HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 186 Phase 3 Waterstone 1480 AGR
Builder Name: ADAMS HOMES
Street: 5310 Vespera Street
Permit Office:
City, State, Zip: Port Saint Lucie, FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type01443.6 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1207.80 ftz
b. Frame - Wood, Adjacent
R=13.0 235.83 ftz
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 3
d. N/A
R= ftZ
5. Is this a worst case? No
11. Ceiling Types (1484.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1484.00 ftZ
6. Conditioned floor area above grade (ftz) 1484
b. N/A
R= ftZ
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftZ
7. Windows(190.5 sqft.) Description Area
12. Ducts
R ftz
a. U-Factor: Dbl, U=0.33 143.22 ftz
a. Sup: Attic, Ret: Main, AH: Main
6 296.8
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.55 17.78 ftz
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.70
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.33 16.19 ftz
SHGC: SHang
D1
Area Weighted Average Overhang Depth: 3.419 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.278
a. Electric Heat Pump
28.2 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ftz
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1484.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1484.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
16. Credits
Pstat
Total Proposed Modified Loads: 48.61
Glass/Floor Area: 0.128
PASS
Total Baseline
Loads: 48.94
I hereby certify that the plans s ►cations covered
'Pe"VMW of the plans and
4TI:ST9
this calculation are in compl' the Flori rgy
specifications covered by this
_ _ 0-
Code.
calculation indicates compliance
r
with the Florida Energy Code.
rnd �. F; ro
PREPARED BY:
DATE:_ n7_91_9n91 Winn KPnmany
Before construction is completed
this building will be inspected for
compliance with Section 553.908
`
X.
I hereby certify that this building, as designed, is in compliance
Florida Statutes..5
with the Florida Eee� ode.
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house.
7/21/2021 10:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPLIT SUMMARY rHFrKI IST RFPnRT
----------- ----
PROJECT
----
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 186 Phase 3 Waterstone Bedrooms: 3
User Conditioned Area: 1484
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
186 Phase3
Waterstone
5310 Vespera Street
St. Lucie
Port Saint Lucie ,
FL , 34951
CLIMATE
/
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1484 13356
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1484 13356 Yes 4
3 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 150.8 ft 0
1484 ft2 ----
0.3 0 0.7
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Shed Composition shingles 1659 ft2 372 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1484 ft2 N N
CEILING
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
E#
1
Under Attic (Vented)
Main 30 Blown
1484 ft2 0.11
Wood
7/21/2021 10:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT RIIMMARY CHI:rKI IAT RI=PnRT
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing Solar Below
1 NW Exterior Concrete Block - Int Insul Main
4.1 37 4 9
0
336.0 ft2
0
0 0.6
0
2 NE
Exterior Concrete Block - Int Insul Main
4.1 20 0 8
0
160.0 ft2
0
0 0.6
0
3 SE
Exterior Concrete Block - Int Insul Main
4.1 44 5 9
0
399.8 ft2
0
0 0.6
0
4 SW
Exterior Concrete Block - Int Insul Main
4.1 34 8 9
0
312.0 ft2
0
0 0.6
0
_ 5 -
Garage Frame - Wood Main
13 23 7 10
0
235.8 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
NE Insulated Main
None
.25
3
6 8
20 ft2
2
- Wood Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
NW 1 Vinyl Low-E Double Yes
0.33 0.23 N
6.9 ft2
1 ft 4 in
0 ft 10 in
None
None
2
NE 2 Vinyl Low-E Double Yes
0.33 0.21 N
16.2 ft2
1 ft 4 in
0 ft 10 in
None
None
3
NE 2 Vinyl Low-E Double Yes
0.33 0.31 N
13.3 ft2
5 ft 8 in
0 ft 9 in
None
None
4
SE 3 Vinyl Low-E Double Yes
0.33 0.23 N
6.9 ft2
1 ft 4 in
Oft 10 in
None
None
5
SE 3 Vinyl Low-E Double Yes
0.33 0.23 N
80.9 ft2
1 ft 4 in
0 ft 10 in
None
None
6
SW 4 Vinyl Low-E Double Yes
0.55 0.7 N
17.8 ft2
11 ft 4 in
1 ft 0 in
None
None
7
SW 4 Vinyl Low-E Double Yes
0.33 0.23 N
32A ft2
1 ft 4 in
0 ft 10 in
None
None
8
SW 4 Vinyl Low-E Double Yes
0.33 0.23 N
16.2 ft2
11 ft 4 in
0 ft 10 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
397 ft2 397 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .0004 1558.2 85.49 160.49
.1324
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5
28.2 kBtu/hr
1
sys#1
7/21/2021 10:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY ('.NF['.KI IST RFP(1RT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Sing[ SEER: 15 28.4 kBtu/hr cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
---- Supply ---
--- Return ---
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 296.8 ft
Main
74.2 ft2 Proposed Qn
Main
--- cfm
89.0 cfm 0.06 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
Heatinf X Jan HFeb
Mar
Mar
Apr
f APr f
Jul
May JunJul
May rj Jun ri
X Au
f AuSep
Se
ri
Oct
Oct
Nov
Nov
HX
Dec
Dec
Ventin [ Jan Feb
X Mar
[X]
A r [
Ma Jun Jul
[ Aug
Se
[
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
7/21/2021 10:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
5310 Vesperal Street, Port Saint Lucie, FL, 34951
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows- Description
a. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.70
c. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.21
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
New (From Plans)
10. Wall Type and Insulation
Detached
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
1
c. N/A
3
d. N/A
No
11. Ceiling Type and insulation level
a. Under Attic (Vented)
1484
b. N/A
Area
c. N/A
143.22 ft2
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Main, AH: Main
17.78 ft2
13. Cooling systems
16.19 ft2
a. Central Unit
13.33 ft2
3.419 ft.
0.278
Area
ft2
Insulation Area
R=0.0 1484.00 ft2
R= ft2
R= ft2
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signa Date:
Address of New Home:
City/FL Zip:
Insulation Area
R=4.1 1207.80 ft2
R=13.0 235.83 ft2
R=
ft2
R=
ft2
Insulation
Area
R=30.0
1484.00 ft2
R=
ft2
R=
ft2
R ft2
6 296.8
kBtu/hr
Efficiency
28.4 SEER:15.00
kBtu/hr Efficiency
28.2 HSPF:8.50
Cap: 40 gallons
EF: 0.94
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/21/2021 10:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1