HomeMy WebLinkAboutEnergy Efficiency Code6uW�lu,�ed 'Alun0D Don-
1 '1S
FORM R405-2020 z 0 d�'W
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING C .NST T,l N
-�� ! f.,I
Florida Department of Business and Professional Regulation - Residential Performance Metho�-----
9 •
Project Name: Hall Residence -12793 W Angle Road
Builder Name: Trefelner Construction, Inc.
Street: 12793, W. Angle Road
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL, 34945
Permit Number:
Owner: Robert & Roxanne Hall
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall TypeV692.1 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Ext Insul, Exterior
R=4.1 2309.40 ft2
b. Frame - Wood, Adjacent
R=11.0 382.67 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 0
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2656.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2656.00 ft2
6. Conditioned floor area above grade (111:2) 2656
b. NIA
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(313.8 sqft.) Description Area
12. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 135
a. U-Factor: Dbl, U=0.65 245.17 ft2
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.65 68.67 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
44.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 5.866 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.261
a. Electric Strip Heat
34.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Propane Tankless
Cap: 1 gallons
9. Floor Types (2656.0 sqft.) Insulation Area
EF: 0.600
a. Slab -On -Grade Edge Insulation R=0.0 2656.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
CF, Pstat
Total Proposed Modified Loads: 66.80
Glass/Floor Area: 0.118
PASS
Total Baseline Loads: 70.60
I hereby certify that the plans and specifications covered by
Review of the plans and
ST
this calculation are in compliance with the Florida Energy
specifications covered by this
0VT'E1E
�y p
Code.
calculation indicates compliance
y �,,';-
with the Florida Energy Code.
E. lrnn''�% .'.s� ��•�`=�;, �O
PREPARED BY:
Before construction is completed
DATE: 3-2-2022
this building will be inspected for
compliance with Section 553.908
a
hereby certify that this building, as de si ned, is in compliance
Florida Statutes.
with the Florida Energy ode.
OWNER/AGENT: '
BUILDING OFFICIAL:
DATE: 2 Z
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2).
3/2/2022 8:32 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Co lia�f rrCopy Page 1 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Hall Residence -12793 W An
Bedrooms: 0
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2656
Lot #
Owner Name:
Robert & Roxanne Hall
Total Stories: 1
Block/Subdivision:
# of Units: ,
1
Worst Case: No
PlatBook:
Builder Name:
Trefelner Construction,
Inc.
Rotate Angle: 225
Street:
12793 W. Angle Road
Permit Office:
St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
St. Lucie County
Whole House Fan: No
City, State,
Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34945
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70 75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2656
25726.4
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms InfilID
Finished Cooled
Heated
1
M.Closet
96
902.4 No
0
1
Yes
Yes
Yes
2
Toilet
28
263 No
0
1
Yes
Yes
Yes
3
Master Bath
162
1523 No
0
1
Yes
Yes
Yes
4
Master Bedroom
233
2190 No
2
1
Yes
Yes
Yes
5
Laundry
100
940 No
0
1
Yes
Yes
Yes
6
Pantry
70
658 No
0
1
No
Yes
Yes
7
Hall
118
1109 No
0
1
No
Yes
Yes
8
Cafe
117
1100 No
1
1
Yes
Yes
Yes
9
Kitchen
280
2632 No
2
1
Yes
Yes
Yes
10
Family Room
380
4332 No
1
1
Yes
Yes
Yes
11
Bedroom 2
151
1419 No
1
1
Yes
Yes
Yes
12
Closet
36
338 No
0
1
Yes
Yes
Yes
13
Bath 3
108
1015 No
0
1
Yes
Yes
Yes
14
Dining
169
1589 No
1
1
Yes
Yes
Yes
15
Foyer
104
978 No
0
1
Yes
Yes
Yes
16
Closet
32
301 No
0
1
No
Yes
Yes
17
Bedroom 4
120
1128 No
1
1
Yes
Yes
Yes
18
Closet
36
338, No
0
1
Yes
Yes
Yes
19
Bedroom 3
172
1617 No
1
1
Yes
Yes
Yes
20
Hall1
64
602 No
0
1
No
Yes
Yes
21
Bath 2
80
752 No
0
1
Yes
Yes
Yes
3/2/2022 8:32 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
F-=
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
M. Closet
18 ft
0
96 ftz
1
0
0
2 Slab -On -Grade Edge Insulatio
Toilet
7 ft
0
28 ftz
1
0
0
3 Slab -On -Grade Edge Insulatio
Master Bath
7 ft
0
162 ftz
1
0
0
4 Slab -On -Grade Edge Insulatio
Master Bedroom 24 ft
0
233 ftz
°e
1
0
0
5 Slab -On -Grade Edge Insulatio
Laundry
loft
0
100 ftz
1
0
0
6 Slab -On -Grade Edge Insulatio
Pantry
1 ft
0
70 ftz
___
1
0
0
7 Slab -On -Grade Edge Insulatio
Hall
1 ft
0
118 ftz
1
0
0
8 Slab -On -Grade Edge Insulatio
Cafe
22 ft
0
117 ftz
e__
1
0
0
9 Slab -On -Grade Edge Insulatio
Kitchen
1 ft
0
280 ftz
1
0
0
10SIab-On-Grade Edge Insulatio
Family Room
20 ft
0
380 ftz
___
1
0
0
11SIab-On-Grade Edge Insulatio
Bedroom 2
14 ft
0
151 ftz
___
1
0
0
12SIab-On-Grade Edge Insulatio
Closet 2
4 ft
0
36 ftz
1
0
0
13SIab-On-Grade Edge Insulatio
Bath 3
12 ft
0
108 ftz
1
0
0
14SIab-On-Grade Edge Insulatio
Dining
15 ft
0
169 ftz
____
1
0
0
15SIab-On-Grade Edge Insulatio
Foyer
8 ft
0
104 ftz
e_
1
0
0
16SIab-On-Grade Edge Insulatio
Closet 4
1 ft
0
32 ftz
1
0
0
17SIab-On-Grade Edge Insulatio
Bedroom 4
14 ft
0
120 ftz
1
0
0
18SIab-On-Grade Edge Insulatio
Closet 3
4 ft
0
36 ftz
1
0
0
19SIab-On-Grade Edge Insulatio
Bedroom 3
35 ft
0
172 ftz
1
0
0
20SIab-On-Grade Edge Insulatio
Hall1
1 ft
0
64 ftz
-_
1
0
0
21SIab-On-Grade Edge Insulatio
Bath 2
26 ft
0
80 ftz
1
0
0
ROOF
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
1/ # Type Materials
Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip Metal 2970 ftz
0 ftz Light
N
0.6 No 0.9
No
20
26.6
ATTIC
V # Type
Ventilation
Vent
Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0 2656 ftz
N N
3/2/2022 8:32 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) M. Closet
20
Blown
96 ft2
0.1 ,
Wood
2
Under Attic (Unvented) Toilet
20
Blown
28 ft2
0.1
Wood
3
Under Attic (Unvented) Master Bath
20
Blown
162 ft2
0.1
Wood
4
Under Attic (Unvented) Master Bedroom
20
Blown
233 ft2
0.1
Wood
5
Under Attic (Unvented) Laundry
20
Blown
100 ftz
0.1
Wood
6
Under Attic (Unvented) Pantry
20
Blown
70 ft2
0.1
Wood
7
Under Attic (Unvented) Hall
20
Blown
118 ft2
0.1
Wood
8
Under Attic (Unvented) Cafe
20
Blown
117 ft2
0.1
Wood
9
Under Attic (Unvented) Kitchen
20
Blown
280 ft2
0.1
Wood
10
Under Attic (Unvented) Family Room
20
Blown
380 ft2
0.1
Wood
11
Under Attic (Unvented) Bedroom 2
20
Blown
151 ft2
0.1
Wood
12
Under Attic (Unvented) Closet 2
20
Blown
36 ft2
0.1
Wood
13
Under Attic (Unvented) Bath 3
20
Blown
108 ft2
0.1
Wood
14
Under Attic (Unvented) Dining
20
Blown
169 ft2
0.1
Wood
15
Under Attic (Unvented) Foyer
20
Blown
104 ft2
0.1
Wood
16
Under Attic (Unvented) Closet 4
20
Blown
32 ft2
0.1
Wood
17
Under Attic (Unvented) Bedroom 4
20
Blown
120 ft2
0.1
Wood
18
Under Attic (Unvented) Closet 3
20
Blown
36 ft2
0.1
Wood
19
Under Attic (Unvented) Bedroom 3
20
Blown
172 ft2
0.1
Wood
20
Under Attic (Unvented) Hall1
20
Blown
64 ft2
0.1
Wood
21
Under Attic (Unvented) Bath 2
20
Blown
80 ft2
0.1
Wood
WALLS
Adjacent
SpaceArs-n
Cavity
Width
Height
Sheathing Framing Solar
Below
o
1
S=>NE
Exterior Concrete Block - Ext InsuM. Closet
4.1
9
0 9
5
84.8 ft2
0
0
0.6
0
2
W=>SE
Exterior Concrete Block - Ext InsuM. Closet
4.1
9
0 9
5
84.8 ft2
0
0
0.6
0
3
S=>NE
Exterior Concrete Block - Ext Insul Toilet
4.1
7
0 9
5
65.9 ft2
0
0
0.6
0
4
S=>NE
Exterior Concrete Block - Ext InsMaster Bath
4.1
7
0 9
5
65.9 ft2
0
0
0.6
0
5
N=>SW
Exterior Concrete Block - Ext InMhster Bedro
4.1
7
0 9
5
65.9 ft2
0
0
0.6
0
6
E=>NW
Exterior Concrete Block - Ext Inddhster Bedro
4.1
1
0 9
5
9.4 ft2
0
0
0.6
0
7
. W=>SE
Exterior Concrete Block - Ext InsMhster Bedro
4.1
16
0 9
5
150.7 ft2
0
0
0.6
0
8
S=>NE
Exterior Concrete Block - Ext Insul Laundry
4.1
10
0 9
5
94.2 ft2
0
0
0.6
0
9
N=>SW
Exterior Concrete Block - Ext Insul Cafe
4.1
9
0 9
5
84.8 ft2
0
0
0.6
0
10
W=>SE
Exterior Concrete Block - Ext Insul Cafe
4.1
13
0 9
5
122.4 ft2
0
0
0.6
0
11
W=>SE
Exterior Concrete Block - Ext Insul Kitchen
4.1
1
0 9
5
9.4 ft2
0
0
0.6
0
12
W=>SE
Exterior Concrete Block- Ext IndiAmily Room
4.1
20
0 11
5
228.3 ft2
0
0
0.6
0
_ 13
N=>SW
Exterior Concrete Block - Ext InstBedroom 2
4.1
11
0 9
5
103.6 ft2
0
0
0.6
0
_ 14
W=>SE
Exterior Concrete Block - Ext InsiBedroom 2
4.1
3
0 9
5
28.3 ft2
0
0
0.6
0
15
N=>SW
Exterior Concrete Block - Ext Insul Closet 2
4.1
4
0 9
5
37.7 ft2
0
0
0.6
0
16
N=>SW
Exterior Concrete Block - Ext Insul Bath 3
4.1
12
0 9
5
113.0 ft2
0
0
0.6
0
17
N=>SW
Exterior Concrete Block - Ext Insul Dining
4.1
2
0 9
5
18.8 ft2
0
0
0.6
0
18
E=>NW
Exterior Concrete Block - Ext Insul Dining
4.1
13
0 9
5
122.4 ft2
0
0
0.6
0
19
E=>NW
Exterior Concrete Block - Ext Insul Foyer
4.1
8
0 9
5
75.3 ft2
0
0
0.6
0
3/2/2022 8:32 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing
Solar Below
_20
E=>NW Exterior
Concrete Block - Ext InstBedroom
4
4.1
12
0
9 5
113.0 ft2
0
0
0.6 0
_ 21
S=>NE Exterior
Concrete Block - Ext InstBedroom
4
4.1
2
0
9 5
18.8 ft2
0
0
0.6 0
_22
N=>SW Exterior
Concrete Block - Ext Insul
Closet 3
4.1
4
0
9 5
37.7 ft2
0
0
0.6 0
_23
N=>SW Exterior
Concrete Block - Ext InstBedroom
3
4.1
12
0
9 5
113.0 ft2
0
0
0.6 0
_24
E=>NW Exterior
Concrete Block - Ext InsiBedroom
3
4.1
13
0
9 5
122.4 ft2
0
0
0.6 0
_25
S=>NE Exterior
Concrete Block - Ext InstBedroom
3
4.1
10
0
9 5
94.2 ft2
0
0
0.6 0
_26
N=>SW Exterior
Concrete Block - Ext Insul
Bath 2
4.1
8
0
9 5
75.3 ft2
0
0
0.6 0
_27
S=>NE Exterior
Concrete Block - Ext Insul
Bath 2
4.1
8
0
9 5
75.3 ft2
0
0
0.6 0
_28
W=>SE Exterior
Concrete Block - Ext Insul
Bath 2
4.1
10
0
9 5
94.2 ft2
0
0
0.6 0
_29
N=>SW Garage
Frame - Wood
Laundry
11
10
9 4
93.3 1`12
0
0.23 0.600000 0
_30
N=>SW Garage
Frame - Wood
Pantry
11
11
9 4
102.7 ft2
0
0.23 0.600000 0
_31
N=>SW Garage
Frame - Wood
Hall
11
4
9 4
37.3 ft2
0
0.23 0.600000 0
_32
N=>SW Garage
Frame - Wood
Kitchen
11
3
9 4
28.0 ft2
0
0.23 0.600000 0
_33
N=>SW Garage
Frame - Wood
Dining
11
13
9 4
121.3 ft2
0
0.23 0.600000 0
DOORS
# Omt
Door Type
Space
Storms
LI-Value
Width
Height
Area
Ft
In
Ft In
1 E=>NW Wood
Foyer
None
.39
3
8
24 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 225 degrees).
V
Wall
Overhang
# Ornt ID
Frame Panes
NFRC LI-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 S=>NE 3
Metal Low-E Double
Yes
0.65
0.25
N
8.0 ft2
1 ft 7 in
1 ft 4 in
None
None
2 S=>NE 4
Metal Low-E Double
Yes
0.65
0.25
N
15.0 ft2
1 ft 7 in
1 it 4 in
None
None
3 W=>SE 7
Metal Low-E Double
Yes
0.65
0.25
N
15.0 112
1 ft 7 in
1 ft 4 in
None
None
4 W=>SE 7
Metal Low-E Double
Yes
0.65
0.25
N
15.4 1`12
1 ft 7 in
1 ft 4 in
None
None
5 W=>SE 10
Metal Low-E Double
Yes
0.65
0.25
N
29.2 ft2
1 ft 7 in
1 ft 4 in
None
None
6 W=>SE 12
Metal Low-E Double
Yes
0.65
0.3
N
48.0 ft2
12 it 0 in
1 ft 4 in
'None
None
7 W=>SE 12
Metal Low-E Double
Yes
0.65
0.25
N
13.8 ft2
12 ft 0 in
1 it 4 in
None
None
8 W=>SE 12
Metal Low-E Double
Yes
0.65-
0.25
N
14.2 ft2
12 ft 0 in
1 it 4 in
None
None
9 W=>SE 12
Metal Low-E Double
Yes
0.65
0.25
N
14.6 ft2
12 it 0 in
1 ft 4 in
None
None
10 N=>SW 13
Metal Low-E Double
Yes
0.65
0.25
N
15.0 ft2
1 ft 7 in
1 ft 4 in
None
None
11 N=>SW 16
Metal Low-E Double
Yes
0.65
0.25
N
16.0 ft2
1 ft 7 in
1 ft 4 in
None
None
12 E=>NW 18
Metal Low-E Double
Yes
0.65
0.25
N
14.6 ft2
7 ft 0 in
1 ft 4 in
None
None
13 E=>NW 18
Metal Low-E Double
Yes
0.65
0.25
N
15.0 ft2
7 ft 0 in
1 ft 4 in
None
None
14 E=>NW 19
Metal Low-E Double
Yes
0.65
0.25
N
7.3 ft2
7 ft 0 in
1 ft 4 in
None
None
15 E=>NW 19
Metal Low-E Double
Yes
0.65
0.25
N
8.0 ft2
7 ft 0 in
1 ft 4 in
None
None
16 E=>NW 20
Metal Low-E Double
Yes
0.65
0.25
N
29.2 ft2
7 ft 0 in
1 ft 4 in
None
None
17 E=>NW 24
Metal Low-E Double
Yes
0.65
0.25
N
15.0 ft2
1 ft 7 in
1 ft 4 in
None
None
18 W=>SE 28
Metal Low-E Double
Yes
0.65
0.3
N
20.7 ft2
1 ft 7 in
1 it 4 in
None
None
3/2/2022 8:32 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST RFPnRT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
650 ft'
650 ftz
41 ft 9.4 ft 11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000431
3001.4 164.67 309.14 .1364 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Strip Heat/
None
COP:1 34 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 44 kBtu/hr 1320 cfm 0.7 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Propane Tankless
Garage
0.6 1 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
None
None
ftz
DUCTS
#
-- Supply —
Location R-Value Area
— Return— Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1
Attic 6 135 ftz
Attic
40 ft2 Default Leakage Attic (Default) (Default)
1 1
3/2/2022 8:32 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020 INPUT SUMMARY CHFCKI_IST RFPORT
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan jj jj Feb
HeatinJan (X] Feb
Mar
Mar
A r
E Apr
f
May
May
Jun
Jun
Jul
Jul
Auge
Au4
Sep
Oct
f Oct
Nov
Nov
Dec
Dec
VentingJan [[ jj Feb
Mar
[Xl Apr
[
May
Jun
Jul
Aug
[
Se
[X] Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH) AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD) AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH) AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
M. Closet
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Toilet
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Laundry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Pantry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Cafe
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Family Room
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Closet 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Dining
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Foyer
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Closet 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 4
Default(8 Ibs/sq.ft.'
ft2
ft
U
Closet 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Halll
Default(8 Ibs/s .ft.
ft2
ft
0.3
Bath 2
3/2/2022 8:32 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Hall Residence - 12793 W Angle Road Builder Name: Trefelner Construction, Inc.
Street: 12793 W. Angle Road Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL, 34945 Permit Number:
U
Owner: Robert & Roxanne Hall Jurisdiction: St. Lucie County
w
Design Location: FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extPrid behind piping and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-flcor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or cewlings,
a. In addition, inspection of log walls shall be In accordance with the provisions of [CC-400.
3/2/2022 8:33 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1