Loading...
HomeMy WebLinkAboutCertification For Design Load Compliance_J4-7 2ZoI — RU�Planning & Development Services Department c c:� Building & code Regulations Division 2300 Virginia Ave, Fort Pierce, FL 34982 V - ®._ _. ' -. a • -.... (772)-462-1577 Certification for Design Load Compliance 7th Edition Project Name: McGrath Residence Project Address: 18706 Mach One Dr., Fort Pierce, FL 34987 Permit#: Occupancy Type: II Construction Type:V-B INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • If submitting hard copy, submit (2) copies with all pertinent information. St Lucie Fire District requires a digitally signed electronic version. • If submitting electronically, form should be uploaded into Bluebeam. Separate submission to Fire is still required • All digital files must be in an unlocked Portable Document Format (PDF) version * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 7th Edition using ASCE 7-16 2. Structure Designed as (check one): Enclosed Partially Enclosed X Open 3. Risk Category: I X II III IV Exposure Category: B X C D 4. Design Wind Velocity mph 124 ASD 160 LRFD End Zone Width: 7 ft 5. Mean Roof Height 21 ft Roof Pitch: 1 :12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: See Metal Building Plans Zone 4: +31 -34 Zone 5: +31 -40 Garage: +31 -40 6a. Roofs Maximum +/- pressures: + +14.2 psf. - 100.2 psf. Or define individual zones on the plans 7. Design Loads: Floor:150 PSF Roof-Dead:1 PSF Roof-Live:20 Balcony+/-n a PSF Dock: n a PSF Deck: n/a PSF Stairs: n a PSF Fence: n a PSF Railings: n a PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Please Explain: The metal building manufacturer engineer is responsible for the building 9. Is a Continuous Load Path Provided? Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 1800 PSF Soil Test Reports Submitted? Yes No Assumed DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I Frityf,that, to the best of my knowledge and belief, the attached plans & specifications have been designed to rJ�cd Il�t�e applicable structural portions of the current Florida Building Code as adopted. ��'•'cENSF',''A Terence Schlitt, PE 81238 CA# 32295 . � No �2Styre, ba*,�dSea l Print Name Cert # & Co. CertofAuthorization * W TE Schlitt Engineering STATE OF 1555 Indian River Blvd B-145 Vero Beach, FL 32960 �. •,,��A€'d��b� f,/� /Z Company Name & Address I I