HomeMy WebLinkAboutEvaluation Report Roofing UnderlaymentsCREEK Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, fH EDITION (2020)
Manufacturer: ATLAS ROOFING CORPORATION Issued October 16, 2020
2000 Riveredge Parkway, Suite 800
Atlanta, GA 30328
(770) 612-6267
www,atlasroofing.com
Quality Assurance: PRI Construction Materials Technologies, LLC (QUA9110)
SCOPE
Category: Roofing
Subcategory: I Underlayments
Code Edition: Florida Building Code, 7' Edition (2017) including High -Velocity Hurricane Zones
(HVHZ)
Code Sections: j 1507.1.1, 1518.4, 1523.1.1, 1523.6.5.2.1
Properties: Physical properties
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST6049)
ATL-033-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (TST6049)
ATL-068-02-01
ASTM D 1970
2015a
ASTM D 4798
2011(2016)
TAS 110
2000
PRI Construction Materials Technologies (TST6049)
ATL-069-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
ATL-149-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
ATL-164-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
ATL-254-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
ATL-255-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
BWR-534-02-01
ASTM D 1970
2015a
ASTM D 4798
2011(2016)
TAS 110
2000
PRI Construction Materials Technologies (TST6049)
BWR-543-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
MBA-004-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
MSA-007-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST6049)
MSA-026-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
WRMI-011-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
MSA-004-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
MSA-007-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST6049)
MSA-026-02-01.1
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
MSA-030-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
MSA-047-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
MSA-054-02-01.1
TAS 103
2020
TAS 110
2000
PRI Construction Materials Technologies (TST6049)
MSA-057-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
MSA-062-02-01.1
ASTM D 1623
2017
PRI Construction Materials Technologies (TST6049)
10SBT0002
TAS 110
2000
PRI Construction Materials Technologies (TST6049)
1085T0007
ASTM D 1623
2017
PRI Construction Materials Technologies (TST6049)
117T11001 '
ASTM D 1623
2017
PRI Construction Materials Technologies (TST6049)
117T0004
TAS 110
2000
PRI Construction Materials Technologies (TST6049)
117T0005
UL 1897
2012
PRI Construction Materials Technologies (TST6049)
1085T0011
ASTM D 1623
2017
i
TAS 103
2020
UL LLC (TST1740)
02-NIC40952
ASTM D 1970
2015a
UL LLC (TST1740)
02-NK40952
ASTM D 226
2009
UL LLC (TST1740)
02-NI(40952
ASTM D 2626
2004(2012)E1
UL LLC (TST1740)
02-NK40952
ASTM D 4869
D
2016
2003
UL LLC (TST1740)
02-NK40952
ASTM 6$80
(2013)E1
ATL14001.7A
FL17�22-R7
Page 1 of 6
This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assur,ince changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, inst Illation, recommended use, or other product attributes that are not
specifically addressed herein.
HCREEK
TECHNICAL SERv10Es, LLC
PRODUCT DESCRIPTION
ATLAS ROOFING CORPORATION
Roofing Underlayments
#15 Specification Felt
ASTM D 226, Type I asphalt saturated organic felt underlayment for use in the
HVHZ.
#30 Organic Saturated Felt
ASTM D 4869, Type Il asphalt saturated organic felt underlayment for use in the
non-HVHZ only.
#30 Specification Felt
ASTM D 226, Type II asphalt saturated organic felt underlayment for use in the
HVHZ and non-HVHZ.
#43 Base Sheet
ASTM D 2626 asphalt saturated and coated, non -perforated, organic felt
underlayment for use in the HVHZ and non-HVHZ.
#90 Mineral Surface Roll
ASTM D 6380, Class M asphalt -saturated organic roll roofing sheet for use in the
Roofing
HVHZ and non-HVHZ.
Gorilla Guard® EVERFELT 30
Asphalt -saturated organic felt underlayment reinforced with glass fiber that meets
the performance requirements of ASTM D 226, Type I for use in the HVHZ.
Slate/Tile Underlayment
ASTM D 6380, Class M asphalt -saturated organic roll roofing sheet for use in the
HVHZ and non-HVHZ.
WeatherMasterO Ice and
ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a
Water 100
fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
WeatherMaster@ Ice and
ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a
Water 200
fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a split -release film, which Is removed during
Installation.
WeatherMasteri) Ice and
ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a
Water 216
fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a split -release film, which is removed during
installation.
WeatherMaster@) Flexible Ice ASTM D 1970 SBS modified, self -adhering underlayment with plastic film surface
and Water for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a
split -release film, which is removed during installation.
WeatherMaster@ Pro -Grade ASTM D 1970, TAS 103, and FRSArrR1 Florida High Wind Concrete and Clay
Ice and Water Tile Installation Manual, Sixth Edition compliant compliant SBS modified, self -
adhering underlayment with a fiberglass mat reinforcement and a poly -fabric
surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered
with a release film, which is removed during Installation.
WeatherMaster@ Tile ASTM D 1970, TAS 103, and FRSA/TRI Florida High Wind Concrete and Clay
Tile Installation Manual, Sixth Edition compliant compliant SBS modified, self -
adhering underlayment with a fiberglass mat reinforcement and a poly -fabric
surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered
with a release film, which is removed during Installation.
ATL14001.7A FL17322-R7 Page 4 of 6
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK ATLAS ROOFING CORPORATION
Roofing Underlayments
TECHNICAL SERVICES, LLC
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation Instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
Exposure of the underlayments shall be limited to a maximum 30 days except as follows:
a) #15 Specification Felt, #30 Specification Felt, and #40 Base Sheet — exposure for greater than 24 hours
may adversely affect product performance
b) WeatherMaster@ Ice and Water 100, WeatherMaster@) Ice and Water 200, WeatherMaster@ Ice and.
Water 216 — maximum 45 days
c) WeatherMaster@ Pro -Grade Ice and Water— maximum 180 days
d) WeatherMasterG Tile — maximum 180 days
Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as
indicated in other current FBC product approval documents):
a) WeatherMaster@ Pro -Grade Ice and Water — DAP Touch 'n Seal Storm Bond Roof Tile Adhesive or
DuPont Tile Bond
b) WeatherMaster@) Tile — DAP Touch 'n Seal Storm Bond Roof Tile Adhesive or DuPont Tile Bond
All ble Roof Coverin sn
owa
h ,y
f
Metal Roof
Composite
Wood
:.
Clay and ! '
_
Asphalt
Panels and
or
Photovoltaic
Shingles
Slate
Concrete..
,Underla ant' ..
1
' Sfifii lles
"..,Shin les
SF in les .
and:Shakes
Shari Ies
The
#16 Specification Felt (HVHZ
Y
Y
N
YZ
Y
N
only)
#30 Organic Saturated Felt
Y
Y
Y
Y
Y
N
#30 Specification Felt
Y
Y
Y
Y
Y
Y
#43 Base Sheet
Y
Y
Y
N
Y
Y
#90 Mineral Surface Roil
Y,
N
N
N
N
Y
Roofing
Gorilla Guard® EVERFELT 30
Y
Y
Y
YZ
Y
N
Slate/Tile Underlayment
Y1
N
N
N
N
Y
WeatherMaster4l) Ice and
Y
Y
Y
N
Y
N
Water 100
WeatherMaster® Ice and
Y
Y
Y
N
Y
N
Water 200
WeatherMasterO Ice and
Y
Y
Y
N
Y
N
Water 216
WeatherMasterlD Flexible Ice
Y
Y
Y
N
Y
N
and Water
weatherMasterel Pro -Grade
Y
Y
Y
N
Y
Y
Ice and Water
WeatherMaster@ Tile
Y
Y
Y
N
Y
Y
Notes: 1) Open valley applications per 1607.2.9.2
2) Wood shingles only
ATL14001.7A FL17322-R7 Page 4 of 6
This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK ATLAS ROOFING CORPORATION
Roofing Underlayments
TECHNICAL Srmwleea, LL.0
WIND RESISTANCE (NON-HVHZ ONLY)
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underlayment System No.1 — WeatherMaster(l Tile only
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: WeatherMaster@ Tile shall be fully adhered to the optionally primed plywood deck.
Maximum Design -62.5 psf
Pressure:
Underlayment System No 2 — WeatherMaster@ Pro -Grade Ice and Water only
Roof Deck: Min. 15/32-inch APA plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: WeatherMaster@ Pro -Grade Ice and Water shall be backnailed 12-inches o.c. to the
plywood deck using min. 129a, 1-1/4" galvanized, ring shank roofing nails with min. 32ga
1-5/8" diameter tin caps.
Maximum Design -105 psf
Pressure:
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Roof slope limitations shall be in accordance with FBC requirements.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Products described within this report may be used as described in other current FBC product approval
documents.
5) Roof coverings shall not be adhered directly to the underiayment unless otherwise approved in this or other
current FBC product approval documents.
6) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
ATL14001.7A FL17322-R7 Page 4 of 6
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
ATLAS ROOFING CORPORATION
Roofing Underlayments
The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building
Code, 7'h Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents
submitted by the named manufacturer.
,,,,,lllnlrr
R=} " 2020.10.16
�� RY . P ,y'ii.
No 74021 _
• • *. UWmNWnaryLd•y�P.•M,1 ..._—...:a�_T..
1.
• =-04'00'
�10 STATE OF •?�1/
'�'•'•;A-� Zachary R. Priest, P.E.
�i,�ss • � R ••'�G % Florida Registration No. 74021
�i ONA\- 1� Organization No. ANE9641
�r1111111110
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest in any other entity Involved in the approval process of the
product.
END OF REPORT
ATL14001.7A FL17322-R7 Page 4 of 6
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
r
RECEIVED
CREEK ATLAS ROOFING CORPORATION
APR 2 2 2022 Roofing Underlayments
TECHNICAL Sr=RVICES, LLG`
St. Lucie County
APPLICATION METHOD Permitting
Fnstallation shall be in accordance with the published manufacturer's Installation Instructions, the PSG, and the
requirements below.
Deck substrates shall be clean, dry, and free from any Irregularities and debris. All fasteners In the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
Exposure of the underlayments shall be limited to a maximum 30 days except as follows:
a) #15 Specification Felt, #30 Specification Felt, and #40 Base Sheet — exposure for greater than 24 hours
may adversely affect product performance
b) WeatherMaster® Ice and Water 100, WeatherMaster@ Ice and Water 200, WeatherMaster® Ice and
Water 216 — maximum 45 days
c) WeatherMasterfal Pro -Grade Ice and Water — maximum 180 days
d) WeatherMaster(ID Tile — maximum 180 days
Self -adhering underlayments may be adhered to primed or unprimed plywood substrates In the non-WHZ.
Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as
Indicated in other current FBC product approval documents):
a) WeatherMaster® Pro -Grade Ice and Water — DAP Touch 'n Seal Storm Bond Roof Tile Adhesive or
DuPont Tile Bond
b) WeatherMaster® Tile — DAP Touch 'n Seal Storm Bond Roof Tile Adhesive or DuPont Tile Bond
runuw+auia Mui wvann a.
Composite
Metal Roof '
or
Wood
Clay and'
Asphalt '
. Panels and .:
Photovoltaic
Shingles
Slate
Concrete
_
Underia ant
Shingles
'Shinled
Shln les
and Shakes'
Shinales.
Tile
#16 Specification Felt (HVHZ
Y
Y
N
Ya
Y
N
only)
830 Organic Saturated Felt
Y
Y
Y
Y
Y
N
#30 Specification Felt
Y
Y
Y
Y
Y
Y
843 Base Sheet
Y
Y
Y
N
Y
Y
#80 Mineral Surface Roll
Yr
N
N
N
N
Y
Roofing
Gorilla Guard® EVERFELT 30
Y
Y
Y
YZ
Y
N
Slate/Tile Undedayment. _
Y'
N
N
N
N
Y
`WeathorMaststO Ice and "
Y
i Y
Y
N
Y
N
Water 100
W
WeatherMaster V Ice and
Y
Y
Y
N
Y
N
Water 200
WeatherMacter® Ice and
y
Y
Y
N
Y
N
Water 216
WeatherMeater0 Flexible Ice
Y
Y
Y
N
Y
N
and Water
Weathemaster® Pro -Grade
Y
Y
Y
N
Y
Y
Ice and Water
WeatherMaster® Tile
Y
Y
Y
N
Y
Y
Notes: 1) Open valley applications per 1ou7.2.e.2
2) Wood shingles only
ZW_0—0. 52—
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC `'�_
FILE COPY
ATL14001.7A FL17322-R7 Page 4 of 6
This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.
RECEIVED
APR 2 2 2022 Ak IRA
St. Lucie County NEMO I etc.
TABLE''1:,ASRH4:r,SHINGLE.CO,MPONENTS .
Type. `
Product
Plant(s)
Material:
Standard
: Description.;",
Berkshire' Hip and Ridge
MN
Shingles with Sealant—,
Hip and : •' '
fiberglass reinforced, hip and ridge
Dur Midge• Hip and Ridge
MN
Ridge - .:
-Shingles•with•Sealant
ASTM D3462
asphalt roof shingles
ProEdge°
GA, CA, OH, OR
-,Shingles =
WeatherGuard' HP Hip and
TN
Ridge Shingles
5.1
5.2
5.3
5.4
5.5
This is a building code evaluation. Neither NEMO ETC, LLC nor Robert N(eminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting
or design guidance unless retained specifically for that purpose.
This Evaluation Report is not for use In FBC High Velocity Hurricane Zone Jurisdictions (i.e., Broward and Miami -
Dade Counties).
This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
Wind.Classification:. Refer.to.Section.6 fo.r.installation requirements to. meet wind classifications
tABLE 2A. WIND,CIASSIFlCATIONSi ASPHALTSHINGLES -
-Product FBC Table 1507.2.7.1 ouR90S.2.6.1 "
Supreme'
Berkshire'
;Duration' Premium'
Duration' Premium
TruDefinition'-Duration' ASTM•D3161(F) & ASTM,D7158(H).
TruDeflnition' Duration' Designer Color Collection
Oakridge'
TruDeflnition' Oakridge'
WeatherGuard' HP
5.5.1 Classification by ASTM D7158:
ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations, Contact the shingle
manufacturer for data specific to each shingle.
NEMO ETC, LLC Evaluation ReportO37940-02-12-Rll
CertljknteofAuthorization 832455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL106741116
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 3 of 10