HomeMy WebLinkAboutLetter Of Truss Design258 Southhall Lane, Suite 200 fi;F D Maitland, Florida 32751 P: (321) 972-0491 1 F: (407) 880-2304 1 E: info@fdseng.com Website: www.fdseng.com ENGINEERING ASSOCIATES December 10, 2021 Building Department Ref: Adams Homes Lot: Lot 20 Ph.3 Subdivision: Fort Pierce - Waterstone Address: 8320 Amalfi Cir. Model: 2508 A RHG KA # 21-10552 Truss Company: Builders First Source Date of drawings: 9/14/21 Job No.: 2867272 Wind Speed: 160 Exposure: C Truss Engineer: Andrew Johnson To whom it may concern, copy opy We have reviewed the truss design package for the project referenced above. This truss package complies with the original design intent and the underlying structure will accommodate all indicated loads. We approve the truss package without comment based upon the truss layout and truss profiles supplied to us by the Truss Company with truss profiles sealed by the Truss Engineer. Please note, this review is only for general conformance with the design concept of the project. Contractor or sub -contractor is responsible for matching all structural components and details shown in the construction documents. Contractor or sub -contractor is also responsible for confirming all quantities and dimensions; selecting appropriate fabrication processes and techniques; and coordinating work with all other trades. Note: Truss ID's may vary. If you have any questions, please do not hesitate to call. Sincerely, 12/ 10/2021 Carl A. Brown, P.E. FL. # 56126 12/10/2021 Scott Lewkowski, P.E. FL. #78750 >>>33L9'd3Bdp�ff �BLO • �`O �d f tie \� GEN�4• •�J. ti v �• ems\ �• ••. m� • No 8786 • • m ►L z 0 s STAT OF Uro t, V' o Luis Pablo To s, P.E. FL. # 87864 FDS Engineering Associates, A TSG Company 'Your Building Code Experts" 60.00-00 14-00-00 23-08-00 21-00-00 I C1"C3 C C') Do Q r Q 0 EX OSE TO IND o ,o'y N_ Q co Q �_ Q LO Q 67 Q r U r� VC3 C5 °D 4-0 00 5 + +o + + + + 9" 0 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + t + + + + + + + + + + + + + + + + + + + + + + + + -40' CEIL4 G+H + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Lrp + vim N + + �+ t- + + d o + + + + o <F + �+ + + o+ 1 + m a+ + o+ +a+ + o + + o+ o + o + + + + o+ + + a+ + + + + + + + + + -00-00 + + -0 0 + + + + + + + + + + 2-00 + + 7-00-00 ID + + + + + + + + + + + + + + tJ + + + + + + + + + + + + + + + + + + + + + + + + E + + + + + + + + + + + + + + + + + + + + + + + + + 1} —m °- W + + + + + + + + + + + + + + + CJ + + + + + + + + + + + + + + + + + + o + + + + + + + + + + + + + + rn O + + + + + + + + + + + + + h + + + + + + + + + + + + + + + + + + + + W Iroi + + + + + + + + I- + I- + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + M m + + + + + + + + + @+ (D + + m+ _+_ m d] i+ + _ + � 0] IL + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + T + + + + + + + + + + 0'+C + + INCH + T, + + + + a 9 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + E7V \ + + + + + + + + + + + + + + 7 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + E7V N + + + + + F. + + + E7V m + +++ o r++++ + + + + + + + + + + +E7� E ALL o to DD + + + + + + + + g+ 4. + + + + + + B 3B 5 0 vaul 2 13 o9-1 C3 C1 m r U U C C e o o 13 3P o 0 OSE W N 13 U U W W (0) U 13 12-04-00 10-08-00 11-00-00 19 0 20 21 'r o 0 C5 C5 C3 3 14-04-00 6-08-00 C1 C1 U Di U U n W r W r• W n w- n W n' w r` W Ln U M U L�s 24-08-00 34-00-00 58-OB-00 I SIMPSON CONNECTOR SCHEDULE ROOF TRUSS QT ID MODEL ROOF UPLIFT SYMBOL 0 A` LUS24 895 490 1LA� 0 A HTU26 3600 1555 .1 LA 0 B HTU28 4680 2140 1l8 0 C HTU26-2 3600 2175 1 LC 0 D HTU28-2 4680 3485 1 w 0 E HGUS26-2 5320 12155 Ile 0 F HGUS28-2 7460 3235 1IF 0 G HGUS26-3 5230 2155 1 LG 0 H HGUS28-3 7460 3235 1 w 0 J THJA-26 9100 4095 1 W L.32__ 3X8NOP ❑+ Reviewed and Approved ❑ Revise and Resubmit ❑ Reviewed with Notations ❑ Not Reviewed (see explanation) Corrections or comments made on equipment submittals or shop drawings during this review do not relieve contractor from compliance with requirements of the drawings and specifications. This check is only for review of general conformance with the concept of the project and general compliance with the information given in the contract documents. The contractor is responsible for confirming and correlating all quantities and dimensions; selecting fabrication processes and techniques of construction; coordinating his work with that of all other trades and performing his work in a safe and satisfactory manner FDS ENGINEERING ASSOCIATES Date: 12/10/2021 By: BH Submittal No.: Project No.: 21-10552 Project Name: Adams Homes - Ft. Pierce - Lot 20 Ph.3 VERIFY ALLDIMEN SANDCERINGCONDITIONSPRIORTOAPFROVAL SOME CEILING FRANINO REQUIRED W FIELD BY BUILDER MAW W1= FORCE RESISTING SYSTEN 4 HYBWO VRNO ASCET-IS ENCLOSED EXPOSURE CATEGORY C OCCUPANCYCATEGORY It VA ND LOAD IN MM V41M IMPORTANCE FACTOR TAU TRUSSES HAVE BEEN DESIONED FORA 109 PSF BOTTOM WOW LNE LOAD NONCONCURRENTwnH ANY OnAER LNE LOADS ROOF LOADING FLOOR LOADING TCLL: 20 PSF TCLL: 40 PSF L TCDL: 07 PSF TCDL: 10 PSF BCDL: 10 PSF BCDL: 5 PSF TOTAL: 37 PSF TOTAL: 66 PSF DURATION: 1.26 DURATION: 1.00 CAUTION!!! DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRING TO THE ENGINEERING DRAWINGS AND BSCI-61 SUMMARY SHEETS. ALL PERMANENT BRACING MUST BE IN PLACE PRIOR TO LOADING TRUSSES. (10. SHEATHING, SHINGLES, ETC.) ALL INTERIOR BEARING WALLS MUST BE IN PLACE PRIOR TO INSTALLING TRUSSES. REFER TO FINAL ENGINEERING SHEETS FOR THE FOLLOWING. 1) NUMBER OF GIRDER PLIES AND NAILING SCHEDULE. 2) BEARING BLOCK REQUIREMENTS. 3) SCAB DETAILS (IF REQUIRED) 4) UPLIFT AND GRAVITY REACTIONS. WARNING Baekcharges Will Not Be Accepted Regardless of Fault Without Prior Notification By Customer Within 48 Hours And Investigation By Builders First Source. NO EXECPTIONS. The General Contractor Is Responsible For All Connections Other Than Truss to Truss, Gable Shear Wall, And Connections. Temporary and Permanent Bracing, And Ceiling And Roof Diaphragm Connections. ROOF PITCH: 6112 CEILING PITCH: 0112 TOP CHORD SIZE: 2 X 4 BOTTOM CHORD SIZE: 2X4 OVERHANG LENGTH: 16" END CUT: Plumb CANTILEVER: — TRUSS SPACING: 24" BUILDING CODE: FBC2020 BEARING HEIGHT SCHEDULE Hakh Legend kB'-010'— BRG WALL D' BRG WALL BUILDER: Adams Homes PROJECT: Single Family 160 MODEL: 2508 A 2CAR ADDRESS: 8320 AMALFI CIR LOT / BLOCK: 20/PH3 SUBDIVISION: WATERSTONE CITY: I FT PIERCE DRAWN KSANCHEZ JO 2867272 AT 08/10/2021 SCALE NTS PLAN DATE 2021 REVISIONS: Project Eng.: Luis T 1.DEC 2020 IMPORTANT This Drawing Must Be Approved And Returned Before Fabrication Will Begin. For Your Protection Check All Dimensions And Conditions Prior To Approval Of Plan. SIGNATURE BELOW INDICATES ALL NOTES AND DIMENSIONS HAVE BEEN ACCEPTED. By Date 4408 Airport Road Plant City, FL 33663 Ph.(813) 305-1300 Fax (813) 305-1301