HomeMy WebLinkAboutDuct Leakage Test ReportDuct Leakage Test Report
• Prescriptive or Performance Method
Permit # Z/OS — D EW 7
1ob'Information
Builder: DR HORTON
Address: 344$ TRINITY CIRCLE
Community: CREEKSIDE. Lot: 22
Unit:
City: ;FORT PIERCE
State: 'FL Zip: 34945 .
Duct leakage Test R®salts Preselptive'Method Q 'Performance Method
System 1
cfm2s
&frescriptive Method cfm25 (total) d
System 2
To qualify as "substantially leak free" Qn must be less than or• equal to 0.04
cfm25
if airhandier unit is installed., if air handler unit is not installed•; Qn Total
System 3
must be less than or equal to 0,03. This testing, methofteel� the
efm25
requirements in -accordance with Section 11403.21
Sum of any additional
systems
cfm25
Total of all systems
0 Performance Method cfm25 (Out or Total)
OM25
To qualify as "substantially leak free" Qn must not begreate'r.:than the
proposed duct leakage Qn specified on Form R405-2014 ;
50 _
1768 = 0.02 Qn
Total of all systems
Tl otaConditioned
k L
Leakage Type selected an s
pecifled on form
Square Footage
on form R405-2014 R405 2014 (Energy Calc)
PASS
FAIL
(Energy COW
1-----
Testing Company
Company Name: SUN SEAL LLC Phone: 321-412-0035
I hereby verify that the above duct leakage testing.results are in accordance with the Florida Building Code requirements witio the selected
compliance path as stated above, either the Prescriptive Methodor Performance Method.
Date of Test: 03/2.1 /2022
Signature of Tester:
Printed Name of Tester: DAN EL MURPHY
License/Certification # 5066440 Issuing Authority BPI
alp ����i�Fo• .
R
Envelope Leakage Test Report spo; ��?�??
(Blower Door Test) e�c9un
R405.4.2.1 Compliance
(Permit O 817
Information
Unit:
Air Leakage Test Results Passing results must be 7ACH(50) or less
1364 x 60 _ 14381.6 = 5.6
CFM(50) Building Volume ACH(50)
PASS EJ FAIL
'Lot:
Method for.caiculating building volume-
Q Retrieved from architectural plans
E<Code softwarecalculated
Q Fieldmeasured and calculated
I When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department.
of Test Results
o -• ••-wu %pm a u anu vcl muu a5 ndv,ng an air ieaKage rate of not exceeding 7. r changes
per hour:in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with_a.blower door at a
pressure•of 0.2 inches w.g..(s0 Pascals). Testing shail be conducted by wither individuals as defined in Section 553.993(5) or (y), R.S. or
individuals licensed as set forth. in Section 489.305(3)(Q,;(g), or (1) or an approved,third party. A.written report of the results df the test
shall be sighed by the party conducting the test and provided to -the code official. Testing shall be performed atany time aft0rcreation of
all penetrations of the buildina thermal envpinnp_
Testing Company
:ompany'N'ame: SUN SEAL LLC Phone: 321-412-0035 r,
hereby verify that the•above duct leakage testing: results are in accordance with the Florida. Building Code requirements wki, the.selected
ompliance path as stated above, either the Prescriptive Method or Performance Method.
ti.
Date of Test: 03/21 /2022
Signature of Tester:
Printed Name of Tester. DANIEL MURPHY
License/Certification # 5066440___issuing Authority Bpi
Y