Job Information
Builder: DR HORTON
Address: 9516 POTOM
City: FORT PIERCE
Duct Leakage Test Results
System 1
System 2
System 3
Sum of any additional
systems
Total of all systems
APR 072022
St. 4(jcie Co
Permigin, my
Duct Leakage Test Report
Prescriptive or Performance Method
Permit #
--/D)0
/ State: FL
Presciptive Method Q Performance Method
Pau qk�ib,-t
Lot: 119
crm25 WFrescriptive Method cfm25 (total)
To qualify as "substantially leak free" Qn must be less than or equal to 0.04
cfm25 if air handler unit is installed, If air handler unit is not installed, Qn Total
must be less than or equal to 0.03. This testing method meets the
cfm25 requirements in accordance with Section R403.2.2
55 1916 = 0.02 Qn
Total of all systems Total Conditioned
square Footage
LXPASS D-, FAIL
Testing Company
Q Performance Method cfm25 (Out or Total)
To qualify as "substantially leak free" Qn must not be greater•tilan the
proposed duct leakage Qn specified on Form R405-2014
Leakage Type selected Qn specified on Form
on Form R405-2014 R405 2014 (Energy Colc)
.(Energy Calc)
Company Name: SUN SEAL LLC Phone: 321-412-0035
I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the'selected
compliance path as stated above, either the Prescriptive Method or Performance Method.
Date of Test: 03/21 /2022
Signature of Tester:
Printed Name of Tester:. DAN EL MURPHY
h
License/Certification # 5066440 Issuing Authority gpl
y—
APR 0 7 2022
St. Lucie County
Permitting
Envelope Leakage Pest Report
(Blower Door Test)
R405.4.2.1 Compliance
(Permit# y�Ory[ ICi0
Job Information
Builder: DR 40 q Community: CREEKSIDE
Address: 9516 POTOMAC DRIVE
City: FORT PIERCE Unit:
State: FL Zip;
Air Leakage Test Results Passing results must be 7ACH(SO) orless
1273 x 60 ., 16477.6 = 4.6
CFM(50) Building Volume ACH(50)
2 PASS r I FAIL
Lot:
Method for calculating building volume•
Q Retrieved from architectural plans
Bode software calculated
Q Field measured and calculated
When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department.
Certification of Test Results
a
ecw,c.4.z.z Testing. The building or dwelling unit shall be tested and verified. as having an air leakage rate of not exceeding 7 a(r changes.
per hour in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a
pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by wither individuals as defined in'Sectlon 553.993(5) or (7), F.S. or
Individuals licensed as set forth in Section 489.105(3)(f), (g}, or (i) or an approved third party. A written report of the results of the test
shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of
all penetrations of the building thermal envelope.
Testing Company
Company Name: SUN SEAL LLC Phone:
321-412
I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected
compliance path as stated above, either the Prescriptive Method or Performance Method.
Date of Test: 03/21/2022
Signature of Tester;
Printed Name of Tester: DANIEL MURPHY
License/Certification # 5066440 Issuing Authority BPI