Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 185 Phase 3 Waterstone 1512 BGR Street: 5317 Vespera Street City, State, Zip: Fort Pierce, FL, 34951 Owner: Design Location: FL, ST LUCIE CO INTL Builder Name: ADAMS HOMES Permit Office: Permit Number: Jurisdiction: 661000 County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Typetl642.6 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1347.70 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 294.94 ft2 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1512.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1512.00 ft2 6. Conditioned floor area above grade (ft2) 1512 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(174.2 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Main, AH: Main R ft2 a. U-Factor: Dbl, U=0.33 118.38 ft2 6 302.4 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 35.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 3.466 ft. 14. Heating systems kBtu/hr Efficiency Area.Weighted Average SHGC: 0.275 a. Electric Heat Pump 28.2 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2l 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (1512.0 sqft.) Insulation Area I EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1512.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.115 Total Proposed Modified Loads: 50.19 PASS Total Baseline Loads: 50.06 I hereby certify that the plans this calculation are in comp Code. PREPARED BY: F DATE: (17-91-91171 Winn Kanmany I hereby certify that this building, as desioned, is in compliance with the Florida Ene OWNER/AGE _ DATE: Re-vjZNv of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. - Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/21/2021 5:06 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 1 rUMIVI t<4U5-ZUZU INF'U 15UMMARY CHECKLIST REPORT PROJECT Title: Lot 185 Phase 3 Waterstone Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 1512 Lot # 185 Phase3 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5317 Vespera Street Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL_VERO_BEACH _MUNI I 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volumel 1 Block1 1512 13608 SPACES Number Name Area Volume lKitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1512 13608 I Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 158.9 ft 0 1512 ftz ---- 0.47 0 0.53 ROOF / Roo f Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 i Gable or Shed Composition shingles 1691 Iftz 378 ft' Medium N 0.85 N 0.85 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1512 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1512 ft2 0.11 Wood 7/21/2021 5:06 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 IMP[IT SIIMMARV rN1=rk11 IQT RGDnRT WALLS Adjacent SpacePt Cavity Width Height In Ark-n Sheathing Framing Solar Belo w R-11ahle 1 W Exterior Concrete Block - Int Insul Main 4.1 39 10 8 9 348.5 ft2 0 0 0.6 0 2 NE Exterior Concrete Block - Int Insul Main 4.1 2 3 8 0 18.0 ft2 0 0 0.6 0 _ 3 N Exterior Concrete Block - Int Insul Main 4.1 18 2 8 3 149.9 ft2 0 0 0.6 0 4 NW Exterior Concrete Block - Int Insul Main i 4.1 2 3 8 0 18.0 ft2 0 0 0.6 0 5 E Exterior Concrete Block - Int Insul Main 4.1 53 7 8 7 459.9 ft2 0 0 0.6 0 6 S Exterior Concrete Block - Int Insul Main 41 2 8 7 353.3 ft2 0 0 0.6 0 7 - Garage Frame - Wood Main 14,1 13 35 9 8 3 294.9 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall I Overhang V # Ornt ID Frame Panes NFRC U- actor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 13 ft 0 in 1 ft 4 in None None 2 W 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 NE 2 Vinyl Low-E Double Yes 0.33 0.21 N 10.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 N 3 Vinyl Low-E Double Yes 0.32 0.31 N 3.0 ft2 7 ft 4 in 0 ft 9 in Drapes/blinds None 5 N 3 Vinyl Low-E Double Yes 0.33 0.21 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 6 NW 4 Vinyl Low-E Double Yes 0.33 0.21 N 10.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None I 7 E 5 Vinyl Low-E Double Yes b.33 0.23 N 9.8 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 8 E 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2. 1 ft 4 in 1 ft 0 in Drapes/blinds None 9 S 6 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 6 ft 8 in 0 ft 10 in Drapes/blinds None 10 S 6 Vinyl Low-E Double Yes 0.33 0.23 N 23.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 11 S 6 Vinyl Low-E Double Yes 0.33 0.23 I N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 'GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 390 ft2 390 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1587.6 87.1 163.52 .1324 7 7/21/2021 5:06 PM EnergyGauge® USA 7.0.00 - Flakes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPI IT RI IMMARV rWI:rKl ICT 011=113r1RT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 28.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 28.4 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS ---- Supply ---- V # Location R-Value Area ---- Return --= Location Area Leakage Type Air Handler CFM 25 CFM25 TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 302.4 ft Main 75.6 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y CoolingH Jan H Feb Mar HeatinJan Feb Mar Ventin Jan Feb HX Mar Ceiling Fans: Jul Apr May Jun Jul Apr May' ri Jun rl [X] Apr [ May JunJul u Mug Aug Se f Sep [ Se [X] Oct Oct Oct Nov Nov X Nov Dec Dec Dec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours ,4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 Cooling (WEH) AM 78 PM 78 Heating (WD) AM 66 PM 68 Heating (WEH) AM 66 PM 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 66 66 68 68 68 68 78 78 78 78 68 68 68 68 78 80 78 78 78 78 78 78 68 68 68 68 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 7/21/2021 5:06 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 F06 R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 5317 Vespera Street, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1347.70 ft2 b. Frame - Wood, Adjacent R=13.0 294.94 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1512.00 ft2 6. Conditioned floor area (ft2) 1512 b. N/A R= ft2 7. Windows** Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.33 118.38 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.23 a. Sup: Attic, Ret: Main, AH: Main 6 302.4 b. U-Factor: Dbl; U=0.33 35.00 ft2 SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 17.78 ft2 a. Central Unit 28.4 SEER:15.00 SHGC: SHGC=0.70 d. U-Factor: other (see details) 3.00 ft2 SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.466 ft. a. Electric Heat Pump 28.2 HSPF:8.50 Area Weighted Average SHGC: 0.275 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2EF:0.94 a. Electric Cap: 40 gallons SHGC(AVG): N/A I b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1512.00 ft2 Credits (Performance method) Pstat b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy, Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature• 1 ``� � Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/21/2021 5:06 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1