HomeMy WebLinkAboutEnergy Efficiency CodeR
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 184 Phase 3 Waterstone 1480 BGL
Builder Name: ADAMS HOMES
Street: 5318 Vespera Street
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�1443.6 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1207.80 ft2
b. Frame - Wood, Adjacent
R=13.0 235.83 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1484.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1484.00 ft2
6. Conditioned floor area above grade (ft2) 1484
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(190.5 sqft.) Description Area
12. Ducts
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 296.8
a. U-Factor: Dbl, U=0.33 143.22 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.55 17.78 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.70
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.30 16.19 ft2
SHGC: SHang
D1
Area Weighted Average Overhang Depth: 3.503 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.278
a. Electric Heat Pump
28.2 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1484.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1484.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 47.98
Glass/Floor Area: 0.128
PASS
Total Baseline Loads: 48.94
I hereby certify that the plans a p ations covered b
Revie .of the plans and
��ZIi�ST9T8
this calculation are in compli c the Florid rgy
specifications covered by this
_ p
Code.
calculation indicates compliance
c,�� rir,���''� ' =,�•``,•�+
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 117-21-2091 Winn Kenmany
this building will be inspected for
VI'�
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
1. Al
with the Florida Ener Code.
Cop
OWNER/69EN
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
r
7/21/2021 9:39 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Pagel of 4
FORM R405-2020 INPUT SUMMARY CI-IFCKI IST RFPnRT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 184 Phase 3 Waterstone Bedrooms: 3
User Conditioned Area: 1484
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Street Address
Lot # 184 Phase3
Block/Subdivision: Waterstone
PlatBook:
Street: 5318 Vespera Street
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
/
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1484 13356
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1484 13356 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 150.8 ft 0
1484 ft2 ---- 0.3 0 0.7
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 1659 ft2 372 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1484 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1484 ft2 0.11 Wood
7/21/2021 9:39 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
I-UKIVI K4Ub-2U2U INI'U 15UMMAKY GFIEGKLI5T REPORT
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing Solar Below
1 E
Exterior Concrete Block - Int Insul Main
4.1 37 4 9
0
336.0 ft'
0
0 0.6
0
2 N
Exterior Concrete Block - Int Insul Main
4.1 20 0 8
0
160.0 ftz
0
0 0.6
0
3 W
Exterior Concrete Block - Int Insul Main
4.1 44 5 9
0
399.8 ft'
0
0 0.6
0
4 S
Exterior Concrete Block - Int Insul Main
4.1 34 8 9
0
312.0 ftz
0
0 0.6
0
5 -
Garage Frame - Wood Main
13 23 7 10 0
235.8 ftz
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
NW Insulated Main
None
.25
3
6 8
20 ftz
2
- Wood Main
None
.25
2
8
6 8
17.8 ftz
WINDOWS
Orientation shown is the entered. Proposed orientation.
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
E 1 Vinyl Low-E Double Yes
0.33 0.23 N
6.9 ftz
1 ft 5 in
0 ft 9 in
None
Exterior 5
2
N 2 Vinyl Low-E Double Yes
0.3 0.21 N
16.2 ft'
1 ft 5 in
0 ft 9 in
None
Exterior 5
3
N 2 Vinyl Low-E Double Yes
0.33 0.31 N
13.3 ft'
5 ft 9 in
0 ft 9 in
None
None
4
W 3 Vinyl Low-E Double Yes
0.33 0.23 N
6.9 ftz
1 ft 5 in
0 ft 9 in
None
Exterior 5
5
W 3 Vinyl Low-E Double Yes
0.33 0.23 N
80.9 ft'
1 ft 5 in
0 ft 9 in
None
Exterior 5
6
S 4 Vinyl Low-E Double Yes
0.55 0.7 N
17.8 ft'
11 ft 5 in
0 ft 10 in
None
None
7
S 4 Vinyl Low-E Double Yes
0.33 0.23 N
16.2 ft'
11 ft 5 in
0 ft 9 in
None
Exterior 5
8
S 4 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft'
1 ft5 in
0 ft9 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
397 ftz 397 ft'
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .0004 1558.2 85.49 160.49
.1324
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
, Electric Heat Pump/ Split
Singl HSPF:8.5
28.2 kBtu/hr
1
sys#1
7/21/2021 9:39 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 28.4 kBtu/hr cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.95 50 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
---- Supply ----
---- Return --- Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 296.8 ft Main
74.2 ft2 Default Leakage Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinJan f X Feb
Mar
Mar
Apr
f APr f
Ma rj Jun X Jul Au
May Jun 4 ] Jul jXj AuSeP
rj Se
Oct
Oct
Nov
Dec
Dec
Ventin Jan [ Feb
X Mar
[X] A r [
Ma Jun [ Jul Aug
Se [X]
Oct
XNov
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6 7
8 9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78 78
78 80
80
80
80
PM
80
80 78
78 78 78 78
78 78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78 78
78 78
78
78
78
PM
78
78 78
78 78 78 78
78 78
78
78
78
Heating (WD) AM
66
66 66
66 66 68 68
68 68
68
68
68
PM
68
68 68
68 68 68 68
68 68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68 68
68 68
68
68
68
PM
68
68 68
68 68 68 68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft2
0 ft 0.3
Main
7/21/2021 9:39 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
r.
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows- Description
a. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.70
c. U-Factor: Dbl, U=0.30
SHGC: SHGC=0.21
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
5318 Vespera Street, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Detached
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
1
c. N/A
3
d. N/A
11. Ceiling Type and insulation level
No
a. Under Attic (Vented)
1484
b. N/A
Area
c. N/A
143.22 ft2
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Main, AH: Main
17.78 ft2
13. Cooling systems
16.19 ft2
a. Central Unit
13.33 ft2
3.503 ft.
0.278
Area
ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1484.00 ft2
b. N/A R= ft2
c. N/A R= ft2
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code comr)liant-features.
Builder SignaturP Date:
Address of New Home:
City/FL Zip:
Insulation Area
R=4.1 1207.80 ft2
R=13.0 235.83 ft2
R=
ft2
R=
ft2
Insulation
Area
R=30.0
1484.00 ft2
R=
ft2
R=
ft2
R ft2
6 296.8
kBtu/hr
Efficiency
28.4
SEER:15.00
kBtu/hr Efficiency
28.2 HSPF:8.50
Cap: 50 gallons
EF: 0.95
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/21/2021 9:39 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1