Loading...
HomeMy WebLinkAboutEnergy Efficiency Coder "- FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 171 Phase 3 Waterstone 1820 DGL Builder Name: ADAMS HOMES Street: 5309 Vespera Street Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall TypeV120.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1850.00 ft2 3. Number of units, if multiple family 1 b. Frame -Wood, Adjacent R=13.0 270.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= 5. Is this a worst case? No 11. Ceiling Types (1900.0 sqft.) ft2 Insulation Area a. Under Attic (Vented) R=30.0 1820.00 ft2 6. Conditioned floor area above grade (ft2) 1820 b. Knee Wall (Vented) R=19.0 80.00 ft2 Conditioned floor area below grade (ft2) I0 c. N/A R= ft2 7. Windows(237.2 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 168.74 ft2 � a. Sup: Attic, Ret: Main, AH: Main 6 364 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 t 32.38 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 ' a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.33 I 18.33 ft2 SHGC: SHGC=0.31 Area Weighted Average Overhang Depth: 4.181 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.269 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A I 9. Floor Types (1820.0 sqft.) !Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.130 Total Proposed Modified Loads: 58.67 PASS Total Baseline Loads: 64.94 I hereby certify that the plans s I ications covere "' Revie of the plans and ,OFtES,g this calculation are in compl' c nergy specifications covered by this Code. calculation indicates compliance d, �w riA with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 07_21_2021 A/inn Kanmany this building will be inspected for ;r compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance with the Florida Energy Florida Statutes. v -Cade. G, OD' yVfi'i OWNER/A , BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). r (: `z� ? ' l 7/21/2021 2:29 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software J Page 1 of 4 FORM R405-gngn IAIDI IT 011 IRA RR r!kV nI zr-i+v. .ems— .� PROJECT Title: Lot 171 Phase 3 Waterstone Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1820 Lot # 171 Phase3 Owner Name: # of Units: 1 Total Stories: 1 Block/Subdivision: Waterstone Builder Name: ADAMS HOMES Worst Case: No Rotate Angle: 0 PlatBook: Permit Office: Cross Ventilation: No Street: 5309 Vespera Street Jurisdiction: 661000 Whole House Fan: No County: City, State, Zip: St. Lucie Fort Pierce Family Type: Detached , New/Existing: New (From Plans) FL, 34951 Comment: CLIMATE Design Location Design Temp TMY Site 97.5 Int Design Temp Heating Design Daily Temp % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1820 18200 I SPACES Number Name Area IVolume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 33 ft 0 1820 ft2 0.42 ---- 0 0.58 ROOF / V # Type Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1820 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1820 ft2 0.11 Wood 2 Knee Wall (Vented) Main 19 Batt 80 ft2 0.11 Wood 7/21/2021 2:29 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-gngn IAIDI IT c IRARAAMf i+ucnv� ....�■�. v..wr'kL-w 1 lNGrtJF%l WALLS Adjacent Space Cavity Width - Height Sheathing Framing Solar Below o 1 N Exterior Concrete Block - Int Insul Main 4.1 59 0 10 0 590.0 ft2 0 0 0.6 0 2 W Exterior Concrete Block - Int Insul Main 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Int Insul Main 4.1 66 0 10 0 660.0 ft2 0 0 0.6 0 4 E Exterior Concrete Block Int Insul - Main 4.1 27 0 10 0 270.0 ft2 0 0.6 0 5 - Garage Frame - Wood Main 13 27 0 10 0 270.0 ft2 0 0.23 0.01 0 6 W Exterior Concrete Block - Int InsuI Main 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 7 E Exterior Concrete Block Int Insul - Main 4.1 13 0 10 0 130.0 ft2 0 0.6 0 DOORS # Ornt Door Type !Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 i WINDOWS Orientation shown is the entered, Proposed orientation. / V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 2 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 3 W 6 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 9 ft 0 in 0 ft 6 in None None 4 W 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 5 W 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 6 W 6 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 9 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 7 S 3 Vinyl Low-E Double I Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 8 E 7 Vinyl Low-E Double lYes 0.55 0.7 N 17.8 ft2 12 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 9 E 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in Oft 10 in Drapes/blinds Exterior 5 10 E 7 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 12 ft 0 in 0 ft 3 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Areal Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 396 ft2 396 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000444 2123.3 116.49 218.7 .1381 7 7/21/2021 2:29 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4 e FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 i COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split I Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM \ # Svstem Tvne SuhTvna I Ifi— GG r,- V UI 10=1 VO11U11 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftZ I!Return DUCTS ` / -- Supply ---- ---- ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 364 ftz Main 91 ft2 Default Leakage Main (Default) (Default) 1 1 I TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ Jan Heating lX Jan Venting Feb f X� Feb Mar Mar A r f Apr f Jul May �xj Jun Jul Ma Jun rj Au X Augrl I lAugSe Se Sep Oct Oct Nov Dec Dec [ Jan [ Feb X Mar [X] A r [ I Ma Jun Jul [X] Oct XNov X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 31 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 78 80 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 66 68 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftZ 0 ft 0.3 Main 7/21/2021 2:29 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 90 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Windows- Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.21 c. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.31 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 5309 Vespera Street, Fort Pierce, FL, 34951 New (From Plans) 10. Wall Type and Insulation Detached a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Adjacent 1 c. N/A 4 d. N/A No 11. Ceiling Type and insulation level a. Under Attic (Vented) 1820 b. Knee Wall (Vented) Area c. N/A 168.74 ftz 12. Ducts, location & insulation level a. Sup: Attic, Ret: Main, AH: Main 32.38 ftz 13. Cooling systems 18.33 ftz a. Central Unit 17.78 ftz 14. Heating systems 4.181 ft. a. Electric Heat Pump 0.269 Area 15. Hot water systems ftz a. Electric b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ftz Credits (Performance method) b. N/A R= ftz c. N/A R= ftz 1 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature Date: Address of New Home: City/FL Zip: Insulation Area R=4.1 1850.00 ftz R=13.0 270.00 ftz R= ftz R= ftz Insulation Area R=30.0 1820.00 ftZ R=19.0 80.00 ftz R= ftz R ftz 6 364 kBtu/hr Efficiency 35.0 SEER:16.00 kBtu/hr Efficiency 34.6 HSPF:8.50 Cap: 40 gallons EF: 0.94 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/21/2021 2:29 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1