HomeMy WebLinkAboutEvaluation Report Roofing UnderlaymentsCREEK Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, fH EDITION (2020) Manufacturer: ATLAS ROOFING CORPORATION Issued October 16, 2020 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 (770) 612-6267 www,atlasroofing.com Quality Assurance: PRI Construction Materials Technologies, LLC (QUA9110) SCOPE Category: Roofing Subcategory: I Underlayments Code Edition: Florida Building Code, 7' Edition (2017) including High -Velocity Hurricane Zones (HVHZ) Code Sections: j 1507.1.1, 1518.4, 1523.1.1, 1523.6.5.2.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST6049) ATL-033-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) ATL-068-02-01 ASTM D 1970 2015a ASTM D 4798 2011(2016) TAS 110 2000 PRI Construction Materials Technologies (TST6049) ATL-069-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-149-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-164-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-254-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-255-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) BWR-534-02-01 ASTM D 1970 2015a ASTM D 4798 2011(2016) TAS 110 2000 PRI Construction Materials Technologies (TST6049) BWR-543-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MBA-004-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST6049) MSA-026-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) WRMI-011-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-004-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST6049) MSA-026-02-01.1 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-030-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-047-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-054-02-01.1 TAS 103 2020 TAS 110 2000 PRI Construction Materials Technologies (TST6049) MSA-057-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-062-02-01.1 ASTM D 1623 2017 PRI Construction Materials Technologies (TST6049) 10SBT0002 TAS 110 2000 PRI Construction Materials Technologies (TST6049) 1085T0007 ASTM D 1623 2017 PRI Construction Materials Technologies (TST6049) 117T11001 ' ASTM D 1623 2017 PRI Construction Materials Technologies (TST6049) 117T0004 TAS 110 2000 PRI Construction Materials Technologies (TST6049) 117T0005 UL 1897 2012 PRI Construction Materials Technologies (TST6049) 1085T0011 ASTM D 1623 2017 i TAS 103 2020 UL LLC (TST1740) 02-NIC40952 ASTM D 1970 2015a UL LLC (TST1740) 02-NK40952 ASTM D 226 2009 UL LLC (TST1740) 02-NI(40952 ASTM D 2626 2004(2012)E1 UL LLC (TST1740) 02-NK40952 ASTM D 4869 D 2016 2003 UL LLC (TST1740) 02-NK40952 ASTM 6$80 (2013)E1 ATL14001.7A FL17�22-R7 Page 1 of 6 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assur,ince changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, inst Illation, recommended use, or other product attributes that are not specifically addressed herein. HCREEK TECHNICAL SERv10Es, LLC PRODUCT DESCRIPTION ATLAS ROOFING CORPORATION Roofing Underlayments #15 Specification Felt ASTM D 226, Type I asphalt saturated organic felt underlayment for use in the HVHZ. #30 Organic Saturated Felt ASTM D 4869, Type Il asphalt saturated organic felt underlayment for use in the non-HVHZ only. #30 Specification Felt ASTM D 226, Type II asphalt saturated organic felt underlayment for use in the HVHZ and non-HVHZ. #43 Base Sheet ASTM D 2626 asphalt saturated and coated, non -perforated, organic felt underlayment for use in the HVHZ and non-HVHZ. #90 Mineral Surface Roll ASTM D 6380, Class M asphalt -saturated organic roll roofing sheet for use in the Roofing HVHZ and non-HVHZ. Gorilla Guard® EVERFELT 30 Asphalt -saturated organic felt underlayment reinforced with glass fiber that meets the performance requirements of ASTM D 226, Type I for use in the HVHZ. Slate/Tile Underlayment ASTM D 6380, Class M asphalt -saturated organic roll roofing sheet for use in the HVHZ and non-HVHZ. WeatherMasterO Ice and ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a Water 100 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. WeatherMaster@ Ice and ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a Water 200 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split -release film, which Is removed during Installation. WeatherMasteri) Ice and ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a Water 216 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split -release film, which is removed during installation. WeatherMaster@) Flexible Ice ASTM D 1970 SBS modified, self -adhering underlayment with plastic film surface and Water for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split -release film, which is removed during installation. WeatherMaster@ Pro -Grade ASTM D 1970, TAS 103, and FRSArrR1 Florida High Wind Concrete and Clay Ice and Water Tile Installation Manual, Sixth Edition compliant compliant SBS modified, self - adhering underlayment with a fiberglass mat reinforcement and a poly -fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during Installation. WeatherMaster@ Tile ASTM D 1970, TAS 103, and FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition compliant compliant SBS modified, self - adhering underlayment with a fiberglass mat reinforcement and a poly -fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during Installation. ATL14001.7A FL17322-R7 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK ATLAS ROOFING CORPORATION Roofing Underlayments TECHNICAL SERVICES, LLC APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation Instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. Exposure of the underlayments shall be limited to a maximum 30 days except as follows: a) #15 Specification Felt, #30 Specification Felt, and #40 Base Sheet — exposure for greater than 24 hours may adversely affect product performance b) WeatherMaster@ Ice and Water 100, WeatherMaster@) Ice and Water 200, WeatherMaster@ Ice and. Water 216 — maximum 45 days c) WeatherMaster@ Pro -Grade Ice and Water— maximum 180 days d) WeatherMasterG Tile — maximum 180 days Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as indicated in other current FBC product approval documents): a) WeatherMaster@ Pro -Grade Ice and Water — DAP Touch 'n Seal Storm Bond Roof Tile Adhesive or DuPont Tile Bond b) WeatherMaster@) Tile — DAP Touch 'n Seal Storm Bond Roof Tile Adhesive or DuPont Tile Bond All ble Roof Coverin sn owa h ,y f Metal Roof Composite Wood :. Clay and ! ' _ Asphalt Panels and or Photovoltaic Shingles Slate Concrete.. ,Underla ant' .. 1 ' Sfifii lles "..,Shin les SF in les . and:Shakes Shari Ies The #16 Specification Felt (HVHZ Y Y N YZ Y N only) #30 Organic Saturated Felt Y Y Y Y Y N #30 Specification Felt Y Y Y Y Y Y #43 Base Sheet Y Y Y N Y Y #90 Mineral Surface Roil Y, N N N N Y Roofing Gorilla Guard® EVERFELT 30 Y Y Y YZ Y N Slate/Tile Underlayment Y1 N N N N Y WeatherMaster4l) Ice and Y Y Y N Y N Water 100 WeatherMaster® Ice and Y Y Y N Y N Water 200 WeatherMasterO Ice and Y Y Y N Y N Water 216 WeatherMasterlD Flexible Ice Y Y Y N Y N and Water weatherMasterel Pro -Grade Y Y Y N Y Y Ice and Water WeatherMaster@ Tile Y Y Y N Y Y Notes: 1) Open valley applications per 1607.2.9.2 2) Wood shingles only ATL14001.7A FL17322-R7 Page 4 of 6 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK ATLAS ROOFING CORPORATION Roofing Underlayments TECHNICAL Srmwleea, LL.0 WIND RESISTANCE (NON-HVHZ ONLY) The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlayment System No.1 — WeatherMaster(l Tile only Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c. Underlayment: WeatherMaster@ Tile shall be fully adhered to the optionally primed plywood deck. Maximum Design -62.5 psf Pressure: Underlayment System No 2 — WeatherMaster@ Pro -Grade Ice and Water only Roof Deck: Min. 15/32-inch APA plywood attached to wood supports spaced a maximum 24" o.c. Underlayment: WeatherMaster@ Pro -Grade Ice and Water shall be backnailed 12-inches o.c. to the plywood deck using min. 129a, 1-1/4" galvanized, ring shank roofing nails with min. 32ga 1-5/8" diameter tin caps. Maximum Design -105 psf Pressure: LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Roof slope limitations shall be in accordance with FBC requirements. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Products described within this report may be used as described in other current FBC product approval documents. 5) Roof coverings shall not be adhered directly to the underiayment unless otherwise approved in this or other current FBC product approval documents. 6) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. ATL14001.7A FL17322-R7 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT ATLAS ROOFING CORPORATION Roofing Underlayments The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building Code, 7'h Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. ,,,,,lllnlrr R=} " 2020.10.16 �� RY . P ,y'ii. No 74021 _ • • *. UWmNWnaryLd•y�P.•M,1 ..._—...:a�_T.. 1. • =-04'00' �10 STATE OF •?�1/ '�'•'•;A-� Zachary R. Priest, P.E. �i,�ss • � R ••'�G % Florida Registration No. 74021 �i ONA\- 1� Organization No. ANE9641 �r1111111110 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest in any other entity Involved in the approval process of the product. END OF REPORT ATL14001.7A FL17322-R7 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. r RECEIVED CREEK ATLAS ROOFING CORPORATION APR 2 2 2022 Roofing Underlayments TECHNICAL Sr=RVICES, LLG` St. Lucie County APPLICATION METHOD Permitting Fnstallation shall be in accordance with the published manufacturer's Installation Instructions, the PSG, and the requirements below. Deck substrates shall be clean, dry, and free from any Irregularities and debris. All fasteners In the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. Exposure of the underlayments shall be limited to a maximum 30 days except as follows: a) #15 Specification Felt, #30 Specification Felt, and #40 Base Sheet — exposure for greater than 24 hours may adversely affect product performance b) WeatherMaster® Ice and Water 100, WeatherMaster@ Ice and Water 200, WeatherMaster® Ice and Water 216 — maximum 45 days c) WeatherMasterfal Pro -Grade Ice and Water — maximum 180 days d) WeatherMaster(ID Tile — maximum 180 days Self -adhering underlayments may be adhered to primed or unprimed plywood substrates In the non-WHZ. Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as Indicated in other current FBC product approval documents): a) WeatherMaster® Pro -Grade Ice and Water — DAP Touch 'n Seal Storm Bond Roof Tile Adhesive or DuPont Tile Bond b) WeatherMaster® Tile — DAP Touch 'n Seal Storm Bond Roof Tile Adhesive or DuPont Tile Bond runuw+auia Mui wvann a. Composite Metal Roof ' or Wood Clay and' Asphalt ' . Panels and .: Photovoltaic Shingles Slate Concrete _ Underia ant Shingles 'Shinled Shln les and Shakes' Shinales. Tile #16 Specification Felt (HVHZ Y Y N Ya Y N only) 830 Organic Saturated Felt Y Y Y Y Y N #30 Specification Felt Y Y Y Y Y Y 843 Base Sheet Y Y Y N Y Y #80 Mineral Surface Roll Yr N N N N Y Roofing Gorilla Guard® EVERFELT 30 Y Y Y YZ Y N Slate/Tile Undedayment. _ Y' N N N N Y `WeathorMaststO Ice and " Y i Y Y N Y N Water 100 W WeatherMaster V Ice and Y Y Y N Y N Water 200 WeatherMacter® Ice and y Y Y N Y N Water 216 WeatherMeater0 Flexible Ice Y Y Y N Y N and Water Weathemaster® Pro -Grade Y Y Y N Y Y Ice and Water WeatherMaster® Tile Y Y Y N Y Y Notes: 1) Open valley applications per 1ou7.2.e.2 2) Wood shingles only ZW_0—0. 52— REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC `'�_ FILE COPY ATL14001.7A FL17322-R7 Page 4 of 6 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. RECEIVED APR 2 2 2022 Ak IRA St. Lucie County NEMO I etc. TABLE''1:,ASRH4:r,SHINGLE.CO,MPONENTS . Type. ` Product Plant(s) Material: Standard : Description.;", Berkshire' Hip and Ridge MN Shingles with Sealant—, Hip and : •' ' fiberglass reinforced, hip and ridge Dur Midge• Hip and Ridge MN Ridge - .: -Shingles•with•Sealant ASTM D3462 asphalt roof shingles ProEdge° GA, CA, OH, OR -,Shingles = WeatherGuard' HP Hip and TN Ridge Shingles 5.1 5.2 5.3 5.4 5.5 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert N(eminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or design guidance unless retained specifically for that purpose. This Evaluation Report is not for use In FBC High Velocity Hurricane Zone Jurisdictions (i.e., Broward and Miami - Dade Counties). This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. Wind.Classification:. Refer.to.Section.6 fo.r.installation requirements to. meet wind classifications tABLE 2A. WIND,CIASSIFlCATIONSi ASPHALTSHINGLES - -Product FBC Table 1507.2.7.1 ouR90S.2.6.1 " Supreme' Berkshire' ;Duration' Premium' Duration' Premium TruDefinition'-Duration' ASTM•D3161(F) & ASTM,D7158(H). TruDeflnition' Duration' Designer Color Collection Oakridge' TruDeflnition' Oakridge' WeatherGuard' HP 5.5.1 Classification by ASTM D7158: ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations, Contact the shingle manufacturer for data specific to each shingle. NEMO ETC, LLC Evaluation ReportO37940-02-12-Rll CertljknteofAuthorization 832455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL106741116 Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 3 of 10