Loading...
HomeMy WebLinkAboutFloor Plana H34 s.h. L-1 25 s.h. Safety Glass HB IN O L-3 v 1 70'-0" 24'-0- 12'-8- 23'-4" 10'-0" 9'-6" 2`11 "" 4'-5" T-10" 4'-5" 1' X'2" 5'-9" T-10- 3'-10' 5'-5' 5'-7- 4'-5" 1`11- 16" 71 25 s.h. Egress L-1 25 s.h. Egress L-1 0 0� o o a oa 8"" oL 0 r 25 . s.Porch 8" 4" 14'-0"" 4'-0„ 4' o o � Bdrm. 9'-4" Ceiling 00 ❑• 00-- l 9'-4„ Cing. Al O oL U "o 0 °' I L-6Master p O O RJ O from FFE 8" Co 3 0„ Seat 0 2680 Pocket 12'-0' 22680inl Header at 96'"L-1 Glass on 42" Tall Wall 3'-3' 3' N 8" Cafe 9'-4" CeilingODA T-8"" 5'-0" o I 25 L-1 s.h, 25 s.h. 25L-1Temp. s.h. 4"" ❑' cc .. FL-]5 20'-0" ❑' ❑' °' I 4" ° p�1'-5_rT-4"at 400'" 4' 11Header 96" o x 72"" � Tub Tub Unit 9'-4" Cing. itlu� -------------- h 1 II Bdrm. 2 9'-4" Ceiling ° ' i ' 28f10 10 0 o � P. 9,_4„ co Cing. Q � do o Range & Exh. Hood VTR I ;n Walf Oven d.w. i I ( � I I I ❑I; i I i I' 12„ Kitchen 9'-4 Ceiling Ref Header water at 96- nein Family 11'-4" Ceiling o � 5'-8'" 12" Header at 96" ---------- i o F. "Pocket9'-4 Cing. �6Cing2680 T-6- 8'-6" 26 ° o 00 N �I n M r Header M 1 I at 96" D o I 2080 P Lry�gp 2880 Pock 00 9'-49'-4- 2880 o o v.t.w. Lnd. 9'-4"" w. Cing. I . ❑ 0 o Bollard Rl1 batt insul. adi. walls — A H U� Attic En n T-8" o N � o No --- — 1'-6"' 3' 0' 1 8" 9'-8" IT-0- 12 12'-0_ N T-8"" 2'-0"' 8-4- T-6""5'-6-fZ-8- 1'-8-il I I I I > 0 N 22.5 x 54 Attic Access with Ladder `� Header I at 96" II Dining 9'-4" Ceiling I 11100 v Bdrm. 4 9'-4 Ceiling ° n o mN 1 p (] 0 00 L-4 1 8 23 8"' o L-1 -- Bdrm. 3 9'-4" Ceiling o .. o a o •• [ill 0 8" I 26 s.h. 26 s.h. -- -- 26 es Egress E. 9'-4" Ceiling from FFE 26 s.h. L-1 Egress I -1 ❑ 0 o Garage 9'-4" Ceiling - _- ---- ---� - =- �_ 0 from FFE 12'-0'" 8" L-9 L-9 8" 0 0 0 0do do 26 L-1 s.h. o 0 0 0 Ell01 ❑26 L-1 s.h. 26 s.h. Egress L-1 5'-9'" 6'-9- 6'_9„ 1'-8- 2'-5' 4'-2„ 2'-5'" 1'-8" T-6" 3'-6""- 2'-5'" 4'-2'" 2'-5'" 1'-8" 11'-6- 13'-6- 12'-4" T-0" 12'-4" 6'-8" T-8" 25-0" 31'-8- IT-4- floor Plan Scale: 1/4" = 1'-0" Project Data Design Loads . U Project Name: Robert Hall Roof Live Load: 20.0 p.s.f. Street Address: 12793 W Angle Rd. Wind Speed: 160 MPH ~ City: Ft. Pierce Wind Importance Factor: 1.0CLN County: St. Lucie Building Category: 11 00 State: Florida Wind Exposure: C 0 rn Internal Pressure Coefficent:.18 Z co Structure Designed: Enclosed 0 0 _J U-) Scope of Work Soil bearing capacity: 2000 p.s.f. -- New One level CBS Area Tabulation 7 w o LO oo O0 M Single Family residence Living: 2656 Q J li CN Building Code Garage: 625 _ Q `° Porch: 304 to l— _M L-7 2020 Florida Building Code: Residential Entry: 213 UJ n 2017 National Electrical Code: NFPA 70 (� w > O Total: 3798 V Building Data' W o Occupancy Type: Group R Total Cubic Volume: 25,726.4 c.f. N M Construction Type: V N Number of Stories: One 4-J Project Area: 3798 s.f. (n Climatic & Geographic Design Criteria CU 25 s.h. Weathering: Negligible Termite Area: Very Heavy Egress F- ; L_1 Flame Spread Index & Smoke Developed Index w Insulation Flame Spread: Not to exceed 25 \cci / ~ .� ,�, N Insulation Smoke Developed Index: Not to exceed 450 _ O W Wall Finishes: Not greater than 200 U O O z 00 25 Ceiling Finishes: Not greater than 200 Q LU (� N r s.h. Egress M 00 L-1 c") r- Cast Crete Lintel Schedule All Rebar to be #5 Grade 60 min. CD 0 I I io L-2 0 ZN H34 s.h. Safety Glass in in H34 s.h. HB T bd MARK LENGTH OF LINTEL ALLOWABLE GRAVITY LOAD APPLIED GRAVITY LOAD ALLOWABLE UPLIFT LOAD APPLIED UPLIFT LOAD BEAM SPECS. L-1 4'-6- 6113 1580 2724 550 8F16 16/1T L-2 T-8" 6113 408 3079 70 8F16 1B/1T L-3 1T-4" 1326 855 732 430 8F20 IB/2T L-4 8'-4- 1568 1322 931 478 569 8RF14 1B/1T 8RF14 1B/1T L-5 T-6" 2459 860 1462 L-6 4'-4" 5206 320 2635 105 8RF14 1B/1T L-7 3'-8" 6113 250 3079 100 8F16 16/1T L-8 16'-0" 950 252 404 277 8F16 1B/2T L-9 11'-4" 1366 173 798 33 8F16 1B/1T L-10 10'-4" 1 1533 173 914 33 8F16 1B/17T Min. Beam depths shown, beams may be increased without comment At Lintels over 24 deep provide (1) #4 vertical rebar tied to Horiz. steel at 24"o.c. along length of lintel Narmy d Ps r bar 8F16-1 BAT rmi q4�a: �a�nv a, as� Lintel Type Designation Safe Load Table Notes 1. All values based on minimum 4" nominal bearing. Exception: Safe loads for unfilled U lintels must be reduced by 20% if bearing length is less than 6 1 /2" 2. N.R. = Not Rated 3. Safe loads are superimposed allowable loads. 4. One #7 raper may be substituted for two #5 rebar in 8 inch U lintels only. 5. All safe loads in units of pounds per linier foot. 6. All safe loads are based on simply supported span. 7. Safe load ratings based on rational design analysis per ACI 318 and ACI 530. Composite U Lintel Materials 1. Grout per ASTM 0476 fg=3000 psi with maximum 3/8 inch aggregate and 8 to 11 inch slump. 2. Reber per ASTM A615 Grade 60 3. Concrete masonry units (CMU) per ASTM 090 with minimum net area compressive strength = 1900 psi 4. Mortar per ASTM C270 Type M or S Installation Notes 1. Installation of U lintels must comply with architectural and/or structural drawings. 2. U lintels can be field cut to the required length. 3. Cast in place concrete may be provided in composite U lintel in lieu of concrete masonry units. 4. The exterior surface of U lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 5. Concrete masonry units used in composite U lintel shall be laid in a running bond. 6. Shore composite lintels as required. 7. U lintels are manufactured with a 5 1/2" long notch at both ends to accomodate vertical cell reinforcing and grout. 4VIEWMPII CE° CODE CO ST• �uCIE COIDNT`t BOCC w U Z uJ � � L w li , J C0 U Q 71 J U_ A_ 0 w J Z drawn s.l. checked $1 date 1/42/22 scale as noted job number 21074 sheet A-1 as I in O cn 0 T M T 'v 0) T u'v 0 I co 4" 2500# conc. pad 70'-0" 24'-0- IT-8- 23'-4" 10'-0_ 5'-0- 4'-8" 3'-10" T-8"' 4'-10"' 2'-6"' 3'-10" T-10" 2'-6" V-4" 6'-10" 4'-0- T-10" T-10" 3 _6^ 3 _y" 4'-0" 15" 1'-4' p O O F-1 1 I O I O 16" 2'-6"' — — 1 28- x 28" x 18" F-1 0 ❑ ❑ ❑ ❑ ❑ ❑ Pad Ftng. with (1) #5 rebar 6""o.c. I ❑ F-1 F-1 ❑ ' Each Way 8r11 --m ----- ------ -- -- -- �F-1 -Ell ❑ O O O Fk1 2 L o O— 1 —o — 30" x 30" x 18 —F-1 — —4 ' °' F-1 Pad Ftng. with a v 1 1 (1) #5 rebar 6"o.c. Each Way 1 T T XFT •,e ❑ I F-214'-0"' 5'-4'" 12'-2" 5'-10"' -4" I 1 Ell I Lao------•. 1-2 0-- ----- �- 11 F-3 -- 1 o I I I 8" T-0" 1 Ir 1 I Iio1 0 4 I I F-1 M ( t o F-11 N I bo 4" 3000# FIBERMIX CONC. OVER .006 VAPOR BARRIER 1 ON CLEAN, COMPACTED, TERMITE TREATED FILL O — — — — — — — F-3 — — — — — — — — ASSUMED F.F.E. 0.00' F-4 43 24" x 24" x 18'" Pad Ftng. with I I01 p (1) #5 rebar 6"o.c. Each Way 1 I � 8"' 22'-6"' 12" 1 ( I' Slope 2"_ I 4F13 Slope for Garage Dr. I 30" x 30" x 18" Pad Ftng with — — — — — 1 F-2 � (1) #5 rebar 6"o.c. � 1 Each Way I J L-- -----JF-2 -4" F-2L-------- F-1 N I— o o F-2 .. [nil o M o o .. F-2 o r o 28 x 28" x 18" 1 0 0 Pad Ftng, with (1) #5 rebar 6 "o.c. 14"' o 0 L Each Way 2„ $^ N to r F-2I 24'" x 24" x 18"' I co ' Pad Ftng. with F�4 (1)#5rebar 6"o.c. — — — — — — — — — — — — — — -- — — ❑ F7Each Way I M— p F-5 p F-5 F-5 0— p 1 14 ----F-4 ---11 I O 0 0 OF4 00�-- F-1I --- __ F-4 — —J c' Concrete Steps ---- --- F-1 rol 5011 IF±110 4'-10" V-84' 4'-0- 12'-4"' 4'-0- 111 1'-8 , 1'-8 '1 4'-0- 4'-0" 1'-8" T-0'" 12'-4" IRRI o 4'-9" T-10" 4'-9"' a T-10" T-10" T-10" 4'-10" T-10'" 1 V-6"' 13'-6" 25'-0" 31'-8" IT-4- Foundation & Footing Plan Scale: 1/4" = V-0' SOIL STATEMENT: Foundation has been designed for a soil bearing capacity of 2000 p.s.i. Fill shall be laid in layers of 6". Each layer to be compacted to 95% compaction. If the contractor encounters, while digging the foundation, any discrepancy to suggest the soil may be inadecuate, he must immediately report it to the owner and the Architect or Engineer so as to order a soil boring test. Dowel Rod Repair Note In the event vertical steel has been omitted from the down pour locations, drill 5" into concrete (no closer than 3 3/4" from edges and 5' from ends of cap walls) Remove dust per manufacturers instructions and use Two part epoxy to anchor the #5 rebar in place. Use either "Hilti C-100" or Simpson Epoxy -Tie. FORMWORK & SHORING �M a Cn ih No structural concrete shall be stripped until it has reached at least 80% of the 28 day design strength. Design, Erection, & Removal of all formwork, shores, & reshores shall meet the ACI Standards 347 and 301 Contractor to verify all building setbacks prior to the start of constructic)n. A formboard survey shall be submitted to the building department for approval prior to pouring concrete. F-1 F-3 18" x 18" mono. footing 8" x 8" thick edge with (2) #5 rebar cont. with (1) #5 rebar cont. 4 4 4" 13" 4 8„ 18 ; MONO. EDGE FOOTING EDGE FOOTING F-2 F-4 18" x 18'" mono. footing with (2) #5 rebar cont. 18" x 18" mono. footing with (2) #5 rebar cont. 8", 4- 4"" 4"" slope 4"— 4„ 14' 14" 18" STEP FOOTING CURB FOOTING v F.F.E slope #5 Rebar 12-o.o-. #5 Rebar Typ. Typ. Nosing 10"' 1" Typ. Cast In Place conc. Steps with 3000# mix v W Conc. Step Detail Entry 100.0 F.F.E. _ 'v (2) #5 Top (2) #5 Middle (2) #5 Bottom F-5 1 $e Riser Hght. not to exceed 7 3/4" r -25" #3 Vert. 16"o.c. Driveway - -25- GENERAL FOUNDATION NOTES Concrete shall be a minimum of 4" thick over clean, compacted, termite treated fill and 6 mil polyethylene vapor barrier. If concrete slab contains 6- x 6- 10/10 VVWM provide 1- coverage Concrete shall have at minimum compressive strength of not less than 3,000 p.s.i. All 90% hooks are to be extended 10" minimum beyond the turn. Field bends are to be done cold and the diameter of the bend, measured on the inside of the bar, is not to be less than six bar diameters. Minimum coverage for rebar shall be 3" in footings and 1 1/2- in bond beams. Hooks may be rotated horizonitally if required to achieve minimum coverages. Rebar overlap shall be 48 bar diameters. 30" for #5 rebar The foundation design assumes that the soil has a minimum load carrying capacity of 2000 p.s.f. In the event the soil bearing capacity falls below 2000 p.s.f. This foundation plan may be superceded by Foundation Design Engineer. Satisfactory compaction test of fill does not verify lower soils are adequate. All specifications and dimensions to be verified by contractor. All exterior slabs shall slope a minimum 1 /8" per foot for drainage U e®® 0 w 00 M �R V z M C) _J to bb N W (1 i I . N a) a co r N Q -I U� 4 r v • Vi F- z U N a N (� U_ LU O 1 N w k, W U LUQ r rn f4 'C uo � N = O T r O Z co IX N �/ Q LU N r v � � M ..1.. T W z LLJ 0 �tll;m :'. 0 c� 4� s a J Q � +j 00 LU 0 z drawn 61 checked A. date 1/12/22 scale as noted job number 21074 sheet A-2 LL_ III LL�'111 � it Rear Elevation Scale: 1/4- = V-0" Two Coat Stucco over CBS block 27" x 27" ""Blacked Weep Skreed Product Approval Affidavit Form Category Subcategory Approval Numbers Manufacturer Model Number Glass Type Attachment Method Building Design Product Rated Pressures Design Pressures EXTERIOR DOORS Head & Sill: 6- from corners. Jambs: 6" from corners and Swinging FL#: 17184.17 Plastpro Fiberglass Impact 14"o.c. max. Use 1/4" dia.Tapcons with 1 1/4" embedment in +33.5 -36.3 +50.0 -55.0 concrete Swinging (French) FL#: 17184.2 Plastpro Fiberglass Impact Head: 4" from corners & 51" & 9" from center. Jambs: 4" from corners and 18.5`o.c. max. Use 1/4" dia. Tapcons with +33.5 -36.3 +50.0 -55.0 1 1/4- embedment in concrete Garage Overhead FL#: 15371.2 DAB Door Company Hurricane Master 824/811 N.A. - - Flag Bracket Angle (3) total 5/16x 1 5/8la g screws. (7) total +27.9 -31.2 +36.0 -44.0 Bracket T-0"" height (1) 5/16"" x 1 5/8` lag screws per bracket. WINDOWS Head & Sill: 6" from corners and 15`o.c. Jambs: 6- from Singlehung FL#: 239.2 PGT 5500 Impact corners and 14" o.c. Max. 4" from meeting rail. +33.5 -44.8 +50 / -50 Use 3/16" Tapcon with 1 1/4" embed. into concrete Head & Sill: 6" from corners and 8"o.c. Jambs: 6- from Fixed FL#: 243.5 PGT 5520 Impact corners and 8' o.c. Use 3/16" Tapcon with 1 3/4- +33.5 -36.3 +/- 70.0 embeded into concrete ROOFING PRODUCTS 5V Crimp Roofing FL#: 17443.1 JA Taylor 5V Crimp #9-15 or #10-14 x 2- Long wood screw with washer at -57.5 -69.25 each Rib 16""o.c. Underlayment FL#: 9777.7 Owens Corning Weat Specialtycialty Direct Attachent to plywood SIDING FL#: 13192.2 James Hardie Hardie Plank Fasteners shall be ET&F block nail .30 Head dia..14 Shank dia. and 1 1/4- long. 21-o.c. maK, -50.0 -92.0 Impact Shutters Two Coat Stucco Finish over paper backed wire lath over House Wrap over 19/32" c.d.x. plywood fastened as per Nailing Schedule PLUMBING NOTES: 5V Metal Panels over Peel & Stick underlayment on 22'-0" 19/32"c.d.x. plywood fastened as per nailing schedule Pre Engineered Wood Roof Trusses 24-o.c. Shop Drawings by Others See Connector /-Schedule U 12 Galy. Drip Edge Spray Foam ��aries over 1 x 3 p.t. Insulation � r / 9'-4- 2 x 8 R.S. Pine 1 x 4 p.t. Fascia Board Firestop Stucco Soffit Over Two Course Perimeter High Ribbed Wire Beam with (1) #5 Rebar Lath in each course, Filled Install one layer of 15# with Grout felt to framing prior to installing wire lath 1 x 2 p.t. furring 8 x 16 x 8 0.00, strips 24"o.c CMU Typ. with R4.1 Foil insulation Light Textured 1/2r' d. . Stucco Finish #5 Vert. rebar in I Lap Siding Look grout filled cell Stucco Pattern on See Floor Plan Front Elevation for Locations 6 1/2„ Exposure I 4" 3000# Fibermix Conc. #5 Vert. Reber with on .006 Vapor Bearier on i ( 10�" Hook and 30- Clean, Compacted, Termite ! Lap. Tie to Vert. Treated Fill Rebar In Cells a J 0 M i I I 0.00' F.F.E. Grade Plumber to consult with contractor and equipment ordered for rough in dimensions. Verify all dimensions with the floor plan. The floor plan dimensions dictates all other dimensions on other sheets. Do not scale drawings, if any conflicts arise, contact the Architect or Engineer for clarification prior to construction. All sanitary lines 2- or less shall have a slope of 1/4- per foot minimum. All sanitary lines above 2- shall have a slope of 1/8- per foot minimum. Provide Anti -Scalding Valve in all showers Lowest living area floor elevation (refered as 0.00') to be set by a professional land surveyor to the required building department elevation, but not less than 18- above the crown of the road. (2) #5 Rebar 1'-6- o Typical Wall Section SINK 2" AUTO VENT SINK 2- v.t.r. v.t.r. 2„ v.t.r. 2" LAV2"v.t.r. I .11 LAV LAV 3"" e W.C. 2" 2 rue lI w.c. U SHWR 3 2„ 3"" 3„ 4„ c.o. 4„ Plumbing contractor to provide a water hammer & shut off valve at each fixture Insulate all hot waterlines Plumbing Riser Diagram to sewer system V C r=-r Q rr 00 O LLJ M z C7 _1 CD U- co _ wt 'N LLJ i I L0 CI d o (D ® J LiJ ^ 04 Q r v • _ I � co v z o- EE (� LL, ' O .J N LO Lu O rn VJ ICU iv U Lu Q LO El LO r h 00 O Zry i jr Q w 00 LLI z LU o :^ UJ :0 c U J Q L J LL Z w J c� z D" drawn .J. checked s.l. date I / 2/22 scale as noted job number 21074 sheet A-3 Left Elevation Scale: 1 /4- = 1'-0- Hardie Plank Siding over House Wrap over 19/32" Roof Plan Scale: 1/8" = 1'-0" 4' Right Elevation Scale: 1 /4"" = 1'-0" Wind Zone - Roof Plan Wind Zones - Walls U C. 00 M W M �J Z J tc) C7 LL cn W N U L Ids W 0)W Q .N N .V' Q N v U Z a o U W > J N LO 0 W 0') > N U) W < 1h^ LO U o Cz 00 r o Z I N _ Q r` 00 �co L.L M T W U Z W 0 m � z LL1 ILL i 0 U Q LL L � J N +) W J 0 Z 7W drawn S.I. checked ..I. date 1/22/21 scale as noted job number 21074 sheet A-4 Connector Schedule Truss Bearing Truss Connector C"ty' Connector Fasteners Point Uplift ID Uplift HETA20 1 1810 (8) 10d x 3 1/2" A01 GE 39 2544 (7) 10d x 1 1/2-to 2 Ply MTSM16 1 830 Truss & (4) 1/4-x 2 1/4- Titen 2 screws to CBS HETA20 1 1810 (8) 10d x 3 1/2- A06 17 2646 (8) 10d x 1 1/2-to 1 Ply HTSM16 1 1110 Truss & (4) 1/4-x 2 1/4- Titan 2 screws to CBS HETA20 1 1810 (8) 10d x 3 1/2- A07 17 2414 (7) 10d x 1 1/2-to 1 Ply MTSM16 1 830 Truss & (4) 1/4`x 2 1/4" Titen 2 screws to CBS 10 5359 (1) 5/8- ATR Drill & B03GR MGT 2 7930 Epoxy with 12" min. Embed. & (22) 10d 3 Ply 17 4876 to Truss T YP• each fastener 10 5098 (1) 5/8- ATR Drill & Epoxy with 12" min. D04GR MGT 2 7930 Embed. & (22) 10d 3 Ply 17 4944 to Truss Typ. each fastener K04GR 7 2011 HETA24 2 2365 02) 16d x 3 1/2" 2 Ply All Other Trusses Each <1810 HETA20 1 1810 (8) 10d x 3 1/2- to CBS Brng. All Other Trusses Each <990 MTS16 1 990# (9) 10d x 1 1/2" Brng to Frame Valley Supporting Framing (4) 10d TYUSSOS <250# VTCR 1 370# Valley (3) 10d x 1 1 /2 Truss Connector Notes: Do not substitute connectors Do not sheath trusses before all straps are in place Attach valley trusses and piggy back trusses, if present, to main trusses per truss manufacturer drawing. Truss to truss connection by truss company, installed per manufacturers spec's. Lateral forces perpendicular and parallel to wall has been considered (less than 300 p.l.f.) Contractor to approve temporary bracing to prevent toppling of trusses, see HIB-9. Other specs, if different from above, have priority. A.T.R. = All Treaded Rod Drill and Epoxy Set all A.T.R. Use either "Hilti- C-100 or Simpson Epoxy Tie Epoxy Provide equal number of studs under girders equal to the number of plys. 2 x 4 blocking at 4'-O "o.c. starting from ridge between both top and bottom cords for two truss spaces from gable end See truss shop drawings (2) 1 Missed Tie Down Strap Note In the event the Tie Down Strap has been omitted from the Layout location, install one HTSM20 strap at the proper location Fasten with (4) 1/4" x 2 1/4" Hex Head Titan screw to C.B.S. and (10) 10d to truss. MAXIMUM UPLIFT 1175 lbs. 2 x 4 diagonal „X„ bracing at 8'-O"o.c. starting from ridge with (3) 12d each end -\ Continuous 2 x 4 Lateral bracing at 1/3 points of span. Nail with (2) 16d each truss btm. cord trusses 24" see layout Continuous 2 x 4 bracing fastened to beam with 5/8" x 6- wedge bolts with 1/8" x 2" washer 24"o.c. Fi cr-„ racin I_Jetc-N Galv. drip edge min. 4" lap 1 x 3 p.t. over 2 x 6 Paint Grade Fascia Gable end truss by truss mfgr. 19/32- c.d.x. plywood with 8d nails 4"o.c. Cover with House Wrap 2x „L„ web stiffener as required by the truss mfgr. "Simpson" HETA16 truss to bond beam with (14) 10d x 1 1/2- located at each truss vertical Concrete Bond Beam Scale: 1/4" = V-0" A ttic; "gents rculation ENTRY, PORCH, and GARAGE Attic Area: 1142 s.f. / 150 = 7.6 s.f. required. soffit area = 94.0 I.f. x 1.3 = 122.2 s.f. Venting Provided: 8 x 16 soffit vent: 85 sq. in. each vent 14 Vents along overhang = 1,190 sq. in. 1,190 sq. in. / 144 = 8.2 s.f. Total Ventilation Provided: 8.2 sq. ft. I I -t l✓L V. j9`4°' PT. IT. U i.i 00 M W co �i_ V Z J Lo a LL C'0 W u7 •(D W L. y op N J .N Q � v U d Z L O U W > O W M ^' W '4-) v ) fi ~ 9 010 W ~ N U T O 00 O z �a Nv � o0 M r W U Z W N _ W U- X . -i >� 4-+ U" U Q 3 W J Z A drawn $1 checked s.l. date 1/12/22 scale as noted job number 21074 sheet A-5 Ceramic Tile Shall be installed in accordance with ANSI A108.1, A108.4, A108.5 A108.6, A108.11, Al18.1, A118.3, A136.1, & A137.1. Fiber mat reinforced backer shall be used behind wall applied ceramic tiles in the tub and shower areas and conform to ASTM C1325. Per Durock, cement board exceeds ASTM C1325. Gypsum Note Gypsum board shall conform to ASTM C22, C475, 0514, C1002, C1047 C1177, C1178, C1278, C1396, or C1658 and installed per FBC residential code. Per USG, Wallboard conforms to C1396. Gypsum Board & Gypsum Panel Products Gypsum board and gypsum panel products shall be applied at right angles or parallel to framing members. All edges and ends of gypsum board and gypsum panel products shall occur on framing members, except those edges and ends that are perpendicular to the framing members. Interior gypsum board shall not be installed where it is directly exposed to weather or to water. Wall and ceiling gypsum board shall be fastened with screws spaced at 12""o,c. Screws for attaching gypsum board and gypsum panel products to wood framing shall be Type W or Type S in accordance with ASTM C1002 andshall penetrate thewood not less than 5/8"" inch (15.9mm) Gypsum board and Gypsum panel products shall be attached to cold formed steel framing less than 0.033"" (1mm) thick shall be Type S in accordance with ASTM C1002 or bugle head style in accordance with ASTM C1513 and shall penetrate the steel not less than 3/8" to 0.112" 0mm to 3mm) thick shall be in accordance with ASTM 0954 or bugle head style in accordance with ASTM 1513. Screws for attaching gypsum board or gypsum panel products to structural insulated panles shall penetrate the wood structural panle facing not less than 7/16"o.c. (11.1mm). Gypsum board used as the base orbacker for adhesive application of ceramic tile or other required nonabsorbent finish material shall conform to ASTM C1396, C1178, 01278. Use of water resistant gypsum backing board shall be permitted on ceilings. Water resistant gypsum board shall not be installed over a Class 1 or Class 2 vapor retarder in a shower or tub compartment. Cut or exposed edges, including those at wall intersections, shall be sealed as recommended by the manufactuer. Water resistant gypsum backing board shall not be used where there will be direct exposure to water, or areas subject to continuous high humidity. Cold Formed Steel Note Cold formed steel framing supporting gypsum board and gypsum panel products shall be not less than 1 1/4" (32mm) wide in the least dimension. Non Load bearing cold formed steel framing shall comply with AISI S220 and ASTM C645, Section 10. Load bearing cold formed steel framing shall comply with AISI S200 and ASTM C955, Section 8. Wood Framing Note Wood framing supporting gypsum board and gypsum panel products shall be not less than 2"" (51mm) nominal thickness in th least dimension except that wood furring strips not less than I" by 2" (25mm x 51 mm) nominal dimension shall be permitted to be used over solid backing or framing spaced not more than 24"o.c. (610mm) Wire Lath /attachment Over wood framing the paper backed wire lath shall be installed over one layer of approved plastic house wrap. Lath shall be attached horizontal framing members with 1.5" roofing nails and to vertical wood framing members with 6d common nails or 1 "" roofing nails driven to penetration of not less then 3/4" of an inch, or 1 " wire staples driven flush with the plaster base. Staples shall have crowns not less than 3/4"x and shall engage not less than three strands of lath and penetrate the wood framing members not less than 3/4". The fasteners must penetrate the wood framing members not less than 3/4 Fasteners shall be 7"r o.c. max. 2- dia. Pipe Set ballai from app Galy. Cc (4) 1/4" x 2 1/. Tapcons Cap ypical Conic. roundation Bollard Detail 2 x 4 bottom cord bracing Bottom Cord Lateral Bracing 8" x 16" C.M.U. WITH CELLS FILLED ..... WITH GROUT & (1) #5 VERT, ..'.r.'�.. DOWEL P.T. 2 x 6 AT O 3 SIDES OF 3 OPENING, FASTEN TO BLOCK AS NOTED. x DOOR SIDES 1/2" x 6" REDHEADS WITH MIN. 2- x 1/8-WASHER 12" FROM ENDS AND 24"o.c. MAX. DOOR HEAD 1/4- x 2 3/4- TAPCONS STAGGERED O 24"o.c, cr o OR 5/8- x 6- Redheads with Min. 2- x 1/8" washer 12" from ends and 28"o.c. max. OR 1/4" x 1 1/4" min. embedment spaced at 7 1/2"o.c. with I" O.D. washers spaced bottom anchor at 3 1 /2- from bottom of 2 x 6 and top anchor at least as high as the door opening. Garage Door Buck Detail Alum. window frame 3/8"" continuous bead of caulk (back bedding) behind shim to prevent liquid passage 1/4" struct. shi set flange in continuous bead of caulk across the entire face of buck perimeter caulk stucco finish Gunable sealants shall comply with ASTM C 920 Class 25 grade or greater for proper joint expansion and contraction precast cone. sill corrosive resistant Tapcon concrete srews installed as specified in window manufacturers product approval rwirdow sill Typical Precast Conc. Sill Detail 3/8"" continuous bead of caulk (back bedding) behind buck to prevent liquid passage set flange in continuous bead of caulk across the entire face of buck Treat the Masonry opening Jambs, Head, & Sill with LWM200 Liquid Applied Waterproofing--\ 00 M CBS Min, 1 1/4"" embedment ° v at windows and min. ° ° 1 1/2" embedment at Q a ° ° sl. gl. doors a a ° 1/2" drywall stucco finish perimeter caulk Attach p.t. bucks J with 8d coil nails at 12"o.c. Typ. Alum. window . jamb or sliding glass doorjamb 1/4" max. struct. shim caulk attach as per manufacturers product approvals NOTE: Method of attachment and Gunable sealants shall comply with waterproofing procedures are the ASTM C 920 Class 25 grade or same at poured concrete sill. greater for proper joint expansion and contraction Coat Bucks with LWM200 Waterproofing after they have been installed and Chaulked Window & Door Flashing Detail at CBS Wall Includes Buck Attachment Method STEP 3 Apply Horizontal Peel & Stick Fashing over — Flange. Extend flashing back full width of framing Window Flange Secured to wood framing as per manufacturers recomen- dations TYVEK Building Wrap at wood frame locations STEP 2 Apply Vertical Peel & Stick Fashing over — Flange. Extend flashing back full width of framing GENERAL ROOFING NOTES Roofing to be composed of and attached to pre manufactured wood trusses as follows: Felt underlayment (min. ASTM 0 226 Type II) with 4- min. side and end laps, fasten with coorosion resistant annular ring shank nails at 6-o.c. in laps and in staggered rows spaced 12""o.c. in field. If roof pitch is < 4/12 install (2) layers 15# felt. If roof pitch is 4/12 or greater, install (1) layer 30# felt. 19/32- plywd. sheathing or equal installed with staggered joints & GI clips, nailed to trusses with 8d corrosion resistant annular ring shank nails spaced max. 6"o.c. throughout, except max. 4-o.c. at gable ends. All roof trusses are to be pre -manufactured assemblies provided by a licensed wood truss fabricator with separate drawings and data prepared for actual project conditions by a Florida registered professional engineer certified for truss design. Any deviation from the proposed plans as shown regarding placement or bearing shall be brought to the attention of the truss engineer prior to fabrication of the trusses. The truss manufacturer's certified layout shall govern after fabrication. The handling, erection, and fixing of wood trusses shall be in accordance with the specifications contained on the certified mfgr's. drawings and data. All engineered headers and truss hangers to be provided by the truss manufacturer. Splitting or cracking of structural components due to installation of hardware is not permitted. Unless otherwise noted, the installation of specified hardware shall conform to the truss manufacturers installation instructions and standard practice. BUCK ATTACHMENT NOTES AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH BUCKS TO BLOCK WITH 1/4" DIA. TAPCONS WITH 1 1/4" EMBEDMENT INTO C.B.S. SET A 6" FROM CORNERS AND AT 12"o.c. MAX. AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS OR ""T" NAILS" 4- FROM ENDS AND 12-o.c. USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION SHEATHING NAILING NOTES Nailing Pattern Zone 1: 8d at 6"o.c. field & 4"o.c. edges Zone 2R, 2E, 2N: 8d at 4"o.c. edges & field Zone 3R, 3E: 8d at 4"o.c. edges & field Pneumatic Nails Pneumatic or mechanicaly driven nails will be accepted under the following conditions: Min, nails size 8d or larger ring shank with Min. shank diameter:.113 Min. Length: 2- Min. Head Diameter:.280 Full Round Min. Ring Diameter.012 over shank dia. Min. 16 to 20 Rings per Inch Note Gun nails shall be permitted as an acceptable fastener from any manufacturer Wood screws meeting the same size requirement may be used in lieu of nails without comment Nailing Schedule ROOF & FLOOR DIAGRAM Use sheathing with #8 gun nails at 6-o.c. at supported panel edges and #8 gun nails at 6"o.c. at intermediate supports. ROOF SHEATHING TO GABLE END FRAME Use #8 gun nails at 4 "o.c. Wood Frame wall EXTERIOR SHEATHING Use #8 gun nails at 4"o.c. at panel edges c� and #8 gun nails at 4" o.c. at panel top and ........::t-`-i:::;i, bottom and 6" o.c. in field STEP 1 Wood Frame Wall L6- Apply Sill Peel & Stick Fashing over Flange. Extend flashing back full width of framing Frame Wall Window Flashim Wood Frame Wall THRESHOLD NOTE At egress door (see floor plan) the max, hgth. of the threshold shall be 1/2"" corner bars at beam (outside only) (2) corner bars at footing (min.) — vert. dowel lapped with wall reinforcing, all laps 30" (min.) in grout filled cell 0 z 9 all comer bars to be the same size, number, and spacing as horizontial bars in footing, beams, and walls Corner Reinforcing Detail STRUCTURAL NOTES: All reinforcing steel shall be high strength billet steel and shall conform to ASTM A-615 grade 60 specifications. Lap continuous reinforcing 48 bar diameters or 30 in beams and in slabs. Lap bottom steel over supports and top steel at midspan. Hook discontinuous ends of all top bars. Reinforcing steel shall have a minimum of 1 " concrete cover, or as follows: BOTTOM TOP SIDES Beams: 1 1 /2"" 1 1 /2" 1 1/2- Slab on Grade: 1 1/2"" 1"" _ Structural Poured: 3/4"" 3/4"" _ Poured Walls: _ _ 3/4"" Slabs exposed to the weather 3/4"" 1- Reinforcing steel shall be detailed and fabricated in accordance with the ""Manual of Standard Practice of Detailing Reinforcing Concrete Structures"" and the current "ACI Building Code 318"" All structural steel shall conform to current ASTM Specification A-36 All wood in contact with masonry shall be pressure treated or approved seperating material. All dimensions shall be verified in field by the contractor. If there are any discrepancies the Architect or Engineer shall be notified before proceeding. No slump over 5" shall be permitted for any structural concrete without the Architect or Engineer approval. All Design and Construction shall be inaccordance with the current American Concrete Institute (ACI). and the American Institute of Steel Construction (AISC), The Florida Building Code and all applicable local codes. Structural Concrete shall attain a minimum ultimate compressive strength (Fc') in 28 days as follows: Column Footing and Wall Footing: 3000 p.s.i. Column and walls from foundation to roof: see column schedule. All other concrete: 3000 p.s.i. Footing sizes and reinforcing are based on allowable soil bearing capacity of 2000 p.s.i. All footings shall bear in virgin soil. If this is not the case, the Architect or Engineer shall be notified before proceeding with the work. Timber (Heavy Timber Construction) (a) Truss manufacturer shall submit a signed and sealed shop drawings by a registered Engineer. (b) Wood rafters to have a Stress Grade of Fb=1200 p.s.i. (c) Roof members should be secured to the beams or other structural components with hurricane anchors for wind uplift. All wood members shall have a minimum fiber stress in bending of 1200 p.s.i. with 1/360 max. deflection. All bolted connections shall be 1/2"" Cadmium plated or better. Lag bolts to be used only in shear connections with minimum 4" threaded penetration past steel plate. Lag bolted conditions shall be drill tapped no larger than the internal thread diameter and shall not be hammer driven. Under Girder Trusses provide equal number of studs as girder plys at frame bearing locations GENERAL REQUIRLENTS All work to be as per the current edition of the Florida Building Code and meet or exceed all applicable local requirements. General contractor is responsible for all labor, materials, utilities, testing, waste removal, storage, securing of site, accomodation, transport/freight, and all other cost related to the completion of this project., unless explicitly identified here, Owner is responsible for all municipal related charges such as impact fees, and water connection, except building permit fees, which are to be included in the construction bid. General contractor to check all drawings for errors and ommissions and bring them to the attention of the architect prior to starting any work, or ordering any materials of the respective division of work. If such errors and ommissions are not reported in writingto the architect, any resulting damages or costs shall be born entirely by the general contractor. Architect is not responsible for the contractors method or means of construction. General contractor is to keep the Site in a clean and safe state through out the course of construction. On building turnover, general contractor to clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and standard practice. All plans and drawings are not considered complete until they have been reviewed and approved by the St. Lucie County Building Department and the building permit has been issued. EXTERIOR CEILING & SOFFIT NOTE 7/8" Stucco finish over 3/8" high ribbed galv. wire lath fastened to framing members with No. 11 guage nails with 1 3/4" embed. with 3/8" dia. head 6""o.c. max. edges to be tied and nailed at 9""o.c. Provide one layer of 15# felt to framing prior to installing wire lath. INTERIOR WALL FRAMING NOTE Interior non bearing walls to be 2 x 4 studs 24"o.c. Spruce, Pine, Fir (SPF) #2 Grade lumber or better or metal studs (25 Ga.) Crimper may be used in lieu of screws. U 00 M ItT Q. M U- O a; L. LU Z i U D Lo to bb N L Q0 'F QLL LO o^o N Q J C � r- .N Q . U H p CU Z V C) 0 0 N O W M 0 ' O O � vJ N~ > (UuJ Q^ a ~ Ln C4 CU�. TZ �oZ 00 —� w^ NN� Qcu (� L.I. co co r W U Z uI 0 -- (v LLI U p�1 6�A�w U Q J LL 3>® w U) w J 0 Z N drawn s.l. checked s.l. date 1/12/22 scale as noted job number 21074 sheet A-6 Electrical Load Calculations 2656 Living S.F. at 3 VA 7968 watts Two 20 Amp Appliance Ckts. 3000 watts One Laundry Cir. @ 1500 watts 1500 watts One Range 8000 watts One Dishwasher & One Disposal 3000 watts One Microwave @ 2000 watts 2000 watts One Water Heater @ 4.5 kw 4500 watts One Wall Oven 8000 watts One Dryer @ 5 kw 5000 watts One Ref. @ 1500 watts 1500 watts Three Baths @ 1500 watts each 4500 watts Total 48,968 watts First 10 KVA at 100% Remainder at 40% 10,000 watts 15,587 watts Total 25,587 watts One AC Heat at 100% 10.000 watts Total 35,587 watts 35,587 W / 240 V = 148.2 Amps Use 200A Service Smoke detectors wired to 120V Bathroom lights Non Switchable, Non GF1 Electrical contractor to verify all equipment loads prior to start of construction. Electrical contractor to recalculate electrical schedule if loads are to be modified (3) #2/0 (THW) copper and (1) #4 ground (THW) copper in 2 galy. conduit Panel: 200 A.M.C.B. 1200 Amp 1 �d, 3W 40 Circuit Panel olt 120/240 V disc. 5/8"" dia. x 10'-0' � long ground rod 3/4" copper water pipe 8'-0" (3) #2/0 (THW) copper and (1) #4 ground (THW) copper in 2 galy. conduit Wall F.P.L. service [[ma�yy / (if overhead / service) (3) #2/0 (THW) copper and (1) #4 ground (THW) copper in 2 galy. conduit F.P.L. service (if underground service) tie ground wire to footing rebars Electrical Riser Diagram ELECTRICAL LEDGEND jO RECESSED LIGHT WITH LENS 0 EXTERIOR & WET LOCATIONS -E: i- SURFACE MOUNTED LIGHT FIXTURE F----♦--iT� SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE UNDER CABINET FLUORESCENT FIXTURE O RECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN CEILING FAN EXHAUST FAN OUTLET DOOR CHIMES bTHERMOSTAT SD SMOKE & CARBON MONOXIDE DETECTOR $ DUPLEX OUTLET - SWITCHED -I+ TELEVISION DUPLEX OUTLET 220 V OUTLET TELEPHONE -yl- SWITCH PUSH BUTTON �Y THREE WAY SWITCH - DIMMER SWITCH 0 NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46- A.F.F. ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BE AFCI. TAMPER PROOF RECEP-T ICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS Electrical Notes 1. All loads to be checked by a Florida Licensed Electrician 2. All work to meet the National Electrical Code 3. Calculations and panels below are for sizing conduit and overall building load requirements only 4. All conductors to be copper; all insulation to be THHN. Conduit as follows: PVC below ground, Rigid from underground to service box for exterior lights on building, AC, MC, or EMT conduit elsewhere. 5. Ensure min. 36- clear between equipent and disconnects, Typical. 6. Protective ratings shall comply with NEC 110-9 & NEC 110-10 7. Ensure panels have main disconnect at meter pack per NEC 230-70-A-1 To Switch Scale: 1 /4- = V-0"" at Foyer U 00 4.� M ftt M LL O y 1_ LU Z i LO lqf b N a LL cc .N W Q w pC r C N ® J n Q ~ LE(i3 Z U O W —) w o � w CU 0 C) a) O co �!4 ^J VJ co Q) co U w Q rn Lo � N �Uo co00 o Z LLJ �a W� OD T W U Z W m 0 L O W Li_ J a� O C O L.L U Q LL L J w J C7 Z Cn drawn sJ. checked ed. date 1/12/22 scale as noted job number 21074 sheet A-7