Static pressure 0.40 in H2O
Space thermostat Load sensible heat ratio 0.85
Capacity balance point=33°F
Backup:
Input=8 kW, Output=28165 Bt,1uh,100 AFUE
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
i'
-Fk- wrightsoft® 2022-Apr-1816:58:15
^�- wwM.-n,v-e.-, Rg1FSute®Uriversal2021 21.0.07 RSU24015 Page 1
ACCA ...ersbre2508CRGR1Lot38BIIQWaterstore2508CRGRnp Calc=MAB Horsefaces:NW
� I
I
wrightsofV Right-J®Worksheet Job: Lot38 Block 2 Waterston 25...
Entire House Date: NOVEMBER 3,2010
By. DCS
Del-Air Heating $Air Conditioning
1I
531 Codisco Way,Sarford,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:wwwdelair.com License:CAC05147
1 Room name Entire House MASTER BDRM 1
2 O posed wall 242.9 ft 41.0 ft
3 Room height 8.8 ft 8.0 ft heaV000l
4 Room dimensions 14.0 x 18.0 ft
5 Room area I 2525.9 f12 252.0 T
Ty Construction U-value, :1 Or HTM Area (fF) Load Area (f2) Load
number (BtuhlftLT) (Btu or perimeter (ft) (Bhih) or perimeter (ft) (Btuh)
j Heat Cod Gross NIPS Heat Cool Gross NIPS Heat Cool
6 W 16B-19ad 0.049 ne 1.42 2.59 26 26 28 52 0 0 0 0
Blk wall,stucco ext 0261 ne 5.83 4.98 458 416 2427 2075 144 144 839 718
2A 2ov 0280 ne 8.12 16.38 10 0 79 160 0 0 0 0
2A 2ov 028D ne 8.12 16.38 16 0 131 265 0 0 0 0
11 11J0 0.600 ne 17.40 17.58 16 16 272 275 0 0 0 0
Slk urall,stucco ext OA,1 a 5.83 4.98 49 37 ,216 184 0 0 "" 0 {0
L- G•2A 2ov-,. 0280 a 8.12 7.60 13 13 -,101 95 0 _ 0 0 0
W 1613-19ad 0.049 se 1.42 2.59 20 20 28 52 0 0 0 0
Blk wal(slu000 ext 0201 se .5.83, '4.98 488 379 2210 1889 112 ;86 464 '397
10C-v 0.340 se 9 86 5.97 18 18 175 106 :0 0 0 0
2A 2ov 0280 se 8.12 7.60 13 '13 101 95 0 0 -0 - 0
2A-2ov 0280 se 8.12 7.60 30 30 '244 228 0 0 0 .0
2A-2ov 0280 se 8.12 14.96 49 9 .394 726 32 6 263 484
W 1613-19ad 0.649 sw 1.42 2.59 20 20 28 52 0 0 0 0
Blk wall;stuooc ext' 0261 sw 5.83. 4.98 466 406 MN 2022 72 54. = 316• 270
-G 10C-v 0.340 sw 9.86 5.97 18 '18 `175 106, 18- 18 175 106
`-G. 2Pr2ov 0280 sw' - -.'8.12 14.46 32 8 263 ..468. 0 0 0 ;0
W 1613-19ad 0.049 nw _ 1.42 2.59 20 20 28 52 0 0 0 IO
Blk wall,stu000 ext 0201 nw' '5.83 4.98 297 179- 1045 893: 0 0 0 '•.0
2A2ov- 0280 nw 8.12 - 1529 -32 0 ,.263 495 0 0 0 ;• 0
2A 2ov- 0280 nw -'8.12 _. 1529 .39 0 313 589 0 0 0 -10
2B-2fv_ = 0290 nw 841 - 18.85 '8 0 -63 14.1 6 0 0 10
213-2fv 0290 rw 8A1 15.99 13 0 112 213 0 0 0 - 10
28-2ry 0.340 nw 9.86 17.31 - 6 0 .59 164 0 0 0 0
11JO, 0.6W nw 17.40 17.58 20 20 348 352 0 0 0 ,1 0
P 12C-Osw 0.091 - 2.64 1.31 299 281 742 369 0 0 0 0
L-D, 11DO 0.390 n 11.31 11.43 18 18 201 . 203 0 0 0 0
C 16B�Oad 0.032 - 0.93 1.69 2526 2526 2344, 4268 252 252 234 426
F 22A tpl 0.6189 - 28.68 0.00 2526 243 6967 0 252 41 1176 0
6 ;c)AED excursion ' 444 - 121
Envelope losslgain 21727 16974 3468 2522
12 a) Infiltration I; 3779 1003 678 180
b) Room ventilation I• 0 0 0 10
13 Internal gains Occupantsl@ 230 5 1150 1 230
Applianoes/other 3600 300
Subtotal(lines 6 to 13) 25506 22727 4145 3232
Lessextemal load 0 0 0 0
Less transfer ,I, 0 0 0 0
Redisfibution ;. 0 0 0 10
14 Subtotal Y 25506 22727 4145 3232
15 Duct loads 220/6 33% 5546 7565 22% 33%1 901 10,
Total room load 31052 30293 5047 4308
Air required(din) 1400 1400 228 199
i
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-rr}- wrightsolFt- I I� 2022-Apr-1816:58:15
RighESute®Uriversal 2021 21.0.07 RSU24015 Page 1
...erthre2508CRGRXLot38Blk2WaterstDrg2508CRGRnp Calc=W8 Hou>efaces:NW
i
- 1-wrightsoft Riglit-,l®Worksheet
Job: Lot 38 Block 2 Wate'tone 25...
Entire House Date: NOVEMBER 3,2010 �
By. Dcs
Del-Air Heating $Air Conditioning
r !
531 Codisco Way,Sanford,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:ww&delair.com License:CAC05147
1 Room name M WIC M WIC II
2 Exposed wall 8.5 It 0 It
3 Room height 8.0 ft heatf000l 8.0 It heaVcod
4 Room dimensions 7.0 x 8.5 ft 7.0 x 8.5 ft
5 Room area j 59.5 it= 59.5 ft'
Ty Construction U-value Or HTM Area (fF) Load Area (ft=) Load
number (Btutvjr-t-) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 'W " 1613-19ad 0.049 ne 1.42 2.59 0 _ 0 0 0 0 _6 0 j 0
BIk wall,stuom ext 0201 ne 5.83 4.98 68 68 396 339 0 0 0 0
2A-2ov, 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
2A 2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
11 11,10 0.600 ne 17.40 17.58 0 0 0 0 0 0 0 0
yJ " B(k wall,shucoo ext 0201 a 5.83 4.98 0 0 0 0 0 0 0 0
�G 2A 2ov.: 02.80 e _ 8.12 7-W 0 0 0 0 -0 0 . _ 0 0
W 168-19ad 0.049 se 1.42 2.59 0 0 0 0 0 0 0 0
BIk wal,womext 0201 se 5.83 4.98 0 0 0 0 . 0 0 6 0
910C-v 0 340 se 9.86 5.97 0 0 0 0 0 0 0 0
2A 2ov 0280 se 8.12 7.60 0 0 ; 0 0 0 0 0 i 0
2A2ov 0280 se 8.12. 7.60 ''0 0 0 0 0 0 0 "� 0
.2A-2ov 0280 se 8.12 _ 14.96 0 0 .0 0 0 0 0 0
W 1613-19ad 0.049 sw 1.42 2.59 0 0 0 0 0 0 0 0
Pk wall,stucco ext- 0201 sw, 5.83 4.98 0 0 0 0 0 0 0 10,
--G 10C-v 0.* sw 9.86 -5.97 0 0 0 0 6 6 0 0
�--G 2A 2ov. 0280 sw 8.12 14.46 0 0 0 0 ` 0 0 0. 0
W 16B-19ad 0.049 nw 1.42 2.59 0 0 0 0 0 0 0 10
Blk vuall,stucco ext 0201 nvv 5113 4.98 0 0 0 0 0 6 0' ;0
2A 2ov 0280 rw 8.12 1529 0 0 0 0 0 0 0 0
2A 2ov 0280 nw 8.12 1529 0 0 0 0 0 0 0 .10
2B-2fv 0290 nw 8A1 .' 18.85 0 0 '.0 0- 0 0 " 6 0
213-21v 0290 nw ' 841' 15.99 EO 0 0 ..0 -0 0 0 0
213-21`v 0340 nw. 9.86 1731 0 0 0 0 0 0 0 0
11JO 0.600 nw 17.40 17.58 0 0 0 0 0 0 0 0
PI - 12C-0sw 0.061 - 2.64 1.31 0 0 0 0 0 0 0 0
D 11DO 0.390 n 11.31 11.43 0 0 0 0 0 0 0 0
•C 16B30ad 0.032 - 0.93" 1.69 60 60 55 101 . 60 60 55 101
F 22A-fpl 0.989 - 28.68 0.00 60 9 244 0 _ 60 0 0 0
I
-
6 c)AED excursion �' -17
Envelope loss(gain 695 422 55 97
12 a) Infiltration 141 37 0 IO
b) Room ventilation 0 0 0 0
13 ''Internal gains: Occupants @ 230 0 0 0 I0
Applianoeslofher 0 0
Subtotal Qines 6 to 13) 836 460 55 97
Less exlemal load 0 0 0 10
�Lesstransfer 0 0 0 10
Redistribution 0 0 0 0
14 Subtotal 836 460 55 97
15 ',Dudloads 22% 33% 182 153 221/6 33% 12 32
Total room load 1018 613 67 129
Air required(o5n) 46 28 1 3 6
I
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
- wrightsoTt- 2022-Apr-1816:58115
Right-Su"Uriversal202121.0.07RSU24016 Paget
ersbne2508CRGR1Lot38811QWaterstone2508CRGRnp CaIc=MJB Hoisefaces:NW
ii
Y ,
+wrightsoft' Right-J@ Worksheet Job: tot 38 Block2 Waters tone 25...
Date: NOVEMBER 3,2010
Entire House
,; �i By. DCS
Del-Air Heating &Air Conditioning
531 Codisco Way,Sanford,FL 32771 Phone:407-333-2i665 Fax 407-333-3853 Web:wwwdelair.00m License:CAC05147
1 Room name MASTER BATH M W/C
2 E)posed wall 10.5 ft 0 It
3 Room height 8.0 ft heat/cool 8.0 It heaticool !
4 Room dimensions I 1.0 x 126.0 It 3.5 x 6.0 It
5 Room area 126.0 ft' 21.0 fP
Ty Construction U-value, I Or HTM Area (fF) Load Area (fF) Load
number (Btuh/It;°9 (BtuhflF) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cod Gross NIP/S Heat Cool
i
6 W 166-19ad 0.049 ne 1.42 2.69 0 0 0 0 0 0 0 0
Blk wall,stucco ext 0201 ne 5.83 4.98 84 74 433 370 0 0 0 0
2A 2ov 0280 ne 8.12 16.38 10 0 79 160 0 0 0 10
2A 2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 10
11 11,10 0.600 ne 17.40 17.58 0 0 0 0 0 0 0 10
1V�fJJ � Blkvvall,stuccq ext 020,1 a 5.83 4.98 0 0 0 6 .0 0' o 0
G 2A-2ov 0280 a 8.12 .7.60 0 0 0 0 0 0 ' 0 0
W 16B-19ad 0.049 se 1.42 2.59 0 0 0 0 0 0 0 '0
Blk wall,stuoco e)d 0201 se 6.'M .: '
10C-v 040 se 9.86 5.97 0 ' - 0 ' 0:, 0 0 . 0 0 `, 'i 0
2A 2ov 0280 se 8.12 7.60 0 0 ",0 0 0 0 _ 0 '0
2A-2ov 0280 se- 8.12 7.60 0 0 0 0 0 0 0 i 0
2A 2ou 0280 se _ 8.17 14.96 0 0 0 0 0 0 0 0
,W 1613-19ad 0.049 sw 1.42 _ 2.59 0 0 0 0 0 0 0 0
� Bik wall,stucco e)d 0201 sw 5.83, 4.98 0 0 +' . !,0 6 0 0 0 !0
10G-v 0 340 sw 9.8fi 5.97 0 0 0 0' 0 0 0 ;0
2A-2ov." 0280 sw 8.12 14A6 •0 0 0 •0 0 0 0 _ 10
W 16B-19ad 0.049 nw 1.42 2.59 0 0 0 0 0 0 0 1,0
Blk wall,sWmo e)d 0201 nw 5.63 4.98 0 0 0 0 0 0 0 >,0
2A 2ov 0280 nw 8.12 1529 ", 0 0 0 0 0 0 0 0
2A-2ov 0290 nw 8.12 1529 0 0 0 ' 0 0 0 0 0
2B-2fv 0290 nw 8AI 18.85 0 0 0 -0," 0 0 0 1,0
213-2fv _ 02W nw 841 15.99 0 0 0 0 0 0 0 10
213-2fv 0-340 nw 9.86 17.31, 0 0 0 0 0 0 0. 0
11JD 0.8O, nw 17.40 ` 17.58 0 0 0 0 0 0 0 0
P 12C-0sw 0.69' 2.64 1.31 0 0 0 0 0 0 0 0
11DO 0.390 n 11.31 11.43 0 0 0 0 0 0 0 0
C 1613-Wad 0.032 - .0.93 1.69 126 126 117 -213 21 21 19 35
F 22A-tpl 0.989 - 28.68 0.00 126 11 301 0 21 0 0 0
fh
6 c)AED excursion y -28 1
Envelope Iosslgain 930 715 19 34
12 a) Infiltration 174 46 0 0
b) Room ventilation 0 0 0 10
13 ,i Internal gains Oaupan '�@ 230 0 0 0 IO
Appliances/other 0 0
Subtotal Qines 6 to 13) I 1104 761 19 34
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 ,Subtotal 1104 761 19 34
15 ,Dudloads 22% 33% 240 253 22% 33% 4 11
Total room load 1344 1014 24 46
Air required(dm) 61 47 1 12
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-OrI- wr➢gtitsoTt- l :1 2022-Apr-1816:415
RigttSuteoUriversal202121.0.07RSU24015 Page3
erstore2508CRGFMot38BIIQWaterstone26'08CRGRnp Calc=MJ8 Hoisefaces:NW
wrightsoft° Ri fit-.1®Worksheet Job: Lot 38 Block 2 Waterston 25...
En ire House Date: NOVEMBER 3,2010
By. DCS
Del-Air Heating &Air Conditioning
531 Codisco Way,Sardord,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:wwadelair.com License:CAC05147
1 Room name LMNG RM FAMLY RMFOYER
2 Dposed wall 31.5 ft 25.0 ft
3 Room height 8.0 ft heat/cool 10.0 ft heaUcool
4 Room dimensions 14.0 x 13.5 ft 1.0 x 569.0 ft
5 Room area j 189.0 iP 569.0 T
Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load
number (BluhfiF--°F) (BtuhfiF) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat I Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 16B-19ad 0.049 ne 1.42 2.59 0 0 0 6 20 20 28 !52
Blk wall,stucco ext 0201 ne 5.83 4.98 108 92 535 458 0 0 0 0
2A-2ov 0,280 ne 8.12 16.38 0 0 0 0 0 0 0 0
2A-2ov 0280 ne 8.12 16.38 16 0 131 265 0 0 0 0
11 111,10 0:600 ne 17.40 17.58 0 0 0 0 0 0 0 0
yJ Blk wall,sfu000 eM 0261 a 5.63 -4.98 0 0 0 0 0 0 0 0
L--.f 2A 2ov 0280 a 8.12 7.60 0 0 0 0 0 0 .- 0 0
W 1613-19ad 0.049 se 1.42 2.59 0 0 0 0 20 20 28 :52
Blk wall,stuom ad 0201 se 5.83 4.98 0 0 0 0 180 " 132 771 659
10C-v 0:340 se 936 5.97 0 0 0 - 0 18 18 175 106
2A 2ov 0260 se 8.12 7.60 6 0 0 0 0 0 0 0
2A-2ov 0280 se 8.12 7.60 0 0 0 0 30 30 244 228
2A-2ov 0280 se "8.12 14.96 0 0 0 0 0 0 0 . 0
W 1613-19ad 0.649 sw 1.42 2.59 0 0 0 0 20 20 28 .152
V�J Bik well,stucco ext 0261 sw 6.83 4.98 32 32 187 159 0 0 0 0
I-G IOC-v 0.* sx 9.86 5.97 0 0 0 0 .0 0 0 0
�-G 2A-2ov. 0280 sw 5.12 14.46 0 0 0 0 0 0 0 0
W 16B-19ad 0.049 nw 1.42 2.59 0 0 0 0 20 20 28 .52
Blkwall,stucooext 0201 nw 5.83 4.98 112 80 464 397 70 29 170 i45
2A 2ov 0280 nw 8.12 - 1529 32 0 263 495 0 0 0 0
2A-2ov 0280 nw 8.12 1529 0 0 0 0 0 0 0 i 0
2B-2fv 0290 nw 8.41 18.85 - 0 0 0 0 8 0 63 141
2B-2fv 0290 nw 8.41 15.99 0 0 0 0 13 0 112 213
28-2fv 0 940 nw 9.86 17.31 0 0 0 0 0 0 0 i 0
11JO 0.600 nw 17.40 17.58 0 0 0 0 20 20 348 352
P 12C-0sw 0.091 - 2.64 1.31 0 0 0 0 0 0 0 0
" 1160 0.390 n 11.31 11.43 0 0 0 0 0 0 0 0
C 16B30ad 0.W2 - 0.93 1.69 189 189 175 319 569 569 528 961
F 22A tpl 0.969 - 28.68 0.00 189 32 903 0 569 25 717 0
i I
i
I
I�
f, I
f
f
i
6 ., c)AEDexcursion 122 -102
Envelope loss(gain !i 2659 2216 3242 2911
12 a) Infiltration 521 138 682 181
b) Room ventilation 0 0 0 10
13 Internal gains: Occupants @ 230 1 230 2 460
Applianoes/other 0 600
Subtotal Qines 6 to 13) 1'I 3180 2584 3924 4152
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 3180 2584 3924 4152
15 Duct loads 22% 33% 691 860 22% 33% 853 1382
Total room load 3871 3444 4777 5535
Air required(dm) 175 159 215 256
I
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
_ -F}a- wrlglft ft- I,I 2022-Apr-1816:58:15
�.`A 9-y RigII Sutee Universal 2021 21.0.07 RSU24015 Page 4
ersbrie2508CRGR\Lot38BIIQWaterstorie2508CRGRnp Calc=MJ8 Horse%ces:NW
4
- -wrightsoft� Right-.1®Worksheet Job: L.ot38 Block 2 Waterston 25...
Entire House Date: NOVEMBER 3,2010 �
Del-Air Heating &Air Conditioning By. Dcs
531 Codisco Way,Sanford,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:wwKdelair.mm License:CAC05147
1 Room name DINING RM BRIFST
2 Erposedvdl 18.0 ft 8.9 ft
3 Room height 10.0 ft heat/cool 10.0 It heat/000l
4 Room dimensions 13.5 x 14.5 it 1.0 x 91.6 ft
5 Room area 195.8 IF 91.6 ft2
Ty Construction U-value Or HTM Area (fF) Load Area (ft') Load
number (Btuhff (Btuht>f`) or perimeter (ft) (B1uh) or perimeter (ft) (Btuh)
Heat Cod Gross NIPS Heat Cod Gross N/P/S Heat Cod
6 W 161!3;19ad 0.049 ne 1.42 -.Z69- 0 0 0 6 0 0 0 i 0
Blk wall,stuom ext 0201 ne 5.83 4.98 10 10 58 50 0 0 0 0
2A 2ov 0:280 ne 8.12 16.38 0 0 0 0 0 0 0 0
2A-2ov ONO ne 8.12 16.38 0 0 0 0 0 0 0 0
11 11,10 0.'600 ne 17AO 17.58 0 0 0 0 0 0 0 0
y1 Blk wall,suom LA 0261 a 5.83 4.98 0 0 .0 0 49 '37 216 184
�G 2A-2ov_ 0280 a 8.12 7.60 0 0 0 0 : 13 _ 13 101 95
W 16B-19ad 0.049 se 1.42 2.59 0 0 0 0 0_ 0 _ 0 i 0
Blk wall,stu0oo-eid 0201 se 5.83 4.98 0 0 `. 0 0 40 28 160 137
10C-v 0340 se 9.86 " 5.97 0 0 0 0 0 .0 0 ! 0'
2A 2ov 0280 se 8.12 7.60 0 0 0 0 13 13 101 95
2A 2ov 0280 se 8.12 7.60 0 0 0 0 0 0 0 0
2A 2ov 0280 se 8.12 14.96 0 0 0 0 0 0 0 j_0
W 1613-19ad 0.049 sw 1.42 2.59 0 0 0 0 0 0 0 0
Blk wall,shroo0 ext 0201 sw 5.83 4.98 0 0 0 0 0 0 0 0
10C-v 0:340 sw 9.86 5.97 0 0 0 0 `, 0 0 0 0
2A-2ov 0280 sw 8.12 14.46 0 0 0 - 0 0 :.0 0 0
W 16B-19ad obo nw 1.42 2.59 0 0 0 0 0 0 0 0
Blk wolf,slu00o ext 0201 nw 5.83 4.98 115 70 411 351 0 0 0 ; ,0
2A 2ov 0280 nw 8.12 1529 0 0 0 0 0 0 0 0
2A 2ov 0280 nw _ 8.12 1529 39 . 0 313 589 0 0 0 i 0
26-211 0290 nw 8.41 18.85 0 0 0 0 0 0 0 f 0
213-21`v 0290 nw 8.41 15.99 0 0 0 0 0 0 0 0
26-21`v 0:840 nw -9.86 17.31 6 0 59 104 0 0 0 0
11.10. 0.' nw 17.40 17.58 0 0 0 0 0 0 0 0
PI 12C-0sw 0.091 - 2.64 1.31 55 55 145 72 0 0 0 0
" 11DO 0:390 n 11.3.1 11.43 0 0 0 0 0 0 0 0
C 16B30ad 0.032 - 0.93 1.69 166 .196 182 331 92 92 85 155
F 22A-tpl 0 i989 - 28.68 0.00 196 18 516 0 92 9 256 0
I'
i
III„'I I
I� I
6 c)AED excursion 297 26
Envelope losstgain 1684 1793 920 641
12 a) Infiltration 258 69 185 49
b) Room ventilation I' . 0 01 0 0
13 Internal gains Occupant's @ 230 1 230 0 0
Applianoes/other 0 0
Subtotal(lines6to13) 1942 2092 1105 690
Less extemal load 0 0 0 10
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 ' Subtotal 1942 2092 1105 690
15 Dud loads 22% 33% 422 696 22% 33% 240 230
i
Total room load 2365 2788 1345 920
Air required(dm) 107 129 61 .420
i
Calculations approved DyACCAto meet all requirements of Manual J 8th Ed.
A- wrlgtitsoTt^ li 'I 2022-Apr-18 16:5 8:15
RigttSiite®Uriversal202l2l.O.O7RSU24015 Page
erstone2508CRGR1Lot38BIIQWaterstorie2508CRGP-np Calc=MJ8 Horsefaces:NW
i
t
wri htsoft° Ri ht-M Worksheet Job: Lot 38 Block 2 Waterston 25...
9 Enure House Date: NOVEMBER 3,2010
By. DCS
Del-Air Heating &Air Conditioning
531 Codisco Way,Sanford,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:www.delair.com License:CAC05147
1 Room name WTCHEN UTILfrY
2 Exposed wall �i 0 ft 10.5 It i
3 Room height 10.0 It heaV000l 8.0 ft heat/cool
4 Room dimensions P 13.0 x 12.0 ft 7.5 x 16.0 It
5 Room area 156.0 ft2 120.0 fF
Ty Construction U-value Or HTM Area (fF) Load Area (i2) Load
number (Btuhd-F) (BtuhA?) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool f
6 1N 168719ad 0.049 ne 1 1.42 159 ,0 0 ;0 0 `0 _0 6 0
WV Blk Hell,stu000 ext 0201 ne 5.83 4.98 0 0 0 0 0 0 0 0
2A 2ov 0.280 ne 8.12 16.38 0 0 0 0 0 0 0 ! 0
2A-20v 0.280 ne 8.12 16.38 0 0 0 0 0 0 0 1 0
11 11,10 0.600 ne • 17.40 17.58 0 0 0 0 0 0 0 0
Blktnell,stucco ext.`. 02d1 a 5.83 4.98 0 0 0 0 0 '0 0 0
2A=2ov 0.280 a 8.12 `,7.60 0 0 0 0 .` 0 __0 :: 0 0
W 1613-19ad 0.049 se 1.42 2.59 0 0 0 0 0 0 0 0
Blk wall,sWcbo ext 0201 s8 5.83 4.98_ 0 0
U 0 0 0 0 0
10C-v 0.340 se 9.86 - 5.97 0 0 0 0, 0 0 0 0
2A 2ov . 0280 se 8.12 7.60 0. - 0- •6 0 0 0 0 0
2A 2ov 0280 se 8.12 7.60 0 0 0 0 0 0° 0 0
2A-2ov 0280 se 8.12 14.96 0 0 0 91. 0 0 0. 0
W 1613-19ad . 0.049 sw 1.42 2.59 0 0 0 0 0 0 0 0
Blk wall,stucco ext. 0201 sw 5.83 "4.98 0' 0 0 0 - 0 0 0 L 0
--G 10C-v 0.3 0 sw 9:86 5.97: 0 0 0 0. 0 0 0 0
r--G 2A 2ov 0280 snr 8.12 14.46 0 - 0 0 0..` 0 0 0 0
W 16&19ad 0.049 nw 1.42 2.59 0 0 0 0 0 0 0 1 0
Blk urall,slu000 exi., 0201 rrw, 5:83 • 4.98 0 0 0 0 0 0 0 r•:;,0
2A 2ov 0280 nw 8.12 „, 1529 - �0 0 -0 ' 0- . 0t 0
2A 2ov 0280 nw 8.12 1529 0 0 -0 0 0 0, 0 0
28 2fv 0290 nw. 8.41 -;;18.85 0 0 `0 0 0 0.. 0 0
2B-2fv 0290 nw' 841 15.99 0 0 0 0 - 0 0. 0 4 0.
2 -2fv 0.,b nw 9.86 17 31 0 0 0 0 0 0 0 d 0
'_ 11J0 0.' nw 17.40 17.58 '0 0 0 0 : 0 0 0 1111I 0
P 12C-0sw ob 1 - 2.64 1.31 0 0 0 0 84 66 175 87
L-D 11DO 0.390 n 11.31 11.43 0 0 0 0 18 18 201 203
C 16S- Mad 0.032 - 0.93 1.69 156 156 145 264 120 120 111 "" 203
'F- 22A tpl 0.989 - 28.68 0.00 156 0 0 0 120 11- 301 0
6 c)AED excursion -52 39
I Envelope loss(gain III 145 211 788 454
12 a) Infiltration �� 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 10
Applianoesuother 1200 600
Subtotal(lines 6 to 13) l 145 1411 788 1054
Less external load 0 0 0 0
j Less transfer 1, 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 145 1411 788 1054
15 Duct i; . 22% 33% 31 470 22% 33% 171 351
c
Total room load 176 1881 960 1404
Air required(dm) 8 87 43 165
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-F�t wrigFftsoTt^ ;'i I 2022-Apr-1816:58:15
AC�GA W '••^•_••a Right SuiteO Uriversal 2021 21.0.07 RSU24015 Page 6
erstone2508CRGR\Lot38BIIQWaterstorie2508CRGRnp CaIc=MJB Horselaces:NW
II
n
II
� I
-�-wrightsoft Riga W@ Worksheet fob: Lot38 Block 2 Waterstone 25...
Entire House Date: NOVEMBER 3,2010
By. DCS
Del-Air Heating &Air Conditioning
531 Codisco Way,Sanford,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:ww&delair.com License:CAC05147
1 Room name BATH 2 BDRM2
2 E)posed wall 5.5 ft 30.5 ft
3 Room height 8.0 ft heaticool 8.0 ft heat/cool
.4 Room dimensions 5.5 x 13.0 ft 11.5 x 16.0 ft
5 Room area 71.5 fP 184.0 W
Ty Construclion U-value Or HTM Area (W) Load Area (ftz) Load
number (Bwn-I (Btu hAF) or perimeter (ft) (Btrrh) or perimeter (ft) (Btuh)
j Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cod '
6 W- I6&19ad'` _ 0.049 ne 1.42 2.59 0 0 0 - 0 . 0 0 0 0
Blk mall,strr000 ext 0201 ne 5.83 4.98 0 0 0 0 0 0 0 0
2A-2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
2A-2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
11 11JO 0.600 ne 17.40 17.58 0 0 0 0 0 0 0 0
yJ Blk,MI,stucooext 0261 a 5.83 4.98 0 0 0 0 0 0 0 j 0
t G 2A-2ov ,. 0280 a 8.12 7.60 0 0 0 0 0 0 0 0
W 1613•19ad 0:049 se 1.42 2.59 0 0 0 0 0 0 0 0
Blkvdi,stuood.6d 0201 se 5.83 4.98 6 0 0 0 0 0 0 0
F-G10C-v 0;340 se '926 5.97 0 0 0 0 0 -0 0 10
2A 2ov 0280 se 8.12 7.60 0 0 0 0 0 0 ' 0 0
2A-2ov 0280 se 8.12 7.60 0 0 0 0 0 0 0 0
2A 2ov 0280 se 8.12 14.96 0 0 0 0 -.. 0 0 0 0
W 1613-19ad 0.0.49 sw 1.42 2.59 0 0 0 0 0 0 0 0
V)1. BIk utell,stu000 ext 0201 sw 5.83 4.98 0 0 0 0 128 112 652 557
I�-GG 10C-v 0 340 sw 9.86 5.97 ;0 0 0 0 0 0 0 0
2A-2ov 0280 sw, 8.12 14.46 0 0 .-0 _ 0 16 4 131 234
W 1613-19ad 0 049 nw 1.42 2.59 0 0 0 0 0 0 0 0
BIk wall,shr000 ext 0201 nw 5.83 4.98 6 0 '0, 6 0 0 0 0
2A-2ov 0280 nw- 8.12 1529 0 - 0 0 0 0 0 0 0
2A-2ov 0280 rVW 8.12 1529 0 0 0 •0 0 0 0 0
26-2fv 0290 nw 8.41 18.85 0 0 .0 0 0 0 0 0
2B-2fv 0290 nw 8A1 15.99 0 0 0 0 0 0 0 0
213-2fv ONO nw 9.86 17.31 0 0 0 0 0 0 0 j.0
11,10 0.600 nw 17.46 . ' 17.58 0 0 .0 0 0 0 0 i3O
P 12C-0sw 0.001 - 2.64 1.31 44 44 116 58 116 116 306 152
L-D_ 11D0. 0:390 n 11.31 11.43 0 0 0 0 0 0 0 a 0
,C 16630ad 0.032 - 0.93 1.69 72 72 66 121 184 184 171 311
F 22A-tpl 0.989 28.68 0.00 72 6 158 0 184 31 875 ; 0
I
i
I ,I
^ r.
6 c)AED excursion -6 160
Envelope low/gain 340 172 2135 1314
12 a) Infiltration 0 0 265 70
b) Room ventilation 0 0 0 0
13 ' Internal gains Oavpants @ 230 0 0 0 I 0
Appliance;s/other 0 300
Subtotal(lines 6 to 13) I, 340 172 2399 1684
Less exlemalload 0 0 0 1 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 340 172 2399 1684
15 Duct loads 22% 33% 74 57 22% 33% 522 561
Total room load 414 229 2921 2245
Air required(dm) 19 11 132 104
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
- wrYgtits_o1Ft- 2022-Apr-1816:58:15
Rigti Sute®Unversal 2021 21.0.07 RSU24015 Page 7
erstone2508CRGR1Lot38Blk2Waterstorie2508CRGP-np Calc=MJ8 Horsefaces:NW
� I
I ,
y,
I
- -wrightsoft Right-J®Worksheet Job: L.ot38 Block 2 Waterston 25...
Entire House Date: NOVEMBER 3,2010
Del-Ai Heating &Air Conditioning By. DCs J
531 Codtsco Way,Sanford,FL 32771 Phore:407-333-2665 Fax 407-333-3853 Web:vwvwdelair.com License:CAC05147
1 Room name BDRM3 BDRM4
2 E)posed wall 14.0 it 25.5 it
3 ,Room height 8.0 ft heaVcool 8.0 it heaV000l
4 Room dimensions 11.5 x 14.0 ft 11.5 x 14.0 it
5 Room area ,� 161.0 fF 161.0 ft
Ty Construction U-value Or HTM Area M) Load Area (fF) Load
number (Btuhlft;°F) (BtuhfiF) or perimeter (ft) (Btuh) or perimeter (it) (Btuh)
Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cool
6 W 163-19ad- 0.049 ne 1.42 2.59 0 0 0 _ 0 0 0 6 10
BIk well,sluom ext 020.1 ne 5.83 4.98 0 0 0 0 0 0 0 0
2A-2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
2A-2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
11 11.10 0.600 ne 17.40 17.58 0 0 0 0 0 0 0 0
VN , BIk wall,stucco ext 0201 a 5.83• .4.98 0 0 -0 0 0 0 0 0
2A-Zov 0280 a 8.12 7.60 0 0 0 :0 0 wo 0 0
11V 16B 19ad 0.049 se 1.42 2.59 0 0 0 0 0 0 0 0
BIk`wall,stuodDext 0201 se 5.83, 4.98 0 0 - 0 .0 92 z76 - -442 378
10C-v 0.340, se 9.86 .; 5.97 0 0 p, .A ,0 0 0 0 0
2A-2ov 0280 se 8.12 7.60 0 0 0 0 0 .0 0 0
2A-2ov 0280 se 8.12 7.60 0 0 0 0 0 0 0 .0
2A-2ov 0280 se 8.12 14.96 D 0 1 0 - 0 16 3 131 242
W 1613-19ad. 0.049 sw 1.42 2.59 0 0 0 0 0 0 0 0
wa
ll,all,stucco ext 0201 sw 5.83 4.98 112 96 ,'558. 477,, 112 11'2 653 558
--G 10C-v• 0.340 sw 9.86 5.97 0 0 0 0 0 0 "0 0
�--G 2A-2ov 0280 Sw 8.12 14.46 16 4 131 '234 -0 0 0 0
W 16B-19ad 0.049 nw 1.42 259 0 0 0 0 0 0 0 0
W. BIk wall,stucco eM 0201 nw 5.83 4.98 0 0 ! 0 0 - 0 d 0 '0
2A-2ov 0280 nw 8.12 1529 0 0 0 0 0 0 0. 0
. 2A-2ov 02.80 nw -8.12, 1529 0 0 0 0 0 0 0 0
28-2fv 0290 nw 8.41 18,85 0 0 0 0 0 0 0 0
2B-2fv 0290 nw 8A1 15.99 0 0 '0 0 0 0 0 '0
03=21v 0.340 nw :9.86 17.31 0 0 0 0 0 ".0 0 0
11JO 0.600 nw :17.46 17.58 0 0 0 0 0 0 0 0
P 12C-0sw 0.091 - 2.64 1.31 0 0 0 0 0 0 0 0
�D 11DO 0.360 n 11.31 11.43 0 0 0 0 0 0 0 0
C. 16B-306d, 0.W2 0.93 1.69 161 161 149 272 161 161 149 272
F 22A-tpl 0.989 28.68, 0.00 161 14 402 0 161 26 731 0
ij
i
i
6 c)AEDwcursion pi , 70 84
Envelope loss/gatn it 1241 1053 2107 1534
12 ;a) Infiltration 231 61 422 112
b) Room ventilation ( : 0 0 0 0
13 ;jntemal gains Oocrpants @ 230 0 0 0 0
Appliances/other 300 300
;;Subtotal(lines 6 to 13) ;� 1472 1415 2529 1946
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1472 1415 2529 1946
15 ,Dudloads 22% 33% 320 471 229/6 33% 550 648
i
Total room load 1792 1886 3078 2594
Air required(dim) 81 87 139 120
Calculati Ins approved bVACCAto meet all requirements of Manual J 8th Ed.
-F}f wr gulft oTt 2022-Apr-1816:58±15
•� 11 .!w-! �-� RigaSumlvunversal202121.0.07RSU24015 Page"8
ACCK erstone2508CRGR\Lot38BII2Watsrstone2508CRGRnp Calc=MJ8 Housefaces:NW
+'wrightsoft° Right-M Worksheet Job: Lot38 Block 2 Waterstone 25...
Date: NOVEMBER 3,2010
Entire House BY Dcs
Del-Air Heating &Air Conditioning
531 Codisco Way,Sardord,FL 32771 Phone:407-333i,2665 Fax 407-333-3853 Web:wwwdelair.com License:CAC05147
1 Room name BATH 3'
2 Exposed wall 13Z ft
3 Room height 8.0 ft heaVood
4 Room dimensions 1.0 x 109.0 ft
5 Room area ii 109.0 T
Ty Construction U-value) Or HTM Area (1P) Load Area Load
number (BtuhAF-'F.) (BtiihltP) or perimeter (ft) (Btrrh) or perimeter
Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cool
6 W_ 1613-19ad 0:049 ne . 1.42 2.59 0 0 0 -- 0
Bilk%dl,shiom ext 02.01 ne 5.83 4.98 44 28 165 141
2A-2ov 0280 ne 8.12 16.38 0 0 0 0
2A-2ov 0286 ne 8.12 16.38 0 0 0 0
11 11,10 0AW ne 17.40 17.58 16 16 272 275 _
I81k wall,shi000 ext 0201 a 510 . 4.98 0 0 0 0
-G 2A 2ov 0280 a 8.12 : -7.60 0 0 0 0
W 168-19ad 0.049 se 1.42 2.59 0 0 0 _ 0
Bik mdl,stuboo e)d 0201 se 5.83 4.98 64 64 '373 319
10C-v 0.340 Se 9.86 5.97 0 0 0 0
2A 2ov 0280 se 8.12 7.60 0 0 0 �0
2A 2ov 0280 se 8.12 7.60 0 0 0 0
2A-2ov 0280 se 8.12 14.96 0 0 .0 0
W 1613-19ad 0.049 sw 1.42 2.59 0 0 0 0 '
Vy 81k wall,stu000 eiQ OJ61 sw. 5.83 4.98 0 0 '0 0
-G 10C-v �0.340 sw 9.86 5.97 0 0 0 0
r--G 2A 2ov 0280 sw 8.12 ,- 14A6 0 0 .0 0
W 1613.19ad 0.049 nw 1.42 259 0 0 0 0
'Blkwall,stucco e)d -0201 nw 5.83 4.98 0 0 6 0
2A 2ov 0280 nw, 8.12 1529 0 0 0 0
2A=2ov 0280 nw 812 1529 :0 0 % . .0 0 f
213 2fv 02W nw 8.41 18.85 0 0 0 0
2B-2fv 0290 rw 8A1 15.99 0 0 .4 0 0
213-2ry 0.340 nw 9.86 17.31 0 0 0 0
11J0... 0.600 nw 17.40 1758 0 0 0 0 �'
PI - 12C-0sw 0.001 - 2.64 1.31 0 0 0 0
. _D_ 11DO 0.3W n 11.31 11.43 0 0 0 0
-C 16830ad 0.032 - 6.93 1.69 109 109 ;•`101 184 :
F 22A tpl 0.989 - 28.68 0.00 109 14 387 0
6 'c)AEDexwrsion P : 35
Envelopeloss(gain I 1299 884
12 a) Infiltration it 223 59
b) Room ventilation 0 0
13 'Interned gains: Occupants 230 0 0
Applianoes/other 0
..Subtotal Qines6to13) 1522 944
Less exlemal load I 0 0
Lesstransfer
Redistribution
' 0
14 Subtotal 1522 944
15 Ductloads 22% 33% 331 314
Total room load 1853 1258
'Air required(dm) 84 58
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-Fim- wrYgtitsoTt^ I 2022-Apr-1816:5815
Riga-Sdhe®Universal 2021 21.0.07 RSU24015 Page 9
erstone2508CRGR1Lot38B112Waterstone2508CRGRnp Calc=MJ8 Horsefaces:NW
li
I'
I
D System Summary Job n Lot 38 Block 2 Watersto ...
�+ wrightsoft® uct �i I Date: NOVEMBER 3,2010
Entire House By. DCS
Del-AV Heating&Air Conditioning
531 Codisco Way,Sartiord,FL 32771 Phone:407-333-2665 Fax 407-333-3B53 Web:wwwdelair.com Licerse:CAC05147
III
Project Inf• •
For. Adams Homes
8521'iWaterstone Boulevard,Fort Pierce,FL34951
i
Heating Cooling
External static pressure i 0.40 in H2O 0.40 in H2O
Pressure losses 0.06 in H2O 0.06 in H2O
Available static pressure �; 0.34 in H2O 0.34 in H2O
Supply/return available pressure 0.170/0.170 in H2O 0.170/0.170 in H2O
Lowest friction rate ;i 0.230 in/100ft 0.230 in/100ft
Actual airflow 1400 cfm 1400 cfm
Total effective length(TEL) 148 ft
SupplyDetail Table
lil I
Design 'I,Htg Cig Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (dm) MM) FIR (in) (in) Mat Ln(ft) Ln(ft) Trunk
BATH 2 h 414 �i 19 11 0.445 4.0 Ox 0 VI Fx 6.4 70.0
BATI43 h 1853 84 58 0.313 6.0 Ox0 VIFx 23.8 85.0 st1
BDR M2 h 2921 132 104 OA10 6.0 Ox0 MFx 13.0 70.0
BDRM 3 c 1886 hl 81 87 0.396 6.0 Ox 0 M Fx 15.8 70.0
BDRM 4 h 3078 139 120 0.305 7.0 Ox 0 M Fx 26.3 85.0 st1
BRKFST h 1345 61 42 0.312 6.0 Ox0 VIFx 23.8 85.0 st1
DINING RM c 2788 107 129 0.399 7.0 Ox 0 VI Fx 15.1 70.0
FAMILYRMIFOYER c 2767 108 128 0.312 7.0 Ox0 VIFx 24.1 85.0 st2
FAMILYRMIFOYER-A c 2767 108 128 0.312 7.0 Ox0 VIFx 24.0 85.0 st2
KITCHEN c 1881 ` 8 87 OA36 6.0 Ox 0 VIFx 8.0 70.0
LIVING RM h 3871 175 159 0.276 8.0 Ox 0 VI Fx 38.2 85.0 st2
M.W/c c 46 1 2 0.245 4.0 Ox 0 VI Fx 38.6 100.0 SO
M.Wic h 1018 46 28 0.247 4.0 Ox 0 VIFx 37.6 100.0 st3
M.WIC II c 129 3 6 0.253 4.0 Ox 0 VI Fx 34.5 100.0 st3
MASTER BATH h 1344 61 47 0.249 5.0 Ox 0 VIFx 36.4 100.0 st3
MASTERBDRM h 5047 228 199 0.230 8.0 Ox0 VIFx 47.5 100.0 st3
UTILITY c 1404 43 65 OA57 5.0 Ox0 VIFx 4.5 70.0
Supply Trunk - • -
li1 I
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (dm) FIR {fpm) (in) (in) Material Trunk
st3 PeakAVF 338 282 0.230 620 10.0 0 x 0 VinlFlx s12
st2 PeakAVF 728 - 697 0.230 521 16.0 0 x 0 VnlFlx
st1 PeakAVF 283 220 0.305 641 9.0 0 x 0 VinlFix
1
hl
I
2022-Apr-181
-h- wrightsoft® 6:58:I7
Right Sute®Uriversal 2021 21.0.07 RSU24015 Pagel
ACCK ...erstore2508CRGR1Lot38BIIQWatersmre2508CRGRnp Calc=MJ8 Horsefaces:NW
I'
Return Branch Detail Table
Grille Htg ql TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (Cfm) FR (fpm) (in) (in) Opening(in) Mat Trunk,
rbl ox 0 1400 ';114 001 0 0 0 0 Ox 0 VlFx
wrightsoft,
2022-Apr-1 8 16:58:17
Rgft-SU�@Uriversal202l2l.O.O7RSU24016
11 1 Page 2
ACM ersbne2508CRGF;VLot38B[WWaterstorie25O8CRGF;LrLp Calc=MJ8 Housefaces:NW
• lii i
Florida Building Code, Energy Conservation, 7th Edition (2020)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 8521 Waterstone Boulevard Permit Number:
Fort Pierce,FL,34951
MANDATORY REQUIREMENTS -See individual code sections for full details.
V '� � SECTION R401 GENERAL
R401.3 Energy Performance Level(EPL)display card(Mandatory)The building official shall require that an energy performance level (EPL)
display card be completed and certifie4 by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
❑ (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The buildirg official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD.
SECTION R402 BUILDING THERMAL ENVELOPE
❑ R402.4 Air leakage(Mandatory). �i '�The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling "nits of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
I .
❑ R402.4.1 Building thermal envelopeThe building thermal envelope shall comply with Sections R402.4.1.1 and
R402.4.1.2.The sealing methohs between dissimilar materials shall allow for differential expansion and contraction.
❑ R402.4.1.1 Installation. The c'o;mponents of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required
by the code official,an approved,third party shall inspect all components and verify compliance.
❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zories 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w:g.(50 pascals).Testing shall be conducted by either
individuals as defined in Section'I553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or
an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code;
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not j'required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1.Exterior windows and doors I'freplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures.
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures.
3.Interior doors,if installed at the time of the test,shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems;if installed at the time of the test,shall be turned off.
6.Supply and return registers,'if installed at the time of the test,shall be fully open.
❑ R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where
using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the
(replace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
❑ R402.4.3 Fenestration air leakage.l,Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Lls/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
{i
4/18/2022 4:55 PM EnergyGa i ge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 5
_ I
I
I
MANDATORY REQUIREMENTS - (Continued)
I
❑R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to
open.combustion fuel burning appliance's)the appliances and combustion air opening shall be located outside the building thermal envelope or j.
enclosed in a room,isolated from insideJ6 thermal envelope.Such rooms shall be sealed)and insulated in accordance with the envelope requirements
of Table R402.1.2,where the walls,floors'and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be
fully gasketed and.any water lines and duicts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves I; :Icomplying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. I
❑R402.4.5'Recessed lighting. Recess)d luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditionedl!spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gask4lor caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls.
❑ R403.1.1 Thermostat provision(M Adatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary,heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways
f
for air distribution systems shall.be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Tovisions of this code and shall be shown to meet duct tightness criteria below.
l
Duct tightness shall be verified+ iby testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or
(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(0,(g)or(i),Florida Statutes,to be"substantially leak free"in
accordance with Section R40S. .3.
❑ R403.3.2.1 Sealed air handler Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods:
II I
1. Rough-in test:Tota
nl leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,
including the maufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise
sealed during thie est. 1
2. Postconstructiori test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire
system,including he manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test.
l
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
I''
2. Duct testingilis not mandatory for buildings complying by Section 405 of this code.Duct leakage testing is required for section
R405 compliance where credit is taken for leakage,and a duct air leakage Qn to the outside of less than 0.080(where I,Qn=
duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals)is indicated in the
compliance deport for the proposed design.
I
A written report ofl the results of the test shall be signed by the party conducting the test and provided to the code official.
❑R403.3.5 Building cavities(Mandatory)'. Building framing cavities shall not be used as ducts or plenums.
R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulatedilto a minimum of R-3.
❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that
caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause
degradation of the material.Adhesive tape shall not be permitted.
❑ ; R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). If heated water circulation systems are
i installed,they shall be in accordance with section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with
1; Section R403.5.1.2.Automatic" ontrols,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall
❑ be a dedicated return piped or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited.Controls for'
circulating hot water system)pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The
controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no
demand for hot water. 1!
❑ R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall
automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the
times when heated water is-used in the occupancy. l
jl
4/18/2022 4:55 PM EnergyGa i ge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of
I
F I
. I j
I
I
MANDATORY REQUIREMENTS - (Continued)
❑ R403.5.5 Heat traps(Mandatory). (Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the Inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 V2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies!
,(Mandatory).
❑ R403.5.6.1.1 Automatic contrjoIs. Service water-heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature
setting range shall be from 100°F to 140°F(38°C to 60°C).
❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems tol!be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of
combustion types of servi ie water-heating systems to be turned off.
R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of
❑ Table C404.2 in Chapter 4I of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate;
water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
❑ R403.5.6.2.1 Solarwat Irlheating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system ii the solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar
water-heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed atlan orientation within 45 degrees of true south.
❑ R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation
including:Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
❑ R403.6.1 Whole-house mechlanical ventilation system fan efficacy.When installed to function as a whole-house mechanical
ventilation system,fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole-house mechanical
ventilation,the air handler shall be powered by an electronically commutated motor.
❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable
Indoor Air Quality,shall be the maximum rates allowed for residential applications. j
2. No ventilation or air-(conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10
otherwise.
I
R403.7 Heating and cooling equipment.
I
R403.7.1 Equipment sizing(Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based
❑ on the equipment loads(calculated in accordance with ACCA Manual J or other approved heating and cooling calculation
1.methodologies,based on(building loads for the directional orientation of the building.The manufacturer and model number of the
outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design
' conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other
factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical
ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have
an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is
installed. I
TABLE R403.6.1
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION I AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUIV
(CFM) (CFM/WATT) (CFM)
HRV or ERV Any 1.2 cfm/watt Any
I
Range hoods Any 2.8 cfm/watt Any
In-line fan j Any 2.8 cfm/watt Any
I
Bathroom,utility room ' 10 1.4 cfm/watt <90
_ Bathroom,utility room 90 2.8 cfm/watt Any
I
For SI: 1 cfm=28.3 Umin. a. When tested in accordance with HVI Standard 916
4/18/2022 4:55 PM EnergyGa i ge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall,be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section R403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's
expanded performance data shall bellused to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation(01 entering water temperature for water-source equipment),the blower CFM provided by the expanded
performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for r"eturn side gains if the return duct(s)is installed in an unconditioned space.
i
Exceptions:
I, .
1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
r ;
I'
❑ R403.7.1.2.2 Electric resistance'furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
I
' I
❑ R403.7.1.2.3 Fossil fuel heating,equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric bumers
shall not be less than the design load calculated in accordance with Section R403.7.1.
U '� I
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. !
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
❑ C403 and C404 of the Florida Building Code,Energy Conservation—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system(c 111
ontrols(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no
precipitation is failing and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C).
Fi R403.10 Pools and permanent spa e rgy consumption(Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
!' I
❑ R403.10.1 Heaters. ? . The electric power to heaters shall be controlled by a readily accessible on-off switch that is an
integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation
of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the
power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots.
❑ R403.10.2 Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this
section. f
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
i
I
4/18/2022 4:55 PM EnergyG� ge®USA 7.0.00-FlaRes.202O FBC 7th Edition(2020) Compliant Software Page 4 of 5
, i
I
' j I
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at
Q the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Wher' more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered
energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required.
❑ R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal
efficiency of 82-percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
R403.10.5 Heat pump pool heatersl! Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
h �
❑ R403.11 Portable spas(Mandatory)-'The energy consumption of electric-powered portable spas shall be controlled by the
requirements of APSP-14.
R403.13 Dehumidifiers(Mandatory, If installed, a dehumidifier shall conform to the following requirements:
L ,
1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/kWh if the total dehumidifier capacity for the house
is less than 75 pints/day and Igreater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day.
2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air.
3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2.
4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code,Residential.
I
il•
R403.13.1 Ducted dehumidifiers. I Ducted dehumidifiers shall,in addition to conforming to the requirements of Section R403.13,
conform to the following requirements:
i
1. If a ducted dehumidifi I;r his configured with return and supply ducts both connected into the supply side of the cooling system,a b ckdraft
damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct.
2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system,
a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct.
3. A ducted dehumidifiers all not be ducted to or from a central ducted cooling system on the return duct side upstream from the
central cooling evaporator coid' j
4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6.
I�
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment(Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an
efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt.
li .
R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
I
i
I'
i I
I ;
I
,I I,
A I'
1
G
4/18/2022 4:55 PM EnergyG�auge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 5
1
IAA ,
I ;I
I '
FORM R465-2020
I I
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
I
I
Florida(Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the
Residential Simulated Performance Alternative shall include:
❑ This checklist
❑ Form R405-2020 report
❑ Input summary checklist that can be used for field verification (usually four pages/may be greater)
'I
❑ Energy Performance'Level(EPL) Display Card(one page)
� a
❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.�7
i I
❑ Mandatory Requirements (five pages)
Required prior to CO:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -one page)
I
❑ A completed 2020 Envelope Leakage Test Report(usually one page);exception in R402.4
allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to
comply with Section C402.5 i
.I
❑ If Form R405[ldct leakage type indicates anything other than "default leakage" then a completed
2020 Duct Leakage Test Report-Performance Method(usually one page)
., II
I'
I ,
i
I
i
4/18/2022 4:54:14 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 of 1
2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1 a
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
�'I
Project Name: Lot38Blk2Waterst6ne2508CRGR Builder Name: Adams Homes
Street: 8521 Waterstone Boulevard Permit Office:
City,State,Zip: Fort Pierce,FL,1'34951 Permit Number: Y
U
Owner: Jurisdiction: 661000 =
Design Location: FL,ST LUCIE_CO_INTL U
COMPONENT !. AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or jointsl;in the air barrier shall be sealed.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openingsl drop down stairs or knee wall doors to
.unconditioned attic spaces shall be sealed.
Walls The junction of tti'e foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. 1 I with a material having a thermal resistance of R-3
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
i
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/doorjambs and framing,and
and doors skylights and framing shall be sealed.
'. I
Rim joists Rim joists shalllinclude the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed tol
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered I' shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed onl
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing j
members.
Crawl space walls Exposed earth inl unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vaporjretarder with overlapping joints taped. shall be permanently attached to the crawlspace wall .
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac 3s.
kl
Recessed lighting Recessed light1 fiiztures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space sl1'all
extend behind piping and wiring
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exteriorwall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor,wall covering or
Concealed When required�:to be sealed,concealed fire sprinklers shall only be
sealed in a manner that is recommended b the manufacturer.
sprinklers � Y i
Caulking or other adhesive sealants shall not be used to fill voids
t-gan fire la
a.In addition,inspection of log walls shall'be in accordance with the provisions of ICC-400.
4/18/2022 4:55 PM EnergyGai1ge@ USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
• ,i II
EnveI!l;ope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida 'Building Code, Energy Conservation, 7th Edition
Jurisdiction: 661000 Permit#:
.Job Information �I
Builder: Adams Homes ! Community: Lot: 38/2
Address: 8521 Waterstone Boulevard
City: Fort Pierce State: FL Zip: 34951
Air'Leakage T,est.Results Passt*ng results must meet;edher`the Performance Prescriptive, or ERI'Method
OPRESCRIPTNE'METHOD The'bwli ing or dwelling unit shall be tested and.verified as having an air leakage rate of not exceeding 7 air
. .changes per hour at a pressure,of 0.2 inch w.g.(50'.Pascal6)in Climate Zones 1 and 2.,
0„ PERFORMANCE or ERI METHOD The building;or dwelling unit shah be tested and verified as having an-air leakase.rate of not exceedirg
the,selected ACH(50).value;as.shouvn on.Form R405-2020(Performance)or R406 2kiJ(ERI),section labeled as infiltration,sub-section ACH5Q.
ACH(50)sped ied on form R405-2020 Calc(Pen`ormance)or R406-2020(ERI): 6.750
l I .. m
x 60 _ 9.0;47062E30 = Method for calculating building volume:
CFM(50) Building Volume ACH(50) O Retrieved from architectural plans
PASSF-1 Code software calculated
When ACH(50) is lesslahan 3, Mechanical Ventilation installation Q Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing.Testing shall be�c'onducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section
489.105(3)(0 (g),or(i)or an approve,'d,l third party.A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration
control measures.
2.Dampers including exhaust,intake',makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control
measures. 1
3.Interior doors,if installed at the time of the test,shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems,if installed at the time of the test,shall be turned off.
71
6.Supply and return registers,if installed at the time of the test,shall be fully open.
�ITesting Company
Company Name: !� Phone:
I hereby verify that the above Ai Leakage results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification#: ! Issuing Authority:
I
4/18/2022 4:55:36 PM ,EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 1 of 1
I
' --_ ---- - --am•�.o=*a��_a�^.•=•o,.m.-^- - :"`."®`-"�y� �- L 160 M11PH OAcNC!`.
5" bath duct
to roof cap <n rS
w/ standard 70
cfm both fan <Ei.."
O U tVINh^
w. ::........._.__"._.-__..._„-, ,.5mrovii;±:'"` �"j- ai7uric:— ^-->•--TT:-,---T--. .�7:_._--.w---� _ ,.� C ._ Ui
9 --
WALL LEf
OWNER'SBEOR(ICM O q
• c C ))��( A 10ze Iw d®� 7• 'Fib 1w d ..mv t 1 �:1 10z6 llwcd 0 120 C t
-
BREAKFAST •� 7 2 `Z
1Re .se'ee +^•-`exyleaw-.-.- r,•_- - 9
a
14.8
.10
¢e, Iw5e` flub
_
it 30 x FAN'.Io R004 - -
-I E H�SCti;h -»u�,�c�t7�
a ..r--�r _. 130 IIIpI 90.n �~ 6. 10,5 iwcd
G -I170 lwcd lOz6 Iwcd 105 .y 2 6 lwad I
Of
04
o• lo ln rag I`, ® I N Oh,= 10,61wca 2�xle(brag, 10z10ra 0 4OA UtL i
I ,
_
. xe. _— 6511 ® 16 REDR00Y12 _ Q N O, C
1M
� I c� I L I A r Imo_
"
o 6 10z6 iw d >�,' 00 -w
._�..—
^1 �•B I I 490�u 2
1 5ovctR oz6 t00IIfN d 9 Io j
I lux..ROOM I I I 12x6 loved \ p �z4 Ssed ) /�:I
-t4ze lwcd140
Q mt ti
42"x42" A/C Slab j
- - -By Builder Min.
.FMYa�'"�:.0 '{I u.a•�: - :2' from Wall '
. w_.:.L.J! 4•dryer duct
ENTRY ;; _ to of
cap J.5 TON W/5KW 0240V 1PH O
w/dryv vent box 18x13 plen plallorm by Z O
bldr
5" bath duct O O
to roof cop A;' s CAR cARACE I l_ " N
w/ standard 70 I"--- ��u e� G LLJJ L0 t\j
cfm bath fan —
r..
5" bath duct 5 bath duct - Y W
to roof cap to roof cap � U F m
w/ standard 70 w/ standard 70 © to O
cfm bath fan—light cfm bath fan 0c)M W
Q O�fr
.. .w O Lt")O w I O O
NOTE TO BUBLILDE:M PROVIDE UNRESTRICTED Q NJ Z D '
1 INCH UNDERCUT BELOW
W DOORS TO HABITABLE ROOMS — --I{
Transfer ducts/grills sized in compliance
wit b Florida Residential Building code-M1602.4 t i a EA CALM z
balanced return air.
EXCEPTIONS 1-3 FLOOR PLAN r
ELEVATION•CR• .,� Lu '' 7 Z
f— Q
n. Z) Q O :D Q 0!:
Must have a minimum cieoronce of 4 inches around the oir hondler per the State Energy code. All duct has an r-6 insulation_value. co 0__ —j (n d iz�
FORM R405-2020 �I
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
�i
Project Name: Lot38BIk2Waterstone2508CRGR Builder Name: Adams Homes
Street: 8521 Waterstone Bou�levard Permit Office:
Cit
y,,State,Zip: Fort Pierce,FL,3495� Permit Number:
Owner: I Jurisdiction: 661000
Design Location: FL,ST LUCIE_CO_INTL County: St.Lucie(Florida Climate Zone 2)
II �I
1. New construction or existing New(From Plans) 10. Wall Type42047.7 sgft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1748.50 ft2
b.Frame-Wood,Adjacent R=13.0 299.17 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
11.Ceiling Types (2603.0 sgft.) Insulation Area
5. Is this a worst case? 11 No a.Under Attic(Vented) R=30.0 2523.00 ft2
11
6. Conditioned floor area above grade(ft2);' 2523 b.Knee Wall(Vented) R=19.0 80.00 ftZ
Conditioned floor area below grade(ft2)j 0 c.N/A R= ft2
7. Windows(295.2 sgft.) Description Area 12.Ducts R ft2
� a.Sup:Attic,Ret:Main,AH:Main 6 504.6 I
a. 0-Factor: Dbl,U=0.28 161.89 ft2
SHGC: SHGC=0.22
b. U-Factor: Dbl,U=0.28 70.92 ft2 13.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.20 a.Central Unit 42.0 SEER:15.00
c. U-Factor: Dbl,U=0.34 41.56 ft2
SHGC: SHGC=0.22 14.Heating systems kBtu/hr Efficiency
Area Weighted Average Overhang Depth?. 6.173 ft. a.Electric Heat Pump 42.0 HSPF:8.50
Area Weighted Average SHGC: ii. 0.214
8. Skylights Area
i
c. U-Factor:(AVG) N/A �; ft2 15.Hot water systems
SHGC(AVG): N/A it a.Electric Cap:40 gallons
9. Floor Types (2523.0 sgft.) Ilnsulation Area EF:0.940
a.Slab-On-Grade Edge Insulation ;1R=0.0 2523.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A I� �R_
ft2 16.Credits Pstat
Glass/Floor Area: 0.117
Total Proposed Modified Loads: 68.36 PASS
Total Baseline Loads: 71.02
1 hereby certify that the plans and speicifications covered by Review of the plans and O�TIiE STg1,
this calculation are in compliance with-the Florida Energy specifications covered by this
Code. Icalculation indicates compliance
1 with the Florida Energy Code.
PREPARED BY: �Y Ni
this Henry Before construction is completed
April 18, 2022 I� this building will be inspected for DATE: p 9 p .
compliance with Section 553.908
hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florida Energy Code. G'Otj:
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE: I
- Compliance requires certification';by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier•and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.75 ACH50(R402.4.1.2).
r
� I
i
4/18/2022 4:54 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition,(2020) Compliant Software Page 1 of 5
I
g i
SI
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT j
[ 'I
Title: Lot38Blk2Waterstone2508CR Bedrooms: 4 Address Type: Lot Information
Building Type: User Conditioned Area: 2523 Lot# 38/2
Owner Name: Total Stories: 1 Block/Subdivision: Waterstone
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Adams Homes Rotate Angle: 0 Street: 8521 Waterstone B lule
Permit Office: Cross Ventilation: No County: St.Lucie
Jurisdiction: 661000 Whole House Fan: No City,State,Zip: Fort Pierce,
Family Type: Detached FL, 34951
i
New/Existing: New(From Plans)
Comment:
i
ij CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
v Design Location 1 MY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,ST_LUCIE_CO INTL FL VER10 BEACH MUNI 39 90 70 75 299 58 Medium
BLOCKS
Number Name ;, 'I Area Volume
r
1 Block1 2523 22202.4
i
I
SPACES
Number Name + Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled ;Heated
1 Main 1`2523 22202.4 Yes 5 4 1 Yes Yes -Yes
FLOORS j
# Floor Type III Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulat'o Main 242.9 ft 0 2523 ft2 ---- 0.32 0 0.'68
ROOF
`/ ;I Roof Gable Roof Rad Solar SA Emitt Emitt Deck, Pitch
V # Type ,Materials Area Area Color Barr Absor. Tested Tested Insul.! (deg)
1 Gable or Shed Complosition shingles 2821 ft2 630 ft2 Medium N 0.85 N 0.9 No 0 26.57
h ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
�r
1 Full attic Vented 300 2523 ft2 N N
I� CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Knee Wall(Vented) j Main 19 Blown 20 ft2 0.11 Wood
r
2 Knee Wall(Vented) Main 19 Blown 20 ft2 0.11 Wood
3 Knee Wall(Vented) Main 19 Blown 20 ft2 0.11 Wood
4 Knee Wall(Vented) Main 19 Blown 20 ft2 0.11 Wood
i
5 Under Attic(Vented) I Main 30 Blown 2523 ft2 0.11 Wood
P
I
I
I
4/18/2022 4:54 PM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 5
r ',
4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT I
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w
_ 1 NE Exterior Concrete Block-Int Insul Main 4.1 57 3 8 0 458.0 ft2 0 0 0.6 0
2 E Exterior Concrete Block-Int Insul Main 4.1 4 11 10 0 49.2 ft2 0 0 0.6 0
i
_3 SE Exterior Concrete Block-Int Insul Main 4.1 61 0 8 0 488.0 ft2 0 0 0.6 0
_4 SW Exterior Concrete Block-Int Insul Main 4.1 57 0 8 0 456.0 ft2 0 0 0.6 0
_ 5 NW Exterior Concrete Block-Int Insul Main 4.1 37 2 8 0 297.3 ft2 0 0 0.6 0
6, - Garage Frame-Wood Main 13 29 11 10 0 299.2 ft2 0 0.23 0.01 0
!I •I '
I DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
I, Ft In Ft In
i
1 NE Insulated Main None .25 2 4 6 8 15.6 ftz
2 NW Insulated Main None .25 3 6 8 20 ft2
3 - Wood ' Main None .25 2 8 6 8 1 7.8 ft2
WINDOWS
1 Orientation shown is the entered,Proposed orientation.
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 NE 1 Vinyl Low-E Double Yes 0.28 0.22 Y 9.8 ft2 1 ft 4 in Oft 11 in Drapes/blinds Exterior 5
2 NE 1 Vinyl Low-E Dlouble Yes 0.28 0.22 Y 16.2 ft2 1 ft 4 in Oft 11 in Drapes/blinds Exterior 5
3 E 2 Vinyl Low-E IDouble Yes 0.28 0.22 N 12.5 ft' 12 ft 1 in 0 ft 3 in Drapes/blinds Exterior 5
4 SE 3 Vinyl Low-E Dlouble Yes 0.34 0.22 N 17.8 ft' 10 ft 2 in 0 ft 7 in None None
5 SE 3 Vinyl Low-E Dlouble Yes 0.28 0.22 Y 12.5 ft' 7 ft 2 in 0 ft 3 in Drapes/blinds Exterior 5
6 SE 3 Vinyl Low-ElDouble Yes 0.28 0.22 N 30.0 ft2 10 ft 2 in 0 ft 4 in Drapes/blinds Exterior 5
7 SE 3 Vinyl Low-E,,Double Yes 0.28 0.22 N 48.6 ft' 1 ft 4 in 1 ft 2 in Drapes/blinds Exterior 5
8 SW 4 Vinyl Low-E Double Yes 0.34 0.22 N 17.8 ft' 23 ft 8 in 0 ft 7 in None None
9 SW 4 Vinyl Low-E IDouble Yes 0.28 0.22 N 32.4 ft' 1 ft 4 in Oft 11 in Drapes/blinds Exterior 5
10 NW 5 Vinyl Low-E Double Yes 0.28 0.2 N 32.4 ft' 7 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5
11 NW 5 Vinyl Low-ElDouble Yes 0.28 0.2 N 38.5 ft' 1 ft 4 in 2 ft 10 in Drapes/blinds Exterior 5
12 NW 5 Vinyl Low-E Double Yes 0.29 0.21 N 7.5 ft2 11 ft 10 in 0 ft 0 in None None
13 NW 5 Vinyl Low-E Double Yes 0.29 0.21 N 13.3 ft2 11 ft 10 in 2 ft 2 in Drapes/blinds None
I
14 NW 5 Vinyl Low-EDouble Yes 0.34 0.22 N 6.0 ft2 1 ft 4 in 1 ft 2 in None None
l
GARAGE
# Floor Area 11 'J Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation I
1 620 ftz 620 ft2 72.737 ft 8 ft 1
,1
I
r
I '
4/18/2022 4:54 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method l SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) •i .000377 2497.8 137.04 257.27 .1266 6.75
HEATING SYSTEM
# System Type I Subtype Speed Efficiency Capacity Block Ducts
1 Electric Heat Pump/ i; Split Singl HSPF:8.5 42 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Singl SEER: 15 42 kBtu/hr cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Ii Garage 0.94 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage I
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftZ 1
i .I
li DUCTS
/ —Supply— �, —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 5041.E ft Main 126.15 Default Leakage Main (Default) (Default) 1 ; 1
TEMPERATURES
Programable Thermostat:Y h Ceiling Fans:
Cooling Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Heating Jan H Feb Mar E APr f IM
aY f Jun Jul 4 Auf SeP Oct Nov Dec
Vent!n Jan Feb Mar [X,Apr [ May [ Jun Jul [ Aug [ Se Oct Nov Dec
i
I, •
f
I
i
i
it
I ;
4/18/2022 4:54 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 5
i'
i
I
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 jl 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 it 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 �„ 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
I
Mass Type f, Area Thickness Furniture Fraction Space
Default B Ibs/s .ft. p ,� 0 ft. 0 ft 0.3 Main
u ,
1
I.
i
I
I�
I,
II
i
i
1
I
I
I �I
it I i
li
II ,
' hhh
i
I
I
If II
I�
I �
Ij I
I•
1,
I
I
I;
I
I I
4/18/2022 4:54 PM EnergyGaube®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 5
I,
� I
FORM R405-2020
L :
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
�I .
The lower the EnergyPerformance Index, the more efficient the home.
8521 Waterstone Boulevard, Fort Pierce, FL, 34951
1. New construction or existing li : New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family 1: Detached a.Concrete Block-Int Insul,Exterior R=4.1 1748.50 ft2
b.Frame-Wood,Adjacent R=13.0 299.17 f:
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
11.Ceiling Type and insulation level Insulation Area
5. Is this a worst case? II No a.Under Attic(Vented) R=30.0 2523.00 ft2
i
6. Conditioned floor area(ft2) II 2523 b.Knee Wall(Vented) R=19.0 80.00 ft2
7. Windows" Description Area c.N/A R= ft2 !
a. U-Factor: Dbl,U=0.28 161.89 ft2 12.Ducts,location&insulation level R ft2
a.Sup:Attic,Ret:Main,AH:Main 6 504.6
SHGC: SHGC=0.22
b. U-Factor: Dbl,U=0.28 70.92 ft2 J
SHGC: SHGC=0.20 I; 13.Cooling systems kBtu/hr Efficiency 1
c. U-Factor: Dbl,U=0.34 ! 41.56 ft2 a.Central Unit 42.0 SEER:15.00
SHGC: SHGC=0.22 ; ;I
d. U-Factor: other(see details) 20.83 ft2
1I • 14.Heating systems kBtu/hr Efficiency
SHGC: other(see details1.: a.Electric Heat Pump 42.0 HSPF:8.50
Area Weighted Average Overhang Depth. 6.173 ft.
Area Weighted Average SHGC: ! 0.214
8. Skylights Description q Area 15.Hot water systems
2 a.Electric Cap:40 gallons
a. U-Factor(AVG): N/A ft2 EF:0.94
SHGC(AVG): N/A b. Conservation features
9. Floor Types j Insulation Area None
a.Slab-On-Grade Edge Insulation �, R=0.0 2523.00 ft2 Credits(Performance method) Pstat
b.N/A R= ft2
c.N/A R= ft2
!
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded) yQCHEST`�TF�
in this home before final inspection. iOtherwise, a new EPL Display Card will be completed ',,,'''%' ZZ
based on installed Code compliant features.
Builder Signature: Date: f -
Address of New Home: City/FL Zip: . - 5 '
Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM)incentives if yot1J' 'lobtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R3031.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/18/2022 4:54 PM EnergyG'auge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 1
I
I
I ' �
2A�3 a�zZ
Manual S Compliance Report Job: Lot 38 Block 2Waterstone...
- wrightsoft® Date: NOVEMBER 3,2010
Entire House By. Dcs
Del-Air Heating &Air Conditioning
531 Codisco Way,Sar{ord,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:wwadelair com Licerse:CAC05147
Project Information
For. Adams Homes
i;8521 Waterstone Boulevard,Fort Pierce,FL34951
Cooling Equipment
Design Conditions j
Outdoor design DB: 90.4°F Sensible gain: 30293 Btuh Entering coil DB: 76.5-F
Outdoor design WB: 77.4°F Latentgain: 5175 Btuh Entering coil WB: 63.3°F
Indoor design DB: 75.0°F Total gain: 35467 Btuh
Indoor RH: 50% Estimated airflow: 1400 dm
i
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SpIitASHP
Manufacturer. Carrier j Model: 25HBC542AP03+FB4CNP048L00
Actual airflow: 1400 cfm
Sensible capacity: 33600 Bti!h 111%of load
Latent capacity: 6637 Btuh 128%of load
Total capacity: 40236 Bt'I h 113%of load SHR: 84%
Heating Equipment
Design Conditions
Outdoor design DB: 41.0°F C Heat loss: 31052 Btuh Entering coil DB: 69.5°F
Indoor design DB: 70.0°F
V
Manufacturer's Performance;Data at Actual Design Conditions
Equipmenttype: SpIitASHP I'
Manufacturer. Carrier Model: 25HBC542AP03+FB4CNP048L00
Actual airflow: 1400 1 f n
Output capacity: 38491 Btuh 124%of load Capacity balance: 33 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer. Model:
Actual airflow: 1400 t fm
Output capacity: 8.3 kW 91%of load Temp.rise: 18 OF
Meets all requirements ofACCA Manual S.
-�- wrightsoft- 2022-Apr-1 8 16:58:15
i� Right Sul universal 2021 21.0.07 RSU24015 Page 1
�� ...erstore2508CRGR?Lot38Blk2Waterstone2508CRGRnp Calc=MJ8 Honsefaces:NW
I
I
Corn 1i onent Constructions Job: Lot 38 Block 2 Watestone...
- +- wrightsoft® p Date: NOVEMBER 3,2010
Enfire House By. DCs
Del-A!,, ,Heating&Air Conditioning
531 Codisoo W ay,Sanford,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:mmdelair.00m License:CAC05147 `
IlJ I
Project • •
For. Adams Homes
8521 Waterstone Boulevard,Fort Pierce,FL34951
j
lip
Design . . .
Location: Indoor. Heating Cooling
St Lucie Co Intl,FL,US Indoor temperature(OF) 70 75
Elevation: 26 ft r Design TD(OF) 29 15
Latitude: 280N Relative humidity(%) 30 50 j
Outdoor: Heating Cooling Moisture difference(grAb) 2.4 56.91
Dry bulb(OF) 41 90 Infiltration:
Daily range(OF) - 15 ( L ) Method Simplified
Wet bulb(OF) - 77 Construction quality Average
Wind speed(mph) 1 .15.0 7.5 Fireplaces 0
Construction descriptions Or Area Uaralue Insul R Htg HTM Loss Clg HTM Gain
112 BhMIWF fEMBtuh Bhdff Bbih Btuhrft' Btuh
Walls
1613-19ad:Knee wall,asphalt shingles roof'niat,r-19 kw ins,1/2"gypsum ne 20 0.049 19.0 1.42 28 2.59 52
board int fnsh se 20 0.049 19.0 1.42 28 2.59 52
sw 20 0.049 19.0 1.42 28 2.59 52
nw 20 0.049 19.0 1.42 28 2.59 52
f all 80 0.049 19.0 1.42 114 2.59 207
Blk wall,stucco ext,r-4 ext bd ins,8"thk,1/2"gypsum board int fnsh ne 416 0.201 4.1 5.83 2427 4.98 2075
e 37 0.201 4.1 5.83 216 4.98 I184
se 379 0.201 4.1 5.83 2210 4.98 �1889
sw 406 0.201 4.1 5.83 2366 4.98 2022
nw 179 0.201 4.1 5.83 1045 4.98 I893
all 1418 0.201 4.1 5.83 8264 4.98 7065
Partitions
12C-0sw..Frm Ymll,1/2"gyp.bd ext,r-13 ca' ins, 1/2"gypsum board int 281 0.091 13.0 2.64 742 1.31 369
fnsh,2'5W'wood fnn,16"o.c.stud
I
I,
Windows
2A 2ov:2 glazing,dr lowe outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" ne 10 0.280 0 8.12 79 16.4 160
thk,NFRC rated(SHGC=0.22);50%drapes' medium;1.33 ft overhang
(3.17 ft window ht,0.88 ft sep.);6.67 ft he,. ht
2A 2ov:2 glazing,dr lowe outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" ne 16 0.280 0 8.12 131 16.4 265
thk NFRC rated(SHGC=0.22);50 drapes,medium;1.33 ft overhang
(5.25 /o ft window ht,0.88 ft sep.);6.67 ft head ht I sw 32 0.280 0 8.12 263 14.5 468
I
I; all 49 0.280 0 8.12 394 15.1 733
2A-2ov:2 glazing,dr lowe outr,air gas,vnl hm mat,cir ,innr,1/4"gap,1/8" a 13 0.280 0 8.12 102 7.60 95
thk NFRC rated(SHGC=0.22);50%drapes,medium;12.1 ft overhang(5
ft window ht,0.29 ft sep.);6.67 ft head ht
10C-v:2 glazing,dr lowe outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" se 18 0.340 0 9.86 175 5.97 106
thk;NFRC rated(SHGC=0.22);50%drapes!medium;10.17 ft overhang
(6.67 ft window ht,0.58 it sep.);6.67 ft head ht
i
ti -Fk- wrightsoft- 2022-Apr-1816:15
Right Sute®Uriversal 2021 21.0.07 RSU24015 Page 1
ACC ...erstone2508CRGR1Lot38BIIQWaterstgne2508CRGRnp Calc=MJ8 Homefaces:NW
11 I
I
L
2A 2ov:2 glazing,dr ,lowe outr,air gas,vnl fret mat,dr innr, 1/4"gap,1/8" se 13 0.280 0 8.12 102 7.60 95
thk;NFRC rated(SHGC=0.22);50%drapes,.medium;7.17 ft overhang(5
ft window lit,0.29 ft sep.);6.67 ft head lit
2A-2ov:2 glazing,dr lowe outr,air gas,vnl frm mat,dr innr,1/4"gap, 1/8" se 30 0.280 0 8.12 244 7.60 .228
thk;NFRC rated(SHGC=0.22);50%drapes,medium;10.17 ft overhang
(5 ft window lit,0.33 ft sep.);6.67 ft head lit
I
2A-2ov:2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" se 49 0.280 0 8.12 394 15.0 1726
thk;NFRC rated(SHGC=0.22);50%drapes,medium; 1.33 ft overhang
(5.25 ft window lit,1.17 ft sep.);6.67 ft head t
10C v:2 glazing,dr lowe outr,air gas,vnl fret mat,cir innr,1/4"gap,1/8" sw 18 0.340 0 9.86 175 5.97 106
thk;NFRC rated(SHGC=0.22);50%drapes,;medium;23.67 ft overhang
(6.67 ft window lit,0.58 ft sep.);6.67 ft head lit
2A 2ov:2 glazing,dr lowe outr,air gas,vnl fr n mat,cir innr,1/4"gap,1/8" nw 32 0.280 0 8.12 263 15.3 495
thk;NFRC rated(SHGC=0.20);50%drapes„Imedium;7 ft overhang(5.25
ft window lit,0.48 ft sep.);6.67 ft head lit
2A-2ov:2 glazing,cir lowe outr,air gas,vnl W, mat,cir innr,1/4"gap,1/8" nw 39 0.280 0 8.12 313 15.3 589
thk;NFRC rated(SHGC=0.20);50%drapes,medium; 1.33 ft overhang
(6.25 ft window lit,2.85 ft sep.);6.67 ft head ht
� 1
2B-2fv:2 glazing,dr lowe outr,air gas,vnl frm mat,dr innr,1/4"gap, 1/8" nw 8 0.290 0 8.41 63 18.9 141
thk;NFRC rated(SHGC=0.21); 11.83 ft overhang(1.5 ft window lit,0 ft
sep.);6.67 ft head ht
2B 2fv:2 glazing,cir lowe outr,air gas,vnl frm mat,dr innr, 1/4"gap,1/8" nw 13 0.290 0 8.41 112 16.0 213
thk;NFRC rated(SHGC=0.21);50%drapes,medium;11.83 ft overhang
(6.67 ft window lit,2.13 ft sep.);6.67 ft head lit
2B-2fv:2 glazing,cir lowe outr,air gas,vnl frril mat,dr innr,1/4"gap,1/8" nw 6 0.340 0 9.86 59 17.3 104
thk;NFRC rated(SHGC=0.22);50%drapes,medium;1.33 ft overhang(1
ft Wridow lit,1.17 ft sep.);6.67 ft head lit
I'
ti
Doors
11JO:Door,mtl fbrgl type ne 16 0.600 6.3 17.4 272 17.6 275
nw 20 0.600 6.3 17.4 348 17.6 352
all 36 0.600 6.3 17.4 620 17.6 626
11 D0:Door,wd sc type n 18 0.390 0 11.3 201 11.4 203
i
Ceilings
1613-30ad:Attic ceiling,asphalt shingles ro If'inat,r-30 veil ins,1/2" 2526 0.032 30.0 0.93 2344 1.69 4268
gypsum board int fnsh
4
Floors
22A4pl:Bg floor,light dry soil,on grade depth 243 0.989 0 28.7 6967 0 0
II
I'
r,
I.
I
I.
I
I
wrilghtsoft® 2022-Apr-1816:58:15
RigftSyte®Uriversal202121.0.07RSU24015 Pege2
�� ...erstone2508CRGR1Lot38Bll2Waterstone2508CRGRnp Calc=W8 Housefaoes:NW
Pro ect Summa Job: Lot 38 Block 2 Waterstone...
-�+ wrightsoft, ry Date: NOVEMBER 3,2010�
Entire House By. DCs
Del-AW Heating&Air Conditioning
I
531 Codisco Way,Sarford,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:wwwdelair.com License:CAC05147
Project • •
For. I;Adams Homes
I'8521 Waterstone Boulevard,Fort Pierce,FL 34951
Notes: kiJ ARVSD 6/13/13,RVSD 8-21-15 JA,L.S. 2-4-21 VWK,
Rvsd Window numbers 4.15.2022 RH
I'
Design Information
Weather. St Lucie Co Inti,FL,US
i
Winter Design Conditions Summer Design Conditions
Outside db 41 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 29 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 57 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure i, 25506 Btuh Structure 22727 Btuh
Ducts I' 5546 Btuh Ducts 7565 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification I 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 31052 Btuh Use manufacturer's data y
Rate/swingg multipplier 1.00
Infiltration Equipmentsensible load 30293 Btuh
Method I, Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3291 Btuh
j Ducts 1884 Btuh
Central vent(0 cfm) 0 Btuh
Heatingg Cooling (none)
Area(fF) 1 2523 2523 Equipment latent load 5175 Btuh
Volume(ft) ,I 22232 22232
Air changesthour 0.32 0.16 Equipment Total Load(Sen+Lat) 35467 Btuh
Equiv.AVF(cfm) i! 119 59 Req.total capacity at 0.75 SHR 3.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier ;� Make Carrier
Trade CARRIER Trade CARRIER
Model 25HBC542AP03' Cond 25HBC542AP03
! AHRI ref 204837283 Coil FB4CNP048L00
i, AHRI ref 204837283
Efficiency 8.5 HSPF Efficiency 12.5 EER,15 SEER
Heating Input Sensible cooling 31500 Btuh
Heating output 42000 Btuh @47°F Latentcooling 10500 Btuh
Temperature rise 27 OF Total cooling 42000 Btuh
Actual airflow 1400 cfm Actual airflow 1400 cfm
Airflowfactor 0.045 cfm/Btuh Airflowfactor 0.046 chi/Btuh
Static pressure 0.40 in H2O Static pressure 0.40 in H2O
Space thermostat ! Load sensible heat ratio 0.85
Capacity balance point=33 OF,
Backup:
Input=8 kW, Output=28165 Btuh,100 AFUE
Calculations approved byACCAto meet all requirements of Manual J 8th Ed. j
-�- wrigFrrtsoft- 2022-Apr-1816:58:15
�. � w!- Rigtt SUte®Uriversal 2021 21.0.07 RSU24015 Page 1
/CCA ...erstore2508CRGR\Lot38BIIQWaterstone2508CRGRnp Calc=1418 Horsefaces:NW
I
I
I
- - OVE wrightsoft' RightW@ Worksheet Job: Block 2 Waterstone 25...
Entire House Date: NOVEMBER 3,2010
'If By. DCS
Del-Air it Heating &Air Conditioning
I
531 Codisco W ay,Sariord,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:wvmdelair.com License:CAC05147
1 Room name Entire House MASTER BDRM
2 Exposed wall 242.9 It 41.0 ft
3 Room height 8.8 it 8.0 ft heaU000l
4 Room dimensions i' 14.0 x 18.0 ft
5 Room area 2525.9 ft 252 252.0 fF
Ty Construction U-value ,� Or HTM Area (tt=) Load Area (fF) Load
number (Btuhr-iF) (BtuhflF) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cod Gross NIP/S Heat Cool
I.9
6 W ` 1613-.19ad 0.049 ne 1.42 2.59 20 - 20 28 52 0 0 0 0.
Blk wall,stucco eA 0201 ne 5.83 4.98 458 416 2427 2075 144 144 839 718
2A-2ov 0.280 ne 8.12 16.38 10 0 79 160 0 0 0 0
2A-2ov 0280 ne 8.12 16.38 16 0 131 265 0 0 0 0
11 11J0 0.600 ne 17.40 17.58 16 16 272 275 0 0 0 0
yJ, Blk wall,stuom ext 0201 a 5.83 4.98 49 37 216 184 0 0 0 0
T_G 2A-2ov 0280 e_ 8.12 7.60 13 13 101 95 - 0 _ 0 0 0
W 16B-19ad 0.049 se 1.42 2.59 20 20 28 52 0 0 0 I-0
Bik wall,stuom ext 0201 se 6.0 4.98 . 488 379 2210 1889 112 80 464 397
10C-v 0.340 se 9.86 5.97 18 18 175 106 0 0 0 0
2A-2ov 0280 se 8.12 7.60 13' 13 101 95 0 0 0 0
2A-2ov 0280 se 8.12 7.60 30 30 244 228 0 0 0 0
2A 2ov 022W se 8.12 14.96 49 9, 394 726 32 6 263 484
W 1613-19ad 0.049 sw 1.42 _ 2.59 20 20 28 52 0 0 0 0
IN Bik wall,sb=e)d 0A. 1 sw 5.83 4.98 456 406 2366 2022 72 54 316 2170
10C-v ONO sw 9:86 5.97 18 • 18 175 106 18 18 175 106
2A-2ov 0280 sw 8.12 _ _14.46 32 8 263 468 0 0 0 0
W 1613-19ad 0.'049 nw 1.42 2.59 20 20 28 52 0 0 0 0
Blk wall,stuom ext 01261 nw 5.83 4.98 297 179 1045 893 0 0 0 b
2A 2ov 0280 nw 8.12 1529 32 0 263 495 0 0 0 0
2A-2ov, 0280 nw 8.12 1529 39 0 313 589 0 0 0 0
2B-2fv 0290 nw 841 •18.85 8 0 63 141 0 0 0 0
2B-2fv 0;2W nw 8A1 15.99 13 0 112 -213 0 0 0 0
28.2ry ONO nw 9.86 - 17.31 6 0 59 104 0 0- 6 0
11J0 0:600 nw 17.40 17.58 20 20 348 352 '` 0 0 0 0
P 12C-Osw 0'091 - 2.64 1.31 299 281 742 369 0 0 0 0
11DO 660 n 11.31 11.43 18 18 201 203 0 0 0 0
C 16B730ad 0:032 - 0.93 1.69 2526 2526 2344 4268 252 252 234 426
F 22A-tpl 0.,989 - 28.68 0.00 2526 243 6967 0 252 41 _ 1176 0
i
-
6 c)AED excursion 444 I1121
Envelope loss/gain I, I 21727 16974 3468 2522
12 a) Infiltration 3779 1003 678 1180
b) Room ventilation 0 0 0 ( 0
13 Internal gains: Ooorpants @ 230 5 1150 1 230
Appliandestoiher 3600 b00
Subtotal Qines 6 to 13) 25506 22727 4145 3232
Less eAemal load 0 0 0 10
Lesstransfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 25506 22727 4145 3232
15 Dud loads 22% 33% 5546 7565 22% 33% 901 1076
Total room load 31052 30293 5047 4308
Air required(dm) 1400 1400 228 199
Calculations approved bVACCAto meet all requirements of Manual J 8th Ed.
-F4- wrigtitsoft- i 'I 2022-Apr-1816:58:15
�� Right SuteOUriversal2021 21.0.07 RSU24015 Page 1
ersbrie2508CRGRIot38BIIQWaterstmre2508CRGRnp Calc=MJ8 Hoisefeoes:NW
I '
-�- Job: Lot 38 Block 2 Waterstone 25
wrightsoft Right-M Worksheet
...
1 Data: NOVEMBER 3,2010
Entire House
By. DCS
Del-Air Heating &Air Conditioning
I'II
531 Codisco Way,Sanford,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:wwwdelair.com Licerse:CAC05147
I ,
1 Room name S M WIC M WIC II
2 Eiposedvdi 8.5 It 0 ft
3 Room height 8.0 It heatl000l 8.0 ft heat/cool
4 Room dimensions 7.0 x 8.5 ft 7.0 x 8.5 ft
5 Room area 59.5 fF 59.5 fP
Ty Construction U-value ., Or HTM Area (fl-) Load Area (fF) Load
number (BWhlft-SF) (Btuhlftz) or perimeter (ft) (BWh) or perimeter (ft) (BWh)
Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cool
6 W _ :16E09ad 0.049 ne 1.42, 2.59 ,_ 0 6- 0 0 0 0 0 ;-0
V�/ Blk wall,sW000 ext 020;1 ne 5.83 4.98 68 68 396 339 0 0 0 0
__G 2A-2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
(I-_-( 2A-2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
11 p 11JO 0.600 ne 17.40 17.58 0 0 0 0 0 0 0 0
V�1 Blk wall,stu=ex( 0201 a 5.83 4A 0 0 0 0 0 0_ 0 0
:G 2A2ov _. 0280 a 8.12 7.60 0 0 0 0 0 0 0 .0
W 1613-1gad 0.049 se 1.42 2.59 0 0 0 0 0 0 0 0
Blkmail-stu000-e)d, 02d1 se 5.83 4.98 0 . 0 0 0, 0 0 0 0
IOC-v 0.3k0 se 9A 5.97 0 0 0 0 0 ,o 0 0
2A-2ov 0280 se 8.12 7.60 0 0 0 0 0 0 0 0
2A-2ov 0280 se 8.12 7.60 0 0 0 0 0 .0 0 0
2A-2ov 0280 se 8.12 14.96 0 0 0 0 _ 0 0 0 ;"0
.W 1613-19ad O.g49 sw 1.42 2.59 0 0 0 0 0 0 0 0
yJ Blk wall,ilu000 ext 0201 sw 5.83 4.98 0 ' 0 0 0 0 0 0 0
IL-_-GG 10C-v 0.340 sw 9.86 5.97 0 0 0 0 0 0 0 0
2A-2ov 0280 sw 8:12 14.46 0 0 0 0 0 0 0 0
W 1613-19ad 0.049 nw 1.42 Z59 0 0 0 0 0 0 0 1 0
Blk wall,sWaoo e)d 6201 nw 5.83 4.98 0 0 0 0 - 0 0 "0 0
2A 2ov 0280 nw 8.12 -1529 0 0 0 0 0 0 0 0
2A 2ov 0280 nw 8.12 1529 0 0 0 0 0 0 0 ,0
213-2fv 0290 nw 8.41 18.85 0 0 0 0 0 0 0 0
2B-2fv 0290 rnv 8.41, 15.99 0 0 0 0 0 '0 0 j 0
213-2fv 040 nw 9.86 17.31 0 0 :0 0 0 0 0 0
11J0 0.'600 nw 17.40 17.58 .0 0 0 0 0 0 0 0
PI - 12C-Osw 0.091 - 2.64 1.31 0 0 0 0 0 0 0 0
�-_ D 11DO 0.'* n 11.31 11.43 0 0 0 0 0 0 0 1 0
C 161330ad 0032 - 0.93 1.69 60 60 55 101 , 60 60 55 101
F 22A-fpl. 0.989 - 28.68 0.00 60 9 244 0 60 0 0 0
i
6 c)AEDwcursion -17 I -4
Envelope loss/gain 695 422 55 197
12 a) Infiltration 141 37 0 I 0
b) Room ventilation 0 0 0 0
13. Internal gains: Occupants @ 230 0 0 0 I 0
Appliano: pother 0 0
Subtotal Qines 6 to 13) 836 460 55 97
i
Less eAsmal load 0 0 0 0
Less transrer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 836 460 55 197
15 Dudloads 22% 33% 182 153 220/6 33% 12 32
Total room load 1018 613 67 129
Airrequired(dm) 46 28 3 6
1
Calcui'a ions approved byACCAto meet all requirements of Manual J 8th Ed.
-�}.� wrilgF�tsoTt- 1 2022-Apr-1816:58:15
.-�A ^� -�^•- Wt Su glte®Uriversal 2021 21.0.07 RSU24015 Page 2
erstone2508CRGR1Lot38BIIQWaterstdne2508CRGRnp Calc=M18 Hoisefaces:NW
I �
-t wrigntsoft Right-J®Worksheet
Job: Lot 38 Block 2 Waterston 25...
Entire House Date: NOVEMBER 3,2010
By. DCS
Del-Air Heating &Air Conditioning
531 Codisce Way,Sarthrd,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:wwvcdelair.mm License:CAC05147
1 Room name MASTER BATH K W/C
2 Exposed wall 10.5 it 0 ft
3 Room height 8.0 it heat/cool 8.0 ft heaUwol
4 Room dimensions 1.0 x 126.0 ft 3.5 x 6.0 ft
5 Room area 126.0 ftx 21.0 ft2
Ty Construction U-value Or HTM Area OF) Load Area (fF) Load
number (Btihd2_F) (BtuhflF) or perimeter (it) (BWh) or perimeter (ft) (BWh)
i
Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cool
6 W 1613-19ad 0.049 ne 1.42 2.59 0 0 0 0 0 .6 6 0
V�j Blk vrall,stucco ext 0201 ne 5.83 4.98 84 74 433 370 0 0 0 0
2A-2ov 0280 ne 8.12 16.38 10 0 79 160 0 0 0 0
2A-2ov 0200 ne 8.12 16.38 0 0 0 0 0 0 0 0
11 11,10 0.600 ne 17.40 17.58 0 0 0 0 0 0 0 0
V�! Blk vsli,slucco ext 0 201 a 5.83 4:98 0 0 0 0 0 0 0 0
!. , G 2A2ov _ 02,80 a 8.12 7.60 0 0 0 .0 0 '0 0 ,; 0
W 1613-19ad 0.049 se 1.42' 2.59 0 0 0 _ 0 0 0 0 0
Blk wall,stucco ext 0201 se 6.83 4.98 0 0 0 0 0 0 0 0
10C-v 0.'3 se 926 5.97 0 . 0 0 0 0 0 0 0
2A-2ov, 0280 se 8.12 7.60 0 0 0 0 0 0 0 0
2A-2ov 0280 se 8.12 7.60 0 0 0' 0 0 0 0 0
2A-2ov, 0280 se 8.12 14.96 .0 0 0 0 0 0 0 -0
W 1613-19ad 0.049 sw 1.42 2.59 0 0 0 0 0 0 0 0
V,V Blk well,stucco ext 0261 sw 5.83 4.98 0 0 0 0 0 0 0 0
♦-G 10C-v ONO sw 9.86 5.97 0 6 0 0 0 0 0 0
G 2A-2ov 0280 sw 8.12 - 14.46 0 0 0 .0 0 0 0 0
W 168-19ad 0.049 nw 1.42 2.59 0 0 0 0 0 0 0 _ 0
BIk wall,stu 03 eid 0201 rmw 6.83 4.98 0 6 0 0 0 0 0 0
2A 2ov 0280 nw 8.12 - 1529 0 0 0 0 0 0 0 i 0
2A 2ov 0280 nw 8.12 1529 0 0 0 0 0 0 0 i 0
28-2ry 0290 nw 8.41 18.85 0 0 0 0 0 0 0 0
213-21v 0:290 nw 841 15.99 0 0 0 0 0 0 " 0 0
2B•2fv 0* nw 9.86 17.31 0 0 0 0 0 0 0 t 0
11JO 0:600 nw 17.40 17.58 0 0 0 0 0 0 _ 0 10
P 12C-0sw 0,091 - 2.64 1.31 0 0 0 0 0 0 0 0
11DO _ 060 n 11.31 11.43 0 0 0 0 0 0 0 0
C 16630ad 0:032 - 0.93. ].69 126 126 117 213 21 21 19 35
F 22A-tp1 0.989 - 28.68 0.00 126 11 301 0 21 0 0 0
l
!
6 c)AED excursion I• -28 I -1
Envelope loss/gain ; 930 715 19 134
12 a) Infiltration 174 46 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Applial'ow0ther 0 0
Subtotal(lines 6 to 13) 1 1104 761 19 134
Less extemalload ! 0 0 0 0
Lesstransfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1104 761 19 134
15 Ductloads q 22% 33% 240 253 221/6 33% 41 11
Total room load 1344 1014 24 46
Air required(dm) 61 47 1 2
Caiculadons approved byACCAto meet all requirements of Manual J 8th Ed.
-f}t- wrYgtitsoTt 2022-Apr-1816:58:15
s GP. '^ Right Sute®Universal 2021 21.0.07 RSU24015 Page 3
erstone2508CRGRILot38BIIQWate 'rie'2508CRGRrtp Catc=W8 Horsefaces:NW
- - ht-J®Worksheet Job: Lot 38 Block 2 Waterstone 25
wrightsofr Rig ...
Entire House Date: NOVEMBER 3,2010
By. DCS
Del-Air Heating $Air Conditioning
531 Codisco Way,Sariord,FL 32771 Phorw 407-333-2665 Fax 407-333-3853 Web:wwadelair.com License:CAC05147
1 Room name LMNG RM FAMLY RMrFOYER
2 Etposedwall i 31.5 ft 25.0 ft
3 Room height 8.0 It heat/ocol 10.0 ft heaU000l
4 Room dimensions 14.0 x 13.5 ft 1.0 x 569.0 ft
5 Room area 189.0 iP 569.0 ft2
Ty Construction U-value' Or HTM Area OF) Load Area (ft-) Load
number (BtuhlfF-iF) (Btu hflP) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 1613-19ad - 0.049 ne 1.42 2.59 0 0 0 0 20 20 28 '52
vWW� Blk wall,stump eA 0201 ne 5.83 4.98 108 92 535 458 0 0 0 0
2A-2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
2A-2ov 0.280 ne 8.12 16.38 16 0 131 265 0 0 0 0
11 11J0 0.600 ne 17.40 17.58 0 0 0 0 0 0 0 0
V�! Blk wall,steam ext 0201 e 5 83 428 0 0 0 0 0 0 0 0
I-C 2A-2ov 0.22 a 8.12 7.60 0 0 0 0 0 0 0 '!,0
W 16B 19ad 0.049 se 1.42 2.59 0 0 0 0 20 20 28 52
Blkwall,stucco 6.4 0201 se 5.83 4.98 0 0 0 0 180 132 •, 771 659
.34 10C-v 0 �0 se 9.86 5.97 • 0 '0 .01 0 18 18 175 106
2A-2ov 0 280 se. 8.12 7.60 0 0 0 0 0 0 0 0
2A-2ov 0260 se 8.12 7.60 0 0 .0 0 30 30 244 228
2A-2ov 0280 se 8.12 14A 0 0 0 0 0 0 0 0
W 1613-19ad 0.649 sw 1.42 2.59 0 0 0 0 20 20 28 52
Blk wall,slucoo ext 0201 sw 5.83• 4.98 32 32 187 159 0 0 0 0
10C-v 6.340 sw 9.86 5.97 0 0 0 0 0 0 0 0
2A-2ov 0280 sw 8.12 14.46 0 0 0 0 0 0 0 10
W 16B-19ad 0.049 nw 1.42 2.59 0 0 0 0 20 20 28 152
131k Hell,sluoco era 0201 rW 5.83 4.98 112 80 464 397 70 29 170 145
2A-2ov 0280 nw 8.12 1529 32 0 263 495 - 0 0 0 0
2A-2ov 0280 nw 8.12 15A '0 0 0 0 0 0 0 11 0
2B-2fv 0290 nw 8.41 18.85 0 0 0 .0 8 0 63 141
213-21`v 0290 nw 8.41 15.99 0 0 0 0 13 0 112 213
2B-2fv 0.340 nw 9.86 17.31 0 0 0 0 0 0 0 0
11JO 0.600 nw 17.40 17.58 0 0 0 _ 0 20 20 ' 348 W2
P 12C-0ss 0.091 - 2.64 1.31 0 0 0 0 0 0 0 0
11DO 0.390 n 11.31 11.43 0 0 0 0 0 0 0 { 0
C 16830ad 0.032 0.93 1.69 189 189 175 319 569 569 528 961
F 22A-tpl 0.969 28.68 0.00 189 32 903 0 569 25 717 0
6 c)AED exeusion 122 -102
Envelope lossigain 2659 2216 3242 2911
12 a) Infiltration j 521 138 682 181
b) Room ventilation 0 01 0 10
13 Internal gains OoarpAnts @ 230 1 230 2 460
Applianoesidher 0 600
Subtotal(lines 6 to 13) 3180 2584 3924 4152
Less extemalload 0 0 0 10
Less transfer 0 0 0 ! 0
Redistribution 0 0 0 ; 0
14 Subtotal 3180 2584 3924 4152
15 Duct loads 221/6 33% 691 860 22% 33% 853 1382
Total room load 3871 3444 4777 5535
Air required(dm) 175 159 215 256
f
Calculations approved byACCAto meet all requirements of Manual J 8#1 Ed.
-�- wrigF.tsotFt �i 2022-Apr-1816:58:15
AC_�P. Right SrlteO Uriversal 2021 21.0.07 RSU24015 Page 4
ersbne2508CRGR1Lot38BIIQWatersto:ne2508CRGR.np Calc=MJ8 Horsefaces:NW
j
Job: Lot 38 Block 2 Waterston 25...
-wrightsoft, Rig hW@ Worksheet Date: NOVEMBER 3,2010
Entire House By. DCs
Del-A, Heating &Air Conditioning
531 Codisco Way,Sarthrd,FL 32771 Phone:407-333;2665 Fax 407-333-3853 Web:wwwdelair.com Liceree:CAC05147
1 Room name DINING RM BRI¢ST
2 Exposed wall 18.0 it 8.9 ft
3 Room height 10.0 it heat/cool 10.0 it heat/c001
4 Room dimensions • 13.5 x 14.5 ft 1.0 x 91.6 ft
5 Room area 195.8 ftz 91.6 T
Ty Construction U-value Or HTM Area (tF) Load Area (T) Load
number (Btuh/ft (BtuhtF) or perimeter (ft) (Btuh) or perimeter (ft) (Bluh)
Heat I Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool
6 W 168-19ad 0.0'49 ne 1.42 2.59 0 0 0 _ 0 _ 0 0 0 0
Blk wall,stuccoext 020,1 ne 5.83 4.98 10 10 58 50 0 0 0 0
2A-2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
2A-2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
11 11,10 0.600 ne 17.40 17.58 0 0 0 0 0 0 0 0
yJ Blk wall,iM000 e d 0201 a -1.83 -4.98 0 0 -0. 0 49 37 216 184
G 2A 2ov 0280 a 8.12 7.60 0 0 0 0 13 -- 13 .101 95
W 16B-19ad 0.049 se 1.42 2.59 0 0 0 0 0 0 0 0
Blk wall,stuoope)d 0201 se 5.83 4.98 0 0 0 0 46 •'26 160 137,
10C-v 0.340 se 9.86 5.97 0 0 0 0 0 0 0 1 0
2A-2ov 0280 se 8.12 7.60 6 0 0 0 13 13 101 95
2A-2ov 0260 se 8.12 7.60 0 0 0 0 -0 0 0 0
2A 2ov 0280 se 8.12 14.96 0 0 _0 0 0 0 0 0
W 168-19ad 0.049 sw 1.42 2.59 0 0 0 0 0 0 _ 0 0
Blk vwll,stucco wd 0201 sw 5.83 4.98 0 0 0 0 0 0 . 0 0
10C-v 0 340 sw 9.86 5.97 0 0 0 0 0 .0 0 0
2A-2ov 0280 sw 8.12 14.46 0 0 0 0 0 0 - 0 0
1N 168-19ad 0.049 nw 1.42 2.59 0 0 0 0 0 0 0 1 0
Blk wolf,stucco e)d 0201 nw 5.83 4.98 115 70 '411 351 0 0 0 j 0
2A 2ov 0280 nw 8.12 " '1529 0 0 0 0 0 0 0 0
2A-2ov 0280 nw 8.12 1529 39 0 313 589 0 0 0 0
213-2fv 0290 nw 8.41 18.85 0 0 0 0 0 0 0 0
2B-2fv 0290 nw 8A1 15.99 0 0 0 0 0 0 0 0
213-2fv 0340 nw 9.86 17.31 6 0 59 104 0 0 0 0
11JO 0.'600 nw 17AO 17.58 0 0 0 0 0 0 0 0
PII - 12C-0sw 0.091 - 2.64 1.31 55 55 145 72 0 0 0 0
L-D 11DO 0:390 n 11.31 11.43 0 0 0 0 0 0 0 0
0 16B30ad 0.'032 - 0.93 1.69 196 196 182 331 92 92 85 55
F 22A-tpl 0.989 - 28.68 0.00 196 18 516 0 92 9 256 0
I
6 c)AED exausion 297 -26
Envelope loss/gain 1684 1793 920 641
12 a) Infiltration i 258 69 185 49
b) Room ventilation ••, 0 0 0 0-
1311 Internal gains OcarpanL @ 230 1 230 0 0
ApplianoWother 0 0
Subtotal(lines6to13) 1942 2092 1105 690
Less exlemal load 0 0 0 0
Lesstransfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1942 2092 1105 690
15 Ductloads 22% 33% 422 696 221/6 33% 240 230
Total room load 2365 2788 1345 920
Airrequired(dm) 107 1291 61 :42
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-FW wrG0t-.-j Ft� F 2022-Apr-1816:58:15
.-�A Right S te@ Uriversal 2021 21.0.07 RSU24015 Page 6
erstone2508CRGRVot38BII2Waterst0re2508CRGRnp CaIc=MJB Hcusefaces:NW
wrightsoft Ri ht-J®Worksheet Job: Lot 38 Block 2 Waterst'one 25...
En i 1 House Date: NOVEMBER 3,2010
By. DCS
Del-Ai'r Heating $Air Conditioning
531 Codisco Way,Sanford,FL 32771 Phone:407-333165 Fax 407-333-3853 Web:wwwdelair.com License:CAC05147
1 Room name IQTCHEN UTILITY
2 E)posed wall 0 It 10.5 ft
3 Room height 10.0 ft heat/cool 8.0 ft heattmol
4 Room dimensions 13.0 x 12.0 It 7.5 x 16.0 It
5 Room area 156.0 ft 120.0 fF
Ty Construction U-value,' I Or HTM Area (ft=) Load Area OF) Load
number (Btuhflt;°F) (BtuhR2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
�I Heat I Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool !
i
6 W 16819ad 0.049 ne 1.42 2 59 0 0 0 0 0 6 _ 0 0
VL� Bilk wall,stucco eQ 020,1 ne 5.83 4.98 0 0 0 0 0 0 0 0
2A-2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
2A-2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
11 1111,10 0.600 ne 17.40 17.58 0 0 0 0 0 0 0 0
Blk wall,sluoco e�Q 020�1 a 5.83 4.98 0 0 0 0 0 0 0 6
I . G 2A 2ov 0280 a 8.12 7.60 0 0 0 0 0 0 0 .-, 0
W 1613-19ad 0.049 se 1.42 2.59 0 0 0 0 0 0 0 0
Blk wall,stu000 eA 0291 se 5.83 4.98 0 0 0 0 0 0 0 0
10C-v " 0.340 se 9.86 5.97 0 0 0 0 0 0 0 0
2A 2ov 0280 se 8.12 7.60 0 0 0 0 0 0 0 0
2A 2ov 0260 se 8.12 7.60 0 0 0 0 0 0 0 0
2A-2ov 0280 se 8.12 14.96 0 0 0 0 0 0 0 0
W 16B-19ad 0.049 sw 1.42 2.59 0 0 0 0 0 0 0 0
Blk well,stucco ext. 0201 sw 5.83 4.98 0 0 0 0 0 "0 0 0
IOC-v 0.340 sw 9.86 5.97 0 0 0 0 0 0 0 0
2/,-2ov.. 0280 sw 8.12 14.46 0 _ 0 0 0 0- 0 0 0
w 1613-19ad 0.049 nw 1.42 2.59 0 0 0 0 0 0 _ 0 10
Bik wall,stuccoo ext 02U1 nw 5.8-3 4.98 0 0 0 0 6 0 0 10
2A-2ov 0280 nw 8.12 1529 0 0 0 0 0 0 0 0
2A-2ov 0280 nw 8.12 1529 0 0 0 0 0 '0 0 0
213-2ry 0290 nw, 8AII 18.85 0 0 0 0 0 0 0 0
26-2fv 0290 nw' 8A1 15.99 0 0 0 0 0 0 0 0
213-2ry 0,340 nw 9.86 17.31 0 0 0 0 0 0 0 0,
11JO 0.600 nw 17.40 17.58 0 0 0 0 0 0 0 10
P11 -- 12C-0sw 0,001 - 2.64 1.31 0 0 0 0 84 66 175 187
L-D 11DO 0.'360 n 11.31 11.43 0 0 0 0 _ 18 18 201 203
C- 161330ad 0.032 - 0.93 1.69 156 156 145 264 120 120 111 203
F 22A-tpl Ob'9 - 28.68 0.00 156 0 0 0 120 11 301 1 0
' I
-
i
i
6. c)AED exarsion ;, 52 I39
Envelope loss/gain 145 211 788 454
12' a) Infiltration 0 0 0 10
b) Room ventilation 0 0 0 0
13 Internal gains: Oootpal @ 230 0 0 0 10
Applianoes/other 1200 600
Subtotal(lines 6 to 13) 145 1411 788 1054
Less wdemalload 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 145 1411 788 1054
15 Dudloads 221/6 33% 31 470 22% 33% 171 351
Total room load 176 1881i . ........I--
960 1404
Airrequired(dm) 8 87 43 165
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
_ ` wrightsoft^ ! I 2022-Apr-1816:58:15
Fiigtt Sute®Uriversal2021 21.0.07 RSU24015
'MCA ...ersbre2508CRGR1Lot38BIIQWaterstcne2508CRGRnp Calc=W8 Horaefaces:NW Page6
i
I ! I
i
- -Wrightsoft' Right-J®Worksheet Job: Lot 38 2 Waterstone 25...
Entire House Date: NOVEMBER ER 3,2010
By. DCS
Del-Air Heating &Air Conditioning
i
531 Codisco Way,Sanford,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:wwwdelair.com License:CAC05147
1 Room name BATH 2 BDRM2
2 Exposed wall 5.5 ft 30.5 ft
3 Room height I' 8.0 ft heat/cool 8.0 ft heatlwoI
4 Room dimensions 5.5 x 13.0 ft 11.5 x 16.0 ft
5 Room area 71.5 T 184.0 il=
Ty Construclion U-value, Or HTM Area (w) Load Area (ft-) Load
number (BtuhlftL°F�f or perimeter (ft) (Bhih) I or perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cod Gross NIP/S Heat Cool
6 W " 168,19ad 0.049 ne 1.42 2.59 6 0 '0 0 0 0 0 0
Blk wall,sfli000 ext 0201 ne 5.83 4.98 0 0 0 0 0 0 0 0
2A-2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
2A-2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 '0
11 11JO 0.600 ne 17.40 17.58 0 0 0 0 0 0 0 0
1N Blk mall,stucco ext 0201 a 5.83 4.98 0 0 0 0 6 0 0 0
L-G 2A 2ov 0280 a 8.12 7.60 0 0 0 0 0 0. 0 ;0
W 16B-19ad 0.049 se 142 2.59 0 0 0 0 0 0 0 0
Blk wall,stucoD ext 0201 se- 5.83 , 4.08 '0 0 0 0 0 0 0 ,0
10C-v 0.340 se 9.86 5.97 0 0 0 0 0 0 0 0
2A=2ov 0280 se 8.12 7.60 0 0 0 0 0 0 0 0
2A 2ov 0280 se 8.12 7.60 0 0 0 0 0 0 0 0
2A 2ov 0280 se 8.12 14.96 0 - 0 0 0 0 0 0 1 0
W 16B-19ad 0.649 sw 1.42 2.59 0 0 0 0 0 0 0 0
Blk wall,stucco ext 04,1 sw 5.83 4.98 0 0 0 0 128 112 652 557
10C-v 0.340 sw 9.86 5.97 0 0 0 0 0 0 0 ! 0
��-----GGG 2A-2ov. 0280 sw. _ 8.12 14A6 0 0 0 0 16 4 131 _". 234
W 16B-19ad 0.049 nw 1.42 2.59 0 0 0 0 0 0 0 0
Bik wall,stucco ext 0" 1 nw 5.63 4.98 0 " 0 0 0 0 0 0 0
2A 2ov 0280 nw 8.12 1529 0 0 0 0 0 0 0 10
2A-2ov 0280 nw 8.12 1529 0 - 0 '0 0 0 0 0 ? 0
2B•2fv 0290 nw 8.41 18.85 0 0 0 0 0 0 0 0
2B-2fv 0290 nw 841 15.99 0 0 0 0 0 0 0 0
2B-21v 0.340 nw 9.86 17.31 0 0 0 0 0 0 0 j 6
11,10 0.6(0 nw 17AO '17.58 0 0 0 0 . . 0 0 0 0
PI - 12C-Osw 0.091 - 2.64 1.31 44 44 116 58 116 116 306 152
D_ 11D0 0.390 n 11.31 11.43 0 0 0 0 0 0 0 j 0
IC 16B-30ad OA32 - 0.93 1.69 72 72 66 121 164 184 171 311
F 22A-tpl 0.969 - 28.68 0.00 72 6 158 0 184- 31 875 f 0
I,
u
6 c)AED excursion -6 160
Envelope loss/gain �' 340 172 2135 1314
12 a) Infiltration i, 0 0 265 70
b) Room ventilation 0 0 0 10
13 Internal gains: Occupants @ 230 0 0 0 10
Appliahoestother 0 300
Subtotal(lines 6 to 13) 340 172 2399 1684
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 340 172 2399 1684
15 Duct loads 22% 33% 74 57 22% 33% 522 561
Total room load 414 229 2921 2245
Air required(dm) 19 11 132 104
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
_ - wrigF�tsoft- I I 2022-Apr-1 8 16:68:15
Right Sute®Uriversal 2021 21.0.07 RSU24015 Page 7
erstone2508CRGRIot38BIIQWaterst6re2508CRGRrnp Calc=MJ8 Hoisefaces:NW
w htsoft= Ri ht-.1®Worksheet Date: NOVEMBER 3,2010
Job: Lot 38 Block 2 Waterston 25
ri ...
9 En ire House
I. J By. DCS
Del-Air Heating &Air Conditioning
531 Codisco Way,Sardord,FL 32771 Phore:407-333-I665 Fax 407-333-3853 Web:ww&delair.com License:CAC05147
1 Room name BDRM3 BDRM4
2 Exposed wall b 14.0 ft 25.5 ft
3 Room height 8.0 ft heat/000l 8.0 ft heatl000l
4 Room dimensions 11.5 x 14.0 ft 11.5 x 14.0 ft {
5 Room area 161.0 ft 161.0 ft= II
Ty Construdion U-value Or HTM Area (ft2) Load Area (W) Load 1
number (BtuhlfF°,F) (Btuhlll=) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) !
I
Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cod
u.it
6 ;W 1613-19ad - 0.049 ne 1.42 2.59 0 0 0 0 0 _ 6 6 0
BIk wall,stu000 ext 0201 ne 5.83 4.98 0 0 0 0 0 0 0 0
2A 2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
2A 2ov 0280 ne 8.12 16.38 0 0 0 0 0 0 0 0
11 11J0 0.600 ne 17.40 1.7-f@ 0 0 0 0 0 0 0 0
tBlkvdl,stuoob,ext 0201 a 6.93 ' 4.98 0 0 6 0 0 0 0 0
-.G 2A-2ov 0280 a 8.12 7.60 0' 0 0 _ _ 0 0 -0 0 .,..0
W 1613-19ad 0.049 se 1.42 2.59 0 0 0 0 _ 0 0 0 0
elk wall stuo�o ext: 0201 se 5 83 '4.98 0 0 0 0 92 76 442 378
10C-v 0.340 se 986 5.97 . 0 0 _0 0 0 0 0 0
2A 2ov 0280 se' 8.12 7.60 0 0 0 0 0 0 -6 0
2A 2ov 000 se 8.12. 7.60 0 0 0 0 0 0 0 0
2A-2ov 0280 se 8.12 .14.96 0 0 0 0 16 3 131 242
W 16B-19ad OA49 sw 1.42 2.59 0 0 0 0 0 0 0 0
BIk wall,shiaco ext' 0201 sw 5.83 4.98 112 96 558 477 112 112 653 558
10C-d ONO sw 9.86 5.97 0 0 0 0 0 ,0 0 0
2A-2ov 0 280 sw _8.12 14.46 16 4 131_ 234 0 0 0 0
W 16B-19ad 0.049 nw 1.42 259 0 0 0 0 0 0 0 0
Blk wadl,stu=o e)d 0201 r w 5.83 4.98 0 6 6 0 0 0 6 0
2A-2ov, 0280 nw 8.12 1529 0 0 -0 0 0 0 . 0 0
2A-2ov ONO nw 8.12 15.29 0 0 0 0 0 0 0 0
2132fv 0290 nw� 8.41 18.85 0 0 0 0 0 0 0 0
213-21v 0 290 nw 841 15.99 . 0 0 0 0 0 0 0 0
2B-2fv 0* nw 9,96 '17.31 0 0 0 0 0 0 0 0
11JO 0:600 nw 17.40` 17.58 0 0 0 0 0 0,. 0 0
PI _ 12C-Osw 0.091 - 2.64 1.31 0 0 0 0 0 0 0 0
�-D 11D0 O.390 n 11.31 11.43 0 0 - , ,. 0 0 0 _ 0 0 110
C' 161330ad 0.'032 - 6.93 ` 1.69 161 161 149 272 161 '161 149 272
F 22A tpd 0.'* - 28.68 0.00 161 14 402 0 161 26 731 0
6 c)AED excursion I 70 184
Envelope loss(gain 1241 1053 2107 1534
12 a) Infiltration 231 61 422 112
b) Room ventilation 0 0 0 0
13, Internal gains: Oocupants @ 230 0 0 0 10
Appldances/other 300 300
Subtotal(1ines 6 to 13) 1472 1415 2529 1946
Less external load 0 0 0 10
Lesslransfer 0 0 0 0
Redisldbution 0 0 0 0
14 Subtotal 1472 1415 2529 1946
15 Dudloads ! 22% 33% 320 471 22% 33% 550 6Q
Total room load 1792 1886 3078 2594
Air required(cfm) 81 87 139 120
i
'I
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
f* w.-!Iw soft- ! 2022-Apr-1816:68:15
RigaSutew Universal 2021 21.0.07 RSU24015 Page 8
erstore2508CRGRLot38BIIQWaterstri 2508CRGRn{p Calc=W8 Horsefaces:NW
r ,
*'wrightsofr RighW@ Worksheet Job: Lot 38 Block 2 Waterstone 25...
EntfT House Date: NOVEMBER 3,2010
By. DCS
Del-Air Heating &Air Conditioning
531 Codisoo Way,Sarthrd,FL 32771 Phone:407-333I-2665 Fax 407-333-3853 Web:wwwdelair.cem License:CAC05147
•I
1 Room name BATH 3 j
2 F)Vosedwall 'i 13.5 It
3 Room height 8.0 ft heat/000l
4 Room dimensions 1.0 x 109.0 It
5 Room area 109.0 fF
Ty Construction U-value :j Or HTM Area (T) Load Area Load
number (BtuhAF) or perimeter (ft) (Btuh) or perimeter I
ICI
Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cod
6 I W 1613-19ad 0.049 ne 142 2.59 0 0 0 0
Bik wall,stuom ext 0201 ne 5.83 4.98 44 28 165 141
2A-2ov 0280 ne 8.12 16.38 0 0 0 0
2A 2ov 0280 ne 8.12 16.38 0 0 0 0
11 11.10 0.600 ne 17.40 17.58 16 16 272 275
Blk wall shuoco ext 0201 a 5.83 4.98 0 0 0 0
2A-2ov 0280 a 8.12 . 760 0 0 0 0,
W 1613-19ad 0049 se 1.42 2.59 0 0 0 0
VNBlk wall,stucco wd 0201 se 5.83 ,4.98 64 64 373 319
10C-v 0:340 se 9 86 . 5.97 0 0 0 0 {
2A 2ov 0280 se 8.12 7.66 0 0 0 0 !
2A 2ov 0280 se 8.12 7.60 0 0 0 0 I
2A-2ov 0.280 se 8.12: 14.96 0 0 0 0
W 16B-19ad 0.049 sw 1A2 2.59 0 0 0 0
Blk well,shicoo ext 0201 sw 5.83 4.98 0 0 0 0 -
VJ�J-C 10C-v O:140 sw 9.86 527 0 0 0 0
�G 2F,2ov - 0280 sw. 8.12 - 14.46 0 0 0 0
W 16B-19ad Og9 nw 1.42 2.59 0 0 0 0
Blk wall,stu000 ext 0201 nw '6'A3 4.98 0 0 0 = 0
2A2ov 0280 nw ,•8.12 1529 0 0 0 0
2A-2ov ' . 0 nw 8.12 1529, 0 0 0 0 280
2B-2fv 0290 nw 841 18.85 0 0 0 ' $
2B-2fv 0" nw Al 15.99 0 0 0 0
290 8 1
2B-2fv' 9,86 17.31 6 0 0 0 0:340 nvir
I,
11 .40 17. 0 -0" ` 0 � `0
JO ,0.600 nw � 17 58
P 12C-Osw 0:091 - 2.64 1.31 0 0 0 0
11DO 0'390 n 11.31 11.43 0 0 0 0
C 16R.30ad O'.032 - 0.93 1.69 109 109 101 184
F 22A-tpl obi§9 - 28.68 0.00 109 14 387 0
{
_
P' S
I
6 c AED ewrsusion -35
Fwelo I pe osslgain � �I 1299 884
12, a) Infiltration i; 223 59
b) Room ventilation 0 0
r, d
13 Internal gains: Occupants @ 230 0 0
Applia igos(other 0
Subtotal Oines6to13) y ' 1522 944
Less exbemalload 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 1522 944
15 Dud loads 22% 33% 331 314
Total room load 1853 1258
Air required(dm) 841 58
i
Calcu6tons approved byACCAto meet all requirements of Manual J 8th Ed.
_01- wriightsoTt R ;1 2022-Apr-1 8 16:58:15
Riglt SUte®Universal 2021 21.0.07 RSU24015 Page 9
erstone2508CRGR1Lot38BIIQWaterstone2508CRGRrtQ Calc=MJ8 Horsefaces:NW
I '
i
Job: Lot 38 Block 2 Waterston...
wrightsoft® Duct System Summary Date: NOVEMBER 3,2010 1
Entire House By. DCS
Del-Air Heating&Air Conditioning
I
531 Codisco Way,Sarthrd,FL 32771 Phore:407-333L2665 Fax 407-333-3853 Web:wmdelairxom License:CAC05147
li 'I
Project Information
For. Adams Homes
8521 Waterstone Boulevard,Fort Pierce,FL34951
Heating Cooling
External static pressure ;' OAO in H2O OAO in H2O i
Pressure losses ' 0.06 in H2O 0.06 in H2O j
Available static pressure j, 0.34 in H2O 0.34 in H2O
Supply/return available pressure 0.170/0.170 in H2O 0.170/0.170 in H2O
Lowest friction rate 0.230 in/100ft 0.230 in/100ft
Actual airflow 1400 cfm 1400 cfm
Total effective length(TEL) 148 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) f (cfm) (d rn) FIR (in) (in) Mal Ln(ft) Ln(ft) Trunk
BATH 2 h 414 ' 19 11 0.445 4.0 Ox 0 VIFx 6A 70.0
B41-13 h 1853 84 58 0.313 6.0 Ox 0 MFx 23.8 85.0 st1
BDRM2 h 2921 132 104 0.410 6.0 Ox0 VIFx 13.0 70.0
BDRM3 c 1886 81 87 0.396 6.0 Ox0 VIFx 15.8 70.0 1
BDiaMa h 3078 139 120 0.305 7.0 Ox0 VIFx 26.3 85.0 st1
BRKFST h 1345 61 42 0.312 6.0 Ox0 VIFx 23.8 85.0 st1
DINING RM c 2788 107 129 0.399 7.0 Ox 0 VI Fx 15.1 70.0
FAMILYRWOYER c 2767 108 128 0.312 7.0 Ox0 VIFx 24.1 85.0 st2
FAMILYRWOYER-A c 2767 108 128 0.312 7.0 Ox0 VIFx 24.0 85.0 st2
KITCHEN c 1881 8 87 OA36 6.0 Ox 0 VIFx 8.0 70.0
LNING RM h 3871 175 159 0.276 8.0 Ox 0 VIFx 38.2 85.0 st2
M.Wic c 46 1 2 0.245 4.0 Ox 0 VIFx 38.6 100.0 st3
KWIC h 1018 46 28 0.247 4.0 Ox 0 VIFx 37.6 100.0 st3
M.wlc II c 129 3 6 0.253 4.0 Ox 0 MR 34.5 100.0 st3
MASTER BATH h 1344 61 47 0.249 5.0 Ox 0 VI Fx 36.4 100.0 st3
MASTERBDRIN h 5047 228 199 0.230 8.0 Ox0 VIFx 47.5 100.0 st3
UTILITY c 1404 43 1 65 1 OA57 1 5.0 Ox0 1 VIFx 4.5 70.0
I
SupplyDetail Table
� 'I I
Trunk Htgl , Clg Design Veloc Diam H x W Duct
Name Type (cim); (cfrn) FIR Opm) (in) (in) Material Trunkl
st3 PeakAVF 338 282 0.230 .620 10.0 0 x 0 VinlFlx st2
st2. PeakAVF 728 697 0.230 521 16.0 0 x 0 VinlFlx
SO PeakAVF 283 220 0.305 641 9.0 0 x 0 VinlFlx
I
-F�- wrightsoft® 2022-Apr-1816:58:17
RigftStiteGUriversal202l2l.O.O7RSU24015
g ;1 Page 1
ACCA ...ersbne2508CRGR1Lot38BIIQWate 2508CRGRnp Calc=MJ8 Harsefaces:NW
, I
Return Branch Detail Table
Grille Htg ClgI
TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) Cfrn n) (ft) FR (fpm) (in) (in) Opening(in) Mal Trunk
rbl Ox 0 1400 -:1400 0 0 0 0 Ox 0 \A Fx
-Fk- wrightsoft- 2022-Apr-1816:58:17
-1-1-6. Right-SUte@ Uiversal 202121.0.07 RSU2401 5
ACCK ersbne26O8CRGR\L.t38Blk2Watersto" I Pa .2
ne2508CRGF;LW Calc=W8 Housefaces:NW
Ig
it
Florida Building Code, Energy Conservation, 7th Edition (2020)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 8521 Waterstone Boulevard Permit Number:
I.Fort Pierce, FL,34951
MANDATORY REQUIREMENTS -See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level'(EPL)display card(Mandatory)The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law:
(Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The!EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the'plans
and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD.
LI
SECTION R402 BUILDING THERMAL ENVELOPE
' I
❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
i
❑ R402.4.1 Building thermal envelopeThe building thermal envelope shall comply with Sections R402.4.1.1 and
R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
❑ R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required
by the code official,an approved third party shall inspect all components and verify compliance.
I ,
❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zo I es 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either
individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or
an approved third party.A writtein report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building,thermal envelope of existing
buildings in which the new con'siruction is less than 85 percent of the building thermal envelope.
I
During testing:
1.Exterior windows and doors;f replace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures.
2.Dampers including exhausti.intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures. �I
3.Interior doors,if installed at the time of the test,shall be open.
4.Exterior doors for continuouls''ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems if installed at the time of the test,shall be turned off.
6.Supply and return registers 1 if installed at the time of the test,shall be fully open.
❑ R402.4.2 Fireplaces. New wood-bIurning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where
using tight-fitting doors on factory-built,fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the
'fireplace.Where using tight-fitting doo�s on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
! I
❑ R402.4.3 Fenestration air leakage Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built wind ws,skylights and doors.
I {
I I
i
4/18/2022 4:55 PM EnergyGa ge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 5
' I
MANDATORY REQUIREMENTS - (Continued)
R402.4.4 Rooms containing fuel-burn Ing appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to
open combustion fuel burning appliances,1 the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room,isolated from inside!ti a thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated w iere it
passes through conditioned space to a minimum of R-B.
Exceptions: a
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential.
R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditionedi spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasketior caulk between the housing and the interior wall or ceiling covering.
i
SECTION R403 SYSTEMS
11403.1 Controls.
R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing(Mandatory) III ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall Ibe considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial0rovisions of this code and shall be shown to meet duct tightness criteria below. J
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or
(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(0,(g)or(1),Florida Statutes,to be"substantially leak free"in
accordance with Section R403.3.3.
❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing(Mand`ati ry).Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,
including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise
sealed during the,test. 1
2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire
system,including,the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test.
r,
Exceptions:
1. A duct air leiakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
I 2. Duct testing,',ii not mandatory for buildings complying by Section 405 of this code.Duct leakage testing is required for Section
R405 compliance where credit is taken for leakage,and a duct air leakage Qn to the outside of less than 0.080(where Qn=
duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals)is indicated in the
compliance Ire port for the proposed design.
11
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑R403.4 Mechanical system piping insullation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulated;to a minimum of R-3.
❑ R403.4.1 Protection of piping iinsulation. Piping insulation exposed to weather shall be protected from damage,including that
caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause
degradation of the material.Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). If heated water circulation systems are
installed,they shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with
Section R403.5.1.2.Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall
❑ be a dedicated return pipe oor a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited.Controls for
circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The
controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no
demand for hot water. j
R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall
automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the
times when heated water is used in the occupancy.
4/18/2022 4:55 PM EnergyGia ge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 2 of�5
r
MANDATORY REQUIREMENTS - (Continued)
❑ R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least '/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies(Mandatory).
❑ R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature
setting range shall be from 1.00°F to 140°F(38°C to 60°C).
I ,
❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of
combustion types of service water-heating systems to be turned off.
❑ R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 o I the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provided)bating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
❑ R403.5.6.2.1 Solar water" heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC StandardlTM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar
water-heating systems should meet the following criteria: J
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at'an orientation within 45 degrees of true south.
I
❑ R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential;)or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation
including:Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
❑ R403.6.1 Whole-house mechanical ventilation system fan efficacy.When installed to function as a whole-house mechanical
ventilation system,fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole-house mechanical
ventilation,the air handler shall be powered by an electronically commutated motor.
ElR403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable
Indoor Air Quality,shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10
otherwise.
R403.7 Heating and cooling equipment.
R403.7.1 Equipment sizingl,(Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based
❑ ; on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation
methodologies,based on building loads for the directional orientation of the building.The manufacturer and model number of the
outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design
conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other
factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical
ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have
an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is
installed. TABLE R403.6.1
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMU I
(CFM) (CFMN1/ATT) (CFM)
HRV or ERV i, Any 1.2 cfm/watt Any
Range hoods Any 2.8 cfm/watt Any
In-line fan Any 2.8 cfm/watt Any
Bathroom,utility room 10 1.4 cfm/watt <90
I
Bathroom,utility room 90 2.8 cfm/watt Any
I
I '
For SI: 1 cfm=28.3 Umin. a. When tested in accordance with HVI Standard 916
4/18/2022 4:55 PM EnergyGa l ge0 USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of I5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section R403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's
expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb
11
temperature for the load calculation(or.entering water temperature for water-source equipment),the blower CFM provided by the expanded
performance data,the design value for,enteringwet-bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet-bulb anal dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for r,`eturn side gains if the return duct(s)is installed in an unconditioned space.
Exceptions: ?
1. Attached single and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and Pealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of
equipment may be!;szed in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section i
R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.1,5 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
Ij .
❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric bumers
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
it
R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
ElC403 and C404 of the Florida Building Code,Energy Conservation—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system icontrols(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C).
❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
The electric power to heaters shall be controlled by a readily accessible on-off switch that is an
❑ R403.10.1 Heaters. 1
integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation
of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the
power to the heater.Gas-fred heaters shall not be equipped with continuously burning ignition pilots.
❑ R403.10.2 Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule
j shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this
section. i' 1
Exceptions:
1. Where public health IisLndards require 24-hour pump operation.
2. Pumps that operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
I
it
4/18/2022 4:55 PM EnergyGauge@ USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 4 of 5
' I I
R403.10.3 Covers. Outdoor heated'siwimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at
❑ ;the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered
energy,such as from)a heat pump or solar energy source,covers or other vapor-retardant means shall not be required.
R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal
❑ efficiency of 82 percent for heaters'Imanufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool
heaters fired by natural or LP gas,1 all not have continuously burning pilot lights.
❑ R403.10.5 Heat pump pool heaters., Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
With AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
❑ R403.11 Portable spas(Mandatory),.The energy consumption of electric-powered portable spas shall be controlled by the
requirements of APSP-14. '
❑ R403.13 Dehumidifiers(Mandatoryl If installed,a dehumidifier shall conform to the following requirements:efficiency1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/kWh if the total dehumidifier capacity for the house
is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day.
2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air.
3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2.
4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code,Residential.
� I
❑ R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13,
conform to the following requirements:
1. If a ducted dehumidifier's configured with return and supply ducts both connected into the supply side of the cooling system,a backdraft
damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct.
2. If a ducted dehumidifies•is configured with only its supply duct connected into the supply side of the central heating and cooling system,
a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct.
3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the
central cooling evaporator coil.! j
4. Ductwork associated W`iiL a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6.
SECTION R404
I
ELECTRICAL POWER AND; LIGHTING SYSTEMS
❑ R404.1 Lighting equipment(Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an
efficacy of at least 45 lumens-per-watt'or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt.
I
R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
j,
I
i
r
i'
P
f
I'
i
i
I
i
i
4/18/2022 4:55 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of;5
, I
' I
FORM R405-2020
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
J' J
Florida!Department.of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the
Residential Simulated Performance Alternative shall include:
❑ This checklist
❑ Form R405-2020 report
❑ Input summary checklist that can be used for field verification(usually four pages/maybe greater)
I
❑ Energy Performance;Level(EPL) Display Card(one page)
;1
y ❑ HVAC system sizing!and selection based on ACCA Manual S or per exceptions provided in Section R403.7
❑ Mandatory Require," nts(five pages)
.11
Required prior to CO:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.9 -one page)
❑ A completed 2020 Envelope Leakage Test Report(usually one page);exception in R402.4
allows dwelling u'nits of R-2 Occupancies and multiple attached single family dwellings to
i
comply with Section C402.5
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
2020 Duct Leakage Test Report-Performance Method(usually one page)
j
p
I U
'r
;
I j
1i
4/18/2022 4:54:14 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 of 1
I
i
2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a
r
Project Name: Lot38Blk2WatersItone2508CRGR Builder Name: Adams Homes
Street: 8521 Waterstone,Boulevard Permit Office:
City,State,Zip: Fort Pierce,FL 184951 Permit Number: Y
Owner: Jurisdiction: 661000 I' I =
w
Design Location: FL,ST LUCIE CO INTL U
f
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints1;in the air barrier shall be sealed.
The air barrier in'any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings)drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of.the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a thermal resistance of R-3j
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
j walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/doorjambs and framing,and
and doors
skylights and framing shall be sealed.
Rim joists Rim joists shall,19clude the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed onl
the underside of floor framing and extends from the
+ bottom to the top of all perimeter floor framing
• members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor,,retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall .
Shafts,penetrations Duct shafts,utility, penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
l spaces.
an
Garage separation Air sealing shall be provided between the garage and conditioned spac 3s.
Recessed lighting Recessed lightifidures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed�to the finished surface. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space sljall
extend behin piping and wiring,
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on'exteriorwall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exteriorwalls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply add return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor,wall covering or
Concealed When required,to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a man i er that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a.In addition,inspection of log walls shallIbe in accordance with the provisions of[CC-400.
4/18/2022 4:55 PM EnergyGaluge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
!
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida! •Building Code, Energy Conservation, 7th Edition
Jurisdiction: 661000 Permit#:
Job lnfo'rmation
h
Builder: Adams Homes Community: Lot: 38/2
i �
Address: 8521 Waterstone Boulevard
City: Fort Pierce State: FL Zip: 34951
Air Leakage Test.Results Passing results must meet'either the Performance Prescriptive, or ERI'Method
0} PRESCRIPTIVE METHOD The building or dwelling unit stiall.be tested and verified as having an air leakage rate of not exceeding-7 air
changes per hour at a pressure of 0.2 inch w.g.(50,P.ascals)in Climate Zones 1 and 2.
,j
Q ''PERFORMANCE or,ERI METHOD The.building or dwelling unit shall be'tested and verified as having an air leakage rate of not exceeding
the selected ACH(50)value,as showm on Form 11405-2020(Performance)orR406-2020(ERI),section labeled as infiltration„sub-section ACH50.
f j.
ACH(50)speclltied on Form R465-2020-Energy,Calc(Performance)orR406-2020(ERI) 6.750
II II
{ x 60 = 9.047062E30 = Method for calculating building volume:
CFM(50) Building Volume ACH(50)
Q Retrieved from architectural plans
F-1 PASS, Code software calculated
,i
When ACH(50)is lessithan 3, Mechanical Ventilation installation Q Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing.Testing shall be'conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f),(g),or(i)or an approveId'Ithird party.A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing: it
1°.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration
control measures.
2.Dampers including exhaust,intake;'makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control
measures.
3.Interior doors,if installed at the timl of the test,shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems,if installed at the time of the test,shall be turned off.
(i.Supply and return registers,if Installed at the time of the test,shall be fully open.
I' 'I
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
,Signature of Tester: Date of Test:
Printed Name of Tester:
I
License/Certification#: Issuing Authority: j
I
4/18/2022 4:55:36 PM !EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 1 of 1
---- — --- i6D MPH ePF
-- --------- 5"
bath duct -- --�- -Q.._.--- ----- --- - ,wNrI
to roof cap
w/ standard 70
cfm both fan B n,
C.� t
O U ca J- c
U' SJ G LEc
I8LANAI VP ........... I,,l
BEDROOM 4 cs^-"^"'^_•^` N. 1.i t T K�
OWNER ClV C / �� 2� dv - -
O r � -1 1 ! ��b iwcd `
_ ,,..,,,t•;,'-+ `�v 10.6 iwcd 10x6�x� 7• 120
w< - - �> q
_..�._ �O 130EAIStAST�D (� ? 2 ra " � !
-
_ ---zoo--- hfixlfi-roq'*�- °.:- t-•-
II
T- 12x12 I g - --
rag A
_ I ,� Y —..... z10 rag
a8x4 twctl�� ffr .§ Ila !L. 1,0jx6
�. S d 3o 1 ,. I FAMILY ROOM qq10.61wcd!— 12360 iwcd 2306 lwcd lwctl 105 I'7° z � l
D° ®yfw�to 10 rag ! ! N (V N
fox.loved ( J ® ..x =•+m- N O
24z18(brag x ag B W -"1^'
�. I N
0
Uj
10 10 r
..<. B'S t 1 16 I/ b • BEDROy A7 2 a= Q N m
i r 7 S. a 00 lit
S.
IOz6 iwcd �
i,....] I INI NG 0 125
D fi -
°6 I t xo6 70
LlNSG1G.RD.2Ml I I`i '5 12 wca 0i6SC 11 d
,14v8 wad
140 - Q
_ Lin hxti
4 42"x42" A/C Slob
By Builder Min.
2 from Wall
4°dryer duct
to tool cop er].5 TON W/5xW 0240V 1PH O
m ,' w ^ PATRY ^ w/dryer vent box 1Bx13 Plen pldrlorrn by _Z CD
00
5" bath ductO
to roof cap nags+BacP I N
w/ standard 70 "� - —'a n, � �w
1 LLJ
cfm bath fan 1 ] l, _':_c b._.._. �._..__. N -
U
5" bath duct 5 bath duct W
to roof cap to roof cap � , ? C) m
w/ standard 70 w/ standard 70 © ,�� (1) U)
cfm both fan-light cfm bath fan '� ,> r,a I Q Om >
w O L0 10 13� O O
NOTE TO BUILDER:MUST PROVIDE UNRESTRICTED Q C,4 J d Z 0
1 INCH UNDERCUT BELOW DOORS TO HABITABLE ROOMS
Transfer ducts/grills sized in compliance p a}I EA CAL.CU(r--__
with Florida Residential Building Code-M1602.4 f
balanced return air.. - (D r�
EXCEPTIONS 1-3 FLOOR PLAN m
IF VAT "CR° n 7.,, v,�.,, W
_j Lul
I— m
Must hove a minimum clearance Of 4 inches around the air handier per the State Energy code. All duct nos an r 6 insulation value. ( ! co 0__ _j U 0 0