Loading...
HomeMy WebLinkAboutBuilding PlansCHASON RESIDENCE AREA SQUARE FEET LIVING SPACE - IST FLOOR Sfol LIVING SPACE - 2ND FLOOR 810 ----------------------------------------------------- TOTAL LIVING SPACE 161-7 COVERED BALCONY 153 GARAGE 96 TOTAL SQUARE FEET 11526 LEFT ELEVATION SCALE: 1/4" = 1'-0" RIGHT ELEVATION SCALE: 1/4 = 1-0 _ TOP OF GABLE WALL +/- 2" ABV ROOFLINE OF ROOF _TOP OF SEAM Top of IST FL 12 __� I' 12" MA TOTAL OVERHANG: ,ubf loor .00R CLG =.E. I Ili SPIRAL I STAIRCASE I I' x I . >x L I L*1 I m �r REAR ELEVATION SCALE: 1/4" = 1'-0" 91-0" r FLOORFINISW SURVEYOR GRADEFINISW TO A50VE TWE 50TTOOF•• Cal GABLE WALL +/- 4" ABV ROOFLINE CEMENTATIOUS FINISH I FRONT ELEVATION SCALE 1/4'�= I -O RECESS LANDING 1 1/2' BELOW F.F. t SLOPE 9'-O" u� o GREAT ROOM _ STEEL COLS m 8' GLCs = (SEE DETAIL ON SHEET DI) v W/ MIN 4" x 16" LVL TO MATCH FLOOR SYSTEM 11SSES DEPTH Q 12'_S" Fu-' uRE WET E 6O6a ESF BEDROOM 03 ?,'CLG BATHROOM 286B PKT LAUNDRY ROOM B' CLG �— GARAGE 8' CLG Q J L bOro& m m Q - BEDROOM *2 01 e' cLG 11'-2" BEDROOM "1 4 —8 C1G Q RECESSS LANDING 11/2" REL.Ou1-�. ;1 $LOPE IST FLOOR PLAN SCALE: 114" • 1'-0" --= PERMIT 220 '-0413 1 SEE CLOUDED Y[SIONS Fi--P 'COMMENT-°, 3-24-22 2 e • (� 00 cn W M tT aw.'mt wQ i�ob�ot-O C'7 ®0rA �a� W (nOOr'nx 1 kn F, Q, a r �f ® Copyright 2021 ROBERSON DESIGN GROUP All rights reserved. REVISION DATE 3-24-22 JOB " 2111 DATE : 9/11/21 DRAWN BY SR SHEETi DOUBLE 2 x PLATE 19" x 6" WEDGE ANCHORS • 32" O.C. MAX. (MIN. 4" EMBD.) 4 (I) 6" FROM EA. END EQUAL OR BETTER ANCHORS MAY BE USED FRAME WALL 2 x SPF STUDS (SEE ERG. WALLS DETAIL) 2 x PT STUD - 6 MASONRY 2 x PT SILL PLATE — 3/4 SUB -FLOOR FNOSING TRUSS SYS 2' X 4-LEDGER (3) 2" X 12" STRINGERS — STAIR DETAILS 3' 2" W 11 RISERS ®1.6" 10" TREADS 10' 8.15" RISE TIE BEAM OR BOND BEAM _Vb� n e a Q A e a BEARING FRAME WALL TO MASONRY ATTACHMENT DETAIL N.T.S. ul HANDRAIL - SHALL HAVE MIN 4 MAX HEIGHTS FROM TOP OF TREAD is NOSING OF 36" 4 38" ap Z `I HANDRAILS SHALL HAVE A EITHER A CROSS E 4 SECTION DIA. BETWEEN 1-1/4" TO 2" OR SHALL Al PROVIDE EQUIVALENT GRASPABILITY. l3 CLEAR SPACE BETWEEN HANDRAIL 4 WALL SHALL BE A MIN. OF 1-1/2" INCHES. (REF. COMPLY TO FBC 2011 6TH ED SECTION R311.1) THRUST BLOCK SECURED TO SLAB STAIR / HANDRAIL DETAIL N.T.S. TIE BEAM OR BOND BEAM 2 x PLATE - 3/8" TAPCONS a (MIN, 1 3/4" EMBD.) 4 (1) 6" FROM EA. END 4 (1) 0 MIDDLE OF STUD EQUAL OR BETTER ANCHORS MAY BE USED FRAME WALL 2 x SPF STUDS 2 x PT STUD a MASONRY 2 x PT SILL PLATE— r f a DOOR E WINDOW BUCK DETAILS N.T.S. (1) 8 x 8 FILLED CELL w (U 05 4 ROD CONTINUOUS EACH CELL FROM FTG. TO BEAM, FILL w CONCRETE (2) 8 x 8 FILLED CELLS w (1) 05 4' ROD CONTINUOUS EACH CELL FROM FTG. TO BEAM, FiLL w CONCRETE, OR 8" x 16" COL, ELK, w (2) 45 4 ROD CONTINUOUS EACH CELL FROM FTG. TO BEAM FiLL w CONCRETE EXTERIOR WINDOW ® GLAI&S ® DOOR ® GARAGE DOOR DOOR I x 4 BORAT I x 4 50RAT 2 x 6 BORAT TREATED PT BUCK 2 x 6 PT BUCK TREATED PT BUCK TREATED PT BUCK TO REQ. WIDTH •2 SYP BUCK WINDOW SLIDING GLASS DOOR EXTERIOR DOOR GARAGE DOOR DOOR 4 WINDOW BUCK ATTACHMENTS AS FOLLOWS: WINDOWS: I X 4 PT BUCKS ATTACHED TO CBS w/ 2" EMBEDMENT &d CASE HARDENED COIL NAILS 6" O.C. 4 3" FROM ENDS SLIDING GLASS DOORS: 1 X 4 BUCKS ATTACHED TO CBS w/ 2" EMBEDMENT 6d CASE HARDENED COIL NAILS 6" O.C. AND 3" FROM ENDS GARAGE DOOR: 2 X 6 PT ATTACHED TO CBS w/ 15" x 6" EMBEDMENT WEDGE ANCHORS a 24" OG.. WINDOWS 4 SLIDING DOORS INSTALLED PER MANUFACTURES SPECIFICATIONS. ATTACH THRU WINDOW FRAME TO CBS w/ 3/16" BY 214" TAPCONS w/ 114" MIN. EMBEDMENT INSTALLED PER MANUF. SPECS. UNLESS OTHERWISE NOTED + PRE -HUNG METAL EXTERIOR DOORS: ATTACH 2 X 6 PT BUCK TO MASONRY w/ 3/16" BY 314" TAPGONS ® 12" O.C. 4 6" FROM EACH END. ATTACH DOOR TO BUCK w/ 010 2 1/2" WOOD SCREWS a 12" D.G. ZONE 1 4 2 - USE SD RING SHANK NAILS a 6" O.C. 4 ZONE 3 6 4" O.C. TYPICAL NAILING PATTERN FOR ROOF SHEATHING 8" 1/4" STEEL SIZED FOR PLATE I" I" BEAM 0 0 i 61DEVIEW 0 0 1" HOLES DRILLED a/16" FOR 1/2" THRU BOLTS TOP OF STEEL BEARING POST DETAIL 4" X4" X 1/4" ASOO STEEL COL. (2) - 1/2" X 6" WEDGE 4" x 4" x ANCHORS EMBED. INTO 1/4" FLANG 24" CONT, CONIC, MONO FTG.,,,` RECESS FOR POST/FLANG Pa. dn.. �n.. do I'PD Eoa EoD If, 14, ",", d 4 4 " 1 1=, BOTTOM OF STEEL BEARING POST DETAIL STEEL BEARING POST DETAIL N.T,S. 12 SEE ELEVATIONS FOR ROOF PITCH 5/8" DRYWALL OR CLG. BOARD 1/2" P.T. NAILER 1/2" DRYWALL CURTAIN NAILER I X 4 P.T. @ WINDOWS I X 8 P.T. o S.G.D. DEL. 2" x 8" P.T, LEDGER W/ 1/2" ANCHOR BOLTS AT 24" O.G. 6" EMBED. TYP. SUB -FLOORING 3/4" PLYWOOD 1 NAILED TO FLOOR FRAMING w/ 08 RINGSHANK NAILS OR BETTER 6 O.C. ON THE EDGES 4 IN THE FIELD. FLOOR JOIST SYSTEM (SEE TRUSS PLAN FOR SIZE) 1 , \ V+ �+ , 5/8" DRYWALL TYPE OR CLG. BOARD SILL i X 2 P.T FURRING \ 0 16" O.G. MAX R 4.2 FIFOIL INSULATION OR EQUAL 3/4" CELOTEX INSULATION BOARD 1/2" DRYWALL i X4PIT. BASE NAILER BASE SEE SLAB NOTES ON SHEET 5-1 FOR SLAB REQUIREMENTS SEE FOUNDATION PLAN ON SHEET 5-1 FOR FOUNDATION REQUIREMENTS SIMPSON STRONG-TiE CLIPS / STRAPS / TIE -DOWNS / HANGERS - ETC TO BE USED FOR WOOD TO WOOD CONNECTIONS INSTALLED PER MFG REQUIREMENTS (EQUAL OR BETTER CONNECTORS MAY BE USED) FLASHING FOR FENESTRATION IN MASONRY WALLS AS PER FBC R103.8.1 THE FOLLOWING WILL BE APPLIED ... DUPONT TYVEK FLUID APPLIED FLASHING -BRUSH FORMULATION FOR MASONRY WALLS FOLLOW ALL INSTALLATION GUIDELINES FLASHING FOR FENESTRATION IN FRAME WALLS AS PER F5C R612.10 THE FOLLOWING WILL BE APPLIED... DuPONT TYvEK FLASHING TAPE 4 FLEXWRAP FOR FRAME WALLS - FOLLOW ALL INSTALLATION GUIDELINES PRE ENGINEERED WD TRUSSES B 24" O.C. ATT OR BLOWN INSULATION (PER ENERGY CALCS - R-30 VALUE) SIMPSON STRONG TIE AT EACH TRUSS SEE CONNECTOR NOTES ON PG T-I FOR REQUIRED STRAP METAL ROOF (SEE PRODUCT APPROVAL ON COVERSHEET) OVER PEEL 4 STICK UNDERLAYMENT OVER 5/8" G.D.X. PLYWOOD (SEE NAILING PATTERN FOR SHEATHING) _ SEE ELEVATIONS FOR WALL HEICsI ( TOP OF BEAM) METAL DRIP EDGE IX2PIT. VENTED STUCCO 2 X 6 FASCIA SOFFIT U.N.O. MAX TOTAL 12 OVERHANG INCLUDING FASCIA 4 DRIP EDGE (SEE ELEVATIONS) GONG. FILLED "BEAM" BLOCK W/ 1-05 BAR CONT. PRECAST "U" LINTEL FILLED w/ GONG. (SEE LINTEL SCHEDULE FOR SIZES) ALUM FRAMED WINDOW W/ SCREEN (SEE FLOOR PLAN FOR SIZE) (U 05 VERT, ROD 0 ALL LOCATIONS SHOWN ON SHEET 5-1 BEAM HEIGHT +/- g' 4" A,F.F. m MIN. (2) ROWS OF "BEAM" BLOCK W/ 1-05 BAR CONT. BTM OF FLOOR SYS +/- 8' A.F.F. n, MIN. (3) "5 4 REBAR PRECAST "U" LINTEL FILLED w/ GONG. (SEE LINTEL SCHEDULE FOR SIZES) WINDOW W/ SCREEN (SEE FLOOR PLAN FOR SiZE) - PRECAST GONG SILL _ 8 X 8 X 16 GONG. BLOCK CEMENTATIOUS COATING OVER CONCRETE BLOCK 1/8" THICK (1) 05 VE:RT, ROD 6 ALL LOCATIONS SHOWN ON SHEET 6-1 05 HOOK MIN 18" EMB. 30 BAR 4, EXTENSION OPTIONAL RECESS 1 1/2" BELOW F.F. FINISH FLOOR ELEV. TOP OF SLAB GRADE MIN 4" BELOW FINISH FLOOR ELEV.) 12" MIN DEPTH BELOW GRADE TYPICAL 2 STORY CONCRETE BLOCK WALL SECTION N.T.S. DOOR OPENING BETWEEN RESIDENCE LIVING AREA 4 GARAGE PER FBC 2020 TTH ED. - CODE R302.5.1 Opening protection. Openings from a private garage directly into a room used for sleeping rurposes shall not be permitted. Other openings between the garages and residence shall be equipped with solid wood doors not less than 1 3/8" (35mm) in thickness, solid or honeycomb -core steel doors not less than 1 3/8" (35mm) thick, or 20-minute fire -rated doors, equipped with a self -closing device. FRAME WALLS BETWEEN RESIDENCE LIVING AREA 4 GARAGE PER FBC 2020 -iTH ED. - CODE R302.6 The garage shall be separated from the residence and its attic area by not less than I,!z -inch (12.1mm) gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooma above bg not less than 5/8" (15.5mm) Type X gypsum board or equivalent. Where the separation To a floor-celllrg assembly, the structure suppo^ting the separation shall also be protected by not less Char 14" (12,1mm) gypsum board or equivalent DUCTWORK TO COMPLY w/ FBG 2020 1TH ED. - CODE R302.5.2 Duct penetration. Ducts In the garage and ducts penetrating the walls or ceilings separating the dwel€Ing from the garage shall be constructed of a minimum No. 26 gage (0.48mm) sheet steel, I inch (25.4mm) minimum rigid nonmetallic Class O or Class 1 duct board, or other approved material and shall have no openings into the garage. CAP KNEEWALL w/ FLASHING FOR WATERPROOFING KNEEWALL TRUSSED ROOFLINE TO FOLLOW ROOFLINE DOUBLE 2 x 6 PLATE PRE ENGINEERED w/ SIMPSON Sp 6 WOOD TRUSSES s 24" O.G. * EACH STUD BATT OR BLOWN INSULATION I X 4 BRIDGING SIMPSON STRONG TIE AT EACH TRUSS • 8' O O.C. SEE CONNECTOR NOTES ON PG T-1 MAX. FOR REQUIRED STRAP i DID" DRYWALL — DOUBLE 2 x 6 PLATE w/ 611 IPSON SP 6 0 EACH STUD TRIPLE 2 x 12 SPF w it" CDX PLYWOOD FLITCH NAILED w/ 16D NAILS 12" O.G. 3 ROWS OR BETTER HEADER a OPENINGS 2NO FLOOR WALL 2 x 6 PT BTM PLATE w/ SIMPSON SP6 • EACH STUD, FRAME WALL STUDS • 16 O.C. MAX. FLOOR JOIST SYSTEM (SEE TRUSS PLAN FOR SIZE) , , ENTER UP SEE ELEVATIONS FOR WALL HEIGHTS ( TOP OF BEAM ) 1/2" x 6" LAG BOLT w/ WASHERS ® EACH FLOOR JOIST FLOOR JOIST SYSTEM SIGNED BY TRUSS CO.. \ \/ / IST FLOOR CLG. TYPICAL 2 x 6 - 2 STORY FRAME WALL SECTION N.T.S. 04' STAR DIAMETER Off w-mooJ Fkro MODEL ALUMINUM DIAMETER (IN.]: W Do�OO v v v Ilk FLOOR TO FLOOR (IN.): 114 COLOR: RAW 1111t�� RISER HEIGHT (IN.): 9.5 30 DDEGREE. OOM (IN.�81.5 3D RENDERIN_�+ PERMIT 2202-O4'ai SEE CLOUDED EVI,F5,IONS FER COMMENTS 3--.4-22 -- REVISED INSULATION NOTE i A // • • 0 ■ �r ® Copyright 2021 ROBERSON DESIGN GROUP All rights reserved. REVISION DATE 3-24-22 JOB 0 2111 DATE : 8/11/21 DRAWN BY SR 6HEET ELECTRICAL FLAN - 2ND FLOOD SCALE: 114" = V-0" 200 AMP MAIN BREAKER 30 CIRCUIT (3) WERE -1 PHASE ELETRICAL PANEL SCEWMM COND. BREAKER SIZE CIRCUIT NAME WATTS 1P 20A # 14 GENERAL LIGHTING 1926 SF a 3VA 2778 2P 25A # 12 SMALL APPLIANCES 2 z ISM 1P 20A # 12 LAUNDRY 1 z 1500 1500 2P 50A # 6 RANGE 12000 2P 30A # 10 DRYER 5000 2P 30A # 10 WATER HEATER 4500 1P 20A # 12 REFRIGERATOR 1200 1P 20A # 12 DISPOSAL 864 IP 20A # 12 DISHWASHER 1176 1P 20A # 12 WELL PUMP 1940 1P 20A # 12 POOL PUMP 1840 1P 20A # 12 GARAGE DOOR OPENER 600 1P 20A AI 12 CEILING FANS 9 a 360 3240 1P 20A # 12 BATH EXHAUST FANS 3 a 130 540 2P 30A AI 10 AC CONDENSER (6500) --- 2P 50A Ak 6 AC AIR HANDLER (10000) --- 2P 30A #i 10 AC CONDENSER (6500) --- 2P 50A # 6 AC AIR HANDLER (10000) --- TOTAL 43%2 **FIRST 10KW @ 100% 10000 REMAINDER OF "OTHER LOAD" @ 40 % 13625 (2) AC / HEAT 10KW @ 65 % 13000 DEMAND 36625 36625 VA / 240 = 152.60 AMPS 1DI ' 11: 11 DI �,&Twljffl ; , 2" PIPE (2) 410 AL (1) 210 AL 2" CONDUIT ELECTRIC 1 Il) w 01, 4- ALL WORK TO COMPLY WITH NEC AND FLORIDA BUILDING COD ' 1 1 tZ 1' - I !WIN ".. 1 ELECTICCAL FLAN - 1ST FLOOR SCALE: 1/4" - 1i-0l" ELECTRICAL LEGEND [�JAc 018G. AC DISCONNECT TV OUTLET fCAR50N 5 MONOXIDE SMOKE ALARM COMBO $DM DIMMER SWITCH DOOR CHIME ® EXHAUST FAN EXHAUST FAN LIGHT F FAN LIGHT F o FAN OUTLET CQo FLOOD SPOTLIGHT FLOOR � OUTLET FLOOR OUTLET FLUORESCENT FIXTURE FLUORESCENT LIGHT GARAGE DOOR OPENER GFI(b GFI OUTLET �vvr-Gat GFI WATER PROOF rarl. 42" A.F.F. Gr-i OUTLET Q 42" A.F.F, ® WI -HAT �} LIGHT ([] METER OUTLET OUTLET 220v OUTLET INS SOFFIT OUTLET IN SOFFIT PP 200 AMP PANEL 200 AMP PH PHONE JACK PLANT SHELF OUTLET PLANT SHELF OUTLET PULL CORD LIGHT p PUSH BUTTON RECESSED LIGHT to SCONCE LIGHT ® SMOKE DETECTOR 6 SPLIT RECEPTACLE $ SWITCH $3 SWITCH 3 WAY SWITCH 4 WAY SWITCHED LIGHT ® VAPOR PROOF LIGHT GENERAL ELECTRICAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2017 NATIONAL ELECTRIC CODE & SHALL CONFORM WITH THE FLORIDA BUILDING CODE & ALL LOCAL CODES. 2. FAMILY ROOMS, BEDROOMS, LIVING ROOMS, SUNROOMS, DENS, HALLWAYS, CLOSETS, OR SIMILAR ROOMS OR AREAS TO HAVE ARC FAULT PROTECTION PER 2017 NEC SECTION 210.12 (B) 3 . ALL 15 & 20 AMP RECEPTACLES IN KITCHENS, FAMILY ROOMS, BEDROOMS, LIVING ROOMS, SUNROOMS, HALLWAYS, CLOSETS, OR SIMILAR ROOMS OR AREAS TO BE OF THE TAMPER RESISTANT TYPE PROTECTION PER 2017 NEC SECTION 406.11 4. GFI OUTLETS ARE TO BE INSTALLED IN THE KITCHEN, BATHROOM, GARAGE, & OUTSIDE LOCATIONS AS NOTED (GFI) ON PLANS. 5. FINAL PLACEMENT OF ALL ELECTRICAL COMPONENTS TO BE DETERMINED BY THE ELECTRICIAN OF RECORD IN ACCORDANCE WITH THE 2017 NATIONAL ELECTRIC CODE & SHALL CONFORM WITH THE FLORIDA BUILDING CODE & ALL LOCAL CODES. 6. ENGINEER OF RECORD NOT RESPONSIBLE FOR ELECTRICAL PLANS PERMIT 0 ,, CLOUDED REVISIONS I -22 A °O O wM ON Oa3 CjpW,,'�mN Q� z00 W Q , zo u oho 0v3Dcq �Fa C) x g ." O 1" a, C/1 • I 0 Copyright 2021 ROBERSON DESIGN GROUP All rights reserved. REVISION DATE 2-3-22 JOS " 2111 DATE : 8/11/21 DRAWN BY SR SWEET L E=sl GENERAL NOTES I. CONSTRUCTION SHALL FOLLOW "FBC 2020 lTH EDITION" AS ADOPTED BY THE AREA IN WHICH THE BUILDING IS TO BE CONSTRUCTED WITH ALL APPLICABLE AMENDMENTS. 2. THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ETC. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOBSITE, PLANS, SPECIFICATIONS, ETC. 3. ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4. STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES., STRUCTURAL NOTES I. DESIGN LOADS IN ACCORDANCE WITH FBC 2. SOIL BEARING CAPACITY: 2500 PSF 3. ALL STRUCTURAL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. 4. SLAB/FOOTINGS TO BE CONCRETE WITH A MiNIMUM 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLANS FOR SIZE AND STEEL REQUIREMENTS. 5. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" BEAMS: 1 412" SUSPENDED SLABS: I" 6. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR 0. GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS. -T. ALL LUMBER IN CONTACT. WITH CONCRETE - OR MASONRY WILL BE PRESSURE TREATED. S. ALL STANDARD LUMBER SHALL BE SPF 03, HEM FUR 03 OF STUD GRADE WITH A MINIMUM FB = 1200 PSI OR BETTER S. SPLITTING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALLATION OF HARDWARE IS NOT PERMITTED. 10. UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURERS INSTRUCTIONS AND STANDARD PRACTICE, 11, BEARING POINTS OF TRUSSES SHALL HAVE EQUIVALENT VERTICAL STUDS IN A NUMBER EQUAL TO THE NUMBER OF PLIES OF THE BEARING MEMBER WHEN THE BEARING MEMBER IS 2 OR MORE PLIES UNLESS NOTED. 12. ROOF SHEATHING TO BE NAILED WITH 8D RING SHANK GALV. NAILS OR EQUAL 4" O.C. EDGES AND ro" O.C. ON FIELD 13. UNLESS OTHERWISE NOTED FOR EXTERIOR -WALLS, EXTERIOR PLYWOOD SHEATHING AND INTERIOR DRYWALL IS TO BE NAILED WITH SD RING SHANK OR BETTER NAILS 6" O.C. EDGES AND 8" O.C. ON FIELD, OR SCREWED WITH DRYWALL SCREWS Ills INCHES LONG AND 0.131 INCHES DIAMETER 14. FRAME TO MASONRY SEGMENT CONNECTIONS: PT 2 X 4 MiNiMUM TO MASONRY WiTH Ifs" DIAMETER 6" EMBEDMENT: WEDGE BOLTS (1) AT TOP AND BOTTOM AND 36" O.C. THEREAFTER. 15. EXTERIOR CEILINGS - HIGH RIB LATHE 4 CEMENTATIOUS FINISH, 16. ADDITIONAL TRUSS STRAPS MAY BE ATTACHED USING MSTA 18 w/ l IOd NAILS 4 (3) 3/16" x 24" TAPCONS EMBED. 2" MIN. IN BEAM Il. TRUSS CO. IS RESPONSIBLE FOR ALL TEMP. 4 PERMANENT LATERAL BRACING, GABLE ENDS TO BE X-BRACED. 18, THE FLAME SPREAD AND SMOKE INDEX OF THE WALL AND CEILING FINISHES IN ACCORDANCE WITH 302.S.1 AND 302.S.2 OF THE FBC: THE FLAME SPREAD = 200 AND THE SMOKE INDEX = 450 IS, THE INSULATION FLAME SPREAD AND SMOKE INDEX IN ACCORDANCE WITH 302.10.1 AND 302.10.2 OF THE FBC: THE FLAME SPREAD - 25 AND THE SMOKE INDEX - 450 20. THE WEATHERING, TERMITE AREA AND DECAY AREA IN ACCORDANCE WITH TABLE 301.21U OF THE FBC: THE WEATHERING - NEGLIGIBLE 4 THE TERMITE AREA = VERY HEAVY 21, THE BACKER BOARD BEING USED BEHIND TILE IN SHOWER 4 TUB AREAS IS IN ACCORDANCE WITH 102.4 OF THE FBC: FOUNDATION NOTES 1, FOUNDATIONS ARE DESIGNED ON THE ASSUMPTION OF A MIN, SOIL BEARING OF 2500 POUNDS PER SQUARE FOOT 2. IT SHALL BE THE OWNERS RESPONSIBILITY TO ASSURE THAT THE ACTUAL SOIL BEARING VALUE EQUALS OR EXCEEDS THIS MIN. AND IF IT IS LESS, TO MAKE SURE PROVISIONS ARE TAKEN AS THE ACTUAL CONDITIONS MAY REQUIRE. 3, ALL WORK SHALL BE DONE IN ACCORDANCE WITH ALL PERTINENT, LOCAL, STATE, AND FEDERAL BUILDING REGULATIONS, 4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO COMMENCING WORK. 5. COLUMNS, BEAMS, AND WALLS OR ANY OTHER STRUCTURAL MEMBER PENETRATING SLABS ON FILL SHALL BE ISOLATED BY PRE -MOULDED JOINT FILLER (12" THICK) COMPLYING WITH ASTM B 1152 , TYPE 1. MONO -SLAB NOTES 1) 4" SLAB WITH FIBER -MESH OVER CLEAN COMPACTED, NON ORGANIC FILL TO SS% DENSITY 2) SOIL BELOW SLAB TO BE TERMITE TREATED PRIOR TO SLAB POUR 3) 5" SLUMP, 3000 PSI CONCRETE WITH FIBER -MESH OVER 6 MIL VAPOR BARRIER 4) ALL FOOTINGS DESIGNS BASED ON 2500 PSF SOIL BEARING CAPACITY, CONTRACTOR TO VERIFY FILLET? CELLS lu/ VERTICAL BARS I. ALL DOWELS AND VERTCAL BARS ARE 05 2. ATTACH DOWELS TO FOOTING STEEL 3, VERTICAL BARS TO EXTEND TO TO TOP STEEL AND HAVE HOOKS MIN EQUAL TO DOWEL HOOK. Y51, 4. FILL CELLS AT VERTICAL DOWELS. 5. GROUT TO BE 3000 PSI ASND 10" REBAR TO BE GRADE 60, DOWEL ROD REPAIR NOTES IN THE EVENT STEEL HAS BEEN INADVERTENTLY OMITTED FROM DOWN POUR LOCATIONS, DRILL 6" INTO CONCRETE (NO CLOSER THAN 3-3/4" FROM EDGES AND 5" FROM ENDS OF CAP WALLS). REMOVE DUST PER MFG'S INSTRUCTIONS AND USE TWO PART EPDXY TO ANCHOR 05 REBAR IN PLACE. USE EITHER HILT[ C-100 OR SIMPSON EPDXY -TIE. 05 REBAR AT TOP MIN. (U REQ'D 1-1/2" CLEAR J * n Q O y GROUT ° 05 REBAR AT BOTTOM us ° OF LINTEL CAVITY ' I BOTTOM REINFORCING k# PROVIDED IN LINTEL l-5/8"ACTUAL (VARIES) 8 NOMINAL WIDTH F = FILLED WITH GROUT / U = UNFILLED QUANTITY OF 05 REBAR AT BOTTOM OF LINTEL CAVITY 8F16-1B/IT 1 NOMINAL [QUANTITY WIDTH OF 05 NOMINAL REBAR AT TOP HEIGHT LINTEL TYPE DESIGNATION CAST CRETE LINTEL SCHEDULE ALLOWED APPLIED ALLOWED APPLIED MARK LENGTH LOAD LOAD LOAD LOAD SPECIFICATION NO. GRAY, GRAv. UPLIFT UPLIFT Qj 4'-6" 6113 2000 2124 1000 SFi6-15/iT 2 4'-611 5206 2000 2255 1000 SRF14-15/1T 5'-10" 4360 2000 2093 1000 SF16-15/1T Q4 l'-0 2661 2000 1634 1000 SF16-1131iT 5 l'-6" 245S 2000 1462 1000 8RF14-I5/iT Q10'-6" 1533 1000 S14 SOO 81=16-15/ T MIN. BTM DEPTH SHOWN, DEPTHS MAY INCREASE W/O COMMENT SANITARY IOLUME31NC-4 TO 2ND 3 RISER FLOOR VTR h r, DIAGRAM 2„ 211 FUTURE WET BAR KITCHEN VENT UNDER CAB. VENT q11 UNDER GAB 211 TUB I!9" LAY 4 3 11 w.c. 411 J4-II ,1, G.O. TO SEPTIC OR SEWER EXACT PLACEMENT OF PLUMBING BY PLUMBING CONTRACTOR NOTICE It is important that the client and contractor examine the drawings and documentation in detail. It shall be the final responsibility of the contractor to review and double check the plans for accuracy and compliance with regulatory agencies, It is customary and ordinary not to include details well within the knowledge of a licensed Contractor. IF necessary, further clarificatlon of these plans should be achieved before signing the construction contract and obtaining a building permit, otherwise the Contractor assumes responsibility for the construction in question, Methods of construction shall be determined by the Contractor. SEE SLAB / FOUNDATION NOTES 4" GRADE 24 O O O (3) "5 L MIN. REBAR OF 12" COVER I ,e24'al. TYPICAL MONOLITHIC F-i ( MONO,) FOOTING N.T.S. m O M A L 0 M 0 M Cr V4 g3 BALCONY RECE88 LANDING 1 1/2" BELOW F.F. 4 SLOPE 6 1 ® �° TYP. FILLED CELL Q I ® _ U3 / o w (i) 05 4. ROD CONTINUOUS o ® �y FROM FTC. TO BEAM 9 O 0 — -4"xl6"LVL 3...0.. ISLAND TYP. FILLED CELL w (1) •5 a ROD CONTINUOUS FROM FTG. TO BEAM Cr m EXACT PLACEMENT OF PLUMBING ® BY PLUMBING CONTRACTOR PER THE FBC 2020 -TTH ED. C/L OF WALL 2ND FLOOR FILLED CELL 4 LINTEL PLAN SCALE: 1/4" = P-011 lr/ O ' FINISH FLOOR ELEVATION PER SURVEYOR IS is 5,51' FiNISH GRADE +/- 4.51 TO eE A MIN. 12" ASOVE THE BOTTOM OF FOOTING Q ' STEEL COLS 4 " (SEE DETAIL ON SHEET DI) p w/ MiN 4" x 16" LVL ® •----------- --- - -- - - - - - -- - I I , x 2 ® PLUMB FOR a FUTURE WET BAR I , n , , 1 �- w, ,T i o I C/L OF WALL I I ; I I � r 1 I , � 4 I ' , , I ' , 0 ® I I , , 4 Cq I ! , h m 4 I I I 4 I ' CA I I ® I GARAGE I F—� Q I ' RECESS LANDING 1 1/211 BELOW F.F. =1 � ® b a 6LoPE SLOPE 1 I 4 r-' 10 IST FLOOR FOUNDATION / FILLED CELL / LINTEL PLAN SCALE: 1/4" - I'-O" PERMIT * 2202-049i SEE CLOUDED REVISIONS PER COMMENTS 3-24-22 REVISED FOOTING DEPTH TO 24" t OW en W i O� M W z lr \.J Z 0 °�3'�rp 2) wOoFa rn V Zt,' J-1-1 m V! LU WI— t— Z n LU ^ z Z V VVV I C Copyright2021 ROBERSON DESIGN GROUP All rights reserved. REVISION DATE 4-6-22 JOB " 2111 DATE : 5/11/21 DRAWN BY SR SWEET � —