Loading...
HomeMy WebLinkAboutLetter Of Truss Approval258 Southhall Lane, Suite 200 F D S Maitland, Florida 32751 P: (321) 972-0491 1 F: (407) 880-2304 1 E: info@fdseng.com Website: www.fdseng.com ENGINEERING ABBOCIATES December 16, 2021 Building Department Ref: Adams Homes Lot: Lot 184 Ph.3 Subdivision: Fort Pierce - Waterstone Address: 5318 Vespera St. Model: 1480 B LHG KA # 21-10557 Truss Company: Builders First Source Date of drawings: 8/7/2021 Job No.: 2867130 Wind Speed: 160 Exposure: C Truss Engineer: Joaquin Velez To whom it may concern, SEV5EW` ' FOR 0 Bocc We have reviewed the truss design package for the project referenced above. This truss package complies with the original design intent and the underlying structure will accommodate all• indicated loads. We approve the truss package without comment based upon the truss layout and truss profiles supplied to us by the Truss Company with truss profiles sealed by the Truss Engineer. Please note, this review is only for general conformance with the design concept of the project. Contractor or sub -contractor is responsible for matching all structural components and details shown in the construction documents. Contractor or sub -contractor is also responsible for confirming all quantities and dimensions; selecting appropriate fabrication processes and techniques; and coordinating work with all other trades. Note: Truss ID's may vary. If you have any questions, please do not hesitate to call. Sincerely, <<�111ltiiltl111i1/1�/ F� 6 2 6 — 12/16/2021 12/16/2021 S7" Carl j �I of ,'��E OF Sett Lewkowski, P.E. Luis Pablo Torres, P.E. FL. # 5�6�d, '+.,R lD p:� L�,,4'F. #78750 FL. # 87864 O t Af 1. E °�11r116Jilillllt�l���� "Your1Bu lding1Code E perts"ompany K = THJA26 supporting H9Ns must be installed before E9A's. CONNECTOR SCHEDULE DESCRIPTION QTY T-WA-26 2 .. CIA C3A C5A B03 B03 B04 B04 B04 Q Q Q Q oQD Q Q Q Q Q Q Q Q Q Q aQ0 Q Q Q Q 'I r- W M M 0) O) (M C0 0) C1 D) � r- u7 CM U U U U W W W W W W W W W W W W U U U U tK)\ \ an \ \ \ 12 yp)caj \ \ \ \ \ + \ \ \ \ \ \ ' Flat ypical \ \ \ 8' Flat, Typical \ \ \ \ \ 6 00 E TO 0 Y 0 ND 0 m 0 n 6-00-00 20-00-00 13-00-00 39-00-OD .I A15 A14 A13 Al2 -I ME9 M 'I N6 all'a I 11; 1� TO WIND 0 Reviewed and Approved ❑ Revise and Resubmit 0 Reviewed with Notations ❑ Not Reviewed (see explanation) Corrections or comments made on equipment submittals or shop drawings during this review do not relieve contractor from compliance with requirements of the drawings and specifications. This check is only for review of general conformance with the concept of the project and general compliance with the information given in the contract documents. The contractor is responsible for confirming and correlating all quantities and dimensions; selecting fabrication processes and techniques of construction; coordinating his work with that of all other trades and performing his work in a safe and satisfactory manner FDS ENGINEERING AASSOCIATES Date: 12/17/2021 By: ES /(I Submittal No.: Project No.: 21-10557 Project Eng.: Carl Brown Project Name: Adams Homes - Fort Pierce - Waterston - Lot 184 Blk Ph3 VERH Y ALL DIMENSIONS AND CEILING CONODIONS PRIOR TO APPROVAL SOW CEIUNG FR,VNNG REQUIRED IN RUD BY SULDER MAD! WIND FORCE RES6TING SYSTEWCG HYBRID WIND ASM46 IMPORTANT ENCLOSED FAPOSURE CATEGORY C OCCUPANCY CATEGORY Y This Drawing Must Be Approved And WIHO MWORrLOADISG MPH WINDIMPORTANCEFACTOR 1.00 Returned Before Fabrication Will TRUSSES WIVE BEEN OESIGxEDED FOR ATQDPSF BOTTOM CHORD LNE LOAD Begin, For Your Protection Check All NONCONCURRENT WITH ANY OTHER LIVE LOADS Dimensions And Conditions Prior To Approval 01 Plan. ROOF LOADING FLOOR LOADING SIGNATURE BELOW INDICATES ALL NOTES AND DIMENSIONS HAVE TCLL: 20 PSF TCLL• 40 PSF BEEN ACCEPTED. TCDL• 07 PSF TCDL: 10 PSF By Date BCDL• 10 PSF BCDL: 5 PSF TOTAL, 37 PSF TOTAL: 65 PSF DURATION: 1.25 DURATION: 1.00 CAUTION!!! DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRING TO THE ENGINEERING DRAWINGS AND BSCI-B7 SUMMARY SHEETS. ALL PERMANENT BRACING MUST BE IN PLACE PRIOR TO LOADING TRUSSES. (10. SHEATHING, SHINGLES, ETC.) ALL INTERIOR BEARING WALLS MUST BE IN PLACE PRIOR TO INSTALLING TRUSSES. REFER TO FINAL ENGINEERING SHEETS FOR THE FOLLOWING. 1) NUMBER OF GIRDER PLIES AND NAILING SCHEDULE 2) BEARING BLOCK REQUIREMENTS. 3) SCAB DETAILS (IF REQUIRED) 4) UPLIFT AND GRAVITY REACTIONS. WARNING Backcharges Will Not Be Accepted Regardless of Fault Without Prior Notification By Customer Within 48 Hours And Investigation By Builders First Source. NO EXECPTIONS. The General Contractor Is Responsible For All Connections Other Than Truss to Truss, Gable Shear Wall, And Connections. Temporary and Permanent Bracing, And Ceiling And Roof Diaphragm Connections. ROOF PITCH: 6112 CEILING PITCH: 3112 TOP CHORD SIZE: 2 X 4 BOTTOM CHORD SIZE: 2 X 4 OVERHANG LENGTH: 16" END CUT: Plumb CANTILEVER: TRUSS SPACING: 24" BUILDING CODE: FBC2020 BEARING HEIGHT SCHEDULE BUILDER: - Adams Homes PROJECT: Single Family MODEL 11480 B 10X14 LANAI ADDRESS: I 631SVESPERA ST LOT / BLOCK: 184/ PH3 SUBDIVISION:WATERSTONE CITY: FT PIERCE DRAWN BY: KSANCHEZ JOB H : 2867130 DATE: 08/0512021 SCALE: NTS PLAN DATE: 1 2021 REVISIONS: 1. 2. 3. 4. 4408 Airport Road Plant City, FL 33563 Ph.(813) 305-1300 Fax (813) 305-1301