HomeMy WebLinkAboutBuilding PlanEXTERIOR STUB 17
rol
14TRUSS TOP CHORD
DOOR SECTION - OPEN_
SCALE: N.T.S.
DOOR ELEVATION
SCALE: N.T.S.
M OVERALL DIMENSION
BOTTOM CHORD
12 VERTICAL WEB (TYP)
TRUSS PLAN
SCALE: N.T.S.
INTERIOR STUB
DOOR SECTION CLOSED
SCALE: N.T.S.
He
13 TRUSS WEB (TYP)
jJAMB COLUMN
�I EL KEEPER PLATE FROM JAMB
COLUMN TO DOOR SIDE VERTICAL
TO CAPTURE IN/OUT DISPLACEMENT
IN CLOSED POSITION (TYP)
BUILDING OWNER IS RESPONSIBLE FOR DESIGNING THE
SUPPORTING SLAB/FOOTING, FOR THE BASE PLATE AND
ANCHOR PATTERN SHOWN, AND FOR THE ALLOWABLE
STRESS DESIGN LOADS SHOWN IN NOTES 6 AND 7.
VA
(4) 4"0 x 44' EMBED
HILTI KWIK TZ BOLTS
W8x24
BUILDING WALL
UUT'DIUL
BASE DETAIL
SCALE: N.T.S.
(LEFT SIDE SHOWN
RIGHT SIDE MIRRORED)
MAILRIALS
IYPE_
iA500 GrB
I DESCRIPTION
1
8x2x3 16 HSS
ITOP HORIZONTAL
2
8300# BREAKING STRENGTH
CABLE BRACING
3
CS4x2x065
A570 Gr50 COLD FORM
"C" GIRT
4
CS4x2x065
A570 Gr50_ COLD FORM
"C" GIRT
5
6x2x1 8 HSS
A500 GrB
BOTTOM HORIZONTP
6
1 6x4016_ HSS:_
A500 GrB
INTERIOR VERTICAL
7
8x4x5 16 HSS
A500 GrB
SIDE VERTICAL
8
1 2"4
A1045 ___
A1045
UPPER PIN
9
_1. _
2"0 -
PIVOT PIN
10
W8x24
'A992 ----
JAMB COLUMN
11
-___._._6x2x3L
6 _HSS__.
A500 GrB
TUBE BELOW TRUS`.
12
4x4x1 8 HSS
A500 GrB_
VERTICAL WEB
13
2x2x1 4 ANGLE
A36
TRUSS WEB
14
44 3 16 HSS
A500 GrB
TRUSS TOP CHORD
15
4x4x3 16 HSS
A500 GrB
TRUSS BOTTOM CH
16
4308 HSS
A500 GrB
IA500 GrB
INTERIOR STUB
17
4x3x5/16 HSS
FXTFRIOR STHR
DRAWING IS NOT TO SCALE AND IS FOR FABRICATION
ONLY. DIMENSIONS MAY VARY DUE TO FABRICATOR
TOLERANCES OR PREFERENCES. PRIOR TO ORDERING
AND INSTALLING SHEETING, WINDOWS, DOORS, ETC.,
OWNER AND/OR CONTRACTOR SHALL CONTACT
HIGHER POWER DOORS FOR A TRIM & CUT SHEET.
NOTES:
1. PROJECT LOCATION: PORT ST. LUCIE, FLORIDA.
2. DOOR MAY NOT BE IN AN OPEN POSITION DURING A HIGH WIND
SPEED EVENT (Vult> 115 MPH, 3-SECOND GUST), DOOR MAY NOT
BE OPERATED WITH WIND SPEEDS Vult> 40 MPH (3-SECOND GUST).
3. DOOR DESIGNED AS A COMPONENT/CLADDING, PART 1,
INTERIOR ZONE AND CORNER ZONE.
4. WIND DATA (ALL DATA IS ULTIMATE)
RISK CATEGORY II
WIND EXPOSURE C
4A.Vult (CLOSED POSITION) = 160 MPH
DESIGN WIND PRESSURES: 42.2 PSF, -46.9 PSF
4B.Vult (OPENING POSITION) = 40 MPH
DESIGN WIND PRESSURES: 3.7 PSF, -4.0 PSF
4C.Vult (OPEN POSITION) = 115 MPH
DESIGN WIND PRESSURES: -27.2 PSF
5. OWNER TO PROVIDE SIDING MEETING CODE REQUIREMENTS FOR
DOOR. SECURE TO FRAMING PER CODE, AT 12" MAXIMUM SPACINGS.
6. LATERAL REACTIONS FROM DOOR TO BUILDING (WORKING STRESS)
= 5,500# @ TOP OF COLUMN
= 6,000# @ SLAB
7. VERTICAL REACTION TO THE SLAB = 3,000#
8. DEFLECTION
4" DEFLECTION IN THE OPEN POSITION
4" AS THE DOOR BEGINS TO OPEN
9. DESIGN OF THIS STRUCTURE MEETS THE WIND LOAD
REQUIREMENTS OF THE FLORIDA BUILDING CODE, 7TH EDITION.
DIMENSIONS
B
6'- 10 1 �2 - ------ ---
C
4 SPA. @ 9'-0° = 36'-0"
D 1
3'-5"
D2
LN q - --- -
E
--- ---
L 6'-10"
F
7'-"
4
G
-H1
-
8'-10"
-
9'-10"
12'-10" - —
H2
J
14'-3" -----
15'-9"
17'-3"
49'-9" - - -
--
K
L
M
N
24 SPA. @
R
-
2,_2„ - -
-
S
6, 4„ ---- -
T
15'-0"
R
L
15'-8" _
FILE COPY
HYI)RAULIC DOORS
1400 Territorial Rd. Benton Harbor, M1 49022
(269) 9?7-8990 PH (269) 027-1400 FAX
i
ME
� i
...3
n
:z M �
111 aCa
a
®:®�
<z
co
1%0 IN
w
U
~
&
I—
a
cn
ABBREVIATIONS:
AB
ANCHOR BOLT
MATL
MATERIAL
AFF
ABOVE FINISHED FLOOR
MAX
MAXIMUM
AD1
ADJACENT
MECH
MECHANICAL
ARCH
ARCHITECTURAL
MIN
MINIMUM
BLDG
BUILDING
NTS
NOT TO SCALE
BM
BEAM
O.C.
ON CENTER
BOT
BOTTOM
OPT
OPTIONAL
BRG
BEARING
OSB
ORIENTED STRAND BOARD
CJ
CONTROLJOINT
PLY
PLYWOOD
CL
CENTERLINE
PSI
POUNDS PER SQUARE INCH
CMU
CONCRETE MASONRY UNIT
PSF
POUNDS PER SQUARE FOOT
COL
COLUMN
PT
PRESSURE TREATED
CONC
CONCRETE
REINF
REINFORCEMENT
COND
CONDITION
READ
REQUIRED
CONT
CONTINUOUS
RO
ROUGH OPENING
CONST
CONSTRUCTION
RTU
ROOF TOP UNIT
CLG
CEILING
SCH
SCHEDULE
DEL
DOUBLE
SHTHG
SHEATHING
DIA
DIAMETER
SIM
SIMILAR
DR
DOOR
SMS
SHEET METALSCREWS
DWG
DRAWING
SP
SOUTHERN YELLOW PINE
EA
EACH
SPF
SPRUCE PINE FIR
EI
EXPANSION101NT
STL
STEEL
ELECT
ELECTRICAL
STR
STRUCTURAL
FOR
ENGINEER OF RECORD
SGD
SLIDING GLASS DOOR
EQUIP
EQUIPMENT
SQ
SQUARE
FF
FINISH FLOOR
T&G
TONGUE AND GROOVE
FT
FOOT/FEET
TOB
TOP OF BEARING
GA
GAUGE
TYP
TYPICAL
GC
GENERAL CONTRACTOR
UNO
UNLESS OTHERWISE NOTED
GYP
GYPSUM
VERT
VERTICAL
HGT
HEIGHT
W/
WITH
HORIZ
HORIZONTAL
WIC
WALK IN CLOSET
HB
HOSE BIB
WD
WOOD
INS
INSULATION
WWF
WELDED WIRE FABRIC
KSI
KIPS PER SQUARE INCH
W/O
WITHOUT
MAS
MASONRY
WDW
WINDOW
1.
Y#
3.
4.
S.
6.
Sheet List
____ _.._
Page No
Sheet Name
Sheet Number
1
General Notes
50.1
2
Foundation Plan
SIA
PROJECT COORDINATION
A. THIS DRAWING IS FOR THE FOUNDATION OF A 3,600 SQUARE FOOT, PRE-ENGINEERED METAL BUILDING. SEE THE
FOUNDATION PLAN FOR THE BUILDING INFORMATION.
DESIGN CODE
A. TO THE BEST OF THE DESIGN PROFESSIONALS KNOWLEDGE, THESE DOCUMENTS HAVE BEEN PREPARED WITH AND ARE IN
COMPLIANCE WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE SAFETY STANDARDS AS
DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTERS 553 AND 633 OF THE FLORIDA STATUTES. THESE
DOCUMENTS MEET OR EXCEED THE REQUIREMENTS OF:
a. 2020 FLORIDA BUILDING CODE, SEVENTH EDITION, BUILDING, FBC..
b. 2020 FLORIDA BUILDING CODE, SEVENTH EDITION, RESIDENTIAL, FBC-R.
DESIGN CRITERIA
A. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE (ACI) 318 AND 332,
B. REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ACI 318.
DESIGN LOADS
A. ROOF DEAD LOAD (SUPERIMPOSED):
a. TOP CHORD (ROOF) 3 PSF (METAL)
B. ROOF LIVE LOAD: 20 PSF
C. FLOOR LOADING:
a. DEAD LOAD 125 PSF
b. LIVE LOAD 150 PSF
D. DOOR LOADS (HIGHER POWER HYDRAULIC DOORS 50'-0"x15'-8.5")
a. BELOW LOADS ARE APPLIED TO JAMBS AT LOCATIONS 4B AND 4E
b. 6 KIPS LATERAL
C. 3 KIPS VERTICAL
STRUCTURE SPECIFICATION
A. BUILDING OCCUPANCY CATEGORY: II
B. CONSTRUCTION TYPE: V-S
C. OCCUPANCY CLASSIFICATION: R-3
D. WIND SPEED
a, ULTIMATE (LRFD) = 160 MPH
b. ALLOWABLE (ASD) = 124 MPH
E. WIND EXPOSURE CATEGORY: C
F. ENCLOSURE CLASSIFICATION: ENCLOSED
G. INTERNAL PRESSURE COEFFICIENT: +/-0.18
H. WIND-BORNE DEBRIS AREA: YES
I. REFER TO DRAWINGS FOR STRUCTURE HEIGHT AN DAREA
1. STRUCTURAL LOADS AND DESIGN PRESSURES LISTED IN THESE PLANS ARE ALLOWABLE (ASD) UNLESS NOTED OTHERWISE.
PROJECT REQUIREMENTS:
A. THESE PLANS SHALL REMAIN ON THE PROJECT AT ALL TIMES.
B. THE CONTRACTOR AND SUB -CONTRACTORS SHALL STRICTLY ADHERE TO ALL APPLICABLE CODES DURING THE COURSE OF
CONSTRUCTION, INCLUDING ALLSTATE, CITY AND COUNTY BUILDING, ZONING, ELECTRICAL, MECHANICAL, PLUMBING AND
FIRE CODES, AS WELLASANY APPLICABLE HOMEOWNER ASSOCIATION REQUIREMENTS.
C. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND SHALL NOTIFY THE DESIGN PROFESSIONAL OF RECORD OF
ANY DISCREPANCIES OR CONFLICT W ITH APPLICABLE CODES PRIOR TO CONSTRUCTION.
D. THE ARCHITECT/ ENGINEER SHALL NOT BE RESPONSIBLE FOR SAFETY PROCEDURES, THE MEANS AND METHODS OF
CONSTRUCTION, TECHNOLOGIES OR THE FAILURE OF THE CONTRACTOR TO COMPLETE THE WORK IN ACCORDANCE WITH
DRAWINGS, SPECIFICATIONS OR THE RELATED CODES.
E. THE CONTRACTOR SHALL FULLY REVIEW ALL ITEMS CONTAINED IN THE DRAWINGS AND SHALL COORDINATE ALL DIMENSIONS,
LOCATE DEPRESSED SLABS, SLOPES, DRAINS, OUTLETS, RECESSES, EMBEDS, SLEEVES, ETC.
F. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE ERECTION PROCEDURES AND SEQUENCING. THE GENERAL
CONTRACTOR IS RESPONSIBLE FOR HIRING A DESIGN PROFESSIONAL FORTEMPORARY SHORING OR LIFTING PROGRAMS.
G. NOTES, DETAILS, AND SECTIONS ON THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW
GENERAL REQUIREMENTS THROUGHOUT. "TYPICAL" DETAILS SIMPLY REFER TO ALL CONDITIONS TREATED SIMILARLY.
CONTRACTOR SHALL MAKE MINOR MODIFICATIONS TO ACCOMMODATE MINOR SIMILAR VARIATIONS.
H. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES OR MODIFICATIONS WITHOUT EXPRESSED WRITTEN APPROVAL OF
THE ENGINEER OF RECORD IN ADVANCE.
1. FOLLOW LIFT MANUFACTURER RECOMMENDATION FOR ADDITIONAL REQUIREMENTS AT PROPOSED LIFT LOCATIONS.
SITE WORK:
1. SOIL
A. ALL WORK SHALL CONFORM TO THE FINAL GEOTECHNICAL REPORTAND THE FINAL GRADING PLAN ACCEPTED BY THE
AUTHORITY HAVING JURISDICTION.
B. IF THE SOILS REPORT IS NOT AVAILABLE, SOIL BEARING CAPACITY IS ASSUMED TO BE A MINIMUM OF 1,800 PST.
C. CONTRACTOR SHALL VERIFY COMPACTION REQUIREMENTS PRIOR TO THE EXECUTION OF WORK. DISCREPANCIES SHALL BE
BROUGHT TO THE ATTENTION OF THE DESIGN PROFESSIONAL PRIOR TO COMMENCEMENT OF WORK.
D. FOOTINGS SHALL BE PLACED ON UNDISTURBED SOIL OR COMPACTED FILL, FREE OR ORGANIC MATTER AND COMPACTED TO
95% OF THE MODIFIED PROCTOR, UNLESS OTHERWISE NOTED IN THE GEOTECHNICAL REPORT.
E. THE SOILS WITHIN 15 FEET OF THE PROPOSED BUILDING PAD SHALL BE FREE OF ANY WOOD, VEGETATION. STUMPS,
CARDBOARD, TRASH, OR OTHER DELETERIOUS MATERIAL.
F. WATER MANAGEMENTAT THE PERIMETER SHALL BE MAINTAINED AND SHALL INCLUDE:
a. CONDENSATE DRAINS AND ROOF DOWN SPOUTS SHALL DISCHARGE AT LEAST 12" FROM BUILDING.
b. IRRIGATION / SPRINKLER SYSTEMS, INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN 16"
OF BUILDING.
C. LANDSCAPE SHALL BE INSTALLED AT LEAST 24" AWAY FROM BUILDING PERIMETER,
G. ANY FILL BROUGHT TO THE SITE SHALL MEET PROJECT REQUIREMENTS OF THE GEOTECHNICAL ENGINEER.
2. SOIL TREATMENT
A. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES BAITING
SYSTEMS, AND/OR PESTICIDES APPLIED TO WOOD OR OTHER APPROVED METHODS.
B. BOXED AREAS IN CONCRETE FLOORS FOR INSTALLATION OF TRAPS, ETC. SHALL BE MADE WITH PERMANENT METAL OR
APPROVED PLASTIC FORMS. FORMS SHALL BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL AFTER
INITIAL TREATMENT.
C. PROVIDE VAPOR BARRIER IMMEDIATELY FOLLOWING SOILTREATMENT.
D. A LICENSED PEST CONTROL COMPANY SHALL SUBMIT CERTIFICATE OF COMPLIANCE TO THE BUILDING DEPARTMENTAT
COMPLETION OF TREATMENT.
E. AFTER COMPLETION OF WORK, ALL LOOSE WOOD, CONSTRUCTION DEBRIS, AND ORGANIC MATERIAL SHALL BE REMOVED
FROM WITHIN 16" OF BUILDING PERIMETER.
CONCRETE:
1. MATERIALS
A. ALL WORK SHALL BE MIXED, PLACED, AND CURED IN ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE ACI 318.
B. CONCRETE SHALL HAVE THE FOLLOWING SPECIFICATIONS UNLESS NOTED OTHERWISE:
AREA STRENGTH (PSI) SLUMP AGGREGATE SIZE
SLAB 3,000 PSI (28 DAYS) 4"-6" 3/4" - 2"
FOOTER 3,GW PSI (29 DAYS) V-6" 3/4" - 2"
C. GENERAL CONTRACTOR SHALL SUBMIT MIX DESIGN TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO
PLACING ANY CONCRETE.
D. MATERIAL FOR CONCRETE SHALL CONFORM TO THE FOLLOWING:
a. PORTLAND CEMENT-ASTM C150
b. AGGREGATES: COURSE AGGREGATE: ASTM C33, LIGHTWEIGHT: ASTM C330, FINE: ASTM C33
E. WATER SHALL BE FREE OF CONTAMINANTS, CLEAN AND POTABLE.
F. WATER SHALL NOT BE ADDED TO THE MIX ONSITE UNLESS SPECIFICALLY APPROVED IN THE MIX DESIGN SPECIFICATIONS PER
THE SPECIFIED VOLUME.
G. ADMIXTURES SHALL CONFORM TO THE MIX DESIGN.
2. TESTING AND SAMPLING
A. ALL TESTING SHALL BE DONE BY AN INDEPENDENT TESTING LABORATORY IN ACCORDANCE WITH ASTM REQUIREMENTS. TEST
REPORTS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO FURTHER CONSTRUCTION.
B. THREE CYLINDER TEST SAMPLES SHALL BE MADE DURING EACH DAYS SEQUENCE PER EVERY 50 YARDS. TWO SLUMP TESTS (PER
ASTM C143) SHALL BE PERFORMED AND RECORDED FOR EACH BATCH, ONE AT THE BEGINNING AND ONE ATTHE END.
a. ONE CYLINDER SHALL BE BROKEN AT 7 DAYS AND ONE AT 28 DAYS. RESERVE CYLINDER WILL BE NEEDED IF SECOND
TEST FAILS SPECIFICATIONS.
C. SUBMIT TEST RESULTS TO ENGINEER OF RECORD WITHIN FIVE DAYS OF RESULTS.
3. REINFORCING
A. REINFORCING SHALL HAVE GRADE IDENTIFICATION MARKS AND SHALL CONFORM TO ASTM A615, GRADE 60.
B. REINFORCING SHALL BE FREE OF RUST, SCALE OR OTHER BOND REDUCING COATINGS.
C. REINFORCING SHALL BE PLACED IN CONCRETE TO PROVIDE MINIMUM COVERAGE IN ACCORDANCE WITH ACI 318 OR AS
INDICATED IN THE DRAWINGS.
a. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH - 3"
b. CONCRETE EXPOSED TO EARTH OR WEATHER - 1.5"
C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND - 3/4"
D. MINIMUM LAP SPLICE (UNLESS NOTED OTHERWISE)
BAR SIZE MASONRY CONCRETE
1500 PSI 2000 PSI 3000 PSI 4000 -5000 PSI
#4 24" 2V. 27" 15"
#5 30" 26" 21" 19"
#6 36" 31" 26". 22"
#7 42" 46" 37" 32"
#8 48" 53" 43" 37"
E. ACCURATELY PLACE AND SUPPORT REINFORCING WITH CHAIRS, BAR SUPPORTS, SPACERS, OR HANGERS AS RECOMMENDED
BY ACI DETAILING MANUAL.
F. PLACE (1) ONE ACI STANDARD LAP SPLICE BAR, OF THE SAME SIZE AS FOUNDATION REINFORCING, LOCATED AT THE OUTSIDE
BAR OF FOUNDATION CORNERS.
G. ENGINEER ASSUMES NO RESPONSIBILTY FOR EXPANSION/CONTRACTION CRACKS THAT MAY APPEAR IN CONCRETE SLABS. THE
USE OF WELDED WIRE MESH AND/OR FIBER MESH WILL GREATLY REDUCE RISK OF THESE TYPES OF CRACKS. THE USE OF
DIAGONAL STEELAT RE-ENTRANT CORNERS IS HIGHLY RECOMMENDED BUT NOT REQUIRED UNLESS NOTED ON THE
FODUNDATION PLAN. SLAB CRACKS ARE TYPICALLY EXPECTED AND PREVENTATIVE MEASURES SHALL BE TAKEN TO
ISOLATE/CONTROL AND CRACKS THAT MAY AFFECT ARCHITECTURAL FINISHES.
H. WELDED WIRE MESH, IF USED, SHALL BE IN ACCORDANCE WITH ASTM A85 AND SHALL BE 6x6-W1.4xW1.4, UNLESS NOTED
OTHERWISE ON DRAWINGS.
a. INSTALL WELDED WIRE MESH IN THE MIDDLE OF THE SLAB AND SUPPORT WITH APPROVED MATERIALS OR
SUPPORTS AT SPACING NOT TO EXCEED THREE FEET ON CENTER OR IN ACCORDANCE WITH THE MANUFACTURERS
SPECIFICATION.
b. LAP ALL JOINTS IN WELDED WIRE MESH 12 INCHES.
1. FIBER MESH, IF USED IN LIEU OF WELDED WIRE MESH SHALL BE 2A LBS PER CUBIC YARD UNLESS NOTED OTHERWISE.
4. PLACEMENT AND FINISHING
A. ALL CONCRETE PLACED UNDER ROOF PROTECTION SHALL BE PLACED OVER 6 MIL MIN. POLYETHYLENE VAPOR BARRIER,
LAPPED 81NCHES MINIMUM WITH ALL SEAMS TAPED UNLESS NOTED OTHERWISE.
B. PLACE ALL EMBEDDED ITEMS (ANCHOR BOLTS, DOWELS, ETC.) IMMEDIATELY PRIOR TO PLACEMENT OF CONCRETE OR DURING
CONCRETE OPERATIONS.
C. PROTECT ALL CONCRETE FROM DAMAGE AFTER PLACEMENT.
D. CONCRETE SHALL BE PLACED WITHIN 90 MINUTES OF BATCHING UNLESS MIX DESIGN SPECIFIES OTHERWISE.
E. CONCRETE SHALL BE PLACED WITHIN THE SLUMP LIMITS SPECIFIED IN THE DESIGN MIX.
F. WATER ADDED ATTHE SITE SHALL BE KEPT TO A MINIMUM AND WITHIN THE SPECIFIED SLUMP. RUN MIXER FOR THIRTY
REVOLUTIONS AT 8-12 RPM FOLLOWING THE ADDITION OF WATER ATTHE SITE.
G. CONCRETE SHALL NOT BE PLACED DURING RAIN. FOLLOWING PLACEMENT OF CONCRETE, PROTECT FROM RAIN PRIOR TO
INITIAL SET.
H. PLACEMENT SHALL BE CONTINUOUS UNTIL ALL WORK IS COMPLETED.
I. DO NO USE CONTAMINATED, DETERIORATED, OR RETEMPERED CONCRETE.
1. THOROUGHLY WORK CONCRETE AROUND REINFORCING BARS.
K. PLACE CONCRETE TO GRADES AND ELEVATIONS REQUIRED FOR PROJECT.
L. REMOVE ALL GRADE STAKES AFTER PLACEMENT OF CONCRETE.
M. AT SLABS GREATER THAN 20 FEET IN ANY DIRECTION
a. PROVIDE SAW CUT CONTROL JOINTS IN CONCRETE AFTER INITIAL SET AND PRIOR TO HARDENING
b. SAWCUTJOINTS SHALL BE 113 THE DEPTH OF THE SLAB.
C. ANY SLAB EXCEEDING 20 FEETSHALL BE DIVIDED AT ALL CORNERS AND SHALL EXTEND IN EACH 90 DEGREE
DIRECTION.
N. PROVIDE SURFACE FINISH REQUIRED FOR INTENDED FINAL APPLICATION.
0. SILL PLATE ANCHORS SHALL BE AS SPECIFIED IN SPECIFICATIONS.
P. CONSOLIDATE CONCRETE THOROUGHLY DURING CONCRETE OPERATIONS.
Q. CURE CONCRETE FOR THREE DAYS TO MINIMIZE SHRINKAGE CRACKS.
METAL AND STEEL BUILDING CONSTRUCTION:
1. GENERAL
A. METAL BUILDING ERECTOR SHALL BE RESPONSIBLE FOR ERECTION OF THE STEEL AND ASSOCIATED WORK IN COMPLIANCE WITH THE
METAL BUILDING MANUFACTURERS ASSOCIATION.
B. THE BUILDER IS RESPONSIBLE FOR DESIGNING, SUPPLYING, LOCATING AND INSTALLING TEMPORARY SUPPORTS AND BRACING DURING
ERECTION OF THE BUILDING. METAL BUILDING BRACING IS DESIGNED FOR CODE REQUIRED LOADS AFTER BUILDING COMPLETION AND
SHALL NOT BE CONSIDERED AS ADEQUATE ERECTION BRACING.
C. TENSION BRACE RODS WORK IN PAIRS TO BALANCE FORCES CAUSED BY INITIAL TENSIONING. CARE MUST BE TAKEN WHILE TIGHTENING
BRACE RODS SO AS NOTTO CAUSE ACCIDENTAL OR MISALIGNMENT OF COMPONENTS. ALL RODS MUST BE INSTALLED LOOSE AND
THEN TIGHTENED. RODS SHALL NOT EXHIBIT EXCESSIVE SAG. FOR LONG OR HEAVY RODS OR ANGLES, IT MAY BE NECESSARY TO
SUPPORT THE ROD AT MID -BAY BY SUSPENDING IT FROM A SECONDARY MEMBER.
D. EQUIPMENT BRACING AND SUSPENSION CONNECTIONS MUST NOT IMPOSE TORSION OR MINOR AXIS LOADS, OR CAUSE LOCAL
DISTORTION IN ANY STRUCTURAL COMPONENTS.
E. ALL FIELD WELDING MUST BE DONE AT THE DIRECTION OF A DESIGN PROFESSIONAL, AND DONE IN ACCORDANCE WITH AWS
(AMERICIAN WELDING SOCIETY) BY WELDERS QUALIFIED TO PERFORM THE WORK AS DIRECTED BY THE APPLICABLE WELDING
PROCEDURE SPECIFICATION (WPS). A WPS SHALL BE PREPARED BYTHE CONTRACTOR FOR EACH WELDING VARIATION SPECIFIED. THE
CONTRACTOR IS RESPONSIBLE FOR ANY SPECIAL WELDING INSPECTIONS AS REQUIRED BY LOCAL JURISDICTION.
2. MATERIALS
A. ALL STRUCTURAL PLATES, CHANNELS AND MISCELLANEOUS METALS SHALL BE IN ACCORDANCE WITH ASTM SPECIFICATION BELOW OR
PER METAL BUILDING MANUFACTURER.
MATERIAL ASTM DESCRIPTION YEILD STRENGTH
STRUCTURAL STEEL PLATE A529/ A572 / A1011 50 KSI
HOLLOW STRUCTURAL A500 42 KSI
HOT ROLLED STR. SHAPES A500 / A572 / A592 / A992 50 KSI
HOT ROLLED ANGLES A36 36 KSI
COLD FORMED SHAPES A653 / A1011
ROOF AND WALL SHEETING A653 / A792
BOLTS A3007 / A325
RODS A572 / A108
ANCHOR RODS F1554 36 KSI
B. ALL STEEL EXPOSED TO WEATHER SHALL BE GALVANIZED.
C. ALL ANCHOR BOLTS AND THREADED RODS SHALL BE A MINIMUM GRADE A.
D. STRUCTURAL EPDXY SHALL BE HILT] HIT-HY 200 OR EQUAL, UNLESS NOTED OTHERWISE.
E. WELD FILLER MATERIAL SHALL BE 70 KSI TENSILE STRENGTH.
3. EXECUTION
A. INSTALL METALS AS DETAILED ON METAL BUILDING DRAWINGS AND PERMIT DRAWINGS.
B. STEELWORK SHALL CONFORM TO THE LATEST EDITION OF THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR
BUILDING AS ADOPTED BY THE AISC AND METAL BUILDING MANUFACTURERS ASSOCATION.
C. ALL STEEL SHALL BE PAINTED WITH ONE COAT OF RED OXIDE PRIMER AND SHALL BE TOUCHED UP AFTER INSTALLATION, UNLESS THE
MATERIAL IS STAINLESS STEEL.
D. ALL DRILLED AND EPDXIED HOLES SHALL BE PROPERLY CLEANED AND VERIFIED BEFORE INSTALLATION OF EPDXY ORANCHORS.
DOORS AND WINDOWS
1. GENERAL
A. THE DESIGN PRESSURES FOR THE DOORS AND WINDOWS SHALL BE NOT LESS THAN THE VALUES SHOWN IN THE SCHEDULE OR
PLAN. THESE DESIGN PRESSURES ARE LISTED IN ALLOWABLE (ASD) WIND PRESSURES.
B. ALL EGRESS WINDOWS SHALL MEET FBC SECTION 1029 OR FBC-R 310, AS APPLICABLE.
C. GLAZING IN HAZARDOUS LOCATIONS SHALL COMPLY WITH FBC-R 305.
D. OPENINGS FROM A PRIVATE GARAGE TO RESIDENCE SHALL MEET FBC-R 302.5.1.
E. SHUTTERS (IF INSTALLED) SHALL MEET FBC-R 301.2.1.2.
F. OPENING NOTATIONS
a. WIDTH (FEET INCHES)x HEIGHT (FEET INCHES). EXAMPLE: 21068 = T-10" WIDE x 6-8"TALL
b. TWIN OR DOUBLES: EXAMPLE 12) 3050 = TWO T-0" WIDE x T-0" TALL WINDOWS MULLED TOGETHER
2. MATERIALS
A. THE EXTERIOR DOORS AND WINDOWS SHALL BE INSTALLED IN STRICT COMPUANCE WITH THE MANUFACTURER'S NOTICE OF
APPROVAL (MIAMI NOA OR FBC APPROVAL).
B. THE EXTERIOR DOORS AND WINDOWS MUST WITHSTAND THE IMPACT OF WIND BORNE MISSILES, OR SHALL BE PROTECTED
WITH AN APPROVED IMPACT RESISTANT COVERING.
C. EACH UNIT SHALL BEAR A LABEL WITH THE MANUFACTURER'S NAME AND DESIGN PRESSURES, WHICH SHALL REMAIN UNTIL
FINAL INSPECTION IS PASSED BY LOCAL AUTHORITY HAVING JURISDICTION.
D. ALL FENESTRATIONS (WINDOWS, DOORS, AND GLAZED BLOCK) SHALL COMPLY WITH THE FOLLOWING U FACTORS AND
S.H.G.C. (FBC-EC R402.3) OR PROVIDE A PERFORMANCE BASED ENERGY CODE (FBC E400.3).
a. IMPACTGLAZING: UFACTOR =0.65 MAXIMUM AND S.H.G.C=0.25 MAXIMUM
b. NON -IMPACT GLAZING: U FACTOR = 0.40 MAXIMUM AND S.H.G.0 = 0.25 MAXIMUM
E. SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. FLUID APPLIED MEMBRANES SHALL MEET
AAMA 714. THE FLASHING SHALL EXTEND PAST THE SURFACE OF THE EXTERIOR WALL FINISH. ALL LISTED PRODUCTS BELOW
ARE APPROVED ALONG WITH ADDITIONAL PRODUCTS THAT MEET OR EXCEED THEIR PERFORMANCE SPECIFICATIONS.
a. LIQUID FLASHING: OSI QUAD FLASH, PROTECTOWRAP LWM200, OR TREMCO DYMONIC 100.
3. EXECUTION
A. PRIOR TO INSTALLATION, ALL FRAMES AND BUCKS SHALL BE CHECKED FOR RACK, TWIST, AND OUT OF SQUARE.
B. FOLLOW FMA (FENESTRATION MANUFACTURERS ASSOCIATION) GUIDELINES FOR FLASHING ALL OPENINGS.
a. CAULK ALL INSIDE CORNERS OF OPENINGS WITH AN APPROVED SEALANT.
b. APPLY AN APPROVED FLASHING TO ALL FOUR SIDES OF OPENINGS.
C. APPLY A HEAVY, UNINTERRUPTED BEAD OF APPROVED SEALANT TO THE BUCKS PRIOR TO ATTACHING TO THE
OPENING PER WINDOW / DOOR DETAILS.
d. SEAL BUCKS WITH AN APPROVED FLASHING MATERIAL.
e. INSTALL DOOR / WINDOW AND APPLY BEAD OF APPROVED SEALANT AROUND PERIMETER.
C. APPROVED CORROSION RESISTANT FLASHING SHALL BE APPLIED IN SHINGLE FASHION IN A MANNER TO PREVENT ENTRY OR
PENETRATION OF WATER TO THE BUILDINGS STRUCTURAL FRAMING COMPONENTS.
D. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH.
1/8' WIDE SAW -CUT SHALL BE MADE AS
SOON AS CONCRETE HAS HARDENED
SUFFICIENTLY TO PREVENT AGGREGATE
BEING DISLODGED BY SAW
Saw 0
-ooTing
3/4" = V-0"
SEE PLAN
18'4'
SEE METAL BUILDING DRAWINGS FOR ROOF,
WALLS, COLUMNS AND DETAILS.
COMPONENTS SHOWN ON HERE FOR
CONCEPT ONLY
OPTIONAL RECESS AT DOOR OPENINGS
ANCHORS PER METAL BLDG. MANUF. AT
BASE ANGLE
SLOPE GRADE AWAY FROM FOUNDATION,
COMPACT 24" OUTSIDE OF BLDG MIN.
3 Typical Wall Section Metal
so
L
0'-3'
COY.
BACKER ROD
WITH SEALANT
CONCRETE SLAB
PER PLAN
t/3 t
Joint Detail T
I�
PROVIDE ADDITIONAL#5 BARS
AT THICKEND FOOTING A MIN. 1' - 4"
OF 12" BELOW PIPE MIN.
12
1
IT-8 1/16" Ht.
CLEAR
#5 BAR HOOKED AROUND COLUMN BOLTS, LOCATE PER
FOUNDATION PLAN, TYP.
CONCRETE SLAB PER FOUNDATION PLAN
6 MIL VISQUEEN VAPOR BARRIER OVER
TERMITE TREATED, WELL COMPACTED FILL
REINFORCED CONC. FOOTER PER
PLAN/SCHEDULE
FF
EQUIPMENT/BUILDING PAD
1/2" COMPRESSIBLE JOINT FILLER
CONCRETE FOOTER
PER PLAN
Digitally sigr
Te re n ce by Terence
SChlitt
I i tt Date: 2022.0
S c h
15:30:40 -04
F.
0
Project Number:
22L001
al
O
o�
N
o
N
N
0
O
`U
Q)
E
O
U
N
0
_0
Z
o
N
a
N
(.
r
n
LLI
CD
d
W
Q
CO
UJ
-
N
L
�
N
MATTHEW
7:4-29 24-29
®
17
J
z
co
m
0
LU
>
W
0
w
m O
F-w
z
U Z
�
Ol
> M m w
w
N
v z
N
m=o L7
■
W
W
It
d
W N
W
Q
U
m Co�
^
■
z 0 u
L
1
O > w
0
Z
O
z
ul Z
L4
N
' U?y �
o LL O°o
hoZ N
N O
°w - i-
w`"""0 m
N Q 0 Z-
i Z
O`,,`\,
a
W� V D
c
Ea a o c
e a" o w v w
Y.o
1
General Notes
N
0
`3 0
N
cri
N
N
O
❑ F lj i'7 I N
\ N
a