HomeMy WebLinkAboutLetter- Truss Design258 Southhall Lane, Suite 200 D Maitland, Florida 32751 P: (321) 972-0491 1 F: (407) 880-2304 I E: info@fdseng.com Website: www.fdseng.com ENGINEERING ASSOCIATES November 30, 2021 Building Department Ref: Adams Homes Lot: Lot 34 Blk. Ph3 Subdivision: Fort Pierce - Waterstone Address: 8688 Waterstone Blvd. Model: 2265 3CF A RHG KA # 21-10559 Truss Company: Builders First Source Date of drawings: 9/14/21 Job No.: 2866970 Wind Speed: 160 Exposure: C Truss Engineer: Andrew Johnson To whom it may concern, We have reviewed the truss design package for the project referenced above. This truss package complies with the original design intent and the underlying structure will accommodate all indicated loads. We approve the truss package without comment based upon the truss layout and truss profiles supplied to us by the Truss Company with truss profiles sealed by the Truss Engineer. Please note, this review is only for general conformance with the design concept of the project. Contractor or sub -contractor is responsible for matching all structural components and details shown in the construction documents. Contractor or sub -contractor is also responsible for confirming all quantities and dimensions; selecting appropriate fabrication processes and t hni d d' t' rk with all other trades ec ques, an coor ma mg wo A a a 1 I 1 a p Note: Truss ID's may vary. If you have any questions, please do not hesitate to call. Sincerely, 11/30/2021 11/30/2021 Carl A. Brown, P.E. Scott Lewkowski, P.E. FL. # 56126 FL. #78750 FDS Engineering Associates, A TSG Company "Your Building Code Experts" %'; '%s ��. No 8 64 p`° TE pE 11 '�Q��B&63lilit6eh`®� Luis Pablo T rres, P.E. FL. # 87864 • U CONNECTORS SCHEDULE ROOF TRUSS QT ID MODEL ROOF UPLIFT SYM 0 1 A-11 LUS24 / JUS24 895 / 835 490 /610 ILA 6 A HTU26 / THD26 3600 / 3470 1555 / 2330 ILA 0 B HTU28 / THD28 4680 / 5040 2140 / 2330 IL- 0 C HTU26-2 / THD26-2 3600 / 3355 2175 / 2340 1 1 LC 0 D HTU28-2 / TH1328-2 4680 / 5005 3485 / 2595 1 1 La 0 E HGUS26-2 / THDH26-2 5320 / 5245 2155 / 2340 1 1 iE 0 F I HGUS28-2 / THDH28-2 7460 / 8025 3235 / 3330 1 1IF 0 G HGUS26-3 / THDH26-3 5230 / 5245 2155 / 2340 1 LG 0 H HGUS28-3 / THDH28-3 7460 / 7835 3235 / 4370 1 w 0 J THASR-1-29 / 9100 / 8990 4095 / 4370 1 Li 28 3 X 8 NOP 11 ID Reviewed and Approved ❑ Revise and Resubtrtit ❑ Reviewed with Notations ❑ Not Reviewed (see explanation) Corrections or comments made on equipment submittals or shop drawings during this review do not relieve contractor from compliance with requirements of the drawings and specifications. This check is only for review of general conformance with the concept of the project and general compliance with the information given in the contract documents. The contractor is responsible for confuting and correlating all quantities and dimensions; selecting fabrication processes and techniques of construction; coordinating his work with that of all other trades and performing his work in a safe and satisfactory manner FDS ENGINEERING ASSOCIATES Date: 11/30/2021 By. ES Submittal No.: Project No.: 21-10559 Project Eng.: Luis Torres Project Name: Adams Homes - Fort Pierce - Waterston - Lot 34 Blk Ph3 VERIFY ALL DIMENSIONS ANDCEIUNG CONLxBONS PRIOR TOAPPROVAL SON¢ CISLNG FRAMING REQUIRED IN nELD BY BUM -DER MAIN YAND FORCE RESISTING SYSTEM'Ct NYBRID WIND ASCE740 IMPORTANT ENCLOSED EXPOSURE CATEGORY C OCCUPANCY CATEGORY B This Drawing Must Be Approved And WHO LOAD 10 MPH Returned Before Fabrication Will MID IB1PORTANCE FACTORI.SG TRUSSES HAVE BEEN DESIGNED FORA 1GC PSF BOTTOM CHORD LNE LOAD Begin. For Your Protection Check All NONGONCURRENr Willi ANY OTHER LIVE LOADS Dimensions And Conditions Prior To Approval Of Plan. SIGNATURE BELOW INDICATES ALL ROOF LOADING FLOOR LOADING NOTES AND DIMENSIONS HAVE TOLL: 20 PSF TCLL: 40 PSF BEEN ACCEPTED. TCDL: 07 PSF TCDL• 10 PSF By �� BCDL: 10 PSF BCDL: 5 PSF TOTAL: 37 PSF TOTAL: 55 PSF DURATION: 1.25 DURATION: 1.00 CAUPON C!. DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRING TO THE ENGINEERING DRAWINGS AND BSCI-B1 SUMMARY SHEETS. ALL PERMANENT BRACING MUST BE IN PLACE PRIOR TO LOADING TRUSSES. (ie. SHEATHING, SHINGLES, ETC.) ALL INTERIOR BEARING WALLS MUST BE IN PLACE PRIOR TO INSTALLING TRUSSES. REFER TO FINAL ENGINEERING SHEETS FOR THE FOLLOWING. 1) NUMBER OF GIRDER PLIES AND NAILING SCHEDULE. 2) BEARING BLOCK REQUIREMENTS. 3) SCAB DETAILS (IF REQUIRED) 4) UPLIFT AND GRAVITY REACTIONS. WARNING Backcharges Will Not Be Accepted Regardless of Fault Without Prior Notification By Customer Within 48 Hours And Investigation By Builders First Source. NO EXECPTIONS. The General Contractor Is Responsible For All Connections Other Than Truss to Truss, Gable Shear Wall, And Connections. Temporary and Permanent Bracing, And Ceiling And Roof Diaphragm Connections. ROOF PITCH: 6112 CEILING PITCH: 0112 TOP CHORD SIZE: 2 X 4 BOTTOM CHORD SIZE: 2 X 4 OVERHANG LENGTH: 16" END CUT, Plumb CANTILEVER: — TRUSS SPACING: 24" BUILDING CODE: FBC2020 BEARING HEIGHT SCHEDULE Hatch Legend 11'4" BRG HGHT =9-9' BRG HGHT 10'-0" BRG HGHT BUILDER: Adams Homes PROJECT: Single Family 160 MODEL: 2266 A 3CAR 160 ADDRESS: 8688 WATERSTONE BLVD LOT /BLOCK: 341PH3 SUBDIVISION: WATERSTONE CITY: FT PIERCE DRAWN BY: K SANCHEZ JOB $: 2866970 DATE: 09/10/2021 SCALE: NTS PLAN DATE721)211 REVISIONS: 1.JAN 2021 (NEW CODE) 2. 3. 4. L•l171 J Combining to swve you bctter 4408 Airport Road Plant City, FL 33563 Ph. (813) 305-1300 Fax (813) 305-1301 • ►W