HomeMy WebLinkAboutDuct Leakage Test ReportZ/o - icjo Job Information Builder: DR HORTON Address: 9516 POTOM City: FORT PIERCE Duct Leakage Test Results System 1 System 2 System 3 Sum of any additional systems Total of all systems APR 072022 St. 4(jcie Co Permigin, my Duct Leakage Test Report Prescriptive or Performance Method Permit # --/D)0 / State: FL Presciptive Method Q Performance Method Pau qk�ib,-t Lot: 119 crm25 WFrescriptive Method cfm25 (total) To qualify as "substantially leak free" Qn must be less than or equal to 0.04 cfm25 if air handler unit is installed, If air handler unit is not installed, Qn Total must be less than or equal to 0.03. This testing method meets the cfm25 requirements in accordance with Section R403.2.2 55 1916 = 0.02 Qn Total of all systems Total Conditioned square Footage LXPASS D-, FAIL Testing Company Q Performance Method cfm25 (Out or Total) To qualify as "substantially leak free" Qn must not be greater•tilan the proposed duct leakage Qn specified on Form R405-2014 Leakage Type selected Qn specified on Form on Form R405-2014 R405 2014 (Energy Colc) .(Energy Calc) Company Name: SUN SEAL LLC Phone: 321-412-0035 I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the'selected compliance path as stated above, either the Prescriptive Method or Performance Method. Date of Test: 03/21 /2022 Signature of Tester: Printed Name of Tester:. DAN EL MURPHY h License/Certification # 5066440 Issuing Authority gpl y— APR 0 7 2022 St. Lucie County Permitting Envelope Leakage Pest Report (Blower Door Test) R405.4.2.1 Compliance (Permit# y�Ory[ ICi0 Job Information Builder: DR 40 q Community: CREEKSIDE Address: 9516 POTOMAC DRIVE City: FORT PIERCE Unit: State: FL Zip; Air Leakage Test Results Passing results must be 7ACH(SO) orless 1273 x 60 ., 16477.6 = 4.6 CFM(50) Building Volume ACH(50) 2 PASS r I FAIL Lot: Method for calculating building volume• Q Retrieved from architectural plans Bode software calculated Q Field measured and calculated When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Certification of Test Results a ecw,c.4.z.z Testing. The building or dwelling unit shall be tested and verified. as having an air leakage rate of not exceeding 7 a(r changes. per hour in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by wither individuals as defined in'Sectlon 553.993(5) or (7), F.S. or Individuals licensed as set forth in Section 489.105(3)(f), (g}, or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Testing Company Company Name: SUN SEAL LLC Phone: 321-412 I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive Method or Performance Method. Date of Test: 03/21/2022 Signature of Tester; Printed Name of Tester: DANIEL MURPHY License/Certification # 5066440 Issuing Authority BPI