HomeMy WebLinkAboutLetter- Truss Design258 Southhall Lane, Suite 200 fiF;Maitland, Florida 32751 DP: (321) 972-0491 1 F: (407) 880-2304 1 E: info@fdseng.com 81 W.bsite: www.fdseng.com ENGINEERING ASSOCIATES November 22, 2021 Building Department Ref: Adams Homes Lot: Lot 60 Blk.1 Subdivision: Fort Pierce - Waterstone Address: 8705 Merano Ave. Model: 1820 B LHG KA # 21-10144 Truss Company: Builders First Source Date of drawings: 8/10/21 Job No.: 2866237 Wind Speed: 160 Exposure: C Truss Engineer: Joaquin Velez To whom it may concern, Pill! t'v � REVIEWED FOR CODE COMPLIANCE S ®e LUCiE COUNT EOCC We have reviewed the truss design package for the project referenced above. This truss package complies with the original design intent and the underlying structure will accommodate all indicated loads. We approve the truss package without comment based upon the truss layout and truss profiles supplied to us by the Truss Company with truss profiles sealed by the Truss Engineer. Please note, this review is only for general conformance with the design concept of the project. Contractor or sub -contractor is responsible for matching all structural components and details shown in the construction documents. Contractor or sub -contractor is also responsible for confirming all quantities and dimensions; selecting appropriate fabrication processes and techniques; and coordinating work with all other trades. Note: Truss ID's may vary. If you have any questions, please do not hesitate to call. Sincerely, 11/22/2021 11/22/2021 Carl A. Brown, P.E. Scott Lewkowski, P.E. FL. # 56126 FL. #78750 FDS Engineering Associates, A TSG Company "Your Building Code Experts" 11AI 71111881 °A° e°•'� �s F Ai3 L � �m�' vJ .•��CE/V ppo No 8786 'N b �n : ST ; 888888d&i7B�ti+�? Luis Pablo To es, P.E. FL. # 87864 CONNECTORS SCHEDULE ROOF TRUSS QT ID MODEL ROOF UPLIFT SYM 0 A-11 LUS24 / JUS24 895 / 835 490 /510 1 1L- 7 A HTU26/ THD26 3600 / 3470 1555 / 2330 'w 0 B HTU28 / THD28 4680 / 5040 2140 / 2330 1LB 0 C HTU26-2 / THD26-2 3600 / 3355 2175 / 2340 1 Lc 0 D HTU28-2 / THD28-2 14680 / 5005 3485 / 2596 1 11) 0 E HGUS26-2 / THDH26-2 5320 / 5245 2155 / 2340 11E 0 F 11 HGUS28-2 / THDH28-2 7460 / 8025 113235 / 3330 1 iF 0 G HGUS26-3 / THDH26-3 5230 / 5245 2155 / 2340 J to 0 H HGUS28-3 / THDH28-3 7460 / 7835 3235 / 4370 1 w 0 J THJA26 / HJC26 9100 / 8990 4095 / 4370 1 W 3 X 8 NOP ❑+ Reviewed and Approved ❑ Revise and Resubmit ❑ Reviewed with Notations ❑ Not Reviewed (see explanation) Corrections or comments made on equipment submittals or shop drawings during this review do not relieve contractor from compliance with requirements of the drawings and specifications. This check is only for review of general conformance with the concept of the project and general compliance with the information given in the contract documents. The contractor is responsible for confirming and correlating all quantities and dimensions; selecting fabrication processes and techniques of construction; coordinating his work with that of all other trades and performing his work in a safe and satisfactory manner FDS ENGINEERING ASSOCIATES Date: 11/22/2021 By: ES Submittal No.: ProjectNo.: 21-10144 ProjectEng.: Luis Torres Project Name: Adams Homes - Fort Pierce - Waterston - Lot 60 Blk 1 , VERIFY ALL DIMENSIONS AM CEILING CONDITIONS PRIOR TO APPROVAL SOME COUNG FRANJNG REOURED IN FIELD BY SUMER MAIN YAND FORCE RESISTING SYS WCC HYBRID WINO ASM746 ENCLOSED EXPOSURE CATEGORY C OCCUPANCY CATEGORY MID LOAD 160 MM 1N0ID IMPORTANCE FACTORIA6 TRUSSES HAVE BEEN DESIGNED FOR A 10.0 PSF BORON CHORD LNE LOAD NONCONCIXUiENT WRH ANY OTHER LNE LOADS ROOF LOADING FLOOR LOADING TCLL• 20 PSF TCLL• 40 PSF TCDL: 07 PSF TCDL: 10 PSF BCDL: 10 PSF BCDL• 6 PSF TOTAL: 37 PSF TOTAL: 65 PSF DURATION: 1.25 DURATION: 1.00 IMPORTANT This Drawing Must Be Approved And Returned Before Fabrication Will Begin. For Your Protection Check All Dimensions And Conditions Prior To Approval Of Plan. SIGNATURE BELOW INDICATES ALL NOTES AND DIMENSIONS HAVE BEEN ACCEPTED. By Date CAUTIONM DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRING TO THE ENGINEERING DRAWINGS AND BSCI-Bt SUMMARY SHEETS. ALL PERMANENT BRACING MUST BE IN PLACE PRIOR TO LOADING TRUSSES. (le. SHEATHING, SHINGLES, ETC.) ALL INTERIOR BEARING WALLS MUST BE IN PLACE PRIOR TO INSTALLING TRUSSES. REFER TO FINAL ENGINEERING SHEETS FOR THE FOLLOWING. 1) NUMBER OF GIRDER PLIES AND NAILING SCHEDULE 2) BEARING BLOCK REQUIREMENTS. 3) SCAB DETAILS (IF REQUIRED) 4) UPLIFT AND GRAVITY REACTIONS. WARNING Backcharges Will Not Be Accepted Regardless of Fault Without Prior Notification By Customer Within 48 Hours And Investigation By Builders First Source. NO EXECPTIONS. The General Contractor Is Responsible For All Connections Other Than Truss to Truss, Gable Shear Wall, And Connections. Temporary and Permanent Bracing, And Ceiling And Roof Diaphragm Connections. ROOF PITCH: 6112 CEILING PITCH: 3112 TOP CHORD SIZE: 2 X 4 BOTTOM CHORD SIZE: 2 X 4 OVERHANG LENGTH: 16" END CUT: Plumb CANTILEVER: — TRUSS SPACING: 24" BUILDING CODE: FBC2020 BEARING HEIGHT SCHEDULE Hatch Legend =W-0"bearing ®10'-0" bearing BUILDER: Adams Homes PROJECT: Single Family MODEL• 1820 B 3CAR A RESS: 8706 MERANO AVE T 1 BLOCK: 6011 SUBDIVISION: WATERSTONE CITY: FT PIERCE DRAWN BY: KSANCHEZ JOB ft : 2866237 DATE: 1 W0812021 1 SCALE: NTS PLAN DATE: 1 2021 REVISIONS: 1. 2. 3. 4. Buildersce'riblifing to Serve you better 4408 Airport Road Plant City, FL 33563 Ph.(813) 305.1300 Fax(813) 305,1301