HomeMy WebLinkAboutProduct Approval Roof DecFlorida Building Code Online
Page 1 of 2
,..,F-s Cri0hC 74RRtEKtiQF.. �%a y,�s. }� Er ..� �-C zrx �,ac +%� Rs .e --s -vim "s`t•* II '' `
uxaa.. n€.rc,s.:,ae*•., xn, ,...n...�Z s�.'..rmrox�.3.�..mSx: � �r, ��F.�� _ .t......_ . �. � .... , ....�
te
T
• •�
Product Approval
USER: Public User
s.
ApprovalProduct
Application Type New
Code Version 2020
Application Status Approved
Comments
'.i}FSEFIEE.Q �r;.l
Product Manufacturer Crane Composites, Inc
Address/Phone/Email 8015 Dixon Drive
Florence, KY 41042
(859) 283-6136
abarry@cranecomposites.com
Authorized Signature Allison Barry
abarry@cranecomposites.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Structural Components
Subcategory Roof Deck
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
El Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Farabaugh Engineering and Testing, Inc
Quality Assurance Contract Expiration Date 09/30/2024
Validated By Yoosef Lavi, P.E.
2 Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL38459 RO COI CertificateIndeoendence odf
Standard
Year
ASTM D1929
2016
ASTM D635
2014
ASTM E84
2016
FM 4470
2016
UL 580
2006
https://floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsBkU5zAW6hSxG... 4/ 19/2022
Florida Building Code Online
Page 2 of 2 ' it
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
04/17/2021
04/19/2021
04/26/2021
06/09/2021
FL #
Model, Number or Name
Description
38459.1
Duralite High Strength R-Panel
Fiber reinforced plastic (FRP) roof panel
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL38459 RO II Crane Installation Guide 25 May 2010.odf
Verified By: Andy Wermeling Kentucky PE
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: No
Design Pressure: +41.6/-41.6
Evaluation Reports
Other: Inward and outward load of 41.6 psf at support
FL38459 RO AE Eva luationReoortC2440 2.Ddf
spacing of 60" D.C.
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
—M W ® N
Credit Card
https://floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsBkU5zAW6hSxG... 4/19/2022
ME A
390C
I, IN W4 W
i " -�;' k "i 1 5 Mq_ e - - wrl�
w�ff-maiii-M."�
tal"i.
i�
IN.. ION
GUIDE
.... .....
r
LITE HIGH STRENGTH
R-PANEL (Tool #162)
DISCLAIMERS
(Please read)
PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION
These guidelines are provided in good faith to help prevent installation problems caused by common errors. The manufacturer and/or distributor of
the product bears no responsibility for installation actions taken or not taken. There are many nuances of installation that are assumed to be general
construction knowledge to an experienced installer; such nuances are not included in these instructions. Rather, these installation guidelines are
strictly recommendations and are not intended to serve as a step-by-step, foolproof installation checklist. Selection of an experienced frp installer is the
sole responsibility of the project owner and architect.
Crane Composites does not accept any responsibility forjob failure resulting from or associated with improperjob site environmental conditions.
:The instructiions' provided in:.this document are applicable for:�nstailab'dn'of both roofs; and walls..
www.frp.com 1 1.800.435.0080 1 1.815.467.8666 (fax) I salesbp@cranecomposites.com _ CRANE Composites
Crane Composites is the maker of Glasbord, Sequentia. Sanigdd II and a variety of other fiberglass reinforced plastic (frp) composite wall panels. Inspired by y P
the Kemlite tradition, Crane Composites has over 50 years of experience in commercial building products and is a recognized industry leader in frp applications. A crane Ca Company
Form 3900 1 Rev. 0 13.10 1 (5434) Duralite is a registered trademark of Crane Composites, Inc.
CRANE Composites
Duralite High Strength R-Panel I Installation Guide
37.75 in
36.00 in
12.00 in in 1.00 in
N
4.00 in 4.00 in 1.00 in
1.38 in 4----I
0 3.06 in
3900
Rev. 0 13.10
C RA N E
Composites
DRAWN
DATE
BY RCK
1/18/10
SCALE
N.T.S.
DWG.
R PANEL 162
PANEL PROFILE
REV.
0
C.E.R.
NA
R-Panel I Profile Tool #162
Purlin Fasteners With Washers: #12-14 x 1" self -tapping screws with corrosion resistant coating and 1
%8" stainless steel washer backer with an EPDM gasket.
Side Lap Fasteners: #6 x 1'/" stainless steel grommet with hex head machine screw and neoprene
sleeve.
MCRANEComposites
Duralite High Strength R-Panel I Installation Guide
Figure 1: Tape Sealer Placement — Lower Panel
3900
Rev. 0 13.10
Apply tape sealer to lower panel: apply along peak of major ribs (2) for side laps and across panel width
at downslope for sealing end lap.
CRANE Composites
3900
Duralite High Strength R-Panel I Installation Guide Rev. 0 13.10
DPE
IN
& MIDSPAN PURLIN PURLIN
3 1/2" O.C.
Figure 2: Fasten Light Transmitting Panel to Purlins
Fasten light transmitting panel to the purlin at the downslope end and to the intermediate purlin. For
each purlin, use 9 Purlin fasteners with washers.
See Figure 3 for fastening detail and Figure 4 for fastener spacing.
'M! CRAN E Composites
3900
Duralite High Strength R-Panel I Installation Guide Rev. 0 13.10
PyErSTSIM
1.00
LIGHT TRANSMITTING FRP
PURLIN
Figure 3: Fastening Detail for End lap at Downslope
PURLIN FASTENER
%SHER
TAPE SEALER 3/16" X 1"
w. CRANE Composites
Duralite High Strength R-Panel I Installation Guide
3.50 in TYP. 5.00 in
TYP.
3.50 in TYP.
Figure 4: Fastener Spacing for Fastening to Purlins
3900
Rev. 0 13.10
aCRANE Composites
Duralite High Strength R-Panel I Installation Guide
3900
Rev. 0 13.10
IN
PE
J
Q
PURLIN �v
Figure 5: Install Upper Metal Panel and Fasten Side Laps
Make certain sealer tape has been applied for the side laps and for the end lap at the upslope.
Fasten side laps with panel side lap fasteners 10" on center.
Fasten end lap at upslope with 9 Purlin Fasteners
See Figure 6 for fastening detail and Figure 4 for fastener spacing.
0 CRANE Composites
Duralite High Strength R-Panel I Installation Guide
UPPER ROOF PANEL
FAMATAIM
1.00
PURLIN FASTENER
HASHER
3900
Rev. 0 13.10
`mod TAPE SEALER 3/16" X 1"
LIGHT TRANSMITTING FRP
PURLIN
Figure 6: Fastening Detail for End Lap at Upslope
R r� CRANE Composites
Duralite High Strength R-Panel I Installation Guide
3900
Rev. 0 13.10
Any questions about installation can be directed to:
Crane Composites, Inc. Technical Department
8015 Dixon Drive
Florence, Kentucky 41042
1.859.371.7720
DISCLAIMERS
(Please read)
PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION
These guidelines are provided in good faith to help prevent installation problems caused by common errors. The manufacturer and/or distributor of
the product bears no responsibility for installation actions taken or not taken. There are many nuances of installation that are assumed to be general
construction knowledge to an experienced installer; such nuances are not included in these instructions. Rather, these installation guidelines are
strictly recommendations and are not intended to serve as a step-by-step, foolproof installation checklist. Selection of an experienced frp installer is the
sole responsibility of the project owner and architect.
Crane Composites does not accept any responsibility for job failure resulting from or associated with improper job site environmental conditions.
www.frp.com 1 1.800.435.0080 1 1.815.467.8666 (fax) I salesbp@cranecomposites.com 4 CRANE ' Composites
Crane Composites is the maker of Glasbord, Sequentia, Samgrid 11 and a variety of other fiberglass reinforced plastic (frp) composite wall panels. Inspired by ? p
the Kemlite tradition. Crane Composites has over 50 years of experience in commercial building products and is a recognized industry leader in frp applications. a crane Co. company
Form 39001 Rev. 0 13.10 1 (5434 ) Duralite is a registered trademark of Crane Composites, Inc.