Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 186 Phase 3 Waterstone 1480 AGR Builder Name: ADAMS HOMES Street: 5310 Vespera Street Permit Office: City, State, Zip: Port Saint Lucie, FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type01443.6 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1207.80 ftz b. Frame - Wood, Adjacent R=13.0 235.83 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftZ 5. Is this a worst case? No 11. Ceiling Types (1484.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1484.00 ftZ 6. Conditioned floor area above grade (ftz) 1484 b. N/A R= ftZ Conditioned floor area below grade (ftz) 0 c. N/A R= ftZ 7. Windows(190.5 sqft.) Description Area 12. Ducts R ftz a. U-Factor: Dbl, U=0.33 143.22 ftz a. Sup: Attic, Ret: Main, AH: Main 6 296.8 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.55 17.78 ftz 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.70 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.33 16.19 ftz SHGC: SHang D1 Area Weighted Average Overhang Depth: 3.419 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.278 a. Electric Heat Pump 28.2 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ftz 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (1484.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1484.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 16. Credits Pstat Total Proposed Modified Loads: 48.61 Glass/Floor Area: 0.128 PASS Total Baseline Loads: 48.94 I hereby certify that the plans s ►cations covered 'Pe"VMW of the plans and 4TI:ST9 this calculation are in compl' the Flori rgy specifications covered by this _ _ 0- Code. calculation indicates compliance r with the Florida Energy Code. rnd �. F; ro PREPARED BY: DATE:_ n7_91_9n91 Winn KPnmany Before construction is completed this building will be inspected for compliance with Section 553.908 ` X. I hereby certify that this building, as designed, is in compliance Florida Statutes..5 with the Florida Eee� ode. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house. 7/21/2021 10:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPLIT SUMMARY rHFrKI IST RFPnRT ----------- ---- PROJECT ---- Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 186 Phase 3 Waterstone Bedrooms: 3 User Conditioned Area: 1484 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address 186 Phase3 Waterstone 5310 Vespera Street St. Lucie Port Saint Lucie , FL , 34951 CLIMATE / Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1484 13356 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1484 13356 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 150.8 ft 0 1484 ft2 ---- 0.3 0 0.7 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Barr Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Gable or Shed Composition shingles 1659 ft2 372 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1484 ft2 N N CEILING Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type E# 1 Under Attic (Vented) Main 30 Blown 1484 ft2 0.11 Wood 7/21/2021 10:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT RIIMMARY CHI:rKI IAT RI=PnRT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NW Exterior Concrete Block - Int Insul Main 4.1 37 4 9 0 336.0 ft2 0 0 0.6 0 2 NE Exterior Concrete Block - Int Insul Main 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 3 SE Exterior Concrete Block - Int Insul Main 4.1 44 5 9 0 399.8 ft2 0 0 0.6 0 4 SW Exterior Concrete Block - Int Insul Main 4.1 34 8 9 0 312.0 ft2 0 0 0.6 0 _ 5 - Garage Frame - Wood Main 13 23 7 10 0 235.8 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in 0 ft 10 in None None 2 NE 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 0 ft 10 in None None 3 NE 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 5 ft 8 in 0 ft 9 in None None 4 SE 3 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in Oft 10 in None None 5 SE 3 Vinyl Low-E Double Yes 0.33 0.23 N 80.9 ft2 1 ft 4 in 0 ft 10 in None None 6 SW 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 11 ft 4 in 1 ft 0 in None None 7 SW 4 Vinyl Low-E Double Yes 0.33 0.23 N 32A ft2 1 ft 4 in 0 ft 10 in None None 8 SW 4 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 11 ft 4 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 397 ft2 397 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1558.2 85.49 160.49 .1324 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 28.2 kBtu/hr 1 sys#1 7/21/2021 10:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY ('.NF['.KI IST RFP(1RT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing[ SEER: 15 28.4 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply --- --- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 296.8 ft Main 74.2 ft2 Proposed Qn Main --- cfm 89.0 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb Heatinf X Jan HFeb Mar Mar Apr f APr f Jul May JunJul May rj Jun ri X Au f AuSep Se ri Oct Oct Nov Nov HX Dec Dec Ventin [ Jan Feb X Mar [X] A r [ Ma Jun Jul [ Aug Se [ Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 7/21/2021 10:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 5310 Vesperal Street, Port Saint Lucie, FL, 34951 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.70 c. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.21 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A New (From Plans) 10. Wall Type and Insulation Detached a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Adjacent 1 c. N/A 3 d. N/A No 11. Ceiling Type and insulation level a. Under Attic (Vented) 1484 b. N/A Area c. N/A 143.22 ft2 12. Ducts, location & insulation level a. Sup: Attic, Ret: Main, AH: Main 17.78 ft2 13. Cooling systems 16.19 ft2 a. Central Unit 13.33 ft2 3.419 ft. 0.278 Area ft2 Insulation Area R=0.0 1484.00 ft2 R= ft2 R= ft2 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signa Date: Address of New Home: City/FL Zip: Insulation Area R=4.1 1207.80 ft2 R=13.0 235.83 ft2 R= ft2 R= ft2 Insulation Area R=30.0 1484.00 ft2 R= ft2 R= ft2 R ft2 6 296.8 kBtu/hr Efficiency 28.4 SEER:15.00 kBtu/hr Efficiency 28.2 HSPF:8.50 Cap: 40 gallons EF: 0.94 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/21/2021 10:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1