Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Evaluation Report Modified Bitument Roof System
FtECENED APR 2 2 2022 E; !=Nola QgutY n 2-2-,o 3 - cis REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC IK2- � � 60- MErlsttAttrc/ ADrrlrsFva MpgarmAno.as a Wiwi REFIeREPoICG LAYER MATEliIAtL APPLICAMON SBS-CA2 (SBS, Cold -Applied) Base Ply 'SBS Base, SBS Base-P, SBS PolyBase, SBS Premium Base, SBS Premium Poly Base LL Ply SBS Base, SBS Base-P, SBS PalyBase, SBS Premium Base, SB5 Premium Poly Base Cap Ply SB5 Cap, SBS Cap UltraWhite, SBS FR Cap, SBS Smooth, SBS Premium, SBS Premium UltraWhite, SBS Premium FR, SBS Premium FR Ultrabhite, SBS Glass, SBS Glass UltraWhite, SBS Glass FR, SBS Glass FR UltraWhite BP -AA (Base and Ply sheets, Asphalt - Applied) Base Ply MB Base, Ply IV, Ply VI Hat asphalt at 20-40 Ply Ply IV, Ply VI Base Ply SBS Base, SBS Base-P SBS PolyBase, SBS Premium Base, SBS Premium Poly Base, SBS Smooth SGS-AA Ply SBS Base, SBS Base-P SBS PolyBase, SBS Premium Base, SBS Premium Poly Base, SBS Smooth lbs/square (SBS, Asphalt -Applied) Cap Ply SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS Smooth, SBS Premium, SBS Premium UltraWhite, SBS Premium FR, SBS Premium FR UltraWhite, SB5 Glass, SBS Glass UltraWhite, SBS Glass FR, SBS Glass FR UltraWhite Base Ply SBS Poly Torch Base, SBS Glass Torch Base, SBS Glass Torch Base 1.5, SBS Smooth SBS TA (SBS, Torch -Applied) Ply SBS Poly Torch Base, SBS Glass Torch Base, SBS Glass Torch Base 1.5, SBS Smooth Torch -Applied Cap Ply SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Torch, SBS Torch UltraWhite, SBS FR Torch, SBS FR Torch UltraWhite, SBS Smooth, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS Premium FR Torch, SBS Premium FRTorch UltraWhite Base Ply APP 80 Glass Base, AP P 80 Glass Base-P, APP 160, APP 16", APP 170, APP Premium Base rAPP=TA----.--, 1(AP.P-, Torch -Applied) Piy APP 160, APP 160-P, APP 170, APP Premium Base Torch Applied Cap Ply APP 160, APP 16D-P, APP 170, APP'3.80,,,APP 180-P, APP 180 UltraWhite, APP 180 FR, APP 180 FR UltraWhite, APP Premium FR, APP Premium FR llltraNlhife t -SBS-SA_ --_ `--,�-- -(SBS, self -adhering) Base Ply BASEGARD SA (see speti0c listings) Self -Adhering iSA The following Cap Ply membrane may be installed over sand -surfaced SBS-AA or SBS-TA Base Ply or Ply membranes within asphalt -applied and torch -applied systems noted herein, in which case the following Marrimum Design Pressure (MDP) limitations apply. In no case shall the substitution and the associated limitation be used to'increasd the AADP listing in the table; rather if the particular system is less than or equal to the noted cold-anolied Can Phi limitation. than the ei ihctiti ainn k .-itt.A DECILTYPE SYSTEM -TYPE LISTED CAPPLV ALTERDIATECOLD-APPLIED CAP PLY MEMBRUIE NIDP(PSF) Wood, Steel, Structural Concrete, A_2 B-1 B-2C-1D 2 or E-2 or S95-AA SBS : SBS-CA: SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS Smooth, SBS Premium, SBS Premi arm UrVC, CWF, Gypsum or Recover , , UltraWhite, SBS Premium FR orSBS Premium FR UltraWhite -127.S Structural Concrete, LV'JC (over SBS-CA: SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS Smooth, SBS Premium, SBS Premiu m structural concrete), Gypsum or A-1 or F SBS-AA or SBS-TA UltraWhite, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass UltraWhite, SBS -18D.0 Recover (over structural concrete) Glass FR or SBS Glass FR UltraWhite Structural Concrete, LWC (over structural concrete), Gypsum or A-1 or F SB5-AA, SBS-TA or APP-CA: APP 160 COOL, APP 170 COOL, APP 180 COOL, APP 180 FR COOL or APP 180 FRCOOL Recover (structural over concrete) APP-TA UltraWhite -�•O tl EFc :D FTC, LLC Evaluation Report FSD70.01.08-2-R14 for t- 02- ;-R _4 CertifuoteefAuthorizotion032455 E0!TIDw 2?2'D? F. C t�DPt-1�5 Fr� i:` r�! r 1"s ( + � ri Revisivnla:D9/22J2020 152029 MM O ETC, LLC Firestone Modiified Biturnan Roof SV.tens; (317) 345 3375 Appendix 1, Page 4 of 68 RECEIVED APR 2 2 2022 St. Lucie County Permittina fONEMOJetc. TABLE IC:� ••• •CONSTRUCTION,•or • OR r SYSTEM TYPE C�1: MECHANICALLY ATTACHED INSULATION, BONDEUROOF COVER Top' Insulation Layer Roof Cover (Note 15) System Deck (Note 1) Base Insulation Layer MDP Attach No. (Note 13) Type fasteners Base Ply Ply Cap Ply (per Note 11 (Note Min.19/32-inch One or more layers, any Min. OZ5-inch Dens Deck BP -AA, SBS-AA, (Optional) BP -AA, SBS AA, SBS AA, SBS-TA W-7 plywood at max. 24- combination, loose laid Prime or SECUROCK Gypsum- Note 2 1 per 2.0 ft2 SBS-TA or APP-TA SBS-TA or APP TA or APP-TA -30.0* inch spans Fiber Roof Board Min.19/32-inch One or more layers, any (Optional) One or more SBS-AA, SBS-TA W-8 plywood at max. 24- combination, loose laid Min. 0.5-inch FlberTop Note 2 1 per 2.0 ft' BP -AA or SBS-AA BP -AA, SBS-AA, SBS-TA or or APP-TA -45.0* inch spans APP-TA W-9 Min. 23/324nch plywood at max. 24- One or more layers, any Min. OS -inch Dens -Deck, Note 2 1 per 3.6 fta SBS-AA (Optional) SBS-AA SBS-AA -45.0* inch spans combination, loose laid Dens -Deck Prime SELF -ADHERING BASE: Min. 15/32-inch (Optional) One or more Min. 1-inch RESISTA, GenFlex (Optional) BP -AA, SBS-AA, W-10 plywood at max. 24- layers, any combination, Coated Glass Facer Note 2 1 per 2.7 ft' BASEGARD SA SBS-TA SBS-AA, SBS-TA -40.0* inch spans. loose laid Min. 15/32-inch (Optional) One or more Min. 0.5-inch ISOGARD HD, (Optional) BP -AA, SBS-AA, W-11 plywood at max. 24- layers, any combination, GenFlex HD ISO Note 2 1 per 2.2 ft' SBS-SA SBS-TA SBS-AA, SBS-TA -50.0*. inch spans. loose laid Min.19/32-inch plywood at max. 24- (Optional) One or more layers, Min. 1.5-inch RESISTA, GenFlex Glass long ft Z (Optional) BP-AASBS-AA , , - 2 inch spans, blocked any combination, loose laid Coated Facer, joints staggered 4 ft. Note 2 1 per 1.8 BASEGARD SA SBS-TA SBS-AA, SBS-TA -75.0 max. 78-inch o.c. TABLE • WOOD •EdKS — NEWCONSTRUCTION,••• a OR RECOVER. -SYSTEM TYPE D-2- INSULATED, M ECHANICALLY ATTACHED BASE -SHEET, BONDED ROO'F.COVER Insulation Layer(s) (Note 13) Base or Anchor Sheet Roof Cover (Note 15) System Deck Note 1 ( ) MDP No. Type Attach Base Attach Base Ply Cap Ply (Psf) (Not 11) Min.19/32-inch One or more layers, Prelim. MB Base, Channel 12-inch o.c. in the 4-inch side lap and 18-inch o.c. in (Optional) One or SBS-AA, W-13 plywood at max. 24- any combination Attached Venting Base Note 2 two, equally spaced, staggered rows in the center of more BP -AA, SBS-AA, SBS-TA or -45.0* inch spans the sheet SBS TA or APP-TA APP-TA Min,19/32-inch One more layers, Prelim. Base, Channel 12-inch o.c. in the 4-inch side lap and 12-inch o.c. in (Optional) One or SBS-AA, W-14 plywood at max. 24- any combination o Attached Venting Base - Ve Note 2 two, equally spaced, staggered rows in the center of more BP -AA, SBS-AA, SBS-TA or -52.5 inch spans the sheet SBS-TA or APP-TA APP-TA MEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 7-EDITION (2020) FBC NON-HVHZ EVALUATION Firestone Modified Bitumen Roof Systems, (317) 845-3875 Evaluation Report F8970.01.08-2-1114 for FL984-H14 Revision 14: 09/22/2020 Appendix 1, Page 8 of 69 ONEMOjetc. TABLE DECK APPLICATION TYPE DESCRIPTION PAGE IA Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation; Bonded Roof Cover 7 115 Wood New, Reroof (Tear -Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 7 iC Wood New, Reroof (Tear -Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 7-8 1D Wood New, Reroof (Tear -Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 8 1E Wood_ New or Reroof (Tear -Off) E-2 Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 9-10 1F Wood New, Reroof (Tear -Off) or Recover E-2 Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 10 2A Steel or Structural Concrete New, Reroof (Tear -Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 11-17 2B Steel or Structural Concrete New, Reroof (Tear -Off) or Recover B-2 Mech. Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover 17-19 2C Steel or Structural Concrete New, Reroof (Tear -off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 19-25 2D Steel or Structural Concrete New, Reroof (Tear -Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 25-26 3A Structural Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 27-33 3B Structural Concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 34 4A Lightweight concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 35-49 4B Lightweight concrete New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 49-50 4C Lightweight concrete New or Reroof (Tear -Off) E-2 Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 51-55 4D Lightweight concrete New or Reroof Uea - E-Z--_Nandnsulated,Mech_AttachedBaseSheet BondecLRoof_Cover__. ___ 55 SA Cementitious Wood Fiber Reroof(Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 56 56 Cementitious Wood Fiber Reroof (Tear -Oft) or Recover A-2 Mech. Attached Anchor Sheet, Bonded insulation, Bonded Roof Cover 56 5C Cementitious Wood Fiber Reroof (Tear -Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 57 SO Cementitious Wood Fiber Reroof (Tear -Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 57 5E Cementitious Wood Fiber Reroof (Tear -Off) or Recover 0-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 57 5F Cementitious Wood Fiber Reroof (Tear -Off) or Recover E-2 Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 58 6A Gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 59-60 68 Gypsum Reroof (Tear -Off) A-2 Mech, Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 60-61 6C Gypsum Reroof (Tear -Off) B-1 Mech. Attached Base Insulation, Bonded Top insulation, Bonded Roof Cover 61 6D Gypsum Reroof (Tear -Off) C-1 Mech. Attached Insulation, Bonded Roof Cover 62 6E Gypsum Reroof (Tear -Off) D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 62 6F Gypsum Reroof (Tear -Off) E-2 Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 62 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 63-68 NEiMOETIC, LLC Evaluation Report F8970.01.08-2-R14 for FL984-R14 LerVjicate ofAuthorizatlon#32455 77"EDITION (2020) FBC NON-HVH2 EVALUATION Revision 14:09/22/2020 ©2019 NEMO ETC, LLC Firestone Modified Bitumen Roof Systems; (317) 84S-3875 Appendix 1, Page 1 of 68 NNEMOjetc. The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Unless otherwise noted, fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: i Wood Deck: Firestone Insulation Fastening Plates with Firestone All -Purpose Fasteners; Firestone Pre -Assembled Fastener and Plate (consisting of 0.196-inch thread diameter fastener with 3-inch diameter metal plate). Minimum 1-inch plywood penetration or wood plank embedment. i Steel Deck: Firestone Insulation Fastening Plates with Firestone All -Purpose Fasteners or Firestone Heavy -Duty Fasteners; Firestone Pre -Assembled Fastener and Plate (consisting of 0.196-inch thread diameter fastener with 3-inch diameter metal plate); Firestone Pre -Assembled Heavy -Duty Fastener and Plate (consisting of 0.275-inch thread diameter fastener with 3-inch diameter metal plate); AP AccuTrac; HD AccuTrac. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. Y Structural Concrete: Firestone Insulation Fastening Plates with Firestone Heavy -Duty Fasteners or Firestone Concrete Drive Fasteners; Firestone Pre -Assembled Heavy -Duty Fastener and Plate (consisting of 0.275-inch thread diameter fastener with 3-inch diameter metal plate); HD AccuTrac. Minimum 1-inch embedment into pilot hole in accordance with published installation instructions. Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 15D5 and, forfoam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non - wind -uplift -related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt: Full coverage, 20-40lbs/square. ➢ Firestone I.S.O. FIX II: Continuous 0.75-inch beads, 8-inch o.c. ➢ Firestone I.S.O. Spray R: Continuous0.5 to 0.75-inch ribbons, 12-inch o.c. ➢ Firestone I.S.O. Stick: Continuous 0.75 to 1-Inch wide ribbons,l2-inch o.c. ➢ Firestone I.S.O. Twin Pack: Continuous 0.5 to 0.75-inch beads,12-inch o.c. ➢ Firestone LiquiGard: Continuous 0.7S to 1-Inch wide ribbons,l2-inch o.c. ➢ Firestone Multi -Purpose MB Cold Adhesive: Full coverage,1.5 to 2 gal./square. .^ ICP Adhesives Polyset CR-20: Continuous 2.5-3.5-inch wide ribbons,l2-inch o.c. > Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. Unless otherwise noted, all insulations are flat-stockor taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations maybe substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table. ➢ Hot asphalt: MDP -120.0 psf (Min. 0.5-inch thick) ➢ Firestone I.S.O. FIX II: MDP -112.5 psf (Min. 0.5-inch thick) ➢ Firestone I.S.O. Stick: MDP -187.5 psf (Min. 0.5-Inch thick) ➢ Firestone I.S.O. Twin Pack or I.S.O. Spray R: MDP -157.5 psf (Min. 0.5-inch thick) ➢ ICP Adhesives Polyset CR-20: MDP -117.5 psf (Min.1.0-inch thick) 8 For adhered roof insulation and board -size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). NEMO ETC, LLC Evaluation Report 178970.01.08-2-1114 for FL984-1114 Certificate ofAuthorizatiorr#32455 7r"EDITION (2020) FBC NON-HVHZ EVALUATION Revision 14:09/22/2020 ©2019 NEMO ETC, LLC Firestone Modified Bitumen Roof Systems; (317) 845-3875 Appendix 1, Page 2 of 68 NNEMOletc. 9 For mechanically attached components or partially -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk" carry the limitations set forth in Section 2.2.10.1 of FM loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted forthese systems. 11 For mechanically attached components over existing decks, fasteners shall betested in the existing deckfor withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re -roof (tearoff) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer, Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 25, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, referto current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness Is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent` LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC `-CER1592)..- -Use-of these- istings In new construction or re=roof (tear -off) applications is at -the discretion of the Designer-orRecordand Authority Having -Jurisdiction: 15 For bonded membrane applications, unless otherwise noted, refer to the following. _ MEMBRANE/ ADHESIVE COMBINATIONS REFERENCE LAVER MATERIAL APPLICATION BP -CA Base Ply MB Base (Base and Ply sheets, Cold- Applied) Ply PIyVI Base Ply SBS Base, SBS Base-P, SBS PolyBase, SBS Premium Base, SBS Premium Poly Base SBS-CA Ply SBS Base, SBS Base-P, SBS PolyBase, SBS Premium Base, SBS Premium Poly Base Firestone Multi -Purpose MB Cold Adhesive 1.5 SBS, Cold -A lied ( PP � ) Ca P Ply SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS Smooth, SBS Premium, SBS Premium UltraWhite, SBS Premium FR, SBS Premium FR at - 2.0 gal/square UltraWhite, SBS Glass, SBS Glass UltraWhite, SBS Glass FR, SBS Glass FR UltraWhite APP-CA Base Ply APP 80 Glass Base, APP 80 Glass Base-P, APP 160-P, APP 160 COOL, APP 170 COOL, APP Premium Base (APP, Cold -Applied) Cap Ply APP 160-P, APP 160 COOL, APP 170 COOL, APP 180-P, APP 180 COOL, APP 180 FR COOL, APP 180 FR COOL UltraWhite, APP Premium FR,APP Premium FR UltraWhite BP-CA2 Base Ply MB Base Firestone LiquiGard (Base and Ply sheets, Cold- Membrane Adhesive at Applied) Ply Ply VI 1.5 - 2.0 gal/square MEMO ETC, LLC Certlficote ofAuthorization #32455 02019 NEMO ETC, LLC 7-EDFTION (2020) FBC NON-HVHZ EVALUATION Firestone Modified Bitumen Roof Systems; (317) 845-3875 Evaluation Report F8970.01.08-2-R14 for FL984-R14 Revision 14: 09/22/2020 Appendix 1, Page 3 of 68 MEMBRANE/ ADHESIVE COMBINnoNS REFERENCE LAYER MATERIAL APPLICATION Base Ply SBS Base, SBS Base-P, SBS PolyBase, SBS Premium Base, SBS Premium Poly Base SBS-CA2 Ply SBS Base, SBS Base-P, SBS PolyBase, SBS Premium Base, SBS Premium Poly Base (SBS, Cold -Applied) Cap Ply SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS Smooth, SBS Premium, SBS Premium UltraWhite, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass UltraWhite, SBS Glass FR, SBS Glass FR UltraWhite BP -AA Base Ply MB Base, Ply IV, PIVVI (Base and Ply sheets, Asphalt - Applied) ply Ply IV, Ply VI Base Ply SBS Base, SBS Base-P SBS PolyBase, SBS Premium Base, SBS Premium Poly Base, SBS Smooth Hot asphalt at 20-40 SBS-AA Ply SBS Base, SBS Base-P 5B5 PolyBase, SBS Premium Base, SBS Premium Poly Base, 585 Smooth Ibs/square (SBS, Asphalt -Applied) Cap Ply SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS Smooth, SBS Premium, SBS Premium UltraWhite, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass UltraWhite, SBS Glass FR, SBS Glass FR UltraWhite Base Ply SBS Poly Torch Base, SBS Glass Torch Base, SBS Glass Torch Base 1.5, SBS Smooth SBS TA Ply SBS Poly Torch Base, SBS Glass Torch Base, SBS Glass Torch Base 1.5, SBS Smooth (SBS, Torch -Applied) Cap Ply SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Torch, SBS Torch UltraWhite, SBS FR Torch, SBS FRTorch UltraWhite, SBS Smooth, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch UltraWhite Torch -Applied — -Base-Ply-- --APP-80 Glass -Base, APP 80Glass Base-P, APP-160, APP-160-P, APP-170,-APP-Premium-Base APP-TA Ply APP 160, APP 160-P, APP 170, APP Premium Base Torch (APP, Torch -Applied) Cap Ply APP 160, APP 160-P, APP 170, APP 180, APP 180-P, APP 180 UltraWhite, APP 180 FR, APP 180 FR UltraWhite, APP Premium FR, APP Premium FR UltraWhite -Applied SBS-SA (SBS, self -adhering) Base Ply BASEGARD SA (see specific listings) Self -Adhering g 15A The following Cap Ply membrane maybe installed over sand -surfaced SBS-AA or SBS TA Base Ply or Ply membranes within asphalt -applied and torch -applied systems noted herein, in which case the following Maximum Design Pressure (MDP) limitations apply. In no case shall the substitution and the associated limitation be used to'increase' the MOP listing in the table; rather if the particular system is less than or equal to the noted cold -applied Cap Ply limitation, then the substitution is permitted. DECKTYPE SYSTEM TYPE LISTED CAP PLY ALTERNATE COLD -APPLIED CAP PLY MEMBRANE MDP (PSF) Wood, Steel, Structural Concrete, A-2, B-1, B-2, C-1, D-2 or E-2 SBS-AA or SBS-TA SBS-CA: SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS Smooth, SBS Premium, SBS Premium -127.5 LWC, CWF, Gypsum or Recover YP UltraWhite, SBS Premium FR or585 Premium FR UltraWhite Structural Concrete, LWC (over SBS-CA: SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS Smooth, SBS Premium, SBS Premiu in structural concrete), Gypsum or A-1 or F SBS-AA or SBS-TA UltraWhite, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass UltraWhite, SBS -180.0 Recover (over structural concrete) Glass FR or SBS Glass FR UltraWhite Structural Concrete, LWC (over structural concrete), Gypsum or A-1 or F SBS-AA, SBS-TA or APP-CA: APP 160 COOL, APP 170 COOL, APP 180 COOL, APP 180 FR COOL or APP 180 FR COOL -225.0 Recover (structural over concrete) APP-TA UltraWhite MEMO ETC, LLC Certificate of Authorization #32455 ©2019 MEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Firestone Modified Bitumen Roof Systems; (317) 845-3875 Evaluation Report F8970.01.08-2-R14 for FL984-R14 Revision 14: D9/22/2020 Appendix 1, Page 4 of 68 ONEMOletc. 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MOP limitations. The lesser of the MDP listings below vs. those in Table 3A aonlies VAPOR: •N$-,STRUCT011AL CONCRETE DECA, FPLL0Wt1J13YADHE5JVE-APPL1ED INSULATION OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE MOP (PSF) TYPE (NOTE 15) APPLICATION C-VB-1. ASTM D41 Base Ply: BP -CA, SBS-CA, APP-CA Multi -Purpose MB Cold Adhesive Multi -Purpose MB Cold Adhesive -67.5* C-VB-2. None MB Base LiquiGard I.S.O. Spray R,12-inch c.c. -240.0* C-VB-3. None MB Base LiquiGard I.S.O. Twin Pack,12-inch o.c. -240.0* C-VB-4. I None Base Ply: SBS-CA2 LiquiGard I.S.O. Spray R,12-inch o.c. -240.0* C-VB-S, I None Base Ply: 5B5 CA2 LiquiGard 1.5.0. Twin Pack,12-inch o.c. -240.0* C-VB-6. ASTM D41 MB Base I.S.O. Twin Pack, 4-inch a.c. I.S.O. Twin Pack,12-inch o.c. -232.5* C-VB-7. ASTM D41 1 or 2 plies Ply IV or PIV VI or 1 ply MB Base, SBS Base, SBS Polybase or SBS Premium Base Hot asphalt Hot asphalt -120.0 * C-VB-B. ASTM D41 1 or 2 plies Ply IV or PIV VI or 1 ply MB Base, SBS Base, SBS Polybase or SBS Premium Base Hot asphalt I.S.O. Spray R or I.S.D. Twin Pack,12-inch o.c. -495.0* C VB-9. ASTM D41 Base Ply: SBS-TA Torch -applied I.S.O. Spray R or I.S.D. Twin Pack,12-inch o.c. -495.0* C-VB-10. V-Force SB Primer V-Force Vapor Barrier Self -adhering I.S.O. Spray R,12-inch o.c. -255.0* C-VB-11. V-Force SB Primer V-Force Vapor Barrier Self -adhering I.S.O. Stick,12-inch o.c. -262.5* C-VB-12. V-Force SB Primer V-Force Vapor Barrier I Self -adhering I.S.O. Twin Pack,12-inch o.c. -255.O* 17 ___An optional air/_v_apor barrier of_V_Eo-rmlaRor3Auier-Membrane, selfzadhered,maybeinstalledatopsteeLrnof-decks (Tables2A.through-2C).prior-to_installation_of.any steel -deck roof _assembly- noted. herein.. 18 "MOP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads NEMO ETC, LLC Certificate ofAuthorization #32455 ©2019 MEMO ETC, LLC 7-EDITION (2020) FBC NON-HVHZ EVALUATION Firestone Modified Bitumen Roof Systems, (317) 845-3875 Evaluation Report F8970.01.08-2-1114for FL984-R14 Revision 14: 09/22/2020 Appendix 1, Page 5 of 68 NNEMOIetc. WOOD B B • . • • • • • B M ECHANICALLY ATTACHED : : • • i ' • F COVER System Deck Base Sheet Roof Cover (Note 15) No. (Note 1) Base Fasteners Attach Base Ply Cap Piy MOP (Psf) (Note u) Min.19/32-inch plywood W-28 at max. 24-inch spans, MB Base, Channel Venting FBC HVHZ 1519.5.1 9-inch D.C. at the 2-inch side lap and 9-inch o.c. atthree (3), gpSEGARD SA 565-AA, SBS- _52.5 blocked max. 794ncho.C. Base nails &tin caps equally spaced, staggered rows in the center of the sheet TA ••B BCONSTRUCTION,°•• • .• RECOVER SYSTEM TYPE E-2- NO B M ECHANICALLY ATTACIJEb: :• i• i• F COVER System Base Sheet Deck Roof Cover (Note 15) MOP Base Ply Cap Ply No. Fasteners (Note 1) Base Attach (Psf) (Note 11) COLD -APPLIED BASE PLY; FIRESTONE LIQu1GARD MEMBRANE ADHESIVE: - - W 29 Min.19/32-inch plywood at max. 24- MB Base, Channel Note 2 12-inch D.C. in the 3.5-inch side lap and 12-inch D.C. in two (2), equally (Optional) One or more SBS-CA2, SBS- inch spans, blocked max. 78-inch o.c. Venting Base spaced, staggered rows in the center of the sheet BP-CA2, SBS-CA2 AA, SBS-TA -� 0 ASPHALT OR TORCH APPLIED BASE PLY: `-Ilft 30- —Min 19/32 Toth -plywood atmax_24-_ .. -ma .Sase,Lhannei- - - NRe --12-inch o.c.-In they inch -side lap and -l2 inchv:c. in two (Z); equally - (Optional) One or_more -5B5 AA SBS TA inch spans attached Venting Base spaced, staggered rows in the center of the sheet BP_AA� SBS-AA SBS-TA or APP-TA _52.5 or APP-TA W-31 Min.19/32-inch plywood at max. 24- MB Base, Channel 12-inch D.C. in the 3.5-inch side lap and 12-inch o.c. in two (2), equally (Optional) One or more SBS-CA2, SBS- inch spans, blocked max. 78-inch D.C. Venting Base Note 2 spaced, staggered rows in the center of the sheet BP -AA, SBS-AA or SBS- AA, SBS-TA _60.0 TA W 32 Min. 19/32-inch plywood at max. 24- MB Base, Channel Note 2 12-inch D.C. in the 2-inch side lap and 12-inch o.c. in two (2), equally One or more BP -AA, S135-CA2, S135- inch spans, blocked max. 78-inch o.c. Venting Base spaced, staggered rows in the center of the sheet SBS-AA or SBS-TA AA, SBS-TA _75.0 SELFADHERING BASE PLY: W-33 Min.19/32-inch plywood at max. 24- MB Base, Channel 12-inch o.c. in the 2-inch side lap and 12-inch D.C. in two (2), equally inch spans, blocked max. 78-inch D.C. Venting Base Note 2 spaced, staggered rows in the center of the sheet BASEGARD SA SBS-AA, 585 TA -75.0 NEMO ETC, LLC Certificate ofAuthorization #32455 @2019 NEMO ETC, LLC 7- EDITION (2020) FBC NON-HVHZ EVALUATION Firestone Modified Bitumen Roof Systems, (317) 845-3875 Evaluation Report F8970.01.08-2-R14 for FL984-1174 Revision 14:D9/22/2020 Appendix 1, Page 10 of 68