Loading...
HomeMy WebLinkAboutProduct Approval Roof DecFlorida Building Code Online Page 1 of 2 ,..,F-s Cri0hC 74RRtEKtiQF.. �%a y,�s. }� Er ..� �-C zrx �,ac +%� Rs .e --s -vim "s`t•* II '' ` uxaa.. n€.rc,s.:,ae*•., xn, ,...n...�Z s�.'..rmrox�.3.�..mSx: � �r, ��F.�� _ .t......_ . �. � .... , ....� te T • •� Product Approval USER: Public User s. ApprovalProduct Application Type New Code Version 2020 Application Status Approved Comments '.i}FSEFIEE.Q �r;.l Product Manufacturer Crane Composites, Inc Address/Phone/Email 8015 Dixon Drive Florence, KY 41042 (859) 283-6136 abarry@cranecomposites.com Authorized Signature Allison Barry abarry@cranecomposites.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Structural Components Subcategory Roof Deck Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer El Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Bala Sockalingam the Evaluation Report Florida License PE-62240 Quality Assurance Entity Farabaugh Engineering and Testing, Inc Quality Assurance Contract Expiration Date 09/30/2024 Validated By Yoosef Lavi, P.E. 2 Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL38459 RO COI CertificateIndeoendence odf Standard Year ASTM D1929 2016 ASTM D635 2014 ASTM E84 2016 FM 4470 2016 UL 580 2006 https://floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsBkU5zAW6hSxG... 4/ 19/2022 Florida Building Code Online Page 2 of 2 ' it Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 04/17/2021 04/19/2021 04/26/2021 06/09/2021 FL # Model, Number or Name Description 38459.1 Duralite High Strength R-Panel Fiber reinforced plastic (FRP) roof panel Limits of Use Installation Instructions Approved for use in HVHZ: No FL38459 RO II Crane Installation Guide 25 May 2010.odf Verified By: Andy Wermeling Kentucky PE Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: No Design Pressure: +41.6/-41.6 Evaluation Reports Other: Inward and outward load of 41.6 psf at support FL38459 RO AE Eva luationReoortC2440 2.Ddf spacing of 60" D.C. Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: —M W ® N Credit Card https://floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsBkU5zAW6hSxG... 4/19/2022 ME A 390C I, IN W4 W i " -�;' k "i 1 5 Mq_ e - - wrl� w�ff-maiii-M."� tal"i. i� IN.. ION GUIDE .... ..... r LITE HIGH STRENGTH R-PANEL (Tool #162) DISCLAIMERS (Please read) PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION These guidelines are provided in good faith to help prevent installation problems caused by common errors. The manufacturer and/or distributor of the product bears no responsibility for installation actions taken or not taken. There are many nuances of installation that are assumed to be general construction knowledge to an experienced installer; such nuances are not included in these instructions. Rather, these installation guidelines are strictly recommendations and are not intended to serve as a step-by-step, foolproof installation checklist. Selection of an experienced frp installer is the sole responsibility of the project owner and architect. Crane Composites does not accept any responsibility forjob failure resulting from or associated with improperjob site environmental conditions. :The instructiions' provided in:.this document are applicable for:�nstailab'dn'of both roofs; and walls.. www.frp.com 1 1.800.435.0080 1 1.815.467.8666 (fax) I salesbp@cranecomposites.com _ CRANE Composites Crane Composites is the maker of Glasbord, Sequentia. Sanigdd II and a variety of other fiberglass reinforced plastic (frp) composite wall panels. Inspired by y P the Kemlite tradition, Crane Composites has over 50 years of experience in commercial building products and is a recognized industry leader in frp applications. A crane Ca Company Form 3900 1 Rev. 0 13.10 1 (5434) Duralite is a registered trademark of Crane Composites, Inc. CRANE Composites Duralite High Strength R-Panel I Installation Guide 37.75 in 36.00 in 12.00 in in 1.00 in N 4.00 in 4.00 in 1.00 in 1.38 in 4----I 0 3.06 in 3900 Rev. 0 13.10 C RA N E Composites DRAWN DATE BY RCK 1/18/10 SCALE N.T.S. DWG. R PANEL 162 PANEL PROFILE REV. 0 C.E.R. NA R-Panel I Profile Tool #162 Purlin Fasteners With Washers: #12-14 x 1" self -tapping screws with corrosion resistant coating and 1 %8" stainless steel washer backer with an EPDM gasket. Side Lap Fasteners: #6 x 1'/" stainless steel grommet with hex head machine screw and neoprene sleeve. MCRANEComposites Duralite High Strength R-Panel I Installation Guide Figure 1: Tape Sealer Placement — Lower Panel 3900 Rev. 0 13.10 Apply tape sealer to lower panel: apply along peak of major ribs (2) for side laps and across panel width at downslope for sealing end lap. CRANE Composites 3900 Duralite High Strength R-Panel I Installation Guide Rev. 0 13.10 DPE IN & MIDSPAN PURLIN PURLIN 3 1/2" O.C. Figure 2: Fasten Light Transmitting Panel to Purlins Fasten light transmitting panel to the purlin at the downslope end and to the intermediate purlin. For each purlin, use 9 Purlin fasteners with washers. See Figure 3 for fastening detail and Figure 4 for fastener spacing. 'M! CRAN E Composites 3900 Duralite High Strength R-Panel I Installation Guide Rev. 0 13.10 PyErSTSIM 1.00 LIGHT TRANSMITTING FRP PURLIN Figure 3: Fastening Detail for End lap at Downslope PURLIN FASTENER %SHER TAPE SEALER 3/16" X 1" w. CRANE Composites Duralite High Strength R-Panel I Installation Guide 3.50 in TYP. 5.00 in TYP. 3.50 in TYP. Figure 4: Fastener Spacing for Fastening to Purlins 3900 Rev. 0 13.10 aCRANE Composites Duralite High Strength R-Panel I Installation Guide 3900 Rev. 0 13.10 IN PE J Q PURLIN �v Figure 5: Install Upper Metal Panel and Fasten Side Laps Make certain sealer tape has been applied for the side laps and for the end lap at the upslope. Fasten side laps with panel side lap fasteners 10" on center. Fasten end lap at upslope with 9 Purlin Fasteners See Figure 6 for fastening detail and Figure 4 for fastener spacing. 0 CRANE Composites Duralite High Strength R-Panel I Installation Guide UPPER ROOF PANEL FAMATAIM 1.00 PURLIN FASTENER HASHER 3900 Rev. 0 13.10 `mod TAPE SEALER 3/16" X 1" LIGHT TRANSMITTING FRP PURLIN Figure 6: Fastening Detail for End Lap at Upslope R r� CRANE Composites Duralite High Strength R-Panel I Installation Guide 3900 Rev. 0 13.10 Any questions about installation can be directed to: Crane Composites, Inc. Technical Department 8015 Dixon Drive Florence, Kentucky 41042 1.859.371.7720 DISCLAIMERS (Please read) PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION These guidelines are provided in good faith to help prevent installation problems caused by common errors. The manufacturer and/or distributor of the product bears no responsibility for installation actions taken or not taken. There are many nuances of installation that are assumed to be general construction knowledge to an experienced installer; such nuances are not included in these instructions. Rather, these installation guidelines are strictly recommendations and are not intended to serve as a step-by-step, foolproof installation checklist. Selection of an experienced frp installer is the sole responsibility of the project owner and architect. Crane Composites does not accept any responsibility for job failure resulting from or associated with improper job site environmental conditions. www.frp.com 1 1.800.435.0080 1 1.815.467.8666 (fax) I salesbp@cranecomposites.com 4 CRANE ' Composites Crane Composites is the maker of Glasbord, Sequentia, Samgrid 11 and a variety of other fiberglass reinforced plastic (frp) composite wall panels. Inspired by ? p the Kemlite tradition. Crane Composites has over 50 years of experience in commercial building products and is a recognized industry leader in frp applications. a crane Co. company Form 39001 Rev. 0 13.10 1 (5434 ) Duralite is a registered trademark of Crane Composites, Inc.