Loading...
HomeMy WebLinkAboutLetter Of Truss Approval258 Southhall Lane, Suite 200 Maitland, Florida 32751 P: (321) 972-0491 1 F: (407) 880-2304 E: info@fdseng.com Website: www.fdseng.com ENGINEERING ASSOCIATES December 16, 2021 Building Department Ref Adams Homes Lot: Lot 186 Ph.3 Subdivision: Fort Pierce - Waterstone Address: 5310 Vespera St. Model: 1480 A RHG KA # 21-10562 Truss Company: Builders First Source Date of drawings: 8/7/2021 Job No.: 2866845 Wind Speed: 160 Exposure: C Truss Engineer: Joaquin Velez To whom it may concern, We have reviewed the truss design package for the project referenced above. This truss package complies with the original design intent and the underlying structure will accommodate all indicated loads. We approve the truss package without comment based upon the truss layout and truss profiles supplied to us by the Truss Company with truss profiles sealed by the Truss Engineer. Please note, this review is only for general conformance with the design concept of the project. Contractor or sub -contractor is responsible for matching all structural components and details shown in the construction documents. Contractor or sub -contractor is also responsible for confirming all quantities and dimensions; selecting appropriate fabrication processes and techniques; and coordinating work with all other trades. Note: Truss ID's may vary. If you have any questions, please do not hesitate to call. Sincerely, ��ta<<ti1111P1ttl//f��� 1 .6 2 o ? ST ?S Caii J%dtoj� ,I i FL 5V15 O� GF A 4 •• seee 12/16/2021 tt Lewkowski, P.E. #78750 giineering Associates' A TSG Company "Your Building Code Experts" 12/16/2021 Luis Pablo Torres, P.E. FL. # 87864 c C u CI a) 0) W W W a CIA MA MA Ain •5•. .•♦ �0 1 1 i U 1/ A13 � EV • .�� �I I i � III 1 1 ►♦♦. All A 1 ... • r -•V TII 11- as •, ♦ �� .•♦ �I i/ \ ill ii 1� �.. 01 91 A• /'♦ i �' 111 11 MMS .�i �II� 1 II 1 i ••. �� . ♦♦ .�1 11 Typical 8' Flat O 1 1 I d ill 1 1 �ME 08 .54 �I 1 1 1, ♦i �� �� : • I �� �i 111 ii,+� ■ IlllllOi� � � III 11 ':. ,♦ 041 i-. _ �♦ i o i i �♦ �♦ ii-DOI. �� ��♦: U U 6-00-00 U 20-00-00 U K = THJA26 supporting H9A's must be installed before E9A's. CONNECTOR SCHEDULE QTY I DESCRIPTION 2 THJ 6 Z Reviewed and Approved ❑ Reviewed with Notations ❑ Revise and Resubmit ❑ Not Reviewed (see explanation) I CAUTIONM _ DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRING TO THE ENGINEERING DRAWINGS AND BSCI-131 SUMMARY SHEETS. ALL PERMANENT BRACING MUST BE IN PLACE PRIOR TO LOADING TRUSSES. (ie. SHEATHING, SHINGLES, ETC.) ALL INTERIOR BEARING WALLS MUST BE IN PLACE PRIOR TO INSTALLING TRUSSES. REFER TO FINAL ENGINEERING SHEETS FOR THE FOLLOWING. 1) NUMBER OF GIRDER PLIES AND NAILING SCHEDULE 2) BEARING BLOCK REQUIREMENTS. 3) SCAB DETAILS (IF REQUIRED) 4) UPLIFT AND GRAVITY REACTIONS. WARNING Backcharges Will Not Be Accepted Regardless of Fault Without Prior Notification By Customer Within 48 Hours And investigation By Builders First Source. NO EXECPTIONS. The General Contractor Is Responsible For All Connections Other Than Truss to Truss, Gable Shear Wall, And Connections. Temporary and Permanent Bracing, And Ceiling And Roof Diaphragm Connections. ROOF PITCH: 6112 CEILING PITCH: 3112 TOP CHORD SIZE: 2 X 4 BOTTOM CHORD SIZE: 2 X 4 OVERHANG LENGTH: 16" END CUT: Plumb CANTILEVER: — TRUSS SPACING: 24" BUILDING CODE: FBC2020 BEARING HEIGHT SCHEDULE Corrections or comments made on equipment submittals or shop drawings during this review do not relieve contractor from compliance with requirements of the drawings and specifications. This check is only for review of general conformance with the concept of the project and general compliance with the information given in the contract documents. The contractor is responsible for confirming and correlating all quantities and dimensions; selecting fabrication processes and techniques of construction; coordinating his work with that of all other trades and performing his work in a safe and satisfactory manner FDS ENGINEERING ASSOCIATES Date: 12/17/2021 BY ESI/f Submittal No.: Project No.: 21-10562 Project Eng.: Carl Brown Project Name: Adams Homes - Fort Pierce - Waterston - Lot 186 Blk Ph3 _ VERIFY ALL DIMENSIONS AND CEILING CONDIT O?4S PRIOR TO APPROVAL SOME CEILING FRAMING REQUIRED IN REM BY BUILDER BUILDER: Adams Homes PROJECT: Single Family MODEL 1480 A 10X74 LANAI ADDRESS: 1 6310 VESPERA ST LOT/BLOCK: 1861PH3 SUBDIVISION: I WATERSTONE CRY: I FT PIERCEDRAWN BY: KSANCHEZ JOB # : I 2866845 DATE: 1 08/04/2021 SCALE: NTS PLAN DATE: 2021 REVISIONS: 1. 2. 3. 4. MAIN MIND FORCE RESISTING SYSTEwCt HYBRID WIND ASCEMS IMPORTANT ENCLOSED EXPOSURE CATEGORY 1; OOCU CYCATEGORY II This Drawing Must Be Approved And WIND IMPORTANCE FACTOR 1.00 MID LOADIMUO TSO ANCE Returned Before Fabrication Will „ TRUSSES HAVE BEEN DESIGNED FOR A 10.0 PSF BOTTOM CHORD LIVE LOAD Begin. For Your Protection Check All NONOONCURRENT WITH ANY OrNER LIVE LOADS Dimensions And Conditions Prior To APBELO Of Plan. SIGNATURE BELOW INDICATES ALL ROOF LOADING FLOOR LOADING NOTES ND DIMSIONS HAVE TCLL• 20 PSF TCLL: 40 PSF BEEN ACCE TED. TCDL: 07 PSF TCDL: 10 PSF By Date , BCDL" 10 PSF BCDL• 5 PSF TOTAL: 37 PSF TOTAL: 65 PSF DURATION: 1.25 DURATION: 1.00 4408 Airport Road Plant City, FL 33563 Ph. (813) 305-1300 Fax (813) 3057301