HomeMy WebLinkAboutEnergy Efficiency Code' ;.9
-
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 60 Block 1 Waterstone 1820 BGL
Builder Name: ADAMS HOMES
Street: 8705 Merano Avenue
Permit Office:
City, State, Zip: Fort Pierce, FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type42120.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1850.00 ftZ
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
c. N/A
R=13.0 270.00 ftZ
R= ftZ
4. Number of Bedrooms 4
d. N/A
R= ftZ
5. Is this a worst case? No
11. Ceiling Types (1900.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1820.00 ftZ
6. Conditioned floor area above grade (ftZ) 1820
b. Knee Wall (Vented)
R=19.0 80.00 ft2
Conditioned floor area below grade (ftZ) 0
c. N/A
R= ftZ
7. Windows(239.3 sqft.) Description Area
12. Ducts
R ftZ
a. U-Factor: Dbl, U=0.33 168.74 ftZ
a. Sup: Attic, Ret: Main, AH: Main
6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ftZ
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.33 20.42 ftZ
SHGC: SHGC=0.31
Area Weighted Average Overhang Depth: 4.067 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.269
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ftZ
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1820.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ftZ
b. Conservation features
b. N/A R= ftZ
None
c. N/A R= ftZ
16. Credits
Pstat
Glass/Floor Area: 0.131 Total Proposed Modified Loads: 61.10
PASS
Total Baseline
Loads: 64.83
I hereby certify that the plans cations covered
this in
Revie of the plans and
OSc-TKB ST"-
calculation are compli c i ergy
specifications covered by this
=p.
Code.
calculation indicates compliance
y'� ��,, '� a =;: ��•�,
with the Florida Energy Code.
ti. tir,/%, •,;: `;,. a ,� O.
PREPARED BY:
Before construction is completed
DATE: 07-1R-217121 Winn Kenmany
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida code.
Cp•
Dom.
OWNER/AG
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
7/16/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 60 Block 1 Waterstone 18
User
1
ADAMS HOMES
661000
Detached
New (From Plans)
Bedrooms: 4
Conditioned Area: 1820
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Lot Information
60-1
Waterstone
8705 Merano Avenue
St. Lucie
Fort Pierce ,
FL , 34951
CLIMATE
/
V Design Location TMY Site
Design Temp
97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name Area
Volume
1
Block1 1820
18200
SPACES
Number
Name Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main 1820 18200 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type Space
Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main
33 ft 0
1820 ft2 ----
0.42 0 0.58
ROOF
/
V/ #
Type Materials
Roof Gable Roof
Area Area Color
Red Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Shed Composition shingles
2035 ft2 456 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic Vented
300 1820 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
1820 ft2 0.11
80 ft2 0.11
Wood
Wood
7/16/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4
i
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity ity Width
Height
Sheathing Framing
Solar Below
0
1 E
Exterior Concrete Block - Int Insul
Main
4.1 59 0
10 0
590.0 ft2
0
0
0.6
0
2 N
Exterior Concrete Block - Int Insul
Main
4.1 20 0
10 0
200.0 ft2
0
0
0.6
0
3 W
Exterior Concrete Block - Int Insul
Main
4.1 66 0
10 0
660.0 ft2
0
0
0.6
0
4 S
Exterior Concrete Block - Int Insul
Main
4.1 40 0
10 0
400.0 ft2
0
0.6
0
5 -
Garage Frame - Wood
Main
13 27 0
10 0
270.0 ft2
0
0.23
0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
N Insulated Main
None
.25
3
6 8
20 ft2
2
- Insulated Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
E
1 Vinyl Low-E Double
Yes
0.33 0.23 N
6.9 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
2
E
1 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
3
N
2 Vinyl Low-E Double
Yes
0.33 0.31 N
7.1 ft2
9 ft 0 in
0 It 6 in
None
None
4
N
2 Vinyl Low-E Double
Yes
0.33 0.21 N
16.2 ft2
1 ft 0 in
3 ft 11 in
None
Exterior 5
5
N
2 Vinyl Low-E Double
Yes
0.33 0.21 N
16.2 ft2
1 ft 0 in
5 ft 4 in
None
Exterior 5
6
N
2 Vinyl Low-E Double
Yes
0.33 0.31 N
13.3 ft2
9 ft 0 in
2 ft 0 in
None
None
7
W
3 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
8
S
4 Vinyl Low-E Double
Yes
0.55 0.7 N
17.8 ft2
11 ft 5 in
0 ft 6 in
None
Exterior 5
9
S
4 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
10
S
4 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
11 ft 6 in
0 ft 6 in
None
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
596 ft2 596 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000444
2123.3 116.49 218.7
.1381
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5 34.6 kBtu/hr
1
sys#1
7/16/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ft2
DUCTS
---- Supply --
---- Return --
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 364 ftz
Main
91 ft2 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan j Feb
HeatinJan f X] Feb
Mar
Mar
A r
f Apr f
Jul
May JunJul
Ma rl
Jun ri
Au
AuSep
ri
Se
ri
Oct
Oct
Nov
NovDecVentin
Dec
Jan [ ] Feb
X
X Mar
[X] A r [
Ma Jun Jul
Aug
Se [X]
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78 80
80
80
80
PM
80
80 78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78 78
78
78
78
PM
78
78 78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
7/16/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz
7. Windows"
Description
a. U-Factor:
Dbl, U=0.33
SHGC:
SHGC=0.23
b. U-Factor:
Dbl, U=0.33
SHGC:
SHGC=0.21
c. U-Factor:
Dbl, U=0.33
SHGC:
SHGC=0.31
d. U-Factor:
other (see details)
SHGC:
other (see details)
Area Weighted Average
Overhang Depth:
Area Weighted Average
SHGC:
8. Skylights
Description
a. U-Factor(AVG):
N/A
SHGC(AVG):
N/A
8705 Merano Avenue, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Detached
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
1
c. N/A
4
d. N/A
No
11. Ceiling Type and insulation level
a. Under Attic (Vented)
1820
b. Knee Wall (Vented)
Area
c. N/A
168.74 ftz
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Main, AH: Main
32.38 ftz
13. Cooling systems
20.42 ftz
a. Central Unit
17.78 ftz
4.067 ft.
0.269
Area
ftz
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ftz
b. N/A R= ftz
c. N/A R= ftz
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signatu!�� Date:
Address of New Home:
City/FL Zip:
Insulation Area
R=4.1 1850.00 ftz
R=13.0 270.00 ftZ
R=
ftz
R=
ftz
Insulation Area
R=30.0
1820.00 ftz
R=19.0
80.00 ftz
R=
ftz
R ftz
6 364
kBtu/hr
Efficiency
35.0
SEER:16.00
kBtu/hr Efficiency
34.6 HSPF:8.50
Cap: 40 gallons
EF: 0.94
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/16/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1