HomeMy WebLinkAboutEnergy Efficiency Code6uW�lu,�ed 'Alun0D Don- 1 '1S FORM R405-2020 z 0 d�'W FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING C .NST T,l N -�� ! f.,I Florida Department of Business and Professional Regulation - Residential Performance Metho�----- 9 • Project Name: Hall Residence -12793 W Angle Road Builder Name: Trefelner Construction, Inc. Street: 12793, W. Angle Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34945 Permit Number: Owner: Robert & Roxanne Hall Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall TypeV692.1 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, Exterior R=4.1 2309.40 ft2 b. Frame - Wood, Adjacent R=11.0 382.67 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (2656.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2656.00 ft2 6. Conditioned floor area above grade (111:2) 2656 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(313.8 sqft.) Description Area 12. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 135 a. U-Factor: Dbl, U=0.65 245.17 ft2 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.65 68.67 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 44.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 5.866 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.261 a. Electric Strip Heat 34.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Propane Tankless Cap: 1 gallons 9. Floor Types (2656.0 sqft.) Insulation Area EF: 0.600 a. Slab -On -Grade Edge Insulation R=0.0 2656.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits CF, Pstat Total Proposed Modified Loads: 66.80 Glass/Floor Area: 0.118 PASS Total Baseline Loads: 70.60 I hereby certify that the plans and specifications covered by Review of the plans and ST this calculation are in compliance with the Florida Energy specifications covered by this 0VT'E1E �y p Code. calculation indicates compliance y �,,';- with the Florida Energy Code. E. lrnn''�% .'.s� ��•�`=�;, �O PREPARED BY: Before construction is completed DATE: 3-2-2022 this building will be inspected for compliance with Section 553.908 a hereby certify that this building, as de si ned, is in compliance Florida Statutes. with the Florida Energy ode. OWNER/AGENT: ' BUILDING OFFICIAL: DATE: 2 Z DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2). 3/2/2022 8:32 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Co lia�f rrCopy Page 1 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Hall Residence -12793 W An Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 2656 Lot # Owner Name: Robert & Roxanne Hall Total Stories: 1 Block/Subdivision: # of Units: , 1 Worst Case: No PlatBook: Builder Name: Trefelner Construction, Inc. Rotate Angle: 225 Street: 12793 W. Angle Road Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34945 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2656 25726.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M.Closet 96 902.4 No 0 1 Yes Yes Yes 2 Toilet 28 263 No 0 1 Yes Yes Yes 3 Master Bath 162 1523 No 0 1 Yes Yes Yes 4 Master Bedroom 233 2190 No 2 1 Yes Yes Yes 5 Laundry 100 940 No 0 1 Yes Yes Yes 6 Pantry 70 658 No 0 1 No Yes Yes 7 Hall 118 1109 No 0 1 No Yes Yes 8 Cafe 117 1100 No 1 1 Yes Yes Yes 9 Kitchen 280 2632 No 2 1 Yes Yes Yes 10 Family Room 380 4332 No 1 1 Yes Yes Yes 11 Bedroom 2 151 1419 No 1 1 Yes Yes Yes 12 Closet 36 338 No 0 1 Yes Yes Yes 13 Bath 3 108 1015 No 0 1 Yes Yes Yes 14 Dining 169 1589 No 1 1 Yes Yes Yes 15 Foyer 104 978 No 0 1 Yes Yes Yes 16 Closet 32 301 No 0 1 No Yes Yes 17 Bedroom 4 120 1128 No 1 1 Yes Yes Yes 18 Closet 36 338, No 0 1 Yes Yes Yes 19 Bedroom 3 172 1617 No 1 1 Yes Yes Yes 20 Hall1 64 602 No 0 1 No Yes Yes 21 Bath 2 80 752 No 0 1 Yes Yes Yes 3/2/2022 8:32 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type F-= Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio M. Closet 18 ft 0 96 ftz 1 0 0 2 Slab -On -Grade Edge Insulatio Toilet 7 ft 0 28 ftz 1 0 0 3 Slab -On -Grade Edge Insulatio Master Bath 7 ft 0 162 ftz 1 0 0 4 Slab -On -Grade Edge Insulatio Master Bedroom 24 ft 0 233 ftz °e 1 0 0 5 Slab -On -Grade Edge Insulatio Laundry loft 0 100 ftz 1 0 0 6 Slab -On -Grade Edge Insulatio Pantry 1 ft 0 70 ftz ___ 1 0 0 7 Slab -On -Grade Edge Insulatio Hall 1 ft 0 118 ftz 1 0 0 8 Slab -On -Grade Edge Insulatio Cafe 22 ft 0 117 ftz e__ 1 0 0 9 Slab -On -Grade Edge Insulatio Kitchen 1 ft 0 280 ftz 1 0 0 10SIab-On-Grade Edge Insulatio Family Room 20 ft 0 380 ftz ___ 1 0 0 11SIab-On-Grade Edge Insulatio Bedroom 2 14 ft 0 151 ftz ___ 1 0 0 12SIab-On-Grade Edge Insulatio Closet 2 4 ft 0 36 ftz 1 0 0 13SIab-On-Grade Edge Insulatio Bath 3 12 ft 0 108 ftz 1 0 0 14SIab-On-Grade Edge Insulatio Dining 15 ft 0 169 ftz ____ 1 0 0 15SIab-On-Grade Edge Insulatio Foyer 8 ft 0 104 ftz e_ 1 0 0 16SIab-On-Grade Edge Insulatio Closet 4 1 ft 0 32 ftz 1 0 0 17SIab-On-Grade Edge Insulatio Bedroom 4 14 ft 0 120 ftz 1 0 0 18SIab-On-Grade Edge Insulatio Closet 3 4 ft 0 36 ftz 1 0 0 19SIab-On-Grade Edge Insulatio Bedroom 3 35 ft 0 172 ftz 1 0 0 20SIab-On-Grade Edge Insulatio Hall1 1 ft 0 64 ftz -_ 1 0 0 21SIab-On-Grade Edge Insulatio Bath 2 26 ft 0 80 ftz 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch 1/ # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2970 ftz 0 ftz Light N 0.6 No 0.9 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2656 ftz N N 3/2/2022 8:32 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) M. Closet 20 Blown 96 ft2 0.1 , Wood 2 Under Attic (Unvented) Toilet 20 Blown 28 ft2 0.1 Wood 3 Under Attic (Unvented) Master Bath 20 Blown 162 ft2 0.1 Wood 4 Under Attic (Unvented) Master Bedroom 20 Blown 233 ft2 0.1 Wood 5 Under Attic (Unvented) Laundry 20 Blown 100 ftz 0.1 Wood 6 Under Attic (Unvented) Pantry 20 Blown 70 ft2 0.1 Wood 7 Under Attic (Unvented) Hall 20 Blown 118 ft2 0.1 Wood 8 Under Attic (Unvented) Cafe 20 Blown 117 ft2 0.1 Wood 9 Under Attic (Unvented) Kitchen 20 Blown 280 ft2 0.1 Wood 10 Under Attic (Unvented) Family Room 20 Blown 380 ft2 0.1 Wood 11 Under Attic (Unvented) Bedroom 2 20 Blown 151 ft2 0.1 Wood 12 Under Attic (Unvented) Closet 2 20 Blown 36 ft2 0.1 Wood 13 Under Attic (Unvented) Bath 3 20 Blown 108 ft2 0.1 Wood 14 Under Attic (Unvented) Dining 20 Blown 169 ft2 0.1 Wood 15 Under Attic (Unvented) Foyer 20 Blown 104 ft2 0.1 Wood 16 Under Attic (Unvented) Closet 4 20 Blown 32 ft2 0.1 Wood 17 Under Attic (Unvented) Bedroom 4 20 Blown 120 ft2 0.1 Wood 18 Under Attic (Unvented) Closet 3 20 Blown 36 ft2 0.1 Wood 19 Under Attic (Unvented) Bedroom 3 20 Blown 172 ft2 0.1 Wood 20 Under Attic (Unvented) Hall1 20 Blown 64 ft2 0.1 Wood 21 Under Attic (Unvented) Bath 2 20 Blown 80 ft2 0.1 Wood WALLS Adjacent SpaceArs-n Cavity Width Height Sheathing Framing Solar Below o 1 S=>NE Exterior Concrete Block - Ext InsuM. Closet 4.1 9 0 9 5 84.8 ft2 0 0 0.6 0 2 W=>SE Exterior Concrete Block - Ext InsuM. Closet 4.1 9 0 9 5 84.8 ft2 0 0 0.6 0 3 S=>NE Exterior Concrete Block - Ext Insul Toilet 4.1 7 0 9 5 65.9 ft2 0 0 0.6 0 4 S=>NE Exterior Concrete Block - Ext InsMaster Bath 4.1 7 0 9 5 65.9 ft2 0 0 0.6 0 5 N=>SW Exterior Concrete Block - Ext InMhster Bedro 4.1 7 0 9 5 65.9 ft2 0 0 0.6 0 6 E=>NW Exterior Concrete Block - Ext Inddhster Bedro 4.1 1 0 9 5 9.4 ft2 0 0 0.6 0 7 . W=>SE Exterior Concrete Block - Ext InsMhster Bedro 4.1 16 0 9 5 150.7 ft2 0 0 0.6 0 8 S=>NE Exterior Concrete Block - Ext Insul Laundry 4.1 10 0 9 5 94.2 ft2 0 0 0.6 0 9 N=>SW Exterior Concrete Block - Ext Insul Cafe 4.1 9 0 9 5 84.8 ft2 0 0 0.6 0 10 W=>SE Exterior Concrete Block - Ext Insul Cafe 4.1 13 0 9 5 122.4 ft2 0 0 0.6 0 11 W=>SE Exterior Concrete Block - Ext Insul Kitchen 4.1 1 0 9 5 9.4 ft2 0 0 0.6 0 12 W=>SE Exterior Concrete Block- Ext IndiAmily Room 4.1 20 0 11 5 228.3 ft2 0 0 0.6 0 _ 13 N=>SW Exterior Concrete Block - Ext InstBedroom 2 4.1 11 0 9 5 103.6 ft2 0 0 0.6 0 _ 14 W=>SE Exterior Concrete Block - Ext InsiBedroom 2 4.1 3 0 9 5 28.3 ft2 0 0 0.6 0 15 N=>SW Exterior Concrete Block - Ext Insul Closet 2 4.1 4 0 9 5 37.7 ft2 0 0 0.6 0 16 N=>SW Exterior Concrete Block - Ext Insul Bath 3 4.1 12 0 9 5 113.0 ft2 0 0 0.6 0 17 N=>SW Exterior Concrete Block - Ext Insul Dining 4.1 2 0 9 5 18.8 ft2 0 0 0.6 0 18 E=>NW Exterior Concrete Block - Ext Insul Dining 4.1 13 0 9 5 122.4 ft2 0 0 0.6 0 19 E=>NW Exterior Concrete Block - Ext Insul Foyer 4.1 8 0 9 5 75.3 ft2 0 0 0.6 0 3/2/2022 8:32 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _20 E=>NW Exterior Concrete Block - Ext InstBedroom 4 4.1 12 0 9 5 113.0 ft2 0 0 0.6 0 _ 21 S=>NE Exterior Concrete Block - Ext InstBedroom 4 4.1 2 0 9 5 18.8 ft2 0 0 0.6 0 _22 N=>SW Exterior Concrete Block - Ext Insul Closet 3 4.1 4 0 9 5 37.7 ft2 0 0 0.6 0 _23 N=>SW Exterior Concrete Block - Ext InstBedroom 3 4.1 12 0 9 5 113.0 ft2 0 0 0.6 0 _24 E=>NW Exterior Concrete Block - Ext InsiBedroom 3 4.1 13 0 9 5 122.4 ft2 0 0 0.6 0 _25 S=>NE Exterior Concrete Block - Ext InstBedroom 3 4.1 10 0 9 5 94.2 ft2 0 0 0.6 0 _26 N=>SW Exterior Concrete Block - Ext Insul Bath 2 4.1 8 0 9 5 75.3 ft2 0 0 0.6 0 _27 S=>NE Exterior Concrete Block - Ext Insul Bath 2 4.1 8 0 9 5 75.3 ft2 0 0 0.6 0 _28 W=>SE Exterior Concrete Block - Ext Insul Bath 2 4.1 10 0 9 5 94.2 ft2 0 0 0.6 0 _29 N=>SW Garage Frame - Wood Laundry 11 10 9 4 93.3 1`12 0 0.23 0.600000 0 _30 N=>SW Garage Frame - Wood Pantry 11 11 9 4 102.7 ft2 0 0.23 0.600000 0 _31 N=>SW Garage Frame - Wood Hall 11 4 9 4 37.3 ft2 0 0.23 0.600000 0 _32 N=>SW Garage Frame - Wood Kitchen 11 3 9 4 28.0 ft2 0 0.23 0.600000 0 _33 N=>SW Garage Frame - Wood Dining 11 13 9 4 121.3 ft2 0 0.23 0.600000 0 DOORS # Omt Door Type Space Storms LI-Value Width Height Area Ft In Ft In 1 E=>NW Wood Foyer None .39 3 8 24 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 225 degrees). V Wall Overhang # Ornt ID Frame Panes NFRC LI-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S=>NE 3 Metal Low-E Double Yes 0.65 0.25 N 8.0 ft2 1 ft 7 in 1 ft 4 in None None 2 S=>NE 4 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft2 1 ft 7 in 1 it 4 in None None 3 W=>SE 7 Metal Low-E Double Yes 0.65 0.25 N 15.0 112 1 ft 7 in 1 ft 4 in None None 4 W=>SE 7 Metal Low-E Double Yes 0.65 0.25 N 15.4 1`12 1 ft 7 in 1 ft 4 in None None 5 W=>SE 10 Metal Low-E Double Yes 0.65 0.25 N 29.2 ft2 1 ft 7 in 1 ft 4 in None None 6 W=>SE 12 Metal Low-E Double Yes 0.65 0.3 N 48.0 ft2 12 it 0 in 1 ft 4 in 'None None 7 W=>SE 12 Metal Low-E Double Yes 0.65 0.25 N 13.8 ft2 12 ft 0 in 1 it 4 in None None 8 W=>SE 12 Metal Low-E Double Yes 0.65- 0.25 N 14.2 ft2 12 ft 0 in 1 it 4 in None None 9 W=>SE 12 Metal Low-E Double Yes 0.65 0.25 N 14.6 ft2 12 it 0 in 1 ft 4 in None None 10 N=>SW 13 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft2 1 ft 7 in 1 ft 4 in None None 11 N=>SW 16 Metal Low-E Double Yes 0.65 0.25 N 16.0 ft2 1 ft 7 in 1 ft 4 in None None 12 E=>NW 18 Metal Low-E Double Yes 0.65 0.25 N 14.6 ft2 7 ft 0 in 1 ft 4 in None None 13 E=>NW 18 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft2 7 ft 0 in 1 ft 4 in None None 14 E=>NW 19 Metal Low-E Double Yes 0.65 0.25 N 7.3 ft2 7 ft 0 in 1 ft 4 in None None 15 E=>NW 19 Metal Low-E Double Yes 0.65 0.25 N 8.0 ft2 7 ft 0 in 1 ft 4 in None None 16 E=>NW 20 Metal Low-E Double Yes 0.65 0.25 N 29.2 ft2 7 ft 0 in 1 ft 4 in None None 17 E=>NW 24 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft2 1 ft 7 in 1 ft 4 in None None 18 W=>SE 28 Metal Low-E Double Yes 0.65 0.3 N 20.7 ft2 1 ft 7 in 1 it 4 in None None 3/2/2022 8:32 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST RFPnRT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 650 ft' 650 ftz 41 ft 9.4 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000431 3001.4 164.67 309.14 .1364 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 44 kBtu/hr 1320 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Garage 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftz DUCTS # -- Supply — Location R-Value Area — Return— Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 135 ftz Attic 40 ft2 Default Leakage Attic (Default) (Default) 1 1 3/2/2022 8:32 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHFCKI_IST RFPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan jj jj Feb HeatinJan (X] Feb Mar Mar A r E Apr f May May Jun Jun Jul Jul Auge Au4 Sep Oct f Oct Nov Nov Dec Dec VentingJan [[ jj Feb Mar [Xl Apr [ May Jun Jul Aug [ Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 M. Closet Default(8 Ibs/sq.ft. ft2 ft 0.3 Toilet Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Pantry Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall Default(8 Ibs/sq.ft. ft2 ft 0.3 Cafe Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Family Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Closet 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Closet 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 4 Default(8 Ibs/sq.ft.' ft2 ft U Closet 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Halll Default(8 Ibs/s .ft. ft2 ft 0.3 Bath 2 3/2/2022 8:32 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Hall Residence - 12793 W Angle Road Builder Name: Trefelner Construction, Inc. Street: 12793 W. Angle Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34945 Permit Number: U Owner: Robert & Roxanne Hall Jurisdiction: St. Lucie County w Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extPrid behind piping and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-flcor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or cewlings, a. In addition, inspection of log walls shall be In accordance with the provisions of [CC-400. 3/2/2022 8:33 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1