HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 20 Block 3 Waterstone 2508 AGR
Builder Name: ADAMS HOMES
Street: 8320 Amalfi Circle
Permit Office:
City, State, Zip: Fort Pierce, FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type$1944.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1672.00 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
c. N/A
R=13.0 272.00 ft2
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2616.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2516.00 ft2
6. Conditioned floor area above grade (ft2) 2516
b. Knee Wall (Vented)
R=19.0 100.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(308.9 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 166.06 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.55 51.11 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.70
a. Central Unit
42.0 SEER:15.00
c. U-Factor: Dbl, U=0.33 38.54 ft2
SHGC: SHGCng
Area Weighted Average Overhang Depth: 6.539 ft.
D
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.314
a. Electric Heat Pump
42.0 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2516.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2516.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 70.53
Glass/Floor Area: 0.123
PASS
Total Baseline
Loads: 70.44
I hereby certify that the plans s cations covered
Revs of the plans and
FHB Sr '
this calculation are in compl' the Flori rgy
�'"
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: n7-2n-2021 Winn KPnmany
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy CG'pD.tiLV
OWNER/AGENT-" -
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house.
1:ILE COPY
7/20/2021 9:43 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Lot 20 Block 3 Waterstone 25 Bedrooms: 4
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 2516
Lot #
20 Phase 3
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
8320 Amalfi Circle
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days
Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2516 20128
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2516 20128 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0
2516 ftz ----
0.44 0 0.56
ROOF
/
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
V/ #
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2813 ftz 630 ftz Medium
N 0.85 N 0.85
No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2516 ftz N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2516 ft' 0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
100 ftz 0.11
Wood
7/20/2021 9:43 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
-
Height
Sheathing Framing Solar Below
o
1
N
Exterior
Concrete Block - Int Insul
Main
4.1 17
6
8 0
140.0 ft2
0
0 0.6
0
2
S
Exterior
Concrete Block - Int Insul
Main
4.1 34
6
8 0
276.0 ft2
0
0 0.6
0
3
W
Exterior
Concrete Block - Int Insul
Main
4.1 42
6
8 0
340.0 ft2
0
0 0.6
0
4
NW
Exterior
Concrete Block - Int Insul
Main
4.1 5
0
8 0
40.0 ft2
0
0 0.6
0
5
N
Exterior
Concrete Block - Int Insul
Main
4.1 20
0
8 0
160.0 ft2
0
0 0.6
0
6
-
Garage
Frame - Wood
Main
13 34
0
8 0
272.0 ft2
0
0.23 0.01
0
7
N
Exterior
Concrete Block - Int Insul
Main
4.1 18
0
8 0
144.0 ft2
0
0 0.6
0
8
W
Exterior
Concrete Block - Int Insul
Main
4.1 8
6
8 0
68.0 ft2
0
0 0.6
0
9
W
Exterior
Concrete Block - Int Insul
Main
4.1 6
0
8 0
48.0 ft2
0
0 0.6
0
10
E
Exterior
Concrete Block - Int Insul
Main
4.1 57
8
456.0 ft2
0 0.6
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
S
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 f12
WINDOWS
Orientation shown is the entered, Proposed orientation.
I/
Wall
Overhang
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
W
8
Vinyl Low-E Double
Yes
0.55 0.7
N
15.6 ft2
25 ft 0 in 0 ft 10 in
Drapes/blinds
None
2
E
10
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
3
S
2
Vinyl Low-E Double
Yes
0.33 0.31
N
7.5 ft2
13 ft 0 in
0 ft 6 in
None
None
4
S
2
Vinyl Low-E Double
Yes
0.33 0.31
N
13.3 ft2
13 ft 0 in
2 ft 10 in
None
None
5
S
2
Vinyl Low-E Double
Yes
0.35 0.26
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
6
S
2
Vinyl Low-E Double
Yes
0.33 0.21
N
38.5 ft2
1 ft 4 in
2 ft 0 in
Drapes/blinds
None
7
E
10
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
25 ft 0 in
0 ft 10 in
Drapes/blinds
None
8
W
3
Vinyl Low-E Double
Yes
0.33 0.23
N
9.8 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
9
W
3
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
10
NW
4
Vinyl Low-E Double
Yes
0.33 0.23
N
12.5 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
None
11
N
5
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
9 ft 10 in
0 ft 10 in
Drapes/blinds
None
12
N
5
Vinyl Low-E Double
Yes
0.33 0.23
N
16.7 ft2
7 ft2 in
0 ft4 in
Drapes/blinds
None
13
N
7
Vinyl Low-E Double
Yes
0.33 0.23
N
30.0 ft2
9 ft 10 in
0 ft 4 in
Drapes/blinds
None
14
N
5
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
1 ft 2 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
555 ft2 555 ft2
64 ft
8 ft
1
7/20/2021 9:43 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPI IT RI IMMAPV rl49=rW1 ICT 0=0n0T
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000356
2348.3 128.83 241.87 .1263
7
# System Type
Subtype
HEATING SYSTEM
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5 42 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 42 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ftz
DUCTS
/ ---- Supply ----
# Location R-Value Area
---- Return--- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1 Attic 6 503.2 ft
Main
125.8 ft Proposed Qn Main --- cfm 125.8 cfm 0.05 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
CoolingJan Feb Mar
Heatinf X� Jan Feb X Mar
Ventin [ Jan Feb X Mar
Ceiling Fans:
Se
f APr f IMay f Jun 4 Jul uSep
A r Ma X Jun X Jul Mug
u rl
[X] A r [ Ma [ Jun [ Jul Se [X]
Oct Nov
Oct Nov
Oct HX Nov
Dec
Dec
H Dec
7/20/2021 9:43 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
7
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
PM
66
68
66
68
66
66
66
68
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ftz
0 ft
0.3
Main
7/20/2021 9:43 AM
7.0.00 -
FlaRes202O
FBC 7th Edition (2020) Compliant Software
Page
5 of 5
T
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
8320 Amalfi Circle, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1672.00 W
b. Frame - Wood, Adjacent
R=13.0
272.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2516.00 ft2
6. Conditioned floor area (ft2)
2516
b. Knee Wall (Vented)
R=19.0
100.00 ft2
7. Windows** Description
Area
c. A
R=
ft2
a. U-Factor: Dbl, U=0.33
166.06 ft2
12. Ducts, location & insulation level
R ft2
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
b. U-Factor: Dbl, U=0.55
51.11 ft2
SHGC: SHGC=0.70
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.33
38.54 ft2
a. Central Unit
42.0 SEER:15.00
SHGC: SHGC=0.21
d. U-Factor: - other (see details)
53.21 ft2
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
6.539 ft.
a. Electric Heat Pump
42.0
HSPF:8.50
Area Weighted Average SHGC:
0.314
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2EF:0.94
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
2516.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder SiDate:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/20/2021 9:43 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1