Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
wrightsoftDuct System Summary Entire House Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com MAR 0 7 ;?022 S'r. Lucie Project Information For: Robert & Roxanne Hall 12793 W. Angle Road, Fort Pierce, FL 34945 Job: Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.244 in/100ft 0.244 in/100ft Actual air flow 1467 cfm 1467 cfm Total effective length (TEL) 205 ft Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath C 785 35 38 0.249 4.0 Ox 0 VIFx 65.8 135.0 st6 Bath 2 h 3209 123 59 0.280 7.0 Ox 0 VIFx 63.7 115.0 st2 Bath 3 C 785 35 38 0.246 4.0 Ox 0 VI Fx 68.1 135.0 st6 Bedroom 2 C 2884 98 140 0.297 7.0 Ox 0 VIFx 53.5 115.0 st2 Bedroom 3 h 4511 173 95 0.244 8.0 Ox 0 VIFx 70.0 135.0 st6 Bedroom 4 h 2919 112 101 0.321 7.0 Ox 0 VIFx 40.6 115.0 st3 Cate h 3250 125 95 0.344 7.0 Ox0 VIFx 30.4 115.0 stl Dining h 2998 115 102 0.322 7.0 Ox0 VIFx 40.0 115.0 st3 Family Room C 2172 98 105 0.275 7.0 Ox 0 VI Fx 46.8 135.0 st5 Family Room -A C 2172 98 105 0.274 7.0 Ox 0 VIFx 47.6 135.0 st5 Foyer h 1387 53 40 0.335 5.0 Ox0 VIFx 34.4 115.0 st3 Hall 1 C 169 8 8 0.387 4.0 Ox 0 VIFx 14.1 115.0 st4 Kitchen c 3197 20 155 0.339 8.0 Ox 0 VIFx 32.4 115.0 stl Laundry C 1227 41 59 0.385 5.0 Ox 0 VIFx 14.8 115.0 st4 M wlC h 1840 71 43 0.305 6.0 Ox 0 VIFx 28.9 135.0 st7 Master Bath C 1653 52 80 0.316 6.0 Ox 0 VI Fx 23.1 135.0 st7 Master Bedroom C 3107 129 150 0.314 8.0 Ox 0 VIFx 24.5 135.0 st7 Pantry C 83 4 4 *0.395 4.0 Ox 0 VIFx 11.7 115.0 st4 Toilet h 1047 40 31 0.306 4.0 Ox0 VIFx 28.3 135.0 st7 WIC 2 h 466 18 8 0.298 4.0 Ox 0 VIFx 52.8 115.0 st2 WIC 3 h 472 18 9 0.245 4.0 Ox 0 VIFx 68.9 135.0 st6 WIC 4 c 44 2 2 0.321 4.0 Ox 0 VIFx 41.0 115.0 st3 �. '! WCightSOtt" RightSuite®Universal 202222.0.01 RSU08101 ...soft HVAC\Hall Residence -12793 W Angle Rd.rup Calc = MJB Front Door faces: N FILE COPY 2022-Feb-18 18:30:54 Page 1 Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st3 Peak AVF 282 245 0.321 517 10.0 0 x 0 VinlFlx st6 Peak AVF 261 179 0.244 478 10.0 0 x 0 VinlFlx st2 st2 Peak AVF 499 386 0.244 467 14.0 0 x 0 VinlFlx st5 Peak AVF 196 210 0.274 476 9.0 0 x 0 VinlFlx st1 st1 Peak AVF 341 460 0.274 585 12.0 0 x 0 VinIFIX st7 Peak AVF 292 304 0.305 558 10.0 0 x 0 VinlFlx st4 st4 Peak AVF 344 376 0.305 479 12.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL R Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1467 1467 0 0 0 0 Ox 0 VIFx - f- wrightsoft" 2022-Fetr1816:30:54 �.. ....o,., RightSPageuifa@Universal 202222.0.01 RSU08101 2 ...soft HVAC\Hall Residence -12793 W Angle Rd.rup Calc = MJ8 Front Door faces: N -('�- wrightsoit4 Right-M Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com 1 Room name Entire House M WIC 2 Exposed wall 243.9 ft 17.0 ft 3 Room height 9.7 It 9.4 ft heat/cool 4 Room dimensions 1.0 x 92.0 ft 5 Room area 2656.0 ft' 92.0 ft' T y Construction number U-value (Btuhht�° Or HTM I (Btuhlfl') Area fF I or perimeter (ft) Load I (Btu Area ft= I or perimeter (ft) Load I (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S L Heat Cool 6 1A-rflocs 0.900 n 4.20 418 278 111 0 0 0 0 1A-rtov 0.900 n 25.20 9.19 19.79 18 0 454 356 356 0 0 0 0 � 1A-rlov 0.900 n 25.20 19.79 88 0 2218 1741 0 0 0 0 _ D 11D0 _ __. _. _.0.390 - n_ 10.92 _10.34_. 48 _ _ .._4B_..____524 __ _ 496 0_. ___. 0 --- 0.__ __ 0 11 13A-4ocs 0.143 a 4.00 2.19 517 494 1978 1081 75 75 301 165 T 1A-r1ov 0.900 a 25.20 42.33 8 0 202 339 0 0 0 0 1A-r1ov_ - ----0.900 e- --.25.20. _ 42.33 -----15 - ----0 ----_378 -----635 ---- -0 -- --0 - -0 - ......0 -- 13A-4ocs 0.143 s 4.00 2.19 707 532 2129 1163 85 85 339 185 10A-v 0.820 s 22.96 15.21 23 45 520 345 0 0 0 0 10A-v 0.820 s 22.96 15.21 48 96 1102 730 0 0 0 0 1A-rlov 0.900 s 25.20 19.79 60 120 1512 1187 0 0 0 0 .. _. 1A-rlov_._. __ ..__ ____ __0.900 _.s _ ..__25.20 _-_._19.79 _.__.____45 _. __ --90 _ _ _ A134 ___ __891 _ ___. _-0. _ __ _ _0 _ _____.-.0 __ --0 13A-4ocs 1A-r1ov 0.143 0.900 w w 4.00 25.20 2.19 42.33 677 16 631 0 2526 403 1380 677 0 0 0 0 0 0 0 0 to-rlov w- 25.20 - - -- 0 -- -- 756 - 1270 - -- -_0 .. ..0 -- 0- - -0 C _ .. - - 16X19-0md __. -----04900 __..--- 0.408,._ _ -_- 1.59.. ..42.33 __1.37 - -----30 --- 2656___._2656-..._.4211.-_ 3634.__ _ 92._ 92 - .146 _ 126 F _ _. 22A-tpl_ _ _ _ _ 0.989 _ __ _-_-_27.69 . ---, 0.00 ____2656 _,__ ---244 _6755. _0 _-_-_ 92 _ . 17 471 r, -_ ___0 61 c) AED excursion 0 -24 Envelope loss/gain 1 27916 16535 1 1 1256 451 12 a) Infiltration 4209 1127 288 77 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 18 4140 1 230 Appliances/other 4300 0 Subtotal (lines 6 to 13) 32125 26102 1545 758 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 32125 26102 1545 758 15 Duct loads 19% 16% 6142 4199 19% 16% 295 122 Tol room load2673011 36467I 30467I I I 1840 80 843 Avrrequ red (cfm) I I I 711 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -i id- wrlgtn oft 2022-Feb-18 18:30:52 RightSuite®Universal 202222.0.01RSU08101 Page soft HVACkHall Residence -12793 W Angle Rd.rup Calc = MJ8 Front Door faces: N -�- wrightsoft Right-JO Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Toilet Master Bath 2 Exposed wall 8.0 ft 7.0 ft 3 Room height 9.4 ft heattcoal 9.4 ft heat/cool 4 Room dimensions 4.0 x 8.0 ft 1.0 x 158.5 ft 5 Room area 32.0 ft' 158.5 ft' T y Construction U-value Or HTM I Area (ft') I Load I Area (ft)Load I I number (Btuh/ft' ° (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1A-rl ocs 0.1 43900 n 4.20 0 0 0 0 0 0 0 0 1A-rlov 0.900 n 25.20 9.19 19.79 0 0 0 0 0 0 0 .0 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 D 11D0-- _ -- . _- _ .,0.390 _n _ .__.10.92 _._, 10.34 ._--- .. -0 .-- - _0., _--__.-0 ---._ -. _0 _- _ 0 -_ 0 11 13A-4ocs 0.143 a 4.00 2.19 75 67 269 147 66 51 203 111 � IA-rtov 0.900 a 25.20 42.33 8 0 202 339 0 0 0 0 --- - 1A-r1ov------ -- ----0.900 ,.-e.- 25.20 ----42.33 .------0 .. --0 -----0 ------ -O - - -- 15 -------0 ----- - 378 _.. -- 635 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 10A-v 0.820 s 22.96 15.21 0 0 0 0 0 0 0 0 10A-v 0.820 s 22.96 15.21 0 0 0 0 0 0 0 0 1A-rlov 0.900 s 25.20 19.79 0 0 0 0 0 0 0 0 IA-r1ov---- _-_.___-:_._...0.900___s. ._ -25.20 _.,__19.79 ._._._---_-0 _.___.__0__. _-_.__0----_._..0---_.-.-•0_.. .___.0__._. _0 -0. Vtl 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 IA-rlov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 I; CCI lA-rtov 0.900 - w - 25.20 42.33 - 0 - 0 0 - - - - -------- 0 - -- - 0 0 - ._ ..._� .. _. 0- _... -0 - 0 - -- - -- - -- - - -16X19;0md _ - __ - ._ -- - _ -.-. 0.408 - - -_,- -- .. -1.59 _ - __1.37 ._.. _ :. _32 _ 32 _ __- ..__ .51 _ __ 44 . _ 159 - 159 _. - _. _ 251 _- _ _ -21T F- -- 22A-tol-- - - - ----0.989 - - - 27.69 - --0.00 - - -32 - - -_8 -- - 222 -- - -0 -- 159 - 7 -- 194 - - -.0 6 c) AED excursion 1 -31 Envelope loss/gain 743 519 1 1 1027 932 12 a) Infiltration 136 36 119 32 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 879 555 1145 1424 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 879 555 1145 1424 15 Duct loads 19% 16% 168 89 19% 16% 219 229 load 1040I 63 1352 16880 Ar required Q i (�) I I I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -OfF- wrlgtV core- 2022-Feb-1818:30:52 -a RightSuite@Universal 202222.0.01 RSU08101 Page ...soft HVAC1Hall Residence -12793 W Angle Rd.rup Cale = MJ8 Front Door faces: N wrightsaft RighW@ Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcaics@aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Master Bedroom 21.9 ft 9.4 It heat/cool 1.0 x 235.5 It 235.5 ft' Laundry 9.0 ft 9.4 it heat/cool 11.0 x 9.0 it 99.0 ft' Ty Construction number U-value (Btuh/Ft' ° Or I HTM (Btuh/tt') I Area (w) or perimeter (ft) I Load (Btuh) I Area (ft') or perimeter (ft) I Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6- 11 13A flocs 1A rlov 1A rlov Al DO, 13A-4ocs 1A-rlov 1A-0oy---- -- 13A4ocs 10A-v 10A-v 1A-rlov 1A-rlov_. _ ___ _ 13A-4ocs 1A-rlov 1A-rlov ,.16X79Omd-_,-._-_._._ .22A-tDl_ _._._ _Y_._ 0143 0900 0.900 0.143 0.900 ----0.900 0.143 0.820 0.820 0.900 _ _-.__0.900 0.143 0.900 0.900 n n . n_ a a -- e- S. s s s ---s-- w w w 4.00 25.20 25.20 __ 10.92 4.00 25.20 -- --2520 4.00;' '22.96 22.96 25.20 -- 25.20 4.00 25.20 25.20 2.19 19.79 19.79 .,-.10.34 2.19 42.33 --42.33 2.19 16.21 .1521 19.79 -_ 19.79 2.19 42.33 42.33 0 0 0 .....�_.--0.__..._.. 0 0 0 0 0 ,-0 0 0 ---0 111 0 0 30 -___:_ ..0 66 0 0 0 -0 0 _._. ...__0 0 0 -- --0 444 0 0 . 756 _v- _-0 263 0 0 0 0 0. ... _.___,--U 0 0 --r- U 243 0 0 594 _-___ ._..0 144 0 0 0 0 0 _-----._..0 85 0 -�0 0 0 0 0 __-. _ _0 0 0 0 0 0 0 _---__ _ -0 85 0 _- --0 0 0 0 0 __-- ._0 0 0 0 ._ 99 __._ -_.9. 0 0 0 ...__ -_ _:0 339 0 ---- 0. 0 0 0 0 ------_ --0 0 0 0 . 157. _-_249. 0 0 0 __....._ ..0 185 0 --- -0 0 0 0 0. ____-_ _.0 0 0 0 _ . _._.135 ____...0. V)I I;�C; .._ Q. ...._ F_._._.._- --- -6 141 '' 0 0 30 __._,._.:.=_0 66 0 0 ___-_._-0.408 _ - 0.989 _.._- .__� _.-_._1.59 .-_27.69. ___..1.37 - _0.00 ..,__: .236 -- --_236 _._. _.-236 22 .__„._37.3 ---607 -_322 ----0 _._ _99 --_. --99 61 c) AED excursion 1 1 -86 -34 Envelope loss/gain 1 2444 1216 1 1 745 286 12 a) Infiltration b) Room ventilation 373 0 100 0 153 0 41 0 13 Internal gains: Occupants @ 230 Applianceslother 2 460 900 1 230 500 Subtotal (lines 6 to 13) 2817 2676 898 1057 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 19% 16% 0 0 0 2817 539 0 0 0 2676 431 19% 16% 0 0 0 898 172 0 0 0 1057 170 oad Air otal roomequiredl (cfm) I I I 3129I 3150I I I 1041 1 1259I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ' T wrlgftsso>Fe' 2022-Feb-18 18:30:52 ^--+� RightSuite@Universal 202222.0.01 RSU08101 Page ...soft HVAC1Hall Residence - 12793 W Angle Rd.rup Calc = MJ8 Front Door faces: N 1- wrightsoft Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Pantry O ft 9.4 ft heat/cool 9.0 x 6.0 ft 54.0 ft' Hall 1 O ft 9.4 ft heat/cool 1.0 x 110.0 ft 110.0 ft' T y Construction number U-value (Btuh/ft2- Or HTM I (Btuh/ft2) Area fP or perimeter (ft) Load (Btuh) Area ft2 or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 11 - _D -- - _ C _-_ F- - -------------- ._- 1A-r1ovs 1A-rlov 1A-r1ov 11D0__ _._---___.-.0.390__n. 13A4ocs 1A-r1ov IA-rlov.-------- 18A-flocs 10A-v 10A-v 1A-r1ov 1A-r1ov- _.__.---_.._- 13A-flocs 1A-r1ov 1A-r1ov 16X19-0md___..___________0.408_ 22A-tol- - --- - - . .._-------------- 0.900 0.900 0.900 0.143 0.900 -- ---0.900.-e_ 0.143 0.820 0.820, 0.900 -_--.__0.900 0.143 0.900 0.900 ----0.989 n n n a a s s s s -.s.- w w w . _..___.1.59-_ - __ - - -- 4.20 25.20 25.20 _._ 10.92___ 4.00 25.20 - 25.20 4.00 22.96 22.96 25.20 __ 25.20 4.00 25.20 25.20 T 27.69 - ---- 2.19 19.79 19.79 10.34_...__ 2.19 42.33 42.33 2.19 15.21 15.21 " 19.79 - __19.79 2.19 42.33 42.33 _..1.37__54 - _.-0.00 -... --- 0 0, 0 _0----..- 0 0 _------0 0 -0 0 0 -. _ _ - _0 0 0 0 -----54 - -__- -- 0 0 0 -0- 0 0 ----- Q 0 0 0 0 .__ ..._-0 0 0 0 - - -- 0 0 0 __-0 0 0 - ---0 0 0 0 0 _____ __0 0 0 0 _ ._-_86 -- --- - 0 0 0 0 0 0 -----0 -0 0 0 0 ---_----0 0 0 0 - - 0 0 0 _._o 0 0 ------0 0 0 0 0 ___.._.___0 0 0 0 110 --- 110 - 0 0 0 _---.-0_ 0 0 - - - --0 0 0 0 0 . __-__-0.-__- 0 0 0 _-._.110 _-- - --0 - - 0 0 0 0 0 0 - -- -0-- D 0 0 0 -__ 0 0 0 0 _ _ _ 174 - - 0 -- 0 0 0 0, 0 0 - 0 0 0 0 0 0 0 0 '150 -------0 ---___-_54 ----0 __74 - -- 0 - ---0 6 c) AED excursion 1 -2 -5 Envelope loss/gain 1 86 72 1 1 174 146 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 86 72 174 146 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 19% 16% 0 0 0 86 16 0 0 0 72 12 19% 16% 0 0 0 174 33 0 0 0 146 23 Air al room load required. (cm) I I I 104I 84I I I 208 I 168 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -+Fg&- wrlgt02;sotZ- 2022-Feb-1818:30:52 --�-�-�- RightSuite®Universal 202222.0.01 RSU08101 Page ..soft HVAC1Hall Residence -12793 W Angle Rd.rup Cale = MJ8 Front Door faces: N wrightsoft Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Cafe Kitchen 2 Exposed wall 23.0 ft 0 ft 3 Room height 9.4 it heat/cool 9.4 ft heat/cool 4 Room dimensions 14.0 x 9.0 ft 14.0 x 20.0 ft 5 Room area 126.0 ft' 280.0 ft' T Construction U-value Or I HTM Area ft' Load Area fF Load number (Btuhlft;° (Btuh/fl') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 -- - - -- - 1A-rl ocs - - - - 0.900 - n 4.20 - ----- -- 0 -- -- - 0 - 0 0 - - 0 - 0 - 0 -_ e._ .. 0 1A-rlov 0.900 n 25.20 9.19 19.79 0 0 0 0 0 0 01 0 1A-r1ov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 ..._D 11D0-_-------__._-----0.390--a_____10.92_.-_10.34 _.-..-._ 0 __-. 0- -_-_. __ __ _ _ O ..0 0._. ..__.0-_-• -0 11 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 T=13A-4ocs 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 1A-riov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 13A4ocs 0.143 s 4.00 2.19 132 102 407 222 0 0 0 0 10A-v 0.820 s 22.96 15.21 0 0 0 0 0 0 0 0 10A-v 0.820 s 22.96 15.21 0 0 0 0 0 0 '0 0 1A-rlov 0.900 s 25.20 19.79 30 30 756 594 0 0 0 0 1A-rlov_. -- .._ .. --- _ -----0.900 -.-s _ _ _25.20 .__ _.19.79 _- _-._ -0 -- - -_-0 _-._-__. _0 __._. __O ---- ---- _ ._ ___.0 ..___ _-.0 --_-- ___0 yl 13A-4ocs 0.143 w 4.00 2.19 85 85 339 185 0 0 0 0 1A-rlov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 I; -GC -- 1A-r1ov - - - 0.900 - --- - w --- -- 25.20 42.33 - - - -------- 0 - - 0 ----- 0 -- - 0 0 --- - - - -- 0 0 -- - - - 0 - - C - .16X19 Omd _ . 0.408 -- _ 1.59 _ 1.37 _ _ _ 126 _._.. _- .126 - . _ _ _200 _- 172 , .280 _ _-----280 _.. .....44 _ - . _ _ 383 F- . 22A-to1- -- - - - - 0.989 -- =- - -27.69 _....._ .0.00 - - _126 ------------ ------23 - -_ 637 --- - --- 0 - - - 280 6 c) AED excursion -54 -89 Envelope loss/gain 1 23381 111 1 1 444 294 12 a) Infiltration 390 104 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 0 2000 Subtotal (lines 6 to 13) 2728 1684 444 2754 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2728 1684 444 2754 15 Duct loads 19% 16% 522 271 19% 16% 85 443 load3250 19 54 29 5197 3155I ATotair requi d (cfm) I I I 125I 5I I I 20 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -*- wrlgtt�t .afC 2022-Feb-18 18:30:52 --- RightSuite®Universal 202222.0.01 RSU08101 Page ..soft HVAC\Hall Residence - 12793 W Angle Rd.rup Calc = MJ8 Front Door faces: N -- wrightsoftRight-J® Worksheet Job: Entire House Date:, By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Dining 16.0 It 9.4 ft heat/coal 13.0 x 13.0 it 169.0 ft' Foyer 8.0 it 9.4 ft heat/cool 1.0 x 110.0 It 110.0 ft2 T y Construction number U-value (Btuh/ft° Or HT2M I (Btuhlft2) Area (ft) I or perimeter (ft) Load I (Btuh) Area ft' I or perimeter (ft) Load (Btuh) Heat Cool i Gross N/P/S j Heat Cool Gross NIP/S Heat Cool 6 11 D VV C_ _.: 13A-4ocs 1A-r1ov 1A-r1ov 11D0 _ .- -. _ . r _ 13A-4ocs IA-rlov 1A7[1ov---- - - - 13A-4ocs 10A-v 10A-v 1A-r1ov .IA-rlov-...-., .--_---'.n 13A-4ocs 1 A-r1 ov 1A-rlov - --- --- 16X19-0md _ . - 0.143 0.900 0.900 '_ -_- 0.390 0.143 0.900 ---• 0.900 0.143 0.820 0.820 0.900 _-__...0,900-'_s-_. 0.143 0.900 0.900 .------ . -- _ ... 0.408 _-^0.989 n n n _ _n.._ a a _ e_ s s s s w w w ---- _ _ _ __ 4.00 25.20 25.20 _.._-10.92 4.00 25.20 ._ 25.20 4.00 22:96 22.96 25.20 25.20.-_---19.79._.__.---_0 4.00 25.20 25.20 ------ - _ _.1.59 _--_27.69. 2.19 19.79 19.79 _,:10.34 . 2.19 42.33 42.33 2.19 15.21 15.21 19.79 2.19 42.33 42.33 -- - -__ _ _ _1.37 0.00 122 0 44 _-_ _._...0 0 0 -0 0 0 0 0 28 0 -_- -- 0 __ _.:_ 169 _ 169 78 0 0 . ._-_._ ,:0 0 0 -.� ----0 0 0 0 0 .0-__.._.-_._0...._,._--.0_-----.--__0 28 0 0 ----- - ___. _ .-169 16 313 0 1109 _ ...-- _. _0 0 0 - - - 0 0 0 0 0 113 0 0 _____ - __ -- _ 268 ---443 171 0 871 -.-.- ._ - 0 0 0 -----0 75 0 0 __-- _ 48 0 0 ,.. - - ---0 0 0 0 0 0 0 - - - 0 -- --- __110 .�-. 110 27 0 0 _ _ __48 0 0 --•---- -0 0 0, 0 0 _. _ __..,-0_. 0 0 - 0 _ _ _ A 10 _--.-__ -8 109 0 0 _. _- _524 0 0 -------0 0• 0, 0 0 _-.-.__0 0 0 0 ---------0 _. . 174 _ 222. 60 0 0 . -.. _496 0 0 - -- _ 0. 0 0 0 0 0. 0 0 0 -- - - _-..150 _ - - 0 0 0 0 0 62 0 0 -------- _ ._ .._. _231 -- ---__0 61 c) AED excursion 1 -58 23 Envelope loss/gain 2246 1276 1029 683 12 a) Infiltration b) Room ventilation 271 0 73 0 136 0 36 0 13 Internal gains: Occupants @ 230 Appliances/other 2 460 0 0 0 0 Subtotal (lines 6 to 13) 2517 1809 1165 719 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 19% 16% 0 0 0 2517 481 0 0 0 1809 291 19% 16% 0 0 0 1165 223 0 0 0 719 116 Total room load Air required (cfm) 29911 115 2110 102 1387 53 835 40 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. L -Of&- wrlghtsofe- 2022-Feb-1818:30:52 ,A RightSuite®Universal 202222.0.01 RSU08101 Page soft HVAC1Hall Residence - 12793 W Angle Rd.rup Calc = MJB Front Door faces: N wrightsoft' Right-J® Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane. Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Family Room 20.0 ft 11.4 It heat/cool 20.0 x 17.0 It 340.0 f12 Bedroom 4 15.0 ft 9.4 It heat/cool 12.0 x 13.0 It 156.0 ft2 T y Construction number U-value (Btuh/ft2-° Or I HTM (Btu hlft' I Area W or perimeter (ft) Load I (Btuh) I Area fY or perimeter (ft) I Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 ,_- D � - - F - 13A4ocs 1A-r1ov 1A-riov 11DO, .._ -_- .. _._ - 13A-1ocs 1A-r1ov 1A-r1pv.-- 13A-4ocs 10A-v 10A-v 1A-r1ov -lA-cloy_. -.. _----- 13A-4ocs 1A-riov 1A-r1oy - 16X19-Omd . . . ... . . 22A7tol- --- - 0.143 0.900 0.900 .___.. _0.390 0.143 0.900 __0.900 --_ 0.143 0.820 0.820 0.900 --- -----0.900 0.143 0.900 --T0.900 .. .. .11.408 -- -0.989 n n n _ _n_ a a -e-- s s s s _ s- w w _ w ____. _ - 4.00 25.20 25.20 ......10.92 4.00 25.20 .25.20 4.00 22.96 22.96 25.20 ._---25.20 4.00 25.20 _-25.20 _ . __ 1.59 -- 27.69 2.19 19.79 19.79 _. _10.34 2.19 42.33 - 42.33 2.19 15.21 15.21 19.79 .-_--19.79 2.19 42.33 _. _42.33 _ - 1.37 - -- 0.00 0 0 0 -- _ _.....0 0 0 -- -0 228 0 48 0 .---__--.45 0 0 .. ---0 _.: _._ .-340 340 0 0 0 ._ 0 0 0 - - - 0 135 0 48 0 ,-___._45 0 0 -- -� . ___ -. _ _340 -- - 20 0 0 0 _. _ .__.,._ 0 0 0 - --- 541 0 1102 0 _.____1134 0 0 -- - -- 0 _._ . _539 - - 5r'4 0 0 0 -___-- - -. 0 0 0 --- 0 295 0 730 0 ._ .- ..891 0 0 --- ----0 _ . _.__ 465 -- - - 0 113 0 44 _ _ .. 0 28 0 -- --0 0 0 0 0 ____----0 0 0 - - --- _0 _- . _156 -- --156 69 0 0 _ - -- _._._ 0 28 0 --------- -0 0 0 0 0 _ - --_0 0 0 - - - 0 ._ .- _ . 156 --- 15 275 0 1109 _. _ 0. 113 0 --- 0 0 0 0 0 _ ._ . _ __0 0 0 -- -� .. __ __247 - --- 415. 151 0 871 _. -.___ _ _0 62 0 --- --0 0 0 0 0 __ . _ _ -.0 0 0 - - - 0 .. _ _ -21.3 ______0 61 c) AED excursion -120 -57 Envelope loss/gain 3870 2261 1 1 2160 1239 12 a) Infiltration b) Room ventilation 411 0 110 0 254 0 68 0 13 Internal gains: Occupants @ 230 Appliances/other 2 460 900 2 460 0 Subtotal (lines 6 to 13) 4281 3731 2414 1767 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 19% 16% 0 0 13 4294 821 0 0 11 3742 602 19% 16% 0 0 36 2450 468 0 0 30 1798 289 Total room load Air required (cfm) I I 5115 I 1961 4344 210I I 2919 I 112I 2087 101 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlghtsof C 2022-Feb-18 18:30:52 --- RightSuite@Universal 202222.0.01 RSUD8101 Page soft HVAC\Hall Residence - 12793 W Angle Rd.rup Calc = MJ8 Front Door faces: N '�' wrightsoft° Right-JO Worksheet Job: Entire House Bate: By. Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area WIC 4 0 ft 9.4 ft heat/cool 8.0 x 3.0 ft 24.0 ft' Bedroom 2 15.0 ft 9.4 ft heaticool 1.0 x 164.0 It 164.0 ft2 T y Construction number U-value (Btuh/ft2° Or HTM I (Btuh/ft') Area fl? I or perimeter (ft) Load I (Btuh) Area (ft)Load I or perimeter (ft) I (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S j Heat I Cool 6 11 VJ _._.D T-1 -- - --G LL�� F - - 1A rtov 1A rlov 11D0_ .__... :.w_ ., . _ 13A-4ocs 1A-r1ov 1A-r1av - - ---- 13A-46cs 10A-v 10A-v. 1A-rlov, 1A-r.1ov_.w.„ ...__ 13A-4ocs 1A-rlov 1A;r1ov_----- - -- - --- 16X1970rtid'_ - ..- 22A-tol--- 0.143 0:900 0.900 _.:. 0:390 0.143 0.900 - --_0.900 0t143 0.820 0.820 0.900 _ ___._0.900 0.143 0.900 -------0.900 _._ 0.408 _--_ _P.989 n n n __n._ a a e s s s s _.._:--25.20-_-_19:79 w w _w _ __ _-� 4.00 25.20 25.20 _.10.92 4.00 25.20 _.25.20 4.00 22.96 22.96 25.20 4.00 25.20 25.20 ___" 1.59 ----27.69 2:19 19.79 19.79 -_ 10.34 2.19 42.33 -42.33 2.19 1521 15.21 19.79 2.19 42.33 �_- 42.33 -_._0.00---24 0 0 0 __ ._ :. 0 0 0 0 . 0 0 0 0 __. .--,0 0 0 .---------0 24 0 0 0 __ _ .- __. 0 0 0 0 0 0 0 __ .__._ ._ 0 0 0 . - 0 0 0 0 0 .. .._'_.-0-___._o 0 0 0 0 0 0 ._. ___. 0 0 0 - ---0 0 0. 0 0 .0.,___ 0 0 0 0 0 -'-_0 0 0 - -----0 28 0 0 0 0____.____0.._ 113 0 ------30 _..w_ _ 164 ---- 164 0 .0 0 __ _.. ._.0 0 0 ------0 •28 0 0 0 83 0 - ------ 0 - ___.164 1.5 01 0 0 .__---- _ 0' 0 0 ------0 113 0 0 0. __.____0 332 0 --. 756 ,___ .._260, _-_-_415. 0 0' 0 -_.._ __0 0 0 0 0 0 0 0 0 . 0 ,... _.-_24 - ---0 : �.----0 62 0 0 0 ._.----_._0. 181 0 -- ___1270 -"_.224' -_ _- ._ _._.__38 --- -0 -0 _... _ _33 ---_-0 61 c) AED excursion -1 440 Envelope loss/gain 38 32 1 1 1876 2178 12 a) Infiltration b) Room ventilation 0 0 0 0 254 0 68 0 13 Internal gains: Occupants@ 230 Appliances/other 0 0 0 1 230 0 Subtotal (lines 6 to 13) 38 32 2130 2476 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 19% 16% 0 0 8 46 9 0 0 6 38 6 19% 16% 0 0 10 2140 409 0 0 9 2484 400 Total room load Air required cfm) I I I 55I 2 441 2 I I 25501 98 28184 140 Calculations approved by ACCA to meet all requirements. of Manual J 8th Ed. -1'Fi- wragf�o7Pt` 2022-Feb-1818:30:52 ^-w-�-+ Rig htSuite@Universal 202222.0.01RSU08101 Page soft HVAC\Hall Residence - 12793 W Angle Rd.rup Calc = MJ8 Front Door faces: N wrightsoft" Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area WIC 2 4.0 ft 9.4 ft heat/cool 9.0 x 4.0 ft 36.0 ft' Bath 3 6.0 ft 9.4 ft heat/cool 9.0 x 6.0 ft 54.0 ft' T Y Construction number U-value (BtuhlfV ° Or HTM (Btuh/fl') Area ff' ( ) or perimeter (ft) Load (Btuh) Area fl' ( ) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 D y -- V�I l; CCI '1A-r1 ocs. 1A rlov 1A-r1ov 11D0-. , ._.._ _ ._ .- 13A-4ocs 1A-r1ov 1A-rlo,v - --- -- 13A-4ocs 10A-v 10A-v 1A-r1'ov _1A-r1ov-_----0.900_._s_ 13A-4ocs to-rlov 1A-rlov 16X19;0md _-_, 0.900 0;90Q 0.900 --. '0.390'. 0.143 0.900 --.---0.900-e 0.143 0.820, 0.820 0.900 0.143 0.900 0.900 n n, n _n, a a s s s s w w w .- - 4.20 25.20 25.20 -- 10.92 4.00 25.20 ----25.20-- 4.00. 22.96 22.96 25.20 _._25.20_-__19.7.9 4.00 25.20 25.20 _1.59.. 27.69 _ .- -- 2.19 19.79 19.79 _-.•10.34 2.19 42.33 42.33------0---- 2.19 15.21 15.21 19.79 2.19 42.33 42.33 1.37 _,.. _ ... 0 0, 0 __-- -- ___ 0 0 0 0 0 0 0 _,_.0>.-_,,._...,0_---. 38 0 0 . - . _ ,36 0 0 0 _-- ----._-.0 0 0 -0 0 0 0 0 38 0 0 '„-,,- . _36 0 0 0 _ _--- _ 0 0 0 ---------0 0 0 0 0 0_..____._-0 151 0 0 .._.---_ 57 0 0 0 --_ _. - ,-.0 0 0 -----0 0 0 0 0 82 0 0 ._ -,.__ 49 0 0 0 ..v_ --- -0 0 0 ----- 0 0 0 0 0 _n-__0 56 8 0 0 0 0 -_ .---_.__0 0 0 --0- 0 0 0 0 -_----o_-------__0 48 0 0 . _ 54 -_..._. - 0 0 0 _ _ - .0 0 0 ----0 0 0 0 0' 194 202 0 _ 86 - 0 0 0 -•-- ---- 0 0 0 0 0 0 0 __------0. 106 339 0 7_4 ._-0.408,_ ._ _� .. 54 61 c) AED excursion 5 1 1 118 Envelope loss/gain 1 318 127 1 1 647 636 12 a) Infiltration b) Room ventilation 68 0 18 0 102 0 27 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 386 145 749 664 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 19% 16% 0 0 5 391 75 0 0 4 149 24 19% 16% 0 0 15 764 146 0 0 13 677 109 Air I I I 468I 178I I I 935101 785 38I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -via- WWI -go -d ft ' 2022-Feb-1818:30:52 A --�••� RightSuite®Universal 202222.0.01 RSU08101 Page soft HVAC\Hall Residence -12793 W Angle Rd.rup Calc = MJ8 Front Door faces: N -I' - wrightsoft Right-M Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Bath 6.0 It 9.4 R heat/cool 9.0 x 6.0 ft 54.0 ft' WIC 3 4.0 ft 9.4 ft heat/cool 9.0 x 4.0 It 36.0 ft' T y Construction number U-value (Btuh/ft" Or HT M I (Btuh/ft2) Area fP I or perimeter (ft) Load I (Btuh) Area ft= I or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6> 11 D -- -_._.. C .... _ -iW-- - - IA --flocs 1A-rlov 1A-rlov _11D0 - -- 13A-4ocs 1A-rlov 1A-rl ov- - --- - - 13A4ocs 10A-v 10A-v 1A-rlov 1A-r.1ov--------0.900.-s---_--25.20----19.79_____-�_0--_---.-0_ 13A-4ocs ,A-rlov 1A-rlov 16X19-Omd _._ _ _ . 0.900 0.900 0.900 - -0.390 0.143 0.900 ---0.900 0.143 0.820 0.820 0.900 0.143 0.900 0.900 __. __._ 0.408 n n n . n a a - e s s s s w w w - .- - - 4.20 25.20 25.20 ---10.92 4.00 25.20 _25.20 4.00 22.96 22.96 25.20 4.00 25.20 25.20 . _ ...1.59 -- 9.19 19.79 19.79 ._.,10.34 2.19 42.33 ___42.33 2.19 15.21 15.21 19.79 2.19 42.33 42.33 _1.37 --- 0 0 0 _. -,-,---0 0 0 , - ----0 0 0 0 0 56 8 0 __ _ _-_- 54 -- 0 0 0 ---0 0 0 - -- 0 0 0 - -0 0 0 -- - - -0 0 0 0 0 - 0.--------_0--.----0 194 202 0 _ -_- _ 86 -- 166 - 0 0 0 -- - -----0-- 0 0 - - - 0 0 0 0 106 339 0 . 74 --- ----0 -- 0 0 0 - --0 0 0 -- -- - 0 0 0 0 0 38 0 0 -_ . 36 .------36 --- - - 0 0 0 ------0 0 0 ---- - 0 0 0 0 0 ..--_--_--0_-_- 38 0 0 __. _._ 36 -- 4 - 0 0 0 - 0 0 0 --- 0 0 0 0 0 -0 151 0 0 . _ -. _57 - - 111 - - 0 0 0 -- 0- 0 0 --- - - - 0 0 0 0 0 --__-_0 82 0 0 ... _ -. 49 _.. - -- 0 ---- - -0 0 0 0 0 48 0 0 _ .__ _ 54 --- --6 61 c) AED excursion 1 118 -5 Envelope loss/gain 647 636 1 1 318 127 12 a) Infiltration b) Room ventilation 102 0 27 0 68 0 18 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 749 664 386 145 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 19% 16% 0 0 15 764 146 0 0 13 677 109 19% 16% 0 0 10 397 76 0 0 9 154 25 I I Air requiredal room )oad (cfm) I I I 935I 738I I I 418I 179 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t -iid- wrighl�of[' 2022-Feb-1818:30:52 - RightSuite@Universal 202222.0.01RSU08101 Page10 ...soft HVAQHall Residence - 12793 W Angle Rd.rup Calc = MJ8 Front Door faces: N r - wrightsoft, Wig ht-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772.466-6799 Email: quickcalcs@aol.com 1 Room name Bedroom 3 Hall 2 2 Exposed wall 38.0 ft 0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 13.0 x 13.0 ft 1.0 x 78.0 ft 5 Room area 169.0 ft' 78.0 ft' Ty Construction U-value Or HTM I Area(ft) Load Area ft: Load number (Btuh/ft;* (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool V� -- 1A-r1 ocs - -0. 3' 0.943' - n - _.. 4.20 __ . 2.19 - 118 - - - 104 ------ 454 --- 228 -- 0 - - - 0 - -0 0 0 1A-riov 0.900 n 25.20 19.79 18 0 454 356 0 0 0 0 1A-riov, 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0' (I; -,CGS D 11D0 . - _ . _ _ _ -. - 0.390 n _ _..._ 10.92 ..-_ .10.34 _ __.• .... -. 0 .. _ .._. 0 ,_. .0 - _0 - -0-- 0 _ 0- 11 13A-4ocs 0.143 a 4.00 2.19 113 113 452 247 0 0 0 0 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 1A-rtov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 10A-v 0.820 s 22.96 15.21 0 0 0 0 0 0 0 0 10A-v 0.820 s 22.96 15.21 0 0 0 0 0 0 0 0 1A-r1ov 0.900 s 25.20 19.79 0 0 0 0 0 0 0 0 1A-r1ov._ . --. -- _- ----.-_ 0.900 _ _s._ _._.25.20 . _.19.79 _ __..__.0 _._.._ . _ .. 0 ._-.-.----0 _-_- --__.0 __0 -_ -- 0 -- 0 13A-4ocs 0.143 w 4.00 2.19 122 122 489 267 0 0 0 0 1 A-rl ov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 1A-r1ov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 0.408 _ - _ ._ _ 1.59 .. ___ 1.37 _. 169 .. _ _.169 _ 268 ._ _ 231 _ _. _ -- 78 - _ ._ _ 78 _ _ 124 ._ . - - 107 F 22A-tDl - -- --0.989 - --27.69 - -0.00 --. 169 _----- 38 - -1052 --- ----0 - - --78 - - - -0 ---.0 61 c) AED excursion 1 -541 1 1 13 Envelope losstgain 3132 1275 1 1 124 103 12 a) Infiltration 644 173 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliancestother 0 0 Subtotal (lines 6 to 13) 3776 1678 124 103 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 9 -124 -103 14 Subtotal 3787 1687 0 0 15 Duct loads 19% 16% 724 271 19% 16% 0 0 al load 4173I 1995I required l Air eQUi d (cfm) I I I I I 0 I 0I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -P}+- 2022-Feb-1818:30:52 -- RightSuite®Universal 202222.0.01 RSU08101 Page11 soft HVAC\Hall Residence - 12793 W Angle Rd.rup Calc = M.18 Front Door faces: N wrightsoft Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Bath 2 2 Exposed wall 26.0 ft 3 Room height 9.4 ft heat/000l 4 Room dimensions 1.0 x 79.0 ft 5 Room area 79.0 ft' Ty Construction U-value Or HTM Area (ft') Load I Area I Load number (Btuh/ft'• (Btuhlft-) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross I N/P/S He Cool Gross N/P/S Heat Cool 6 - .- _. - - - - - - 1A-r1 ocs - -- 0.900 --- n - - - 4.20 -- --- - - - - - 0 - - - 0 -- - - 0 ----- - 0 - --- - -- ... - - - - 1A-rlov 0.900 n 25.20 9.19 19.79 0 0 0 0 1A-r1ov 0.900 n 26.20 19.79 0 0 0 0 D 11D0----.-_----. - - _ ._--_ 0.390 _--n- ----10.92 ._ .__10.34 __-.. __0 0- --_ _ _- -0 _ ..0 _ 11 V 13A-4ocs 0.143 a 4.00 2.19 75 75 301 165 1A-r1ov 0.900 a 25.20 42.33 0 0 0 0 lA-rlov.__ - -._ .-- ----0.900 --e- - - 25.20 -_42.33 ---- -0 --- - 0 _.. 13A-4ocs 0.143 s 4.00 2.19 94 --0 71 - -- 286 --0 156 --- -- ---- - 10A-v 0.820 s 22.96 15.21 23 23 520 345 1OA-v 0.820 s 22.96 15.21 0 0 0 0 1A-r1ov 0.900 s 25.20 19.79 0 0 0 0 IA-r1ov-. -_- -.--•- -- __0.900 ._s _ .25.20 _---19.79_--- -._0._.. __ _ 0 13A-4ocs 0.143 w 4.00 2.19 75 75 301 165 1A-rlov 0.900 W 25.20 42.33 0 0 0 0 1A-rloy 0.900 w 25.20 42.33 0 0 0 0 C---.. _ 16X19-0md.---------- - -. - 0.408 --- -_ -1.59 __. 1.37 _ _. -_-79 -.-----79 - ----125 _ _ 108_--- -- - -- - ------ - - F- -- 22A-tol---------..- ----- --- 0.989 ---- M.- - 27.69 .----0.00 -- -79 - - - _26 - - 720 -- - - 0 --- - -- -- - -- - 61 c) AED excursion 1 -13 Envelope loss/gain 1 2253 925 12 a) Infiltration 441 118 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 2694 1043 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2694 1043 15 Duct loads 19% 16% 515 168 roomI oad 3123I 1259I Air requi dl (c m) I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -t`li- wrlgh ai-t7 2022-Feb-1818:30:52 / +A •° RightSuite®Universal 202222.0.01RSU08101 Page12 soft HVAC1Hall Residence - 12793 W Angle Rd.rup Calc = MJ8 Front Door faces: N